Data Quality Reports for Session: 103590 User: gnk Completed: 01/09/2007


TABLE OF CONTENTS

DQR IDSubjectData Streams Affected
D051104.3SGP/EBBR/E13 - Loose connectionssgp5ebbrE13.b1, sgp15ebbrE13.b1, sgp30ebbrE13.b1


DQRID : D051104.3
Start DateStart TimeEnd DateEnd Time
08/17/2005223010/05/20051600
Subject:
SGP/EBBR/E13 - Loose connections
DataStreams:sgp5ebbrE13.b1, sgp15ebbrE13.b1, sgp30ebbrE13.b1
Description:
The tair_bot spiked around midday, as if it is temperature related, and may have indicated 
a loose connection.

The sensible and latyent heat fluxes and Bowen ratio were incorrect when this condition 
occurred.
Measurements:sgp15ebbrE13.b1:
  • Left air temperature(tair_l)
  • Right air temperature(tair_r)

sgp5ebbrE13.b1:
  • bottom air temperature(tair_bot)

sgp30ebbrE13.b1:
  • bottom air temperature(tair_bot)
  • ratio of sensible/latent heat fluxes (Bowen ratio)(bowen)
  • latent heat flux(e)
  • corrected sensible heat flux(h)


Back To Table of Contents



END OF DATA