DQR ID | Subject | Data Streams Affected |
---|---|---|
D030325.2 | SGP/THWAPS/B6 - Loss of temperature and RH for 8 hours | sgpthwapsB6.a1, sgpthwapsB6.b1 |
D050812.1 | SGP/THWAPS/B4 - Minor biases in humidity and saturation vapor pressure | sgpthwapsB4.b1 |
D050812.12 | SGP/THWAPS/C1 - Minor bias in saturation vapor pressure | sgpthwapsC1.b1 |
D050812.4 | SGP/THWAPS/B5 - Minor biases in humidity and saturation vapor pressure | sgpthwapsB5.b1 |
D050812.7 | SGP/THWAPS/B6 - Minor biases in humidity and saturation vapor pressure | sgpthwapsB6.b1 |
D050813.2 | SGP/THWAPS/B1 - Minor bias in saturation vapor pressure | sgpthwapsB1.b1 |
Start Date | Start Time | End Date | End Time |
---|---|---|---|
03/18/2003 | 1430 | 03/18/2003 | 2205 |
Subject: | SGP/THWAPS/B6 - Loss of temperature and RH for 8 hours |
DataStreams: | sgpthwapsB6.a1, sgpthwapsB6.b1 |
Description: | The UPS for this system failed resulting in loss of power to the HMP233 unit. As a result, the temperature and RH values were read as zero by the data logger. SiteOps replaced the UPS and all appears well now. |
Measurements: | sgpthwapsB6.a1:
sgpthwapsB6.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
09/21/1999 | 0000 | 07/30/2005 | 1722 |
Subject: | SGP/THWAPS/B4 - Minor biases in humidity and saturation vapor pressure |
DataStreams: | sgpthwapsB4.b1 |
Description: | The THWAPS humidity sensor output was scaled so that the instrument output voltage range (0-1VDC) represented 0-100 %RH. Comparisons with the co-located chilled mirror sensor at the CF suggested that the THWAPS RH sensor was reading artifically low at high humidities because of this 100 %RH maximum. The scaling of the system was changed so that 0-1 VDC now represents 0-110 %RH. This resulted in a slight loss of precision in the measurements, but since the RH measurement is only accurate to 2-3 %RH at best, this isn't a significant problem. The saturation vapor correction when temps are below 0C contained an error in the multiplier. The incorrect multiplier only equates to an error of 0.01 kPa which is less than the stated uncertainty of the measurement (+/- 0.035 kPa). |
Measurements: | sgpthwapsB4.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
09/21/1999 | 0000 | 08/10/2005 | 1445 |
Subject: | SGP/THWAPS/C1 - Minor bias in saturation vapor pressure |
DataStreams: | sgpthwapsC1.b1 |
Description: | The saturation vapor correction when temps are below 0C contained an error in the multiplier. The incorrect multiplier only equates to an error of 0.01 kPa which is less than the stated uncertainty of the measurement (+/- 0.035 kPa). |
Measurements: | sgpthwapsC1.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
09/21/1999 | 0000 | 07/31/2005 | 1714 |
Subject: | SGP/THWAPS/B5 - Minor biases in humidity and saturation vapor pressure |
DataStreams: | sgpthwapsB5.b1 |
Description: | The THWAPS humidity sensor output was scaled so that the instrument output voltage range (0-1VDC) represented 0-100 %RH. Comparisons with the co-located chilled mirror sensor at the CF suggested that the THWAPS RH sensor was reading artifically low at high humidities because of this 100 %RH maximum. The scaling of the system was changed so that 0-1 VDC now represents 0-110 %RH. This resulted in a slight loss of precision in the measurements, but since the RH measurement is only accurate to 2-3 %RH at best, this isn't a significant problem. The saturation vapor correction when temps are below 0C contained an error in the multiplier. The incorrect multiplier only equates to an error of 0.01 kPa which is less than the stated uncertainty of the measurement (+/- 0.035 kPa). |
Measurements: | sgpthwapsB5.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
09/21/1999 | 0000 | 07/30/2005 | 2355 |
Subject: | SGP/THWAPS/B6 - Minor biases in humidity and saturation vapor pressure |
DataStreams: | sgpthwapsB6.b1 |
Description: | The THWAPS humidity sensor output was scaled so that the instrument output voltage range (0-1VDC) represented 0-100 %RH. Comparisons with the co-located chilled mirror sensor at the CF suggested that the THWAPS RH sensor was reading artifically low at high humidities because of this 100 %RH maximum. The scaling of the system was changed so that 0-1 VDC now represents 0-110 %RH. This resulted in a slight loss of precision in the measurements, but since the RH measurement is only accurate to 2-3 %RH at best, this isn't a significant problem. The saturation vapor correction when temps are below 0C contained an error in the multiplier. The incorrect multiplier only equates to an error of 0.01 kPa which is less than the stated uncertainty of the measurement (+/- 0.035 kPa). |
Measurements: | sgpthwapsB6.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
09/21/1999 | 0000 | 08/01/2005 | 2034 |
Subject: | SGP/THWAPS/B1 - Minor bias in saturation vapor pressure |
DataStreams: | sgpthwapsB1.b1 |
Description: | The saturation vapor correction when temps are below 0C contained an error in the multiplier. The incorrect multiplier only equates to an error of 0.01 kPa which is less than the stated uncertainty of the measurement (+/- 0.035 kPa). |
Measurements: | sgpthwapsB1.b1:
|