DQR ID | Subject | Data Streams Affected |
---|---|---|
D070203.3 | TWP/TSI/C2 - hazy image | twptsicldmaskC2.a1, twptsimovieC2.a1, twptsiskycoverC2.b1, twptsiskyimageC2.a1 |
D080108.3 | TWP/TSI/C2 - Mirror continuously rotating | twptsicldmaskC2.a1, twptsimovieC2.a1, twptsiskycoverC2.b1, twptsiskyimageC2.a1 |
Start Date | Start Time | End Date | End Time |
---|---|---|---|
01/11/2007 | 1900 | 02/13/2007 | 0447 |
Subject: | TWP/TSI/C2 - hazy image |
DataStreams: | twptsicldmaskC2.a1, twptsimovieC2.a1, twptsiskycoverC2.b1, twptsiskyimageC2.a1 |
Description: | Condensation in the camera lens and/or filter caused the sky images to be "hazy". The desiccant in the main enclosure was changed and the neutral density filter was cleaned. |
Measurements: | twptsicldmaskC2.a1:
twptsiskycoverC2.b1:
twptsiskyimageC2.a1:
twptsimovieC2.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
12/20/2007 | 1849 | 03/05/2008 | 0200 |
Subject: | TWP/TSI/C2 - Mirror continuously rotating |
DataStreams: | twptsicldmaskC2.a1, twptsimovieC2.a1, twptsiskycoverC2.b1, twptsiskyimageC2.a1 |
Description: | The mirror began to continuously spin. Diagnostics were performed on the encoder, control board, and Ethernet adaptor. The instrument was removed on 1/2/2008 and shipped to Darwin for repair. The encoder and control board were replaced and the instrument was reinstalled. |
Measurements: | twptsicldmaskC2.a1:
twptsiskycoverC2.b1:
twptsiskyimageC2.a1:
twptsimovieC2.a1:
|