Data Quality Reports for Session: 119960 User: dmfoper Completed: 06/04/2009


TABLE OF CONTENTS

DQR IDSubjectData Streams Affected
D050509.4TWP/MFRSR/C1/C2/C3 - Reprocess: Angstrom Exponent ErrortwpmfrsrlangleyC1.c1, twpmfrsrlangleyC2.c1, twpmfrsrlangleyC3.c1
D060928.3SGP/SONDE/C1 - Increased precision for alt, dp, pres, rh, tdrysgpsondewnpnC1.b1
D060928.4NSA/SONDE/C1 - Increased precision for alt, dp, pres, rh, tdrynsasondewnpnC1.b1


DQRID : D050509.4
Start DateStart TimeEnd DateEnd Time
05/01/2002000011/17/20042359
Subject:
TWP/MFRSR/C1/C2/C3 - Reprocess: Angstrom Exponent Error
DataStreams:twpmfrsrlangleyC1.c1, twpmfrsrlangleyC2.c1, twpmfrsrlangleyC3.c1
Description:
The data used to calculate the angstrom exponent was incorrect.  These
fields should not be used.  All other fields are considered good.
Measurements:twpmfrsrlangleyC1.c1:
  • Angstrom exponent(barnard_angstrom_exponent)
  • Angstrom exponent(michalsky_angstrom_exponent)

twpmfrsrlangleyC2.c1:
  • Angstrom exponent(barnard_angstrom_exponent)
  • Angstrom exponent(michalsky_angstrom_exponent)

twpmfrsrlangleyC3.c1:
  • Angstrom exponent(michalsky_angstrom_exponent)
  • Angstrom exponent(barnard_angstrom_exponent)


Back To Table of Contents

DQRID : D060928.3
Start DateStart TimeEnd DateEnd Time
09/28/2006172812/31/99992359
Subject:
SGP/SONDE/C1 - Increased precision for alt, dp, pres, rh, tdry
DataStreams:sgpsondewnpnC1.b1
Description:
The output precision of the following variables was increased 20060928

alt  changed from 1m to 0.1m
dp   changed from 0.1degC to 0.01degC
pres changed from 0.1 hPa to 0.01 hPa
RH   changed from 1%RH to 0.01%RH
tdry changed from .1degC to 0.01degC

Note that the increase in precision does not necessarily imply an increase in accuracy.  
Users are cautioned to continue to use their best scientific judgement when using these or 
any other data.
Measurements:sgpsondewnpnC1.b1:
  • Surface dew point temperature(dp)
  • Dry bulb temperature(tdry)
  • Relative humidity inside the instrument enclosure(rh)
  • Retrieved pressure profile(pres)
  • Dummy altitude for Zeb(alt)


Back To Table of Contents

DQRID : D060928.4
Start DateStart TimeEnd DateEnd Time
09/29/2006050012/31/99992359
Subject:
NSA/SONDE/C1 - Increased precision for alt, dp, pres, rh, tdry
DataStreams:nsasondewnpnC1.b1
Description:
The output precision of the following variables was increased 20060929:

   alt	changed from 1m to 0.1m
   dp	changed from 0.1degC to 0.01degC
   pres changed from 0.1 hPa to 0.01 hPa
   RH	changed from 1%RH to 0.01%RH
   tdry changed from .1degC to 0.01degC

Note that the increase in precision does not necessarily imply an increase
in accuracy.  Users are cautioned to continue to use their best scientific
judgement when using these or any other data.
Measurements:nsasondewnpnC1.b1:
  • Relative humidity inside the instrument enclosure(rh)
  • Dry bulb temperature(tdry)
  • Dummy altitude for Zeb(alt)
  • Retrieved pressure profile(pres)
  • Surface dew point temperature(dp)


Back To Table of Contents



END OF DATA