Data Quality Reports for Session: 118957 User: dmfoper Completed: 04/17/2009


TABLE OF CONTENTS

DQR IDSubjectData Streams Affected
D011127.23SGP EBBR E7 - E7 EBBR Data Incorrect During 6 Month Checkssgp15ebbrE7.a1, sgp15ebbrE7.b1, sgp30ebbrE7.a1, sgp30ebbrE7.b1, sgp5ebbrE7.a1
D011129.6SGP EBBR E7 - E7 EBBR AEM Position Caused Incorrect Datasgp15ebbrE7.a1, sgp15ebbrE7.b1, sgp30ebbrE7.a1, sgp30ebbrE7.b1, sgp5ebbrE7.a1
D011129.7SGP EBBR E7 - E7 EBBR All Data Incorrectsgp15ebbrE7.a1, sgp15ebbrE7.b1, sgp30ebbrE7.a1, sgp30ebbrE7.b1, sgp5ebbrE7.a1
D011129.8SGP EBBR E7 - E7 EBBR Data Incorrect After Recalibrationsgp15ebbrE7.a1, sgp15ebbrE7.b1, sgp30ebbrE7.a1, sgp30ebbrE7.b1
D011129.9SGP EBBR E7 - E7 EBBR Data Incorrect After Missing Data Periodsgp15ebbrE7.a1, sgp15ebbrE7.b1, sgp30ebbrE7.a1, sgp30ebbrE7.b1
D020716.26SGP/EBBR/E7 - Measurements Zerosgp15ebbrE7.a1, sgp15ebbrE7.b1, sgp30ebbrE7.a1, sgp30ebbrE7.b1, sgp5ebbrE7.00,
sgp5ebbrE7.a1
D020716.27SGP/EBBR/E7 - AEM Hungsgp15ebbrE7.a1, sgp15ebbrE7.b1, sgp30ebbrE7.a1, sgp30ebbrE7.b1, sgp5ebbrE7.a1
D020716.28SGP/EBBR/E7 - Wind Speed Incorrectsgp15ebbrE7.a1, sgp15ebbrE7.b1, sgp30ebbrE7.a1, sgp30ebbrE7.b1, sgp5ebbrE7.a1
D020716.8SGP/EBBR/E7 - 6 Month Checkssgp15ebbrE7.a1, sgp15ebbrE7.b1, sgp30ebbrE7.a1, sgp30ebbrE7.b1, sgp5ebbrE7.a1
D021113.1SGP/EBBR - Incorrect Units for Soil Heat Capacity (cs1, cs2, cs3, cs4, cs5) in 30EBBR
Header
sgp30ebbrE12.b1, sgp30ebbrE13.b1, sgp30ebbrE15.b1, sgp30ebbrE18.b1, sgp30ebbrE19.b1,
sgp30ebbrE2.b1, sgp30ebbrE20.b1, sgp30ebbrE22.b1, sgp30ebbrE26.b1, sgp30ebbrE4.b1,
sgp30ebbrE7.b1, sgp30ebbrE8.b1, sgp30ebbrE9.b1
D030110.30SGP/EBBR/E7 - Data Incorrect during 6 month checkssgp15ebbrE7.a1, sgp15ebbrE7.b1, sgp30ebbrE7.a1, sgp30ebbrE7.b1, sgp5ebbrE7.a1
D030113.1SGP/EBBR/E7 - Wind speed incorrectsgp15ebbrE7.a1, sgp15ebbrE7.b1, sgp30ebbrE7.a1, sgp30ebbrE7.b1, sgp5ebbrE7.a1
D030113.3SGP/EBBR/E7 - CES data incorrectsgp30ebbrE7.a1, sgp30ebbrE7.b1
D030113.4SGP/EBBR/E7 - REPROCESS: Soil Heat Flow #2 Incorrectsgp30ebbrE7.a1, sgp30ebbrE7.b1
D030113.5SGP/EBBR/E7 - Change In Energy Storage Calculations Incorrectsgp30ebbrE7.a1, sgp30ebbrE7.b1
D030113.6SGP/EBBR/E7 - REPROCESS: Soil Heat Flow #5 too lowsgp30ebbrE7.a1, sgp30ebbrE7.b1
D030113.7SGP/EBBR/E7 - AEM Problemssgp15ebbrE7.a1, sgp15ebbrE7.b1, sgp30ebbrE7.a1, sgp30ebbrE7.b1, sgp5ebbrE7.a1
D030113.8SGP/EBBR/E7 - T/RH Ventilator Fans Stoppedsgp15ebbrE7.a1, sgp15ebbrE7.b1, sgp30ebbrE7.a1, sgp30ebbrE7.b1, sgp5ebbrE7.a1
D030114.2SGP/EBBR/E7 - Data Reported as Zero following Logger Replacementsgp15ebbrE7.a1, sgp15ebbrE7.b1, sgp30ebbrE7.a1, sgp30ebbrE7.b1, sgp5ebbrE7.a1
D030712.13SGP/EBBR/E7 - 6 Month Checkssgp15ebbrE7.a1, sgp15ebbrE7.b1, sgp30ebbrE7.a1, sgp30ebbrE7.b1, sgp5ebbrE7.a1
D030712.9SGP/EBBR/E7 - AEM Hung Inbetween Home Positionsgp15ebbrE7.a1, sgp15ebbrE7.b1, sgp30ebbrE7.a1, sgp30ebbrE7.b1, sgp5ebbrE7.a1
D031211.6SGP/EBBR/E7 - Pressure Sensor Data Incorrectsgp15ebbrE7.b1, sgp30ebbrE7.b1, sgp5ebbrE7.a1
D050719.6SGP/EBBR/E7 - Improved EBBR CR10 Programsgp30ebbrE7.b1


DQRID : D011127.23
Start DateStart TimeEnd DateEnd Time
05/08/2001180005/08/20011901
11/25/2001143511/25/20011601
Subject:
SGP EBBR E7 - E7 EBBR Data Incorrect During 6 Month Checks
DataStreams:sgp15ebbrE7.a1, sgp15ebbrE7.b1, sgp30ebbrE7.a1, sgp30ebbrE7.b1, sgp5ebbrE7.a1
Description:
The data was incorrect during the 6 month checks.
Measurements:sgp5ebbrE7.a1:
  • Temperature of the top humidity chamber(thum_top)
  • Reference Thermistor Temperature(tref)
  • Top humidity(hum_top)
  • Retrieved pressure profile(pres)
  • vector wind speed(res_ws)
  • standard deviation of wind direction (sigma theta)(sigma_wd)
  • net radiation(q)
  • Bottom humidity(hum_bot)
  • bottom vapor pressure(vp_bot)
  • Temperature of bottom humidity sensor chamber(thum_bot)
  • wind direction (relative to true north)(wind_d)
  • top vapor pressure(vp_top)
  • top air temperature(tair_top)
  • scalar wind speed(wind_s)
  • bottom air temperature(tair_bot)

sgp30ebbrE7.a1:
  • 0-5 cm change in soil heat storage with time, site 3(ces3)
  • wind direction (relative to true north)(wind_d)
  • soil heat flow, site 2(g2)
  • average surface soil heat flow(ave_shf)
  • top air temperature(tair_top)
  • vector wind speed(res_ws)
  • volumetric soil moisture, site 5(sm5)
  • 0-5 cm change in soil heat storage with time, site 2(ces2)
  • 0-5 cm integrated soil temperature, site 2(ts2)
  • bottom air temperature(tair_bot)
  • volumetric soil moisture, site 4(sm4)
  • 0-5 cm integrated soil temperature, site 5(ts5)
  • standard deviation of wind direction (sigma theta)(sigma_wd)
  • Temperature of bottom humidity sensor chamber(thum_bot)
  • 0-5 cm integrated soil temperature, site 4(ts4)
  • volumetric soil moisture, site 2(sm2)
  • Soil heat capacity 2(cs2)
  • 5 cm soil heat flow corrected for soil moisture content, site 1(c_shf1)
  • volumetric soil moisture, site 1(sm1)
  • latent heat flux(e)
  • 0-5 cm change in soil heat storage with time, site 4(ces4)
  • soil heat flow, site 4(g4)
  • soil heat flow, site 3(g3)
  • Temperature of the top humidity chamber(thum_top)
  • 5 cm soil heat flow corrected for soil moisture content, site 2(c_shf2)
  • Soil heat capacity 5(cs5)
  • 5 cm soil heat flow corrected for soil moisture content, site 5(c_shf5)
  • 0-5 cm change in soil heat storage with time, site 5(ces5)
  • Soil heat capacity 3(cs3)
  • Retrieved pressure profile(pres)
  • Reference Thermistor Temperature(tref)
  • Soil heat capacity 1(cs1)
  • 5 cm soil heat flow, site 5(shf5)
  • 5 cm soil heat flow corrected for soil moisture content, site 4(c_shf4)
  • net radiation(q)
  • Soil heat capacity 4(cs4)
  • 5 cm soil heat flow, site 1(shf1)
  • ratio of sensible/latent heat fluxes (Bowen ratio)(bowen)
  • bottom vapor pressure(vp_bot)
  • 5 cm soil heat flow, site 4(shf4)
  • h(h)
  • 5 cm soil heat flow corrected for soil moisture content, site 3(c_shf3)
  • soil heat flow, site 1(g1)
  • Top humidity(hum_top)
  • soil heat flow, site 5(g5)
  • top vapor pressure(vp_top)
  • scalar wind speed(wind_s)
  • 5 cm soil heat flow, site 2(shf2)
  • 0-5 cm integrated soil temperature, site 3(ts3)
  • 5 cm soil heat flow, site 3(shf3)
  • 0-5 cm change in soil heat storage with time, site 2(ces1)
  • Bottom humidity(hum_bot)
  • volumetric soil moisture, site 3(sm3)
  • 0-5 cm integrated soil temperature, site 2(ts1)

sgp15ebbrE7.a1:
  • Soil moisture 5(r_sm5)
  • Atmospheric pressure(mv_pres)
  • Soil temperature 5(rr_ts5)
  • Left relative humidity(mv_hum_l)
  • Soil heat flow 5(mv_hft5)
  • Soil moisture 2(r_sm2)
  • Soil temperature 4(rr_ts4)
  • Soil heat flow 4(mv_hft4)
  • Soil moisture 3(r_sm3)
  • Wind direction (relative to true north)(mv_wind_d)
  • Left air temperature(tair_l)
  • Soil moisture 2(rr_sm2)
  • Right air temperature(tair_r)
  • Soil moisture 5(rr_sm5)
  • Soil moisture 1(r_sm1)
  • Soil moisture 3(rr_sm3)
  • Soil heat flow 1(mv_hft1)
  • Soil moisture 4(r_sm4)
  • Temperature of left humidity sensor chamber(rr_thum_l)
  • Temperature of right humidity sensor chamber(rr_thum_r)
  • Soil moisture 4(rr_sm4)
  • Right relative humidity(mv_hum_r)
  • Soil moisture 1(rr_sm1)
  • Soil temperature 2(rr_ts2)
  • Soil temperature 3(rr_ts3)
  • Soil heat flow 2(mv_hft2)
  • Soil heat flow 3(mv_hft3)
  • Net radiation(mv_q)
  • Soil temperature 1(rr_ts1)
  • Reference temperature(rr_tref)
  • scalar wind speed(wind_s)

sgp15ebbrE7.b1:
  • soil_moisture_1_rr
  • soil_heat_flow_1_mv
  • soil_temp_4_rr
  • soil_heat_flow_4_mv
  • soil_moisture_3_rr
  • soil_temp_5_rr
  • atmos_pressure_mv
  • rh_right_mv
  • soil_temp_1_rr
  • net_radiation_mv
  • soil_heat_flow_3_mv
  • soil_heat_flow_2_mv
  • soil_moisture_4_rr
  • temp_reference_rr
  • soil_moisture_5_rr
  • temp_air_right
  • temp_trh_right_rr
  • wdir_vec_mean_mv
  • temp_air_left
  • soil_temp_3_rr
  • wspd_arith_mean
  • temp_trh_left_rr
  • home_signal
  • soil_heat_flow_5_mv
  • soil_temp_2_rr
  • rh_left_mv
  • soil_moisture_2_rr

sgp30ebbrE7.b1:
  • corr_soil_heat_flow_5
  • soil_heat_capacity_5
  • soil_moisture_2
  • soil_heat_capacity_4
  • wspd_arith_mean
  • surface_soil_heat_flux_1
  • energy_storage_change_4
  • vapor_pressure_top
  • surface_soil_heat_flux_2
  • soil_moisture_1
  • soil_moisture_3
  • corr_soil_heat_flow_4
  • surface_soil_heat_flux_avg
  • corr_soil_heat_flow_3
  • soil_moisture_5
  • energy_storage_change_5
  • soil_heat_capacity_1
  • vapor_pressure_bottom
  • temp_trh_top
  • sensible_heat_flux
  • soil_moisture_4
  • temp_reference
  • bowen_ratio
  • soil_heat_flow_1
  • Barometric Pressure(atmos_pressure)
  • temp_air_bottom
  • surface_soil_heat_flux_4
  • soil_temp_1
  • soil_temp_4
  • surface_soil_heat_flux_3
  • soil_heat_flow_3
  • soil_temp_2
  • soil_heat_flow_2
  • wdir_vec_mean
  • soil_heat_capacity_2
  • soil_heat_flow_4
  • soil_heat_capacity_3
  • rh_bottom_fraction
  • soil_heat_flow_5
  • soil_temp_5
  • surface_soil_heat_flux_5
  • energy_storage_change_2
  • wspd_vec_mean
  • latent_heat_flux
  • energy_storage_change_3
  • energy_storage_change_1
  • corr_soil_heat_flow_1
  • wdir_vec_std
  • temp_trh_bottom
  • soil_temp_3
  • corr_soil_heat_flow_2
  • rh_top_fraction
  • net_radiation
  • temp_air_top


Back To Table of Contents

DQRID : D011129.6
Start DateStart TimeEnd DateEnd Time
04/10/2001194504/10/20012031
Subject:
SGP EBBR E7 - E7 EBBR AEM Position Caused Incorrect Data
DataStreams:sgp15ebbrE7.a1, sgp15ebbrE7.b1, sgp30ebbrE7.a1, sgp30ebbrE7.b1, sgp5ebbrE7.a1
Description:
The AEM stuck in one position, causing the indicated measurements and calculated
quantities to be incorrect.
Measurements:sgp5ebbrE7.a1:
  • top air temperature(tair_top)
  • bottom vapor pressure(vp_bot)
  • Temperature of bottom humidity sensor chamber(thum_bot)
  • Temperature of the top humidity chamber(thum_top)
  • top vapor pressure(vp_top)
  • Top humidity(hum_top)
  • bottom air temperature(tair_bot)
  • Bottom humidity(hum_bot)

sgp15ebbrE7.a1:
  • Temperature of left humidity sensor chamber(rr_thum_l)
  • Temperature of right humidity sensor chamber(rr_thum_r)
  • Left relative humidity(mv_hum_l)
  • Left air temperature(tair_l)
  • Right air temperature(tair_r)
  • Right relative humidity(mv_hum_r)

sgp30ebbrE7.a1:
  • ratio of sensible/latent heat fluxes (Bowen ratio)(bowen)
  • top air temperature(tair_top)
  • Top humidity(hum_top)
  • top vapor pressure(vp_top)
  • bottom air temperature(tair_bot)
  • bottom vapor pressure(vp_bot)
  • Temperature of bottom humidity sensor chamber(thum_bot)
  • latent heat flux(e)
  • h(h)
  • Bottom humidity(hum_bot)
  • Temperature of the top humidity chamber(thum_top)

sgp15ebbrE7.b1:
  • rh_right_mv
  • temp_air_right
  • temp_trh_left_rr
  • temp_trh_right_rr
  • temp_air_left
  • rh_left_mv

sgp30ebbrE7.b1:
  • temp_air_bottom
  • rh_bottom_fraction
  • latent_heat_flux
  • temp_trh_bottom
  • vapor_pressure_bottom
  • temp_trh_top
  • sensible_heat_flux
  • vapor_pressure_top
  • bowen_ratio
  • rh_top_fraction
  • temp_air_top


Back To Table of Contents

DQRID : D011129.7
Start DateStart TimeEnd DateEnd Time
05/07/2001190005/07/20011901
Subject:
SGP EBBR E7 - E7 EBBR All Data Incorrect
DataStreams:sgp15ebbrE7.a1, sgp15ebbrE7.b1, sgp30ebbrE7.a1, sgp30ebbrE7.b1, sgp5ebbrE7.a1
Description:
The data was incorrect immediately after the re-calibrated system was 
installed and put into service.
Measurements:sgp5ebbrE7.a1:
  • Temperature of the top humidity chamber(thum_top)
  • Reference Thermistor Temperature(tref)
  • Top humidity(hum_top)
  • Retrieved pressure profile(pres)
  • vector wind speed(res_ws)
  • standard deviation of wind direction (sigma theta)(sigma_wd)
  • net radiation(q)
  • Bottom humidity(hum_bot)
  • bottom vapor pressure(vp_bot)
  • Temperature of bottom humidity sensor chamber(thum_bot)
  • top vapor pressure(vp_top)
  • wind direction (relative to true north)(wind_d)
  • Home signal(home)
  • top air temperature(tair_top)
  • scalar wind speed(wind_s)
  • bottom air temperature(tair_bot)

sgp30ebbrE7.a1:
  • 0-5 cm change in soil heat storage with time, site 3(ces3)
  • wind direction (relative to true north)(wind_d)
  • soil heat flow, site 2(g2)
  • top air temperature(tair_top)
  • average surface soil heat flow(ave_shf)
  • vector wind speed(res_ws)
  • Exchange mechanism position indicator (0 to 15 min)(home_15)
  • volumetric soil moisture, site 5(sm5)
  • 0-5 cm change in soil heat storage with time, site 2(ces2)
  • 0-5 cm integrated soil temperature, site 2(ts2)
  • bottom air temperature(tair_bot)
  • volumetric soil moisture, site 4(sm4)
  • 0-5 cm integrated soil temperature, site 5(ts5)
  • standard deviation of wind direction (sigma theta)(sigma_wd)
  • Temperature of bottom humidity sensor chamber(thum_bot)
  • 0-5 cm integrated soil temperature, site 4(ts4)
  • volumetric soil moisture, site 2(sm2)
  • Soil heat capacity 2(cs2)
  • 5 cm soil heat flow corrected for soil moisture content, site 1(c_shf1)
  • volumetric soil moisture, site 1(sm1)
  • latent heat flux(e)
  • 0-5 cm change in soil heat storage with time, site 4(ces4)
  • soil heat flow, site 4(g4)
  • soil heat flow, site 3(g3)
  • Temperature of the top humidity chamber(thum_top)
  • 5 cm soil heat flow corrected for soil moisture content, site 2(c_shf2)
  • Soil heat capacity 5(cs5)
  • 5 cm soil heat flow corrected for soil moisture content, site 5(c_shf5)
  • 0-5 cm change in soil heat storage with time, site 5(ces5)
  • Soil heat capacity 3(cs3)
  • Retrieved pressure profile(pres)
  • Reference Thermistor Temperature(tref)
  • Soil heat capacity 1(cs1)
  • 5 cm soil heat flow, site 5(shf5)
  • 5 cm soil heat flow corrected for soil moisture content, site 4(c_shf4)
  • net radiation(q)
  • Exchange mechanism position indicator (15 to 30 min)(home_30)
  • Soil heat capacity 4(cs4)
  • 5 cm soil heat flow, site 1(shf1)
  • ratio of sensible/latent heat fluxes (Bowen ratio)(bowen)
  • bottom vapor pressure(vp_bot)
  • 5 cm soil heat flow, site 4(shf4)
  • h(h)
  • 5 cm soil heat flow corrected for soil moisture content, site 3(c_shf3)
  • soil heat flow, site 1(g1)
  • Top humidity(hum_top)
  • soil heat flow, site 5(g5)
  • top vapor pressure(vp_top)
  • scalar wind speed(wind_s)
  • 5 cm soil heat flow, site 2(shf2)
  • 0-5 cm integrated soil temperature, site 3(ts3)
  • 5 cm soil heat flow, site 3(shf3)
  • 0-5 cm change in soil heat storage with time, site 2(ces1)
  • Bottom humidity(hum_bot)
  • volumetric soil moisture, site 3(sm3)
  • 0-5 cm integrated soil temperature, site 2(ts1)

sgp15ebbrE7.a1:
  • Soil moisture 5(r_sm5)
  • Atmospheric pressure(mv_pres)
  • Soil temperature 5(rr_ts5)
  • Left relative humidity(mv_hum_l)
  • Soil heat flow 5(mv_hft5)
  • Soil moisture 2(r_sm2)
  • Soil temperature 4(rr_ts4)
  • Soil heat flow 4(mv_hft4)
  • Soil moisture 3(r_sm3)
  • Wind direction (relative to true north)(mv_wind_d)
  • Left air temperature(tair_l)
  • Soil moisture 2(rr_sm2)
  • Right air temperature(tair_r)
  • Soil moisture 5(rr_sm5)
  • Soil moisture 1(r_sm1)
  • Soil moisture 3(rr_sm3)
  • Soil heat flow 1(mv_hft1)
  • Soil moisture 4(r_sm4)
  • Temperature of left humidity sensor chamber(rr_thum_l)
  • Temperature of right humidity sensor chamber(rr_thum_r)
  • Soil moisture 4(rr_sm4)
  • Right relative humidity(mv_hum_r)
  • Soil moisture 1(rr_sm1)
  • Soil temperature 2(rr_ts2)
  • Soil temperature 3(rr_ts3)
  • Soil heat flow 2(mv_hft2)
  • Soil heat flow 3(mv_hft3)
  • Net radiation(mv_q)
  • Home signal(mv_home)
  • Soil temperature 1(rr_ts1)
  • Reference temperature(rr_tref)
  • scalar wind speed(wind_s)

sgp15ebbrE7.b1:
  • soil_moisture_1_rr
  • soil_heat_flow_1_mv
  • soil_temp_4_rr
  • soil_heat_flow_4_mv
  • soil_moisture_3_rr
  • soil_temp_5_rr
  • atmos_pressure_mv
  • rh_right_mv
  • soil_temp_1_rr
  • net_radiation_mv
  • soil_heat_flow_3_mv
  • soil_heat_flow_2_mv
  • soil_moisture_4_rr
  • temp_reference_rr
  • soil_moisture_5_rr
  • temp_air_right
  • temp_trh_right_rr
  • wdir_vec_mean_mv
  • temp_air_left
  • soil_temp_3_rr
  • wspd_arith_mean
  • temp_trh_left_rr
  • home_signal
  • soil_heat_flow_5_mv
  • soil_temp_2_rr
  • rh_left_mv
  • soil_moisture_2_rr

sgp30ebbrE7.b1:
  • corr_soil_heat_flow_5
  • soil_heat_capacity_5
  • soil_moisture_2
  • soil_heat_capacity_4
  • wspd_arith_mean
  • surface_soil_heat_flux_1
  • home_signal_15
  • energy_storage_change_4
  • vapor_pressure_top
  • surface_soil_heat_flux_2
  • soil_moisture_1
  • soil_moisture_3
  • corr_soil_heat_flow_4
  • surface_soil_heat_flux_avg
  • corr_soil_heat_flow_3
  • soil_moisture_5
  • energy_storage_change_5
  • soil_heat_capacity_1
  • vapor_pressure_bottom
  • temp_trh_top
  • sensible_heat_flux
  • soil_moisture_4
  • temp_reference
  • bowen_ratio
  • soil_heat_flow_1
  • Barometric Pressure(atmos_pressure)
  • temp_air_bottom
  • surface_soil_heat_flux_4
  • soil_temp_1
  • home_signal_30
  • soil_temp_4
  • surface_soil_heat_flux_3
  • soil_heat_flow_3
  • soil_temp_2
  • soil_heat_flow_2
  • wdir_vec_mean
  • soil_heat_capacity_2
  • soil_heat_flow_4
  • soil_heat_capacity_3
  • rh_bottom_fraction
  • soil_heat_flow_5
  • soil_temp_5
  • surface_soil_heat_flux_5
  • energy_storage_change_2
  • wspd_vec_mean
  • latent_heat_flux
  • energy_storage_change_3
  • energy_storage_change_1
  • corr_soil_heat_flow_1
  • wdir_vec_std
  • temp_trh_bottom
  • soil_temp_3
  • corr_soil_heat_flow_2
  • rh_top_fraction
  • net_radiation
  • temp_air_top


Back To Table of Contents

DQRID : D011129.8
Start DateStart TimeEnd DateEnd Time
05/07/2001193005/07/20011931
Subject:
SGP EBBR E7 - E7 EBBR Data Incorrect After Recalibration
DataStreams:sgp15ebbrE7.a1, sgp15ebbrE7.b1, sgp30ebbrE7.a1, sgp30ebbrE7.b1
Description:
Soil temperature measurements and the half hour average were incorrect the half hour after 
starting the recalibrated system, causing other measurements and calculated quantities 
to be incorrect.
Measurements:sgp15ebbrE7.a1:
  • Soil temperature 5(rr_ts5)
  • Soil temperature 4(rr_ts4)
  • Soil temperature 2(rr_ts2)
  • Soil temperature 3(rr_ts3)
  • Soil temperature 1(rr_ts1)

sgp30ebbrE7.a1:
  • 0-5 cm change in soil heat storage with time, site 3(ces3)
  • soil heat flow, site 2(g2)
  • 0-5 cm change in soil heat storage with time, site 2(ces2)
  • 0-5 cm integrated soil temperature, site 2(ts2)
  • 0-5 cm integrated soil temperature, site 5(ts5)
  • 0-5 cm integrated soil temperature, site 4(ts4)
  • latent heat flux(e)
  • 0-5 cm change in soil heat storage with time, site 4(ces4)
  • soil heat flow, site 4(g4)
  • h(h)
  • soil heat flow, site 3(g3)
  • soil heat flow, site 1(g1)
  • soil heat flow, site 5(g5)
  • 0-5 cm change in soil heat storage with time, site 5(ces5)
  • 0-5 cm integrated soil temperature, site 3(ts3)
  • 0-5 cm change in soil heat storage with time, site 2(ces1)
  • 0-5 cm integrated soil temperature, site 2(ts1)

sgp15ebbrE7.b1:
  • soil_temp_4_rr
  • soil_temp_3_rr
  • soil_temp_5_rr
  • soil_temp_1_rr
  • soil_temp_2_rr

sgp30ebbrE7.b1:
  • soil_moisture_2
  • soil_temp_1
  • surface_soil_heat_flux_4
  • soil_temp_4
  • surface_soil_heat_flux_3
  • soil_temp_2
  • surface_soil_heat_flux_1
  • energy_storage_change_4
  • surface_soil_heat_flux_2
  • soil_moisture_1
  • soil_moisture_3
  • soil_temp_5
  • soil_moisture_5
  • energy_storage_change_2
  • surface_soil_heat_flux_5
  • energy_storage_change_5
  • latent_heat_flux
  • energy_storage_change_1
  • energy_storage_change_3
  • soil_temp_3
  • sensible_heat_flux
  • soil_moisture_4


Back To Table of Contents

DQRID : D011129.9
Start DateStart TimeEnd DateEnd Time
08/28/2001190008/28/20011901
Subject:
SGP EBBR E7 - E7 EBBR Data Incorrect After Missing Data Period
DataStreams:sgp15ebbrE7.a1, sgp15ebbrE7.b1, sgp30ebbrE7.a1, sgp30ebbrE7.b1
Description:
Soil temperature measurements and the half hour average were incorrect the half hour after 
a missing data period, causing other measurements and calculated quantities to be 
incorrect.
Measurements:sgp15ebbrE7.a1:
  • Soil temperature 5(rr_ts5)
  • Soil temperature 4(rr_ts4)
  • Soil temperature 2(rr_ts2)
  • Soil temperature 3(rr_ts3)
  • Soil temperature 1(rr_ts1)

sgp30ebbrE7.a1:
  • 0-5 cm change in soil heat storage with time, site 3(ces3)
  • soil heat flow, site 2(g2)
  • 0-5 cm change in soil heat storage with time, site 2(ces2)
  • 0-5 cm integrated soil temperature, site 2(ts2)
  • 0-5 cm integrated soil temperature, site 5(ts5)
  • 0-5 cm integrated soil temperature, site 4(ts4)
  • latent heat flux(e)
  • 0-5 cm change in soil heat storage with time, site 4(ces4)
  • soil heat flow, site 4(g4)
  • h(h)
  • soil heat flow, site 3(g3)
  • soil heat flow, site 1(g1)
  • soil heat flow, site 5(g5)
  • 0-5 cm change in soil heat storage with time, site 5(ces5)
  • 0-5 cm integrated soil temperature, site 3(ts3)
  • 0-5 cm change in soil heat storage with time, site 2(ces1)
  • 0-5 cm integrated soil temperature, site 2(ts1)

sgp15ebbrE7.b1:
  • soil_temp_4_rr
  • soil_temp_3_rr
  • soil_temp_5_rr
  • soil_temp_1_rr
  • soil_temp_2_rr

sgp30ebbrE7.b1:
  • soil_moisture_2
  • soil_temp_1
  • surface_soil_heat_flux_4
  • soil_temp_4
  • surface_soil_heat_flux_3
  • soil_temp_2
  • surface_soil_heat_flux_1
  • energy_storage_change_4
  • surface_soil_heat_flux_2
  • soil_moisture_1
  • soil_moisture_3
  • soil_temp_5
  • soil_moisture_5
  • energy_storage_change_2
  • surface_soil_heat_flux_5
  • energy_storage_change_5
  • latent_heat_flux
  • energy_storage_change_1
  • energy_storage_change_3
  • soil_temp_3
  • sensible_heat_flux
  • soil_moisture_4


Back To Table of Contents

DQRID : D020716.26
Start DateStart TimeEnd DateEnd Time
03/12/2002210003/12/20022101
Subject:
SGP/EBBR/E7 - Measurements Zero
DataStreams:sgp15ebbrE7.a1, sgp15ebbrE7.b1, sgp30ebbrE7.a1, sgp30ebbrE7.b1, sgp5ebbrE7.00,
sgp5ebbrE7.a1
Description:
The indicated measurements were zero after interruption of the CR10 program.
Measurements:sgp5ebbrE7.00:
  • null(Raw data stream - documentation not supported)

sgp5ebbrE7.a1:
  • Temperature of the top humidity chamber(thum_top)
  • Reference Thermistor Temperature(tref)
  • Top humidity(hum_top)
  • Retrieved pressure profile(pres)
  • vector wind speed(res_ws)
  • standard deviation of wind direction (sigma theta)(sigma_wd)
  • net radiation(q)
  • Bottom humidity(hum_bot)
  • bottom vapor pressure(vp_bot)
  • Temperature of bottom humidity sensor chamber(thum_bot)
  • top vapor pressure(vp_top)
  • wind direction (relative to true north)(wind_d)
  • Home signal(home)
  • top air temperature(tair_top)
  • scalar wind speed(wind_s)
  • bottom air temperature(tair_bot)

sgp30ebbrE7.a1:
  • 0-5 cm change in soil heat storage with time, site 3(ces3)
  • wind direction (relative to true north)(wind_d)
  • soil heat flow, site 2(g2)
  • top air temperature(tair_top)
  • average surface soil heat flow(ave_shf)
  • vector wind speed(res_ws)
  • Exchange mechanism position indicator (0 to 15 min)(home_15)
  • volumetric soil moisture, site 5(sm5)
  • 0-5 cm change in soil heat storage with time, site 2(ces2)
  • 0-5 cm integrated soil temperature, site 2(ts2)
  • bottom air temperature(tair_bot)
  • volumetric soil moisture, site 4(sm4)
  • standard deviation of wind direction (sigma theta)(sigma_wd)
  • 0-5 cm integrated soil temperature, site 5(ts5)
  • Temperature of bottom humidity sensor chamber(thum_bot)
  • 0-5 cm integrated soil temperature, site 4(ts4)
  • volumetric soil moisture, site 2(sm2)
  • Soil heat capacity 2(cs2)
  • 5 cm soil heat flow corrected for soil moisture content, site 1(c_shf1)
  • volumetric soil moisture, site 1(sm1)
  • latent heat flux(e)
  • 0-5 cm change in soil heat storage with time, site 4(ces4)
  • soil heat flow, site 4(g4)
  • soil heat flow, site 3(g3)
  • Temperature of the top humidity chamber(thum_top)
  • 5 cm soil heat flow corrected for soil moisture content, site 2(c_shf2)
  • Soil heat capacity 5(cs5)
  • 5 cm soil heat flow corrected for soil moisture content, site 5(c_shf5)
  • 0-5 cm change in soil heat storage with time, site 5(ces5)
  • Soil heat capacity 3(cs3)
  • Retrieved pressure profile(pres)
  • Reference Thermistor Temperature(tref)
  • Soil heat capacity 1(cs1)
  • 5 cm soil heat flow, site 5(shf5)
  • 5 cm soil heat flow corrected for soil moisture content, site 4(c_shf4)
  • net radiation(q)
  • Exchange mechanism position indicator (15 to 30 min)(home_30)
  • Soil heat capacity 4(cs4)
  • 5 cm soil heat flow, site 1(shf1)
  • ratio of sensible/latent heat fluxes (Bowen ratio)(bowen)
  • bottom vapor pressure(vp_bot)
  • 5 cm soil heat flow, site 4(shf4)
  • h(h)
  • 5 cm soil heat flow corrected for soil moisture content, site 3(c_shf3)
  • soil heat flow, site 1(g1)
  • Top humidity(hum_top)
  • soil heat flow, site 5(g5)
  • top vapor pressure(vp_top)
  • scalar wind speed(wind_s)
  • 5 cm soil heat flow, site 2(shf2)
  • 0-5 cm integrated soil temperature, site 3(ts3)
  • 5 cm soil heat flow, site 3(shf3)
  • 0-5 cm change in soil heat storage with time, site 2(ces1)
  • Bottom humidity(hum_bot)
  • volumetric soil moisture, site 3(sm3)
  • 0-5 cm integrated soil temperature, site 2(ts1)

sgp15ebbrE7.a1:
  • Soil moisture 5(r_sm5)
  • Atmospheric pressure(mv_pres)
  • Soil temperature 5(rr_ts5)
  • Left relative humidity(mv_hum_l)
  • Soil heat flow 5(mv_hft5)
  • Soil moisture 2(r_sm2)
  • Soil temperature 4(rr_ts4)
  • Soil heat flow 4(mv_hft4)
  • Soil moisture 3(r_sm3)
  • Battery(bat)
  • Wind direction (relative to true north)(mv_wind_d)
  • Left air temperature(tair_l)
  • Soil moisture 2(rr_sm2)
  • Right air temperature(tair_r)
  • Soil moisture 5(rr_sm5)
  • Soil moisture 1(r_sm1)
  • Soil moisture 3(rr_sm3)
  • Soil heat flow 1(mv_hft1)
  • Soil moisture 4(r_sm4)
  • Temperature of left humidity sensor chamber(rr_thum_l)
  • Temperature of right humidity sensor chamber(rr_thum_r)
  • Soil moisture 4(rr_sm4)
  • Right relative humidity(mv_hum_r)
  • Soil moisture 1(rr_sm1)
  • Soil temperature 2(rr_ts2)
  • Soil temperature 3(rr_ts3)
  • Soil heat flow 2(mv_hft2)
  • Soil heat flow 3(mv_hft3)
  • Net radiation(mv_q)
  • Home signal(mv_home)
  • Soil temperature 1(rr_ts1)
  • Reference temperature(rr_tref)
  • scalar wind speed(wind_s)

sgp15ebbrE7.b1:
  • soil_moisture_1_rr
  • soil_heat_flow_1_mv
  • soil_temp_4_rr
  • soil_heat_flow_4_mv
  • soil_moisture_3_rr
  • soil_temp_5_rr
  • atmos_pressure_mv
  • rh_right_mv
  • soil_temp_1_rr
  • net_radiation_mv
  • battery_voltage
  • soil_heat_flow_3_mv
  • soil_heat_flow_2_mv
  • soil_moisture_4_rr
  • temp_reference_rr
  • soil_moisture_5_rr
  • temp_air_right
  • temp_trh_right_rr
  • wdir_vec_mean_mv
  • temp_air_left
  • soil_temp_3_rr
  • wspd_arith_mean
  • temp_trh_left_rr
  • home_signal
  • soil_heat_flow_5_mv
  • soil_temp_2_rr
  • rh_left_mv
  • soil_moisture_2_rr

sgp30ebbrE7.b1:
  • corr_soil_heat_flow_5
  • soil_heat_capacity_5
  • soil_moisture_2
  • soil_heat_capacity_4
  • wspd_arith_mean
  • surface_soil_heat_flux_1
  • home_signal_15
  • energy_storage_change_4
  • vapor_pressure_top
  • surface_soil_heat_flux_2
  • soil_moisture_1
  • soil_moisture_3
  • corr_soil_heat_flow_4
  • surface_soil_heat_flux_avg
  • corr_soil_heat_flow_3
  • soil_moisture_5
  • energy_storage_change_5
  • soil_heat_capacity_1
  • vapor_pressure_bottom
  • temp_trh_top
  • sensible_heat_flux
  • soil_moisture_4
  • temp_reference
  • bowen_ratio
  • soil_heat_flow_1
  • Barometric Pressure(atmos_pressure)
  • temp_air_bottom
  • surface_soil_heat_flux_4
  • soil_temp_1
  • home_signal_30
  • soil_temp_4
  • surface_soil_heat_flux_3
  • soil_heat_flow_3
  • soil_temp_2
  • soil_heat_flow_2
  • wdir_vec_mean
  • soil_heat_capacity_2
  • soil_heat_flow_4
  • soil_heat_capacity_3
  • rh_bottom_fraction
  • soil_heat_flow_5
  • soil_temp_5
  • surface_soil_heat_flux_5
  • energy_storage_change_2
  • wspd_vec_mean
  • latent_heat_flux
  • energy_storage_change_3
  • energy_storage_change_1
  • corr_soil_heat_flow_1
  • wdir_vec_std
  • temp_trh_bottom
  • soil_temp_3
  • corr_soil_heat_flow_2
  • rh_top_fraction
  • net_radiation
  • temp_air_top


Back To Table of Contents

DQRID : D020716.27
Start DateStart TimeEnd DateEnd Time
04/14/2002220004/23/20021531
05/20/2002120006/06/20021501
Subject:
SGP/EBBR/E7 - AEM Hung
DataStreams:sgp15ebbrE7.a1, sgp15ebbrE7.b1, sgp30ebbrE7.a1, sgp30ebbrE7.b1, sgp5ebbrE7.a1
Description:
The indicated measurements were incorrect because the automatic exchange mechanism hung in 
one position.
Measurements:sgp5ebbrE7.a1:
  • top air temperature(tair_top)
  • bottom vapor pressure(vp_bot)
  • Temperature of bottom humidity sensor chamber(thum_bot)
  • Temperature of the top humidity chamber(thum_top)
  • top vapor pressure(vp_top)
  • Top humidity(hum_top)
  • bottom air temperature(tair_bot)
  • Bottom humidity(hum_bot)

sgp15ebbrE7.a1:
  • Left air temperature(tair_l)
  • Right air temperature(tair_r)

sgp30ebbrE7.a1:
  • ratio of sensible/latent heat fluxes (Bowen ratio)(bowen)
  • top air temperature(tair_top)
  • Top humidity(hum_top)
  • top vapor pressure(vp_top)
  • bottom air temperature(tair_bot)
  • bottom vapor pressure(vp_bot)
  • Temperature of bottom humidity sensor chamber(thum_bot)
  • latent heat flux(e)
  • h(h)
  • Bottom humidity(hum_bot)
  • Temperature of the top humidity chamber(thum_top)

sgp15ebbrE7.b1:
  • temp_air_right
  • temp_air_left

sgp30ebbrE7.b1:
  • temp_air_bottom
  • rh_bottom_fraction
  • latent_heat_flux
  • temp_trh_bottom
  • vapor_pressure_bottom
  • temp_trh_top
  • sensible_heat_flux
  • vapor_pressure_top
  • bowen_ratio
  • rh_top_fraction
  • temp_air_top


Back To Table of Contents

DQRID : D020716.28
Start DateStart TimeEnd DateEnd Time
05/20/2002120005/21/20021601
Subject:
SGP/EBBR/E7 - Wind Speed Incorrect
DataStreams:sgp15ebbrE7.a1, sgp15ebbrE7.b1, sgp30ebbrE7.a1, sgp30ebbrE7.b1, sgp5ebbrE7.a1
Description:
The wind speed and resultant wind speed are incorrect for the indicated times because a 
cup had broken off of the cup anemometer.
Measurements:sgp5ebbrE7.a1:
  • vector wind speed(res_ws)
  • scalar wind speed(wind_s)

sgp15ebbrE7.a1:
  • scalar wind speed(wind_s)

sgp30ebbrE7.a1:
  • scalar wind speed(wind_s)
  • vector wind speed(res_ws)

sgp30ebbrE7.b1:
  • wspd_arith_mean
  • wspd_vec_mean

sgp15ebbrE7.b1:
  • wspd_arith_mean


Back To Table of Contents

DQRID : D020716.8
Start DateStart TimeEnd DateEnd Time
05/07/2002164505/07/20021716
Subject:
SGP/EBBR/E7 - 6 Month Checks
DataStreams:sgp15ebbrE7.a1, sgp15ebbrE7.b1, sgp30ebbrE7.a1, sgp30ebbrE7.b1, sgp5ebbrE7.a1
Description:
The indicated measurements were incorrect during the 6 month checks.
Measurements:sgp5ebbrE7.a1:
  • top air temperature(tair_top)
  • bottom vapor pressure(vp_bot)
  • Temperature of bottom humidity sensor chamber(thum_bot)
  • Temperature of the top humidity chamber(thum_top)
  • top vapor pressure(vp_top)
  • Top humidity(hum_top)
  • bottom air temperature(tair_bot)
  • Bottom humidity(hum_bot)

sgp15ebbrE7.a1:
  • Left air temperature(tair_l)
  • Right air temperature(tair_r)

sgp30ebbrE7.a1:
  • ratio of sensible/latent heat fluxes (Bowen ratio)(bowen)
  • top air temperature(tair_top)
  • Top humidity(hum_top)
  • top vapor pressure(vp_top)
  • bottom air temperature(tair_bot)
  • bottom vapor pressure(vp_bot)
  • Temperature of bottom humidity sensor chamber(thum_bot)
  • latent heat flux(e)
  • h(h)
  • Bottom humidity(hum_bot)
  • Temperature of the top humidity chamber(thum_top)

sgp15ebbrE7.b1:
  • temp_air_right
  • temp_air_left

sgp30ebbrE7.b1:
  • temp_air_bottom
  • rh_bottom_fraction
  • latent_heat_flux
  • temp_trh_bottom
  • vapor_pressure_bottom
  • temp_trh_top
  • sensible_heat_flux
  • vapor_pressure_top
  • bowen_ratio
  • rh_top_fraction
  • temp_air_top


Back To Table of Contents

DQRID : D021113.1
Start DateStart TimeEnd DateEnd Time
04/01/2001000006/18/20032359
Subject:
SGP/EBBR - Incorrect Units for Soil Heat Capacity (cs1, cs2, cs3, cs4, cs5) in 30EBBR 
Header
DataStreams:sgp30ebbrE12.b1, sgp30ebbrE13.b1, sgp30ebbrE15.b1, sgp30ebbrE18.b1, sgp30ebbrE19.b1,
sgp30ebbrE2.b1, sgp30ebbrE20.b1, sgp30ebbrE22.b1, sgp30ebbrE26.b1, sgp30ebbrE4.b1,
sgp30ebbrE7.b1, sgp30ebbrE8.b1, sgp30ebbrE9.b1
Description:
The units for Soil Heat Capacity (cs1, cs2, cs3, cs4, cs5) in the 
EBBR 30 minute netcdf header have been incorrect from the beginning 
of processing the data into netcdf files.  The correct units are 
MJ/m^3/C.

This does not affect the data quality.
Measurements:sgp30ebbrE8.b1:
  • soil_heat_capacity_2
  • soil_heat_capacity_1
  • soil_heat_capacity_3
  • soil_heat_capacity_5
  • soil_heat_capacity_4

sgp30ebbrE4.b1:
  • soil_heat_capacity_4
  • soil_heat_capacity_2
  • soil_heat_capacity_3
  • soil_heat_capacity_5
  • soil_heat_capacity_1

sgp30ebbrE9.b1:
  • soil_heat_capacity_3
  • soil_heat_capacity_5
  • soil_heat_capacity_1
  • soil_heat_capacity_4
  • soil_heat_capacity_2

sgp30ebbrE18.b1:
  • soil_heat_capacity_1
  • soil_heat_capacity_2
  • soil_heat_capacity_3
  • soil_heat_capacity_4
  • soil_heat_capacity_5

sgp30ebbrE26.b1:
  • soil_heat_capacity_3
  • soil_heat_capacity_4
  • soil_heat_capacity_5
  • soil_heat_capacity_2
  • soil_heat_capacity_1

sgp30ebbrE13.b1:
  • soil_heat_capacity_3
  • soil_heat_capacity_5
  • soil_heat_capacity_4
  • soil_heat_capacity_2
  • soil_heat_capacity_1

sgp30ebbrE7.b1:
  • soil_heat_capacity_5
  • soil_heat_capacity_4
  • soil_heat_capacity_2
  • soil_heat_capacity_3
  • soil_heat_capacity_1

sgp30ebbrE12.b1:
  • soil_heat_capacity_2
  • soil_heat_capacity_4
  • soil_heat_capacity_3
  • soil_heat_capacity_1
  • soil_heat_capacity_5

sgp30ebbrE19.b1:
  • soil_heat_capacity_4
  • soil_heat_capacity_5
  • soil_heat_capacity_3
  • soil_heat_capacity_1
  • soil_heat_capacity_2

sgp30ebbrE20.b1:
  • soil_heat_capacity_2
  • soil_heat_capacity_1
  • soil_heat_capacity_5
  • soil_heat_capacity_3
  • soil_heat_capacity_4

sgp30ebbrE22.b1:
  • soil_heat_capacity_3
  • soil_heat_capacity_5
  • soil_heat_capacity_2
  • soil_heat_capacity_4
  • soil_heat_capacity_1

sgp30ebbrE2.b1:
  • soil_heat_capacity_5
  • soil_heat_capacity_4
  • soil_heat_capacity_1
  • soil_heat_capacity_3
  • soil_heat_capacity_2

sgp30ebbrE15.b1:
  • soil_heat_capacity_5
  • soil_heat_capacity_1
  • soil_heat_capacity_3
  • soil_heat_capacity_2
  • soil_heat_capacity_4


Back To Table of Contents

DQRID : D030110.30
Start DateStart TimeEnd DateEnd Time
11/19/2002200011/19/20022030
Subject:
SGP/EBBR/E7 - Data Incorrect during 6 month checks
DataStreams:sgp15ebbrE7.a1, sgp15ebbrE7.b1, sgp30ebbrE7.a1, sgp30ebbrE7.b1, sgp5ebbrE7.a1
Description:
Some of the measurements are incorrect during the 6 month checks.
Measurements:sgp5ebbrE7.a1:
  • top air temperature(tair_top)
  • bottom vapor pressure(vp_bot)
  • Temperature of bottom humidity sensor chamber(thum_bot)
  • Temperature of the top humidity chamber(thum_top)
  • top vapor pressure(vp_top)
  • Top humidity(hum_top)
  • bottom air temperature(tair_bot)
  • Bottom humidity(hum_bot)

sgp15ebbrE7.a1:
  • Left air temperature(tair_l)
  • Right air temperature(tair_r)

sgp30ebbrE7.a1:
  • ratio of sensible/latent heat fluxes (Bowen ratio)(bowen)
  • top air temperature(tair_top)
  • Top humidity(hum_top)
  • top vapor pressure(vp_top)
  • bottom air temperature(tair_bot)
  • bottom vapor pressure(vp_bot)
  • Temperature of bottom humidity sensor chamber(thum_bot)
  • latent heat flux(e)
  • h(h)
  • Bottom humidity(hum_bot)
  • Temperature of the top humidity chamber(thum_top)

sgp15ebbrE7.b1:
  • temp_air_right
  • temp_air_left

sgp30ebbrE7.b1:
  • temp_air_bottom
  • rh_bottom_fraction
  • latent_heat_flux
  • temp_trh_bottom
  • vapor_pressure_bottom
  • temp_trh_top
  • sensible_heat_flux
  • vapor_pressure_top
  • bowen_ratio
  • rh_top_fraction
  • temp_air_top


Back To Table of Contents

DQRID : D030113.1
Start DateStart TimeEnd DateEnd Time
07/11/2002210007/18/20021700
Subject:
SGP/EBBR/E7 - Wind speed incorrect
DataStreams:sgp15ebbrE7.a1, sgp15ebbrE7.b1, sgp30ebbrE7.a1, sgp30ebbrE7.b1, sgp5ebbrE7.a1
Description:
A wind speed sensor electronics problem limited the
measurement to the sensor offset.  This data was incorrect.
Measurements:sgp5ebbrE7.a1:
  • vector wind speed(res_ws)
  • scalar wind speed(wind_s)

sgp15ebbrE7.a1:
  • scalar wind speed(wind_s)

sgp30ebbrE7.a1:
  • scalar wind speed(wind_s)
  • vector wind speed(res_ws)

sgp30ebbrE7.b1:
  • wspd_arith_mean
  • wspd_vec_mean

sgp15ebbrE7.b1:
  • wspd_arith_mean


Back To Table of Contents

DQRID : D030113.3
Start DateStart TimeEnd DateEnd Time
07/30/2002190007/30/20021901
Subject:
SGP/EBBR/E7 - CES data incorrect
DataStreams:sgp30ebbrE7.a1, sgp30ebbrE7.b1
Description:
After a missing half hour, the soil temperature at the beginning of the half hour cannot 
be used to determine the soil energy storage term.  Therefore the
change of energy calculation blows up.  The indicated measurements are therefore 
incorrect.
Measurements:sgp30ebbrE7.a1:
  • 0-5 cm change in soil heat storage with time, site 3(ces3)
  • soil heat flow, site 2(g2)
  • average surface soil heat flow(ave_shf)
  • soil heat flow, site 1(g1)
  • 0-5 cm change in soil heat storage with time, site 2(ces2)
  • soil heat flow, site 5(g5)
  • 0-5 cm change in soil heat storage with time, site 5(ces5)
  • latent heat flux(e)
  • 0-5 cm change in soil heat storage with time, site 4(ces4)
  • soil heat flow, site 4(g4)
  • 0-5 cm change in soil heat storage with time, site 2(ces1)
  • h(h)
  • soil heat flow, site 3(g3)

sgp30ebbrE7.b1:
  • surface_soil_heat_flux_4
  • surface_soil_heat_flux_avg
  • surface_soil_heat_flux_3
  • energy_storage_change_2
  • surface_soil_heat_flux_5
  • energy_storage_change_5
  • latent_heat_flux
  • energy_storage_change_1
  • energy_storage_change_3
  • surface_soil_heat_flux_1
  • energy_storage_change_4
  • sensible_heat_flux
  • surface_soil_heat_flux_2


Back To Table of Contents

DQRID : D030113.4
Start DateStart TimeEnd DateEnd Time
11/05/2002210011/05/20022129
Subject:
SGP/EBBR/E7 - REPROCESS: Soil Heat Flow #2 Incorrect
DataStreams:sgp30ebbrE7.a1, sgp30ebbrE7.b1
Description:
Soil Heat Flow #2 measurements were incorrect while it was being replaced.
Measurements:sgp30ebbrE7.a1:
  • latent heat flux(e)
  • 5 cm soil heat flow corrected for soil moisture content, site 2(c_shf2)
  • soil heat flow, site 2(g2)
  • average surface soil heat flow(ave_shf)
  • h(h)
  • 5 cm soil heat flow, site 2(shf2)

sgp30ebbrE7.b1:
  • surface_soil_heat_flux_avg
  • latent_heat_flux
  • sensible_heat_flux
  • soil_heat_flow_2
  • surface_soil_heat_flux_2
  • corr_soil_heat_flow_2


Back To Table of Contents

DQRID : D030113.5
Start DateStart TimeEnd DateEnd Time
11/05/2002213011/05/20022159
Subject:
SGP/EBBR/E7 - Change In Energy Storage Calculations Incorrect
DataStreams:sgp30ebbrE7.a1, sgp30ebbrE7.b1
Description:
Because soil temperature measurements were not available from the beginning of the half 
hour, the change in soil energy storage could not be calculated and thus is incorrect.
Measurements:sgp30ebbrE7.a1:
  • 0-5 cm change in soil heat storage with time, site 3(ces3)
  • soil heat flow, site 2(g2)
  • average surface soil heat flow(ave_shf)
  • soil heat flow, site 1(g1)
  • 0-5 cm change in soil heat storage with time, site 2(ces2)
  • soil heat flow, site 5(g5)
  • 0-5 cm change in soil heat storage with time, site 5(ces5)
  • latent heat flux(e)
  • 0-5 cm change in soil heat storage with time, site 4(ces4)
  • soil heat flow, site 4(g4)
  • 0-5 cm change in soil heat storage with time, site 2(ces1)
  • h(h)
  • soil heat flow, site 3(g3)

sgp30ebbrE7.b1:
  • surface_soil_heat_flux_4
  • surface_soil_heat_flux_avg
  • surface_soil_heat_flux_3
  • energy_storage_change_2
  • surface_soil_heat_flux_5
  • energy_storage_change_5
  • latent_heat_flux
  • energy_storage_change_1
  • energy_storage_change_3
  • surface_soil_heat_flux_1
  • energy_storage_change_4
  • sensible_heat_flux
  • surface_soil_heat_flux_2


Back To Table of Contents

DQRID : D030113.6
Start DateStart TimeEnd DateEnd Time
09/22/2002163012/03/20021830
Subject:
SGP/EBBR/E7 - REPROCESS: Soil Heat Flow #5 too low
DataStreams:sgp30ebbrE7.a1, sgp30ebbrE7.b1
Description:
Soil Heat Flow #5 was sometimes 2X the other soil heat flow measurements when
heat flows were negative.  This does not usually greatly affect h and e, therefore the 
data color has been set to yellow.
Measurements:sgp30ebbrE7.a1:
  • latent heat flux(e)
  • 5 cm soil heat flow, site 5(shf5)
  • average surface soil heat flow(ave_shf)
  • h(h)
  • 5 cm soil heat flow corrected for soil moisture content, site 5(c_shf5)
  • soil heat flow, site 5(g5)

sgp30ebbrE7.b1:
  • surface_soil_heat_flux_avg
  • corr_soil_heat_flow_5
  • latent_heat_flux
  • soil_heat_flow_5
  • sensible_heat_flux
  • surface_soil_heat_flux_5


Back To Table of Contents

DQRID : D030113.7
Start DateStart TimeEnd DateEnd Time
07/10/2002080007/16/20021900
07/22/2002163007/30/20021630
08/24/2002023008/27/20021800
Subject:
SGP/EBBR/E7 - AEM Problems
DataStreams:sgp15ebbrE7.a1, sgp15ebbrE7.b1, sgp30ebbrE7.a1, sgp30ebbrE7.b1, sgp5ebbrE7.a1
Description:
The AEM (Automatic Exchange Mechanism) hung in a non-home position for
a few lengthy periods, during which the indicated measurements are incorrect.
Measurements:sgp5ebbrE7.a1:
  • top air temperature(tair_top)
  • bottom vapor pressure(vp_bot)
  • Temperature of bottom humidity sensor chamber(thum_bot)
  • Temperature of the top humidity chamber(thum_top)
  • top vapor pressure(vp_top)
  • Top humidity(hum_top)
  • bottom air temperature(tair_bot)
  • Bottom humidity(hum_bot)

sgp15ebbrE7.a1:
  • Left air temperature(tair_l)
  • Right air temperature(tair_r)

sgp30ebbrE7.a1:
  • ratio of sensible/latent heat fluxes (Bowen ratio)(bowen)
  • top air temperature(tair_top)
  • Top humidity(hum_top)
  • top vapor pressure(vp_top)
  • bottom air temperature(tair_bot)
  • bottom vapor pressure(vp_bot)
  • Temperature of bottom humidity sensor chamber(thum_bot)
  • latent heat flux(e)
  • h(h)
  • Bottom humidity(hum_bot)
  • Temperature of the top humidity chamber(thum_top)

sgp15ebbrE7.b1:
  • temp_air_right
  • temp_air_left

sgp30ebbrE7.b1:
  • temp_air_bottom
  • rh_bottom_fraction
  • latent_heat_flux
  • temp_trh_bottom
  • vapor_pressure_bottom
  • temp_trh_top
  • sensible_heat_flux
  • vapor_pressure_top
  • bowen_ratio
  • rh_top_fraction
  • temp_air_top


Back To Table of Contents

DQRID : D030113.8
Start DateStart TimeEnd DateEnd Time
10/01/2002170010/08/20021645
Subject:
SGP/EBBR/E7 - T/RH Ventilator Fans Stopped
DataStreams:sgp15ebbrE7.a1, sgp15ebbrE7.b1, sgp30ebbrE7.a1, sgp30ebbrE7.b1, sgp5ebbrE7.a1
Description:
The temperature and relative humidity gradients are suspect because the 
ventilator fans were not operating during this time period. The data needs
to be carefully inspected to determine when measurements, if any, are correct.
Measurements:sgp5ebbrE7.a1:
  • top air temperature(tair_top)
  • bottom vapor pressure(vp_bot)
  • Temperature of bottom humidity sensor chamber(thum_bot)
  • Temperature of the top humidity chamber(thum_top)
  • top vapor pressure(vp_top)
  • Top humidity(hum_top)
  • bottom air temperature(tair_bot)
  • Bottom humidity(hum_bot)

sgp15ebbrE7.a1:
  • Left air temperature(tair_l)
  • Right air temperature(tair_r)

sgp30ebbrE7.a1:
  • ratio of sensible/latent heat fluxes (Bowen ratio)(bowen)
  • top air temperature(tair_top)
  • Top humidity(hum_top)
  • top vapor pressure(vp_top)
  • bottom air temperature(tair_bot)
  • bottom vapor pressure(vp_bot)
  • Temperature of bottom humidity sensor chamber(thum_bot)
  • latent heat flux(e)
  • h(h)
  • Bottom humidity(hum_bot)
  • Temperature of the top humidity chamber(thum_top)

sgp15ebbrE7.b1:
  • temp_air_right
  • temp_air_left

sgp30ebbrE7.b1:
  • temp_air_bottom
  • rh_bottom_fraction
  • latent_heat_flux
  • temp_trh_bottom
  • vapor_pressure_bottom
  • temp_trh_top
  • sensible_heat_flux
  • vapor_pressure_top
  • bowen_ratio
  • rh_top_fraction
  • temp_air_top


Back To Table of Contents

DQRID : D030114.2
Start DateStart TimeEnd DateEnd Time
07/30/2002180007/30/20021829
Subject:
SGP/EBBR/E7 - Data Reported as Zero following Logger Replacement
DataStreams:sgp15ebbrE7.a1, sgp15ebbrE7.b1, sgp30ebbrE7.a1, sgp30ebbrE7.b1, sgp5ebbrE7.a1
Description:
The data was reported as zero after a data logger replacement.
Measurements:sgp5ebbrE7.a1:
  • Temperature of the top humidity chamber(thum_top)
  • Reference Thermistor Temperature(tref)
  • Top humidity(hum_top)
  • Retrieved pressure profile(pres)
  • vector wind speed(res_ws)
  • standard deviation of wind direction (sigma theta)(sigma_wd)
  • net radiation(q)
  • Bottom humidity(hum_bot)
  • bottom vapor pressure(vp_bot)
  • Temperature of bottom humidity sensor chamber(thum_bot)
  • top vapor pressure(vp_top)
  • wind direction (relative to true north)(wind_d)
  • Home signal(home)
  • top air temperature(tair_top)
  • scalar wind speed(wind_s)
  • bottom air temperature(tair_bot)

sgp30ebbrE7.a1:
  • 0-5 cm change in soil heat storage with time, site 3(ces3)
  • wind direction (relative to true north)(wind_d)
  • soil heat flow, site 2(g2)
  • top air temperature(tair_top)
  • average surface soil heat flow(ave_shf)
  • vector wind speed(res_ws)
  • Exchange mechanism position indicator (0 to 15 min)(home_15)
  • volumetric soil moisture, site 5(sm5)
  • 0-5 cm change in soil heat storage with time, site 2(ces2)
  • 0-5 cm integrated soil temperature, site 2(ts2)
  • bottom air temperature(tair_bot)
  • volumetric soil moisture, site 4(sm4)
  • standard deviation of wind direction (sigma theta)(sigma_wd)
  • 0-5 cm integrated soil temperature, site 5(ts5)
  • Temperature of bottom humidity sensor chamber(thum_bot)
  • 0-5 cm integrated soil temperature, site 4(ts4)
  • volumetric soil moisture, site 2(sm2)
  • Soil heat capacity 2(cs2)
  • 5 cm soil heat flow corrected for soil moisture content, site 1(c_shf1)
  • volumetric soil moisture, site 1(sm1)
  • latent heat flux(e)
  • 0-5 cm change in soil heat storage with time, site 4(ces4)
  • soil heat flow, site 4(g4)
  • soil heat flow, site 3(g3)
  • Temperature of the top humidity chamber(thum_top)
  • 5 cm soil heat flow corrected for soil moisture content, site 2(c_shf2)
  • Soil heat capacity 5(cs5)
  • 5 cm soil heat flow corrected for soil moisture content, site 5(c_shf5)
  • 0-5 cm change in soil heat storage with time, site 5(ces5)
  • Soil heat capacity 3(cs3)
  • Retrieved pressure profile(pres)
  • Reference Thermistor Temperature(tref)
  • Soil heat capacity 1(cs1)
  • 5 cm soil heat flow, site 5(shf5)
  • 5 cm soil heat flow corrected for soil moisture content, site 4(c_shf4)
  • net radiation(q)
  • Exchange mechanism position indicator (15 to 30 min)(home_30)
  • Soil heat capacity 4(cs4)
  • 5 cm soil heat flow, site 1(shf1)
  • ratio of sensible/latent heat fluxes (Bowen ratio)(bowen)
  • bottom vapor pressure(vp_bot)
  • 5 cm soil heat flow, site 4(shf4)
  • h(h)
  • 5 cm soil heat flow corrected for soil moisture content, site 3(c_shf3)
  • soil heat flow, site 1(g1)
  • Top humidity(hum_top)
  • soil heat flow, site 5(g5)
  • top vapor pressure(vp_top)
  • scalar wind speed(wind_s)
  • 5 cm soil heat flow, site 2(shf2)
  • 0-5 cm integrated soil temperature, site 3(ts3)
  • 5 cm soil heat flow, site 3(shf3)
  • 0-5 cm change in soil heat storage with time, site 2(ces1)
  • Bottom humidity(hum_bot)
  • volumetric soil moisture, site 3(sm3)
  • 0-5 cm integrated soil temperature, site 2(ts1)

sgp15ebbrE7.a1:
  • Soil moisture 5(r_sm5)
  • Atmospheric pressure(mv_pres)
  • Soil temperature 5(rr_ts5)
  • Left relative humidity(mv_hum_l)
  • Soil heat flow 5(mv_hft5)
  • Soil moisture 2(r_sm2)
  • Soil temperature 4(rr_ts4)
  • Soil heat flow 4(mv_hft4)
  • Soil moisture 3(r_sm3)
  • Battery(bat)
  • Wind direction (relative to true north)(mv_wind_d)
  • Left air temperature(tair_l)
  • Soil moisture 2(rr_sm2)
  • Right air temperature(tair_r)
  • Soil moisture 5(rr_sm5)
  • Soil moisture 1(r_sm1)
  • Soil moisture 3(rr_sm3)
  • Soil heat flow 1(mv_hft1)
  • Soil moisture 4(r_sm4)
  • Temperature of left humidity sensor chamber(rr_thum_l)
  • Temperature of right humidity sensor chamber(rr_thum_r)
  • Soil moisture 4(rr_sm4)
  • Right relative humidity(mv_hum_r)
  • Soil moisture 1(rr_sm1)
  • Soil temperature 2(rr_ts2)
  • Soil temperature 3(rr_ts3)
  • Soil heat flow 2(mv_hft2)
  • Soil heat flow 3(mv_hft3)
  • Net radiation(mv_q)
  • Home signal(mv_home)
  • Soil temperature 1(rr_ts1)
  • Reference temperature(rr_tref)
  • scalar wind speed(wind_s)

sgp15ebbrE7.b1:
  • soil_moisture_1_rr
  • soil_heat_flow_1_mv
  • soil_temp_4_rr
  • soil_heat_flow_4_mv
  • soil_moisture_3_rr
  • soil_temp_5_rr
  • atmos_pressure_mv
  • rh_right_mv
  • soil_temp_1_rr
  • net_radiation_mv
  • battery_voltage
  • soil_heat_flow_3_mv
  • soil_heat_flow_2_mv
  • soil_moisture_4_rr
  • temp_reference_rr
  • soil_moisture_5_rr
  • temp_air_right
  • temp_trh_right_rr
  • wdir_vec_mean_mv
  • temp_air_left
  • soil_temp_3_rr
  • wspd_arith_mean
  • temp_trh_left_rr
  • home_signal
  • soil_heat_flow_5_mv
  • soil_temp_2_rr
  • rh_left_mv
  • soil_moisture_2_rr

sgp30ebbrE7.b1:
  • corr_soil_heat_flow_5
  • soil_heat_capacity_5
  • soil_moisture_2
  • soil_heat_capacity_4
  • wspd_arith_mean
  • surface_soil_heat_flux_1
  • home_signal_15
  • energy_storage_change_4
  • vapor_pressure_top
  • surface_soil_heat_flux_2
  • soil_moisture_1
  • soil_moisture_3
  • corr_soil_heat_flow_4
  • surface_soil_heat_flux_avg
  • corr_soil_heat_flow_3
  • soil_moisture_5
  • energy_storage_change_5
  • soil_heat_capacity_1
  • vapor_pressure_bottom
  • temp_trh_top
  • sensible_heat_flux
  • soil_moisture_4
  • temp_reference
  • bowen_ratio
  • soil_heat_flow_1
  • Barometric Pressure(atmos_pressure)
  • temp_air_bottom
  • surface_soil_heat_flux_4
  • soil_temp_1
  • home_signal_30
  • soil_temp_4
  • surface_soil_heat_flux_3
  • soil_heat_flow_3
  • soil_temp_2
  • soil_heat_flow_2
  • wdir_vec_mean
  • soil_heat_capacity_2
  • soil_heat_flow_4
  • soil_heat_capacity_3
  • rh_bottom_fraction
  • soil_heat_flow_5
  • soil_temp_5
  • surface_soil_heat_flux_5
  • energy_storage_change_2
  • wspd_vec_mean
  • latent_heat_flux
  • energy_storage_change_3
  • energy_storage_change_1
  • corr_soil_heat_flow_1
  • wdir_vec_std
  • temp_trh_bottom
  • soil_temp_3
  • corr_soil_heat_flow_2
  • rh_top_fraction
  • net_radiation
  • temp_air_top


Back To Table of Contents

DQRID : D030712.13
Start DateStart TimeEnd DateEnd Time
04/22/2003165004/22/20031720
Subject:
SGP/EBBR/E7  - 6 Month Checks
DataStreams:sgp15ebbrE7.a1, sgp15ebbrE7.b1, sgp30ebbrE7.a1, sgp30ebbrE7.b1, sgp5ebbrE7.a1
Description:
Many measurements were incorrect while the AEM was positioned with both aspirators at the 
same height for comparison checks.
Measurements:sgp5ebbrE7.a1:
  • top air temperature(tair_top)
  • bottom vapor pressure(vp_bot)
  • Temperature of bottom humidity sensor chamber(thum_bot)
  • Temperature of the top humidity chamber(thum_top)
  • top vapor pressure(vp_top)
  • Top humidity(hum_top)
  • bottom air temperature(tair_bot)
  • Bottom humidity(hum_bot)

sgp15ebbrE7.a1:
  • Temperature of left humidity sensor chamber(rr_thum_l)
  • Temperature of right humidity sensor chamber(rr_thum_r)
  • Left relative humidity(mv_hum_l)
  • Left air temperature(tair_l)
  • Right air temperature(tair_r)
  • Right relative humidity(mv_hum_r)

sgp30ebbrE7.a1:
  • ratio of sensible/latent heat fluxes (Bowen ratio)(bowen)
  • top air temperature(tair_top)
  • Top humidity(hum_top)
  • top vapor pressure(vp_top)
  • bottom air temperature(tair_bot)
  • bottom vapor pressure(vp_bot)
  • Temperature of bottom humidity sensor chamber(thum_bot)
  • latent heat flux(e)
  • h(h)
  • Bottom humidity(hum_bot)
  • Temperature of the top humidity chamber(thum_top)

sgp15ebbrE7.b1:
  • rh_right_mv
  • temp_air_right
  • temp_trh_left_rr
  • temp_trh_right_rr
  • temp_air_left
  • rh_left_mv

sgp30ebbrE7.b1:
  • temp_air_bottom
  • rh_bottom_fraction
  • latent_heat_flux
  • temp_trh_bottom
  • vapor_pressure_bottom
  • temp_trh_top
  • sensible_heat_flux
  • vapor_pressure_top
  • bowen_ratio
  • rh_top_fraction
  • temp_air_top


Back To Table of Contents

DQRID : D030712.9
Start DateStart TimeEnd DateEnd Time
02/24/2003090003/11/20031800
Subject:
SGP/EBBR/E7  - AEM Hung Inbetween Home Position
DataStreams:sgp15ebbrE7.a1, sgp15ebbrE7.b1, sgp30ebbrE7.a1, sgp30ebbrE7.b1, sgp5ebbrE7.a1
Description:
The AEM was hung inbetween home positions, causing many measurements to be incorrect.
Measurements:sgp5ebbrE7.a1:
  • top air temperature(tair_top)
  • bottom vapor pressure(vp_bot)
  • Temperature of bottom humidity sensor chamber(thum_bot)
  • Temperature of the top humidity chamber(thum_top)
  • top vapor pressure(vp_top)
  • Top humidity(hum_top)
  • bottom air temperature(tair_bot)
  • Bottom humidity(hum_bot)

sgp15ebbrE7.a1:
  • Temperature of left humidity sensor chamber(rr_thum_l)
  • Temperature of right humidity sensor chamber(rr_thum_r)
  • Left relative humidity(mv_hum_l)
  • Left air temperature(tair_l)
  • Right air temperature(tair_r)
  • Right relative humidity(mv_hum_r)

sgp30ebbrE7.a1:
  • ratio of sensible/latent heat fluxes (Bowen ratio)(bowen)
  • top air temperature(tair_top)
  • Top humidity(hum_top)
  • top vapor pressure(vp_top)
  • bottom air temperature(tair_bot)
  • bottom vapor pressure(vp_bot)
  • Temperature of bottom humidity sensor chamber(thum_bot)
  • latent heat flux(e)
  • h(h)
  • Bottom humidity(hum_bot)
  • Temperature of the top humidity chamber(thum_top)

sgp15ebbrE7.b1:
  • rh_right_mv
  • temp_air_right
  • temp_trh_left_rr
  • temp_trh_right_rr
  • temp_air_left
  • rh_left_mv

sgp30ebbrE7.b1:
  • temp_air_bottom
  • rh_bottom_fraction
  • latent_heat_flux
  • temp_trh_bottom
  • vapor_pressure_bottom
  • temp_trh_top
  • sensible_heat_flux
  • vapor_pressure_top
  • bowen_ratio
  • rh_top_fraction
  • temp_air_top


Back To Table of Contents

DQRID : D031211.6
Start DateStart TimeEnd DateEnd Time
03/07/2003150010/12/20032355
Subject:
SGP/EBBR/E7 - Pressure Sensor Data Incorrect
DataStreams:sgp15ebbrE7.b1, sgp30ebbrE7.b1, sgp5ebbrE7.a1
Description:
The E7 pressure sensor suffered
from spikes in pressure, which were related to 
increases in voltage during the day as the 
solar panels charged the battery.  These spikes
were not of a magnitude that would affect the 
30 minute surface fluxes.

Replacement of the pressure sensor solved the problem.
Measurements:sgp5ebbrE7.a1:
  • Retrieved pressure profile(pres)

sgp15ebbrE7.b1:
  • atmos_pressure_mv

sgp30ebbrE7.b1:
  • Barometric Pressure(atmos_pressure)


Back To Table of Contents

DQRID : D050719.6
Start DateStart TimeEnd DateEnd Time
04/01/2001000003/22/20051900
Subject:
SGP/EBBR/E7 - Improved EBBR CR10 Program
DataStreams:sgp30ebbrE7.b1
Description:
Effective 20050322.1900, the EBBR.E7 CR10 program was revised to improve 
the quality of the primary measurements as follows:
   
1) An RMS procedure is used to determine max and min limits of acceptable
soil heat flow.  This is applied to the individual soil sets.  Measurements
outside the limits are rejected and the measurements within the limits are
used to calculate the average soil heat flow.
   
2) Max and min limits are used to determine incorrect values of net
radiation, sensible heat flux (h), latent heat flux (e), and automatic
exchange mechanism (AEM) signal.  If AEM signal is outside the limits, h 
and e are set to 999s.  If net radiation is outside the limits, h and e are 
set to 999s. If h or e are outside the limits, h and e are set to 999s.
   
Virtually no incorrect soil measurement will affect the primary 
measurements of h and e.
   
By setting h and e to 999s, it can be easily seen that the primary 
variables are incorrect; no other interpretation is possible.
   
Prior to 20050322, the improved CR10 program was NOT in effect.  DQRs have
been submitted for known instances of incorrect soil measurements which
affected the quality of the primary measurements of h and e.
   
Note: the DQR begin date is the begin date of the sgp30ebbrE7.b1 data
stream.  The earlier version of the CR10 program was also used on previous
EBBR datastream names (e.g. sgp30ebbrE7.a1).
Measurements:sgp30ebbrE7.b1:
  • surface_soil_heat_flux_avg
  • latent_heat_flux
  • sensible_heat_flux


Back To Table of Contents



END OF DATA