DQR ID | Subject | Data Streams Affected |
---|---|---|
D060426.8 | TWP/SMET/C3 - ORG data noisy due to degraded ground | twpsmet60sC3.b1 |
D060502.3 | TWP/SMET/C3 - Reprocess: Windspeed2 calibration error | twpsmet60sC3.b1 |
D060601.1 | TWP/MWR/C3 - Site shutdown | twpmwrC3.00, twpmwrlosC3.a1, twpmwrlosC3.b1, twpmwrtipC3.a1 |
D060627.1 | TWP/SMET/C3 - Anemometer Readings Incorrect | twpsmet60sC3.b1 |
D060818.3 | TWP/SMET/C3 - Reprocess: Barometric Data Changed from hPa to kPa | twpsmet60sC3.b1 |
D061011.4 | TWP/SMET/C3 - Reprocess: Tipping bucket rain gauge added | twpsmet60sC3.b1 |
D061114.4 | TWP/MWR/C3 - Sun in field of view of radiometer | twpmwrlosC3.b1, twpmwrtipC3.a1 |
Start Date | Start Time | End Date | End Time |
---|---|---|---|
12/01/2005 | 0000 | 08/24/2006 | 2359 |
Subject: | TWP/SMET/C3 - ORG data noisy due to degraded ground |
DataStreams: | twpsmet60sC3.b1 |
Description: | SMET Rain Data began to be noisy during December 2005 and the problem slowly became worse over time so that in February 2006 the ORG was reporting with a constant background value of around 0.10 mm/hr rain rate. ORG voltage showed a near constant value above the 85mV threshold. The ground for the ORG had become degraded and was lost due to corrosion. |
Measurements: | twpsmet60sC3.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
04/27/2006 | 2330 | 05/02/2006 | 0201 |
Subject: | TWP/SMET/C3 - Reprocess: Windspeed2 calibration error |
DataStreams: | twpsmet60sC3.b1 |
Description: | The lower anemometer was replaced afer being removed in anticipation of cyclone Monica. The calibration coefficient was not changed during this period so the wind speeds are a little low (0.2%). |
Measurements: | twpsmet60sC3.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
04/24/2006 | 0000 | 04/25/2006 | 2259 |
Subject: | TWP/MWR/C3 - Site shutdown |
DataStreams: | twpmwrC3.00, twpmwrlosC3.a1, twpmwrlosC3.b1, twpmwrtipC3.a1 |
Description: | On 4/24, the site was shutdown in preparation for a cyclone. Instruments were back up on 4/25 at 22:59 |
Measurements: | twpmwrlosC3.a1:
twpmwrlosC3.b1:
twpmwrtipC3.a1:
twpmwrC3.00:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
06/27/2006 | 0115 | 06/27/2006 | 0344 |
Subject: | TWP/SMET/C3 - Anemometer Readings Incorrect |
DataStreams: | twpsmet60sC3.b1 |
Description: | The Anemometer readings were incorrect due to the tower being lowered for maintenance. |
Measurements: | twpsmet60sC3.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
12/02/2003 | 0000 | 07/13/2006 | 2219 |
Subject: | TWP/SMET/C3 - Reprocess: Barometric Data Changed from hPa to kPa |
DataStreams: | twpsmet60sC3.b1 |
Description: | Barometric pressure data was converted from hPa to kPa in order to standardize the measurement units among ARM sites and to conform to accepted standard units determined by the scientific community. |
Measurements: | twpsmet60sC3.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
03/12/2002 | 0000 | 09/26/2006 | 1435 |
Subject: | TWP/SMET/C3 - Reprocess: Tipping bucket rain gauge added |
DataStreams: | twpsmet60sC3.b1 |
Description: | A tipping bucket rain gauge was added to the SMET suite of instruments effective 20060926. Two new variables (count and rain amount) were added at the end of the twpsmet60sC1.b1 datastream. When reprocessing of this datastream occurs these variables will be added with -9999 (missing) as the value for dates prior to gauge installation. |
Measurements: | twpsmet60sC3.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/20/2006 | 0000 | 11/09/2006 | 0400 |
Subject: | TWP/MWR/C3 - Sun in field of view of radiometer |
DataStreams: | twpmwrlosC3.b1, twpmwrtipC3.a1 |
Description: | Each day from 9/20 and 10/9 around local noon, there is an increase in the brightness temperature due to the sun being in the field of view of the radiometer. |
Measurements: | twpmwrlosC3.b1:
twpmwrtipC3.a1:
|