Data Quality Reports for Session: 116268 User: yang1jing1 Completed: 12/08/2008


TABLE OF CONTENTS

DQR IDSubjectData Streams Affected
D040706.3SGP/EBBR/E27 - Loose Tair Left Connectionssgp15ebbrE27.b1, sgp30ebbrE27.b1, sgp5ebbrE27.b1
D040813.8SGP/EBBR/E7 - Pressure Too Highsgp15ebbrE7.b1, sgp30ebbrE7.b1, sgp5ebbrE7.b1
D050211.2SGP/EBBR/E27 - Soil Moisture #5 Incorrectsgp30ebbrE27.b1
D050413.6SGP/EBBR/E27 - SM2 Coefficients Incorectsgp15ebbrE27.b1, sgp30ebbrE27.b1
D050719.16SGP/EBBR/E27 - Improved EBBR CR10 Programsgp30ebbrE27.b1
D050719.5SGP/EBBR/E4 - Improved EBBR CR10 Programsgp30ebbrE4.b1
D050719.6SGP/EBBR/E7 - Improved EBBR CR10 Programsgp30ebbrE7.b1
D050719.7SGP/EBBR/E8 - Improved EBBR CR10 Programsgp30ebbrE8.b1
D050719.8SGP/EBBR/E9 - Improved EBBR CR10 Programsgp30ebbrE9.b1
D051112.10SGP/EBBR/E27 - metadata correctionssgp15ebbrE27.b1, sgp30ebbrE27.b1, sgp5ebbrE27.b1
D051112.3SGP/EBBR/E4 - metadata correctionssgp15ebbrE4.b1, sgp30ebbrE4.b1, sgp5ebbrE4.b1
D051112.4SGP/EBBR/E7 - metadata correctionssgp15ebbrE7.b1, sgp30ebbrE7.b1, sgp5ebbrE7.b1
D051112.5SGP/EBBR/E8 - metadata correctionssgp15ebbrE8.b1, sgp30ebbrE8.b1, sgp5ebbrE8.b1
D051112.6SGP/EBBR/E9 - metadata correctionssgp15ebbrE9.b1, sgp30ebbrE9.b1, sgp5ebbrE9.b1


DQRID : D040706.3
Start DateStart TimeEnd DateEnd Time
06/10/2004060007/21/20041725
Subject:
SGP/EBBR/E27 - Loose Tair Left Connections
DataStreams:sgp15ebbrE27.b1, sgp30ebbrE27.b1, sgp5ebbrE27.b1
Description:
Tair left dropped out at times. When this occurred, the sensible and latent heat fluxes 
are incorrect.

Tightening of the electronic connections to the datalogging equipment
appears to have solved the problem.
Measurements:sgp5ebbrE27.b1:
  • bottom air temperature(tair_bot)
  • top air temperature(tair_top)

sgp30ebbrE27.b1:
  • bottom air temperature(tair_bot)
  • h(h)
  • latent heat flux(e)
  • top air temperature(tair_top)
  • ratio of sensible/latent heat fluxes (Bowen ratio)(bowen)

sgp15ebbrE27.b1:
  • Left air temperature(tair_l)


Back To Table of Contents

DQRID : D040813.8
Start DateStart TimeEnd DateEnd Time
08/10/2004192508/24/20041820
Subject:
SGP/EBBR/E7 - Pressure Too High
DataStreams:sgp15ebbrE7.b1, sgp30ebbrE7.b1, sgp5ebbrE7.b1
Description:
When data collection resumed after a missing period, the barometer pressure
had become very high, 102 kPa, which was not correct.  This condition resulted
from an incorrect calibration being used. Sensible heat flux was overestimated 
by about 4% and latent heat flux underestimated by about 4% because of the 
high pressure readings.
Measurements:sgp15ebbrE7.b1:
  • Atmospheric pressure(mv_pres)

sgp30ebbrE7.b1:
  • ratio of sensible/latent heat fluxes (Bowen ratio)(bowen)
  • Retrieved pressure profile(pres)
  • h(h)
  • latent heat flux(e)

sgp5ebbrE7.b1:
  • Retrieved pressure profile(pres)


Back To Table of Contents

DQRID : D050211.2
Start DateStart TimeEnd DateEnd Time
09/15/2004160003/07/20052100
Subject:
SGP/EBBR/E27 - Soil Moisture #5 Incorrect
DataStreams:sgp30ebbrE27.b1
Description:
The wrong CR10 program loaded from the storage module on 9/15/04.  During the previous 
change of program, an attempt was made to store the new program in the storage module; site 
ops techs did not notice that this attempt failed, leaving the old program in the storage 
module.  When power was cyled on 9/15/04, the old program with flat sm5 coefficients 
loaded into the CR10.  The "flat" coefficients resulted in the sm5 soil moisture hovering 
around 30%.

15 minute raw sm5 resistances were correct.

Average soil heat flow, sensible heat flux, and latent heat flux were not
significantly affected and so are not included in the list of incorrect measurements.
Measurements:sgp30ebbrE27.b1:
  • volumetric soil moisture, site 5(sm5)


Back To Table of Contents

DQRID : D050413.6
Start DateStart TimeEnd DateEnd Time
03/04/2004164503/02/20051600
Subject:
SGP/EBBR/E27 - SM2 Coefficients Incorect
DataStreams:sgp15ebbrE27.b1, sgp30ebbrE27.b1
Description:
Soil Moisture #2 coefficients in the CR10 datalogger program were incorrect during the 
time
that an old program version was installed.
Measurements:sgp30ebbrE27.b1:
  • 5 cm soil heat flow corrected for soil moisture content, site 2(c_shf2)
  • volumetric soil moisture, site 2(sm2)
  • Soil heat capacity 2(cs2)
  • soil heat flow, site 2(g2)
  • 0-5 cm change in soil heat storage with time, site 2(ces2)

sgp15ebbrE27.b1:
  • Soil moisture 2(r_sm2)


Back To Table of Contents

DQRID : D050719.16
Start DateStart TimeEnd DateEnd Time
05/07/2003000003/30/20051730
Subject:
SGP/EBBR/E27 - Improved EBBR CR10 Program
DataStreams:sgp30ebbrE27.b1
Description:
Effective 20050330.1730, the EBBR.E27 CR10 program was revised to improve 
the quality of the primary measurements as follows:
   
1) An RMS procedure is used to determine max and min limits of acceptable
soil heat flow.  This is applied to the individual soil sets.  Measurements
outside the limits are rejected and the measurements within the limits are
used to calculate the average soil heat flow.
   
2) Max and min limits are used to determine incorrect values of net
radiation, sensible heat flux (h), latent heat flux (e), and automatic
exchange mechanism (AEM) signal.  If AEM signal is outside the limits, h 
and e are set to 999s.  If net radiation is outside the limits, h and e are 
set to 999s. If h or e are outside the limits, h and e are set to 999s.
   
Virtually no incorrect soil measurement will affect the primary 
measurements of h and e.
   
By setting h and e to 999s, it can be easily seen that the primary 
variables are incorrect; no other interpretation is possible.
   
Prior to 20050330, the improved CR10 program was NOT in effect.  DQRs have
been submitted for known instances of incorrect soil measurements which
affected the quality of the primary measurements of h and e.
   
Note: the DQR begin date is the begin date of the sgp30ebbrE27.b1 data
stream.  The earlier version of the CR10 program was also used on previous
EBBR datastream names (e.g. sgp30ebbrE27.a1).
Measurements:sgp30ebbrE27.b1:
  • average surface soil heat flow(ave_shf)
  • h(h)
  • latent heat flux(e)


Back To Table of Contents

DQRID : D050719.5
Start DateStart TimeEnd DateEnd Time
04/01/2001000003/23/20051800
Subject:
SGP/EBBR/E4 - Improved EBBR CR10 Program
DataStreams:sgp30ebbrE4.b1
Description:
Effective 20050323.1800, the EBBR.E4 CR10 program was revised to improve the quality of 
the primary measurements as follows:
   
1) An RMS procedure is used to determine max and min limits of acceptable
soil heat flow.  This is applied to the individual soil sets.  Measurements
outside the limits are rejected and the measurements within the limits are
used to calculate the average soil heat flow.
   
2) Max and min limits are used to determine incorrect values of net
radiation, sensible heat flux (h), latent heat flux (e), and automatic
exchange mechanism (AEM) signal.  If AEM signal is outside the limits, h and e are set to 
999s.  If net radiation is outside the limits, h and e are set to 999s. If h or e are 
outside the limits, h and e are set to 999s.
   
Virtually no incorrect soil measurement will affect the primary measurements of h and e.
   
By setting h and e to 999s, it can be easily seen that the primary variables are 
incorrect; no other interpretation is possible.
   
Prior to 20050323, the improved CR10 program was NOT in effect.  DQRs have
been submitted for known instances of incorrect soil measurements which
affected the quality of the primary measurements of h and e.
   
Note: the DQR begin date is the begin date of the sgp30ebbrE4.b1 data
stream.  The earlier version of the CR10 program was also used on previous
EBBR datastream names (e.g. sgp30ebbrE4.a1).
Measurements:sgp30ebbrE4.b1:
  • h(h)
  • average surface soil heat flow(ave_shf)
  • latent heat flux(e)


Back To Table of Contents

DQRID : D050719.6
Start DateStart TimeEnd DateEnd Time
04/01/2001000003/22/20051900
Subject:
SGP/EBBR/E7 - Improved EBBR CR10 Program
DataStreams:sgp30ebbrE7.b1
Description:
Effective 20050322.1900, the EBBR.E7 CR10 program was revised to improve 
the quality of the primary measurements as follows:
   
1) An RMS procedure is used to determine max and min limits of acceptable
soil heat flow.  This is applied to the individual soil sets.  Measurements
outside the limits are rejected and the measurements within the limits are
used to calculate the average soil heat flow.
   
2) Max and min limits are used to determine incorrect values of net
radiation, sensible heat flux (h), latent heat flux (e), and automatic
exchange mechanism (AEM) signal.  If AEM signal is outside the limits, h 
and e are set to 999s.  If net radiation is outside the limits, h and e are 
set to 999s. If h or e are outside the limits, h and e are set to 999s.
   
Virtually no incorrect soil measurement will affect the primary 
measurements of h and e.
   
By setting h and e to 999s, it can be easily seen that the primary 
variables are incorrect; no other interpretation is possible.
   
Prior to 20050322, the improved CR10 program was NOT in effect.  DQRs have
been submitted for known instances of incorrect soil measurements which
affected the quality of the primary measurements of h and e.
   
Note: the DQR begin date is the begin date of the sgp30ebbrE7.b1 data
stream.  The earlier version of the CR10 program was also used on previous
EBBR datastream names (e.g. sgp30ebbrE7.a1).
Measurements:sgp30ebbrE7.b1:
  • average surface soil heat flow(ave_shf)
  • h(h)
  • latent heat flux(e)


Back To Table of Contents

DQRID : D050719.7
Start DateStart TimeEnd DateEnd Time
04/01/2001000003/22/20051730
Subject:
SGP/EBBR/E8 - Improved EBBR CR10 Program
DataStreams:sgp30ebbrE8.b1
Description:
Effective 20050322.1730, the EBBR.E8 CR10 program was revised to improve 
the quality of the primary measurements as follows:
   
1) An RMS procedure is used to determine max and min limits of acceptable
soil heat flow.  This is applied to the individual soil sets.  Measurements
outside the limits are rejected and the measurements within the limits are
used to calculate the average soil heat flow.
   
2) Max and min limits are used to determine incorrect values of net
radiation, sensible heat flux (h), latent heat flux (e), and automatic
exchange mechanism (AEM) signal.  If AEM signal is outside the limits, h 
and e are set to 999s.  If net radiation is outside the limits, h and e are 
set to 999s. If h or e are outside the limits, h and e are set to 999s.
   
Virtually no incorrect soil measurement will affect the primary 
measurements of h and e.
   
By setting h and e to 999s, it can be easily seen that the primary 
variables are incorrect; no other interpretation is possible.
   
Prior to 20050322, the improved CR10 program was NOT in effect.  DQRs have
been submitted for known instances of incorrect soil measurements which
affected the quality of the primary measurements of h and e.
   
Note: the DQR begin date is the begin date of the sgp30ebbrE8.b1 data
stream.  The earlier version of the CR10 program was also used on previous
EBBR datastream names (e.g. sgp30ebbrE8.a1).
Measurements:sgp30ebbrE8.b1:
  • average surface soil heat flow(ave_shf)
  • latent heat flux(e)
  • h(h)


Back To Table of Contents

DQRID : D050719.8
Start DateStart TimeEnd DateEnd Time
04/01/2001000003/22/20051600
Subject:
SGP/EBBR/E9 - Improved EBBR CR10 Program
DataStreams:sgp30ebbrE9.b1
Description:
Effective 20050322.1600, the EBBR.E9 CR10 program was revised to improve 
the quality of the primary measurements as follows:
   
1) An RMS procedure is used to determine max and min limits of acceptable
soil heat flow.  This is applied to the individual soil sets.  Measurements
outside the limits are rejected and the measurements within the limits are
used to calculate the average soil heat flow.
   
2) Max and min limits are used to determine incorrect values of net
radiation, sensible heat flux (h), latent heat flux (e), and automatic
exchange mechanism (AEM) signal.  If AEM signal is outside the limits, h 
and e are set to 999s.  If net radiation is outside the limits, h and e are 
set to 999s. If h or e are outside the limits, h and e are set to 999s.
   
Virtually no incorrect soil measurement will affect the primary 
measurements of h and e.
   
By setting h and e to 999s, it can be easily seen that the primary 
variables are incorrect; no other interpretation is possible.
   
Prior to 20050322, the improved CR10 program was NOT in effect.  DQRs have
been submitted for known instances of incorrect soil measurements which
affected the quality of the primary measurements of h and e.
   
Note: the DQR begin date is the begin date of the sgp30ebbrE9.b1 data
stream.  The earlier version of the CR10 program was also used on previous
EBBR datastream names (e.g. sgp30ebbrE9.a1).
Measurements:sgp30ebbrE9.b1:
  • latent heat flux(e)
  • average surface soil heat flow(ave_shf)
  • h(h)


Back To Table of Contents

DQRID : D051112.10
Start DateStart TimeEnd DateEnd Time
10/13/2003000008/16/20052359
Subject:
SGP/EBBR/E27 - metadata corrections
DataStreams:sgp15ebbrE27.b1, sgp30ebbrE27.b1, sgp5ebbrE27.b1
Description:
On 20050816, a series of metadata corrections and additions were completed.  These 
metadata changes apply to all EBBR.E27 data collected by ARM back to the installation of the 
instrument in May 2003. Please see the current metadata for correct information.  These 
changes do not affect data values or quality.	

The changes are summarized below:
1) Update of "sensor location" information
2) Addition of installation dates for the systems
3) Correction of soil moisture units (from "by volume" to "gravimetric")
Measurements:sgp30ebbrE27.b1:
  • base time(base_time)

sgp5ebbrE27.b1:
  • base time(base_time)

sgp15ebbrE27.b1:
  • base time(base_time)


Back To Table of Contents

DQRID : D051112.3
Start DateStart TimeEnd DateEnd Time
10/14/2003000008/16/20052359
Subject:
SGP/EBBR/E4 - metadata corrections
DataStreams:sgp15ebbrE4.b1, sgp30ebbrE4.b1, sgp5ebbrE4.b1
Description:
On 20050817, a series of metadata corrections and additions were completed.  These 
metadata changes apply to all EBBR.E4 data collected by ARM back to the installation of the 
instrument in April 1993. Please see the current metadata for correct information.  These 
changes do not affect data values or quality.	

The changes are summarized below:
1) Update of "sensor location" information
2) Addition of installation dates for the systems
3) Correction of soil moisture units (from "by volume" to "gravimetric")
Measurements:sgp5ebbrE4.b1:
  • base time(base_time)

sgp30ebbrE4.b1:
  • base time(base_time)

sgp15ebbrE4.b1:
  • base time(base_time)


Back To Table of Contents

DQRID : D051112.4
Start DateStart TimeEnd DateEnd Time
10/13/2003000007/22/20052359
Subject:
SGP/EBBR/E7 - metadata corrections
DataStreams:sgp15ebbrE7.b1, sgp30ebbrE7.b1, sgp5ebbrE7.b1
Description:
On 20050723, a series of metadata corrections and additions were completed.  These 
metadata changes apply to all EBBR.E7 data collected by ARM back to the installation of the 
instrument in May 1993. Please see the current metadata for correct information.  These 
changes do not affect data values or quality.	

The changes are summarized below:
1) Update of "sensor location" information
2) Addition of installation dates for the systems
3) Correction of soil moisture units (from "by volume" to "gravimetric")
Measurements:sgp5ebbrE7.b1:
  • base time(base_time)

sgp30ebbrE7.b1:
  • base time(base_time)

sgp15ebbrE7.b1:
  • base time(base_time)


Back To Table of Contents

DQRID : D051112.5
Start DateStart TimeEnd DateEnd Time
10/13/2003000007/22/20052359
Subject:
SGP/EBBR/E8 - metadata corrections
DataStreams:sgp15ebbrE8.b1, sgp30ebbrE8.b1, sgp5ebbrE8.b1
Description:
On 20050723, a series of metadata corrections and additions were completed.  These 
metadata changes apply to all EBBR.E8 data collected by ARM back to the installation of the 
instrument in December 1992. Please see the current metadata for correct information.  These 
changes do not affect data values or quality.	

The changes are summarized below:
1) Update of "sensor location" information
2) Addition of installation dates for the systems
3) Correction of soil moisture units (from "by volume" to "gravimetric")
Measurements:sgp30ebbrE8.b1:
  • base time(base_time)

sgp5ebbrE8.b1:
  • base time(base_time)

sgp15ebbrE8.b1:
  • base time(base_time)


Back To Table of Contents

DQRID : D051112.6
Start DateStart TimeEnd DateEnd Time
10/13/2003000004/19/20052359
Subject:
SGP/EBBR/E9 - metadata corrections
DataStreams:sgp15ebbrE9.b1, sgp30ebbrE9.b1, sgp5ebbrE9.b1
Description:
On 20050420, a series of metadata corrections and additions were completed.  These 
metadata changes apply to all EBBR.E9 data collected by ARM back to the installation of the 
instrument in December 1992. Please see the current metadata for correct information.  These 
changes do not affect data values or quality.	

The changes are summarized below:
1) Update of "sensor location" information
2) Addition of installation dates for the systems
3) Correction of soil moisture units (from "by volume" to "gravimetric")
Measurements:sgp15ebbrE9.b1:
  • base time(base_time)

sgp5ebbrE9.b1:
  • base time(base_time)

sgp30ebbrE9.b1:
  • base time(base_time)


Back To Table of Contents



END OF DATA