Data Quality Reports for Session: 111847 User: troyan Completed: 05/08/2008


TABLE OF CONTENTS

DQR IDSubjectData Streams Affected
D010227.4TWP/MWR/C2 - Excessive wet_window flagstwpmwrlosC2.b1, twpmwrtipC2.a1
D020109.2TWP/SMET/C2 - RH Sensor bad at Naurutwpsmet60sC2.a1, twpsmet60sC2.b1
D040726.1TWP/SMET/C2 - Negative rainfall ratestwpsmet60sC2.b1
D060818.2TWP/SMET/C2 - Reprocess: Barometric Data Changed from hPa to kPatwpsmet60sC2.b1
D061011.3TWP/SMET/C2 - Reprocess: Tipping bucket rain gauge addedtwpsmet60sC2.b1
D061121.1TWP/MWR/C2 - Missing DatatwpmwrlosC2.b1


DQRID : D010227.4
Start DateStart TimeEnd DateEnd Time
01/16/1999090003/08/19992100
11/16/1999090002/09/20002100
12/07/2000000012/17/20002359
Subject:
TWP/MWR/C2 - Excessive wet_window flags
DataStreams:twpmwrlosC2.b1, twpmwrtipC2.a1
Description:
The wet_window flag is set high more than expected from the measured value of liquid water 
path. This may be caused by dew or, if the heater sensivity is slightly misadjusted, by 
the diurnal variation in ambient temperature.

The "wet_window" flag is an indicator of moisture on the MWR window which invalidates the 
measurements of precipitable water vapor and liquid water path. Sometimes this flag can 
be incorrectly set high or low if the heater sensivity is slightly misadjusted. The heater 
adjustment is a resistive device that is dependent on ambient temperature. Another 
indicator of moisture on the window is unreasonably high ( > 3*liquid_retrieval_rms_accuracy ) 
values of "liq".
Measurements:twpmwrlosC2.b1:
  • Water on Teflon window (1=WET, 0=DRY)(wet_window)

twpmwrtipC2.a1:
  • Water on Teflon window (1=WET, 0=DRY)(wet_window)


Back To Table of Contents

DQRID : D020109.2
Start DateStart TimeEnd DateEnd Time
12/16/2001030001/03/20020841
Subject:
TWP/SMET/C2 - RH Sensor bad at Nauru
DataStreams:twpsmet60sC2.a1, twpsmet60sC2.b1
Description:
RH sensor bad from 16 Dec 2001 03 GMT to 3 Jan 2002
Measurements:twpsmet60sC2.b1:
  • Mean Relative Humidity(relh_mean)
  • Relative humidity maximum(relh_max)
  • Std Dev of Relative Humidity or Hardware Error Code(relh_sd)
  • Relative humidity minimum(relh_min)

twpsmet60sC2.a1:
  • Relative humidity minimum(relh_min)
  • Std Dev of Relative Humidity or Hardware Error Code(relh_sd)
  • Mean Relative Humidity(relh_mean)
  • Relative humidity maximum(relh_max)


Back To Table of Contents

DQRID : D040726.1
Start DateStart TimeEnd DateEnd Time
10/21/1998031107/06/20040138
Subject:
TWP/SMET/C2 - Negative rainfall rates
DataStreams:twpsmet60sC2.b1
Description:
Due to limitations of the Zeno dataloggers all voltage measurements
from the optical rain gauge (ORG) were converted to rainfall rates. 
This resulted in negative values for rain rates.  Any value below
0.10 mm/hr should be considered to be 0 mm/hr.  New dataloggers 
alleviated this problem.
Measurements:twpsmet60sC2.b1:
  • Precipitation maximum(precip_max)
  • Precipitation mean(precip_mean)
  • precipitation minimum(precip_min)
  • Precipitation standard deviation(precip_sd)


Back To Table of Contents

DQRID : D060818.2
Start DateStart TimeEnd DateEnd Time
10/21/1998000007/13/20062232
Subject:
TWP/SMET/C2 - Reprocess: Barometric Data Changed from hPa to kPa
DataStreams:twpsmet60sC2.b1
Description:
Barometric pressure data was converted from hPa to kPa in order to standardize the 
measurement units among ARM sites and to conform to accepted standard units determined by the 
scientific community.
Measurements:twpsmet60sC2.b1:
  • Barometric Pressure(atmos_pressure)


Back To Table of Contents

DQRID : D061011.3
Start DateStart TimeEnd DateEnd Time
10/21/1998000011/29/20062014
Subject:
TWP/SMET/C2 - Reprocess: Tipping bucket rain gauge added
DataStreams:twpsmet60sC2.b1
Description:
A tipping bucket rain gauge was added to the TWP.C2 SMET suite of instruments on 20061129. 
Effective 20060926, two new variables (count and rain amount) were added to the end of 
the twpsmet60sC2.b1 datastream.  Between 9/26 and 11/29, the data for these two variables 
are filled with zeros.  Users should not use the data during this period as the zeros are 
not representative of the rain fall at the site.  When reprocessing of this datastream 
occurs these variables will be added for the 19981021-20060926 and data from 
19981021-20061129 will be filled with -9999 (missing).
Measurements:twpsmet60sC2.b1:
  • base time(base_time)


Back To Table of Contents

DQRID : D061121.1
Start DateStart TimeEnd DateEnd Time
11/02/1998211211/06/19982140
07/02/2000200007/04/20000047
02/09/2002230002/11/20022300
01/23/2004110001/27/20041957
05/27/2005114305/29/20052132
Subject:
TWP/MWR/C2 - Missing Data
DataStreams:twpmwrlosC2.b1
Description:
Data are missing and unrecoverable.
Measurements:twpmwrlosC2.b1:
  • 31.4 GHz sky signal(sky31)
  • Noise injection temp at nominal temperature at 31.4 GHz(tnd_nom31)
  • Noise injection temp at 31.4 GHz adjusted to tkbb(tnd31)
  • Mixer kinetic (physical) temperature(tkxc)
  • 23.8 GHz blackbody+noise injection signal(bbn23)
  • Blackbody kinetic temperature(tkbb)
  • lat(lat)
  • Water on Teflon window (1=WET, 0=DRY)(wet_window)
  • lon(lon)
  • 23.8 GHz Blackbody signal(bb23)
  • Temperature correction coefficient at 23.8 GHz(tc23)
  • Sky brightness temperature at 23.8 GHz(tbsky23)
  • 31.4 GHz blackbody(bb31)
  • MWR column precipitable water vapor(vap)
  • 23.8 GHz sky signal(sky23)
  • (tknd)
  • Actual Azimuth(actaz)
  • Ambient temperature(tkair)
  • IR Brightness Temperature(ir_temp)
  • Time offset of tweaks from base_time(time_offset)
  • Actual elevation angle(actel)
  • base time(base_time)
  • Dummy altitude for Zeb(alt)
  • Noise injection temp at nominal temperature at 23.8 GHz(tnd_nom23)
  • 31.4 GHz blac2body+noise injection signal(bbn31)
  • Sky Infra-Red Temperature(sky_ir_temp)
  • Temperature correction coefficient at 31.4 GHz(tc31)
  • Noise injection temp at 23.8 GHz adjusted to tkbb(tnd23)
  • Sky brightness temperature at 31.4 GHz(tbsky31)
  • Averaged total liquid water along LOS path(liq)


Back To Table of Contents



END OF DATA