DQR ID | Subject | Data Streams Affected |
---|---|---|
D040707.1 | SGP/ECOR/E6 - Sonic Sensor failure | sgp30ecorE6.b1, sgpecorE6.00 |
D041202.1 | SGP/ECOR/E6 - Reprocess: Incorrect wind direction | sgp30ecorE6.b1 |
D050222.1 | SGP/ECOR/E6 - Reprocess: Incorrectly flagged (marked as "bad") H2O/CO2 data | sgp30ecorE6.b1 |
D050524.1 | SGP/ECOR/E6 - Missing data | sgp30ecorE6.b1 |
D050524.3 | SGP/ECOR/E6 - Sonic Sensor failure | sgp30ecorE6.b1 |
D050912.5 | SGP/ECOR/E6 - Reprocess: Time Was 7 Hours Slow | sgp30ecorE6.b1 |
D051101.10 | SGP/ECOR/E6 - CO2 and H2O Fluxes and Means Incorrect | sgp30ecorE6.b1 |
Start Date | Start Time | End Date | End Time |
---|---|---|---|
07/05/2004 | 2230 | 08/23/2004 | 1200 |
Subject: | SGP/ECOR/E6 - Sonic Sensor failure |
DataStreams: | sgp30ecorE6.b1, sgpecorE6.00 |
Description: | Due to sonic sensor failure, humidity, CO2 concentration, latent heat flux, and CO2 flux data are incorrect. |
Measurements: | sgpecorE6.00:
sgp30ecorE6.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
08/26/2004 | 1530 | 12/16/2004 | 1630 |
Subject: | SGP/ECOR/E6 - Reprocess: Incorrect wind direction |
DataStreams: | sgp30ecorE6.b1 |
Description: | The sonic anemometer was mounted 90 degrees off during August 26 Corrective Maintenance visit; the wind direction was reported 90 degrees off for the period of August 26, 2004, 15:30 to December 16, 2004, 16:30. |
Measurements: | sgp30ecorE6.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
06/14/2004 | 0000 | 06/14/2004 | 0030 |
Subject: | SGP/ECOR/E6 - Reprocess: Incorrectly flagged (marked as "bad") H2O/CO2 data |
DataStreams: | sgp30ecorE6.b1 |
Description: | Due to system clock instability on ECOR computers their system time is adjusted approximately once per hour; sometimes this adjustment leads to backward time jumps over midnight, into the previous day. In this case all the data based on CO2/H2O measurements might be erroneously marked as bad. Below is a list of times when that might have happen. SITE YEAR MONTH DAY HOUR MINUTE 06 2004 06 14 00 00 |
Measurements: | sgp30ecorE6.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
08/23/2004 | 1230 | 08/26/2004 | 1530 |
01/05/2005 | 0330 | 01/13/2005 | 1600 |
Subject: | SGP/ECOR/E6 - Missing data |
DataStreams: | sgp30ecorE6.b1 |
Description: | Data are missing and unrecoverable. |
Measurements: | sgp30ecorE6.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
07/05/2004 | 2230 | 08/23/2004 | 1200 |
Subject: | SGP/ECOR/E6 - Sonic Sensor failure |
DataStreams: | sgp30ecorE6.b1 |
Description: | Due to sonic sensor failure, wind, temperature and sensible heat flux data are suspect. |
Measurements: | sgp30ecorE6.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
08/11/2005 | 0900 | 09/22/2005 | 1540 |
Subject: | SGP/ECOR/E6 - Reprocess: Time Was 7 Hours Slow |
DataStreams: | sgp30ecorE6.b1 |
Description: | When the site computer was changed on 8/11, the time was set 7 hours behind the correct time. This will be corrected by future reprocessing of the data. |
Measurements: | sgp30ecorE6.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
08/30/2005 | 1930 | 09/13/2005 | 0700 |
Subject: | SGP/ECOR/E6 - CO2 and H2O Fluxes and Means Incorrect |
DataStreams: | sgp30ecorE6.b1 |
Description: | The CO2 and H2O (lv_e) fluxes and means were incorrect during the period because the LI-7500 was not working. |
Measurements: | sgp30ecorE6.b1:
|