Data Quality Reports for Session: 101256 User: gaun Completed: 08/23/2006


TABLE OF CONTENTS

DQR IDSubjectData Streams Affected
D030114.1SGP/SONDE/C1 - Bad RH DatasgpsondewnpnC1.a1, sgpsondewnpnC1.b1
D030122.1SGP/SONDE/C1 - Broken temperature sensor SGP/CF soundingsgpsondewnpnC1.a1, sgpsondewnpnC1.b1
D030206.5SGP/SONDE/C1 - Bad temperature/RHsgpsondewnpnC1.a1, sgpsondewnpnC1.b1
D030330.1SGP/Sonde/C1 - Bad temperature, RHsgpsondewnpnC1.a1, sgpsondewnpnC1.b1
D030409.1SGP/Sonde/C1 - Bad RH in soundingsgpsondewnpnC1.a1, sgpsondewnpnC1.b1
D030411.1SGP/Sonde/C1 - Sondes launched an hour earlysgpsondewnpnC1.00, sgpsondewnpnC1.a1, sgpsondewnpnC1.b1
D030411.2SGP/Sonde/C1 - Incorrect surface temperature on CF soundingsgpsondewnpnC1.a1, sgpsondewnpnC1.b1
D030411.3SGP/Sonde/C1 - Failed Sonde Launches due to Antenna problemssgpsondeC1.00, sgplssondeC1.c1, sgpsondewnpnC1.a1, sgpsondewnpnC1.b1
D030419.2SGP/SONDE/C1 - Broken Temperature SensorsgpsondewnpnC1.a1, sgpsondewnpnC1.b1
D030427.1SGP/SONDE/C1 - Broken temperature sensorsgpsondewnpnC1.a1, sgpsondewnpnC1.b1
D030507.3SGP/SONDE/C1 - Broken temperature sensorssgpsondewnpnC1.a1, sgpsondewnpnC1.b1
D030614.1SGP/SONDE/C1 - Broken temperature sensorsgpsondewnpnC1.a1, sgpsondewnpnC1.b1
D030707.7SGP/SONDE/C1 - Incorrect surface RH value.sgpsondewnpnC1.a1, sgpsondewnpnC1.b1
D030722.1SGP/SONDE/C1 - Broken temperature sensorsgpsondewnpnC1.a1, sgpsondewnpnC1.b1
D030807.1SGP/SONDE/C1 - A few bad temperature values at the beginning of the soundingsgpsondewnpnC1.a1, sgpsondewnpnC1.b1
D031112.1SGP/SONDE/C1 - Broken temperature sensorsgpsondewnpnC1.b1
D040127.2SGP/SONDE/C1 - Bad RH DatasgpsondewnpnC1.b1
D040219.1SGP/SONDE/C1 - Bad RH DatasgpsondewnpnC1.b1
D040219.2SGP/SONDE/C1 - Surface pressure incorrectsgpsondewnpnC1.b1
D040223.1SGP/SONDE/C1 - Broken temperature sensorsgpsondewnpnC1.b1
D040301.1SGP/SONDE/C1 - Broken temperature sensorsgpsondewnpnC1.b1
D040415.2SGP/SONDE/C1 - Temperature sensor broke high into the soundingsgpsondewnpnC1.b1
D041005.1SGP/SONDE/C1 - Incorrect surface temperaturesgpsondewnpnC1.b1
D041013.4SGP/SONDE/C1 - Scheduled Soundings MissedsgpsondeC1.00, sgpsondewnpnC1.b1
D050201.1SGP/SONDE/C1 - Possibly bad pressure sensor or operator data entry errorsgpsondewnpnC1.b1
D050421.5SGP/SONDE/C1 - Surface pressure incorrectsgpsondewnpnC1.b1
D050510.1SGP/SONDE/C1 - Surface pressure bad and other data noisysgpsondewnpnC1.b1
D050510.2SGP/SONDE/C1 - Surface pressure incorrectsgpsondewnpnC1.b1
D050603.4SGP/SONDE/C1 - Surface pressure incorrectsgpsondewnpnC1.b1
D050725.1SGP/SONDE/C1 - Bad RH DatasgpsondewnpnC1.b1
D050811.5SGP/SONDE/C1 - Bad T/RH and surface P.sgpsondewnpnC1.b1
D050912.2SGP/SONDE/C1 - Temperature/RH incorrectsgplssondeC1.c1, sgpsondewnpnC1.b1
D051027.1SGP/SONDE/C1 - Bad RH DatasgpsondewnpnC1.b1
D051121.1SGP/SONDE/C1 - Sonde RH values incorrectsgpsondewnpnC1.b1
D060303.1SGP/SONDE/C1 - DigiCORAIII failed, replaced with S01/S02 launchessgpsondeC1.00, sgpsondewnpnC1.b1


DQRID : D030114.1
Start DateStart TimeEnd DateEnd Time
01/11/2003053601/11/20030551
Subject:
SGP/SONDE/C1 - Bad RH Data
DataStreams:sgpsondewnpnC1.a1, sgpsondewnpnC1.b1
Description:
The RH values during the first 15 minutes of this sounding oscillate between reasonable 
values and near-zero values.  The oscillation is irregular and seems to be related to 
failure of the RH sensor heating process.  I have informed Vaisala of the problem and provided 
raw data files to them for analysis.
Measurements:sgpsondewnpnC1.a1:
  • Relative humidity scaled, by total column amount from MWR(rh)
  • Surface dew point temperature(dp)

sgpsondewnpnC1.b1:
  • Surface dew point temperature(dp)
  • Relative humidity scaled, by total column amount from MWR(rh)


Back To Table of Contents

DQRID : D030122.1
Start DateStart TimeEnd DateEnd Time
01/19/2003113401/19/20031259
Subject:
SGP/SONDE/C1 - Broken temperature sensor SGP/CF sounding
DataStreams:sgpsondewnpnC1.a1, sgpsondewnpnC1.b1
Description:
The radiosonde temperature sensor apparently broke during launch.  This results in bad 
temperature, dew point, and rh data.
Measurements:sgpsondewnpnC1.a1:
  • Dry-Bulb Temperature(tdry)
  • Relative humidity scaled, by total column amount from MWR(rh)
  • Surface dew point temperature(dp)

sgpsondewnpnC1.b1:
  • Surface dew point temperature(dp)
  • Dry-Bulb Temperature(tdry)
  • Relative humidity scaled, by total column amount from MWR(rh)


Back To Table of Contents

DQRID : D030206.5
Start DateStart TimeEnd DateEnd Time
02/02/2003173202/02/20031832
Subject:
SGP/SONDE/C1 - Bad temperature/RH
DataStreams:sgpsondewnpnC1.a1, sgpsondewnpnC1.b1
Description:
The temperature sensor broke shortly after launch.  All temperature and RH-related data 
are incorrect.
Measurements:sgpsondewnpnC1.a1:
  • Dry-Bulb Temperature(tdry)
  • Relative humidity scaled, by total column amount from MWR(rh)
  • Surface dew point temperature(dp)

sgpsondewnpnC1.b1:
  • Surface dew point temperature(dp)
  • Dry-Bulb Temperature(tdry)
  • Relative humidity scaled, by total column amount from MWR(rh)


Back To Table of Contents

DQRID : D030330.1
Start DateStart TimeEnd DateEnd Time
03/18/2003113203/18/20031322
03/20/2003113103/20/20031140
03/20/2003173103/20/20031904
Subject:
SGP/Sonde/C1 - Bad temperature, RH
DataStreams:sgpsondewnpnC1.a1, sgpsondewnpnC1.b1
Description:
These three soundings all show the effects of a temperature sensor broken at launch.  The 
temperature, RH, dew-point values all are incorrect.
Measurements:sgpsondewnpnC1.a1:
  • Dry-Bulb Temperature(tdry)
  • Relative humidity scaled, by total column amount from MWR(rh)
  • Surface dew point temperature(dp)

sgpsondewnpnC1.b1:
  • Surface dew point temperature(dp)
  • Dry-Bulb Temperature(tdry)
  • Relative humidity scaled, by total column amount from MWR(rh)


Back To Table of Contents

DQRID : D030409.1
Start DateStart TimeEnd DateEnd Time
04/06/2003114404/06/20031203
Subject:
SGP/Sonde/C1 - Bad RH in sounding
DataStreams:sgpsondewnpnC1.a1, sgpsondewnpnC1.b1
Description:
The RH sensor heating circuit was out of synch from about 400 sec after launch until the 
circuit was turned off whent he sounding temperature reached approximately 233 degK (-40 
degC) about 1500 sec after launch.  During this time period the reported RH oscillates 
between reasonable values and near-zero values.
Measurements:sgpsondewnpnC1.a1:
  • Relative humidity scaled, by total column amount from MWR(rh)
  • Surface dew point temperature(dp)

sgpsondewnpnC1.b1:
  • Surface dew point temperature(dp)
  • Relative humidity scaled, by total column amount from MWR(rh)


Back To Table of Contents

DQRID : D030411.1
Start DateStart TimeEnd DateEnd Time
04/06/2003220004/07/20030700
Subject:
SGP/Sonde/C1 - Sondes launched an hour early
DataStreams:sgpsondewnpnC1.00, sgpsondewnpnC1.a1, sgpsondewnpnC1.b1
Description:
It looks like someone forgot to set his/her clock ahead.  The sounding that should have 
been done at 23:30 UTC on 4/6 was done at 22:38 and the following sounding, which should 
have been done at 0530 on 4/7 was done at 04:31.  The subsequent soundings all are done at 
the correct times.
Measurements:sgpsondewnpnC1.00:
  • Raw data stream - documentation not supported(Raw data stream - documentation not supported)

sgpsondewnpnC1.a1:
  • surface wind speed(wspd)
  • altitude above sea levelaltunits(alt)
  • model meridional wind velocity(v_wind)
  • Time offset from base_time(base_time)
  • Relative humidity scaled, by total column amount from MWR(rh)
  • Ascent Rate(asc)
  • Wind Direction(deg)
  • Wind Status(wstat)
  • model zonal wind velocity(u_wind)
  • Surface dew point temperature(dp)
  • Dry-Bulb Temperature(tdry)
  • Time offset of tweaks from base_time(time_offset)
  • north latitude for all the input platforms.(lat)
  • east longitude for all the input platforms.(lon)
  • pressure at constant pressure surface(pres)

sgpsondewnpnC1.b1:
  • surface wind speed(wspd)
  • model zonal wind velocity(u_wind)
  • north latitude for all the input platforms.(lat)
  • Ascent Rate(asc)
  • east longitude for all the input platforms.(lon)
  • Time offset of tweaks from base_time(time_offset)
  • model meridional wind velocity(v_wind)
  • altitude above sea levelaltunits(alt)
  • Surface dew point temperature(dp)
  • Time offset from base_time(base_time)
  • Relative humidity scaled, by total column amount from MWR(rh)
  • pressure at constant pressure surface(pres)
  • Wind Direction(deg)
  • Wind Status(wstat)
  • Dry-Bulb Temperature(tdry)


Back To Table of Contents

DQRID : D030411.2
Start DateStart TimeEnd DateEnd Time
04/06/2003223804/06/20032238
Subject:
SGP/Sonde/C1 - Incorrect surface temperature on CF sounding
DataStreams:sgpsondewnpnC1.a1, sgpsondewnpnC1.b1
Description:
It appears that the operator entered an incorrect value for surface temperature.  Rather 
than 43.2 degC in the file, the value is most likely 19. degC (thwaps reading 19.4, first 
sonde reading aloft 18.6).
Measurements:sgpsondewnpnC1.a1:
  • Dry-Bulb Temperature(tdry)

sgpsondewnpnC1.b1:
  • Dry-Bulb Temperature(tdry)


Back To Table of Contents

DQRID : D030411.3
Start DateStart TimeEnd DateEnd Time
04/01/2003173004/01/20031930
04/02/2003053004/02/20030730
04/02/2003113004/02/20031330
Subject:
SGP/Sonde/C1 - Failed Sonde Launches due to Antenna problems
DataStreams:sgpsondeC1.00, sgplssondeC1.c1, sgpsondewnpnC1.a1, sgpsondewnpnC1.b1
Description:
These sonde launches where unsuccessful due to problems
with the antenna configuration resulting in signal loss
before the launch.
Measurements:sgpsondewnpnC1.a1:
  • surface wind speed(wspd)
  • model meridional wind velocity(v_wind)
  • altitude above sea levelaltunits(alt)
  • Time offset from base_time(base_time)
  • Relative humidity scaled, by total column amount from MWR(rh)
  • Ascent Rate(asc)
  • model zonal wind velocity(u_wind)
  • Wind Status(wstat)
  • Wind Direction(deg)
  • Surface dew point temperature(dp)
  • Dry-Bulb Temperature(tdry)
  • Time offset of tweaks from base_time(time_offset)
  • north latitude for all the input platforms.(lat)
  • east longitude for all the input platforms.(lon)
  • pressure at constant pressure surface(pres)

sgpsondewnpnC1.b1:
  • model zonal wind velocity(u_wind)
  • surface wind speed(wspd)
  • north latitude for all the input platforms.(lat)
  • Ascent Rate(asc)
  • east longitude for all the input platforms.(lon)
  • Time offset of tweaks from base_time(time_offset)
  • model meridional wind velocity(v_wind)
  • altitude above sea levelaltunits(alt)
  • Surface dew point temperature(dp)
  • Time offset from base_time(base_time)
  • Relative humidity scaled, by total column amount from MWR(rh)
  • pressure at constant pressure surface(pres)
  • Wind Direction(deg)
  • Wind Status(wstat)
  • Dry-Bulb Temperature(tdry)

sgpsondeC1.00:
  • Raw data stream - documentation not supported(Raw data stream - documentation not supported)

sgplssondeC1.c1:
  • east longitude for all the input platforms.(lon)
  • altitude above sea levelaltunits(alt)
  • Time offset from base_time(base_time)
  • pressure at constant pressure surface(pres)
  • Relative humidity scaled, by total column amount from MWR(rh)
  • Dry-Bulb Temperature(tdry)
  • north latitude for all the input platforms.(lat)
  • Time offset of tweaks from base_time(time_offset)


Back To Table of Contents

DQRID : D030419.2
Start DateStart TimeEnd DateEnd Time
04/15/2003233204/16/20030124
Subject:
SGP/SONDE/C1 - Broken Temperature Sensor
DataStreams:sgpsondewnpnC1.a1, sgpsondewnpnC1.b1
Description:
The temperature sensor broke shortly after launch as a result all variables that are 
affected by temperature are incorrect.
Measurements:sgpsondewnpnC1.a1:
  • Dry-Bulb Temperature(tdry)
  • Relative humidity scaled, by total column amount from MWR(rh)
  • Surface dew point temperature(dp)

sgpsondewnpnC1.b1:
  • Surface dew point temperature(dp)
  • Dry-Bulb Temperature(tdry)
  • Relative humidity scaled, by total column amount from MWR(rh)


Back To Table of Contents

DQRID : D030427.1
Start DateStart TimeEnd DateEnd Time
04/18/2003113004/18/20031310
Subject:
SGP/SONDE/C1 - Broken temperature sensor
DataStreams:sgpsondewnpnC1.a1, sgpsondewnpnC1.b1
Description:
The temperature sensor on this radiosonde broke after launch.  All temperature-related 
variables (dp, tdry, rh) are incorrect.
Measurements:sgpsondewnpnC1.a1:
  • Dry-Bulb Temperature(tdry)
  • Relative humidity scaled, by total column amount from MWR(rh)
  • Surface dew point temperature(dp)

sgpsondewnpnC1.b1:
  • Surface dew point temperature(dp)
  • Dry-Bulb Temperature(tdry)
  • Relative humidity scaled, by total column amount from MWR(rh)


Back To Table of Contents

DQRID : D030507.3
Start DateStart TimeEnd DateEnd Time
05/04/2003113005/04/20031145
05/04/2003233005/05/20030116
Subject:
SGP/SONDE/C1 - Broken temperature sensors
DataStreams:sgpsondewnpnC1.a1, sgpsondewnpnC1.b1
Description:
The temperature sensors broke at launch on both of these soundings.  All of the 
temperature-related data (tdry, rh, dp) are incorrect.
Measurements:sgpsondewnpnC1.a1:
  • Dry-Bulb Temperature(tdry)
  • Relative humidity scaled, by total column amount from MWR(rh)
  • Surface dew point temperature(dp)

sgpsondewnpnC1.b1:
  • Surface dew point temperature(dp)
  • Dry-Bulb Temperature(tdry)
  • Relative humidity scaled, by total column amount from MWR(rh)


Back To Table of Contents

DQRID : D030614.1
Start DateStart TimeEnd DateEnd Time
06/09/2003173006/09/20031737
Subject:
SGP/SONDE/C1 - Broken temperature sensor
DataStreams:sgpsondewnpnC1.a1, sgpsondewnpnC1.b1
Description:
The temperature sensor broke at launch on this sounding.  All of the temperature-related 
data (tdry, rh, dp) are incorrect.
Measurements:sgpsondewnpnC1.a1:
  • Dry-Bulb Temperature(tdry)
  • Relative humidity scaled, by total column amount from MWR(rh)
  • Surface dew point temperature(dp)

sgpsondewnpnC1.b1:
  • Surface dew point temperature(dp)
  • Dry-Bulb Temperature(tdry)
  • Relative humidity scaled, by total column amount from MWR(rh)


Back To Table of Contents

DQRID : D030707.7
Start DateStart TimeEnd DateEnd Time
06/22/2003233106/22/20032331
Subject:
SGP/SONDE/C1 - Incorrect surface RH value.
DataStreams:sgpsondewnpnC1.a1, sgpsondewnpnC1.b1
Description:
The surface RH value, reported as 0%RH should be 52%.  This resulted from a typographical 
error by the operator when entering the surface data.
Measurements:sgpsondewnpnC1.a1:
  • Relative humidity scaled, by total column amount from MWR(rh)
  • Surface dew point temperature(dp)

sgpsondewnpnC1.b1:
  • Surface dew point temperature(dp)
  • Relative humidity scaled, by total column amount from MWR(rh)


Back To Table of Contents

DQRID : D030722.1
Start DateStart TimeEnd DateEnd Time
07/19/2003173007/19/20031930
Subject:
SGP/SONDE/C1 - Broken temperature sensor
DataStreams:sgpsondewnpnC1.a1, sgpsondewnpnC1.b1
Description:
The temperature sensor broke at launch on this sounding.  All of the temperature-related 
data (tdry, rh, dp) are incorrect.
Measurements:sgpsondewnpnC1.a1:
  • Dry-Bulb Temperature(tdry)
  • Relative humidity scaled, by total column amount from MWR(rh)
  • Surface dew point temperature(dp)

sgpsondewnpnC1.b1:
  • Surface dew point temperature(dp)
  • Dry-Bulb Temperature(tdry)
  • Relative humidity scaled, by total column amount from MWR(rh)


Back To Table of Contents

DQRID : D030807.1
Start DateStart TimeEnd DateEnd Time
08/02/2003172508/02/20031726
Subject:
SGP/SONDE/C1 - A few bad temperature values at the beginning of the sounding
DataStreams:sgpsondewnpnC1.a1, sgpsondewnpnC1.b1
Description:
I've never seen this before.  The temperature reported by the radiosonde dropped over 30 
degC just after launch (usually a symptom of a broken temperature sensor), but then 
recovered after 14 seconds of bad readings.  The temperatures from 2 seconds through 14 seconds 
after launch are incorrect, the remainder of the sounding looks fine.  I have sent the 
data files to Vaisala for their consideration.
Measurements:sgpsondewnpnC1.a1:
  • Dry-Bulb Temperature(tdry)
  • Surface dew point temperature(dp)

sgpsondewnpnC1.b1:
  • Surface dew point temperature(dp)
  • Dry-Bulb Temperature(tdry)


Back To Table of Contents

DQRID : D031112.1
Start DateStart TimeEnd DateEnd Time
11/01/2003113311/01/20031315
Subject:
SGP/SONDE/C1 - Broken temperature sensor
DataStreams:sgpsondewnpnC1.b1
Description:
The temperature sensor broke at launch on this sounding.  All of the temperature-related 
data (tdry, rh, dp) are incorrect.
Measurements:sgpsondewnpnC1.b1:
  • Surface dew point temperature(dp)
  • Dry-Bulb Temperature(tdry)
  • Relative humidity scaled, by total column amount from MWR(rh)


Back To Table of Contents

DQRID : D040127.2
Start DateStart TimeEnd DateEnd Time
01/16/2004201501/16/20042151
Subject:
SGP/SONDE/C1 - Bad RH Data
DataStreams:sgpsondewnpnC1.b1
Description:
The RH values during the first half of this sounding oscillate between reasonable values 
and near-zero values.  The oscillation is irregular and seems to be related to failure of 
the RH sensor heating process.
Measurements:sgpsondewnpnC1.b1:
  • Surface dew point temperature(dp)
  • Relative humidity scaled, by total column amount from MWR(rh)


Back To Table of Contents

DQRID : D040219.1
Start DateStart TimeEnd DateEnd Time
02/09/2004053002/09/20040601
Subject:
SGP/SONDE/C1 - Bad RH Data
DataStreams:sgpsondewnpnC1.b1
Description:
The RH values during the first part of this sounding oscillate between reasonable values 
and near-zero values.  The oscillation seems to be related to failure of the RH sensor 
heating process.
Measurements:sgpsondewnpnC1.b1:
  • Surface dew point temperature(dp)
  • Relative humidity scaled, by total column amount from MWR(rh)


Back To Table of Contents

DQRID : D040219.2
Start DateStart TimeEnd DateEnd Time
02/02/2004053002/02/20040826
Subject:
SGP/SONDE/C1 - Surface pressure incorrect
DataStreams:sgpsondewnpnC1.b1
Description:
I think the operator inadvdertently transposed to digits when entering the surface 
pressure value.  The value entered is 987.0 hPa but the value shown in the raw data file at 
launch is 978.0.  As a result, the absolute altitudes in this sounding will be slightly 
incorrect as will be the ascent rate during the first 30 seconds of flight.
Measurements:sgpsondewnpnC1.b1:
  • Ascent Rate(asc)
  • altitude above sea levelaltunits(alt)


Back To Table of Contents

DQRID : D040223.1
Start DateStart TimeEnd DateEnd Time
02/19/2004174602/19/20041946
Subject:
SGP/SONDE/C1 - Broken temperature sensor
DataStreams:sgpsondewnpnC1.b1
Description:
The temperature sensor broke at launch on this sounding.  All of the temperature-related 
data (tdry, rh, dp) are incorrect.
Measurements:sgpsondewnpnC1.b1:
  • Surface dew point temperature(dp)
  • Dry-Bulb Temperature(tdry)
  • Relative humidity scaled, by total column amount from MWR(rh)


Back To Table of Contents

DQRID : D040301.1
Start DateStart TimeEnd DateEnd Time
02/27/2004053102/27/20040721
Subject:
SGP/SONDE/C1 - Broken temperature sensor
DataStreams:sgpsondewnpnC1.b1
Description:
The temperature sensor broke shortly after launch on this sounding.  All of the 
temperature-related data (tdry, rh, dp) are incorrect.
Measurements:sgpsondewnpnC1.b1:
  • Surface dew point temperature(dp)
  • Dry-Bulb Temperature(tdry)
  • Relative humidity scaled, by total column amount from MWR(rh)


Back To Table of Contents

DQRID : D040415.2
Start DateStart TimeEnd DateEnd Time
04/13/2004122904/13/20041301
Subject:
SGP/SONDE/C1 - Temperature sensor broke high into the sounding
DataStreams:sgpsondewnpnC1.b1
Description:
The temperature sensor on this radiosonde appeared to break 56 minutes and 22 seconds into 
the sounding at an altitude of 16570 m.  All the data below this point are good; only 
the data above this point to the end of the sounding (88 minutes and 14 seconds) are bad.
Measurements:sgpsondewnpnC1.b1:
  • Surface dew point temperature(dp)
  • Dry-Bulb Temperature(tdry)
  • Relative humidity scaled, by total column amount from MWR(rh)


Back To Table of Contents

DQRID : D041005.1
Start DateStart TimeEnd DateEnd Time
10/02/2004113010/02/20041131
Subject:
SGP/SONDE/C1 - Incorrect surface temperature
DataStreams:sgpsondewnpnC1.b1
Description:
The operator entered a the surface temperature incorrectly on this sounding.  The sonde 
data file shows the temperature as 33.5 degC but the operations log shows it as 3.5 degC.  
The first temperature recorded by the sonde after launch is 3.7 degC, consistent with the 
typical early morning inversion.
Measurements:sgpsondewnpnC1.b1:
  • Surface dew point temperature(dp)
  • Dry-Bulb Temperature(tdry)
  • Relative humidity scaled, by total column amount from MWR(rh)


Back To Table of Contents

DQRID : D041013.4
Start DateStart TimeEnd DateEnd Time
01/16/2004233001/17/20041830
01/18/2004053001/18/20040630
01/21/2004053001/21/20040630
Subject:
SGP/SONDE/C1 - Scheduled Soundings Missed
DataStreams:sgpsondeC1.00, sgpsondewnpnC1.b1
Description:
The following scheduled sonde launches were missed due to computer 
system failures:

20040116.2330
20040117.0530
20040117.1130
20040117.1730
20040118.0530
20040121.0530
Measurements:sgpsondewnpnC1.b1:
  • Surface dew point temperature(dp)
  • Time offset from base_time(base_time)
  • surface wind speed(wspd)
  • model zonal wind velocity(u_wind)
  • Relative humidity scaled, by total column amount from MWR(rh)
  • north latitude for all the input platforms.(lat)
  • Ascent Rate(asc)
  • pressure at constant pressure surface(pres)
  • Wind Direction(deg)
  • Wind Status(wstat)
  • east longitude for all the input platforms.(lon)
  • Dry-Bulb Temperature(tdry)
  • Time offset of tweaks from base_time(time_offset)
  • model meridional wind velocity(v_wind)
  • altitude above sea levelaltunits(alt)

sgpsondeC1.00:
  • Raw data stream - documentation not supported(Raw data stream - documentation not supported)


Back To Table of Contents

DQRID : D050201.1
Start DateStart TimeEnd DateEnd Time
01/19/2005053101/19/20050706
Subject:
SGP/SONDE/C1 - Possibly bad pressure sensor or operator data entry error
DataStreams:sgpsondewnpnC1.b1
Description:
There is a discrepency between the surface pressure and temperature data entered by the 
operator and that recorded by the THWAPS.  Review of the raw data from the radiosonde shows 
that the pressure was periodically varying by as much as 12 hPa (~988 to 1000)in the 
time period before launch.  The operator entry of 998.2 is at the high end of this range - 
the concurrent THWAPS reading was about 988.4 at the low end.  The operator entered 
temperature 6.2 degC is considerably higher than the THWAPS value of 1.8.  The pre-flight log 
entry for this sounding is missing from the OMIS database.  If not for the extremely 
unstable pressure reading I would have assumed this was an operator error.  It will take some 
more research to figure out what is going on.
Measurements:sgpsondewnpnC1.b1:
  • Surface dew point temperature(dp)
  • Time offset from base_time(base_time)
  • surface wind speed(wspd)
  • model zonal wind velocity(u_wind)
  • Relative humidity scaled, by total column amount from MWR(rh)
  • north latitude for all the input platforms.(lat)
  • Ascent Rate(asc)
  • pressure at constant pressure surface(pres)
  • Wind Direction(deg)
  • Wind Status(wstat)
  • east longitude for all the input platforms.(lon)
  • Dry-Bulb Temperature(tdry)
  • Time offset of tweaks from base_time(time_offset)
  • model meridional wind velocity(v_wind)
  • altitude above sea levelaltunits(alt)


Back To Table of Contents

DQRID : D050421.5
Start DateStart TimeEnd DateEnd Time
04/11/2005174904/11/20051920
Subject:
SGP/SONDE/C1 - Surface pressure incorrect
DataStreams:sgpsondewnpnC1.b1
Description:
I think the operator inadvdertently entered an incorrect surface pressure value.  The 
value entered is 988.8 hPa but the value shown in the raw data file at launch is 968.8.  As a 
result, the absolute altitudes in this sounding will be slightly incorrect as will be 
the ascent rate during the first 30 seconds of flight.
Measurements:sgpsondewnpnC1.b1:
  • Ascent Rate(asc)
  • altitude above sea levelaltunits(alt)


Back To Table of Contents

DQRID : D050510.1
Start DateStart TimeEnd DateEnd Time
04/26/2005172604/26/20051910
Subject:
SGP/SONDE/C1 - Surface pressure bad and other data noisy
DataStreams:sgpsondewnpnC1.b1
Description:
I was checking this sounding because the surface pressure entered by the operator was 
considerably higher than that recorded by the TWHAPS and SMOS.  I'm not sure why, but the 
pressure data are very noisy while the sonde is on the ground (which accounts for the 
incorrect surface pressure) and the RH data aloft do not look terrible but do not look great 
either.
Measurements:sgpsondewnpnC1.b1:
  • Surface dew point temperature(dp)
  • Time offset from base_time(base_time)
  • surface wind speed(wspd)
  • model zonal wind velocity(u_wind)
  • Relative humidity scaled, by total column amount from MWR(rh)
  • north latitude for all the input platforms.(lat)
  • Ascent Rate(asc)
  • pressure at constant pressure surface(pres)
  • Wind Direction(deg)
  • Wind Status(wstat)
  • east longitude for all the input platforms.(lon)
  • Dry-Bulb Temperature(tdry)
  • Time offset of tweaks from base_time(time_offset)
  • model meridional wind velocity(v_wind)
  • altitude above sea levelaltunits(alt)


Back To Table of Contents

DQRID : D050510.2
Start DateStart TimeEnd DateEnd Time
04/29/2005232904/30/20050111
Subject:
SGP/SONDE/C1 - Surface pressure incorrect
DataStreams:sgpsondewnpnC1.b1
Description:
I think the operator inadvdertently typed an 89 instead of a 78 when entering the surface 
pressure value.  The value entered is 989.9 hPa but the value shown in the raw data file 
at launch is 978.9.  As a result, the absolute altitudes in this sounding will be 
slightly incorrect as will be the ascent rate during the first 30 seconds of flight.
Measurements:sgpsondewnpnC1.b1:
  • Ascent Rate(asc)
  • altitude above sea levelaltunits(alt)


Back To Table of Contents

DQRID : D050603.4
Start DateStart TimeEnd DateEnd Time
05/11/2005053005/11/20050750
Subject:
SGP/SONDE/C1 - Surface pressure incorrect
DataStreams:sgpsondewnpnC1.b1
Description:
I think the operator inadvdertently mistyped a digit when entering the surface pressure 
value.  The value entered is 975.6 hPa but the value shown in the raw data file at launch 
is 972.6.  As a result, the absolute altitudes in this sounding will be slightly incorrect 
as will be the ascent rate during the first 30 seconds of flight.
Measurements:sgpsondewnpnC1.b1:
  • Ascent Rate(asc)
  • altitude above sea levelaltunits(alt)


Back To Table of Contents

DQRID : D050725.1
Start DateStart TimeEnd DateEnd Time
07/17/2005234707/18/20050141
Subject:
SGP/SONDE/C1 - Bad RH Data
DataStreams:sgpsondewnpnC1.b1
Description:
The RH values below 6 km are incorrect.  The problem relates to a failure of the GC25 
ground check set used before this particular sounding.  The failure seems to have affected 
the sensor calibration with the effect that one of the two sensors was reading artificially 
high.  Because the internal processing software uses the highest of the two sensor 
readings, the bad sensor value is chosen whenever it is not heated.
Measurements:sgpsondewnpnC1.b1:
  • Surface dew point temperature(dp)
  • Relative humidity scaled, by total column amount from MWR(rh)


Back To Table of Contents

DQRID : D050811.5
Start DateStart TimeEnd DateEnd Time
08/01/2005113208/01/20050116
Subject:
SGP/SONDE/C1 - Bad T/RH and surface P.
DataStreams:sgpsondewnpnC1.b1
Description:
Apparently multiple failures.  The radiosonde temperature sensor broke on launch causing 
an approximate 35 degC negative offset and as a result, the RH is incorrect.  Furthermore, 
it appears that the pressure sensor was off by approximately 4 hPa, though this would 
not affect the altitude calculation, the absolute pressure is wrong.
Measurements:sgpsondewnpnC1.b1:
  • Dry-Bulb Temperature(tdry)
  • Relative humidity scaled, by total column amount from MWR(rh)
  • pressure at constant pressure surface(pres)


Back To Table of Contents

DQRID : D050912.2
Start DateStart TimeEnd DateEnd Time
09/09/2005113209/09/20051332
Subject:
SGP/SONDE/C1 - Temperature/RH incorrect
DataStreams:sgplssondeC1.c1, sgpsondewnpnC1.b1
Description:
The temperature throughout this sounding is too high and as a result the RH values will be 
incorrect as well.  I'm not sure what is wrong here but the operators noted reasonable 
values (18.1 degC, 87%) in the log before launch.  Review of the raw data, however, shows 
the sonde reporting temperatures nearly 20 degC higher.  I suppose it is possible that 
the operator entered into the log the reference temperature from the GC25 ground check set 
rather than the temperature reported by the sonde - I can't think of any other 
explanation - there is no doubt that the temperature sensor on this sonde was bad.
Measurements:sgpsondewnpnC1.b1:
  • Surface dew point temperature(dp)
  • Dry-Bulb Temperature(tdry)
  • Relative humidity scaled, by total column amount from MWR(rh)

sgplssondeC1.c1:
  • Relative humidity scaled, by total column amount from MWR(rh)
  • Dry-Bulb Temperature(tdry)


Back To Table of Contents

DQRID : D051027.1
Start DateStart TimeEnd DateEnd Time
10/24/2005114010/24/20051204
Subject:
SGP/SONDE/C1 - Bad RH Data
DataStreams:sgpsondewnpnC1.b1
Description:
The RH values during this sounding oscillate between reasonable values and near-zero 
values.  The oscillation is due to failure of the RH sensor heating process.
Measurements:sgpsondewnpnC1.b1:
  • Surface dew point temperature(dp)
  • Relative humidity scaled, by total column amount from MWR(rh)


Back To Table of Contents

DQRID : D051121.1
Start DateStart TimeEnd DateEnd Time
04/13/2005234604/15/20051732
Subject:
SGP/SONDE/C1 - Sonde RH values incorrect
DataStreams:sgpsondewnpnC1.b1
Description:
RH values for all sondes launched during this time were incorrect due to a faulty Ground 
Check set which damaged or conditioned the RH sensor improperly.
Measurements:sgpsondewnpnC1.b1:
  • Surface dew point temperature(dp)
  • Relative humidity scaled, by total column amount from MWR(rh)


Back To Table of Contents

DQRID : D060303.1
Start DateStart TimeEnd DateEnd Time
01/17/2004233101/18/20040108
01/18/2004113801/18/20041252
01/18/2004172901/18/20041852
01/18/2004233901/19/20040111
01/19/2004053101/19/20040711
01/19/2004113601/19/20041316
01/19/2004172301/19/20041752
01/19/2004233101/20/20040101
01/20/2004053101/20/20040703
01/20/2004113201/20/20041332
01/20/2004172801/20/20041928
01/20/2004233001/21/20040130
01/21/2004173101/21/20041931
Subject:
SGP/SONDE/C1 - DigiCORAIII failed, replaced with S01/S02 launches
DataStreams:sgpsondeC1.00, sgpsondewnpnC1.b1
Description:
The digiCORA-III failed on Saturday 2004-01-17.  The operators reported that they were 
unable to load the software and conduct normal soundings.	Following procedure, they 
conducted the regular soundings by using the S01/S02 systems as allowed by the AIRS IOP schedule.
The netCDF header fields "input_source" and "facility_id" will mention which of the 
S01/S02 systems was used in these launches.
Measurements:sgpsondewnpnC1.b1:
  • east longitude for all the input platforms.(lon)
  • north latitude for all the input platforms.(lat)
  • altitude above sea levelaltunits(alt)

sgpsondeC1.00:
  • Raw data stream - documentation not supported(Raw data stream - documentation not supported)


Back To Table of Contents



END OF DATA