DQR ID | Subject | Data Streams Affected |
---|---|---|
D011207.3 | SGP/SONDE/C1 - Bad temp (other?) data in 12/3/01:2328 sounding | sgpsondeC1.00, sgpsondewnpnC1.00, sgpsondewnpnC1.a1, sgpsondewnpnC1.b1 |
D011231.1 | SGP/SONDE/C1 - Bad temperature in CF sounding 12/22/01:0527 | sgpsondewnpnC1.a1, sgpsondewnpnC1.b1 |
D011231.2 | SGP/SONDE/C1 - Bad temperature data CF sounding 12/28/01:2326 | sgpsondewnpnC1.a1, sgpsondewnpnC1.b1 |
D060928.3 | SGP/SONDE/C1 - Increased precision for alt, dp, pres, rh, tdry | sgpsondewnpnC1.b1 |
Start Date | Start Time | End Date | End Time |
---|---|---|---|
12/03/2001 | 2328 | 12/04/2001 | 0158 |
Subject: | SGP/SONDE/C1 - Bad temp (other?) data in 12/3/01:2328 sounding |
DataStreams: | sgpsondeC1.00, sgpsondewnpnC1.00, sgpsondewnpnC1.a1, sgpsondewnpnC1.b1 |
Description: | It looks as though the temperature sensor was damaged on launch. The recorded temp goes from 16.4 at the surface to -42.6 at 2 seconds into the flight. The temperature never exceeds -42 though the RH and pressure look reasonable, but probably should be considered questionable. |
Measurements: | sgpsondewnpnC1.00:
sgpsondewnpnC1.a1:
sgpsondewnpnC1.b1:
sgpsondeC1.00:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
12/22/2001 | 0527 | 12/22/2001 | 0659 |
Subject: | SGP/SONDE/C1 - Bad temperature in CF sounding 12/22/01:0527 |
DataStreams: | sgpsondewnpnC1.a1, sgpsondewnpnC1.b1 |
Description: | The temperature data in this sounding look bad after the first value. The temperature series is 11.4, 2.6, -14.3, -32.4 in the first 6 seconds of flight. I don't know why this occurred, but it obviously is incorrect. The pressure and RH data look reasonable. |
Measurements: | sgpsondewnpnC1.a1:
sgpsondewnpnC1.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
12/28/2001 | 2326 | 12/29/2001 | 0045 |
Subject: | SGP/SONDE/C1 - Bad temperature data CF sounding 12/28/01:2326 |
DataStreams: | sgpsondewnpnC1.a1, sgpsondewnpnC1.b1 |
Description: | The temperature data in this sounding are bad from approximately 16 seconds into the flight. The temperature series is 9.9, 10.8, 11.3, 1.5, 11.6, 11.6, 11.6, -32.2 and remains below -30 degC. I don't know why this occurred, but it clearly is incorrect. The pressure data looks OK as does the RH, though the RH data are missing (probably sensor failure) above roughly 3.5 km. |
Measurements: | sgpsondewnpnC1.a1:
sgpsondewnpnC1.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
09/28/2006 | 1728 | 12/31/9999 | 2359 |
Subject: | SGP/SONDE/C1 - Increased precision for alt, dp, pres, rh, tdry |
DataStreams: | sgpsondewnpnC1.b1 |
Description: | The output precision of the following variables was increased 20060928 alt changed from 1m to 0.1m dp changed from 0.1degC to 0.01degC pres changed from 0.1 hPa to 0.01 hPa RH changed from 1%RH to 0.01%RH tdry changed from .1degC to 0.01degC Note that the increase in precision does not necessarily imply an increase in accuracy. Users are cautioned to continue to use their best scientific judgement when using these or any other data. |
Measurements: | sgpsondewnpnC1.b1:
|