DQR ID | Subject | Data Streams Affected |
---|---|---|
D050111.1 | SGP/PGS/C1 - Incorrect 60m Data | sgppgsC1.b1 |
D051118.1 | SGP/PGS/C1 - Suspicious 4m data | sgppgsC1.b1 |
D051118.2 | SGP/PGS/C1 - Suspicious 2m data | sgppgsC1.b1 |
D051118.3 | SGP/PGS/C1 - Suspicious 25m and 60m data | sgppgsC1.b1 |
D051118.4 | SGP/PGS/C1 - Updated files | sgppgsC1.b1 |
Start Date | Start Time | End Date | End Time |
---|---|---|---|
01/05/2005 | 0853 | 01/07/2005 | 2026 |
Subject: | SGP/PGS/C1 - Incorrect 60m Data |
DataStreams: | sgppgsC1.b1 |
Description: | Precise Gas system (PGS) data at 60m (channel 4) are incorrect. This problem is due to a freezing rain and ice storm that hit SGP Central facility on January 5, 2005. The 60m tower inlet was clogged with ice and consequently, no air was supplied to the PGS instrument. |
Measurements: | sgppgsC1.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
11/24/2004 | 0000 | 08/19/2005 | 0100 |
Subject: | SGP/PGS/C1 - Suspicious 4m data |
DataStreams: | sgppgsC1.b1 |
Description: | KNF pump for 4m height (channel 2) started to leak on November 24, 2004 and sampled air was consequently "contaminated" by indoor air. The pump was replaced on August 19, 2005. |
Measurements: | sgppgsC1.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
07/22/2004 | 0000 | 08/19/2005 | 0100 |
Subject: | SGP/PGS/C1 - Suspicious 2m data |
DataStreams: | sgppgsC1.b1 |
Description: | KNF pump for 2m height (channel 1) started to leak on July 22, 2004 and sampled air was consequently "contaminated" by indoor air. The pump was replaced on August 19, 2005. |
Measurements: | sgppgsC1.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
03/31/2005 | 0000 | 08/19/2005 | 0100 |
Subject: | SGP/PGS/C1 - Suspicious 25m and 60m data |
DataStreams: | sgppgsC1.b1 |
Description: | KNF pumps for 25m and 60m height (channel 3 and channel 4) started to leak on March 31, 2005 and sampled air was consequently "contaminated" by indoor air. The pumps were replaced on August 19, 2005. |
Measurements: | sgppgsC1.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
04/11/2001 | 1156 | 10/31/2005 | 2359 |
Subject: | SGP/PGS/C1 - Updated files |
DataStreams: | sgppgsC1.b1 |
Description: | Dew point temperature (dpt) sensor (Vaisala DMT 142) was added to the system on May 24, 2005 to assess water trapping system efficiency. Consequently, variable "dpt" is filled with missing values (-999.99) prior measurements start date (May 24, 2005). |
Measurements: | sgppgsC1.b1:
|