Data Quality Reports for Session: 100707 User: danahe Completed: 07/25/2006


TABLE OF CONTENTS

DQR IDSubjectData Streams Affected
D030312.10SGP/MWR/C1 - Intermittent Negative Sky Brightness TemperaturessgpmwrlosC1.a1, sgpmwrlosC1.b1, sgp1mwravgC1.c1, sgp5mwravgC1.c1
D050722.1SGP/MWR/C1 - REPROCESS - Revised Retrieval CoefficientssgpmwrlosC1.a1, sgpmwrlosC1.b1, sgpmwrtipC1.a1, sgp1mwravgC1.c1, sgp5mwravgC1.c1,
sgpqmemwrcolC1.c1


DQRID : D030312.10
Start DateStart TimeEnd DateEnd Time
11/17/1999180007/31/20022034
Subject:
SGP/MWR/C1 - Intermittent Negative Sky Brightness Temperatures
DataStreams:sgpmwrlosC1.a1, sgpmwrlosC1.b1, sgp1mwravgC1.c1, sgp5mwravgC1.c1
Description:
Several related and recurring problems with the SGP MWRs have been
reported dating back to 1999.  These problems were due to the
occurrence of blackbody signals (in counts) that were half of those
expected. The symptoms included noisy data (especially at Purcell),
spikes in the data (especially at Vici), negative brightness
temperatures, and apparent loss of serial communication between the
computer and the radiometer, which results in a self-termination of the
MWR program (especially at the CF).

Because these all initially appeared to be hardware-related problems,
the instrument mentor and SGP site operations personnel (1) repeatedly
cleaned and replaced the fiber optic comm. components, (2) swapped
radiometers, (3) sent radiometers back to Radiometrics for evaluation
(which has not revealed any instrument problems), and (4) reconfigured
the computer's operating system.  Despite several attempts to isolate
and correct it, the problem persisted.

It became apparent that some component of the Windows98 configuration
conflicted with the DOS-based MWR program or affected the serial port
or the contents of the serial port buffer. This problem was finally
corrected by upgrading the MWR software with a new Windows-compatible
program.
Measurements:sgp5mwravgC1.c1:
  • Mean total liquid water amount along LOS path(liq)
  • Mean 23.8 GHz sky brightness temperature(tbsky23)
  • Mean total water vapor amount along LOS path(vap)
  • Mean 31.4 GHz sky brightness temperature(tbsky31)

sgpmwrlosC1.b1:
  • Mean 31.4 GHz sky brightness temperature(tbsky31)
  • Mean total liquid water amount along LOS path(liq)
  • Mean total water vapor amount along LOS path(vap)
  • Mean 23.8 GHz sky brightness temperature(tbsky23)

sgp1mwravgC1.c1:
  • Mean 23.8 GHz sky brightness temperature(tbsky23)
  • Mean total liquid water amount along LOS path(liq)
  • Mean total water vapor amount along LOS path(vap)
  • Mean 31.4 GHz sky brightness temperature(tbsky31)

sgpmwrlosC1.a1:
  • Mean total water vapor amount along LOS path(vap)
  • Mean 23.8 GHz sky brightness temperature(tbsky23)
  • Mean 31.4 GHz sky brightness temperature(tbsky31)
  • Mean total liquid water amount along LOS path(liq)


Back To Table of Contents

DQRID : D050722.1
Start DateStart TimeEnd DateEnd Time
04/16/2002200006/28/20052300
Subject:
SGP/MWR/C1 - REPROCESS - Revised Retrieval Coefficients
DataStreams:sgpmwrlosC1.a1, sgpmwrlosC1.b1, sgpmwrtipC1.a1, sgp1mwravgC1.c1, sgp5mwravgC1.c1,
sgpqmemwrcolC1.c1
Description:
IN THE BEGINNING (June 1992), the retrieval coefficients used to derive the precipitable 
water vapor (PWV) and liquid water path (LWP) from the MWR brightness temperatures were 
based on the Liebe and Layton (1987) water vapor and oxygen absorption model and the Grant 
(1957) liquid water absorption model.  

Following the SHEBA experience, revised retrievals based on the more recent Rosenkranz 
(1998) water vapor and oxygen absorption models and the Liebe (1991) liquid waer absorption 
model were developed.  The Rosenkranz water vapor absorption model resulted a 2 percent 
increase in PWV relative to the earlier Liebe and Layton model.  The Liebe liquid water 
absorption model decreased the LWP by 10% relative to the Grant model.  However, the 
increased oxygen absorption caused a 0.02-0.03 mm (20-30 g/m2) reduction in LWP, which was 
particularly significant for low LWP conditions (i.e. thin clouds encountered at SHEBA).

Recently, it has been shown (Liljegren, Boukabara, Cady-Pereira, and Clough, TGARS v. 43, 
pp 1102-1108, 2005) that the half-width of the 22 GHz water vapor line from the HITRAN 
compilation, which is 5 percent smaller than the Liebe and Dillon (1969) half-width used in 
Rosenkranz (1998), provided a better fit to the microwave brightness temperature 
measurements at 5 frequencies in the range 22-30 GHz, and yielded more accurate retrievals.  
Accordingly, revised MWR retrieval coefficients have been developed using MONORTM, which 
utilizes the HITRAN compilation for its spectroscopic parameters.  These new retrievals 
provide 3 percent less PWV and 2.6 percent greater LWP than the previous retrievals based on 
Rosenkranz (1998).

Although the MWR data will be reprocessed to apply the new monortm-based retrievals, for 
most purposes it will be sufficient to correct the data using the following factors:

PWV_MONORTM = 0.9695 * PWV_ROSENKRANZ
LWP_MONORTM = 1.026  * LWP_ROSENKRANZ

The Rosenkranz-based retrieval coefficients became active as follows (BCR 456):
SGP/C1 (Lamont)     4/16/2002, 2000
SGP/B1 (Hillsboro)  4/12/2002, 1600
SGP/B4 (Vici)       4/15/2002, 2300
SGP/B5 (Morris)     4/15/2002, 2300
SGP/B6 (Purcell)    4/16/2002, 2200
SGP/E14(Lamont)     4/16/2002, 0000
NSA/C1 (Barrow)     4/25/2002, 1900 
NSA/C2 (Atqasuk)    4/18/2002, 1700
TWP/C1 (Manus)      5/04/2002, 0200
TWP/C2 (Nauru)      4/27/2002, 0600
TWP/C3 (Darwin)     inception

The MONORTM-based retrieval coefficients became active as follows (BCR 984):

SGP/C1 (Lamont)     6/28/2005, 2300
SGP/B1 (Hillsboro)  6/24/2005, 2100
SGP/B4 (Vici)       6/24/2005, 2100
SGP/B5 (Morris)     6/24/2005, 2100
SGP/B6 (Purcell)    6/24/2005, 1942
SGP/E14(Lamont)     6/28/2005, 2300
NSA/C1 (Barrow)     6/29/2005, 0000 
NSA/C2 (Atqasuk)    6/29/2005, 0000
TWP/C1 (Manus)      6/30/2005, 2100
TWP/C2 (Nauru)      6/30/2005, 2100
TWP/C3 (Darwin)     6/30/2005, 2100
PYE/M1 (Pt. Reyes)  4/08/2005, 1900**

** At Pt. Reyes, the original retrieval coefficients implemented in March 2005 were based 
on a version of the Rosenkranz model that had been modified to use the HITRAN half-width 
at 22 GHz and to be consistent with the water vapor continuum in MONORTM.  These 
retrievals yield nearly identical results to the MONORTM retrievals.  Therefore the Pt. Reyes 
data prior to 4/08/2005 may not require reprocessing.
Measurements:sgpmwrtipC1.a1:
  • Total liquid water along zenith path using tip-derived brightness temperatures(liqtip)
  • Total water vapor along zenith path using tip-derived brightness temperatures(vaptip)

sgp5mwravgC1.c1:
  • Mean total water vapor amount along LOS path(vap)
  • Mean total liquid water amount along LOS path(liq)

sgpmwrlosC1.b1:
  • Mean total water vapor amount along LOS path(vap)
  • Mean total liquid water amount along LOS path(liq)

sgp1mwravgC1.c1:
  • Mean total liquid water amount along LOS path(liq)
  • Mean total water vapor amount along LOS path(vap)

sgpqmemwrcolC1.c1:
  • Ensemble average for MWR vapor in window centered about balloon release(mean_vap_mwr)
  • Ensemble average for MWR liquid in window centered about balloon release(mean_liq_mwr)

sgpmwrlosC1.a1:
  • Mean total liquid water amount along LOS path(liq)
  • Mean total water vapor amount along LOS path(vap)


Back To Table of Contents



END OF DATA