DQR ID | Subject | Data Streams Affected |
---|---|---|
D040225.10 | SGP/TWR/C1 - Temperature Sensor Not Connected to Datalogger | sgp1twr10xC1.b1, sgp30twr10xC1.b1 |
D040225.11 | SGP/TWR/C1 - Some data incorrect during testing | sgp1twr10xC1.b1, sgp30twr10xC1.b1 |
D040225.14 | SGP/TWR/C1 - Tower Southeast Side Carriages Down for Work on the MFR | sgp1twr10xC1.b1, sgp30twr10xC1.b1 |
D040225.8 | SGP/TWR/C1 - Southeast Side Data Incorrect During Sensor Tests and Changeout | sgp1twr10xC1.b1, sgp30twr10xC1.b1 |
D040225.9 | SGP/TWR/C1 - Tower Southeast Side Carriages Not Connected | sgp1twr10xC1.b1, sgp30twr10xC1.b1 |
D040304.30 | SGP/TWR/C1 - Southeast Side RH Too Large | sgp1twr10xC1.b1, sgp30twr10xC1.b1 |
D040507.5 | SGP/TWR/C1 - Southeast Side Tower Measurements Incorrect; Power Cycled | sgp1twr10xC1.b1, sgp30twr10xC1.b1 |
D040813.1 | SGP/TWR/C1 - Southeast Side (10X datastream) Data Incorrect | sgp1twr10xC1.b1, sgp30twr10xC1.b1 |
D040830.4 | SGP/TWR/C1 - Tower SE Side T/RH/VP Incorrect During Maintenance | sgp1twr10xC1.b1, sgp30twr10xC1.b1 |
D041006.1 | SGP/TWR/C1 - Southeast 25 and 60 m T/RH/VP Incorrect | sgp1twr10xC1.b1, sgp30twr10xC1.b1 |
Start Date | Start Time | End Date | End Time |
---|---|---|---|
02/05/2004 | 1631 | 02/09/2004 | 1926 |
Subject: | SGP/TWR/C1 - Temperature Sensor Not Connected to Datalogger |
DataStreams: | sgp1twr10xC1.b1, sgp30twr10xC1.b1 |
Description: | One of the southeast side 25 m Temperature sensor leads was pulled out from the CR10X datalogger terminal strip. |
Measurements: | sgp1twr10xC1.b1:
sgp30twr10xC1.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
02/09/2004 | 2210 | 02/09/2004 | 2215 |
Subject: | SGP/TWR/C1 - Some data incorrect during testing |
DataStreams: | sgp1twr10xC1.b1, sgp30twr10xC1.b1 |
Description: | During testing of tower data wiring, the 60 m southeast side temperature and vapor pressure measurements were incorrect. |
Measurements: | sgp1twr10xC1.b1:
sgp30twr10xC1.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
02/13/2004 | 1751 | 02/13/2004 | 2138 |
Subject: | SGP/TWR/C1 - Tower Southeast Side Carriages Down for Work on the MFR |
DataStreams: | sgp1twr10xC1.b1, sgp30twr10xC1.b1 |
Description: | The tower southeast side T, RH, and VP measurements were incorrect while the carriages were down for work on the MFR. |
Measurements: | sgp1twr10xC1.b1:
sgp30twr10xC1.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
02/10/2004 | 1856 | 02/10/2004 | 2308 |
Subject: | SGP/TWR/C1 - Southeast Side Data Incorrect During Sensor Tests and Changeout |
DataStreams: | sgp1twr10xC1.b1, sgp30twr10xC1.b1 |
Description: | The met measurements were incorrect while the T/RH probes were being tested and then replaced. |
Measurements: | sgp1twr10xC1.b1:
sgp30twr10xC1.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
02/20/2004 | 1458 | 02/23/2004 | 1840 |
Subject: | SGP/TWR/C1 - Tower Southeast Side Carriages Not Connected |
DataStreams: | sgp1twr10xC1.b1, sgp30twr10xC1.b1 |
Description: | The tower southeast side carriages were not connected. Met data from the southeast side is therefore incorrect during the stated period. |
Measurements: | sgp1twr10xC1.b1:
sgp30twr10xC1.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
08/15/2003 | 1345 | 02/10/2004 | 2310 |
Subject: | SGP/TWR/C1 - Southeast Side RH Too Large |
DataStreams: | sgp1twr10xC1.b1, sgp30twr10xC1.b1 |
Description: | The T/RH probes installed on the 25 m and 60 m levels of the southeast side of the tower on 8/15/03 gave RH readings that were too large for RH above 65%. The difference between the west and southeast side RH was within the combined accuracies of the sensors up to about 80% RH. Above 80% RH the southeast side RH was much larger, with the difference increasing to 10% larger (or more) at 100% RH. The vapor pressure from the southeast side (calculated with RH) was also too large. The probes were replaced on 2/10/04 and the two sides of the tower now agree fairly well, with RH not exceeding 100% during saturation. |
Measurements: | sgp1twr10xC1.b1:
sgp30twr10xC1.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
04/15/2004 | 2105 | 04/15/2004 | 2154 |
Subject: | SGP/TWR/C1 - Southeast Side Tower Measurements Incorrect; Power Cycled |
DataStreams: | sgp1twr10xC1.b1, sgp30twr10xC1.b1 |
Description: | Measurements from the Southeast side 10X met system were incorrect; power was recycled. |
Measurements: | sgp1twr10xC1.b1:
sgp30twr10xC1.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
07/21/2004 | 1527 | 07/21/2004 | 1613 |
Subject: | SGP/TWR/C1 - Southeast Side (10X datastream) Data Incorrect |
DataStreams: | sgp1twr10xC1.b1, sgp30twr10xC1.b1 |
Description: | The data from the southeast side of the tower (10X datastream) was incorrect for a short period. |
Measurements: | sgp1twr10xC1.b1:
sgp30twr10xC1.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
08/05/2004 | 1412 | 08/05/2004 | 1451 |
Subject: | SGP/TWR/C1 - Tower SE Side T/RH/VP Incorrect During Maintenance |
DataStreams: | sgp1twr10xC1.b1, sgp30twr10xC1.b1 |
Description: | The SE side elevator was lowered for maintenance on other instruments. T/RH/VP data are incorrect during this period. |
Measurements: | sgp1twr10xC1.b1:
sgp30twr10xC1.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
09/27/2004 | 1438 | 09/27/2004 | 2056 |
Subject: | SGP/TWR/C1 - Southeast 25 and 60 m T/RH/VP Incorrect |
DataStreams: | sgp1twr10xC1.b1, sgp30twr10xC1.b1 |
Description: | The SE carriages were down for annual T/RH checks/replacements. |
Measurements: | sgp1twr10xC1.b1:
sgp30twr10xC1.b1:
|