DQR ID | Subject | Data Streams Affected |
---|---|---|
D040408.1 | SGP/ECOR/E16 - Data suspect due to inability to run QC | sgpecorE16.00, sgp30ecorE16.b1 |
D041103.2 | SGP/ECOR/E16 - No water vapor density and CO2 concentration data due to sensor failure. | sgpecorE16.00, sgp30ecorE16.b1 |
D041223.2 | SGP/ECOR/E16 - No data due to hardware problem | sgpecorE16.00, sgp30ecorE16.b1 |
D050421.2 | SGP/ECOR/E16 - Reprocess: Incorrectly flagged (marked as "bad") H2O/CO2 data | sgp30ecorE16.b1 |
D051031.4 | SGP/ECOR/E16 - Data Missing | sgp30ecorE16.b1 |
D060104.1 | SGP/ECOR/E16 - Sonic serial communication errors caused incorrect fluxes | sgp30ecorE16.b1 |
D060505.3 | SGP/ECOR/E16 - Data Missing | sgp30ecorE16.b1 |
D060619.4 | SGP/ECOR/E16 - LI-7500 Pressure and Temperature missing | sgp30ecorE16.b1 |
D060707.4 | SGP/ECOR/E16 - Latent Heat and CO2 Fluxes Incorrect | sgp30ecorE16.b1 |
D060816.2 | SGP/ECOR/E16 - Missing Data | sgp30ecorE16.b1 |
Start Date | Start Time | End Date | End Time |
---|---|---|---|
01/12/2004 | 0000 | 04/28/2004 | 1500 |
Subject: | SGP/ECOR/E16 - Data suspect due to inability to run QC |
DataStreams: | sgpecorE16.00, sgp30ecorE16.b1 |
Description: | Some QC checks were unsuccessful due to a communication failure that resulted in contaminated QC field data. All the data that are based on water vapor density and CO2 concentration are "suspect" because many of the standard QC checks were not employed. |
Measurements: | sgp30ecorE16.b1:
sgpecorE16.00:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
11/02/2004 | 0130 | 11/09/2004 | 1530 |
Subject: | SGP/ECOR/E16 - No water vapor density and CO2 concentration data due to sensor failure. |
DataStreams: | sgpecorE16.00, sgp30ecorE16.b1 |
Description: | The infrared gas analyzer (IRGA) failed on Nov. 2, 2004, 02:00; the system continued to operate without H2O and CO2 data until Nov. 9, 2004, 15:30; then it stopped due to another hardware failure. The system was returned in service on Nov. 12, 2004, 18:00. The latent heat flux and CO2 flux data are irrevocably lost for the period from Nov. 2, 2004, 02:00 to Nov. 12, 2004, 18:00. |
Measurements: | sgp30ecorE16.b1:
sgpecorE16.00:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
11/09/2004 | 1530 | 11/12/2004 | 1800 |
Subject: | SGP/ECOR/E16 - No data due to hardware problem |
DataStreams: | sgpecorE16.00, sgp30ecorE16.b1 |
Description: | The system did not work due to hardware problems from Nov. 9, 2004, 15:30 to Nov. 12, 2004, 18:00; all the data is irrevocably lost. |
Measurements: | sgp30ecorE16.b1:
sgpecorE16.00:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
02/23/2004 | 0000 | 03/13/2005 | 0030 |
Subject: | SGP/ECOR/E16 - Reprocess: Incorrectly flagged (marked as "bad") H2O/CO2 data |
DataStreams: | sgp30ecorE16.b1 |
Description: | Due to system clock instability on ECOR computers their system time is adjusted approximately once per hour; sometimes this adjustment leads to backward time jumps over midnight, into the previous day. In this case all the data based on CO2/H2O measurements might be erroneously marked as bad. Below is a list of times when that might have happen. SITE YEAR MONTH DAY HOUR MINUTE 16 2004 02 23 00 00 16 2004 02 28 00 00 16 2004 03 01 00 00 16 2004 03 09 00 00 16 2004 03 15 00 00 16 2004 03 17 00 00 16 2004 03 22 00 00 16 2004 03 30 00 00 16 2004 04 02 00 00 16 2004 07 22 00 00 16 2004 08 06 00 00 16 2004 09 05 00 00 16 2004 09 20 00 00 16 2005 03 13 00 00 |
Measurements: | sgp30ecorE16.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
07/14/2005 | 1500 | 07/18/2005 | 1300 |
Subject: | SGP/ECOR/E16 - Data Missing |
DataStreams: | sgp30ecorE16.b1 |
Description: | The data was missing during the stated period. |
Measurements: | sgp30ecorE16.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
11/09/2005 | 1630 | 01/18/2006 | 1230 |
Subject: | SGP/ECOR/E16 - Sonic serial communication errors caused incorrect fluxes |
DataStreams: | sgp30ecorE16.b1 |
Description: | Communication problem on the serial connection to the SONIC caused data dropouts and subsequent data corruption. In entering the ECOR Linux box through the sonic serial port, the serial port or the Linux driver handling it (likely the latter) sometimes drops entire fields (one or more) within a line of raw sonic data. When that happens, the ECOR programming can not properly parse the data (if it's not there to parse) and so the flux and mean measurements come out as garbage in the 30 minute ECOR data that is collected for ingest. |
Measurements: | sgp30ecorE16.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
04/28/2006 | 1530 | 05/24/2006 | 1500 |
Subject: | SGP/ECOR/E16 - Data Missing |
DataStreams: | sgp30ecorE16.b1 |
Description: | Data is missing because of the failure of the LINUX box data acquisition system. |
Measurements: | sgp30ecorE16.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
06/17/2006 | 0230 | 08/02/2006 | 1530 |
Subject: | SGP/ECOR/E16 - LI-7500 Pressure and Temperature missing |
DataStreams: | sgp30ecorE16.b1 |
Description: | The pressure and temperature measurements were not recorded; the LI-7500 serial datastream was not being captured by the ECOR system because of a serial port failure. Some degradation of the latent and sensible heat fluxes may have occurred during high summer temperatures. The error in the fluxes would be no more than 5 to 10% of the measurement, still well within the measurement error of the system. |
Measurements: | sgp30ecorE16.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
06/21/2006 | 1500 | 06/23/2006 | 1600 |
Subject: | SGP/ECOR/E16 - Latent Heat and CO2 Fluxes Incorrect |
DataStreams: | sgp30ecorE16.b1 |
Description: | The LI-7500 CO2/H2O water vapor sensor was removed during this period. |
Measurements: | sgp30ecorE16.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
07/14/2006 | 0630 | 07/19/2006 | 2000 |
Subject: | SGP/ECOR/E16 - Missing Data |
DataStreams: | sgp30ecorE16.b1 |
Description: | The ECOR data was missing during the stated period. |
Measurements: | sgp30ecorE16.b1:
|