DQR ID | Subject | Data Streams Affected |
---|---|---|
D000211.4 | SGP/EBBR - EBBR E4 Data Incorrect When Batt. Volt. Under 10.4 V | sgp15ebbrE4.a1, sgp30ebbrE4.a1, sgp5ebbrE4.a0 |
D021113.1 | SGP/EBBR - Incorrect Units for Soil Heat Capacity (cs1, cs2, cs3, cs4, cs5) in 30EBBR Header | sgp30ebbrE12.b1, sgp30ebbrE13.b1, sgp30ebbrE15.b1, sgp30ebbrE18.b1, sgp30ebbrE19.b1, sgp30ebbrE2.b1, sgp30ebbrE20.b1, sgp30ebbrE22.b1, sgp30ebbrE26.b1, sgp30ebbrE4.b1, sgp30ebbrE7.b1, sgp30ebbrE8.b1, sgp30ebbrE9.b1 |
D021113.4 | SGP/EBBR - Incorrect Units for Soil Heat Capacity (cs1, cs2, cs3, cs4, cs5) in 30EBBR Header | sgp30ebbrE12.a1, sgp30ebbrE13.a1, sgp30ebbrE15.a1, sgp30ebbrE20.a1, sgp30ebbrE22.a1, sgp30ebbrE26.a1, sgp30ebbrE4.a1, sgp30ebbrE7.a1, sgp30ebbrE8.a1, sgp30ebbrE9.a1 |
D050719.5 | SGP/EBBR/E4 - Improved EBBR CR10 Program | sgp30ebbrE4.b1 |
Start Date | Start Time | End Date | End Time |
---|---|---|---|
11/08/1998 | 0445 | 09/01/1999 | 1500 |
Subject: | SGP/EBBR - EBBR E4 Data Incorrect When Batt. Volt. Under 10.4 V |
DataStreams: | sgp15ebbrE4.a1, sgp30ebbrE4.a1, sgp5ebbrE4.a0 |
Description: | All data was incorrect when the battery voltage dropped below 10.4 volts. An old battery was the cause of the problem; it had no deep cycle charge capacity. |
Measurements: | sgp5ebbrE4.a0:
sgp15ebbrE4.a1:
sgp30ebbrE4.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
04/01/2001 | 0000 | 06/18/2003 | 2359 |
Subject: | SGP/EBBR - Incorrect Units for Soil Heat Capacity (cs1, cs2, cs3, cs4, cs5) in 30EBBR |
DataStreams: | sgp30ebbrE12.b1, sgp30ebbrE13.b1, sgp30ebbrE15.b1, sgp30ebbrE18.b1, sgp30ebbrE19.b1, sgp30ebbrE2.b1, sgp30ebbrE20.b1, sgp30ebbrE22.b1, sgp30ebbrE26.b1, sgp30ebbrE4.b1, sgp30ebbrE7.b1, sgp30ebbrE8.b1, sgp30ebbrE9.b1 |
Description: | The units for Soil Heat Capacity (cs1, cs2, cs3, cs4, cs5) in the EBBR 30 minute netcdf header have been incorrect from the beginning of processing the data into netcdf files. The correct units are MJ/m^3/C. This does not affect the data quality. |
Measurements: | sgp30ebbrE8.b1:
sgp30ebbrE4.b1:
sgp30ebbrE9.b1:
sgp30ebbrE18.b1:
sgp30ebbrE26.b1:
sgp30ebbrE13.b1:
sgp30ebbrE7.b1:
sgp30ebbrE12.b1:
sgp30ebbrE19.b1:
sgp30ebbrE2.b1:
sgp30ebbrE22.b1:
sgp30ebbrE20.b1:
sgp30ebbrE15.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
12/01/1993 | 0000 | 06/18/2003 | 2359 |
Subject: | SGP/EBBR - Incorrect Units for Soil Heat Capacity (cs1, cs2, cs3, cs4, cs5) in 30EBBR |
DataStreams: | sgp30ebbrE12.a1, sgp30ebbrE13.a1, sgp30ebbrE15.a1, sgp30ebbrE20.a1, sgp30ebbrE22.a1, sgp30ebbrE26.a1, sgp30ebbrE4.a1, sgp30ebbrE7.a1, sgp30ebbrE8.a1, sgp30ebbrE9.a1 |
Description: | The units for Soil Heat Capacity (cs1, cs2, cs3, cs4, cs5) in the EBBR 30 minute netcdf header have been incorrect from the beginning of processing the data into netcdf files. The correct units are MJ/m^3/C. This does not affect the data quality. (NOTE: The actual begin date of some of these data streams is as early as 7/4/93. This DQR applies to all 30m EBBR data.) |
Measurements: | sgp30ebbrE4.a1:
sgp30ebbrE22.a1:
sgp30ebbrE12.a1:
sgp30ebbrE7.a1:
sgp30ebbrE20.a1:
sgp30ebbrE15.a1:
sgp30ebbrE9.a1:
sgp30ebbrE26.a1:
sgp30ebbrE8.a1:
sgp30ebbrE13.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
04/01/2001 | 0000 | 03/23/2005 | 1800 |
Subject: | SGP/EBBR/E4 - Improved EBBR CR10 Program |
DataStreams: | sgp30ebbrE4.b1 |
Description: | Effective 20050323.1800, the EBBR.E4 CR10 program was revised to improve the quality of the primary measurements as follows: 1) An RMS procedure is used to determine max and min limits of acceptable soil heat flow. This is applied to the individual soil sets. Measurements outside the limits are rejected and the measurements within the limits are used to calculate the average soil heat flow. 2) Max and min limits are used to determine incorrect values of net radiation, sensible heat flux (h), latent heat flux (e), and automatic exchange mechanism (AEM) signal. If AEM signal is outside the limits, h and e are set to 999s. If net radiation is outside the limits, h and e are set to 999s. If h or e are outside the limits, h and e are set to 999s. Virtually no incorrect soil measurement will affect the primary measurements of h and e. By setting h and e to 999s, it can be easily seen that the primary variables are incorrect; no other interpretation is possible. Prior to 20050323, the improved CR10 program was NOT in effect. DQRs have been submitted for known instances of incorrect soil measurements which affected the quality of the primary measurements of h and e. Note: the DQR begin date is the begin date of the sgp30ebbrE4.b1 data stream. The earlier version of the CR10 program was also used on previous EBBR datastream names (e.g. sgp30ebbrE4.a1). |
Measurements: | sgp30ebbrE4.b1:
|