Data Quality Reports for Session: 103571 User: okkonen Completed: 01/08/2007


TABLE OF CONTENTS

DQR IDSubjectData Streams Affected
D040728.1NSA/METTWR/C1 - CMH Dew Point and RH data Incorrectnsamettwr4hC1.b1
D040930.1NSA/METTWR/C1 - Instrument problem, Contamination, False signalnsamettwr4hC1.b1
D041011.2NSA/METTWR/C1 - 20m Temperature/RH Sensor Failingnsamettwr4hC1.b1
D050527.2NSA/METTWR/C1 - Incorrect Maximum for Precip Valuesnsamettwr4hC1.b1
D051025.2NSA/METTWR/C1 - Data 1-minute behindnsamettwr4hC1.b1
D051101.4NSA/METTWR/C1 - Reprocess: Wind direction data incorrectnsamettwr4hC1.b1
D060817.4NSA/METTWR/C1 - Reprocess: Barometric Data Changed from hPa to kPansamettwr4hC1.b1


DQRID : D040728.1
Start DateStart TimeEnd DateEnd Time
07/21/2004150008/03/20042300
Subject:
NSA/METTWR/C1 - CMH Dew Point and RH data Incorrect
DataStreams:nsamettwr4hC1.b1
Description:
The Chilled Mirror Dew Point reported negative dew point values.  This caused the RH to be 
much lower than reality also.  Compared to the 2m level the RH and dew point from the 
CMH are incorrect.  Mirror was dirty, it was removed, cleaned and recalibrated.
Measurements:nsamettwr4hC1.b1:
  • Chilled Mirror Calculated Relative Humidity(CMHRH)
  • Chilled Mirror Dew Point(CMHDP)


Back To Table of Contents

DQRID : D040930.1
Start DateStart TimeEnd DateEnd Time
09/27/2004152109/29/20040452
Subject:
NSA/METTWR/C1 - Instrument problem, Contamination, False signal
DataStreams:nsamettwr4hC1.b1
Description:
Heavy, wet and blowing snow and ice caused measurement problems with the sonic anemometer 
mounted at the 2m level.  Erroneous readings caused both the wind speed and direction 
values to be reported anomolously.  Once the heavy, wet snow and ice stopped the readings 
returned to normal.
Measurements:nsamettwr4hC1.b1:
  • Sonic Arithmetic Mean Wind Speed(SonicWS_S_WVT)
  • Sonic Vector Averaged Wind Direction(SonicWD_DU_WVT)
  • Average Y Component of Sonic Wind Speed(SonicY_AVG)
  • Standard Deviation of Sonic Vector Averaged Wind Direction(SonicWD_SDU_WVT)
  • Average Sonic Static Speed of Sound(SonicS_AVG)
  • Sonic Vector Averaged Wind Speed(SonicWS_U_WVT)
  • Average X Component of Sonic Wind Speed(SonicX_AVG)


Back To Table of Contents

DQRID : D041011.2
Start DateStart TimeEnd DateEnd Time
07/19/2004150009/08/20042321
Subject:
NSA/METTWR/C1 - 20m Temperature/RH Sensor Failing
DataStreams:nsamettwr4hC1.b1
Description:
The 20m temperature and RH sensor began reading high on 20040719.
Aspirator fan failure caused a portion of the high reading.  New fan
failed to correct for all errors.  Sensor replaced on 20040908 with
recently calibrated sensor.
Measurements:nsamettwr4hC1.b1:
  • Standard Deviation of 20m Calculated Dew Point(DP20M_STD)
  • Standard Deviation of 20m Calculated Vapor Pressure(VP20M_STD)
  • 20m Average Temperature(T20M_AVG)
  • Standard Deviation of 20m Relative Humidity(RH20M_STD)
  • 20m Average Relative Humidity(RH20M_AVG)
  • 20m Average Calculated Vapor Pressure(VP20M_AVG)
  • 20m Average Calculated Dew Point(DP20M_AVG)
  • Standard Deviation of 20m Temperature(T20M_STD)


Back To Table of Contents

DQRID : D050527.2
Start DateStart TimeEnd DateEnd Time
10/31/2003000005/26/20051014
Subject:
NSA/METTWR/C1 - Incorrect Maximum for Precip Values
DataStreams:nsamettwr4hC1.b1
Description:
The max values for cumulative rain sum of 99 mm and the rain rate of 999 mm/hr are 
incorrect.  In communication with the manufacturer it has been found that the manual was in 
error.  The actual max values of the cumulative rain sum is 99.99 mm and the rain rate is 
999.99 mm/hr.
Measurements:nsamettwr4hC1.b1:
  • Precipitation Rate(PcpRate)
  • Cumulative Water Sum(CumH2O)


Back To Table of Contents

DQRID : D051025.2
Start DateStart TimeEnd DateEnd Time
10/31/2003000009/14/20051420
Subject:
NSA/METTWR/C1 - Data 1-minute behind
DataStreams:nsamettwr4hC1.b1
Description:
Data from the Barometer, Chilled Mirror Hygrometer and the Present Weather Sensor were 
one-minute behind due to timing problems collecting data from the Serial Data Multiplexer 
that handled these sensors.
Measurements:nsamettwr4hC1.b1:
  • 15 minute Present Weather Code(PwCod15mi)
  • 1 minute Average Visibility(AvgVis1mi)
  • Chilled Mirror Dew Point(CMHDP)
  • Instant Present Weather Code(InstPwCod)
  • Chilled Mirror Calculated Saturation Vapor Pressure(SatVPCMH)
  • Chilled Mirror Calculated Relative Humidity(CMHRH)
  • Chilled Mirror Calculated Vapor Pressure(VPCMH)
  • 1 hour Present Weather Code(PwCod1hr)
  • Cumulative Snow Sum(CumSnow)
  • 10 minute Average Visibility(AvgVis10m)
  • Chilled Mirror Temperature(CMHTemp)
  • Precipitation Rate(PcpRate)
  • Cumulative Water Sum(CumH2O)
  • Present Weather Sensor Alarm(PWSAlarm)
  • Atmospheric Pressure(AtmPress)


Back To Table of Contents

DQRID : D051101.4
Start DateStart TimeEnd DateEnd Time
10/31/2003000010/20/20051900
Subject:
NSA/METTWR/C1 - Reprocess: Wind direction data incorrect
DataStreams:nsamettwr4hC1.b1
Description:
Wind direction data is off by 30 degrees for all wind sensors.  The 40-m tower was 
misaligned to true north.
Measurements:nsamettwr4hC1.b1:
  • 40m Vector Averaged Wind Direction(WD40M_DU_WVT)
  • 2m Vector Averaged Wind Direction(WD2M_DU_WVT)
  • 20m Vector Averaged Wind Direction(WD20M_DU_WVT)
  • Sonic Vector Averaged Wind Direction(SonicWD_DU_WVT)
  • 10m Vector Averaged Wind Direction(WD10M_DU_WVT)


Back To Table of Contents

DQRID : D060817.4
Start DateStart TimeEnd DateEnd Time
10/31/2003000007/12/20061608
Subject:
NSA/METTWR/C1 - Reprocess: Barometric Data Changed from hPa to kPa
DataStreams:nsamettwr4hC1.b1
Description:
Barometric pressure data was converted from hPa to kPa in order to standardize the 
measurement units among ARM sites and to conform to accepted standard units determined by the 
scientific community.
Measurements:nsamettwr4hC1.b1:
  • Atmospheric Pressure(AtmPress)


Back To Table of Contents