Data Quality Reports for Session: 104944 User: wlj Completed: 03/23/2007


TABLE OF CONTENTS

DQR IDSubjectData Streams Affected
D021211.12NSA/GNDRAD/C1 - Noisy PIR Datansagndrad60sC1.a1, nsagndrad60sC1.b1
D021211.2NSA/GNDRAD/C1 - IRT instrument maintenancensagndrad60sC1.a1, nsagndrad60sC1.b1
D021211.6NSA/GNDRAD/C1 - IRT data noisynsagndrad60sC1.a1, nsagndrad60sC1.b1
D021212.1NSA/GNDRAD/C1 - Instrument Maintenancensagndrad60sC1.a1, nsagndrad60sC1.b1
D021212.10NSA/GNDRAD/C1 - Unreasonable PSP Datansagndrad60sC1.a1, nsagndrad60sC1.b1
D021212.2NSA/GNDRAD/C1 - PSP erroneously replaced by B&Wnsagndrad60sC1.a1, nsagndrad60sC1.b1
D021212.3NSA/GNDRAD/C1 - Instrument maintenancensagndrad60sC1.a1, nsagndrad60sC1.b1
D021212.4NSA/GNDRAD/C1 - Bad calibrations appliednsagndrad60sC1.a1, nsagndrad60sC1.b1
D021212.6NSA/GNDRAD/C1 - Unexplained decrease in PSP and NET data valuesnsagndrad60sC1.a1, nsagndrad60sC1.b1
D021212.7NSA/GNDRAD/C1 - Data corrupted by brief spikensagndrad60sC1.a1, nsagndrad60sC1.b1
D021212.8NSA/GNDRAD/C1 - Rad instruments shaded by shelternsagndrad60sC1.a1, nsagndrad60sC1.b1
D021212.9NSA/GNDRAD/C1 - PSP Data corrupted by brief spikensagndrad60sC1.a1, nsagndrad60sC1.b1
D030301.1NSA/GNDRAD/C1 - No power to IRTnsagndrad60sC1.a1, nsagndrad60sC1.b1
D031216.1NSA/GNDRAD/C1 - IRT cable failurensagndrad60sC1.b1
D031216.2NSA/GNDRAD/C1 - IRT returned to vendornsagndrad60sC1.b1


DQRID : D021211.12
Start DateStart TimeEnd DateEnd Time
03/01/1999000012/31/20002359
Subject:
NSA/GNDRAD/C1 - Noisy PIR Data
DataStreams:nsagndrad60sC1.a1, nsagndrad60sC1.b1
Description:
During the period referenced, the ground PIR was noisy in  
              comparison to the the sky PIR data.  (Note U021211.1 documents
              same problem for 9/1/98-2/28/99)

              The noise problem continued after the GNDRAD data logger was 
              replaced in late September. Particularly strong examples of the 
              noise can be seen in data from 11/10 - 11/19/99. The peak to 
              peak noise reaches 12 W/m2.
Measurements:nsagndrad60sC1.b1:
  • PIR1 unshaded minimum(pir1_min)
  • PIR1 unshaded maximum(pir1_max)
  • PIR1 unshaded mean(pir1_mean)
  • PIR1 unshaded standard deviation(pir1_sd)

nsagndrad60sC1.a1:
  • PIR1 unshaded standard deviation(pir1_sd)
  • PIR1 unshaded mean(pir1_mean)
  • PIR1 unshaded maximum(pir1_max)
  • PIR1 unshaded minimum(pir1_min)


Back To Table of Contents

DQRID : D021211.2
Start DateStart TimeEnd DateEnd Time
09/15/1999172009/15/19992000
Subject:
NSA/GNDRAD/C1 - IRT instrument maintenance
DataStreams:nsagndrad60sC1.a1, nsagndrad60sC1.b1
Description:
IRT offline while instrument cable was being rebuilt.  Data are bad.
Measurements:nsagndrad60sC1.b1:
  • IRT1 minimum(irt1_min)
  • IRT1 maximum(irt1_max)
  • IRT1 standard deviation(irt1_sd)
  • IRT1 mean(irt1_mean)

nsagndrad60sC1.a1:
  • IRT1 standard deviation(irt1_sd)
  • IRT1 mean(irt1_mean)
  • IRT1 maximum(irt1_max)
  • IRT1 minimum(irt1_min)


Back To Table of Contents

DQRID : D021211.6
Start DateStart TimeEnd DateEnd Time
12/10/1999000012/29/20001859
Subject:
NSA/GNDRAD/C1 - IRT data noisy
DataStreams:nsagndrad60sC1.a1, nsagndrad60sC1.b1
Description:
After re-installation of the IRT on 12/10/99, the data are noisy. Source of the noise is 
believed to be the heater connected directly to the IRT.  Instrument was taken offline on 
12/30/1999 and shipped back to PNNL for repair/testing.
Measurements:nsagndrad60sC1.b1:
  • IRT1 minimum(irt1_min)
  • IRT1 maximum(irt1_max)
  • IRT1 standard deviation(irt1_sd)
  • IRT1 mean(irt1_mean)

nsagndrad60sC1.a1:
  • IRT1 standard deviation(irt1_sd)
  • IRT1 mean(irt1_mean)
  • IRT1 maximum(irt1_max)
  • IRT1 minimum(irt1_min)


Back To Table of Contents

DQRID : D021212.1
Start DateStart TimeEnd DateEnd Time
06/13/2001210006/13/20012200
Subject:
NSA/GNDRAD/C1 - Instrument Maintenance
DataStreams:nsagndrad60sC1.a1, nsagndrad60sC1.b1
Description:
Tip tower was lowered for instrument maintenance.  Data taken 
              during this period are corrupt.
Measurements:nsagndrad60sC1.b1:
  • PSP1 unshaded standard deviation(psp1_sd)
  • PSP1 unshaded minimum(psp1_min)
  • PSP1 unshaded mean(psp1_mean)
  • PSP1 unshaded maximum(psp1_max)

nsagndrad60sC1.a1:
  • PSP1 unshaded maximum(psp1_max)
  • PSP1 unshaded mean(psp1_mean)
  • PSP1 unshaded minimum(psp1_min)
  • PSP1 unshaded standard deviation(psp1_sd)


Back To Table of Contents

DQRID : D021212.10
Start DateStart TimeEnd DateEnd Time
03/03/1999120003/03/19991515
Subject:
NSA/GNDRAD/C1 - Unreasonable PSP Data
DataStreams:nsagndrad60sC1.a1, nsagndrad60sC1.b1
Description:
During the darkness in the middle of this night, the PSP had a
              signal of 15 W/m2 over a three hour long period.  Cause unknown.
Measurements:nsagndrad60sC1.b1:
  • PSP1 unshaded standard deviation(psp1_sd)
  • PSP1 unshaded minimum(psp1_min)
  • PSP1 unshaded mean(psp1_mean)
  • PSP1 unshaded maximum(psp1_max)

nsagndrad60sC1.a1:
  • PSP1 unshaded maximum(psp1_max)
  • PSP1 unshaded mean(psp1_mean)
  • PSP1 unshaded minimum(psp1_min)
  • PSP1 unshaded standard deviation(psp1_sd)


Back To Table of Contents

DQRID : D021212.2
Start DateStart TimeEnd DateEnd Time
06/13/2001230006/21/20011800
Subject:
NSA/GNDRAD/C1 - PSP erroneously replaced by B&W
DataStreams:nsagndrad60sC1.a1, nsagndrad60sC1.b1
Description:
The PSP was erroneously replaced with a B&W on 6/13 and then 
              changed back to the PSP on 6/21. Data should still be good since
              appropriate calibration factors were applied.
Measurements:nsagndrad60sC1.b1:
  • PSP1 unshaded standard deviation(psp1_sd)
  • PSP1 unshaded minimum(psp1_min)
  • PSP1 unshaded mean(psp1_mean)
  • PSP1 unshaded maximum(psp1_max)

nsagndrad60sC1.a1:
  • PSP1 unshaded maximum(psp1_max)
  • PSP1 unshaded mean(psp1_mean)
  • PSP1 unshaded minimum(psp1_min)
  • PSP1 unshaded standard deviation(psp1_sd)


Back To Table of Contents

DQRID : D021212.3
Start DateStart TimeEnd DateEnd Time
06/21/2001180006/21/20011830
Subject:
NSA/GNDRAD/C1 - Instrument maintenance
DataStreams:nsagndrad60sC1.a1, nsagndrad60sC1.b1
Description:
The tip tower was lowered for instrument maintenance.  Data
              recorded are garbage.
Measurements:nsagndrad60sC1.b1:
  • PSP1 unshaded standard deviation(psp1_sd)
  • PSP1 unshaded minimum(psp1_min)
  • PSP1 unshaded mean(psp1_mean)
  • PSP1 unshaded maximum(psp1_max)

nsagndrad60sC1.a1:
  • PSP1 unshaded maximum(psp1_max)
  • PSP1 unshaded mean(psp1_mean)
  • PSP1 unshaded minimum(psp1_min)
  • PSP1 unshaded standard deviation(psp1_sd)


Back To Table of Contents

DQRID : D021212.4
Start DateStart TimeEnd DateEnd Time
11/08/2001010011/09/20010300
Subject:
NSA/GNDRAD/C1 - Bad calibrations applied
DataStreams:nsagndrad60sC1.a1, nsagndrad60sC1.b1
Description:
Bad data due to erroneous calibration constant in configuration 
              file
Measurements:nsagndrad60sC1.b1:
  • PSP1 unshaded standard deviation(psp1_sd)
  • PIR1 unshaded mean(pir1_mean)
  • PIR1 unshaded standard deviation(pir1_sd)
  • PSP1 unshaded mean(psp1_mean)
  • PIR1 unshaded minimum(pir1_min)
  • PIR1 unshaded maximum(pir1_max)
  • PSP1 unshaded minimum(psp1_min)
  • PSP1 unshaded maximum(psp1_max)

nsagndrad60sC1.a1:
  • PSP1 unshaded maximum(psp1_max)
  • PIR1 unshaded standard deviation(pir1_sd)
  • PIR1 unshaded maximum(pir1_max)
  • PIR1 unshaded mean(pir1_mean)
  • PIR1 unshaded minimum(pir1_min)
  • PSP1 unshaded mean(psp1_mean)
  • PSP1 unshaded minimum(psp1_min)
  • PSP1 unshaded standard deviation(psp1_sd)


Back To Table of Contents

DQRID : D021212.6
Start DateStart TimeEnd DateEnd Time
04/27/1999233004/27/19992335
04/28/1999192004/28/19991930
Subject:
NSA/GNDRAD/C1 - Unexplained decrease in PSP and NET data values
DataStreams:nsagndrad60sC1.a1, nsagndrad60sC1.b1
Description:
100 W/m2 dip in the PSP data; NET data also affected. Possibly 
              due to operators working around the instruments.
Measurements:nsagndrad60sC1.b1:
  • NET mean(net_mean)
  • PSP1 unshaded standard deviation(psp1_sd)
  • NET standard deviation(net_sd)
  • Net Radiation(net)
  • PSP1 unshaded mean(psp1_mean)
  • Net Radiation, Standard Deviation(net_std)
  • Net Radiation, Minima(net_min)
  • PSP1 unshaded minimum(psp1_min)
  • Net Radiation, Maxima(net_max)
  • PSP1 unshaded maximum(psp1_max)

nsagndrad60sC1.a1:
  • PSP1 unshaded maximum(psp1_max)
  • NET mean(net_mean)
  • Net Radiation, Minima(net_min)
  • Net Radiation(net)
  • NET standard deviation(net_sd)
  • Net Radiation, Standard Deviation(net_std)
  • PSP1 unshaded mean(psp1_mean)
  • PSP1 unshaded minimum(psp1_min)
  • Net Radiation, Maxima(net_max)
  • PSP1 unshaded standard deviation(psp1_sd)


Back To Table of Contents

DQRID : D021212.7
Start DateStart TimeEnd DateEnd Time
03/13/1999194503/13/19991955
Subject:
NSA/GNDRAD/C1 - Data corrupted by brief spike
DataStreams:nsagndrad60sC1.a1, nsagndrad60sC1.b1
Description:
There is a unreasonable spike at this time. Simultaneous spikes on the NET, the PSP, and 
the PIR. Cause unknown, but most likely related to data logger.
Measurements:nsagndrad60sC1.b1:
  • Net Radiation(net)
  • PSP1 unshaded mean(psp1_mean)
  • Net Radiation, Standard Deviation(net_std)
  • Net Radiation, Maxima(net_max)
  • PSP1 unshaded maximum(psp1_max)
  • NET mean(net_mean)
  • PSP1 unshaded standard deviation(psp1_sd)
  • NET standard deviation(net_sd)
  • PIR1 unshaded mean(pir1_mean)
  • PIR1 unshaded standard deviation(pir1_sd)
  • PIR1 unshaded minimum(pir1_min)
  • Net Radiation, Minima(net_min)
  • PIR1 unshaded maximum(pir1_max)
  • PSP1 unshaded minimum(psp1_min)

nsagndrad60sC1.a1:
  • PSP1 unshaded maximum(psp1_max)
  • PIR1 unshaded standard deviation(pir1_sd)
  • PIR1 unshaded maximum(pir1_max)
  • Net Radiation, Minima(net_min)
  • PIR1 unshaded minimum(pir1_min)
  • NET standard deviation(net_sd)
  • Net Radiation, Maxima(net_max)
  • NET mean(net_mean)
  • PIR1 unshaded mean(pir1_mean)
  • Net Radiation(net)
  • Net Radiation, Standard Deviation(net_std)
  • PSP1 unshaded mean(psp1_mean)
  • PSP1 unshaded minimum(psp1_min)
  • PSP1 unshaded standard deviation(psp1_sd)


Back To Table of Contents

DQRID : D021212.8
Start DateStart TimeEnd DateEnd Time
03/08/1999000009/30/19992359
Subject:
NSA/GNDRAD/C1 - Rad instruments shaded by shelter
DataStreams:nsagndrad60sC1.a1, nsagndrad60sC1.b1
Description:
Each day around 02:00 - 03:30 GMT there is a unexpected decrease 
              for the PSP irradiance measurement due to a shading problem 
              associated with the swing set location relative to the instrument 
              shelter.  The GNDRAD NET and MFR instrument data also reflects 
              this problem.  Problem was resolved when the GNDRAD instruments 
              were moved to the 10 meter tip tower.
Measurements:nsagndrad60sC1.b1:
  • Net Radiation(net)
  • PSP1 unshaded mean(psp1_mean)
  • Net Radiation, Standard Deviation(net_std)
  • Net Radiation, Maxima(net_max)
  • PSP1 unshaded maximum(psp1_max)
  • NET mean(net_mean)
  • PSP1 unshaded standard deviation(psp1_sd)
  • NET standard deviation(net_sd)
  • PIR1 unshaded mean(pir1_mean)
  • PIR1 unshaded standard deviation(pir1_sd)
  • PIR1 unshaded minimum(pir1_min)
  • Net Radiation, Minima(net_min)
  • PIR1 unshaded maximum(pir1_max)
  • PSP1 unshaded minimum(psp1_min)

nsagndrad60sC1.a1:
  • PSP1 unshaded maximum(psp1_max)
  • PIR1 unshaded standard deviation(pir1_sd)
  • PIR1 unshaded maximum(pir1_max)
  • Net Radiation, Minima(net_min)
  • PIR1 unshaded minimum(pir1_min)
  • NET standard deviation(net_sd)
  • Net Radiation, Maxima(net_max)
  • NET mean(net_mean)
  • PIR1 unshaded mean(pir1_mean)
  • Net Radiation(net)
  • Net Radiation, Standard Deviation(net_std)
  • PSP1 unshaded mean(psp1_mean)
  • PSP1 unshaded minimum(psp1_min)
  • PSP1 unshaded standard deviation(psp1_sd)


Back To Table of Contents

DQRID : D021212.9
Start DateStart TimeEnd DateEnd Time
11/07/2001210011/07/20012105
Subject:
NSA/GNDRAD/C1 - PSP Data corrupted by brief spike
DataStreams:nsagndrad60sC1.a1, nsagndrad60sC1.b1
Description:
Large unreasonable narrow spike in PSP data; cause not known.
Measurements:nsagndrad60sC1.b1:
  • PSP1 unshaded standard deviation(psp1_sd)
  • PSP1 unshaded minimum(psp1_min)
  • PSP1 unshaded mean(psp1_mean)
  • PSP1 unshaded maximum(psp1_max)

nsagndrad60sC1.a1:
  • PSP1 unshaded maximum(psp1_max)
  • PSP1 unshaded mean(psp1_mean)
  • PSP1 unshaded minimum(psp1_min)
  • PSP1 unshaded standard deviation(psp1_sd)


Back To Table of Contents

DQRID : D030301.1
Start DateStart TimeEnd DateEnd Time
09/24/2002172511/16/20020003
Subject:
NSA/GNDRAD/C1 - No power to IRT
DataStreams:nsagndrad60sC1.a1, nsagndrad60sC1.b1
Description:
The data logger failed to supply power to the IRT.
Measurements:nsagndrad60sC1.b1:
  • Surface Infra-Red Temperature Maxima(sfc_ir_temp_max)
  • Surface Infra-Red Temperature Minima(sfc_ir_temp_min)
  • Effective Surface (Skin) Temperature(sfc_ir_temp)
  • Surface Infra-Red Temperature, Standard Deviation(sfc_ir_temp_std)

nsagndrad60sC1.a1:
  • Surface Infra-Red Temperature Maxima(sfc_ir_temp_max)
  • Effective Surface (Skin) Temperature(sfc_ir_temp)
  • Surface Infra-Red Temperature Minima(sfc_ir_temp_min)
  • Surface Infra-Red Temperature, Standard Deviation(sfc_ir_temp_std)


Back To Table of Contents

DQRID : D031216.1
Start DateStart TimeEnd DateEnd Time
05/27/2003140009/11/20031906
Subject:
NSA/GNDRAD/C1 - IRT cable failure
DataStreams:nsagndrad60sC1.b1
Description:
The IRT signal became very noisy and the problem was traced to the cable (after the 
instrument was returned to the vendor for diagnosis). The problem started occurring when ice 
surrounding the cable began to melt. The cable was repaired and the instrument reinstalled.
Measurements:nsagndrad60sC1.b1:
  • Surface Infra-Red Temperature Maxima(sfc_ir_temp_max)
  • Surface Infra-Red Temperature Minima(sfc_ir_temp_min)
  • Effective Surface (Skin) Temperature(sfc_ir_temp)
  • Surface Infra-Red Temperature, Standard Deviation(sfc_ir_temp_std)


Back To Table of Contents

DQRID : D031216.2
Start DateStart TimeEnd DateEnd Time
09/11/2003190610/15/20030015
Subject:
NSA/GNDRAD/C1 - IRT returned to vendor
DataStreams:nsagndrad60sC1.b1
Description:
The IRT was returned to the vendor for diagnosis. It was found to be operating as expected 
and the signal noise problem was traced to the cable. The cable was repaired and the 
instrument reinstalled.
Measurements:nsagndrad60sC1.b1:
  • Surface Infra-Red Temperature Maxima(sfc_ir_temp_max)
  • Surface Infra-Red Temperature Minima(sfc_ir_temp_min)
  • Effective Surface (Skin) Temperature(sfc_ir_temp)
  • Surface Infra-Red Temperature, Standard Deviation(sfc_ir_temp_std)


Back To Table of Contents



END OF DATA