Data Quality Reports for Session: 112571 User: arunchandr Completed: 06/18/2008


TABLE OF CONTENTS

DQR IDSubjectData Streams Affected
D051216.2SGP/ECOR/E14 - Flux Measurements Incorrectsgp30ecorE14.b1
D070416.4SGP/CO2FLX/C1 - downwelling longwave hemispheric irradiance incorrectsgp30co2flx4mmetC1.b1
D071011.2SGP/CO2FLX/C1 - Reprocess: 4m instruments heightsgp30co2flx4mC1.b1


DQRID : D051216.2
Start DateStart TimeEnd DateEnd Time
11/04/2005133011/17/20051630
12/01/2005193012/13/20051630
01/24/2006150002/13/20061930
05/05/2006210006/13/20061400
07/07/2006193007/14/20061500
Subject:
SGP/ECOR/E14 - Flux Measurements Incorrect
DataStreams:sgp30ecorE14.b1
Description:
The ECOR datastream was corrupted; this happens when the ECOR program produces a 
datastream of the wrong length (i.e., leaves one or more measurements out).

Fluxes and some other measurements are incorrect.

Reprocessing will not correct this problem; the raw data are corrupted.
Measurements:sgp30ecorE14.b1:
  • mean co2 concentration (c)(mean_c)
  • CO2 flux(fc)
  • Water vapor density (q)(mean_q)
  • average temperature (IGRA internal sensor)(temp_irga)
  • average atmospheric pressure (IGRA internal sensor)(atm_pres)
  • h(h)
  • latent heat flux(lv_e)


Back To Table of Contents

DQRID : D070416.4
Start DateStart TimeEnd DateEnd Time
04/28/2004000004/02/20071930
Subject:
SGP/CO2FLX/C1 - downwelling longwave hemispheric irradiance incorrect
DataStreams:sgp30co2flx4mmetC1.b1
Description:
Downwelling longwave radiation measurements (variable "r_down_long_hemisp") are bad due to 
a wiring issue. Users should not use the downwelling longwave hemispheric irradiance 
during this period. The downwelling shortwave and longwave radiation at CF is also available 
from the Broadband Radiometer Station (BRS).
Measurements:sgp30co2flx4mmetC1.b1:
  • downwelling longwave hemispheric irradiance t_rad corrected(r_down_long_hemisp)


Back To Table of Contents

DQRID : D071011.2
Start DateStart TimeEnd DateEnd Time
12/17/2003000010/11/20070000
Subject:
SGP/CO2FLX/C1 - Reprocess: 4m instruments height
DataStreams:sgp30co2flx4mC1.b1
Description:
The height of the 4m instruments is 4.8 m and not 4.65 m as shown in b1 datastream
Measurements:sgp30co2flx4mC1.b1:
  • height of instument from tower base(zm)


Back To Table of Contents



END OF DATA