DQR ID | Subject | Data Streams Affected |
---|---|---|
D040416.1 | TWP/GNDRAD/C3 - IRT bias | twpgndrad60sC3.b1 |
D050221.2 | TWP/GNDRAD/C3 - IRT bias | twpgndrad60sC3.b1 |
D050221.3 | TWP/GNDRAD/C3 - Reprocess: IRT with wrong calibration | twpgndrad60sC3.b1 |
D050919.4 | TWP/GNDRAD/C3 - Tower inverted for instrument testing and replacement | twpgndrad60sC3.b1 |
D051206.5 | TWP/GNDRAD/C3 - IRT malfunction | twpgndrad60sC3.b1 |
D060111.1 | TWP/GNDRAD/C3 - IRT power | twpgndrad60sC3.b1 |
D060509.1 | TWP/GNDRAD/C3 - IRT failed | twpgndrad60sC3.b1 |
D060630.36 | TWP/GNDRAD/C3 - Reprocess: Longwave Calibration error | twpgndrad60sC3.b1 |
D060823.1 | TWP/GNDRAD/C3 - IRT bias | twpgndrad60sC3.b1 |
D080121.2 | TWP/GNDRAD/C3 - Gndrad shutdown for tropical cylone | twpgndrad20sC3.a0, twpgndrad20sC3.a1, twpgndrad60sC3.b1, twpgndradC3.00 |
Start Date | Start Time | End Date | End Time |
---|---|---|---|
04/07/2004 | 0230 | 04/08/2004 | 1200 |
04/12/2004 | 0600 | 04/27/2004 | 1400 |
05/08/2004 | 0300 | 05/15/2004 | 2200 |
05/27/2004 | 1100 | 06/09/2004 | 0000 |
12/29/2004 | 1100 | 01/06/2005 | 2300 |
Subject: | TWP/GNDRAD/C3 - IRT bias |
DataStreams: | twpgndrad60sC3.b1 |
Description: | The IRT behaved erratically, jumping frequently from reporting about 50 Wm^(-2) higher than the PIR for surface irradiance values to about 100Wm^(-2) lower than the PIR. Generally, the IRT measured lower surface temperatures than expected from the PIR. |
Measurements: | twpgndrad60sC3.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
06/10/2004 | 0700 | 12/25/2004 | 0300 |
Subject: | TWP/GNDRAD/C3 - IRT bias |
DataStreams: | twpgndrad60sC3.b1 |
Description: | The IRT measured higher surface temperatures than expected from the PIR, even at night. |
Measurements: | twpgndrad60sC3.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
11/17/2004 | 0000 | 11/19/2004 | 0105 |
Subject: | TWP/GNDRAD/C3 - Reprocess: IRT with wrong calibration |
DataStreams: | twpgndrad60sC3.b1 |
Description: | A spare IRT was installed that was not configured properly. |
Measurements: | twpgndrad60sC3.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
08/05/2005 | 0030 | 08/05/2005 | 0200 |
08/09/2005 | 0000 | 08/09/2005 | 0200 |
Subject: | TWP/GNDRAD/C3 - Tower inverted for instrument testing and replacement |
DataStreams: | twpgndrad60sC3.b1 |
Description: | The tower at Darwin was brought down to test and replace the Gndrad PIR on 8/5/2005 and the PSP on 8/9/2005 |
Measurements: | twpgndrad60sC3.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
11/21/2005 | 1500 | 12/05/2005 | 0100 |
Subject: | TWP/GNDRAD/C3 - IRT malfunction |
DataStreams: | twpgndrad60sC3.b1 |
Description: | The internal IRT power supply failed (probably due to a lightning strike on 11/14) and was drawing excessive current on the data logger's DC system. The problem was corrected by replacing the instrument with a spare. |
Measurements: | twpgndrad60sC3.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
12/20/2005 | 2330 | 01/02/2006 | 2300 |
Subject: | TWP/GNDRAD/C3 - IRT power |
DataStreams: | twpgndrad60sC3.b1 |
Description: | The IRT failed to report after a planned power outage to add lightning protection modules to the AC power wiring. The problem was corrected when a loose power connection to the logger was found, rectified, and power restored to the logger. |
Measurements: | twpgndrad60sC3.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
04/07/2006 | 0000 | 05/18/2006 | 2359 |
Subject: | TWP/GNDRAD/C3 - IRT failed |
DataStreams: | twpgndrad60sC3.b1 |
Description: | The IRT began to fail on 4/7/2006 and failed completely (apparently due to the internal power supply) on 4/27. It was replaced on 5/18. |
Measurements: | twpgndrad60sC3.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
05/20/2004 | 0100 | 12/21/2005 | 2137 |
Subject: | TWP/GNDRAD/C3 - Reprocess: Longwave Calibration error |
DataStreams: | twpgndrad60sC3.b1 |
Description: | Modified pyrgeometer calibration procedures were implemented beginning in December 2003. These modified procedures introduced a calibration bias in the longwave data. The previous procedures were re-implemented at all sites between December 2005 and February 2006 to restore proper calibrations. The data collected while the incorrect procedures were in place are being reprocessing to remove the calibration bias. Note, this also affected standard deviation, maximum and minimum data fields. |
Measurements: | twpgndrad60sC3.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
05/19/2006 | 0000 | 06/27/2006 | 0344 |
Subject: | TWP/GNDRAD/C3 - IRT bias |
DataStreams: | twpgndrad60sC3.b1 |
Description: | The IRT reported higher surface temperatures than the PIR due to corrosion on the terminals of the lightning protection module and a ground wire error. The corrosion was cleaned and the wiring corrected. |
Measurements: | twpgndrad60sC3.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
01/03/2008 | 1000 | 01/07/2008 | 0515 |
Subject: | TWP/GNDRAD/C3 - Gndrad shutdown for tropical cylone |
DataStreams: | twpgndrad20sC3.a0, twpgndrad20sC3.a1, twpgndrad60sC3.b1, twpgndradC3.00 |
Description: | On Jan 3rd approximately 1000GMT the effects of a tropical cyclone started affecting the installed radiometer measurements at ARM/TWP/C3(Darwin) - both Skyrad and Gndrad. On Jan 4th 0740 GMT the Gndrad station was shutdown to avoid damage due to the close passing of this storm. Station was restarted Jan 7th 0515GMT. |
Measurements: | twpgndrad20sC3.a1:
twpgndrad20sC3.a0:
twpgndrad60sC3.b1:
twpgndradC3.00:
|