DQR ID | Subject | Data Streams Affected |
---|---|---|
D051118.1 | SGP/PGS/C1 - Suspicious 4m data | sgppgsC1.b1 |
D051118.2 | SGP/PGS/C1 - Suspicious 2m data | sgppgsC1.b1 |
D051118.3 | SGP/PGS/C1 - Suspicious 25m and 60m data | sgppgsC1.b1 |
D051118.4 | SGP/PGS/C1 - Updated files | sgppgsC1.b1 |
Start Date | Start Time | End Date | End Time |
---|---|---|---|
11/24/2004 | 0000 | 08/19/2005 | 0100 |
Subject: | SGP/PGS/C1 - Suspicious 4m data |
DataStreams: | sgppgsC1.b1 |
Description: | KNF pump for 4m height (channel 2) started to leak on November 24, 2004 and sampled air was consequently "contaminated" by indoor air. The pump was replaced on August 19, 2005. |
Measurements: | sgppgsC1.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
07/22/2004 | 0000 | 08/19/2005 | 0100 |
Subject: | SGP/PGS/C1 - Suspicious 2m data |
DataStreams: | sgppgsC1.b1 |
Description: | KNF pump for 2m height (channel 1) started to leak on July 22, 2004 and sampled air was consequently "contaminated" by indoor air. The pump was replaced on August 19, 2005. |
Measurements: | sgppgsC1.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
03/31/2005 | 0000 | 08/19/2005 | 0100 |
Subject: | SGP/PGS/C1 - Suspicious 25m and 60m data |
DataStreams: | sgppgsC1.b1 |
Description: | KNF pumps for 25m and 60m height (channel 3 and channel 4) started to leak on March 31, 2005 and sampled air was consequently "contaminated" by indoor air. The pumps were replaced on August 19, 2005. |
Measurements: | sgppgsC1.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
04/11/2001 | 1156 | 10/31/2005 | 2359 |
Subject: | SGP/PGS/C1 - Updated files |
DataStreams: | sgppgsC1.b1 |
Description: | Dew point temperature (dpt) sensor (Vaisala DMT 142) was added to the system on May 24, 2005 to assess water trapping system efficiency. Consequently, variable "dpt" is filled with missing values (-999.99) prior measurements start date (May 24, 2005). |