DQR ID | Subject | Data Streams Affected |
---|---|---|
D040525.3 | SGP/EBBR/E19 - Metadata errors | sgp15ebbrE19.b1, sgp30baebbrE19.c1, sgp30ebbrE19.b1 |
D050117.10 | SGP/EBBR/E19 - BA EBBR VAP Bulk Aerodynamics | sgp30baebbrE19.c1 |
Start Date | Start Time | End Date | End Time |
---|---|---|---|
05/30/1997 | 0000 | 05/06/2003 | 2359 |
Subject: | SGP/EBBR/E19 - Metadata errors |
DataStreams: | sgp15ebbrE19.b1, sgp30baebbrE19.c1, sgp30ebbrE19.b1 |
Description: | The latitude, longitude and altitude of the El Reno (E19) site were incorrectly entered into the ARM database. The correct location of the EBBR.E19 instrument is: Lat: 35.557N Lon: 98.017W Alt: 421m |
Measurements: | sgp15ebbrE19.b1:
sgp30ebbrE19.b1:
sgp30baebbrE19.c1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
05/30/1997 | 1000 | 06/30/2003 | 2359 |
Subject: | SGP/EBBR/E19 - BA EBBR VAP Bulk Aerodynamics |
DataStreams: | sgp30baebbrE19.c1 |
Description: | Fixed AEM and wind speed sensor heights were improperly used in the calculation of bulk aerodynamic sensible and latent heat fluxes instead of site specific heights. This resulted in either under-estimation or over-estimation of the sensible and latent heat fluxes. |
Measurements: | sgp30baebbrE19.c1:
|