DQR ID | Subject | Data Streams Affected |
---|---|---|
D000608.18 | TWP/C2/Sonde Missing Data | twpsondeC2.00, twpsondewnpnC2.00, twpsondewnpnC2.a0, twpsondewnpnC2.a1 |
D000615.10 | TWP/SONDE/C2 - Missing Winds | twpsondewnpnC2.a0, twpsondewnpnC2.a1 |
D000615.6 | TWP/C2/Balloon Soundings: Missing Flights | twpsondewnpnC2.a0, twpsondewnpnC2.a1 |
D000622.3 | TWP/C1 - Incorrect elevation reported in Manus Data | twpsondewnpnC1.a1 |
D000718.13 | TWP/C1/Balloon Soundings Maximum Altitude | twpsondewnpnC1.a0, twpsondewnpnC1.a1 |
D000718.14 | TWP/C1/Balloon Soundings Maximum Altitude | twpsondewnpnC1.a0, twpsondewnpnC1.a1 |
D000718.15 | TWP/C1/Balloon Soundings Maximum Altitude | twpsondewnpnC1.a0, twpsondewnpnC1.a1 |
D000718.16 | TWP/C1/Balloon Soundings Maximum Altitude | twpsondewnpnC1.a0, twpsondewnpnC1.a1 |
D000718.18 | TWP/C1/Balloon Soundings Maximum Altitude | twpsondewnpnC1.a0, twpsondewnpnC1.a1 |
D000719.1 | TWP/C1 - Generator Problem | twpmplC1.a1, twpwsiC1.00, twpmfrsrC1.a0, twpmfrsrC1.a1, twpmfrsrC1.b1, twpmwrlosC1.a1, twpmwrlosC1.b1, twpmwrtipC1.a1, twpmwrtipC1.b1, twpvceil25kC1.a1, twpvceil25kC1.b1, twpsondewnpnC1.a0, twpsondewnpnC1.a1 |
D001218.1 | SGP/SONDE/B1 - Incorrect surface temperature | sgpsondewnpnB1.00, sgpsondewnpnB1.a0, sgpsondewnpnB1.a1 |
D001221.3 | SGP/SONDE/B1 - Bad sounding data (incorrect calibration?) | sgpsondewnpnB1.00, sgpsondewnpnB1.a0, sgpsondewnpnB1.a1 |
D020613.10 | TWP/C2 Installation | twpsondewnpnC2.00, twpsondewnpnC2.a0, twpsondewnpnC2.a1 |
D020620.66 | TWP/C1 - Incorrect elevation reported in Manus Data | twpsondewnpnC1.a1 |
D021110.2 | SGP/SONDE/B4 - Soundings contaminated by interference | sgplssondeB4.c1, sgpqmemwrcolB4.c1, sgpsondewnpnB4.a1, sgpsondewnpnB4.b1 |
D021112.2 | SGP/SONDE/B4 - Possible interference in B4 sounding 20021110.1729 | sgpsondeB4.00, sgpsondewnpnB4.a1, sgpsondewnpnB4.b1 |
D021117.2 | SGP/SONDE/B4 - B4 sounding contaminated by interference | sgpsondeB4.00, sgpsondewnpnB4.a1, sgpsondewnpnB4.b1 |
D021121.2 | SGP/SONDE/B1 - Temperature sensor failed | sgpsondewnpnB1.a1, sgpsondewnpnB1.b1 |
D021206.1 | TWP/SONDE/C2 - Broken Temperature Sensor | twpsondewnpnC2.a1, twpsondewnpnC2.b1 |
D021229.1 | TWP/SONDE/C1 - Broken Temperature Sensor | twpsondewnpnC1.a1, twpsondewnpnC1.b1 |
D021231.2 | TWP/Sonde/C1 - Bad RH Values | twpsondewnpnC1.a1, twpsondewnpnC1.b1 |
D030419.1 | TWP/SONDE/C2 - Bad RH Data (AIRS Validation Sonde) | twpsondewnpnC2.a1, twpsondewnpnC2.b1 |
D030427.2 | TWP/SONDE/C1 - Questionable RH | twpsondewnpnC1.a1, twpsondewnpnC1.b1 |
D030503.1 | TWP/SONDE/C1 - Bad RH | twpsondewnpnC1.a1, twpsondewnpnC1.b1 |
D030517.2 | NSA/SONDE/C1 - Broken temperature sensor | nsasondewnpnC1.a1, nsasondewnpnC1.b1 |
D030603.3 | TWP/SONDE/C1 - Broken temperature sensor | twpsondewnpnC1.a1, twpsondewnpnC1.b1 |
D030608.4 | TWP/SONDE/C2 - Failure of RH sensor | twpsondewnpnC2.a1, twpsondewnpnC2.b1 |
D031008.1 | TWP/SONDE/C2 - Strange problem with data - | twpsondeC2.00, twpsondewnpnC2.00, twpsondewnpnC2.b1 |
D031231.1 | TWP/SONDE/C2 - RH sensor bad | twpsondewnpnC2.b1 |
D040127.3 | TWP/SONDE/C2 - Broken temperature sensors | twpsondewnpnC2.b1 |
D040208.2 | TWP/SONDE/C2 - Questionable rH data | twpsondewnpnC2.b1 |
D040219.4 | TWP/SONDE/C2 - Bad RH sensor | twpsondewnpnC2.b1 |
D040228.1 | TWP/SONDE/C1 - Broken temperature sensor | twpsondewnpnC1.b1 |
D040228.3 | TWP/SONDE/C1 - Bad RH sensors | twpsondewnpnC1.b1 |
D040425.1 | TWP/SONDE/C2 - Bad RH values aloft | twpsondewnpnC2.b1 |
D040530.1 | TWP/SONDE/C1 - Bad RH sensor | twpsondewnpnC1.a1, twpsondewnpnC1.b1 |
D040606.1 | TWP/SONDE/C1 - Bad RH at beginning of sounding | twpsondewnpnC1.b1 |
D040627.1 | TWP/SONDE/C1 - Bad RH at beginning of sounding | twpsondewnpnC1.b1 |
D040627.2 | TWP/SONDE/C1 - Bad RH in short interval aloft | twpsondewnpnC1.b1 |
D040711.1 | TWP/SONDE/C1 - Bad RH at beginning of sounding | twpsondewnpnC1.b1 |
D040711.2 | TWP/SONDE/C2 - RH sensor failure near surface | twpsondewnpnC2.b1 |
D040815.1 | TWP/SONDE/C2 - Operator used wrong calibration tape | twpsondewnpnC2.b1 |
D040822.1 | NSA/SONDE/C1 - This is a test sounding done using an RS80H radiosonde | nsasondewnpnC1.b1 |
D040921.1 | TWP/SONDE/C2 - RH sensor failure below 9km | twpsondewnpnC2.b1 |
D040921.2 | TWP/SONDE/C2 - Bad RH values aloft | twpsondewnpnC2.b1 |
D041011.3 | TWP/SONDE/C1 - Bad RH at beginning of sounding | twpsondewnpnC1.b1 |
D041130.1 | NSA/SONDE/C1 - Test sounding using RS80H | nsasondewnpnC1.b1 |
D041213.5 | NSA/SONDE/C1 - Incorrect surface altitude | nsasondeC1.00, nsasondewnpnC1.b1 |
D050105.1 | TWP/SONDE/C1 - Bad RH at beginning of sounding | twpsondewnpnC1.b1 |
D050201.2 | TWP/SONDE/C1 - Bad RH at beginning of sounding | twpsondewnpnC1.b1 |
D050321.4 | NSA/SONDE/C1 - Bad temperature | nsasondewnpnC1.b1 |
D050913.3 | TWP/SONDE/C2 - Bad RH sensor | twpsondewnpnC2.b1 |
D051122.2 | TWP/SONDE/C2 - Broken temperature sensor | twpsondewnpnC2.b1 |
D051219.2 | TWP/SONDE/C2 - Broken temperature sensor | twpsondewnpnC2.b1 |
D060308.1 | TWP/SONDE/C2 - Broken temperature sensor | twpsondewnpnC2.b1 |
D060403.2 | TWP/SONDE/C2 - Broken temperature sensor | twpsondewnpnC2.b1 |
D060418.1 | TWP/SONDE/C2 - Bad RH in lower 8km | twpsondewnpnC2.b1 |
D060803.2 | NSA/SONDE/C1 - Noisy/Unstable RH and dew point data | nsasondewnpnC1.b1 |
D060811.1 | NSA/SONDE/C1 - Bad surface RH and temperature values | nsasondewnpnC1.b1 |
D060928.1 | NSA/SONDE/C1 - RH values offset due to error in ground check | nsasondewnpnC1.b1 |
D060928.4 | NSA/SONDE/C1 - Increased precision for alt, dp, pres, rh, tdry | nsasondewnpnC1.b1 |
D061011.1 | NSA/SONDE/C1 - Incorrect surface values of T and RH | nsasondewnpnC1.b1 |
D061114.3 | NSA/SONDE/C1 - RH sensor failure | nsasondewnpnC1.b1 |
D990124.2 | SGP/SONDE - Dry bias in sonde RH | sgpsondeB1.00, sgpsondeB1.a0, sgpsondeB1.a1, sgpsondeB4.00, sgpsondeB4.a0, sgpsondeB4.a1, sgpsondeB5.00, sgpsondeB5.a0, sgpsondeB5.a1, sgpsondeB6.00, sgpsondeC1.00, sgpsondeC1.a0, sgpsondeC1.a1, DsgpsondeB1.00, DsgpsondeB1.a0, DsgpsondeB1.a1, DsgpsondeB4.00, DsgpsondeB4.a0, DsgpsondeB4.a1, DsgpsondeB5.00, DsgpsondeB5.a0, DsgpsondeB5.a1, DsgpsondeC1.00, DsgpsondeC1.a0, DsgpsondeC1.a1, sgpsondeptuC1.00, DsgpsondeptuB1.00, DsgpsondeptuB4.00, DsgpsondeptuB5.00, DsgpsondeptuB6.00, DsgpsondeptuC1.00, sgpsondewnpnB1.a0, sgpsondewnpnB1.a1, sgpsondewnpnB4.a0, sgpsondewnpnB4.a1, sgpsondewnpnB5.a0, sgpsondewnpnB5.a1, sgpsondewnpnB6.a0, sgpsondewnpnB6.a1, sgpsondewnpnC1.a0, sgpsondewnpnC1.a1, sgpsondewnprC1.a0, sgpsondewnprC1.a1, sgpsondewrpnB1.00, sgpsondewrpnB1.a0, sgpsondewrpnB1.a1, sgpsondewrpnB4.00, sgpsondewrpnB4.a0, sgpsondewrpnB4.a1, sgpsondewrpnB5.00, sgpsondewrpnB5.a0, sgpsondewrpnB5.a1, sgpsondewrpnB6.00, sgpsondewrpnB6.a0, sgpsondewrpnB6.a1, sgpsondewrpnC1.00, sgpsondewrpnC1.a0, sgpsondewrpnC1.a1, sgpsondewrprB1.00, sgpsondewrprB1.a0, sgpsondewrprB1.a1, sgpsondewrprB4.00, sgpsondewrprB4.a0, sgpsondewrprB4.a1, sgpsondewrprB5.00, sgpsondewrprB5.a0, sgpsondewrprB5.a1, sgpsondewrprC1.00, sgpsondewrprC1.a0, sgpsondewrprC1.a1, DsgpsondeptucalcB1.c1, DsgpsondeptucalcB4.c1, DsgpsondeptucalcB5.c1, DsgpsondeptucalcC1.c1, DsgpsondenogcwrpnB1.c1, DsgpsondenogcwrpnB4.c1, DsgpsondenogcwrpnB5.c1, DsgpsondenogcwrpnC1.c1, DsgpsondenogcptucalcB1.c1, DsgpsondenogcptucalcB4.c1, DsgpsondenogcptucalcB5.c1, DsgpsondenogcptucalcC1.c1 |
Start Date | Start Time | End Date | End Time |
---|---|---|---|
12/22/1998 | 0000 | 03/03/1999 | 2359 |
Subject: | TWP/C2/Sonde Missing Data |
DataStreams: | twpsondeC2.00, twpsondewnpnC2.00, twpsondewnpnC2.a0, twpsondewnpnC2.a1 |
Description: | There were no sondes launced during this period because there was no helium on site and the hydrogen generator was not working. The hydrogen generator was repaired and launches resumed. |
Measurements: | twpsondeC2.00:
twpsondewnpnC2.a0:
twpsondewnpnC2.00:
twpsondewnpnC2.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
11/26/1998 | 0000 | 12/22/1998 | 2359 |
Subject: | TWP/SONDE/C2 - Missing Winds |
DataStreams: | twpsondewnpnC2.a0, twpsondewnpnC2.a1 |
Description: | About half of the soundings in November-December exhibited drop-outs in the winds. These dropouts were typically over a depth of 1-2 km. Sometimes the dropout occurred at the surface, sometimes at the top of the sounding and sometimes in the middle. These gaps occurred on: 19981126 19981129 19981206 19981209 19981210 19981211 19981212 19981221 19981222 |
Measurements: | twpsondewnpnC2.a0:
twpsondewnpnC2.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
11/21/1998 | 0000 | 11/25/1998 | 2359 |
Subject: | TWP/C2/Balloon Soundings: Missing Flights |
DataStreams: | twpsondewnpnC2.a0, twpsondewnpnC2.a1 |
Description: | No sondes were launched during this period for reasons unknown. |
Measurements: | twpsondewnpnC2.a0:
twpsondewnpnC2.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
08/28/1997 | 0455 | 06/22/2000 | 2359 |
Subject: | TWP/C1 - Incorrect elevation reported in Manus Data |
DataStreams: | twpsondewnpnC1.a1 |
Description: | (From Bill Clements) We have been using 6m MSL as the station elevation of Momote (Manus). This was based on information posted near the station barometer in the Momote Weather Service Office. It turns out that the official WMO station elevation for Momote is 4m MSL and the upper air elevation is 5m MSL. All Manus instruments except the sonde station are at 4m MSL. The sonde launching station is at 5m MSL. |
Measurements: | twpsondewnpnC1.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
12/04/1997 | 2239 | 12/04/1997 | 2240 |
Subject: | TWP/C1/Balloon Soundings Maximum Altitude |
DataStreams: | twpsondewnpnC1.a0, twpsondewnpnC1.a1 |
Description: | Only surface data included in this data file. |
Measurements: | twpsondewnpnC1.a0:
twpsondewnpnC1.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
12/08/1997 | 2244 | 12/08/1997 | 2245 |
Subject: | TWP/C1/Balloon Soundings Maximum Altitude |
DataStreams: | twpsondewnpnC1.a0, twpsondewnpnC1.a1 |
Description: | Only surface data included in this data file. |
Measurements: | twpsondewnpnC1.a0:
twpsondewnpnC1.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
12/17/1997 | 2217 | 12/17/1997 | 2218 |
Subject: | TWP/C1/Balloon Soundings Maximum Altitude |
DataStreams: | twpsondewnpnC1.a0, twpsondewnpnC1.a1 |
Description: | Only surface data included in this data file. |
Measurements: | twpsondewnpnC1.a0:
twpsondewnpnC1.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
01/31/1998 | 2241 | 01/31/1998 | 2242 |
Subject: | TWP/C1/Balloon Soundings Maximum Altitude |
DataStreams: | twpsondewnpnC1.a0, twpsondewnpnC1.a1 |
Description: | Only surface data included in this data file. |
Measurements: | twpsondewnpnC1.a0:
twpsondewnpnC1.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
02/16/1998 | 2213 | 02/16/1998 | 2214 |
Subject: | TWP/C1/Balloon Soundings Maximum Altitude |
DataStreams: | twpsondewnpnC1.a0, twpsondewnpnC1.a1 |
Description: | This sonde only reached a height of 0.3 km. |
Measurements: | twpsondewnpnC1.a0:
twpsondewnpnC1.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
11/20/1998 | 0000 | 11/27/1998 | 0000 |
Subject: | TWP/C1 - Generator Problem |
DataStreams: | twpmplC1.a1, twpwsiC1.00, twpmfrsrC1.a0, twpmfrsrC1.a1, twpmfrsrC1.b1, twpmwrlosC1.a1, twpmwrlosC1.b1, twpmwrtipC1.a1, twpmwrtipC1.b1, twpvceil25kC1.a1, twpvceil25kC1.b1, twpsondewnpnC1.a0, twpsondewnpnC1.a1 |
Description: | On November 18 the generator was turned off due to a fault in the oil pressure sensor. It had been having trouble for at least a day prior to the manual shut-down. ADaM, the MPL, and the WSI were also shut down to prevent an unscheduled power cycle. As a result, there is a block of missing data from November 20-27 for all of the instruments except those connected to the Zeno loggers (SKYRAD, GNDRAD, SMET). |
Measurements: | twpmplC1.a1:
twpsondewnpnC1.a0:
twpmfrsrC1.a1:
twpvceil25kC1.a1:
twpmfrsrC1.b1:
twpmfrsrC1.a0:
twpwsiC1.00:
twpsondewnpnC1.a1:
twpvceil25kC1.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
12/12/2000 | 2330 | 12/12/2000 | 2330 |
Subject: | SGP/SONDE/B1 - Incorrect surface temperature |
DataStreams: | sgpsondewnpnB1.00, sgpsondewnpnB1.a0, sgpsondewnpnB1.a1 |
Description: | The operator entered 8.1 degC as the surface temperature for this sounding instead of -8.1 degC. This is the only value affected. |
Measurements: | sgpsondewnpnB1.00:
sgpsondewnpnB1.a0:
sgpsondewnpnB1.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
12/16/2000 | 1430 | 12/16/2000 | 1700 |
Subject: | SGP/SONDE/B1 - Bad sounding data (incorrect calibration?) |
DataStreams: | sgpsondewnpnB1.00, sgpsondewnpnB1.a0, sgpsondewnpnB1.a1 |
Description: | I'm not sure what happened here but the temperature data for this sounding clearly are wrong. Along with the missing humidity data and the problems the operator reported with his previous sounding it looks as if all the data in this file are bad. It may be that the sensor was damaged at launch (it was very windy). |
Measurements: | sgpsondewnpnB1.00:
sgpsondewnpnB1.a0:
sgpsondewnpnB1.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
11/05/1998 | 2249 | 11/19/1998 | 2359 |
Subject: | TWP/C2 Installation |
DataStreams: | twpsondewnpnC2.00, twpsondewnpnC2.a0, twpsondewnpnC2.a1 |
Description: | The Nauru ARCS was installed during the period September-November 1998. Data were being collected by the end of October, but for the first several weeks of November, the site was undergoing considerable change, so data from that period should be used with caution. The official site dedication occured on November 20. Most on-site activity ended following the dedication so we will consider November 20 to be the beginning of the Nauru operations. The last members of the installation team left Nauru on November 24. |
Measurements: | twpsondewnpnC2.a0:
twpsondewnpnC2.00:
twpsondewnpnC2.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
11/03/1997 | 0000 | 06/22/2000 | 2359 |
Subject: | TWP/C1 - Incorrect elevation reported in Manus Data |
DataStreams: | twpsondewnpnC1.a1 |
Description: | (From Bill Clements) We have been using 6m MSL as the station elevation of Momote (Manus). This was based on information posted near the station barometer in the Momote Weather Service Office. It turns out that the official WMO station elevation for Momote is 4m MSL and the upper air elevation is 5m MSL. All Manus instruments except the sonde station are at 4m MSL. The sonde launching station is at 5m MSL. |
Measurements: | twpsondewnpnC1.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
11/07/2002 | 1130 | 11/07/2002 | 1316 |
11/07/2002 | 1429 | 11/07/2002 | 1629 |
11/07/2002 | 1730 | 11/07/2002 | 1930 |
11/07/2002 | 2029 | 11/07/2002 | 2239 |
11/07/2002 | 2331 | 11/08/2002 | 0131 |
Subject: | SGP/SONDE/B4 - Soundings contaminated by interference |
DataStreams: | sgplssondeB4.c1, sgpqmemwrcolB4.c1, sgpsondewnpnB4.a1, sgpsondewnpnB4.b1 |
Description: | These five soundings, done in succession on 11/07/2002 as part of the SCM/IOP are contaminated by interference. I can't tell whether the problem has to do with improper tuning of the radiosondes, inadequate frequency separation among radiosondes launched from different locations, or some other operator problem. I suspect that there is an operator component to the difficulty because the surface pressure is given as an unreasonably low 896.6 hPa on the 1730 sounding and 886.1 hPa on the 2331 sounding. This may indicate that the ground station was locked another station's radiosonde rather than on the B4 radiosonde. |
Measurements: | sgplssondeB4.c1:
sgpqmemwrcolB4.c1:
sgpsondewnpnB4.a1:
sgpsondewnpnB4.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
11/10/2002 | 1824 | 11/10/2002 | 1848 |
Subject: | SGP/SONDE/B4 - Possible interference in B4 sounding 20021110.1729 |
DataStreams: | sgpsondeB4.00, sgpsondewnpnB4.a1, sgpsondewnpnB4.b1 |
Description: | There is a strange inversion aloft in the subject sounding. The temperature goes from -56.3 degC to -51.5 degC in less than two minutes (approximately .72 km). This is somewhat below the estimated tropopause height. I suspect this may be an interference problem, but note that both the recorded pressure and RH values are reasonably continuous. More accurate assessment would require analysis of the absolutely raw binary data; something that would require effort beyond the limits of my IM funding. |
Measurements: | sgpsondeB4.00:
sgpsondewnpnB4.a1:
sgpsondewnpnB4.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
11/14/2002 | 0830 | 11/14/2002 | 1010 |
Subject: | SGP/SONDE/B4 - B4 sounding contaminated by interference |
DataStreams: | sgpsondeB4.00, sgpsondewnpnB4.a1, sgpsondewnpnB4.b1 |
Description: | Much of this sounding is contaminated, apparently by interference from another sonde signal. It is still no clear why this seems to happen more frequently at B4 than the other sites, especially since the wind seems to have been from the west and B4 should be the most upwind station. |
Measurements: | sgpsondeB4.00:
sgpsondewnpnB4.a1:
sgpsondewnpnB4.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
11/18/2002 | 2043 | 11/18/2002 | 2229 |
Subject: | SGP/SONDE/B1 - Temperature sensor failed |
DataStreams: | sgpsondewnpnB1.a1, sgpsondewnpnB1.b1 |
Description: | It appears that the temperature sensor on this sonde broke shortly after launch with the effect that the temperatures read approximately 30 degC too low. Other measurements that do not rely on the temperature, for example pressure and wind velocity, should be OK. |
Measurements: | sgpsondewnpnB1.b1:
sgpsondewnpnB1.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
09/18/2002 | 1137 | 09/18/2002 | 1301 |
09/24/2002 | 0129 | 09/24/2002 | 0204 |
09/24/2002 | 0220 | 09/24/2002 | 0352 |
11/23/2002 | 2330 | 11/24/2002 | 0108 |
11/25/2002 | 2337 | 11/26/2002 | 0001 |
12/16/2002 | 1138 | 12/16/2002 | 1248 |
12/22/2002 | 0136 | 12/22/2002 | 0204 |
12/24/2002 | 2331 | 12/25/2002 | 0112 |
12/27/2002 | 2344 | 12/28/2002 | 0131 |
03/28/2003 | 0214 | 03/28/2003 | 0339 |
04/22/2003 | 2341 | 04/23/2003 | 0122 |
04/23/2003 | 1129 | 04/23/2003 | 1308 |
04/24/2003 | 2358 | 04/25/2003 | 0126 |
06/02/2003 | 1134 | 06/02/2003 | 1321 |
06/06/2003 | 2335 | 06/07/2003 | 0057 |
06/09/2003 | 2340 | 06/10/2003 | 0116 |
06/11/2003 | 2345 | 06/12/2003 | 0112 |
06/14/2003 | 1133 | 06/14/2003 | 1300 |
06/26/2003 | 2335 | 06/27/2003 | 0114 |
09/27/2003 | 2327 | 09/28/2003 | 0132 |
Subject: | TWP/SONDE/C2 - Broken Temperature Sensor |
DataStreams: | twpsondewnpnC2.a1, twpsondewnpnC2.b1 |
Description: | The temperature sensors on these radiosondes broke at launch. All the temperature-related data are incorrect. |
Measurements: | twpsondewnpnC2.b1:
twpsondewnpnC2.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
09/18/2002 | 2334 | 09/19/2002 | 0111 |
09/21/2002 | 2330 | 09/22/2002 | 0059 |
10/01/2002 | 2349 | 10/02/2002 | 0117 |
10/13/2002 | 1139 | 10/13/2002 | 1303 |
10/18/2002 | 2358 | 10/19/2002 | 0113 |
05/23/2003 | 2330 | 05/24/2003 | 0135 |
06/14/2003 | 2330 | 06/15/2003 | 0147 |
06/22/2003 | 1159 | 06/22/2003 | 1332 |
06/22/2003 | 2349 | 06/23/2003 | 0110 |
06/23/2003 | 1146 | 06/23/2003 | 1323 |
06/25/2003 | 2342 | 06/26/2003 | 0118 |
06/28/2003 | 2330 | 06/29/2003 | 0056 |
06/29/2003 | 1134 | 06/29/2003 | 1312 |
Subject: | TWP/SONDE/C1 - Broken Temperature Sensor |
DataStreams: | twpsondewnpnC1.a1, twpsondewnpnC1.b1 |
Description: | The temperature sensor on these radiosondes broke after launch. All the temperature related data are incorrect. |
Measurements: | twpsondewnpnC1.b1:
twpsondewnpnC1.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
12/21/2002 | 2336 | 12/22/2002 | 0119 |
Subject: | TWP/Sonde/C1 - Bad RH Values |
DataStreams: | twpsondewnpnC1.a1, twpsondewnpnC1.b1 |
Description: | The RH values from the surface to approximately 11.5 km oscillate between reasonable values and zero. This is apparently caused by a failure in the RH sensor heating process. Although the oscillation stops when the heating stops (at temperatures below ~ -45degC) I think the values must be viewed as suspect. |
Measurements: | twpsondewnpnC1.b1:
twpsondewnpnC1.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
04/13/2003 | 0124 | 04/13/2003 | 0200 |
Subject: | TWP/SONDE/C2 - Bad RH Data (AIRS Validation Sonde) |
DataStreams: | twpsondewnpnC2.a1, twpsondewnpnC2.b1 |
Description: | The RH sensor heating circuit failed on this sonde. This results in oscillation of reported RH between reasonable values and values near zero. This was an AIRS validation sounding. |
Measurements: | twpsondewnpnC2.b1:
twpsondewnpnC2.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
04/08/2003 | 2347 | 04/09/2003 | 0003 |
Subject: | TWP/SONDE/C1 - Questionable RH |
DataStreams: | twpsondewnpnC1.a1, twpsondewnpnC1.b1 |
Description: | It appears that the RH sensor heating circuit failed during this portion of the sounding (approximately between 5km and 10km). The RH oscillates rapidly between low (~5 %RH) and not so low (~50 %RH) and the oscillation seems to stop when the temperature is below ~35 degC. According to Vaisala these are symptoms of failure in the ASIC (application specific integrated circuit) that controls the heating. |
Measurements: | twpsondewnpnC1.b1:
twpsondewnpnC1.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
04/29/2003 | 1123 | 04/29/2003 | 1205 |
Subject: | TWP/SONDE/C1 - Bad RH |
DataStreams: | twpsondewnpnC1.a1, twpsondewnpnC1.b1 |
Description: | The RH sensor heating circuit failed on this radiosonde. The RH-related values obtained between 0 and 10000 meters oscillate between near-zero and reasonable ambient values. Above 10000 the RH values are likely correct. |
Measurements: | twpsondewnpnC1.b1:
twpsondewnpnC1.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
05/12/2003 | 2300 | 05/13/2003 | 0045 |
Subject: | NSA/SONDE/C1 - Broken temperature sensor |
DataStreams: | nsasondewnpnC1.a1, nsasondewnpnC1.b1 |
Description: | It appears that the temperature sensor on this radiosonde broke after launch. There is a sudden drop of 12 degC in 2 seconds and the remaining tdry values seem to be about 30 degC low. |
Measurements: | nsasondewnpnC1.b1:
nsasondewnpnC1.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
05/23/2003 | 2330 | 05/24/2003 | 0135 |
Subject: | TWP/SONDE/C1 - Broken temperature sensor |
DataStreams: | twpsondewnpnC1.a1, twpsondewnpnC1.b1 |
Description: | The temperature sensor on this radiosonde broke after launch. All the temperature-related data are incorrect. |
Measurements: | twpsondewnpnC1.b1:
twpsondewnpnC1.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
06/03/2003 | 2339 | 06/04/2003 | 0016 |
Subject: | TWP/SONDE/C2 - Failure of RH sensor |
DataStreams: | twpsondewnpnC2.a1, twpsondewnpnC2.b1 |
Description: | It appears that the RH sensor heating circuit failed during this sounding. The RH oscillates rapidly between low (~0 %RH) and not so low (ambient %RH) and the oscillation seems to stop when the temperature is below ~35 degC. According to Vaisala these are symptoms of failure in the ASIC (application specific integrated circuit) that controls the heating. |
Measurements: | twpsondewnpnC2.b1:
twpsondewnpnC2.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/02/2003 | 0232 | 10/02/2003 | 0300 |
Subject: | TWP/SONDE/C2 - Strange problem with data - |
DataStreams: | twpsondeC2.00, twpsondewnpnC2.00, twpsondewnpnC2.b1 |
Description: | This is very strange. The data has what appears to be a pressure jump at launch (from 1007.2 to 956.5 hPa) but the sounding temperature and RH data clearly look to be interpolated between the surface and tropopause. By examining the absolutely raw data, I found that the system assigned an elapsed time of 408 seconds (since system start up) to the launch point, but there is no raw data between 410 and 532 seconds. The raw pressure value at 410 seconds is 1007.6 hPa and that at 532 seconds is 40.9 hPa! Unless this sounding was done by using a rocket-powered balloon (maybe even then), it would be impossible for the sonde to get to 40.9 hPa in 2 minutes. Because the apparent gap is only two minutes, the system was able to interpolate but is not sophisticated enough to understand that the limits of the interpolation are unreasonable. I can't imagine what went wrong - I've not seen anything like this before. |
Measurements: | twpsondeC2.00:
twpsondewnpnC2.b1:
twpsondewnpnC2.00:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/22/2003 | 0025 | 10/22/2003 | 0155 |
10/22/2003 | 2340 | 10/23/2003 | 0121 |
Subject: | TWP/SONDE/C2 - RH sensor bad |
DataStreams: | twpsondewnpnC2.b1 |
Description: | It appears that the RH sensor heating circuits failed during these soundings. The RH oscillates rapidly between low (~0 %RH) and not so low (ambient %RH) and the oscillation seems to stop when the temperature is below ~35 degC. According to Vaisala these are symptoms of failure in the ASIC (application specific integrated circuit) that controls the heating. |
Measurements: | twpsondewnpnC2.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/13/2003 | 0040 | 10/13/2003 | 0203 |
11/08/2003 | 2335 | 11/09/2003 | 0215 |
11/18/2003 | 1205 | 11/18/2003 | 1340 |
11/19/2003 | 1156 | 11/19/2003 | 1346 |
11/21/2003 | 0044 | 11/21/2003 | 0113 |
12/20/2003 | 1225 | 12/20/2003 | 1408 |
12/21/2003 | 0056 | 12/21/2003 | 0126 |
12/21/2003 | 1155 | 12/21/2003 | 1344 |
12/23/2003 | 0042 | 12/23/2003 | 0212 |
12/23/2003 | 1137 | 12/23/2003 | 1259 |
12/23/2003 | 2342 | 12/24/2003 | 0132 |
01/08/2004 | 1135 | 01/08/2004 | 1309 |
01/09/2004 | 1157 | 01/09/2004 | 1342 |
01/09/2004 | 1359 | 01/09/2004 | 1537 |
01/12/2004 | 2342 | 01/13/2004 | 0214 |
01/16/2004 | 1409 | 01/16/2004 | 1548 |
01/16/2004 | 2337 | 01/17/2004 | 0109 |
01/18/2004 | 1135 | 01/18/2004 | 1256 |
01/19/2004 | 0223 | 01/19/2004 | 0346 |
01/19/2004 | 2329 | 01/20/2004 | 0157 |
01/21/2004 | 1252 | 01/21/2004 | 1400 |
01/22/2004 | 0052 | 01/22/2004 | 0227 |
01/23/2004 | 1137 | 01/23/2004 | 1319 |
01/26/2004 | 1202 | 01/26/2004 | 0146 |
02/17/2004 | 1406 | 02/17/2004 | 1536 |
02/26/2004 | 1221 | 02/26/2004 | 1350 |
03/09/2004 | 1145 | 03/09/2004 | 1315 |
03/14/2004 | 1131 | 03/14/2004 | 1300 |
03/22/2004 | 1134 | 03/22/2004 | 1300 |
03/29/2004 | 2332 | 03/30/2004 | 0047 |
03/30/2004 | 2334 | 03/31/2004 | 0059 |
04/11/2004 | 2348 | 04/12/2004 | 0120 |
05/01/2004 | 2335 | 05/02/2004 | 0110 |
05/02/2004 | 2336 | 05/03/2004 | 0109 |
05/13/2004 | 2334 | 05/14/2004 | 0112 |
05/14/2004 | 1406 | 05/14/2004 | 1411 |
06/07/2004 | 0224 | 06/07/2004 | 0351 |
06/25/2004 | 1146 | 06/25/2004 | 1328 |
07/02/2004 | 0059 | 07/02/2004 | 0217 |
07/20/2004 | 0220 | 07/20/2004 | 0358 |
07/24/2004 | 1235 | 07/24/2004 | 1355 |
08/22/2004 | 1144 | 08/22/2004 | 1207 |
09/08/2004 | 1425 | 09/08/2004 | 1605 |
09/08/2004 | 2338 | 09/08/2004 | 2345 |
10/18/2004 | 2346 | 10/19/2004 | 0128 |
11/29/2004 | 2321 | 11/30/2004 | 0105 |
12/08/2004 | 1143 | 12/08/2004 | 1306 |
12/30/2004 | 1130 | 12/30/2004 | 1239 |
Subject: | TWP/SONDE/C2 - Broken temperature sensors |
DataStreams: | twpsondewnpnC2.b1 |
Description: | The temperature sensors on these radiosondes broke after launch. All temperature-related data are incorrect. |
Measurements: | twpsondewnpnC2.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
02/04/2004 | 1147 | 02/04/2004 | 1337 |
Subject: | TWP/SONDE/C2 - Questionable rH data |
DataStreams: | twpsondewnpnC2.b1 |
Description: | It appears that the RH sensor heating circuit failed during this sounding. The RH oscillates rapidly between low (~0 %RH) and not so low (ambient %RH) and the oscillation seems to stop when the temperature is below ~35 degC. According to Vaisala these are symptoms of failure in the ASIC (application specific integrated circuit) that controls the heating. |
Measurements: | twpsondewnpnC2.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
02/18/2004 | 0035 | 02/18/2004 | 0205 |
Subject: | TWP/SONDE/C2 - Bad RH sensor |
DataStreams: | twpsondewnpnC2.b1 |
Description: | It appears that the RH sensor heating circuit failed during this sounding. The RH oscillates rapidly between low (~0 %RH) and not so low (ambient %RH) and the oscillation seems to stop when the temperature is below ~35 degC. According to Vaisala these are symptoms of failure in the ASIC (application specific integrated circuit) that controls the heating. |
Measurements: | twpsondewnpnC2.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
02/07/2004 | 2342 | 02/08/2004 | 0115 |
02/09/2004 | 1133 | 02/09/2004 | 1233 |
04/05/2004 | 2332 | 04/06/2004 | 0105 |
04/22/2004 | 1156 | 04/22/2004 | 1317 |
04/24/2004 | 1130 | 04/24/2004 | 1312 |
04/29/2004 | 1137 | 04/29/2004 | 1312 |
04/30/2004 | 2336 | 05/01/2004 | 0112 |
05/03/2004 | 2331 | 05/04/2004 | 0105 |
05/05/2004 | 1135 | 05/05/2004 | 1319 |
05/07/2004 | 1132 | 05/07/2004 | 1315 |
05/11/2004 | 1142 | 05/11/2004 | 1311 |
05/12/2004 | 1145 | 05/12/2004 | 1206 |
05/18/2004 | 1130 | 05/18/2004 | 1321 |
07/10/2004 | 1130 | 07/11/2004 | 1255 |
07/13/2004 | 1139 | 07/13/2004 | 1320 |
07/16/2004 | 2346 | 07/17/2004 | 0107 |
07/22/2004 | 2355 | 07/23/2004 | 0140 |
07/26/2004 | 2341 | 07/27/2004 | 0115 |
08/14/2004 | 2330 | 08/15/2004 | 0104 |
08/22/2004 | 2335 | 08/23/2004 | 0105 |
09/05/2004 | 2340 | 09/06/2004 | 0119 |
09/14/2004 | 2328 | 09/14/2004 | 2329 |
09/17/2004 | 2332 | 09/18/2004 | 0102 |
10/28/2004 | 2336 | 10/29/2004 | 0057 |
11/28/2004 | 2352 | 11/29/2004 | 0044 |
Subject: | TWP/SONDE/C1 - Broken temperature sensor |
DataStreams: | twpsondewnpnC1.b1 |
Description: | The temperature sensor on these radiosondes broke after launch All the temperature-related data are incorrect. |
Measurements: | twpsondewnpnC1.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
02/06/2004 | 2341 | 02/06/2004 | 0130 |
Subject: | TWP/SONDE/C1 - Bad RH sensors |
DataStreams: | twpsondewnpnC1.b1 |
Description: | It appears that the RH sensor heating circuit failed during this portion of the sounding (approximately between 0km and 12km). The RH oscillates rapidly in a 20% range and the oscillation seems to stop when the temperature is below ~45 degC. These are symptoms of failure in the ASIC (application specific integrated circuit) that controls the heating. |
Measurements: | twpsondewnpnC1.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
04/21/2004 | 1232 | 04/21/2004 | 1248 |
Subject: | TWP/SONDE/C2 - Bad RH values aloft |
DataStreams: | twpsondewnpnC2.b1 |
Description: | It appears that the RH sensor heating circuit on this sonde failed about 24 minutes into the flight. The RH values look reasonable, though somewhat noisy, from the surface to approximately 6.9 km (439 hPa) at which point they begin to oscillate between 0 and 100 %. This behavior stops when the sonde reaches approximately 11.5km (232 hPa) when the air temperature drops below -40 degC. The oscillation stops at that point, though the RH remains higher than might be expected even under supersaturated conditions. |
Measurements: | twpsondewnpnC2.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
05/28/2003 | 2330 | 05/29/2003 | 0010 |
Subject: | TWP/SONDE/C1 - Bad RH sensor |
DataStreams: | twpsondewnpnC1.a1, twpsondewnpnC1.b1 |
Description: | It appears that the RH sensor heating circuit failed during this portion of the sounding (approximately between the surface and 11km). The RH oscillates rapidly between low (~0 %RH) and high (~80 %RH) and the oscillation seems to stop when the temperature is below ~40 degC. According to Vaisala these are symptoms of failure in the ASIC (application specific integrated circuit) that controls the heating. |
Measurements: | twpsondewnpnC1.b1:
twpsondewnpnC1.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
06/03/2004 | 1132 | 06/03/2004 | 1212 |
Subject: | TWP/SONDE/C1 - Bad RH at beginning of sounding |
DataStreams: | twpsondewnpnC1.b1 |
Description: | It appears that the RH sensor heating circuit failed during this portion of the sounding (approximately between 0km and 11km). The RH oscillates rapidly between low (~15 %RH) and not so low (~50 %RH) and the oscillation seems to stop when the temperature is below ~40 degC. According to Vaisala these are symptoms of failure in the ASIC (application specific integrated circuit) that controls the heating. |
Measurements: | twpsondewnpnC1.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
06/04/2004 | 0010 | 06/23/2004 | 2330 |
Subject: | TWP/SONDE/C1 - Bad RH at beginning of sounding |
DataStreams: | twpsondewnpnC1.b1 |
Description: | It appears that the RH sensor heating circuit failed during this portion of the sounding (approximately between 0km and 11km). The RH oscillates rapidly between low (~0 %RH) and not so low (~80 %RH) and the oscillation seems to stop when the temperature is below ~40 degC. According to Vaisala these are symptoms of failure in the ASIC (application specific integrated circuit) that controls the heating. |
Measurements: | twpsondewnpnC1.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
06/21/2004 | 0010 | 06/21/2004 | 0011 |
Subject: | TWP/SONDE/C1 - Bad RH in short interval aloft |
DataStreams: | twpsondewnpnC1.b1 |
Description: | It appears that the RH sensor heating circuit on this sonde failed about 31 minutes into the flight. The RH values look reasonable from the surface to approximately 8.25 km at which point they begin to oscillate between 0 and 40%. This behavior stops when the sonde reaches approximately 11.0km when the air temperature drops below -40 degC. The oscillation stops at that point, though the RH remains higher than might be expected even under supersaturated conditions. |
Measurements: | twpsondewnpnC1.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
06/30/2004 | 1130 | 06/30/2004 | 1204 |
Subject: | TWP/SONDE/C1 - Bad RH at beginning of sounding |
DataStreams: | twpsondewnpnC1.b1 |
Description: | It appears that the RH sensor heating circuit failed during this portion of the sounding (approximately between 0km and 11km). The RH oscillates rapidly between low (~2 %RH) and not so low (~90 %RH) and the oscillation seems to stop when the temperature is below ~40 degC. According to Vaisala these are symptoms of failure in the ASIC (application specific integrated circuit) that controls the heating. |
Measurements: | twpsondewnpnC1.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
07/10/2004 | 1238 | 07/10/2004 | 1315 |
Subject: | TWP/SONDE/C2 - RH sensor failure near surface |
DataStreams: | twpsondewnpnC2.b1 |
Description: | It appears that the RH sensor heating circuit failed during this sounding. The RH oscillates rapidly between low (~0 %RH) and not so low (ambient %RH) and the oscillation seems to stop when the temperature is below ~35 degC. According to Vaisala these are symptoms of failure in the ASIC (application specific integrated circuit) that controls the heating. |
Measurements: | twpsondewnpnC2.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
08/12/2004 | 0044 | 08/12/2004 | 0233 |
Subject: | TWP/SONDE/C2 - Operator used wrong calibration tape |
DataStreams: | twpsondewnpnC2.b1 |
Description: | It appears as though the opperator used the wrong calibration tape for this sounding. The primary symptom is a jump in temperature from a surface value of 30.1 degC to the first value aloft of 61.0 degC. Secondly, the recorded serial number for this sounding is Z1430179 which is the same serial number recorded for the previous sounding. This problem points to three failures of procedure (I have notified TWP site ops by e-mail). The first failure is using the wrong tape. The second failure is not checking the radiosonde values before launch which relates to the third failure of not entering the radiosonde values as the surface values of the sounding. |
Measurements: | twpsondewnpnC2.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
08/20/2004 | 1844 | 08/20/2004 | 1925 |
Subject: | NSA/SONDE/C1 - This is a test sounding done using an RS80H radiosonde |
DataStreams: | nsasondewnpnC1.b1 |
Description: | This was a sounding done using an RS80H radiosonde to test a special operational procedure. There is nothing wrong with the data, though users should be aware that the sounding was not done using the current ARM standard RS90 radiosonde. |
Measurements: | nsasondewnpnC1.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
09/16/2004 | 1135 | 09/16/2004 | 1210 |
Subject: | TWP/SONDE/C2 - RH sensor failure below 9km |
DataStreams: | twpsondewnpnC2.b1 |
Description: | It appears that the RH sensor heating circuit failed during this sounding. The RH oscillates rapidly between low (~0 %RH) and not so low (ambient %RH) and the oscillation seems to stop when the temperature is below ~35 degC. According to Vaisala these are symptoms of failure in the ASIC (application specific integrated circuit) that controls the heating. |
Measurements: | twpsondewnpnC2.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
09/17/2004 | 1145 | 09/17/2004 | 1216 |
09/18/2004 | 0058 | 09/18/2004 | 0133 |
09/19/2004 | 1408 | 09/19/2004 | 1447 |
Subject: | TWP/SONDE/C2 - Bad RH values aloft |
DataStreams: | twpsondewnpnC2.b1 |
Description: | It appears that the RH sensor heating circuit on these sondes failed after launch but resume proper operation when the ambient temperature dropped below ~40 degC. |
Measurements: | twpsondewnpnC2.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/08/2004 | 1131 | 10/08/2004 | 1200 |
Subject: | TWP/SONDE/C1 - Bad RH at beginning of sounding |
DataStreams: | twpsondewnpnC1.b1 |
Description: | It appears that the RH sensor heating circuit failed during this portion of the sounding (approximately between 0km and 11km). The RH oscillates rapidly between low (~1 %RH) and high (~80 %RH). According to Vaisala these are symptoms of failure in the ASIC (application specific integrated circuit) that controls the heating. |
Measurements: | twpsondewnpnC1.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
11/29/2004 | 2303 | 11/30/2004 | 0023 |
Subject: | NSA/SONDE/C1 - Test sounding using RS80H |
DataStreams: | nsasondewnpnC1.b1 |
Description: | This is a test sounding done using an old RS80H radiosonde rather than the production RS90 version. Although the sonde functioned normally, the RH data may be subject to a dry bias caused by the age of the sensor and possible contamination. |
Measurements: | nsasondewnpnC1.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
04/28/2002 | 0000 | 02/13/2004 | 2359 |
Subject: | NSA/SONDE/C1 - Incorrect surface altitude |
DataStreams: | nsasondeC1.00, nsasondewnpnC1.b1 |
Description: | The value of the station altitude (relative to mean sea level) is incorrect in all NSA radiosonde files prior to 2/14/2004. The correct value is 8 m. The incorrect value can be different. Prior to 4/24/2002 (in platform nsaisssonde...) it was given as 12 m. From 4/24/2002 to 2/13/2004 (in platform nsasondewnpn...) it is almost always given as 27 m (sometimes [rarely] 17 m). |
Measurements: | nsasondewnpnC1.b1:
nsasondeC1.00:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
12/30/2004 | 2330 | 12/31/2004 | 0108 |
Subject: | TWP/SONDE/C1 - Bad RH at beginning of sounding |
DataStreams: | twpsondewnpnC1.b1 |
Description: | It appears that the RH sensor heating circuit failed during this portion of the sounding (approximately between 0km and 11km). The RH oscillates rapidly between low (~5 %RH) and not so low (~70 %RH) and the oscillation seems to stop when the temperature is below ~40 degC. According to Vaisala these are symptoms of failure in the ASIC (application specific integrated circuit) that controls the heating. |
Measurements: | twpsondewnpnC1.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
01/07/2005 | 2330 | 01/08/2005 | 0102 |
Subject: | TWP/SONDE/C1 - Bad RH at beginning of sounding |
DataStreams: | twpsondewnpnC1.b1 |
Description: | It appears that the RH sensor heating circuit failed during this portion of the sounding (approximately between 0km and 12km). The RH oscillates rapidly between low (~2 %RH) and not so low (~80 %RH) and the oscillation seems to stop when the temperature is below ~40 degC. According to Vaisala these are symptoms of failure in the ASIC (application specific integrated circuit) that controls the heating. |
Measurements: | twpsondewnpnC1.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
03/08/2005 | 2300 | 03/09/2005 | 0033 |
Subject: | NSA/SONDE/C1 - Bad temperature |
DataStreams: | nsasondewnpnC1.b1 |
Description: | Because of strong winds, the radiosonde hit the ground after launch and the temperature sensor broke. The RH and pressure data also should be considered suspect. |
Measurements: | nsasondewnpnC1.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
07/03/2005 | 2350 | 07/04/2005 | 0024 |
07/10/2005 | 2340 | 07/11/2005 | 0021 |
07/19/2005 | 2332 | 07/20/2005 | 0016 |
Subject: | TWP/SONDE/C2 - Bad RH sensor |
DataStreams: | twpsondewnpnC2.b1 |
Description: | It appears that the RH sensor heating circuit failed during this sounding. The RH oscillates rapidly between low (~0 %RH) and not so low (ambient %RH) and the oscillation seems to stop when the temperature is below -50 degC. According to Vaisala these are symptoms of failure in the ASIC (application specific integrated circuit) that controls the heating. |
Measurements: | twpsondewnpnC2.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
11/19/2005 | 2334 | 11/20/2005 | 0153 |
11/21/2005 | 2332 | 11/22/2005 | 0140 |
Subject: | TWP/SONDE/C2 - Broken temperature sensor |
DataStreams: | twpsondewnpnC2.b1 |
Description: | The temperature sensor on this radiosonde broke after launch. All the temperature-related data are incorrect. |
Measurements: | twpsondewnpnC2.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
12/07/2005 | 1153 | 12/07/2005 | 1323 |
Subject: | TWP/SONDE/C2 - Broken temperature sensor |
DataStreams: | twpsondewnpnC2.b1 |
Description: | The temperature sensor on this radiosonde broke after launch. All the temperature-related data are incorrect. |
Measurements: | twpsondewnpnC2.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
01/15/2006 | 1144 | 01/15/2006 | 1328 |
01/19/2006 | 1318 | 01/19/2006 | 1320 |
01/22/2006 | 1149 | 01/22/2006 | 1315 |
02/14/2006 | 0055 | 02/14/2006 | 0207 |
02/21/2006 | 0232 | 02/21/2006 | 0359 |
Subject: | TWP/SONDE/C2 - Broken temperature sensor |
DataStreams: | twpsondewnpnC2.b1 |
Description: | The temperature sensor on this radiosonde broke after launch. All the temperature-related data are incorrect. |
Measurements: | twpsondewnpnC2.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
03/27/2006 | 0043 | 03/27/2006 | 0208 |
Subject: | TWP/SONDE/C2 - Broken temperature sensor |
DataStreams: | twpsondewnpnC2.b1 |
Description: | The temperature sensor on this radiosonde broke after launch. All the temperature-related data are incorrect. |
Measurements: | twpsondewnpnC2.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
04/10/2006 | 0247 | 04/10/2006 | 0314 |
Subject: | TWP/SONDE/C2 - Bad RH in lower 8km |
DataStreams: | twpsondewnpnC2.b1 |
Description: | It appears that the RH sensor heating circuit failed during this sounding. The RH oscillates rapidly between low (~0 %RH) and not so low (ambient %RH) and the oscillation seems to stop when the temperature is below ~35 degC. According to Vaisala these are symptoms of failure in the ASIC (application specific integrated circuit) that controls the heating. |
Measurements: | twpsondewnpnC2.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
07/31/2006 | 0515 | 07/31/2006 | 0523 |
Subject: | NSA/SONDE/C1 - Noisy/Unstable RH and dew point data |
DataStreams: | nsasondewnpnC1.b1 |
Description: | The RH readings during the first 8 minutes of this sounding include three apparently incorrect oscillations to near-zero values. After checking the absolutely raw data, it seems as though this period was excessively noisy, resulting in many missing values. The noise abatted and the remaining sounding values are valid. |
Measurements: | nsasondewnpnC1.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
07/30/2006 | 0522 | 07/30/2006 | 0523 |
08/01/2006 | 0520 | 08/01/2006 | 0521 |
08/04/2006 | 0532 | 08/04/2006 | 0533 |
08/06/2006 | 0528 | 08/06/2006 | 0529 |
08/08/2006 | 0517 | 08/08/2006 | 0518 |
08/09/2006 | 0527 | 08/09/2006 | 0528 |
08/11/2006 | 0525 | 08/11/2006 | 0526 |
08/15/2006 | 0534 | 08/15/2006 | 0535 |
08/17/2006 | 0535 | 08/17/2006 | 0536 |
08/18/2006 | 0516 | 08/18/2006 | 0517 |
08/19/2006 | 0538 | 08/19/2006 | 0539 |
08/19/2006 | 1745 | 08/19/2006 | 1746 |
08/20/2006 | 0532 | 08/20/2006 | 0533 |
08/20/2006 | 1729 | 08/20/2006 | 1730 |
08/21/2006 | 0530 | 08/21/2006 | 0531 |
08/22/2006 | 0524 | 08/22/2006 | 0525 |
Subject: | NSA/SONDE/C1 - Bad surface RH and temperature values |
DataStreams: | nsasondewnpnC1.b1 |
Description: | This is a subtle problem that might escape notice. For the identified sonde launches, the ground station lost its signal between the time it was removed from the ground check set and the time it was launched. As a result, the software, which automatically determines the launch time and surface conditions at time of launch mistakenly used values of temperature and RH representative of the ground check set and the GW rather than of the ambient conditions before launch. The bad values influenced only the first few samples and the remainder of the sounding values are correct. A procedural problem was identified and corrected. |
Measurements: | nsasondewnpnC1.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
07/13/2006 | 0532 | 09/26/2006 | 2359 |
Subject: | NSA/SONDE/C1 - RH values offset due to error in ground check |
DataStreams: | nsasondewnpnC1.b1 |
Description: | Background: After installation of the latest software update , we began performing formal ground checks on RS92 radiosondes. By comparing the radiosonde readings with reference values in a controlled environment, the ground check is intended to ensure that the radiosonde sensors are in calibration before launch. The radisonde values during the ground check process are recorded automatically; the reference values are entered by the operator. If the radiosonde readings vary from the reference values, the system 'corrects' the radiosonde values. In the case of RH, the correction is applied as an offset (true RH = indicated RH + correction). Problem: Some operators misunderstood the ground-check procedure and entered the radiosonde values of RH rather than the reference value (assumed 0%RH), thus, some soundings done during this period have RH values that are different from what they would be if the ground check procedure had been done correctly. Consequence: Because the RH corrections generally are small (averaging about 0.5% RH) and the precision of the reported RH data during this time period is 1% RH, some values will not be affected at all; others will be off by about 1% RH (still within the stated accuracy of the sensor). Furthermore, because entering the radiosonde value as the reference value results in a near zero 'correction,' one may view these soundings as being done without the ground check correction. Also note that the dew point value will be suspect as well. I am attaching below a listing of the soundings that were affected during the indicated time period. Users can see the magnitude of the problem and choose whether or not to apply an offset in RH. Note that application of the offset to the processed RH data (in the netCDF file) will not have the same effect of applying the correction to the absolutely raw data (before processing), but the differences should be insignificant. Also note that the corrections for each sounding are included in the netCDF header information. These attributes are named 'humidity_correction' and 'humidity_correction_2'. The values of RH indicated by the radiosonde while it is in the ground check set are in attributes 'humidity_gc_sonde' and 'humidity_gc_sonde_2.' There is an RH reading for each of the two RH sensors used in the RS92 radiosonde. Here is the list - RH1 and RH2 are the radiosonde readings in the ground check set. Ref is the reference value entered by the operator. The correcte reference value should be 0%. To obtain an approximation to the RH value that would have been recorded if the ground check had been done properly, subtract the Ref value from the indicated RH. YYYYMMDD HHMM SerialNo RH1 RH2 Ref 20060713 0532 B1924431 0.30 0.20 0.30 20060713 1751 B1854963 0.20 0.30 0.30 20060714 0521 B1924425 0.40 0.40 0.40 20060714 1739 B1854206 0.30 0.30 0.30 20060715 0522 B1715127 1.20 1.20 1.20 20060715 1737 B1854966 0.60 0.60 0.60 20060716 0508 B1715126 0.40 0.40 0.40 20060716 1732 B1844098 0.50 0.50 0.50 20060717 0517 B1914170 0.40 0.40 0.40 20060718 0516 B1914173 0.70 0.70 0.70 20060720 0523 B1854149 0.40 0.40 0.40 20060721 0517 B1914153 0.40 0.40 0.40 20060722 0521 B1844097 1.00 1.10 1.10 20060722 1730 B1914174 0.60 0.70 0.70 20060723 0537 B1714439 0.40 0.40 0.40 20060723 1734 B1734155 0.50 0.50 0.50 20060724 0529 B1134336 0.50 0.50 0.50 20060725 0525 B1754099 0.60 0.70 0.70 20060726 0541 B1844108 1.80 1.80 1.80 20060727 0520 B1714382 0.70 0.80 0.70 20060728 0531 B1854116 0.80 0.80 0.80 20060729 0527 B1724027 1.00 1.00 1.00 20060729 1726 B1714392 0.70 0.80 0.80 20060730 0522 B1854100 0.70 0.80 0.80 20060730 1724 B1854764 0.90 1.00 1.00 20060731 0515 B1664086 0.90 0.80 0.90 20060801 0520 B1724758 1.50 1.50 1.50 20060801 1729 B1754116 1.10 1.10 1.10 20060802 0518 B1724516 0.80 0.80 0.80 20060803 0523 B1674148 0.80 0.80 0.80 20060804 0532 B1754092 0.90 0.90 0.90 20060804 1727 B1844117 3.50 3.50 3.50 20060805 0531 B1714741 0.30 0.30 0.30 20060805 1728 B1754098 0.30 0.30 0.30 20060806 0528 B1844115 0.40 0.40 0.40 20060806 1728 B1914161 0.20 0.20 0.20 20060807 0530 B1714549 0.30 0.30 0.30 20060808 0517 B1844107 0.50 0.50 0.50 20060808 1744 B1914166 0.20 0.20 0.20 20060809 0527 B1914164 0.30 0.40 0.40 20060809 1736 B1914163 0.30 0.30 0.30 20060810 0521 B1914160 0.40 0.50 0.50 20060810 1745 B1744671 0.40 0.40 0.40 20060811 0525 B1854965 0.50 0.50 0.50 20060811 1753 B1724131 0.10 0.10 0.10 20060812 0527 B1754104 0.50 0.50 0.50 20060812 1740 B1854256 0.30 0.40 0.40 20060813 0522 B1854240 0.30 0.40 0.40 20060814 0525 B1714106 0.20 0.20 0.20 20060814 1742 B1854106 0.40 0.40 0.40 20060815 0534 B1914169 0.50 0.60 0.60 20060815 1734 B1854233 0.60 0.70 0.70 20060816 0539 B1724791 0.20 0.20 0.20 20060816 1732 B1914171 0.10 0.20 0.20 20060817 0535 B1354283 0.10 0.10 0.10 20060817 1740 B1354574 0.40 0.40 0.40 20060818 0516 B1354633 0.50 0.40 0.50 20060818 1744 B1364673 0.20 0.20 0.20 20060819 0538 B1364126 0.20 0.30 0.30 20060819 1745 B1354598 0.50 0.60 0.60 20060820 0532 B1354290 1.10 1.10 1.10 20060820 1729 B1354317 0.40 0.40 0.40 20060821 0530 B1354545 0.60 0.70 0.70 20060821 1728 B1354516 0.70 0.70 0.70 20060822 0524 B1354619 0.50 0.60 0.60 20060822 1728 B1364377 0.40 0.40 0.40 20060823 0533 B1354309 0.30 0.30 0.30 20060823 1730 B1354527 0.70 0.70 0.70 20060824 0533 B1354230 0.60 0.60 0.60 20060824 1812 B1354587 0.70 0.70 0.70 20060825 0517 B1354614 0.70 0.70 0.70 20060825 1730 B1354630 0.60 0.60 0.60 20060826 0537 B1334114 0.90 0.90 0.90 20060826 1734 B1354246 0.70 0.70 0.70 20060827 0508 B1354534 0.70 0.70 0.70 20060827 1729 B1354618 0.60 0.60 0.60 20060828 0517 B1354115 0.40 0.40 0.40 20060828 1738 B1354206 0.50 0.60 0.60 20060829 0516 B1354617 0.50 0.60 0.60 20060829 1717 B1354622 0.50 0.60 0.60 20060830 0511 B1354314 0.40 0.50 0.50 20060830 1732 B1354537 0.60 0.70 0.70 20060831 1802 B1354239 0.60 0.80 0.80 20060905 1724 B1354626 0.60 0.60 0.60 20060906 0522 B1354525 0.60 0.80 0.80 20060906 1734 B1354107 0.50 0.50 0.50 20060907 0537 B1354543 0.70 0.70 0.70 20060907 1803 B1354586 0.80 0.80 0.80 20060908 0531 B1354519 0.60 0.60 0.60 20060908 1728 B1354224 0.60 0.60 0.60 20060909 0534 B1354532 0.70 0.80 0.80 20060909 1732 B1354513 0.80 0.90 0.90 20060910 0516 B1354125 0.60 0.70 0.60 20060910 1727 B1354110 0.40 0.50 0.50 20060911 0528 B1354235 0.90 0.90 0.90 20060911 1849 B1354514 0.70 0.70 0.70 20060912 0525 B1354124 0.60 0.70 0.70 20060913 0534 B1344478 0.50 0.50 0.50 20060914 0520 B1354226 0.70 0.70 0.70 20060915 0529 B1344459 0.40 0.50 0.50 20060916 0532 B1344469 0.50 0.40 0.50 20060916 1732 B1354106 0.50 0.60 0.60 20060917 0527 B1354210 0.70 0.70 0.70 20060918 0533 B1354087 0.60 0.60 0.60 20060919 0526 B1354097 0.70 0.50 0.60 20060920 0516 B1344462 0.50 0.40 0.50 20060920 1810 B1354536 0.70 0.70 0.70 20060921 0534 B1354112 0.50 0.60 0.60 20060921 1800 B1344502 0.40 0.40 0.40 20060922 0525 B1354531 0.70 0.80 0.80 20060922 1736 B1354541 0.70 0.70 0.70 20060923 0519 B1354101 0.50 0.60 0.60 20060923 1738 B1354576 0.70 0.50 0.70 20060924 0536 B1354095 0.60 0.60 0.60 20060925 0536 B1354098 0.60 0.60 0.60 20060925 1755 B1354100 0.50 0.50 0.50 20060926 0531 B1334691 0.70 0.70 0.70 20060926 1742 B1354108 0.40 0.50 0.50 |
Measurements: | nsasondewnpnC1.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
09/29/2006 | 0500 | 12/31/9999 | 2359 |
Subject: | NSA/SONDE/C1 - Increased precision for alt, dp, pres, rh, tdry |
DataStreams: | nsasondewnpnC1.b1 |
Description: | The output precision of the following variables was increased 20060929: alt changed from 1m to 0.1m dp changed from 0.1degC to 0.01degC pres changed from 0.1 hPa to 0.01 hPa RH changed from 1%RH to 0.01%RH tdry changed from .1degC to 0.01degC Note that the increase in precision does not necessarily imply an increase in accuracy. Users are cautioned to continue to use their best scientific judgement when using these or any other data. |
Measurements: | nsasondewnpnC1.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/07/2006 | 0524 | 10/07/2006 | 0525 |
Subject: | NSA/SONDE/C1 - Incorrect surface values of T and RH |
DataStreams: | nsasondewnpnC1.b1 |
Description: | The radiosonde was launched too quickly after being removed from the ground check set. As a result, the system did not equilibrate with the local ground conditions and the automatically entered surface values are incorrect. |
Measurements: | nsasondewnpnC1.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/28/2006 | 0532 | 10/28/2006 | 0710 |
Subject: | NSA/SONDE/C1 - RH sensor failure |
DataStreams: | nsasondewnpnC1.b1 |
Description: | It appears that one of the two RH sensors on this radiosonde was affected by ice after emerging from a low cold cloud. As a result the reported RH values oscillate by about 10 percent until the alternate heating cycle stops. I suspect the lower value is more close to correct, but can't be absolutely sure. |
Measurements: | nsasondewnpnC1.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
05/27/1992 | 0000 | 05/31/2002 | 2359 |
Subject: | SGP/SONDE - Dry bias in sonde RH |
DataStreams: | sgpsondeB1.00, sgpsondeB1.a0, sgpsondeB1.a1, sgpsondeB4.00, sgpsondeB4.a0, sgpsondeB4.a1, sgpsondeB5.00, sgpsondeB5.a0, sgpsondeB5.a1, sgpsondeB6.00, sgpsondeC1.00, sgpsondeC1.a0, sgpsondeC1.a1, DsgpsondeB1.00, DsgpsondeB1.a0, DsgpsondeB1.a1, DsgpsondeB4.00, DsgpsondeB4.a0, DsgpsondeB4.a1, DsgpsondeB5.00, DsgpsondeB5.a0, DsgpsondeB5.a1, DsgpsondeC1.00, DsgpsondeC1.a0, DsgpsondeC1.a1, sgpsondeptuC1.00, DsgpsondeptuB1.00, DsgpsondeptuB4.00, DsgpsondeptuB5.00, DsgpsondeptuB6.00, DsgpsondeptuC1.00, sgpsondewnpnB1.a0, sgpsondewnpnB1.a1, sgpsondewnpnB4.a0, sgpsondewnpnB4.a1, sgpsondewnpnB5.a0, sgpsondewnpnB5.a1, sgpsondewnpnB6.a0, sgpsondewnpnB6.a1, sgpsondewnpnC1.a0, sgpsondewnpnC1.a1, sgpsondewnprC1.a0, sgpsondewnprC1.a1, sgpsondewrpnB1.00, sgpsondewrpnB1.a0, sgpsondewrpnB1.a1, sgpsondewrpnB4.00, sgpsondewrpnB4.a0, sgpsondewrpnB4.a1, sgpsondewrpnB5.00, sgpsondewrpnB5.a0, sgpsondewrpnB5.a1, sgpsondewrpnB6.00, sgpsondewrpnB6.a0, sgpsondewrpnB6.a1, sgpsondewrpnC1.00, sgpsondewrpnC1.a0, sgpsondewrpnC1.a1, sgpsondewrprB1.00, sgpsondewrprB1.a0, sgpsondewrprB1.a1, sgpsondewrprB4.00, sgpsondewrprB4.a0, sgpsondewrprB4.a1, sgpsondewrprB5.00, sgpsondewrprB5.a0, sgpsondewrprB5.a1, sgpsondewrprC1.00, sgpsondewrprC1.a0, sgpsondewrprC1.a1, DsgpsondeptucalcB1.c1, DsgpsondeptucalcB4.c1, DsgpsondeptucalcB5.c1, DsgpsondeptucalcC1.c1, DsgpsondenogcwrpnB1.c1, DsgpsondenogcwrpnB4.c1, DsgpsondenogcwrpnB5.c1, DsgpsondenogcwrpnC1.c1, DsgpsondenogcptucalcB1.c1, DsgpsondenogcptucalcB4.c1, DsgpsondenogcptucalcB5.c1, DsgpsondenogcptucalcC1.c1 |
Description: | Vaisala has confirmed ARM findings of an apparent dry bias in the relative humidity measured by RS-80H radiosondes. The cause of the dry bias is thought to be contamination of the humidity sensor by volatile organic substances originating from some plastic parts of the radiosonde. The amount of contamination is a function of the time between the date of sonde manufacture and its use. All RS-80H sondes manufactured before week 34 of 1998 will show this bias. After week 34 of 1998 Vaisala changed its packaging to reduce, but not eliminate the contamination problem. Starting with RS-80 radiosonde manufactured in late June 2000 Vaisala enclosed the sensor boom in an inert plastic shield, thereby eliminating the contamination that caused the dry bias. Starting in May 2001 at the SGP, May 2002 at the TWP, and later 2002 at the NSA, ARM has moved to using RS-90 radiosondes. These sondes are not subject to the contaminatino that caused the dry bias. Vaisala is in the process of developing an algorithm that can be used to estimate the correct RH from knowledge of the sonde age. All of the ARM sounding data have sufficient metadata available to apply the correction. Additionally, ARM has funded a Science Team effort (Milosevich) to develop a 'best' correction algorithm for the RS-80 radiosonde humidity data. When completed this algorithm will allow us to reprocess the accumulated RS-80 data and produce a new data platform with what we hope will be more accurate data. |
Measurements: | sgpsondeB4.00:
DsgpsondeB5.00:
sgpsondewrpnC1.00:
sgpsondewnpnC1.a1:
DsgpsondeptuB6.00:
DsgpsondenogcptucalcB1.c1:
sgpsondewrpnB6.a0:
DsgpsondeptuC1.00:
sgpsondewnprC1.a0:
DsgpsondenogcptucalcB5.c1:
DsgpsondeptucalcC1.c1:
sgpsondewnpnB4.a1:
sgpsondeB6.00:
sgpsondewrprB4.00:
DsgpsondeptuB1.00:
DsgpsondenogcptucalcC1.c1:
sgpsondewrpnC1.a1:
sgpsondewrpnB1.a1:
sgpsondewrprC1.00:
sgpsondewrpnB1.a0:
sgpsondewrprB5.a1:
sgpsondeB5.a1:
sgpsondewrprB5.00:
DsgpsondeC1.00:
sgpsondewrprB1.a1:
sgpsondeB1.00:
sgpsondeptuC1.00:
DsgpsondenogcptucalcB4.c1:
DsgpsondeB1.a0:
DsgpsondeC1.a1:
DsgpsondeptucalcB5.c1:
sgpsondewrprB1.00:
sgpsondewrpnC1.a0:
sgpsondewrpnB1.00:
sgpsondeB1.a0:
DsgpsondeC1.a0:
DsgpsondeB4.a1:
DsgpsondeptuB4.00:
sgpsondeB1.a1:
sgpsondewrprB5.a0:
sgpsondeC1.00:
sgpsondewnpnB1.a1:
sgpsondewrpnB6.a1:
sgpsondewrprC1.a0:
sgpsondeC1.a0:
sgpsondewrprC1.a1:
DsgpsondeptuB5.00:
sgpsondewrpnB5.a0:
sgpsondewrprB4.a1:
DsgpsondeB1.a1:
sgpsondeB5.a0:
sgpsondewnpnB6.a0:
DsgpsondeB5.a1:
DsgpsondenogcwrpnB1.c1:
sgpsondewrprB1.a0:
sgpsondewrpnB5.00:
DsgpsondeB4.a0:
DsgpsondenogcwrpnB4.c1:
DsgpsondeB5.a0:
sgpsondewnpnB4.a0:
sgpsondewnprC1.a1:
sgpsondewrpnB5.a1:
sgpsondewnpnB5.a0:
DsgpsondeB4.00:
sgpsondewrpnB6.00:
sgpsondewrprB4.a0:
sgpsondewnpnB1.a0:
sgpsondeB4.a1:
sgpsondeC1.a1:
sgpsondewrpnB4.00:
DsgpsondenogcwrpnB5.c1:
sgpsondewnpnC1.a0:
sgpsondewrpnB4.a0:
DsgpsondeB1.00:
sgpsondeB4.a0:
sgpsondewnpnB6.a1:
sgpsondewrpnB4.a1:
sgpsondewnpnB5.a1:
DsgpsondeptucalcB4.c1:
DsgpsondenogcwrpnC1.c1:
sgpsondeB5.00:
DsgpsondeptucalcB1.c1:
|