DQR ID | Subject | Data Streams Affected |
---|---|---|
D020129.10 | SGP/EBBR/E13 - Reprocess: E13 EBBR Soil heat Flows #1 and #2 Incorrect | sgp15ebbrE13.a1, sgp15ebbrE13.b1, sgp30ebbrE13.a1, sgp30ebbrE13.b1 |
D020129.13 | SGP EBBR E13 - E13 EBBR Left T/RH Probe Temperature Incorrect | sgp15ebbrE13.a1, sgp15ebbrE13.b1, sgp30ebbrE13.a1, sgp30ebbrE13.b1 |
D020129.2 | SGP EBBR E13 - E13 EBBR AEM in Mid Position | sgp15ebbrE13.a1, sgp15ebbrE13.b1, sgp30ebbrE13.a1, sgp30ebbrE13.b1, sgp5ebbrE13.a1 |
D020129.3 | SGP EBBR E13 - E13 EBBR AEM Home 30 Offset | sgp15ebbrE13.a1, sgp15ebbrE13.b1, sgp30ebbrE13.a1, sgp30ebbrE13.b1, sgp5ebbrE13.a1 |
D020131.13 | SGP/EBBR/E13 - Left T/RH Probe Temperature Incorrect | sgp15ebbrE13.a1, sgp15ebbrE13.b1, sgp30ebbrE13.a1, sgp30ebbrE13.b1, sgp5ebbrE13.a1 |
D020214.1 | SGP/EBBR/E13 - Left Humidity Probe Temperature Incorrect | sgp15ebbrE13.a1, sgp15ebbrE13.b1, sgp30ebbrE13.a1, sgp30ebbrE13.b1, sgp5ebbrE13.a1 |
D020214.2 | SGP/EBBR/E13 - Data incorrect during maintenance | sgp15ebbrE13.a1, sgp15ebbrE13.b1, sgp30ebbrE13.a1, sgp30ebbrE13.b1, sgp5ebbrE13.a1 |
D020214.5 | SGP/EBBR/E13 - Data Incorrect During 6 Month Checks | sgp15ebbrE13.a1, sgp15ebbrE13.b1, sgp30ebbrE13.a1, sgp30ebbrE13.b1, sgp5ebbrE13.a1 |
D020716.12 | SGP/EBBR/E13 - 6 Month Checks | sgp15ebbrE13.a1, sgp15ebbrE13.b1, sgp30ebbrE13.a1, sgp30ebbrE13.b1, sgp5ebbrE13.a1 |
D020717.15 | SGP/EBBR/E13 - Wrong CR10 Program Installed | sgp15ebbrE13.a1, sgp15ebbrE13.b1, sgp30ebbrE13.a1, sgp30ebbrE13.b1, sgp5ebbrE13.00, sgp5ebbrE13.a1 |
D020717.17 | SGP/EBBR/E13 - AEM Hung up | sgp15ebbrE13.a1, sgp15ebbrE13.b1, sgp30ebbrE13.a1, sgp30ebbrE13.b1, sgp5ebbrE13.a1 |
D030110.34 | SGP/EBBR/E13 - Data Incorrect during 6 month checks | sgp15ebbrE13.a1, sgp15ebbrE13.b1, sgp30ebbrE13.a1, sgp30ebbrE13.b1, sgp5ebbrE13.a1 |
D030115.4 | SGP/EBBR/E13 - Wind Speed Stalling at Low Speeds | sgp15ebbrE13.a1, sgp15ebbrE13.b1, sgp30ebbrE13.a1, sgp30ebbrE13.b1, sgp5ebbrE13.a1 |
D030115.6 | SGP/EBBR/E13 - AEM Jung between Home Positions | sgp15ebbrE13.a1, sgp15ebbrE13.b1, sgp30ebbrE13.a1, sgp30ebbrE13.b1, sgp5ebbrE13.a1 |
D030712.17 | SGP/EBBR/E13 - 6 Month Checks | sgp15ebbrE13.a1, sgp15ebbrE13.b1, sgp30ebbrE13.a1, sgp30ebbrE13.b1, sgp5ebbrE13.a1 |
D030919.8 | SGP/EBBR/E13 - Water In Net Radiometer; Surface Fluxes are Incorrect | sgp15ebbrE13.a1, sgp15ebbrE13.b1, sgp30ebbrE13.a1, sgp30ebbrE13.b1, sgp5ebbrE13.a1 |
D031031.5 | SGP/EBBR/E13 - Water in Net Radiometer, Surface Fluxes Incorrect | sgp15ebbrE13.a1, sgp15ebbrE13.b1, sgp30ebbrE13.a1, sgp30ebbrE13.b1, sgp5ebbrE13.a1 |
D031204.10 | SGP/EBBR/E13 - 6 Month Checks | sgp15ebbrE13.b1, sgp30ebbrE13.b1, sgp5ebbrE13.b1 |
D031222.16 | SGP/EBBR/E13 - Wind Speed Sensor Frozen By Ice Storm | sgp15ebbrE13.b1, sgp30ebbrE13.b1, sgp5ebbrE13.b1 |
D031222.17 | SGP/EBBR/E13 - Net Radiometer Iced Over During Storm | sgp15ebbrE13.b1, sgp30ebbrE13.b1, sgp5ebbrE13.b1 |
D040304.12 | SGP/EBBR/E13 - Wind Speed Frozen Stopped By Ice | sgp15ebbrE13.b1, sgp30ebbrE13.b1, sgp5ebbrE13.b1 |
D040608.6 | SGP/EBBR/E13 - Automatic Exchange Mechanism Failure | sgp15ebbrE13.b1, sgp30ebbrE13.b1, sgp5ebbrE13.b1 |
D051111.11 | SGP/EBBR/E13 - metadata corrections | sgp15ebbrE13.b1, sgp30ebbrE13.b1, sgp5ebbrE13.b1 |
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/05/2001 | 1700 | 01/18/2002 | 0001 |
Subject: | SGP/EBBR/E13 - Reprocess: E13 EBBR Soil heat Flows #1 and #2 Incorrect |
DataStreams: | sgp15ebbrE13.a1, sgp15ebbrE13.b1, sgp30ebbrE13.a1, sgp30ebbrE13.b1 |
Description: | Soil Heat Flow probes #1 and #2 were incorrect during the indicated period (and for some time afterward, to be covered in another DQR). Outputs from the probes were typically too large negative or too large positive. |
Measurements: | sgp15ebbrE13.b1:
sgp15ebbrE13.a1:
sgp30ebbrE13.b1:
sgp30ebbrE13.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/12/2001 | 1735 | 10/18/2001 | 1601 |
11/22/2001 | 0130 | 11/25/2001 | 1531 |
01/05/2002 | 1930 | 01/05/2002 | 1931 |
01/06/2002 | 1930 | 01/06/2002 | 2101 |
01/07/2002 | 2330 | 01/07/2002 | 2331 |
01/08/2002 | 1730 | 01/08/2002 | 1801 |
01/09/2002 | 0330 | 01/18/2002 | 0001 |
Subject: | SGP EBBR E13 - E13 EBBR Left T/RH Probe Temperature Incorrect |
DataStreams: | sgp15ebbrE13.a1, sgp15ebbrE13.b1, sgp30ebbrE13.a1, sgp30ebbrE13.b1 |
Description: | The left T/RH Probe Temperature was often incorrect, causing the other indicated measurements to be incorrect also. When the home30 signal had an offset, the top RH probe temperature was incorrect but not the bottom RH probe temperature. |
Measurements: | sgp15ebbrE13.b1:
sgp15ebbrE13.a1:
sgp30ebbrE13.b1:
sgp30ebbrE13.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/09/2001 | 0245 | 10/09/2001 | 2145 |
11/25/2001 | 1545 | 12/28/2001 | 1931 |
Subject: | SGP EBBR E13 - E13 EBBR AEM in Mid Position |
DataStreams: | sgp15ebbrE13.a1, sgp15ebbrE13.b1, sgp30ebbrE13.a1, sgp30ebbrE13.b1, sgp5ebbrE13.a1 |
Description: | The AEM stopped before reaching the end of it's travel, causing the home signals to be between 0 and 3 during much of this period (therefore the data is colored yellow). All gradient data, sensible heat flux, latent heat flux, and the Bowen ratio are incorrect during this condition. |
Measurements: | sgp15ebbrE13.b1:
sgp15ebbrE13.a1:
sgp5ebbrE13.a1:
sgp30ebbrE13.b1:
sgp30ebbrE13.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/12/2001 | 1315 | 11/25/2001 | 1541 |
12/28/2001 | 1930 | 01/18/2002 | 0001 |
Subject: | SGP EBBR E13 - E13 EBBR AEM Home 30 Offset |
DataStreams: | sgp15ebbrE13.a1, sgp15ebbrE13.b1, sgp30ebbrE13.a1, sgp30ebbrE13.b1, sgp5ebbrE13.a1 |
Description: | The AEM home30 signal is offset by approximately 25; it appears that the electronics of the AEM is adding the home15 and home30 voltages together when the AEM is in the home30 position. All gradient data, sensible heat flux, latent heat flux, and the Bowen ratio are incorrect during this condition. |
Measurements: | sgp15ebbrE13.b1:
sgp15ebbrE13.a1:
sgp5ebbrE13.a1:
sgp30ebbrE13.b1:
sgp30ebbrE13.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
11/25/2001 | 1545 | 12/28/2001 | 1931 |
Subject: | SGP/EBBR/E13 - Left T/RH Probe Temperature Incorrect |
DataStreams: | sgp15ebbrE13.a1, sgp15ebbrE13.b1, sgp30ebbrE13.a1, sgp30ebbrE13.b1, sgp5ebbrE13.a1 |
Description: | During much of the indicated period the Left T/RH Temperature was incorrect. Because the home signal was between 0 and 3, the temperature was incorrect when the AEM was at the bottom position, but was correct when the AEM was at the top position. This was caused by a short created when the sensor was mispositioned in the aspirator housing and enough strain on the cable for it to bring it into contact with the housing in the bottom position. |
Measurements: | sgp15ebbrE13.b1:
sgp15ebbrE13.a1:
sgp5ebbrE13.a1:
sgp30ebbrE13.b1:
sgp30ebbrE13.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
01/18/2002 | 0005 | 01/25/2002 | 2201 |
Subject: | SGP/EBBR/E13 - Left Humidity Probe Temperature Incorrect |
DataStreams: | sgp15ebbrE13.a1, sgp15ebbrE13.b1, sgp30ebbrE13.a1, sgp30ebbrE13.b1, sgp5ebbrE13.a1 |
Description: | The left humidity probe temperature was incorrect much of the time, as was the top humidity temperature and vapor pressure. |
Measurements: | sgp15ebbrE13.b1:
sgp15ebbrE13.a1:
sgp5ebbrE13.a1:
sgp30ebbrE13.b1:
sgp30ebbrE13.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
01/25/2002 | 2200 | 01/25/2002 | 2201 |
Subject: | SGP/EBBR/E13 - Data incorrect during maintenance |
DataStreams: | sgp15ebbrE13.a1, sgp15ebbrE13.b1, sgp30ebbrE13.a1, sgp30ebbrE13.b1, sgp5ebbrE13.a1 |
Description: | The 5, 15, and 30 minute measurements were zero or offscale at 2200 GMT only. Electronic connections were being checked at that time. |
Measurements: | sgp15ebbrE13.b1:
sgp15ebbrE13.a1:
sgp5ebbrE13.a1:
sgp30ebbrE13.b1:
sgp30ebbrE13.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
01/25/2002 | 2010 | 01/25/2002 | 2101 |
Subject: | SGP/EBBR/E13 - Data Incorrect During 6 Month Checks |
DataStreams: | sgp15ebbrE13.a1, sgp15ebbrE13.b1, sgp30ebbrE13.a1, sgp30ebbrE13.b1, sgp5ebbrE13.a1 |
Description: | The measurements were incorrect during the 6 month checks. |
Measurements: | sgp15ebbrE13.b1:
sgp15ebbrE13.a1:
sgp5ebbrE13.a1:
sgp30ebbrE13.b1:
sgp30ebbrE13.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
05/16/2002 | 1855 | 05/16/2002 | 1926 |
Subject: | SGP/EBBR/E13 - 6 Month Checks |
DataStreams: | sgp15ebbrE13.a1, sgp15ebbrE13.b1, sgp30ebbrE13.a1, sgp30ebbrE13.b1, sgp5ebbrE13.a1 |
Description: | The indicated measurements were incorrect during the 6 month checks. |
Measurements: | sgp15ebbrE13.b1:
sgp15ebbrE13.a1:
sgp5ebbrE13.a1:
sgp30ebbrE13.b1:
sgp30ebbrE13.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/05/2001 | 1715 | 02/22/2002 | 2131 |
Subject: | SGP/EBBR/E13 - Wrong CR10 Program Installed |
DataStreams: | sgp15ebbrE13.a1, sgp15ebbrE13.b1, sgp30ebbrE13.a1, sgp30ebbrE13.b1, sgp5ebbrE13.00, sgp5ebbrE13.a1 |
Description: | An old version 4 program was installed on 5 Oct 01 instead of the correct version 8 program. All of the indicated measurements are suspect. |
Measurements: | sgp15ebbrE13.b1:
sgp5ebbrE13.00:
sgp15ebbrE13.a1:
sgp5ebbrE13.a1:
sgp30ebbrE13.b1:
sgp30ebbrE13.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
01/18/2002 | 0015 | 03/03/2002 | 0801 |
03/03/2002 | 0815 | 03/08/2002 | 1401 |
03/08/2002 | 1415 | 03/09/2002 | 0931 |
03/09/2002 | 0945 | 03/09/2002 | 2001 |
03/12/2002 | 0000 | 03/12/2002 | 0101 |
03/12/2002 | 0115 | 04/12/2002 | 1901 |
04/16/2002 | 1430 | 04/16/2002 | 2001 |
04/16/2002 | 2230 | 04/17/2002 | 0031 |
04/17/2002 | 1530 | 04/17/2002 | 1701 |
04/17/2002 | 2230 | 04/17/2002 | 2231 |
04/18/2002 | 1230 | 04/18/2002 | 1231 |
05/06/2002 | 0600 | 05/06/2002 | 1931 |
05/07/2002 | 0000 | 05/07/2002 | 0001 |
05/07/2002 | 0300 | 05/07/2002 | 0301 |
05/07/2002 | 0400 | 05/07/2002 | 0401 |
05/07/2002 | 1700 | 05/07/2002 | 1731 |
05/08/2002 | 2300 | 05/09/2002 | 0101 |
05/11/2002 | 1530 | 05/11/2002 | 1601 |
05/11/2002 | 1900 | 05/11/2002 | 1901 |
Subject: | SGP/EBBR/E13 - AEM Hung up |
DataStreams: | sgp15ebbrE13.a1, sgp15ebbrE13.b1, sgp30ebbrE13.a1, sgp30ebbrE13.b1, sgp5ebbrE13.a1 |
Description: | The automatic exchange mechanism hung numerous times, but with various different measurements of home signals. In all cases, temperature and humidity gradients were incorrect; thus the Bowen ratio, sensible heat flux, and latent heat flux are incorrect for the indicated periods. Even when the home 15 and 30 signals were different (but too high) the measurements were incorrect because the program keys off of the home signals, which must be in the proper ranges. |
Measurements: | sgp15ebbrE13.b1:
sgp15ebbrE13.a1:
sgp5ebbrE13.a1:
sgp30ebbrE13.b1:
sgp30ebbrE13.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
11/14/2002 | 2015 | 11/14/2002 | 2045 |
Subject: | SGP/EBBR/E13 - Data Incorrect during 6 month checks |
DataStreams: | sgp15ebbrE13.a1, sgp15ebbrE13.b1, sgp30ebbrE13.a1, sgp30ebbrE13.b1, sgp5ebbrE13.a1 |
Description: | Some of the measurements are incorrect during the 6 month checks. |
Measurements: | sgp15ebbrE13.b1:
sgp15ebbrE13.a1:
sgp5ebbrE13.a1:
sgp30ebbrE13.b1:
sgp30ebbrE13.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
09/23/2002 | 0000 | 10/31/2002 | 2130 |
Subject: | SGP/EBBR/E13 - Wind Speed Stalling at Low Speeds |
DataStreams: | sgp15ebbrE13.a1, sgp15ebbrE13.b1, sgp30ebbrE13.a1, sgp30ebbrE13.b1, sgp5ebbrE13.a1 |
Description: | Perhaps because of excessive bearing wear, the wind speed sensor had a high starting threshhold with wind speeds below about 2 m/s. Wind speed measurements at all speeds were probably too low. |
Measurements: | sgp15ebbrE13.b1:
sgp15ebbrE13.a1:
sgp5ebbrE13.a1:
sgp30ebbrE13.b1:
sgp30ebbrE13.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
09/18/2002 | 1210 | 09/19/2002 | 0245 |
Subject: | SGP/EBBR/E13 - AEM Jung between Home Positions |
DataStreams: | sgp15ebbrE13.a1, sgp15ebbrE13.b1, sgp30ebbrE13.a1, sgp30ebbrE13.b1, sgp5ebbrE13.a1 |
Description: | When the AEM (Automatic Exchange Mechanism) is hung inbetween home positions, the gradients of temperature and relative humidity, and thus sensible and latent heat fluxes, are incorrect. |
Measurements: | sgp15ebbrE13.b1:
sgp15ebbrE13.a1:
sgp5ebbrE13.a1:
sgp30ebbrE13.b1:
sgp30ebbrE13.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
05/01/2003 | 1905 | 05/01/2003 | 1935 |
Subject: | SGP/EBBR/E13 - 6 Month Checks |
DataStreams: | sgp15ebbrE13.a1, sgp15ebbrE13.b1, sgp30ebbrE13.a1, sgp30ebbrE13.b1, sgp5ebbrE13.a1 |
Description: | Many measurements were incorrect while the AEM was positioned with both aspirators at the same height for comparison checks. |
Measurements: | sgp15ebbrE13.b1:
sgp15ebbrE13.a1:
sgp5ebbrE13.a1:
sgp30ebbrE13.b1:
sgp30ebbrE13.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
04/23/2003 | 1830 | 05/01/2003 | 2000 |
Subject: | SGP/EBBR/E13 - Water In Net Radiometer; Surface Fluxes are Incorrect |
DataStreams: | sgp15ebbrE13.a1, sgp15ebbrE13.b1, sgp30ebbrE13.a1, sgp30ebbrE13.b1, sgp5ebbrE13.a1 |
Description: | The net radiometer top dome was punctured by migrating birds. This alone does not cause incorrect net radiation measurements. However, when it subsequently rains, water collects in the bottom dome, causing the net radiation measurements to be too large during the day and too small at night. |
Measurements: | sgp15ebbrE13.b1:
sgp15ebbrE13.a1:
sgp30ebbrE13.b1:
sgp5ebbrE13.a1:
sgp30ebbrE13.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
09/29/2003 | 1800 | 10/02/2003 | 1845 |
Subject: | SGP/EBBR/E13 - Water in Net Radiometer, Surface Fluxes Incorrect |
DataStreams: | sgp15ebbrE13.a1, sgp15ebbrE13.b1, sgp30ebbrE13.a1, sgp30ebbrE13.b1, sgp5ebbrE13.a1 |
Description: | The net radiometer top dome was punctured by migrating birds. This alone does not cause incorrect net radiation measurements. However, when it subsequently rains, water collects in the bottom dome, causing the net radiation measurements to be too large during the day and too small at night. |
Measurements: | sgp15ebbrE13.b1:
sgp15ebbrE13.a1:
sgp30ebbrE13.b1:
sgp5ebbrE13.a1:
sgp30ebbrE13.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/13/2003 | 1830 | 10/13/2003 | 1900 |
Subject: | SGP/EBBR/E13 - 6 Month Checks |
DataStreams: | sgp15ebbrE13.b1, sgp30ebbrE13.b1, sgp5ebbrE13.b1 |
Description: | Many measurements were incorrect while the AEM was positioned with both aspirators at the same height for comparison checks. |
Measurements: | sgp15ebbrE13.b1:
sgp5ebbrE13.b1:
sgp30ebbrE13.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
12/09/2003 | 2145 | 12/10/2003 | 0115 |
Subject: | SGP/EBBR/E13 - Wind Speed Sensor Frozen By Ice Storm |
DataStreams: | sgp15ebbrE13.b1, sgp30ebbrE13.b1, sgp5ebbrE13.b1 |
Description: | The wind speed sensor was frozen stopped by ice from a storm. The wind speed and residual wind speed measurements are incorrect. |
Measurements: | sgp15ebbrE13.b1:
sgp5ebbrE13.b1:
sgp30ebbrE13.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
12/14/2003 | 1730 | 12/14/2003 | 1830 |
Subject: | SGP/EBBR/E13 - Net Radiometer Iced Over During Storm |
DataStreams: | sgp15ebbrE13.b1, sgp30ebbrE13.b1, sgp5ebbrE13.b1 |
Description: | The net radiometer was covered with ice from a storm. Net radiation values are incorrect, and are sometimes even negative during the daytime. Sensible and latent heat fluxes are therefore incorrect. |
Measurements: | sgp15ebbrE13.b1:
sgp5ebbrE13.b1:
sgp30ebbrE13.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
02/09/2004 | 1125 | 02/09/2004 | 1500 |
Subject: | SGP/EBBR/E13 - Wind Speed Frozen Stopped By Ice |
DataStreams: | sgp15ebbrE13.b1, sgp30ebbrE13.b1, sgp5ebbrE13.b1 |
Description: | An ice storm froze the wind speed sensor to a stopped condition. The wind speed and residual wind speed measurements are incorrect. This sensor failure does not affect the sensible and latent heat fluxes. |
Measurements: | sgp15ebbrE13.b1:
sgp5ebbrE13.b1:
sgp30ebbrE13.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
06/05/2004 | 0130 | 07/14/2004 | 1515 |
Subject: | SGP/EBBR/E13 - Automatic Exchange Mechanism Failure |
DataStreams: | sgp15ebbrE13.b1, sgp30ebbrE13.b1, sgp5ebbrE13.b1 |
Description: | The AEM was stuck in the home_15 position or reported near zero home signals during much of the indicated period. The Bowen ratio and latent and sensible heat fluxes were incorrect when the AEM was not operating properly; the periods of incorrect data can be determined from the home signal values. On 7/14/04 the AEM was replaced. |
Measurements: | sgp15ebbrE13.b1:
sgp5ebbrE13.b1:
sgp30ebbrE13.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/13/2003 | 0000 | 07/22/2005 | 2359 |
Subject: | SGP/EBBR/E13 - metadata corrections |
DataStreams: | sgp15ebbrE13.b1, sgp30ebbrE13.b1, sgp5ebbrE13.b1 |
Description: | On 20050723, a series of metadata corrections and additions were completed. These metadata changes apply to all EBBR.E13 data collected by ARM back to the installation of the instrument in September 1992. Please see the current metadata for correct information. These changes do not affect data values or quality. The changes are summarized below: 1) Update of "sensor location" information 2) Addition of installation dates for systems 3) Correction of soil type 4) Correction of soil moisture units (from "by volume" to "gravimetric") |
Measurements: | sgp15ebbrE13.b1:
sgp5ebbrE13.b1:
sgp30ebbrE13.b1:
|