DQR ID | Subject | Data Streams Affected |
---|---|---|
D020313.1 | SGP/THWAPS/C1 - THWAPS C1 miscalibrated | sgpthwapsC1.a1, sgpthwapsC1.b1 |
D030917.21 | SGP/THWAPS/B1/B5/B6/C1 - Missing data due to Ice storm and clock problems | sgpthwapsB1.00, sgpthwapsB1.a1, sgpthwapsB1.b1, sgpthwapsB5.00, sgpthwapsB5.a1, sgpthwapsB5.b1, sgpthwapsB6.00, sgpthwapsB6.a1, sgpthwapsB6.b1, sgpthwapsC1.00, sgpthwapsC1.a1, sgpthwapsC1.b1 |
D041123.1 | SGP/THWAPS/C1 - RH Sensor Calibration | sgpthwapsC1.b1 |
D050812.12 | SGP/THWAPS/C1 - Minor bias in saturation vapor pressure | sgpthwapsC1.b1 |
D080116.24 | SGP/THWAPS/C1 - RH Data Incorrect | sgpthwapsC1.b1 |
Start Date | Start Time | End Date | End Time |
---|---|---|---|
03/09/2002 | 0340 | 04/23/2002 | 1418 |
Subject: | SGP/THWAPS/C1 - THWAPS C1 miscalibrated |
DataStreams: | sgpthwapsC1.a1, sgpthwapsC1.b1 |
Description: | Power outages apparently led to the THWAPS HMP233 temperature and RH sensor being replaced at C1. The power went out at 0340 on 3/9 was restored at 0635 and went out again at 2025. The new HMP233 appears to be incorrectly calibrated and all temperature data since its installation are wrong. If I am correct about the nature of the calibration problem, the true average temperature can be recovered from that recorded by a linear conversion, but I don't think its worth the trouble. |
Measurements: | sgpthwapsC1.a1:
sgpthwapsC1.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
03/09/2002 | 2055 | 03/11/2002 | 2005 |
03/13/2002 | 1755 | 03/14/2002 | 1505 |
Subject: | SGP/THWAPS/B1/B5/B6/C1 - Missing data due to Ice storm and clock problems |
DataStreams: | sgpthwapsB1.00, sgpthwapsB1.a1, sgpthwapsB1.b1, sgpthwapsB5.00, sgpthwapsB5.a1, sgpthwapsB5.b1, sgpthwapsB6.00, sgpthwapsB6.a1, sgpthwapsB6.b1, sgpthwapsC1.00, sgpthwapsC1.a1, sgpthwapsC1.b1 |
Description: | Data are missing due to power failures caused by an ice storm and resulting system/instrument clock problems. |
Measurements: | sgpthwapsC1.a1:
sgpthwapsB1.b1:
sgpthwapsB5.00:
sgpthwapsB6.00:
sgpthwapsB6.a1:
sgpthwapsB5.b1:
sgpthwapsC1.00:
sgpthwapsB1.a1:
sgpthwapsC1.b1:
sgpthwapsB1.00:
sgpthwapsB6.b1:
sgpthwapsB5.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
11/16/2004 | 2135 | 11/29/2004 | 1930 |
Subject: | SGP/THWAPS/C1 - RH Sensor Calibration |
DataStreams: | sgpthwapsC1.b1 |
Description: | The analog output for the T/RH probe was incorrectly calibrated. This caused excessively high readings of RH. |
Measurements: | sgpthwapsC1.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
09/21/1999 | 0000 | 08/10/2005 | 1445 |
Subject: | SGP/THWAPS/C1 - Minor bias in saturation vapor pressure |
DataStreams: | sgpthwapsC1.b1 |
Description: | The saturation vapor correction when temps are below 0C contained an error in the multiplier. The incorrect multiplier only equates to an error of 0.01 kPa which is less than the stated uncertainty of the measurement (+/- 0.035 kPa). |
Measurements: | sgpthwapsC1.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
12/22/2007 | 1750 | 12/22/2007 | 2130 |
Subject: | SGP/THWAPS/C1 - RH Data Incorrect |
DataStreams: | sgpthwapsC1.b1 |
Description: | The RH data was incorrect during the times listed. Reason unknown. The sensor recovered on its own. |
Measurements: | sgpthwapsC1.b1:
|