Data Quality Reports for Session: 108566 User: rao Completed: 10/24/2007


TABLE OF CONTENTS

DQR IDSubjectData Streams Affected
D030620.1SGP/EBBR/E7 - Soil Heat Flow #5 Incorrectsgp15ebbrE7.a1, sgp15ebbrE7.b1, sgp30ebbrE7.a1, sgp30ebbrE7.b1
D030729.3SGP/EBBR/E7 - AEM Malfunction, Some Data Incorrectsgp15ebbrE7.a1, sgp15ebbrE7.b1, sgp30ebbrE7.a1, sgp30ebbrE7.b1, sgp5ebbrE7.a1
D030919.1SGP/EBBR/E7 - Data all zerosgp15ebbrE7.a1, sgp15ebbrE7.b1, sgp30ebbrE7.a1, sgp30ebbrE7.b1, sgp5ebbrE7.a1
D030919.3SGP/EBBR/E7 - Water in Net Radiometer Domes; Surface Fluxes are Incorrectsgp15ebbrE7.a1, sgp15ebbrE7.b1, sgp30ebbrE7.a1, sgp30ebbrE7.b1, sgp5ebbrE7.a1


DQRID : D030620.1
Start DateStart TimeEnd DateEnd Time
06/11/2003173007/15/20032000
Subject:
SGP/EBBR/E7 - Soil Heat Flow #5 Incorrect
DataStreams:sgp15ebbrE7.a1, sgp15ebbrE7.b1, sgp30ebbrE7.a1, sgp30ebbrE7.b1
Description:
Soil Heat Flow Plate #5 data was intermittently incorrect at first 
(values too small negative), then was almost constantly so during the 
last half of the period.

Comparison of the individual soil heat flows will quickly show the times
that soil heat flow #5 was incorrect.
Measurements:sgp15ebbrE7.a1:
  • Soil heat flow 5(mv_hft5)

sgp30ebbrE7.a1:
  • average surface soil heat flow(ave_shf)
  • soil heat flow, site 5(g5)
  • 5 cm soil heat flow corrected for soil moisture content, site 5(c_shf5)
  • latent heat flux(e)
  • 5 cm soil heat flow, site 5(shf5)
  • h(h)

sgp15ebbrE7.b1:
  • Soil heat flow 5(mv_hft5)

sgp30ebbrE7.b1:
  • average surface soil heat flow(ave_shf)
  • 5 cm soil heat flow corrected for soil moisture content, site 5(c_shf5)
  • h(h)
  • latent heat flux(e)
  • 5 cm soil heat flow, site 5(shf5)
  • soil heat flow, site 5(g5)


Back To Table of Contents

DQRID : D030729.3
Start DateStart TimeEnd DateEnd Time
07/27/2003133010/07/20032000
Subject:
SGP/EBBR/E7  - AEM Malfunction, Some Data Incorrect
DataStreams:sgp15ebbrE7.a1, sgp15ebbrE7.b1, sgp30ebbrE7.a1, sgp30ebbrE7.b1, sgp5ebbrE7.a1
Description:
After a while, the teflon slides on the AEMs warp from
heat and use.  This tends to make the AEM drag, jam, and get hung.
This happened at E7 EBBR.

Replacement of the AEM resolved the problem.
Measurements:sgp5ebbrE7.a1:
  • top air temperature(tair_top)
  • bottom vapor pressure(vp_bot)
  • Temperature of the top humidity chamber(thum_top)
  • Temperature of bottom humidity sensor chamber(thum_bot)
  • top vapor pressure(vp_top)
  • Top humidity(hum_top)
  • bottom air temperature(tair_bot)
  • Bottom humidity(hum_bot)

sgp15ebbrE7.a1:
  • Left air temperature(tair_l)
  • Right air temperature(tair_r)

sgp30ebbrE7.a1:
  • ratio of sensible/latent heat fluxes (Bowen ratio)(bowen)
  • top air temperature(tair_top)
  • Top humidity(hum_top)
  • top vapor pressure(vp_top)
  • bottom air temperature(tair_bot)
  • Temperature of bottom humidity sensor chamber(thum_bot)
  • bottom vapor pressure(vp_bot)
  • latent heat flux(e)
  • h(h)
  • Bottom humidity(hum_bot)
  • Temperature of the top humidity chamber(thum_top)

sgp15ebbrE7.b1:
  • Right air temperature(tair_r)
  • Left air temperature(tair_l)

sgp30ebbrE7.b1:
  • ratio of sensible/latent heat fluxes (Bowen ratio)(bowen)
  • bottom vapor pressure(vp_bot)
  • Top humidity(hum_top)
  • top air temperature(tair_top)
  • bottom air temperature(tair_bot)
  • Bottom humidity(hum_bot)
  • Temperature of bottom humidity sensor chamber(thum_bot)
  • h(h)
  • top vapor pressure(vp_top)
  • latent heat flux(e)
  • Temperature of the top humidity chamber(thum_top)


Back To Table of Contents

DQRID : D030919.1
Start DateStart TimeEnd DateEnd Time
08/26/2003180008/26/20031800
Subject:
SGP/EBBR/E7 - Data all zero
DataStreams:sgp15ebbrE7.a1, sgp15ebbrE7.b1, sgp30ebbrE7.a1, sgp30ebbrE7.b1, sgp5ebbrE7.a1
Description:
Data values were all zero after restarting the CR10 datalogger.
Measurements:sgp5ebbrE7.a1:
  • Temperature of the top humidity chamber(thum_top)
  • Reference Thermistor Temperature(tref)
  • Top humidity(hum_top)
  • Retrieved pressure profile(pres)
  • vector wind speed(res_ws)
  • standard deviation of wind direction (sigma theta)(sigma_wd)
  • net radiation(q)
  • Bottom humidity(hum_bot)
  • bottom vapor pressure(vp_bot)
  • Temperature of bottom humidity sensor chamber(thum_bot)
  • top vapor pressure(vp_top)
  • wind direction (relative to true north)(wind_d)
  • Home signal(home)
  • top air temperature(tair_top)
  • scalar wind speed(wind_s)
  • bottom air temperature(tair_bot)

sgp30ebbrE7.a1:
  • wind direction (relative to true north)(wind_d)
  • 0-5 cm change in soil heat storage with time, site 3(ces3)
  • soil heat flow, site 2(g2)
  • top air temperature(tair_top)
  • average surface soil heat flow(ave_shf)
  • Exchange mechanism position indicator (0 to 15 min)(home_15)
  • vector wind speed(res_ws)
  • volumetric soil moisture, site 5(sm5)
  • 0-5 cm change in soil heat storage with time, site 2(ces2)
  • 0-5 cm integrated soil temperature, site 2(ts2)
  • bottom air temperature(tair_bot)
  • volumetric soil moisture, site 4(sm4)
  • standard deviation of wind direction (sigma theta)(sigma_wd)
  • 0-5 cm integrated soil temperature, site 5(ts5)
  • Temperature of bottom humidity sensor chamber(thum_bot)
  • 0-5 cm integrated soil temperature, site 4(ts4)
  • volumetric soil moisture, site 2(sm2)
  • Soil heat capacity 2(cs2)
  • 5 cm soil heat flow corrected for soil moisture content, site 1(c_shf1)
  • volumetric soil moisture, site 1(sm1)
  • latent heat flux(e)
  • 0-5 cm change in soil heat storage with time, site 4(ces4)
  • soil heat flow, site 4(g4)
  • soil heat flow, site 3(g3)
  • Temperature of the top humidity chamber(thum_top)
  • 5 cm soil heat flow corrected for soil moisture content, site 2(c_shf2)
  • Soil heat capacity 5(cs5)
  • 5 cm soil heat flow corrected for soil moisture content, site 5(c_shf5)
  • 0-5 cm change in soil heat storage with time, site 5(ces5)
  • Soil heat capacity 3(cs3)
  • Retrieved pressure profile(pres)
  • Reference Thermistor Temperature(tref)
  • Soil heat capacity 1(cs1)
  • 5 cm soil heat flow, site 5(shf5)
  • 5 cm soil heat flow corrected for soil moisture content, site 4(c_shf4)
  • net radiation(q)
  • Exchange mechanism position indicator (15 to 30 min)(home_30)
  • Soil heat capacity 4(cs4)
  • 5 cm soil heat flow, site 1(shf1)
  • ratio of sensible/latent heat fluxes (Bowen ratio)(bowen)
  • bottom vapor pressure(vp_bot)
  • h(h)
  • 5 cm soil heat flow, site 4(shf4)
  • 5 cm soil heat flow corrected for soil moisture content, site 3(c_shf3)
  • soil heat flow, site 1(g1)
  • Top humidity(hum_top)
  • soil heat flow, site 5(g5)
  • top vapor pressure(vp_top)
  • scalar wind speed(wind_s)
  • 0-5 cm integrated soil temperature, site 3(ts3)
  • 5 cm soil heat flow, site 2(shf2)
  • 5 cm soil heat flow, site 3(shf3)
  • 0-5 cm change in soil heat storage with time, site 2(ces1)
  • Bottom humidity(hum_bot)
  • 0-5 cm integrated soil temperature, site 2(ts1)
  • volumetric soil moisture, site 3(sm3)

sgp15ebbrE7.a1:
  • Atmospheric pressure(mv_pres)
  • Soil moisture 5(r_sm5)
  • Soil temperature 5(rr_ts5)
  • Left relative humidity(mv_hum_l)
  • Soil heat flow 5(mv_hft5)
  • Soil moisture 2(r_sm2)
  • Soil temperature 4(rr_ts4)
  • Soil heat flow 4(mv_hft4)
  • Soil moisture 3(r_sm3)
  • Battery(bat)
  • Wind direction (relative to true north)(mv_wind_d)
  • Left air temperature(tair_l)
  • Right air temperature(tair_r)
  • Soil moisture 2(rr_sm2)
  • Soil moisture 5(rr_sm5)
  • Soil moisture 1(r_sm1)
  • Soil moisture 3(rr_sm3)
  • Soil heat flow 1(mv_hft1)
  • Soil moisture 4(r_sm4)
  • Temperature of left humidity sensor chamber(rr_thum_l)
  • Temperature of right humidity sensor chamber(rr_thum_r)
  • Soil moisture 4(rr_sm4)
  • Right relative humidity(mv_hum_r)
  • Soil temperature 2(rr_ts2)
  • Soil moisture 1(rr_sm1)
  • Soil temperature 3(rr_ts3)
  • Soil heat flow 2(mv_hft2)
  • Soil heat flow 3(mv_hft3)
  • Net radiation(mv_q)
  • Home signal(mv_home)
  • Soil temperature 1(rr_ts1)
  • Reference temperature(rr_tref)
  • scalar wind speed(wind_s)

sgp15ebbrE7.b1:
  • Net radiation(mv_q)
  • Soil moisture 2(r_sm2)
  • Temperature of left humidity sensor chamber(rr_thum_l)
  • Soil moisture 3(r_sm3)
  • Soil heat flow 3(mv_hft3)
  • Soil heat flow 4(mv_hft4)
  • Soil moisture 5(r_sm5)
  • Home signal(mv_home)
  • Wind direction (relative to true north)(mv_wind_d)
  • Soil heat flow 5(mv_hft5)
  • Reference temperature(rr_tref)
  • Left relative humidity(mv_hum_l)
  • scalar wind speed(wind_s)
  • Battery(bat)
  • Soil heat flow 1(mv_hft1)
  • Right relative humidity(mv_hum_r)
  • Temperature of right humidity sensor chamber(rr_thum_r)
  • Soil temperature 4(rr_ts4)
  • Left air temperature(tair_l)
  • Soil temperature 3(rr_ts3)
  • Soil moisture 4(r_sm4)
  • Soil temperature 5(rr_ts5)
  • Soil moisture 1(r_sm1)
  • Soil heat flow 2(mv_hft2)
  • Right air temperature(tair_r)
  • Soil temperature 1(rr_ts1)
  • Atmospheric pressure(mv_pres)
  • Soil temperature 2(rr_ts2)

sgp30ebbrE7.b1:
  • volumetric soil moisture, site 3(sm3)
  • wind direction (relative to true north)(wind_d)
  • volumetric soil moisture, site 2(sm2)
  • bottom air temperature(tair_bot)
  • Exchange mechanism position indicator (0 to 15 min)(home_15)
  • volumetric soil moisture, site 4(sm4)
  • average surface soil heat flow(ave_shf)
  • Temperature of bottom humidity sensor chamber(thum_bot)
  • 5 cm soil heat flow, site 4(shf4)
  • 0-5 cm integrated soil temperature, site 4(ts4)
  • volumetric soil moisture, site 5(sm5)
  • Soil heat capacity 2(cs2)
  • 5 cm soil heat flow, site 3(shf3)
  • 0-5 cm integrated soil temperature, site 5(ts5)
  • top air temperature(tair_top)
  • volumetric soil moisture, site 1(sm1)
  • 0-5 cm change in soil heat storage with time, site 2(ces2)
  • 0-5 cm integrated soil temperature, site 2(ts1)
  • top vapor pressure(vp_top)
  • scalar wind speed(wind_s)
  • latent heat flux(e)
  • vector wind speed(res_ws)
  • Top humidity(hum_top)
  • bottom vapor pressure(vp_bot)
  • ratio of sensible/latent heat fluxes (Bowen ratio)(bowen)
  • standard deviation of wind direction (sigma theta)(sigma_wd)
  • soil heat flow, site 3(g3)
  • 5 cm soil heat flow, site 5(shf5)
  • 5 cm soil heat flow corrected for soil moisture content, site 3(c_shf3)
  • soil heat flow, site 2(g2)
  • Soil heat capacity 1(cs1)
  • Bottom humidity(hum_bot)
  • Reference Thermistor Temperature(tref)
  • 0-5 cm integrated soil temperature, site 2(ts2)
  • Soil heat capacity 4(cs4)
  • h(h)
  • Temperature of the top humidity chamber(thum_top)
  • Soil heat capacity 5(cs5)
  • Retrieved pressure profile(pres)
  • 0-5 cm change in soil heat storage with time, site 5(ces5)
  • Exchange mechanism position indicator (15 to 30 min)(home_30)
  • 5 cm soil heat flow corrected for soil moisture content, site 5(c_shf5)
  • 0-5 cm change in soil heat storage with time, site 4(ces4)
  • net radiation(q)
  • 0-5 cm change in soil heat storage with time, site 2(ces1)
  • 0-5 cm integrated soil temperature, site 3(ts3)
  • soil heat flow, site 1(g1)
  • 5 cm soil heat flow corrected for soil moisture content, site 1(c_shf1)
  • soil heat flow, site 4(g4)
  • Soil heat capacity 3(cs3)
  • 0-5 cm change in soil heat storage with time, site 3(ces3)
  • 5 cm soil heat flow corrected for soil moisture content, site 2(c_shf2)
  • 5 cm soil heat flow corrected for soil moisture content, site 4(c_shf4)
  • soil heat flow, site 5(g5)
  • 5 cm soil heat flow, site 2(shf2)
  • 5 cm soil heat flow, site 1(shf1)


Back To Table of Contents

DQRID : D030919.3
Start DateStart TimeEnd DateEnd Time
08/29/2003023009/05/20031730
Subject:
SGP/EBBR/E7 - Water in Net Radiometer Domes; Surface Fluxes are Incorrect
DataStreams:sgp15ebbrE7.a1, sgp15ebbrE7.b1, sgp30ebbrE7.a1, sgp30ebbrE7.b1, sgp5ebbrE7.a1
Description:
The net radiometer top dome was punctured by migrating birds.  This alone does not cause 
incorrect net radiation measurements.  However, when it subsequently rains, water collects 
in the bottom dome, causing the net radiation measurements to be too large during the 
day and too small at night.
Measurements:sgp5ebbrE7.a1:
  • net radiation(q)

sgp15ebbrE7.a1:
  • Net radiation(mv_q)

sgp30ebbrE7.a1:
  • latent heat flux(e)
  • h(h)
  • net radiation(q)

sgp15ebbrE7.b1:
  • Net radiation(mv_q)

sgp30ebbrE7.b1:
  • net radiation(q)
  • h(h)
  • latent heat flux(e)


Back To Table of Contents



END OF DATA