DQR ID | Subject | Data Streams Affected |
---|---|---|
D070402.1 | SGP/ECOR/E21 - Intermittent incorrect flux measurements | sgp30ecorE21.b1 |
D070514.2 | SGP/ECOR/E14 - IRGA Temperature Incorrect or Missing | sgp30ecorE14.b1 |
D070815.6 | SGP/EBBR/E22 - H and LE Incorrect | sgp15ebbrE22.b1, sgp30ebbrE22.b1 |
D071001.1 | SGP/EBBR/E26 - Sensible and Latent Heat Fluxes Affected by bad temp sensor | sgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1 |
D080428.1 | SGP/ECOR/E24 - Half Hours of Data Missing | sgp30ecorE24.b1 |
Start Date | Start Time | End Date | End Time |
---|---|---|---|
03/01/2007 | 0800 | 08/29/2007 | 1730 |
Subject: | SGP/ECOR/E21 - Intermittent incorrect flux measurements |
DataStreams: | sgp30ecorE21.b1 |
Description: | At various times during the period, the LI-7500 CO2/H2O serial and analog signals from the LI-7500 were missing, but usually not at the same time. When the CO2/H2O serial datastream was missing, the Pressure and Temperature were missing; this did not, in itself, result in incorrect fluxes, as default values for pressure and temperature are automatically used. Fluxes were incorrect when the CO2/H2O analog datastream was missing; these times are identified by the qc checks. |
Measurements: | sgp30ecorE21.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
05/09/2007 | 1300 | 05/19/2007 | 1700 |
Subject: | SGP/ECOR/E14 - IRGA Temperature Incorrect or Missing |
DataStreams: | sgp30ecorE14.b1 |
Description: | The temp_irga was too large 05/09/07 1300 GMT - 05/10/07 2000 GMT. The temp_irga was flat lined at 49.96 C 05/10/07 2030 GMT - 05/17/07 2000 GMT. The temp_irga was missing 05/17/07 2030 GMT - 05/19/07 1700 GMT. |
Measurements: | sgp30ecorE14.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
07/20/2007 | 0630 | 08/01/2007 | 2200 |
Subject: | SGP/EBBR/E22 - H and LE Incorrect |
DataStreams: | sgp15ebbrE22.b1, sgp30ebbrE22.b1 |
Description: | Soil Heat Flow 1 bounced around and went offscale at times, resulting in the EBBR program setting sensible and latent heat fluxes to 9999es. The problem ended during a PM visit, possibly because of routine checks and tightening of leads in terminal strips. |
Measurements: | sgp30ebbrE22.b1:
sgp15ebbrE22.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
09/28/2007 | 0140 | 10/11/2007 | 1730 |
Subject: | SGP/EBBR/E26 - Sensible and Latent Heat Fluxes Affected by bad temp sensor |
DataStreams: | sgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1 |
Description: | The left Thum (temperature of the humidity sensor chamber) measurement was incorrect at times, affecting several measurements, including the sensible and latent heat fluxes. |
Measurements: | sgp15ebbrE26.b1:
sgp5ebbrE26.b1:
sgp30ebbrE26.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/27/2006 | 0530 | 11/08/2007 | 1600 |
Subject: | SGP/ECOR/E24 - Half Hours of Data Missing |
DataStreams: | sgp30ecorE24.b1 |
Description: | Individual half hours of data were missing infrequently because of a UPS problem. The extent of missing data is minimal, with only a few to several half hours missing most months. Data quality of the surrounding data times was not affected. |
Measurements: | sgp30ecorE24.b1:
|