DQR ID | Subject | Data Streams Affected |
---|---|---|
D070112.1 | TWP/MMCR/C1 - Reprocess: Height Error | twpmmcrmomC1.00, twpmmcrmomC1.b1, twpmmcrspecmomC1.a0 |
D070129.1 | TWP/MMCR/C1 - Error in recorded heights | twpmmcrmomC1.00, twpmmcrmomC1.b1, twpmmcrspecmomC1.a0 |
Start Date | Start Time | End Date | End Time |
---|---|---|---|
06/16/2006 | 0300 | 01/11/2007 | 1620 |
Subject: | TWP/MMCR/C1 - Reprocess: Height Error |
DataStreams: | twpmmcrmomC1.00, twpmmcrmomC1.b1, twpmmcrspecmomC1.a0 |
Description: | A timing error was found in the PIRAQ MMCR's. It resulted in recorded heights being too high for each radar mode by the following amounts: Mode 1: 24.8756 m too high Mode 2: 25.6249 m too high Mode 3: 33.1176 m too high Mode 4: 33.1176 m too high Range gate spacing was not affected. |
Measurements: | twpmmcrmomC1.b1:
twpmmcrspecmomC1.a0:
twpmmcrmomC1.00:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
06/16/2006 | 0300 | 11/28/2006 | 2359 |
Subject: | TWP/MMCR/C1 - Error in recorded heights |
DataStreams: | twpmmcrmomC1.00, twpmmcrmomC1.b1, twpmmcrspecmomC1.a0 |
Description: | An error in MMCR configuration resulted in a timing error. This caused erroneous height values (too large) to be recorded in the data files. |
Measurements: | twpmmcrmomC1.b1:
twpmmcrspecmomC1.a0:
twpmmcrmomC1.00:
|