DQR ID | Subject | Data Streams Affected |
---|---|---|
D060921.3 | SGP/EBBR/E12 - Net Radiation, and Sensible and Latent Heat Fluxes Incorrect | sgp5ebbrE12.b1, sgp15ebbrE12.b1, sgp30ebbrE12.b1 |
Start Date | Start Time | End Date | End Time |
---|---|---|---|
08/21/2006 | 1200 | 08/29/2006 | 1630 |
Subject: | SGP/EBBR/E12 - Net Radiation, and Sensible and Latent Heat Fluxes Incorrect |
DataStreams: | sgp5ebbrE12.b1, sgp15ebbrE12.b1, sgp30ebbrE12.b1 |
Description: | Rain entered into the net radiometer through a broken top dome. Most of the net radiation values during the period are much too large, thus sensible and latent fluxes are also too large. |
Measurements: | sgp15ebbrE12.b1:
sgp5ebbrE12.b1:
sgp30ebbrE12.b1:
|