DQR ID | Subject | Data Streams Affected |
---|---|---|
D011127.23 | SGP EBBR E7 - E7 EBBR Data Incorrect During 6 Month Checks | sgp5ebbrE7.a1, sgp15ebbrE7.a1, sgp15ebbrE7.b1, sgp30ebbrE7.a1, sgp30ebbrE7.b1 |
D011129.6 | SGP EBBR E7 - E7 EBBR AEM Position Caused Incorrect Data | sgp5ebbrE7.a1, sgp15ebbrE7.a1, sgp15ebbrE7.b1, sgp30ebbrE7.a1, sgp30ebbrE7.b1 |
D011129.7 | SGP EBBR E7 - E7 EBBR All Data Incorrect | sgp5ebbrE7.a1, sgp15ebbrE7.a1, sgp15ebbrE7.b1, sgp30ebbrE7.a1, sgp30ebbrE7.b1 |
D011129.8 | SGP EBBR E7 - E7 EBBR Data Incorrect After Recalibration | sgp15ebbrE7.a1, sgp15ebbrE7.b1, sgp30ebbrE7.a1, sgp30ebbrE7.b1 |
D011129.9 | SGP EBBR E7 - E7 EBBR Data Incorrect After Missing Data Period | sgp15ebbrE7.a1, sgp15ebbrE7.b1, sgp30ebbrE7.a1, sgp30ebbrE7.b1 |
D020716.27 | SGP/EBBR/E7 - AEM Hung | sgp5ebbrE7.a1, sgp15ebbrE7.a1, sgp15ebbrE7.b1, sgp30ebbrE7.a1, sgp30ebbrE7.b1 |
D020716.28 | SGP/EBBR/E7 - Wind Speed Incorrect | sgp5ebbrE7.a1, sgp15ebbrE7.a1, sgp15ebbrE7.b1, sgp30ebbrE7.a1, sgp30ebbrE7.b1 |
D020716.8 | SGP/EBBR/E7 - 6 Month Checks | sgp5ebbrE7.a1, sgp15ebbrE7.a1, sgp15ebbrE7.b1, sgp30ebbrE7.a1, sgp30ebbrE7.b1 |
D020910.19 | SGP/SMOS/E7 - 1 minute Data Values Incorrect | sgp1smosE7.a1, sgp1smosE7.b1 |
D020911.4 | SGP/SMOS/E7 - Barometric Pressure Incorrect | sgp1smosE7.a1, sgp1smosE7.b1 |
D021113.1 | SGP/EBBR - Incorrect Units for Soil Heat Capacity (cs1, cs2, cs3, cs4, cs5) in 30EBBR Header | sgp30ebbrE2.b1, sgp30ebbrE4.b1, sgp30ebbrE7.b1, sgp30ebbrE8.b1, sgp30ebbrE9.b1, sgp30ebbrE12.b1, sgp30ebbrE13.b1, sgp30ebbrE15.b1, sgp30ebbrE18.b1, sgp30ebbrE19.b1, sgp30ebbrE20.b1, sgp30ebbrE22.b1, sgp30ebbrE26.b1 |
D030113.1 | SGP/EBBR/E7 - Wind speed incorrect | sgp5ebbrE7.a1, sgp15ebbrE7.a1, sgp15ebbrE7.b1, sgp30ebbrE7.a1, sgp30ebbrE7.b1 |
D030113.3 | SGP/EBBR/E7 - CES data incorrect | sgp30ebbrE7.a1, sgp30ebbrE7.b1 |
D030113.6 | SGP/EBBR/E7 - REPROCESS: Soil Heat Flow #5 too low | sgp30ebbrE7.a1, sgp30ebbrE7.b1 |
D030113.7 | SGP/EBBR/E7 - AEM Problems | sgp5ebbrE7.a1, sgp15ebbrE7.a1, sgp15ebbrE7.b1, sgp30ebbrE7.a1, sgp30ebbrE7.b1 |
D030114.2 | SGP/EBBR/E7 - Data Reported as Zero following Logger Replacement | sgp5ebbrE7.a1, sgp15ebbrE7.a1, sgp15ebbrE7.b1, sgp30ebbrE7.a1, sgp30ebbrE7.b1 |
D030620.1 | SGP/EBBR/E7 - Soil Heat Flow #5 Incorrect | sgp15ebbrE7.a1, sgp15ebbrE7.b1, sgp30ebbrE7.a1, sgp30ebbrE7.b1 |
D030712.13 | SGP/EBBR/E7 - 6 Month Checks | sgp5ebbrE7.a1, sgp15ebbrE7.a1, sgp15ebbrE7.b1, sgp30ebbrE7.a1, sgp30ebbrE7.b1 |
D030729.3 | SGP/EBBR/E7 - AEM Malfunction, Some Data Incorrect | sgp5ebbrE7.a1, sgp15ebbrE7.a1, sgp15ebbrE7.b1, sgp30ebbrE7.a1, sgp30ebbrE7.b1 |
D030919.1 | SGP/EBBR/E7 - Data all zero | sgp5ebbrE7.a1, sgp15ebbrE7.a1, sgp15ebbrE7.b1, sgp30ebbrE7.a1, sgp30ebbrE7.b1 |
D030919.2 | SGP/EBBR/E7 - Energy Storage Incorrect, Fluxes Incorrect | sgp30ebbrE7.a1, sgp30ebbrE7.b1 |
D030919.3 | SGP/EBBR/E7 - Water in Net Radiometer Domes; Surface Fluxes are Incorrect | sgp5ebbrE7.a1, sgp15ebbrE7.a1, sgp15ebbrE7.b1, sgp30ebbrE7.a1, sgp30ebbrE7.b1 |
D031211.6 | SGP/EBBR/E7 - Pressure Sensor Data Incorrect | sgp5ebbrE7.a1, sgp15ebbrE7.b1, sgp30ebbrE7.b1 |
D040317.6 | SGP/SMOS/E7 - 6-month Calibration Checks | sgp1smosE7.a1, sgp1smosE7.b1, sgp30smosE7.a1, sgp30smosE7.b1, sgp1440smosE7.a1 |
D040317.7 | SGP/SMOS/E7 - 6-month Calibration Checks | sgp1smosE7.b1, sgp30smosE7.b1, sgp1440smosE7.b1 |
D040625.1 | SGP/SWATS/E7 - Incorrect Soil Temp and Moisture Data | sgpswatsE7.00, sgpswatsE7.b1 |
D040625.2 | SGP/SWATS/E7 - Incorrect Soil Moisture Data | sgpswatsE7.00, sgpswatsE7.b1 |
D040714.1 | SGP/SWATS/E7 - Missing Data | sgpswatsE7.00, sgpswatsE7.b1 |
D040715.2 | SGP/SMOS/E7 - datalogger down due to power outage | sgp1smosE7.b1, sgp30smosE7.b1, sgp1440smosE7.b1 |
D040813.8 | SGP/EBBR/E7 - Pressure Too High | sgp5ebbrE7.b1, sgp15ebbrE7.b1, sgp30ebbrE7.b1 |
D041005.3 | SGP/EBBR/E7 - Data Missing | sgp5ebbrE7.b1, sgp15ebbrE7.b1, sgp30ebbrE7.b1 |
D050422.5 | SGP/SMOS/E7 - Reprocess: Wind direction offset | sgp1smosE7.b1, sgp30smosE7.b1 |
D050719.6 | SGP/EBBR/E7 - Improved EBBR CR10 Program | sgp30ebbrE7.b1 |
D051024.1 | SGP/EBBR/E7 - Data Missing | sgp5ebbrE7.b1, sgp15ebbrE7.b1, sgp30ebbrE7.b1 |
D051106.3 | SGP/EBBR/E7 - Net Radiation Incorrect; Sensible and Latent Heat Fluxes Incorrect | sgp5ebbrE7.b1, sgp15ebbrE7.b1, sgp30ebbrE7.b1 |
D051112.4 | SGP/EBBR/E7 - metadata corrections | sgp5ebbrE7.b1, sgp15ebbrE7.b1, sgp30ebbrE7.b1 |
D060501.5 | SGP/EBBR/E7 - Missing Data | sgp5ebbrE7.b1, sgp15ebbrE7.b1, sgp30ebbrE7.b1 |
D060921.2 | SGP/EBBR/E7 - Data Missing | sgp5ebbrE7.b1, sgp15ebbrE7.b1, sgp30ebbrE7.b1 |
Start Date | Start Time | End Date | End Time |
---|---|---|---|
05/08/2001 | 1800 | 05/08/2001 | 1901 |
11/25/2001 | 1435 | 11/25/2001 | 1601 |
Subject: | SGP EBBR E7 - E7 EBBR Data Incorrect During 6 Month Checks |
DataStreams: | sgp5ebbrE7.a1, sgp15ebbrE7.a1, sgp15ebbrE7.b1, sgp30ebbrE7.a1, sgp30ebbrE7.b1 |
Description: | The data was incorrect during the 6 month checks. |
Measurements: | sgp5ebbrE7.a1:
sgp30ebbrE7.a1:
sgp15ebbrE7.a1:
sgp15ebbrE7.b1:
sgp30ebbrE7.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
04/10/2001 | 1945 | 04/10/2001 | 2031 |
Subject: | SGP EBBR E7 - E7 EBBR AEM Position Caused Incorrect Data |
DataStreams: | sgp5ebbrE7.a1, sgp15ebbrE7.a1, sgp15ebbrE7.b1, sgp30ebbrE7.a1, sgp30ebbrE7.b1 |
Description: | The AEM stuck in one position, causing the indicated measurements and calculated quantities to be incorrect. |
Measurements: | sgp5ebbrE7.a1:
sgp15ebbrE7.a1:
sgp30ebbrE7.a1:
sgp15ebbrE7.b1:
sgp30ebbrE7.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
05/07/2001 | 1900 | 05/07/2001 | 1901 |
Subject: | SGP EBBR E7 - E7 EBBR All Data Incorrect |
DataStreams: | sgp5ebbrE7.a1, sgp15ebbrE7.a1, sgp15ebbrE7.b1, sgp30ebbrE7.a1, sgp30ebbrE7.b1 |
Description: | The data was incorrect immediately after the re-calibrated system was installed and put into service. |
Measurements: | sgp5ebbrE7.a1:
sgp30ebbrE7.a1:
sgp15ebbrE7.a1:
sgp15ebbrE7.b1:
sgp30ebbrE7.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
05/07/2001 | 1930 | 05/07/2001 | 1931 |
Subject: | SGP EBBR E7 - E7 EBBR Data Incorrect After Recalibration |
DataStreams: | sgp15ebbrE7.a1, sgp15ebbrE7.b1, sgp30ebbrE7.a1, sgp30ebbrE7.b1 |
Description: | Soil temperature measurements and the half hour average were incorrect the half hour after starting the recalibrated system, causing other measurements and calculated quantities to be incorrect. |
Measurements: | sgp15ebbrE7.a1:
sgp30ebbrE7.a1:
sgp15ebbrE7.b1:
sgp30ebbrE7.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
08/28/2001 | 1900 | 08/28/2001 | 1901 |
Subject: | SGP EBBR E7 - E7 EBBR Data Incorrect After Missing Data Period |
DataStreams: | sgp15ebbrE7.a1, sgp15ebbrE7.b1, sgp30ebbrE7.a1, sgp30ebbrE7.b1 |
Description: | Soil temperature measurements and the half hour average were incorrect the half hour after a missing data period, causing other measurements and calculated quantities to be incorrect. |
Measurements: | sgp15ebbrE7.a1:
sgp30ebbrE7.a1:
sgp15ebbrE7.b1:
sgp30ebbrE7.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
04/14/2002 | 2200 | 04/23/2002 | 1531 |
05/20/2002 | 1200 | 06/06/2002 | 1501 |
Subject: | SGP/EBBR/E7 - AEM Hung |
DataStreams: | sgp5ebbrE7.a1, sgp15ebbrE7.a1, sgp15ebbrE7.b1, sgp30ebbrE7.a1, sgp30ebbrE7.b1 |
Description: | The indicated measurements were incorrect because the automatic exchange mechanism hung in one position. |
Measurements: | sgp5ebbrE7.a1:
sgp15ebbrE7.a1:
sgp30ebbrE7.a1:
sgp15ebbrE7.b1:
sgp30ebbrE7.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
05/20/2002 | 1200 | 05/21/2002 | 1601 |
Subject: | SGP/EBBR/E7 - Wind Speed Incorrect |
DataStreams: | sgp5ebbrE7.a1, sgp15ebbrE7.a1, sgp15ebbrE7.b1, sgp30ebbrE7.a1, sgp30ebbrE7.b1 |
Description: | The wind speed and resultant wind speed are incorrect for the indicated times because a cup had broken off of the cup anemometer. |
Measurements: | sgp5ebbrE7.a1:
sgp15ebbrE7.a1:
sgp30ebbrE7.a1:
sgp30ebbrE7.b1:
sgp15ebbrE7.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
05/07/2002 | 1645 | 05/07/2002 | 1716 |
Subject: | SGP/EBBR/E7 - 6 Month Checks |
DataStreams: | sgp5ebbrE7.a1, sgp15ebbrE7.a1, sgp15ebbrE7.b1, sgp30ebbrE7.a1, sgp30ebbrE7.b1 |
Description: | The indicated measurements were incorrect during the 6 month checks. |
Measurements: | sgp5ebbrE7.a1:
sgp15ebbrE7.a1:
sgp30ebbrE7.a1:
sgp15ebbrE7.b1:
sgp30ebbrE7.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
06/06/2002 | 1422 | 06/06/2002 | 1438 |
Subject: | SGP/SMOS/E7 - 1 minute Data Values Incorrect |
DataStreams: | sgp1smosE7.a1, sgp1smosE7.b1 |
Description: | Data values incorrect due to tower being lowered for T/RH probe replacement. |
Measurements: | sgp1smosE7.a1:
sgp1smosE7.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
06/13/2002 | 2002 | 06/13/2002 | 2003 |
Subject: | SGP/SMOS/E7 - Barometric Pressure Incorrect |
DataStreams: | sgp1smosE7.a1, sgp1smosE7.b1 |
Description: | The barometric pressure readings were reported as 0.00, reason unknown. |
Measurements: | sgp1smosE7.a1:
sgp1smosE7.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
04/01/2001 | 0000 | 06/18/2003 | 2359 |
Subject: | SGP/EBBR - Incorrect Units for Soil Heat Capacity (cs1, cs2, cs3, cs4, cs5) in 30EBBR |
DataStreams: | sgp30ebbrE2.b1, sgp30ebbrE4.b1, sgp30ebbrE7.b1, sgp30ebbrE8.b1, sgp30ebbrE9.b1, sgp30ebbrE12.b1, sgp30ebbrE13.b1, sgp30ebbrE15.b1, sgp30ebbrE18.b1, sgp30ebbrE19.b1, sgp30ebbrE20.b1, sgp30ebbrE22.b1, sgp30ebbrE26.b1 |
Description: | The units for Soil Heat Capacity (cs1, cs2, cs3, cs4, cs5) in the EBBR 30 minute netcdf header have been incorrect from the beginning of processing the data into netcdf files. The correct units are MJ/m^3/C. This does not affect the data quality. |
Measurements: | sgp30ebbrE8.b1:
sgp30ebbrE4.b1:
sgp30ebbrE9.b1:
sgp30ebbrE18.b1:
sgp30ebbrE26.b1:
sgp30ebbrE13.b1:
sgp30ebbrE7.b1:
sgp30ebbrE12.b1:
sgp30ebbrE19.b1:
sgp30ebbrE2.b1:
sgp30ebbrE22.b1:
sgp30ebbrE20.b1:
sgp30ebbrE15.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
07/11/2002 | 2100 | 07/18/2002 | 1700 |
Subject: | SGP/EBBR/E7 - Wind speed incorrect |
DataStreams: | sgp5ebbrE7.a1, sgp15ebbrE7.a1, sgp15ebbrE7.b1, sgp30ebbrE7.a1, sgp30ebbrE7.b1 |
Description: | A wind speed sensor electronics problem limited the measurement to the sensor offset. This data was incorrect. |
Measurements: | sgp5ebbrE7.a1:
sgp15ebbrE7.a1:
sgp30ebbrE7.a1:
sgp30ebbrE7.b1:
sgp15ebbrE7.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
07/30/2002 | 1900 | 07/30/2002 | 1901 |
Subject: | SGP/EBBR/E7 - CES data incorrect |
DataStreams: | sgp30ebbrE7.a1, sgp30ebbrE7.b1 |
Description: | After a missing half hour, the soil temperature at the beginning of the half hour cannot be used to determine the soil energy storage term. Therefore the change of energy calculation blows up. The indicated measurements are therefore incorrect. |
Measurements: | sgp30ebbrE7.a1:
sgp30ebbrE7.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
09/22/2002 | 1630 | 12/03/2002 | 1830 |
Subject: | SGP/EBBR/E7 - REPROCESS: Soil Heat Flow #5 too low |
DataStreams: | sgp30ebbrE7.a1, sgp30ebbrE7.b1 |
Description: | Soil Heat Flow #5 was sometimes 2X the other soil heat flow measurements when heat flows were negative. This does not usually greatly affect h and e, therefore the data color has been set to yellow. |
Measurements: | sgp30ebbrE7.a1:
sgp30ebbrE7.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
07/10/2002 | 0800 | 07/16/2002 | 1900 |
07/22/2002 | 1630 | 07/30/2002 | 1630 |
08/24/2002 | 0230 | 08/27/2002 | 1800 |
Subject: | SGP/EBBR/E7 - AEM Problems |
DataStreams: | sgp5ebbrE7.a1, sgp15ebbrE7.a1, sgp15ebbrE7.b1, sgp30ebbrE7.a1, sgp30ebbrE7.b1 |
Description: | The AEM (Automatic Exchange Mechanism) hung in a non-home position for a few lengthy periods, during which the indicated measurements are incorrect. |
Measurements: | sgp5ebbrE7.a1:
sgp15ebbrE7.a1:
sgp30ebbrE7.a1:
sgp15ebbrE7.b1:
sgp30ebbrE7.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
07/30/2002 | 1800 | 07/30/2002 | 1829 |
Subject: | SGP/EBBR/E7 - Data Reported as Zero following Logger Replacement |
DataStreams: | sgp5ebbrE7.a1, sgp15ebbrE7.a1, sgp15ebbrE7.b1, sgp30ebbrE7.a1, sgp30ebbrE7.b1 |
Description: | The data was reported as zero after a data logger replacement. |
Measurements: | sgp5ebbrE7.a1:
sgp30ebbrE7.a1:
sgp15ebbrE7.a1:
sgp15ebbrE7.b1:
sgp30ebbrE7.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
06/11/2003 | 1730 | 07/15/2003 | 2000 |
Subject: | SGP/EBBR/E7 - Soil Heat Flow #5 Incorrect |
DataStreams: | sgp15ebbrE7.a1, sgp15ebbrE7.b1, sgp30ebbrE7.a1, sgp30ebbrE7.b1 |
Description: | Soil Heat Flow Plate #5 data was intermittently incorrect at first (values too small negative), then was almost constantly so during the last half of the period. Comparison of the individual soil heat flows will quickly show the times that soil heat flow #5 was incorrect. |
Measurements: | sgp15ebbrE7.a1:
sgp30ebbrE7.a1:
sgp15ebbrE7.b1:
sgp30ebbrE7.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
04/22/2003 | 1650 | 04/22/2003 | 1720 |
Subject: | SGP/EBBR/E7 - 6 Month Checks |
DataStreams: | sgp5ebbrE7.a1, sgp15ebbrE7.a1, sgp15ebbrE7.b1, sgp30ebbrE7.a1, sgp30ebbrE7.b1 |
Description: | Many measurements were incorrect while the AEM was positioned with both aspirators at the same height for comparison checks. |
Measurements: | sgp5ebbrE7.a1:
sgp15ebbrE7.a1:
sgp30ebbrE7.a1:
sgp15ebbrE7.b1:
sgp30ebbrE7.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
07/27/2003 | 1330 | 10/07/2003 | 2000 |
Subject: | SGP/EBBR/E7 - AEM Malfunction, Some Data Incorrect |
DataStreams: | sgp5ebbrE7.a1, sgp15ebbrE7.a1, sgp15ebbrE7.b1, sgp30ebbrE7.a1, sgp30ebbrE7.b1 |
Description: | After a while, the teflon slides on the AEMs warp from heat and use. This tends to make the AEM drag, jam, and get hung. This happened at E7 EBBR. Replacement of the AEM resolved the problem. |
Measurements: | sgp5ebbrE7.a1:
sgp15ebbrE7.a1:
sgp30ebbrE7.a1:
sgp15ebbrE7.b1:
sgp30ebbrE7.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
08/26/2003 | 1800 | 08/26/2003 | 1800 |
Subject: | SGP/EBBR/E7 - Data all zero |
DataStreams: | sgp5ebbrE7.a1, sgp15ebbrE7.a1, sgp15ebbrE7.b1, sgp30ebbrE7.a1, sgp30ebbrE7.b1 |
Description: | Data values were all zero after restarting the CR10 datalogger. |
Measurements: | sgp5ebbrE7.a1:
sgp30ebbrE7.a1:
sgp15ebbrE7.a1:
sgp15ebbrE7.b1:
sgp30ebbrE7.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
08/26/2003 | 1830 | 08/26/2003 | 1830 |
Subject: | SGP/EBBR/E7 - Energy Storage Incorrect, Fluxes Incorrect |
DataStreams: | sgp30ebbrE7.a1, sgp30ebbrE7.b1 |
Description: | The half hour after restart of the CR10 datalogger, the soil temperatures for the beginning of the period are missing. Therefore the soil energy storage and surface flux values are also incorrect. |
Measurements: | sgp30ebbrE7.a1:
sgp30ebbrE7.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
08/29/2003 | 0230 | 09/05/2003 | 1730 |
Subject: | SGP/EBBR/E7 - Water in Net Radiometer Domes; Surface Fluxes are Incorrect |
DataStreams: | sgp5ebbrE7.a1, sgp15ebbrE7.a1, sgp15ebbrE7.b1, sgp30ebbrE7.a1, sgp30ebbrE7.b1 |
Description: | The net radiometer top dome was punctured by migrating birds. This alone does not cause incorrect net radiation measurements. However, when it subsequently rains, water collects in the bottom dome, causing the net radiation measurements to be too large during the day and too small at night. |
Measurements: | sgp5ebbrE7.a1:
sgp15ebbrE7.a1:
sgp30ebbrE7.a1:
sgp15ebbrE7.b1:
sgp30ebbrE7.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
03/07/2003 | 1500 | 10/12/2003 | 2355 |
Subject: | SGP/EBBR/E7 - Pressure Sensor Data Incorrect |
DataStreams: | sgp5ebbrE7.a1, sgp15ebbrE7.b1, sgp30ebbrE7.b1 |
Description: | The E7 pressure sensor suffered from spikes in pressure, which were related to increases in voltage during the day as the solar panels charged the battery. These spikes were not of a magnitude that would affect the 30 minute surface fluxes. Replacement of the pressure sensor solved the problem. |
Measurements: | sgp5ebbrE7.a1:
sgp15ebbrE7.b1:
sgp30ebbrE7.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
04/10/2001 | 1913 | 04/10/2001 | 2000 |
10/25/2001 | 1444 | 10/25/2001 | 1530 |
05/07/2002 | 1624 | 05/07/2002 | 1705 |
11/19/2002 | 2009 | 11/19/2002 | 2120 |
11/22/2002 | 1735 | 11/22/2002 | 1750 |
04/22/2003 | 1654 | 04/22/2003 | 1730 |
Subject: | SGP/SMOS/E7 - 6-month Calibration Checks |
DataStreams: | sgp1smosE7.a1, sgp1smosE7.b1, sgp30smosE7.a1, sgp30smosE7.b1, sgp1440smosE7.a1 |
Description: | During the time periods specified, the SMOS.E7 tower was lowered for 6-month Calibration Checks. During these times wind data are incorrect and temperature and humidity data may be incorrect. Note, exact times when tower was down or maintenance was being performed is sometimes unknown. Users should use the remaining data from these days with caution. |
Measurements: | sgp1440smosE7.a1:
sgp30smosE7.b1:
sgp1smosE7.a1:
sgp30smosE7.a1:
sgp1smosE7.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
11/04/2003 | 2144 | 11/04/2003 | 2230 |
04/06/2004 | 1958 | 04/06/2004 | 2040 |
10/05/2004 | 1939 | 10/05/2004 | 2020 |
04/19/2005 | 2042 | 04/19/2005 | 2135 |
11/01/2005 | 2127 | 11/01/2005 | 2210 |
05/02/2006 | 1945 | 05/02/2006 | 2025 |
10/17/2006 | 1945 | 10/17/2006 | 2030 |
Subject: | SGP/SMOS/E7 - 6-month Calibration Checks |
DataStreams: | sgp1smosE7.b1, sgp30smosE7.b1, sgp1440smosE7.b1 |
Description: | During the time periods specified, the SMOS.E7 tower was lowered for 6-month Calibration Checks. During these times wind data are incorrect and temperature and humidity data may be incorrect. Note, exact times when tower was down or maintenance was being performed is sometimes unknown. Users should use the remaining data from these days with caution. Calibration results are available from the OMIS database at http://www.ops.sgp.arm.gov:591/smos6cal/default.htm To view all 6-month calibration reports leave the date time entry blank. |
Measurements: | sgp1440smosE7.b1:
sgp30smosE7.b1:
sgp1smosE7.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
06/08/2004 | 1900 | 06/08/2004 | 2000 |
Subject: | SGP/SWATS/E7 - Incorrect Soil Temp and Moisture Data |
DataStreams: | sgpswatsE7.00, sgpswatsE7.b1 |
Description: | The soil temperature and temperature rise readings from all depths on both the east and west profiles (tsoil_W, tsoil_E, trise_E, trise_W) were incorrect. This also caused the matric potential (soilwatpot_E, soilwatpot_W) and water content (watcont_E, watcont_W) data to be incorrect. The reference temperature reading (tref) is suspect. |
Measurements: | sgpswatsE7.00:
sgpswatsE7.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
06/17/2004 | 1700 | 06/23/2004 | 1900 |
Subject: | SGP/SWATS/E7 - Incorrect Soil Moisture Data |
DataStreams: | sgpswatsE7.00, sgpswatsE7.b1 |
Description: | The temperature rise readings from the 35-cm depth on the east profile (trise_E) are noisy and inconsistent with the rest of the data. This also causes the matric potential (soilwatpot_E) and water content (watcont_E) data for the 35-cm depth to be suspect. |
Measurements: | sgpswatsE7.00:
sgpswatsE7.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
07/04/2004 | 1200 | 07/09/2004 | 1630 |
Subject: | SGP/SWATS/E7 - Missing Data |
DataStreams: | sgpswatsE7.00, sgpswatsE7.b1 |
Description: | A power outage caused the instrument to lose its operating program, and measurements could not be taken or recorded. |
Measurements: | sgpswatsE7.00:
sgpswatsE7.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
07/04/2004 | 1341 | 07/09/2004 | 1704 |
Subject: | SGP/SMOS/E7 - datalogger down due to power outage |
DataStreams: | sgp1smosE7.b1, sgp30smosE7.b1, sgp1440smosE7.b1 |
Description: | A power outage caused the datalogger to lose it's program resulting in no data being collected during the time period. |
Measurements: | sgp1440smosE7.b1:
sgp30smosE7.b1:
sgp1smosE7.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
08/10/2004 | 1925 | 08/24/2004 | 1820 |
Subject: | SGP/EBBR/E7 - Pressure Too High |
DataStreams: | sgp5ebbrE7.b1, sgp15ebbrE7.b1, sgp30ebbrE7.b1 |
Description: | When data collection resumed after a missing period, the barometer pressure had become very high, 102 kPa, which was not correct. This condition resulted from an incorrect calibration being used. Sensible heat flux was overestimated by about 4% and latent heat flux underestimated by about 4% because of the high pressure readings. |
Measurements: | sgp15ebbrE7.b1:
sgp30ebbrE7.b1:
sgp5ebbrE7.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
08/04/2004 | 1705 | 08/10/2004 | 1925 |
Subject: | SGP/EBBR/E7 - Data Missing |
DataStreams: | sgp5ebbrE7.b1, sgp15ebbrE7.b1, sgp30ebbrE7.b1 |
Description: | A power outage resulted in missing data for the indicated period. |
Measurements: | sgp15ebbrE7.b1:
sgp5ebbrE7.b1:
sgp30ebbrE7.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
04/01/2001 | 0000 | 03/08/2005 | 2015 |
Subject: | SGP/SMOS/E7 - Reprocess: Wind direction offset |
DataStreams: | sgp1smosE7.b1, sgp30smosE7.b1 |
Description: | When the SGP.E7 SMOS tower was installed it was not aligned properly resulting in a 6 degree offset. On 3/08/05, the datalogger program was modified to correct for this offset. |
Measurements: | sgp30smosE7.b1:
sgp1smosE7.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
04/01/2001 | 0000 | 03/22/2005 | 1900 |
Subject: | SGP/EBBR/E7 - Improved EBBR CR10 Program |
DataStreams: | sgp30ebbrE7.b1 |
Description: | Effective 20050322.1900, the EBBR.E7 CR10 program was revised to improve the quality of the primary measurements as follows: 1) An RMS procedure is used to determine max and min limits of acceptable soil heat flow. This is applied to the individual soil sets. Measurements outside the limits are rejected and the measurements within the limits are used to calculate the average soil heat flow. 2) Max and min limits are used to determine incorrect values of net radiation, sensible heat flux (h), latent heat flux (e), and automatic exchange mechanism (AEM) signal. If AEM signal is outside the limits, h and e are set to 999s. If net radiation is outside the limits, h and e are set to 999s. If h or e are outside the limits, h and e are set to 999s. Virtually no incorrect soil measurement will affect the primary measurements of h and e. By setting h and e to 999s, it can be easily seen that the primary variables are incorrect; no other interpretation is possible. Prior to 20050322, the improved CR10 program was NOT in effect. DQRs have been submitted for known instances of incorrect soil measurements which affected the quality of the primary measurements of h and e. Note: the DQR begin date is the begin date of the sgp30ebbrE7.b1 data stream. The earlier version of the CR10 program was also used on previous EBBR datastream names (e.g. sgp30ebbrE7.a1). |
Measurements: | sgp30ebbrE7.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
09/20/2005 | 2030 | 10/07/2005 | 1530 |
Subject: | SGP/EBBR/E7 - Data Missing |
DataStreams: | sgp5ebbrE7.b1, sgp15ebbrE7.b1, sgp30ebbrE7.b1 |
Description: | Data was missing because of a communication problem. However, previously missing data from 10/07-18 was recovered from the EBRR storage module and ingested, thereby reducing the data lost period significantly. |
Measurements: | sgp15ebbrE7.b1:
sgp5ebbrE7.b1:
sgp30ebbrE7.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
09/14/2005 | 0000 | 09/20/2005 | 2000 |
Subject: | SGP/EBBR/E7 - Net Radiation Incorrect; Sensible and Latent Heat Fluxes Incorrect |
DataStreams: | sgp5ebbrE7.b1, sgp15ebbrE7.b1, sgp30ebbrE7.b1 |
Description: | The top dome of the net radiometer was cracked; net radiation, and sensible and latent heat flux measurements were incorrect. |
Measurements: | sgp15ebbrE7.b1:
sgp30ebbrE7.b1:
sgp5ebbrE7.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/13/2003 | 0000 | 07/22/2005 | 2359 |
Subject: | SGP/EBBR/E7 - metadata corrections |
DataStreams: | sgp5ebbrE7.b1, sgp15ebbrE7.b1, sgp30ebbrE7.b1 |
Description: | On 20050723, a series of metadata corrections and additions were completed. These metadata changes apply to all EBBR.E7 data collected by ARM back to the installation of the instrument in May 1993. Please see the current metadata for correct information. These changes do not affect data values or quality. The changes are summarized below: 1) Update of "sensor location" information 2) Addition of installation dates for the systems 3) Correction of soil moisture units (from "by volume" to "gravimetric") |
Measurements: | sgp5ebbrE7.b1:
sgp30ebbrE7.b1:
sgp15ebbrE7.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
03/07/2006 | 1500 | 03/07/2006 | 2030 |
03/30/2006 | 2230 | 04/03/2006 | 1930 |
Subject: | SGP/EBBR/E7 - Missing Data |
DataStreams: | sgp5ebbrE7.b1, sgp15ebbrE7.b1, sgp30ebbrE7.b1 |
Description: | on 3/7/06 the data was missing during a battery and AC/DC charger replacement. During the 3/30/06-4/3/06 period the data was missing for an unknown reason. |
Measurements: | sgp15ebbrE7.b1:
sgp5ebbrE7.b1:
sgp30ebbrE7.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
08/28/2006 | 0330 | 09/04/2006 | 2230 |
Subject: | SGP/EBBR/E7 - Data Missing |
DataStreams: | sgp5ebbrE7.b1, sgp15ebbrE7.b1, sgp30ebbrE7.b1 |
Description: | Data was missing for this period. |
Measurements: | sgp15ebbrE7.b1:
sgp5ebbrE7.b1:
sgp30ebbrE7.b1:
|