DQR ID | Subject | Data Streams Affected |
---|---|---|
D040318.10 | SGP/SMOS/E13 - 6-month Calibration Checks | sgp1440smosE13.b1, sgp1smosE13.b1, sgp30smosE13.b1 |
D070618.2 | SGP/SMOS/E13 - RH sensor failure | sgp1440smosE13.b1, sgp1smosE13.b1, sgp30smosE13.b1 |
D080116.13 | SGP/SMOS/E13 - Wind Data Incorrect Due to Icing | sgp1440smosE13.b1, sgp1smosE13.b1, sgp30smosE13.b1 |
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/16/2003 | 1827 | 10/16/2003 | 1855 |
04/15/2004 | 1958 | 04/15/2004 | 2020 |
10/28/2004 | 1835 | 10/28/2004 | 1855 |
04/15/2005 | 1435 | 04/15/2005 | 1455 |
11/23/2005 | 1940 | 11/23/2005 | 1953 |
05/01/2006 | 1438 | 05/01/2006 | 1545 |
10/13/2006 | 1605 | 10/13/2006 | 1635 |
04/16/2007 | 1414 | 04/16/2007 | 1441 |
10/09/2007 | 1955 | 10/09/2007 | 2025 |
Subject: | SGP/SMOS/E13 - 6-month Calibration Checks |
DataStreams: | sgp1440smosE13.b1, sgp1smosE13.b1, sgp30smosE13.b1 |
Description: | During the time periods specified, the SMOS.E13 tower was lowered for 6-month Calibration Checks. During these times wind data are incorrect and temperature and humidity data may be incorrect. Note, exact times when tower was down or maintenance was being performed is sometimes unknown. Users should use the remaining data from these days with caution. Calibration results are available from the OMIS database at http://www.ops.sgp.arm.gov:591/smos6cal/default.htm To view all 6-month calibration reports leave the date time entry blank. |
Measurements: | sgp1440smosE13.b1:
sgp30smosE13.b1:
sgp1smosE13.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
04/16/2007 | 0000 | 06/18/2007 | 2000 |
Subject: | SGP/SMOS/E13 - RH sensor failure |
DataStreams: | sgp1440smosE13.b1, sgp1smosE13.b1, sgp30smosE13.b1 |
Description: | The T/RH sensor relative humidity data is suspect during this time. Values from this sensor failed the 6-month check and subsequent bi-weekly checks. The RH values were lower by larger than the manufacturer suggested uncertainty of 3%. |
Measurements: | sgp1440smosE13.b1:
sgp30smosE13.b1:
sgp1smosE13.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
12/10/2007 | 2212 | 12/11/2007 | 1945 |
Subject: | SGP/SMOS/E13 - Wind Data Incorrect Due to Icing |
DataStreams: | sgp1440smosE13.b1, sgp1smosE13.b1, sgp30smosE13.b1 |
Description: | An ice storm caused the wind data from the RM Young wind sensor to be incorrect. In many instances it was frozen and unmoving, at times it measured values but those are extremely suspect. |
Measurements: | sgp1440smosE13.b1:
sgp30smosE13.b1:
sgp1smosE13.b1:
|