DQR ID | Subject | Data Streams Affected |
---|---|---|
D021229.1 | TWP/SONDE/C1 - Broken Temperature Sensor | twpsondewnpnC1.a1, twpsondewnpnC1.b1 |
D021231.2 | TWP/Sonde/C1 - Bad RH Values | twpsondewnpnC1.a1, twpsondewnpnC1.b1 |
D030427.2 | TWP/SONDE/C1 - Questionable RH | twpsondewnpnC1.a1, twpsondewnpnC1.b1 |
D030503.1 | TWP/SONDE/C1 - Bad RH | twpsondewnpnC1.a1, twpsondewnpnC1.b1 |
D030603.3 | TWP/SONDE/C1 - Broken temperature sensor | twpsondewnpnC1.a1, twpsondewnpnC1.b1 |
D040228.1 | TWP/SONDE/C1 - Broken temperature sensor | twpsondewnpnC1.b1 |
D040228.3 | TWP/SONDE/C1 - Bad RH sensors | twpsondewnpnC1.b1 |
D040530.1 | TWP/SONDE/C1 - Bad RH sensor | twpsondewnpnC1.a1, twpsondewnpnC1.b1 |
D040606.1 | TWP/SONDE/C1 - Bad RH at beginning of sounding | twpsondewnpnC1.b1 |
D040627.1 | TWP/SONDE/C1 - Bad RH at beginning of sounding | twpsondewnpnC1.b1 |
D040627.2 | TWP/SONDE/C1 - Bad RH in short interval aloft | twpsondewnpnC1.b1 |
D040711.1 | TWP/SONDE/C1 - Bad RH at beginning of sounding | twpsondewnpnC1.b1 |
D041011.3 | TWP/SONDE/C1 - Bad RH at beginning of sounding | twpsondewnpnC1.b1 |
D050105.1 | TWP/SONDE/C1 - Bad RH at beginning of sounding | twpsondewnpnC1.b1 |
D050201.2 | TWP/SONDE/C1 - Bad RH at beginning of sounding | twpsondewnpnC1.b1 |
D070313.3 | TWP/SONDE/C1 - Surface RH value incorrect | twpsondewnpnC1.b1 |
Start Date | Start Time | End Date | End Time |
---|---|---|---|
09/18/2002 | 2334 | 09/19/2002 | 0111 |
09/21/2002 | 2330 | 09/22/2002 | 0059 |
10/01/2002 | 2349 | 10/02/2002 | 0117 |
10/13/2002 | 1139 | 10/13/2002 | 1303 |
10/18/2002 | 2358 | 10/19/2002 | 0113 |
05/23/2003 | 2330 | 05/24/2003 | 0135 |
06/14/2003 | 2330 | 06/15/2003 | 0147 |
06/22/2003 | 1159 | 06/22/2003 | 1332 |
06/22/2003 | 2349 | 06/23/2003 | 0110 |
06/23/2003 | 1146 | 06/23/2003 | 1323 |
06/25/2003 | 2342 | 06/26/2003 | 0118 |
06/28/2003 | 2330 | 06/29/2003 | 0056 |
06/29/2003 | 1134 | 06/29/2003 | 1312 |
Subject: | TWP/SONDE/C1 - Broken Temperature Sensor |
DataStreams: | twpsondewnpnC1.a1, twpsondewnpnC1.b1 |
Description: | The temperature sensor on these radiosondes broke after launch. All the temperature related data are incorrect. |
Measurements: | twpsondewnpnC1.b1:
twpsondewnpnC1.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
12/21/2002 | 2336 | 12/22/2002 | 0119 |
Subject: | TWP/Sonde/C1 - Bad RH Values |
DataStreams: | twpsondewnpnC1.a1, twpsondewnpnC1.b1 |
Description: | The RH values from the surface to approximately 11.5 km oscillate between reasonable values and zero. This is apparently caused by a failure in the RH sensor heating process. Although the oscillation stops when the heating stops (at temperatures below ~ -45degC) I think the values must be viewed as suspect. |
Measurements: | twpsondewnpnC1.b1:
twpsondewnpnC1.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
04/08/2003 | 2347 | 04/09/2003 | 0003 |
Subject: | TWP/SONDE/C1 - Questionable RH |
DataStreams: | twpsondewnpnC1.a1, twpsondewnpnC1.b1 |
Description: | It appears that the RH sensor heating circuit failed during this portion of the sounding (approximately between 5km and 10km). The RH oscillates rapidly between low (~5 %RH) and not so low (~50 %RH) and the oscillation seems to stop when the temperature is below ~35 degC. According to Vaisala these are symptoms of failure in the ASIC (application specific integrated circuit) that controls the heating. |
Measurements: | twpsondewnpnC1.b1:
twpsondewnpnC1.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
04/29/2003 | 1123 | 04/29/2003 | 1205 |
Subject: | TWP/SONDE/C1 - Bad RH |
DataStreams: | twpsondewnpnC1.a1, twpsondewnpnC1.b1 |
Description: | The RH sensor heating circuit failed on this radiosonde. The RH-related values obtained between 0 and 10000 meters oscillate between near-zero and reasonable ambient values. Above 10000 the RH values are likely correct. |
Measurements: | twpsondewnpnC1.b1:
twpsondewnpnC1.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
05/23/2003 | 2330 | 05/24/2003 | 0135 |
Subject: | TWP/SONDE/C1 - Broken temperature sensor |
DataStreams: | twpsondewnpnC1.a1, twpsondewnpnC1.b1 |
Description: | The temperature sensor on this radiosonde broke after launch. All the temperature-related data are incorrect. |
Measurements: | twpsondewnpnC1.b1:
twpsondewnpnC1.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
02/07/2004 | 2342 | 02/08/2004 | 0115 |
02/09/2004 | 1133 | 02/09/2004 | 1233 |
04/05/2004 | 2332 | 04/06/2004 | 0105 |
04/22/2004 | 1156 | 04/22/2004 | 1317 |
04/24/2004 | 1130 | 04/24/2004 | 1312 |
04/29/2004 | 1137 | 04/29/2004 | 1312 |
04/30/2004 | 2336 | 05/01/2004 | 0112 |
05/03/2004 | 2331 | 05/04/2004 | 0105 |
05/05/2004 | 1135 | 05/05/2004 | 1319 |
05/07/2004 | 1132 | 05/07/2004 | 1315 |
05/11/2004 | 1142 | 05/11/2004 | 1311 |
05/12/2004 | 1145 | 05/12/2004 | 1206 |
05/18/2004 | 1130 | 05/18/2004 | 1321 |
07/10/2004 | 1130 | 07/11/2004 | 1255 |
07/13/2004 | 1139 | 07/13/2004 | 1320 |
07/16/2004 | 2346 | 07/17/2004 | 0107 |
07/22/2004 | 2355 | 07/23/2004 | 0140 |
07/26/2004 | 2341 | 07/27/2004 | 0115 |
08/14/2004 | 2330 | 08/15/2004 | 0104 |
08/22/2004 | 2335 | 08/23/2004 | 0105 |
09/05/2004 | 2340 | 09/06/2004 | 0119 |
09/14/2004 | 2328 | 09/14/2004 | 2329 |
09/17/2004 | 2332 | 09/18/2004 | 0102 |
10/28/2004 | 2336 | 10/29/2004 | 0057 |
11/28/2004 | 2352 | 11/29/2004 | 0044 |
Subject: | TWP/SONDE/C1 - Broken temperature sensor |
DataStreams: | twpsondewnpnC1.b1 |
Description: | The temperature sensor on these radiosondes broke after launch All the temperature-related data are incorrect. |
Measurements: | twpsondewnpnC1.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
02/06/2004 | 2341 | 02/06/2004 | 0130 |
Subject: | TWP/SONDE/C1 - Bad RH sensors |
DataStreams: | twpsondewnpnC1.b1 |
Description: | It appears that the RH sensor heating circuit failed during this portion of the sounding (approximately between 0km and 12km). The RH oscillates rapidly in a 20% range and the oscillation seems to stop when the temperature is below ~45 degC. These are symptoms of failure in the ASIC (application specific integrated circuit) that controls the heating. |
Measurements: | twpsondewnpnC1.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
05/28/2003 | 2330 | 05/29/2003 | 0010 |
Subject: | TWP/SONDE/C1 - Bad RH sensor |
DataStreams: | twpsondewnpnC1.a1, twpsondewnpnC1.b1 |
Description: | It appears that the RH sensor heating circuit failed during this portion of the sounding (approximately between the surface and 11km). The RH oscillates rapidly between low (~0 %RH) and high (~80 %RH) and the oscillation seems to stop when the temperature is below ~40 degC. According to Vaisala these are symptoms of failure in the ASIC (application specific integrated circuit) that controls the heating. |
Measurements: | twpsondewnpnC1.b1:
twpsondewnpnC1.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
06/03/2004 | 1132 | 06/03/2004 | 1212 |
Subject: | TWP/SONDE/C1 - Bad RH at beginning of sounding |
DataStreams: | twpsondewnpnC1.b1 |
Description: | It appears that the RH sensor heating circuit failed during this portion of the sounding (approximately between 0km and 11km). The RH oscillates rapidly between low (~15 %RH) and not so low (~50 %RH) and the oscillation seems to stop when the temperature is below ~40 degC. According to Vaisala these are symptoms of failure in the ASIC (application specific integrated circuit) that controls the heating. |
Measurements: | twpsondewnpnC1.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
06/04/2004 | 0010 | 06/23/2004 | 2330 |
Subject: | TWP/SONDE/C1 - Bad RH at beginning of sounding |
DataStreams: | twpsondewnpnC1.b1 |
Description: | It appears that the RH sensor heating circuit failed during this portion of the sounding (approximately between 0km and 11km). The RH oscillates rapidly between low (~0 %RH) and not so low (~80 %RH) and the oscillation seems to stop when the temperature is below ~40 degC. According to Vaisala these are symptoms of failure in the ASIC (application specific integrated circuit) that controls the heating. |
Measurements: | twpsondewnpnC1.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
06/21/2004 | 0010 | 06/21/2004 | 0011 |
Subject: | TWP/SONDE/C1 - Bad RH in short interval aloft |
DataStreams: | twpsondewnpnC1.b1 |
Description: | It appears that the RH sensor heating circuit on this sonde failed about 31 minutes into the flight. The RH values look reasonable from the surface to approximately 8.25 km at which point they begin to oscillate between 0 and 40%. This behavior stops when the sonde reaches approximately 11.0km when the air temperature drops below -40 degC. The oscillation stops at that point, though the RH remains higher than might be expected even under supersaturated conditions. |
Measurements: | twpsondewnpnC1.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
06/30/2004 | 1130 | 06/30/2004 | 1204 |
Subject: | TWP/SONDE/C1 - Bad RH at beginning of sounding |
DataStreams: | twpsondewnpnC1.b1 |
Description: | It appears that the RH sensor heating circuit failed during this portion of the sounding (approximately between 0km and 11km). The RH oscillates rapidly between low (~2 %RH) and not so low (~90 %RH) and the oscillation seems to stop when the temperature is below ~40 degC. According to Vaisala these are symptoms of failure in the ASIC (application specific integrated circuit) that controls the heating. |
Measurements: | twpsondewnpnC1.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/08/2004 | 1131 | 10/08/2004 | 1200 |
Subject: | TWP/SONDE/C1 - Bad RH at beginning of sounding |
DataStreams: | twpsondewnpnC1.b1 |
Description: | It appears that the RH sensor heating circuit failed during this portion of the sounding (approximately between 0km and 11km). The RH oscillates rapidly between low (~1 %RH) and high (~80 %RH). According to Vaisala these are symptoms of failure in the ASIC (application specific integrated circuit) that controls the heating. |
Measurements: | twpsondewnpnC1.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
12/30/2004 | 2330 | 12/31/2004 | 0108 |
Subject: | TWP/SONDE/C1 - Bad RH at beginning of sounding |
DataStreams: | twpsondewnpnC1.b1 |
Description: | It appears that the RH sensor heating circuit failed during this portion of the sounding (approximately between 0km and 11km). The RH oscillates rapidly between low (~5 %RH) and not so low (~70 %RH) and the oscillation seems to stop when the temperature is below ~40 degC. According to Vaisala these are symptoms of failure in the ASIC (application specific integrated circuit) that controls the heating. |
Measurements: | twpsondewnpnC1.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
01/07/2005 | 2330 | 01/08/2005 | 0102 |
Subject: | TWP/SONDE/C1 - Bad RH at beginning of sounding |
DataStreams: | twpsondewnpnC1.b1 |
Description: | It appears that the RH sensor heating circuit failed during this portion of the sounding (approximately between 0km and 12km). The RH oscillates rapidly between low (~2 %RH) and not so low (~80 %RH) and the oscillation seems to stop when the temperature is below ~40 degC. According to Vaisala these are symptoms of failure in the ASIC (application specific integrated circuit) that controls the heating. |
Measurements: | twpsondewnpnC1.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
03/08/2007 | 0000 | 03/08/2007 | 0001 |
Subject: | TWP/SONDE/C1 - Surface RH value incorrect |
DataStreams: | twpsondewnpnC1.b1 |
Description: | The surface RH value of 77% when the value should have been in the low 60's. It appears the observers did not allow the sonde to equilibrate to ambient conditions before collecting the surface data. This error also caused the dew point to be incorrect. |
Measurements: | twpsondewnpnC1.b1:
|