Data Quality Reports for Session: 129861 User: wlj Completed: 08/19/2010


TABLE OF CONTENTS

DQR IDSubjectData Streams Affected
D000210.1SGP/EBBR/E26 - Temperature from Left T/RH Probe Incorrectsgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
D000210.3SGP/EBBR - EBBR E22 Moved, Data Missing/Incorrectsgp15ebbrE22.b1, sgp30ebbrE22.b1, sgp5ebbrE22.b1
D000210.4SGP/EBBR - EBBR E22 Net Radiation Incorrectsgp15ebbrE22.b1, sgp30ebbrE22.b1, sgp5ebbrE22.b1
D000211.1SGP/EBBR - EBBR E25 Data Missing/Incorrect During System Changeoutsgp15ebbrE25.b1, sgp30ebbrE25.b1, sgp5ebbrE25.b1
D000211.13SGP/EBBR/E26 - Left T/RH Probe Temperature Data Incorrectsgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
D000211.8SGP/EBBR - EBBR E25 Data Incorrect During J-panel Changesgp15ebbrE25.b1, sgp30ebbrE25.b1, sgp5ebbrE25.b1
D000211.9SGP/EBBR - EBBR E25 Thermocouple Temperatures Incorrectsgp15ebbrE25.b1, sgp30ebbrE25.b1, sgp5ebbrE25.b1
D000221.3SGP/EBBR/E26 - Right Aspirator Not Workingsgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
D000221.7SGP/EBBR/E26 - Anemometer Not Working, Wind Speed Incorrectsgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
D000225.1SGP/EBBR/26 - Low Battery Conditionsgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
D000301.11SGP/EBBR - EBBR E22 Soil Moistures Negativesgp15ebbrE22.b1, sgp30ebbrE22.b1
D000301.5SGP/EBBR - EBBR E25 Net Radiation Incorrectsgp15ebbrE25.b1, sgp30ebbrE25.b1, sgp5ebbrE25.b1
D000301.9SGP/EBBR/E26 - Net Radiation Incorrectsgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
D000302.2SGP/EBBR - EBBR E22 Soil Moistures Negativesgp15ebbrE22.b1, sgp30ebbrE22.b1
D000307.10SGP/EBBR - EBBR E25 Soil Heat Flow #1 Incorrectsgp15ebbrE25.b1, sgp30ebbrE25.b1
D000307.11SGP/EBBR - EBBR E25 Soil Heat Flow #1 Incorrectsgp15ebbrE25.b1, sgp30ebbrE25.b1
D000307.12SGP/EBBR - EBBR E25 Soil Heat Flow #1 Incorrectsgp15ebbrE25.b1, sgp30ebbrE25.b1
D000307.13SGP/EBBR - EBBR E25 Soil Heat Flow #1 Incorrectsgp15ebbrE25.b1, sgp30ebbrE25.b1
D000307.14SGP/EBBR - EBBR E25 Soil Heat Flow #1 Incorrectsgp15ebbrE25.b1, sgp30ebbrE25.b1
D000307.15SGP/EBBR - EBBR E25 Soil Heat Flow #1 Incorrectsgp15ebbrE25.b1, sgp30ebbrE25.b1
D000307.16SGP/EBBR - EBBR E25 Soil Heat Flow #1 Incorrectsgp15ebbrE25.b1, sgp30ebbrE25.b1
D000307.17SGP/EBBR - EBBR E25 Soil Heat Flow #1 Incorrectsgp15ebbrE25.b1, sgp30ebbrE25.b1
D000307.18SGP/EBBR - EBBR E25 Soil Heat Flow #1 Incorrectsgp15ebbrE25.b1, sgp30ebbrE25.b1
D000307.2SGP/EBBR - EBBR E25 Soil Heat Flow #1 Incorrectsgp15ebbrE25.b1, sgp30ebbrE25.b1
D000307.5SGP/EBBR - EBBR E25 Soil Heat Flow #1 Incorrectsgp15ebbrE25.b1, sgp30ebbrE25.b1
D000307.6SGP/EBBR - EBBR E25 Soil Heat Flow #1 Incorrectsgp15ebbrE25.b1, sgp30ebbrE25.b1
D000307.7SGP/EBBR - EBBR E25 Soil Heat Flow #1 Incorrectsgp15ebbrE25.b1, sgp30ebbrE25.b1
D000307.8SGP/EBBR - EBBR E25 Soil Heat Flow #1 Incorrectsgp15ebbrE25.b1, sgp30ebbrE25.b1
D000307.9SGP/EBBR - EBBR E25 Soil Heat Flow #1 Incorrectsgp15ebbrE25.b1, sgp30ebbrE25.b1
D000622.1SGP/EBBR/E26 - Reprocess Soil Moisture Off-Scalesgp15ebbrE26.b1, sgp30ebbrE26.b1
D000623.1SGP/EBBR/E26 - EBBR E26 Left Aspirator Not Workingsgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
D000623.10SGP/EBBR/E26 - EBBR E26 All Data Incorrectsgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
D000623.11SGP/EBBR/E26 - All Data Incorrectsgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
D000623.2SGP/EBBR/E26 - All Data Incorrectsgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
D000623.3SGP/EBBR/E26 - Low Battery Voltage Causes Incorrect Datasgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
D000623.5SGP/EBBR/E26 - Low Battery Voltage Causes Incorrect Datasgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
D000623.6SGP/EBBR/E26 - Low Battery Voltage Causes Incorrect Datasgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
D000623.7SGP/EBBR/E26 - Low Battery Voltage Causes Incorrect Datasgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
D000623.8SGP/EBBR/E26 - All Data Incorrectsgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
D000623.9SGP/EBBR/E26 - All Data Incorrectsgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
D000627.10SGP/EBBR/E26 - Left Air Temperature Periodically Incorrectsgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
D000627.11SGP/EBBR/E26 - Reference Temperature Incorrectsgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
D000627.4SGP/EBBR/E26 - Electronics Problemsgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
D000627.6SGP/EBBR/E26 - Soil Heat Flow #5 Incorrectsgp15ebbrE26.b1, sgp30ebbrE26.b1
D000627.7SGP/EBBR/E26 - Soil Heat Flow #1 Incorrectsgp15ebbrE26.b1, sgp30ebbrE26.b1
D000627.8SGP/EBBR/E26 - Soil Heat Flow #2 Large Negativesgp15ebbrE26.b1, sgp30ebbrE26.b1
D000627.9SGP/EBBR/E26 - Left Air Temperature Incorrectsgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
D010213.10SGP/EBBR/E25 - EBBR E25 Wind Speed Icedsgp15ebbrE25.b1, sgp30ebbrE25.b1, sgp5ebbrE25.b1
D010213.11SGP/EBBR/E25 - EBBR E25 Wind Speed Icedsgp15ebbrE25.b1, sgp30ebbrE25.b1, sgp5ebbrE25.b1
D010213.12SGP/EBBR/E26 - Wind Speed Icedsgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
D010213.8SGP/EBBR/E22 - EBBR E22 Wind Speed Icedsgp15ebbrE22.b1, sgp30ebbrE22.b1, sgp5ebbrE22.b1
D010213.9SGP/EBBR/E25 - EBBR E25 Wind Speed Icedsgp15ebbrE25.b1, sgp30ebbrE25.b1, sgp5ebbrE25.b1
D010427.11SGP EBBR E22 - E22 EBBR Data Incorrect During Logger Replacementsgp15ebbrE22.b1, sgp30ebbrE22.b1, sgp5ebbrE22.00, sgp5ebbrE22.b1
D010427.13SGP EBBR E22 - E22 EBBR Soil Moisture Lower Than Measurement Capabilitysgp15ebbrE22.b1, sgp30ebbrE22.b1
D010427.14SGP EBBR E22 - E22 EBBR Soil Moisture #3 Lower Than Can Be Measuredsgp15ebbrE22.b1, sgp30ebbrE22.b1
D010427.15SGP EBBR E22 - E22 EBBR Net Radiation Incorrectsgp15ebbrE22.b1, sgp30ebbrE22.b1, sgp5ebbrE22.b1
D010605.16SGP EBBR E25 - E25 EBBR Soil Heat Flow #5 Incorrectsgp15ebbrE25.b1, sgp30ebbrE25.b1
D010605.17SGP EBBR E25 - E25 EBBR Soil Heat Flow #3 Incorrectsgp15ebbrE25.b1, sgp30ebbrE25.b1
D010605.18SGP EBBR E25 - E25 EBBR Left Aspirator Not Workingsgp15ebbrE25.b1, sgp30ebbrE25.b1, sgp5ebbrE25.b1
D010605.19SGP EBBR E25 - E25 EBBR Soil Heat Flow #1 Incorrectsgp15ebbrE25.b1, sgp30ebbrE25.b1
D010605.20SGP EBBR E26 - Data Suspect, Low Battery Voltagesgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.00, sgp5ebbrE26.b1
D010605.22SGP EBBR E26 - All Data Incorrectsgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.00, sgp5ebbrE26.b1
D010605.23SGP EBBR E26 - Soil Heat Flow #1 Incorrectsgp15ebbrE26.b1, sgp30ebbrE26.b1
D010605.24SGP EBBR E26 - Soil Heat Flow #2 Incorrectsgp15ebbrE26.b1, sgp30ebbrE26.b1
D010605.25SGP EBBR E26 - Soil Heat Flow #3 Incorrectsgp15ebbrE26.b1, sgp30ebbrE26.b1
D010723.3SGP EBBR E26 - Soil Moisture #1 Incorrectsgp15ebbrE26.b1, sgp30ebbrE26.b1
D010723.4SGP EBBR E26 - AEM Inbetween, Data Incorrectsgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
D010723.5SGP EBBR E26 - Soil Heat Flow #5 Incorrectsgp15ebbrE26.b1, sgp30ebbrE26.b1
D010723.7SGP EBBR E26 - Some Data Incorrectsgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
D010723.8SGP EBBR E26 - Some Data Incorrectsgp30ebbrE26.b1
D011127.32SGP EBBR E22 - E22 EBBR Data Incorrect During 6 Month Checkssgp15ebbrE22.b1, sgp30ebbrE22.b1, sgp5ebbrE22.b1
D011127.33SGP EBBR E25 - E25 EBBR Data Incorrect During 6 Month Checkssgp15ebbrE25.b1, sgp30ebbrE25.b1, sgp5ebbrE25.b1
D011127.34SGP EBBR E26 - Data Incorrect During 6 Month Checkssgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
D011206.1SGP EBBR E26 - Low Battery Voltagesgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
D011206.11SGP EBBR E25 - E25 EBBR Wind Direction Incorrectsgp30ebbrE25.b1, sgp5ebbrE25.b1
D011206.12SGP EBBR E25 - E25 EBBR Wind Direction Incorrectsgp30ebbrE25.b1, sgp5ebbrE25.b1
D011206.2SGP EBBR E26 - Battery Voltage Lowsgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
D011206.4SGP EBBR E22 - E22 EBBR 30 Minute Data Incorrect After Missing Datasgp30ebbrE22.b1
D011206.6SGP EBBR E25 - E25 EBBR Soil Heat Flow #3 Incorrectsgp15ebbrE25.b1, sgp30ebbrE25.b1
D011206.7SGP EBBR E25 - E25 EBBR Soil Heat Flow #1 Incorrectsgp15ebbrE25.b1, sgp30ebbrE25.b1
D011206.8SGP EBBR E25 - E25 EBBR Soil Heat Flow #3 Incorrectsgp15ebbrE25.b1, sgp30ebbrE25.b1
D011206.9SGP EBBR E25 - E25 EBBR Soil Heat Flow #1 Incorrectsgp15ebbrE25.b1, sgp30ebbrE25.b1
D020628.19SGP/EBBR/E22 - T/RH Checksgp15ebbrE22.b1, sgp30ebbrE22.b1, sgp5ebbrE22.b1
D020628.5SGP/EBBR/E22 - 3-month Checksgp15ebbrE22.b1, sgp30ebbrE22.b1, sgp5ebbrE22.b1
D020628.6SGP/EBBR/E26 - 3-month Checksgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
D020716.17SGP/EBBR/E22 - 6 Month Checkssgp15ebbrE22.b1, sgp30ebbrE22.b1, sgp5ebbrE22.b1
D020716.18SGP/EBBR/E26 - 6 Month Checkssgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
D020716.3SGP/EBBR/E22 - Annual Calibration Changeoutsgp15ebbrE22.b1, sgp30ebbrE22.b1, sgp5ebbrE22.b1
D020717.34SGP/EBBR/E22 - All Measurements Zerosgp15ebbrE22.b1, sgp30ebbrE22.b1, sgp5ebbrE22.00, sgp5ebbrE22.b1
D020717.35SGP/EBBR/E22 - AEM Hung or High Home Signalssgp15ebbrE22.b1, sgp30ebbrE22.b1, sgp5ebbrE22.b1
D020717.36SGP/EBBR/E25 - Reprocess: Soil Heat Flow #5 Negative Offsetsgp30ebbrE25.b1
D020717.37SGP/EBBR/E26 - Measurements Zerosgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.00, sgp5ebbrE26.b1
D020717.38SGP/EBBR/E26 - Measurements Incorrectsgp30ebbrE26.b1
D020717.39SGP/EBBR/E26 - Multiplexer 2 Failure From High Temperaturesgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
D020724.48SGP/EBBR/E26 - Annual Calibration Changeoutsgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
D021113.1SGP/EBBR - Incorrect Units for Soil Heat Capacity (cs1, cs2, cs3, cs4, cs5) in 30EBBR
Header
sgp30ebbrE12.b1, sgp30ebbrE13.b1, sgp30ebbrE15.b1, sgp30ebbrE18.b1, sgp30ebbrE19.b1,
sgp30ebbrE2.b1, sgp30ebbrE20.b1, sgp30ebbrE22.b1, sgp30ebbrE26.b1, sgp30ebbrE4.b1,
sgp30ebbrE7.b1, sgp30ebbrE8.b1, sgp30ebbrE9.b1
D021113.4SGP/EBBR - Incorrect Units for Soil Heat Capacity (cs1, cs2, cs3, cs4, cs5) in 30EBBR
Header
sgp30ebbrE12.b1, sgp30ebbrE13.b1, sgp30ebbrE15.b1, sgp30ebbrE20.b1, sgp30ebbrE22.b1,
sgp30ebbrE26.b1, sgp30ebbrE4.b1, sgp30ebbrE7.b1, sgp30ebbrE8.b1, sgp30ebbrE9.b1
D030110.26SGP/EBBR/E22 - Data Incorrect during 6 month checkssgp15ebbrE22.b1, sgp30ebbrE22.b1, sgp5ebbrE22.b1
D030110.27SGP/EBBR/E26 - Data Incorrect during 6 month checkssgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
D030117.16SGP/EBBR/E22 - AEM Hung between home positionssgp15ebbrE22.b1, sgp30ebbrE22.b1, sgp5ebbrE22.b1
D030117.17SGP/EBBR/E22 - Water inside Broken Net Rad Domesgp30ebbrE22.b1, sgp5ebbrE22.b1
D030117.26SGP/EBBR/E26 - Measurements zero following logger restartsgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
D030117.27SGP/EBBR/E26 - Multiplexer Problemsgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
D030117.28SGP/EBBR/E26 - Water in broken Net Radiometer Domesgp30ebbrE26.b1, sgp5ebbrE26.b1
D030117.29SGP/EBBR/E26 - Battery Voltage Lowsgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
D030128.2SGP/EBBR/E26 - AEM Hungsgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
D030128.3SGP/EBBR/E26 - Data zeros following logger restartsgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
D030128.4SGP/EBBR/E26 - Left Air Temperature Incorrectsgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
D030514.8SGP/EBBR/E26 - E26 EBBR Soil Heat Flow #1 Incorrectsgp15ebbrE26.b1, sgp30ebbrE26.b1
D030530.3SGP/EBBR/E27 - E27 EBBR Incorrect Units for Soil Heat Capacity (cs1, cs2, cs3, cs4, cs5)
in 30EBBR
sgp30ebbrE27.b1
D030709.1SGP/EBBR/E25 - Incorrect Units for Soil Heat Capacity (cs1, cs2, cs3, cs4, cs5) in 30EBBR
Header
sgp30ebbrE25.b1
D030709.4SGP/EBBR/E25 - Incorrect Units for Soil Heat Capacity (cs1, cs2, cs3, cs4, cs5) in 30EBBR
Header
sgp30baebbrE25.c1, sgp30ebbrE25.b1
D030711.2SGP/EBBR/E27 - Soil Heat Flow #2 Incorrectsgp15ebbrE27.b1, sgp30ebbrE27.b1
D030711.3SGP/EBBR/E27 - Soil Heat Flow #4 Incorrectsgp15ebbrE27.b1, sgp30ebbrE27.b1
D030711.4SGP/EBBR/E27 - Reference T Sensor Failuresgp15ebbrE27.b1, sgp30ebbrE27.b1, sgp5ebbrE27.b1
D030711.5SGP/EBBR/E27 - Wind Direction Hungsgp15ebbrE27.b1, sgp30ebbrE27.b1, sgp5ebbrE27.b1
D030711.6SGP/EBBR/E26 -Right Air Temperature Incorrectsgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
D030711.7SGP/EBBR/E22 - home30 too largesgp15ebbrE22.b1, sgp30ebbrE22.b1, sgp5ebbrE22.b1
D030712.22SGP/EBBR/E22 - 6 Month Checkssgp15ebbrE22.b1, sgp30ebbrE22.b1, sgp5ebbrE22.b1
D030712.23SGP/EBBR/E26 - 6 Month Checkssgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
D030712.24SGP/EBBR/E27 - 6 Month Checkssgp15ebbrE27.b1, sgp30ebbrE27.b1, sgp5ebbrE27.b1
D030728.4SGP/EBBR/E26 - Soil Heat Flow #5 Large Positivesgp15ebbrE26.b1, sgp30ebbrE26.b1
D030728.5SGP/EBBR/E27 - Soil Heat Flow #1 Largesgp15ebbrE27.b1, sgp30ebbrE27.b1
D030728.6SGP/EBBR/E27 - Incorrect Data From Logger Restartsgp30ebbrE27.b1
D030729.4SGP/EBBR/E22 - AEM Hung Inbetween Home Positionssgp15ebbrE22.b1, sgp30ebbrE22.b1, sgp5ebbrE22.b1
D030916.2SGP/EBBR/E22 - AEM Home Signals Too Highsgp30ebbrE22.b1, sgp5ebbrE22.b1
D030919.11SGP/EBBR/E26 - Soil Storage Incorrect; Surface Fluxes Incorrectsgp30ebbrE26.b1
D030919.12SGP/EBBR/E27 - Water in Net Radiometer; Surface Fluxes are Incorrectsgp15ebbrE27.b1, sgp30ebbrE27.b1, sgp5ebbrE27.b1
D030919.13SGP/EBBR/E27 - 15 and 30 Minute Data All Zerossgp15ebbrE27.b1, sgp30ebbrE27.b1
D030922.7SGP/EBBR/E27 - Right Air Temperature Spiked Offscalesgp15ebbrE27.b1, sgp30ebbrE27.b1, sgp5ebbrE27.b1
D031021.3SGP/EBBR/E27 - Missing data during system updatesgp15ebbrE27.b1, sgp30ebbrE27.b1, sgp5ebbrE27.b1
D031031.8SGP/EBBR/E22 - Water in Net Radiometer, Surface Fluxes Incorrectsgp15ebbrE22.b1, sgp30ebbrE22.b1, sgp5ebbrE22.b1
D031103.1SGP/EBBR/E26 - AEM Home Signals Incorrect, Surface Fluxes Incorrectsgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
D031117.3SGP/EBBR/E27 - Right Air Temperature Spiked Offscalesgp15ebbrE27.b1, sgp30ebbrE27.b1, sgp5ebbrE27.b1
D031204.20SGP/EBBR/E22 - 6 Month Checkssgp15ebbrE22.b1, sgp30ebbrE22.b1, sgp5ebbrE22.b1
D031204.21SGP/EBBR/E26 - 6 Month Checkssgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
D031204.22SGP/EBBR/E27 - 6 Month Checkssgp15ebbrE27.b1, sgp30ebbrE27.b1, sgp5ebbrE27.b1
D031210.1SGP/EBBR/E27 - Reprocess: Soil Heat Flow #5 Offscale, Surface Fluxes Incorrectsgp15ebbrE27.b1, sgp30ebbrE27.b1
D031211.3SGP/EBBR/E26 - Spark Gap Bad, Pressure Incorrectsgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
D031222.21SGP/EBBR/E22 - Wind Speed Sensor Frozen By Ice Stormsgp15ebbrE22.b1, sgp30ebbrE22.b1, sgp5ebbrE22.b1
D031222.22SGP/EBBR/E22 - Wind Direction Sensor Frozen By Ice Stormsgp15ebbrE22.b1, sgp30ebbrE22.b1, sgp5ebbrE22.b1
D031222.24SGP/EBBR/E26 - Wind Speed Sensor Frozen By Ice Stormsgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
D031222.25SGP/EBBR/E26 - Wind Direction Sensor Frozen By Ice Stormsgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
D031222.26SGP/EBBR/E27 - Soil Temperature #3 Spike in Datasgp15ebbrE27.b1, sgp30ebbrE27.b1
D040303.2SGP/EBBR/E22 - Wind Speed Sensor Bearings Wornsgp15ebbrE22.b1, sgp30ebbrE22.b1, sgp5ebbrE22.b1
D040304.21SGP/EBBR/E22 - Wind Speed Frozen Stopped By Icesgp15ebbrE22.b1, sgp30ebbrE22.b1, sgp5ebbrE22.b1
D040304.22SGP/EBBR/E22 - Wind Direction Frozen Stopped By Icesgp30ebbrE22.b1, sgp5ebbrE22.b1
D040304.25SGP/EBBR/E27 - Wind Speed Frozen Stopped By Icesgp15ebbrE27.b1, sgp30ebbrE27.b1, sgp5ebbrE27.b1
D040304.28SGP/EBBR/E26 - Wind Speed Frozen Stopped By Icesgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
D040304.29SGP/EBBR/E26 - Wind Direction Frozen Stopped By Icesgp30ebbrE26.b1, sgp5ebbrE26.b1
D040318.13SGP/EBBR/E27 - Soil Moisture #5 Insensitivesgp30ebbrE27.b1
D040507.3SGP/EBBR/E27 - Right Air Temperature Incorrectsgp15ebbrE27.b1, sgp30ebbrE27.b1, sgp5ebbrE27.b1
D040706.2SGP/EBBR/E22 - Net Radiation Incorrectsgp30ebbrE22.b1, sgp5ebbrE22.b1
D040706.3SGP/EBBR/E27 - Loose Tair Left Connectionssgp15ebbrE27.b1, sgp30ebbrE27.b1, sgp5ebbrE27.b1
D040723.3SGP/EBBR/E22 - Water In Net Radiometersgp30ebbrE22.b1, sgp5ebbrE22.b1
D040813.2SGP/EBBR/E20 - AEM Failuresgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1
D040813.5SGP/EBBR/E26 - Soil Temperature #4 and Soil Heat Flow #4 Incorrectsgp30ebbrE26.b1
D040915.7SGP/EBBR/E20 - Soil Heat Flow #3 and Soil Temperature #3 Incorrectsgp15ebbrE20.b1, sgp30ebbrE20.b1
D041006.3SGP/EBBR/E20 - All Soil Measurements Incorrectsgp15ebbrE20.b1, sgp30ebbrE20.b1
D041222.1SGP/EBBR/E26 - Spark Gap Bad, Pressure Incorrectsgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
D041222.16SGP/EBBR/E20 - 6 Month Checkssgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1
D041222.17SGP/EBBR/E22 - 6 Month Checkssgp15ebbrE22.b1, sgp30ebbrE22.b1, sgp5ebbrE22.b1
D041222.18SGP/EBBR/E26 - 6 Month Checkssgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
D041222.19SGP/EBBR/E27 - 6 Month Checkssgp15ebbrE27.b1, sgp30ebbrE27.b1, sgp5ebbrE27.b1
D041222.3SGP/EBBR/E20 - Soil Moisture #4 and Soil Temperature #4 Incorrectsgp15ebbrE20.b1, sgp30ebbrE20.b1
D041222.4SGP/EBBR/E26 - Low Battery Voltage - Many Measurements Incorrectsgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
D041222.5SGP/EBBR/E26 - Most Measurements Incorrectsgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
D041223.1SGP/EBBR/E20 - Soil Heat Flow #4 Incorrectsgp15ebbrE20.b1, sgp30ebbrE20.b1
D050206.14SGP/EBBR/E20 - Wind Speed Frozen Stopped By Ice Stormsgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1
D050206.15SGP/EBBR/E22 - Wind Speed Frozen Stopped By Ice Stormsgp15ebbrE22.b1, sgp30ebbrE22.b1, sgp5ebbrE22.b1
D050206.16SGP/EBBR/E26 - Wind Speed Frozen Stopped By Ice Stormsgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
D050206.17SGP/EBBR/E27 - Wind Speed Frozen Stopped By Ice Stormsgp15ebbrE27.b1, sgp30ebbrE27.b1, sgp5ebbrE27.b1
D050207.10SGP/EBBR/E20 - Wind Direction Frozen Stopped By Ice Stormsgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1
D050207.11SGP/EBBR/E22 - Wind Direction Frozen Stopped By Ice Stormsgp15ebbrE22.b1, sgp30ebbrE22.b1, sgp5ebbrE22.b1
D050207.12SGP/EBBR/E26 - Wind Direction Frozen Stopped By Ice Stormsgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
D050207.13SGP/EBBR/E27 - Wind Direction Frozen Stopped By Ice Stormsgp15ebbrE27.b1, sgp30ebbrE27.b1, sgp5ebbrE27.b1
D050211.1SGP/EBBR/E26 - Aging Pressure Sensor Output Changes With Supply Voltagesgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
D050211.2SGP/EBBR/E27 - Soil Moisture #5 Incorrectsgp30ebbrE27.b1
D050215.21SGP/EBBR/E22 - Wind Speed Frozen Stopped By Icesgp15ebbrE22.b1, sgp30ebbrE22.b1, sgp5ebbrE22.b1
D050215.22SGP/EBBR/E22 - Wind Direction Frozen Stopped By Icesgp15ebbrE22.b1, sgp30ebbrE22.b1, sgp5ebbrE22.b1
D050323.2SGP/EBBR/E22 - Net Radiation Too Low - Top Dome Brokensgp15ebbrE22.b1, sgp30ebbrE22.b1, sgp5ebbrE22.b1
D050324.3SGP/EBBR/E26 - Incorrect soil type coefficients usedsgp30ebbrE26.b1
D050404.1SGP/EBBR/E20 - Wrong Datalogger Program Installedsgp30ebbrE20.b1
D050404.4SGP/EBBR/E20 - Temp. of thum_left Incorrect At Timessgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1
D050413.6SGP/EBBR/E27 - SM2 Coefficients Incorectsgp15ebbrE27.b1, sgp30ebbrE27.b1
D050719.13SGP/EBBR/E20 - Improved EBBR CR10 Programsgp30ebbrE20.b1
D050719.14SGP/EBBR/E22 - Improved EBBR CR10 Programsgp30ebbrE22.b1
D050719.15SGP/EBBR/E26 - Improved EBBR CR10 Programsgp30ebbrE26.b1
D050719.16SGP/EBBR/E27 - Improved EBBR CR10 Programsgp30ebbrE27.b1
D050922.2SGP/EBBR/E20 - Soil Temperature and Soil Moisture #4 Measurements Incorrectsgp15ebbrE20.b1, sgp30ebbrE20.b1
D051106.13SGP/EBBR/E22 - Net Radiation Incorrect; Sensible and Latent Heat Fluxes Incorrectsgp15ebbrE22.b1, sgp30ebbrE22.b1, sgp5ebbrE22.b1
D051106.15SGP/EBBR/E27 - Net Radiation Incorrect; Sensible and Latent Heat Fluxes Incorrectsgp15ebbrE27.b1, sgp30ebbrE27.b1, sgp5ebbrE27.b1
D051106.16SGP/EBBR/E27 - Net Radiation Incorrect; Sensible and Latent Heat Fluxes Incorredtsgp15ebbrE27.b1, sgp30ebbrE27.b1, sgp5ebbrE27.b1
D051106.28SGP/EBBR/E20 - Average Soil Heat Flux Incorrectsgp30ebbrE20.b1
D051106.29SGP/EBBR/E22 - Average Soil Heat Flux Incorrectsgp30ebbrE22.b1
D051106.30SGP/EBBR/E26 - Average Soil Heat Flux Incorrectsgp30ebbrE26.b1
D051106.31SGP/EBBR/E27 - Average Soil Heat Flux Incorrectsgp30ebbrE27.b1
D051112.10SGP/EBBR/E27 - metadata correctionssgp15ebbrE27.b1, sgp30ebbrE27.b1, sgp5ebbrE27.b1
D051112.7SGP/EBBR/E20 - metadata correctionssgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1
D051112.8SGP/EBBR/E22 - metadata correctionssgp15ebbrE22.b1, sgp30ebbrE22.b1, sgp5ebbrE22.b1
D051112.9SGP/EBBR/E26 - metadata correctionssgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
D051115.10SGP/EBBR/E25 - metadata errorssgp15ebbrE25.b1, sgp30ebbrE25.b1
D051222.1SGP/EBBR/E26 - Data Suspect During Low Supply Voltagesgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
D060111.13SGP/EBBR/E20 - Data Incorrect During J-Panel Replacementsgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1
D060112.1SGP/EBBR/E22 - Sensible and Latent Heat Fluxes Incorrectsgp15ebbrE22.b1, sgp30ebbrE22.b1, sgp5ebbrE22.b1
D060425.1SGP/EBBR/E27 - Sensible and Latent Heat Fluxes Incorrectsgp15ebbrE27.b1, sgp30ebbrE27.b1, sgp5ebbrE27.b1
D060428.4SGP/EBBR/E22 - Fluxes Incorrect When Soil Heat Flow #3 Out of Rangesgp30ebbrE22.b1
D060501.22SGP/EBBR/E20 - Suspect Measurementssgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1
D060501.25SGP/EBBR/E22 - Wind Speed Sensor Frozen Stoppedsgp15ebbrE22.b1, sgp30ebbrE22.b1, sgp5ebbrE22.b1
D060501.26SGP/EBBR/E26 - Measurements Incorrectsgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
D060501.27SGP/EBBR/E27 - Flux and Gradient Measurements Incorrectsgp15ebbrE27.b1, sgp30ebbrE27.b1, sgp5ebbrE27.b1
D060508.3SGP/EBBR/E27 - Instrument problem, Loose connectionssgp15ebbrE27.b1, sgp30ebbrE27.b1
D060622.6SGP/EBBR/E20 - Net Radiation, Fluxes Too Largesgp30ebbrE20.b1, sgp5ebbrE20.b1
D060712.1SGP/EBBR/E27 - Field fire burned AEMsgp15ebbrE27.b1, sgp30ebbrE27.b1, sgp5ebbrE27.b1
D060809.1SGP/EBBR/E27 - Sensible, Latent, and Average Soil Heat Fluxes Sometimes Incorrectsgp15ebbrE27.b1, sgp30ebbrE27.b1
D060809.2SGP/EBBR/E27 - Low Battery Conditionsgp15ebbrE27.b1, sgp30ebbrE27.b1, sgp5ebbrE27.b1
D060818.11SGP/EBBR/E27 - Most Measurements Suspectsgp15ebbrE27.b1, sgp30ebbrE27.b1, sgp5ebbrE27.b1
D060818.13SGP/EBBR/E27 - Battery Voltage Problem - Measurements Incorrectsgp15ebbrE27.b1, sgp30ebbrE27.b1, sgp5ebbrE27.b1
D060921.8SGP/EBBR/E22 - Net Radiation and Sensible and Latent Heat Fluxes Incorrectsgp15ebbrE22.b1, sgp30ebbrE22.b1, sgp5ebbrE22.b1
D061106.5SGP/EBBR/E22 - Soil Heat Flow #4 Incorrect - Sensible and Latent Heat Fluxes Sometimes
Affected
sgp15ebbrE22.b1, sgp30ebbrE22.b1
D070426.1SGP/EBBR/E22 - Wind Direction Incorrectsgp15ebbrE22.b1, sgp30ebbrE22.b1, sgp5ebbrE22.b1
D070716.2SGP/EBBR/E20 - Reprocess: Wind Direction 20 Degrees Lowsgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1
D070809.1SGP/EBBR/E27 - Multiplexer #2 failuresgp15ebbrE27.b1, sgp30ebbrE27.b1, sgp5ebbrE27.b1
D070815.6SGP/EBBR/E22 - H and LE Incorrectsgp15ebbrE22.b1, sgp30ebbrE22.b1
D071001.1SGP/EBBR/E26 - Sensible and Latent Heat Fluxes Affected by bad temp sensorsgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
D071115.1SGP/EBBR/E20 - Reprocess: Wind Direction 65 Degrees Lowsgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1
D080114.3SGP/EBBR/E27 - Measurements offscalesgp15ebbrE27.b1, sgp30ebbrE27.b1, sgp5ebbrE27.b1
D080410.2SGP/EBBR/E20 - Wind Direction 50 Degrees Highsgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1
D080902.1SGP/EBBR/E20 - Wind Direction Incorrectsgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1
D090313.16SGP/EBBR/E20 - Wind Speed Incorrectsgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1
D090313.6SGP/EBBR/E22 - Wind Speed Incorrectsgp15ebbrE22.b1, sgp30ebbrE22.b1, sgp5ebbrE22.b1
D090313.8SGP/EBBR/E26 - Wind Speed Incorrectsgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
D090313.9SGP/EBBR/E27 - Wind Speed Incorrectsgp15ebbrE27.b1, sgp30ebbrE27.b1, sgp5ebbrE27.b1
D090414.1SGP/EBBR/E20 - Wind Direction Incorrectsgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1


DQRID : D000210.1
Start DateStart TimeEnd DateEnd Time
06/11/1999000006/29/19992145
Subject:
SGP/EBBR/E26 - Temperature from Left T/RH Probe Incorrect
DataStreams:sgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
Description:
The temperature from the left T/RH probe went offscale frequently.  This
temperature is used in the calculation of the vapor pressure.  Therefore,
top and bottom Thum measurements, left Thum, top and bottom vapor pressure 
measurements, vapor pressure gradients, and the resulting latent and 
sensible heat fluxes and bowen ratio were frequently incorrect for the 
period stated.
Measurements:sgp30ebbrE26.b1:
  • vapor_pressure_bottom
  • temp_trh_top
  • bowen_ratio
  • latent_heat_flux
  • temp_trh_bottom
  • vapor_pressure_top
  • sensible_heat_flux

sgp15ebbrE26.b1:
  • temp_trh_left_rr

sgp5ebbrE26.b1:
  • temp_trh_top
  • temp_trh_bottom
  • vapor_pressure_bottom
  • vapor_pressure_top


Back To Table of Contents

DQRID : D000210.3
Start DateStart TimeEnd DateEnd Time
10/29/1999141511/02/19992030
Subject:
SGP/EBBR - EBBR E22 Moved, Data Missing/Incorrect
DataStreams:sgp15ebbrE22.b1, sgp30ebbrE22.b1, sgp5ebbrE22.b1
Description:
During, and as a consequence of, the relocation of E22 EBBR, some data
is missing or incorrect during the period above.  The data was 
sneakernetted on 3 Nov 99, so some of the data may have been recovered.
Some of the data during the period is incorrect as a consequence of
damage done by cattle during the period; inspection of the data is
required to determine incorrect data.
Measurements:sgp30ebbrE22.b1:
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_1
  • corr_soil_heat_flow_4
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_5
  • base time(base_time)
  • vapor_pressure_top
  • sensible_heat_flux
  • temp_reference
  • wspd_arith_mean
  • temp_air_bottom
  • surface_soil_heat_flux_avg
  • lat(lat)
  • temp_trh_top
  • Dummy altitude for Zeb(alt)
  • wspd_vec_mean
  • lon(lon)
  • energy_storage_change_1
  • vapor_pressure_bottom
  • home_signal_30
  • latent_heat_flux
  • temp_trh_bottom
  • rh_bottom_fraction
  • bowen_ratio
  • soil_moisture_5
  • net_radiation
  • soil_moisture_1
  • soil_moisture_2
  • soil_moisture_3
  • soil_moisture_4
  • soil_heat_capacity_5
  • soil_heat_capacity_4
  • soil_heat_flow_2
  • soil_heat_capacity_3
  • soil_heat_flow_3
  • soil_heat_capacity_2
  • soil_heat_capacity_1
  • soil_heat_flow_1
  • energy_storage_change_3
  • energy_storage_change_2
  • energy_storage_change_5
  • energy_storage_change_4
  • home_signal_15
  • Time offset of tweaks from base_time(time_offset)
  • wdir_vec_std
  • soil_heat_flow_5
  • soil_heat_flow_4
  • soil_temp_5
  • soil_temp_2
  • soil_temp_1
  • soil_temp_4
  • soil_temp_3
  • wdir_vec_mean
  • temp_air_top
  • Barometric Pressure(atmos_pressure)
  • rh_top_fraction
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_1
  • surface_soil_heat_flux_4
  • surface_soil_heat_flux_3
  • surface_soil_heat_flux_5

sgp5ebbrE22.b1:
  • vapor_pressure_bottom
  • temp_trh_top
  • lat(lat)
  • net_radiation
  • rh_bottom_fraction
  • temp_trh_bottom
  • base time(base_time)
  • home_signal
  • wspd_arith_mean
  • temp_reference
  • wdir_vec_std
  • Time offset of tweaks from base_time(time_offset)
  • wspd_vec_mean
  • lon(lon)
  • vapor_pressure_top
  • wdir_vec_mean
  • Dummy altitude for Zeb(alt)
  • temp_air_top
  • rh_top_fraction
  • Barometric Pressure(atmos_pressure)
  • temp_air_bottom

sgp15ebbrE22.b1:
  • battery_voltage
  • temp_trh_right_rr
  • Dummy altitude for Zeb(alt)
  • rh_right_mv
  • atmos_pressure_mv
  • temp_air_left
  • soil_heat_flow_3_mv
  • home_signal
  • base time(base_time)
  • lon(lon)
  • net_radiation_mv
  • temp_reference_rr
  • soil_temp_2_rr
  • soil_temp_1_rr
  • Time offset of tweaks from base_time(time_offset)
  • soil_temp_4_rr
  • soil_moisture_2_r
  • temp_air_right
  • soil_moisture_4_r
  • soil_moisture_3_r
  • soil_moisture_5_r
  • wdir_vec_mean_mv
  • rh_left_mv
  • soil_heat_flow_2_mv
  • wspd_arith_mean
  • soil_heat_flow_5_mv
  • soil_temp_3_rr
  • soil_moisture_1_r
  • soil_heat_flow_4_mv
  • lat(lat)
  • soil_heat_flow_1_mv
  • temp_trh_left_rr
  • soil_temp_5_rr


Back To Table of Contents

DQRID : D000210.4
Start DateStart TimeEnd DateEnd Time
10/29/1999143011/03/19991930
Subject:
SGP/EBBR - EBBR E22 Net Radiation Incorrect
DataStreams:sgp15ebbrE22.b1, sgp30ebbrE22.b1, sgp5ebbrE22.b1
Description:
The upper dome of the net radiometer was broken, probably by migrating
birds, and water had drained into the bottom dome.  Since much of the data
is missing during the period, it is not clear exactly when the top dome was
broken during the period.  All net radiation data and sensible and latent 
heat fluxes data are incorrect for this period.

The affected data fields are:

5 minute:  q

15 minute: mv_q

30 minute: q, e, h
Measurements:sgp30ebbrE22.b1:
  • latent_heat_flux
  • sensible_heat_flux
  • net_radiation

sgp5ebbrE22.b1:
  • net_radiation

sgp15ebbrE22.b1:
  • net_radiation_mv


Back To Table of Contents

DQRID : D000211.1
Start DateStart TimeEnd DateEnd Time
10/25/1999143010/25/19991845
Subject:
SGP/EBBR - EBBR E25 Data Missing/Incorrect During System Changeout
DataStreams:sgp15ebbrE25.b1, sgp30ebbrE25.b1, sgp5ebbrE25.b1
Description:
All data was missing or incorrect during the EBBR system changeout.
Measurements:sgp30ebbrE25.b1:
  • wspd_vec_mean
  • net_radiation
  • rh_bottom_fraction
  • temp_trh_bottom
  • wspd_arith_mean
  • Time offset of tweaks from base_time(time_offset)
  • home_signal_15
  • wdir_vec_mean
  • Barometric Pressure(atmos_pressure)
  • energy_storage_change_5
  • Dummy altitude for Zeb(alt)
  • temp_trh_top
  • energy_storage_change_4
  • energy_storage_change_3
  • energy_storage_change_2
  • energy_storage_change_1
  • home_signal_30
  • vapor_pressure_bottom
  • bowen_ratio
  • lat(lat)
  • soil_heat_capacity_4
  • soil_heat_capacity_3
  • soil_heat_capacity_2
  • soil_heat_capacity_1
  • temp_air_top
  • sensible_heat_flux
  • lon(lon)
  • surface_soil_heat_flux_4
  • surface_soil_heat_flux_5
  • corr_soil_heat_flow_5
  • corr_soil_heat_flow_4
  • surface_soil_heat_flux_1
  • corr_soil_heat_flow_3
  • base time(base_time)
  • corr_soil_heat_flow_2
  • surface_soil_heat_flux_3
  • corr_soil_heat_flow_1
  • surface_soil_heat_flux_2
  • temp_reference
  • soil_moisture_1
  • soil_moisture_2
  • soil_moisture_3
  • soil_moisture_4
  • wdir_vec_std
  • soil_moisture_5
  • soil_heat_capacity_5
  • rh_top_fraction
  • soil_temp_1
  • soil_temp_2
  • soil_temp_3
  • soil_temp_4
  • soil_temp_5
  • latent_heat_flux
  • soil_heat_flow_1
  • soil_heat_flow_2
  • soil_heat_flow_3
  • soil_heat_flow_4
  • soil_heat_flow_5
  • vapor_pressure_top
  • temp_air_bottom
  • surface_soil_heat_flux_avg

sgp5ebbrE25.b1:
  • Barometric Pressure(atmos_pressure)
  • base time(base_time)
  • wspd_arith_mean
  • wdir_vec_std
  • Dummy altitude for Zeb(alt)
  • net_radiation
  • temp_air_top
  • Time offset of tweaks from base_time(time_offset)
  • wdir_vec_mean
  • rh_top_fraction
  • wspd_vec_mean
  • temp_trh_bottom
  • temp_reference
  • vapor_pressure_bottom
  • lat(lat)
  • vapor_pressure_top
  • home_signal
  • rh_bottom_fraction
  • temp_trh_top
  • lon(lon)
  • temp_air_bottom

sgp15ebbrE25.b1:
  • soil_temp_4_rr
  • rh_left_mv
  • lat(lat)
  • soil_heat_flow_2_mv
  • Time offset of tweaks from base_time(time_offset)
  • soil_heat_flow_4_mv
  • soil_heat_flow_5_mv
  • atmos_pressure_mv
  • temp_air_left
  • soil_heat_flow_1_mv
  • wdir_vec_mean_mv
  • temp_reference_rr
  • soil_temp_5_rr
  • soil_moisture_3_r
  • soil_moisture_1_r
  • soil_moisture_4_r
  • soil_moisture_5_r
  • soil_heat_flow_3_mv
  • temp_air_right
  • net_radiation_mv
  • temp_trh_left_rr
  • soil_moisture_2_r
  • base time(base_time)
  • rh_right_mv
  • soil_temp_1_rr
  • wspd_arith_mean
  • lon(lon)
  • soil_temp_2_rr
  • home_signal
  • temp_trh_right_rr
  • Dummy altitude for Zeb(alt)
  • soil_temp_3_rr
  • battery_voltage


Back To Table of Contents

DQRID : D000211.13
Start DateStart TimeEnd DateEnd Time
06/11/1999000006/29/19992145
Subject:
SGP/EBBR/E26 - Left T/RH Probe Temperature Data Incorrect
DataStreams:sgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
Description:
Left T/RH probe temperature is frequently offscale during the period.
Examine the data (compare with the the T/RH right temperature) to determine
which times are incorrect.  Replacement of the probe on 29 June 1999 
solved the problem.

Affected data are:

5 minute:  tair_bot, tair_top
15 minute: tair_l
30 minute: tair_bot, tair_top, e, h, bowen
Measurements:sgp30ebbrE26.b1:
  • temp_air_bottom
  • bowen_ratio
  • latent_heat_flux
  • temp_air_top
  • sensible_heat_flux

sgp15ebbrE26.b1:
  • temp_air_left

sgp5ebbrE26.b1:
  • temp_air_top
  • temp_air_bottom


Back To Table of Contents

DQRID : D000211.8
Start DateStart TimeEnd DateEnd Time
06/16/1999191506/16/19992000
Subject:
SGP/EBBR - EBBR E25 Data Incorrect During J-panel Change
DataStreams:sgp15ebbrE25.b1, sgp30ebbrE25.b1, sgp5ebbrE25.b1
Description:
Some data was incorrect during the replacement of the J-panel #4. 

Affected data are:

5 minute:  tair_top, tair_bot, thum_top, thum_bot, vp_top, vp_bot, tref
15 minute: rr_thum_r, rr_thum_l, rr_ts1, rr_ts2, rr_ts3, rr_ts4, rr_ts5,
           r_sm1, r_sm2, r_sm3, r_sm4, r_sm5, tair_r, tair_l, r_tref
30 minute: bowen, e, h, tair_top, tair_bot, thum_top, thum_bot, vp_top, 
           vp_bot, sm1, sm2, sm3, sm4, sm5, shf1, shf2, shf3, shf4, shf5,
           c_shf1, c_shf2, c_shf3, c_shf4, c_shf5, ts1, ts2, ts3, ts4, ts5,
           cs1, cs2, cs3, cs4, cs5, ces1, ces2, ces3, ces4, ces5, g1, g2,
           g3, g4, g5, ave_shf, tref
Measurements:sgp30ebbrE25.b1:
  • soil_heat_capacity_4
  • soil_heat_capacity_3
  • soil_heat_capacity_2
  • soil_heat_capacity_1
  • temp_air_top
  • sensible_heat_flux
  • temp_trh_bottom
  • surface_soil_heat_flux_4
  • surface_soil_heat_flux_5
  • corr_soil_heat_flow_5
  • corr_soil_heat_flow_4
  • surface_soil_heat_flux_1
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_2
  • surface_soil_heat_flux_3
  • corr_soil_heat_flow_1
  • surface_soil_heat_flux_2
  • temp_reference
  • soil_moisture_1
  • soil_moisture_2
  • soil_moisture_3
  • soil_moisture_4
  • soil_moisture_5
  • soil_heat_capacity_5
  • soil_temp_1
  • soil_temp_2
  • soil_temp_3
  • soil_temp_4
  • soil_temp_5
  • energy_storage_change_5
  • latent_heat_flux
  • soil_heat_flow_1
  • soil_heat_flow_2
  • soil_heat_flow_3
  • soil_heat_flow_4
  • soil_heat_flow_5
  • temp_trh_top
  • vapor_pressure_top
  • temp_air_bottom
  • energy_storage_change_4
  • energy_storage_change_3
  • energy_storage_change_2
  • energy_storage_change_1
  • vapor_pressure_bottom
  • bowen_ratio
  • surface_soil_heat_flux_avg

sgp5ebbrE25.b1:
  • temp_trh_bottom
  • temp_reference
  • vapor_pressure_bottom
  • vapor_pressure_top
  • temp_trh_top
  • temp_air_bottom
  • temp_air_top

sgp15ebbrE25.b1:
  • temp_air_right
  • soil_temp_4_rr
  • temp_trh_left_rr
  • soil_moisture_2_r
  • soil_temp_1_rr
  • temp_air_left
  • soil_temp_2_rr
  • temp_trh_right_rr
  • temp_reference_rr
  • soil_temp_5_rr
  • soil_temp_3_rr
  • soil_moisture_3_r
  • soil_moisture_1_r
  • soil_moisture_4_r
  • soil_moisture_5_r


Back To Table of Contents

DQRID : D000211.9
Start DateStart TimeEnd DateEnd Time
06/16/1999201506/17/19990500
Subject:
SGP/EBBR - EBBR E25 Thermocouple Temperatures Incorrect
DataStreams:sgp15ebbrE25.b1, sgp30ebbrE25.b1, sgp5ebbrE25.b1
Description:
Thermocouple temperature data was incorrect during the period, for unknown 
reasons. 

Affected data are:

5 minute:  tair_top, tair_bot
15 minute: tair_r, tair_l
30 minute: bowen, e, h, tair_top, tair_bot
Measurements:sgp30ebbrE25.b1:
  • latent_heat_flux
  • temp_air_bottom
  • bowen_ratio
  • temp_air_top
  • sensible_heat_flux

sgp5ebbrE25.b1:
  • temp_air_bottom
  • temp_air_top

sgp15ebbrE25.b1:
  • temp_air_right
  • temp_air_left


Back To Table of Contents

DQRID : D000221.3
Start DateStart TimeEnd DateEnd Time
01/08/2000023001/27/20001700
Subject:
SGP/EBBR/E26 - Right Aspirator Not Working
DataStreams:sgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
Description:
The right aspirator fan did not work during the period.

The following values were therefore incorrect:

5 minute:  tair_top, tair_bot, thum_top. thum_bot, hum_top, hum_bot,
           vp_top, vp_bot
15 minute: rr_thum_l, mv_hum_l, tair_l
30 minute: tair_top, tair_bot, thum_top. thum_bot, hum_top, hum_bot,
           vp_top, vp_bot, e, h, bowen
Measurements:sgp30ebbrE26.b1:
  • temp_air_bottom
  • temp_trh_top
  • bowen_ratio
  • rh_top_fraction
  • rh_bottom_fraction
  • latent_heat_flux
  • temp_air_top
  • temp_trh_bottom
  • vapor_pressure_top
  • sensible_heat_flux
  • vapor_pressure_bottom

sgp15ebbrE26.b1:
  • rh_left_mv
  • temp_trh_left_rr
  • temp_air_left

sgp5ebbrE26.b1:
  • temp_trh_top
  • temp_trh_bottom
  • temp_air_top
  • rh_bottom_fraction
  • rh_top_fraction
  • vapor_pressure_top
  • vapor_pressure_bottom
  • temp_air_bottom


Back To Table of Contents

DQRID : D000221.7
Start DateStart TimeEnd DateEnd Time
09/25/1999063510/07/19991620
Subject:
SGP/EBBR/E26 - Anemometer Not Working, Wind Speed Incorrect
DataStreams:sgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
Description:
The anemometer was not working during this period.

The following values were therefore incorrect:

5 minute:  wind_s, res_ws
15 minute: wind_s
30 minute: wind_s, res_ws
Measurements:sgp30ebbrE26.b1:
  • wspd_arith_mean
  • wspd_vec_mean

sgp15ebbrE26.b1:
  • wspd_arith_mean

sgp5ebbrE26.b1:
  • wspd_arith_mean
  • wspd_vec_mean


Back To Table of Contents

DQRID : D000225.1
Start DateStart TimeEnd DateEnd Time
07/27/1999061508/12/19991600
Subject:
SGP/EBBR/26 - Low Battery Condition
DataStreams:sgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
Description:
When battery voltage was less than 10.4 V DC during this period, all
data should be considered to be incorrect.  The cause of the problem
was a broken trace on J-panel #3.
Measurements:sgp30ebbrE26.b1:
  • wspd_vec_mean
  • rh_top_fraction
  • wspd_arith_mean
  • latent_heat_flux
  • vapor_pressure_top
  • vapor_pressure_bottom
  • corr_soil_heat_flow_4
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_1
  • temp_reference
  • corr_soil_heat_flow_5
  • wdir_vec_std
  • temp_air_top
  • surface_soil_heat_flux_5
  • soil_moisture_5
  • surface_soil_heat_flux_3
  • surface_soil_heat_flux_4
  • soil_moisture_1
  • soil_moisture_2
  • soil_moisture_3
  • soil_moisture_4
  • temp_trh_top
  • rh_bottom_fraction
  • home_signal_15
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_1
  • lon(lon)
  • sensible_heat_flux
  • surface_soil_heat_flux_avg
  • net_radiation
  • soil_heat_capacity_5
  • soil_heat_capacity_4
  • soil_heat_capacity_2
  • soil_heat_capacity_3
  • bowen_ratio
  • home_signal_30
  • soil_heat_capacity_1
  • lat(lat)
  • soil_temp_5
  • soil_temp_4
  • soil_heat_flow_3
  • soil_temp_3
  • soil_heat_flow_2
  • soil_temp_2
  • soil_heat_flow_1
  • soil_temp_1
  • soil_heat_flow_5
  • soil_heat_flow_4
  • temp_air_bottom
  • wdir_vec_mean
  • energy_storage_change_1
  • energy_storage_change_2
  • energy_storage_change_3
  • Time offset of tweaks from base_time(time_offset)
  • energy_storage_change_4
  • energy_storage_change_5
  • temp_trh_bottom
  • Dummy altitude for Zeb(alt)
  • Barometric Pressure(atmos_pressure)
  • base time(base_time)

sgp15ebbrE26.b1:
  • wdir_vec_mean_mv
  • soil_heat_flow_4_mv
  • soil_moisture_2_r
  • soil_heat_flow_3_mv
  • soil_temp_1_rr
  • temp_trh_right_rr
  • soil_heat_flow_2_mv
  • battery_voltage
  • lon(lon)
  • soil_temp_3_rr
  • soil_moisture_4_r
  • soil_heat_flow_1_mv
  • soil_moisture_1_r
  • soil_temp_4_rr
  • temp_trh_left_rr
  • lat(lat)
  • temp_air_left
  • Dummy altitude for Zeb(alt)
  • rh_right_mv
  • soil_moisture_3_r
  • home_signal
  • temp_air_right
  • rh_left_mv
  • soil_temp_5_rr
  • soil_heat_flow_5_mv
  • temp_reference_rr
  • Time offset of tweaks from base_time(time_offset)
  • soil_moisture_5_r
  • base time(base_time)
  • soil_temp_2_rr
  • wspd_arith_mean
  • atmos_pressure_mv
  • net_radiation_mv

sgp5ebbrE26.b1:
  • temp_trh_bottom
  • lon(lon)
  • wspd_arith_mean
  • wdir_vec_std
  • rh_top_fraction
  • home_signal
  • Barometric Pressure(atmos_pressure)
  • Time offset of tweaks from base_time(time_offset)
  • rh_bottom_fraction
  • temp_reference
  • wdir_vec_mean
  • temp_trh_top
  • temp_air_top
  • wspd_vec_mean
  • temp_air_bottom
  • vapor_pressure_bottom
  • Dummy altitude for Zeb(alt)
  • vapor_pressure_top
  • net_radiation
  • lat(lat)
  • base time(base_time)


Back To Table of Contents

DQRID : D000301.11
Start DateStart TimeEnd DateEnd Time
07/20/1999030008/04/19991730
Subject:
SGP/EBBR - EBBR E22 Soil Moistures Negative
DataStreams:sgp15ebbrE22.b1, sgp30ebbrE22.b1
Description:
Because of the lack of rain, soil moistures were negative during much 
of the period.  All five soil moisture sensors had negative outputs by 
early on Aug 1.  The negative soil moistures affected sensible and latent
heat fluxes slightly.

The affected data are:

15 minute: r_sm1, r_sm2, r_sm3, r_sm4, r_sm5
30 minute: sm1, sm2, sm3, sm4, sm5, c_shf1, c_shf2, c_shf3, c_shf4,
           c_shf5, cs1, cs2, cs3, cs4, cs5, ces1, ces2, ces3, ces4, ces5,
           g1, g2, g3, g4, g5, ave_shf, e, h
Measurements:sgp30ebbrE22.b1:
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_1
  • corr_soil_heat_flow_4
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_5
  • surface_soil_heat_flux_avg
  • soil_moisture_5
  • energy_storage_change_1
  • soil_moisture_1
  • soil_moisture_2
  • soil_moisture_3
  • soil_moisture_4
  • soil_heat_capacity_5
  • soil_heat_capacity_4
  • sensible_heat_flux
  • soil_heat_capacity_3
  • soil_heat_capacity_2
  • soil_heat_capacity_1
  • energy_storage_change_3
  • energy_storage_change_2
  • energy_storage_change_5
  • energy_storage_change_4
  • latent_heat_flux
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_1
  • surface_soil_heat_flux_4
  • surface_soil_heat_flux_3
  • surface_soil_heat_flux_5

sgp15ebbrE22.b1:
  • soil_moisture_4_r
  • soil_moisture_3_r
  • soil_moisture_1_r
  • soil_moisture_5_r
  • soil_moisture_2_r


Back To Table of Contents

DQRID : D000301.5
Start DateStart TimeEnd DateEnd Time
09/07/1999190009/08/19992200
Subject:
SGP/EBBR - EBBR E25 Net Radiation Incorrect
DataStreams:sgp15ebbrE25.b1, sgp30ebbrE25.b1, sgp5ebbrE25.b1
Description:
The net radiometer top dome was broken and water had entered.  Net 
radiation values are therefore incorrect during the period.

The affected data are:

5 minute:  q
15 minute: mv_q
30 minute: q, h, e
Measurements:sgp30ebbrE25.b1:
  • latent_heat_flux
  • sensible_heat_flux
  • net_radiation

sgp5ebbrE25.b1:
  • net_radiation

sgp15ebbrE25.b1:
  • net_radiation_mv


Back To Table of Contents

DQRID : D000301.9
Start DateStart TimeEnd DateEnd Time
09/25/1999070010/07/19991700
Subject:
SGP/EBBR/E26 - Net Radiation Incorrect
DataStreams:sgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
Description:
The net radiometer top dome was broken and water had entered.  Net 
radiation values are therefore incorrect during the period.

The affected data are:

5 minute:  q
15 minute: mv_q
30 minute: q, h, e
Measurements:sgp30ebbrE26.b1:
  • latent_heat_flux
  • net_radiation
  • sensible_heat_flux

sgp15ebbrE26.b1:
  • net_radiation_mv

sgp5ebbrE26.b1:
  • net_radiation


Back To Table of Contents

DQRID : D000302.2
Start DateStart TimeEnd DateEnd Time
08/15/1999080010/30/19990300
Subject:
SGP/EBBR - EBBR E22 Soil Moistures Negative
DataStreams:sgp15ebbrE22.b1, sgp30ebbrE22.b1
Description:
Because of the lack of rain, all soil moistures were negative during much 
of the period.  The negative soil moistures caused soil heat storage and
thus average soil heat flux to be smaller than they should have been.  The
sensible and latent heat fluxes were therefore reduced slightly 
(approximately 0-5%).

The affected data are:

15 minute: r_sm1, r_sm2, r_sm3, r_sm4, r_sm5
30 minute: sm1, sm2, sm3, sm4, sm5, c_shf1, c_shf2, c_shf3, c_shf4,
           c_shf5, cs1, cs2, cs3, cs4, cs5, ces1, ces2, ces3, ces4, ces5,
           g1, g2, g3, g4, g5, ave_shf, e, h
Measurements:sgp30ebbrE22.b1:
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_1
  • corr_soil_heat_flow_4
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_5
  • surface_soil_heat_flux_avg
  • soil_moisture_5
  • energy_storage_change_1
  • soil_moisture_1
  • soil_moisture_2
  • soil_moisture_3
  • soil_moisture_4
  • soil_heat_capacity_5
  • soil_heat_capacity_4
  • sensible_heat_flux
  • soil_heat_capacity_3
  • soil_heat_capacity_2
  • soil_heat_capacity_1
  • energy_storage_change_3
  • energy_storage_change_2
  • energy_storage_change_5
  • energy_storage_change_4
  • latent_heat_flux
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_1
  • surface_soil_heat_flux_4
  • surface_soil_heat_flux_3
  • surface_soil_heat_flux_5

sgp15ebbrE22.b1:
  • soil_moisture_4_r
  • soil_moisture_3_r
  • soil_moisture_1_r
  • soil_moisture_5_r
  • soil_moisture_2_r


Back To Table of Contents

DQRID : D000307.10
Start DateStart TimeEnd DateEnd Time
08/04/1999180008/04/19991800
Subject:
SGP/EBBR - EBBR E25 Soil Heat Flow #1 Incorrect
DataStreams:sgp15ebbrE25.b1, sgp30ebbrE25.b1
Description:
Soil heat flux #1 was large negative or offscale numerous times.
Measurements:sgp30ebbrE25.b1:
  • latent_heat_flux
  • soil_heat_flow_3
  • surface_soil_heat_flux_1
  • corr_soil_heat_flow_1
  • surface_soil_heat_flux_avg
  • sensible_heat_flux

sgp15ebbrE25.b1:
  • soil_heat_flow_1_mv


Back To Table of Contents

DQRID : D000307.11
Start DateStart TimeEnd DateEnd Time
08/05/1999010008/05/19990200
Subject:
SGP/EBBR - EBBR E25 Soil Heat Flow #1 Incorrect
DataStreams:sgp15ebbrE25.b1, sgp30ebbrE25.b1
Description:
Soil heat flux #1 was large negative or offscale numerous times.
Measurements:sgp30ebbrE25.b1:
  • latent_heat_flux
  • soil_heat_flow_3
  • surface_soil_heat_flux_1
  • corr_soil_heat_flow_1
  • surface_soil_heat_flux_avg
  • sensible_heat_flux

sgp15ebbrE25.b1:
  • soil_heat_flow_1_mv


Back To Table of Contents

DQRID : D000307.12
Start DateStart TimeEnd DateEnd Time
08/06/1999183008/06/19991830
Subject:
SGP/EBBR - EBBR E25 Soil Heat Flow #1 Incorrect
DataStreams:sgp15ebbrE25.b1, sgp30ebbrE25.b1
Description:
Soil heat flux #1 was large negative or offscale numerous times.
Measurements:sgp30ebbrE25.b1:
  • latent_heat_flux
  • soil_heat_flow_3
  • surface_soil_heat_flux_1
  • corr_soil_heat_flow_1
  • surface_soil_heat_flux_avg
  • sensible_heat_flux

sgp15ebbrE25.b1:
  • soil_heat_flow_1_mv


Back To Table of Contents

DQRID : D000307.13
Start DateStart TimeEnd DateEnd Time
08/07/1999013008/07/19990130
Subject:
SGP/EBBR - EBBR E25 Soil Heat Flow #1 Incorrect
DataStreams:sgp15ebbrE25.b1, sgp30ebbrE25.b1
Description:
Soil heat flux #1 was large negative or offscale numerous times.
Measurements:sgp30ebbrE25.b1:
  • latent_heat_flux
  • soil_heat_flow_3
  • surface_soil_heat_flux_1
  • corr_soil_heat_flow_1
  • surface_soil_heat_flux_avg
  • sensible_heat_flux

sgp15ebbrE25.b1:
  • soil_heat_flow_1_mv


Back To Table of Contents

DQRID : D000307.14
Start DateStart TimeEnd DateEnd Time
08/17/1999013008/17/19990130
Subject:
SGP/EBBR - EBBR E25 Soil Heat Flow #1 Incorrect
DataStreams:sgp15ebbrE25.b1, sgp30ebbrE25.b1
Description:
Soil heat flux #1 was large negative or offscale numerous times.
Measurements:sgp30ebbrE25.b1:
  • latent_heat_flux
  • soil_heat_flow_3
  • surface_soil_heat_flux_1
  • corr_soil_heat_flow_1
  • surface_soil_heat_flux_avg
  • sensible_heat_flux

sgp15ebbrE25.b1:
  • soil_heat_flow_1_mv


Back To Table of Contents

DQRID : D000307.15
Start DateStart TimeEnd DateEnd Time
08/18/1999020008/18/19990400
Subject:
SGP/EBBR - EBBR E25 Soil Heat Flow #1 Incorrect
DataStreams:sgp15ebbrE25.b1, sgp30ebbrE25.b1
Description:
Soil heat flux #1 was large negative or offscale numerous times.
Measurements:sgp30ebbrE25.b1:
  • latent_heat_flux
  • soil_heat_flow_3
  • surface_soil_heat_flux_1
  • corr_soil_heat_flow_1
  • surface_soil_heat_flux_avg
  • sensible_heat_flux

sgp15ebbrE25.b1:
  • soil_heat_flow_1_mv


Back To Table of Contents

DQRID : D000307.16
Start DateStart TimeEnd DateEnd Time
08/18/1999093008/18/19991030
Subject:
SGP/EBBR - EBBR E25 Soil Heat Flow #1 Incorrect
DataStreams:sgp15ebbrE25.b1, sgp30ebbrE25.b1
Description:
Soil heat flux #1 was large negative or offscale numerous times.
Measurements:sgp30ebbrE25.b1:
  • latent_heat_flux
  • soil_heat_flow_3
  • surface_soil_heat_flux_1
  • corr_soil_heat_flow_1
  • surface_soil_heat_flux_avg
  • sensible_heat_flux

sgp15ebbrE25.b1:
  • soil_heat_flow_1_mv


Back To Table of Contents

DQRID : D000307.17
Start DateStart TimeEnd DateEnd Time
10/15/1999200010/15/19992330
Subject:
SGP/EBBR - EBBR E25 Soil Heat Flow #1 Incorrect
DataStreams:sgp15ebbrE25.b1, sgp30ebbrE25.b1
Description:
Soil heat flux #1 was large negative or offscale numerous times.
Measurements:sgp30ebbrE25.b1:
  • latent_heat_flux
  • soil_heat_flow_3
  • surface_soil_heat_flux_1
  • corr_soil_heat_flow_1
  • surface_soil_heat_flux_avg
  • sensible_heat_flux

sgp15ebbrE25.b1:
  • soil_heat_flow_1_mv


Back To Table of Contents

DQRID : D000307.18
Start DateStart TimeEnd DateEnd Time
10/26/1999000010/26/19990030
Subject:
SGP/EBBR - EBBR E25 Soil Heat Flow #1 Incorrect
DataStreams:sgp15ebbrE25.b1, sgp30ebbrE25.b1
Description:
Soil heat flux #1 was large negative or offscale numerous times.
Measurements:sgp30ebbrE25.b1:
  • latent_heat_flux
  • soil_heat_flow_3
  • surface_soil_heat_flux_1
  • corr_soil_heat_flow_1
  • surface_soil_heat_flux_avg
  • sensible_heat_flux

sgp15ebbrE25.b1:
  • soil_heat_flow_1_mv


Back To Table of Contents

DQRID : D000307.2
Start DateStart TimeEnd DateEnd Time
07/26/1999010007/26/19990530
Subject:
SGP/EBBR - EBBR E25 Soil Heat Flow #1 Incorrect
DataStreams:sgp15ebbrE25.b1, sgp30ebbrE25.b1
Description:
Soil heat flux #1 was large negative or offscale numerous times.
Measurements:sgp30ebbrE25.b1:
  • latent_heat_flux
  • soil_heat_flow_3
  • surface_soil_heat_flux_1
  • corr_soil_heat_flow_1
  • surface_soil_heat_flux_avg
  • sensible_heat_flux

sgp15ebbrE25.b1:
  • soil_heat_flow_1_mv


Back To Table of Contents

DQRID : D000307.5
Start DateStart TimeEnd DateEnd Time
08/03/1999010008/03/19990430
Subject:
SGP/EBBR - EBBR E25 Soil Heat Flow #1 Incorrect
DataStreams:sgp15ebbrE25.b1, sgp30ebbrE25.b1
Description:
Soil heat flux #1 was large negative or offscale numerous times.
Measurements:sgp30ebbrE25.b1:
  • latent_heat_flux
  • soil_heat_flow_3
  • surface_soil_heat_flux_1
  • corr_soil_heat_flow_1
  • surface_soil_heat_flux_avg
  • sensible_heat_flux

sgp15ebbrE25.b1:
  • soil_heat_flow_1_mv


Back To Table of Contents

DQRID : D000307.6
Start DateStart TimeEnd DateEnd Time
08/02/1999173008/16/19991800
Subject:
SGP/EBBR - EBBR E25 Soil Heat Flow #1 Incorrect
DataStreams:sgp15ebbrE25.b1, sgp30ebbrE25.b1
Description:
Soil heat flux #1 was large negative or offscale numerous times.
Measurements:sgp30ebbrE25.b1:
  • latent_heat_flux
  • soil_heat_flow_3
  • surface_soil_heat_flux_1
  • corr_soil_heat_flow_1
  • surface_soil_heat_flux_avg
  • sensible_heat_flux

sgp15ebbrE25.b1:
  • soil_heat_flow_1_mv


Back To Table of Contents

DQRID : D000307.7
Start DateStart TimeEnd DateEnd Time
08/02/1999010008/02/19990230
Subject:
SGP/EBBR - EBBR E25 Soil Heat Flow #1 Incorrect
DataStreams:sgp15ebbrE25.b1, sgp30ebbrE25.b1
Description:
Soil heat flux #1 was large negative or offscale numerous times.
Measurements:sgp30ebbrE25.b1:
  • latent_heat_flux
  • soil_heat_flow_3
  • surface_soil_heat_flux_1
  • corr_soil_heat_flow_1
  • surface_soil_heat_flux_avg
  • sensible_heat_flux

sgp15ebbrE25.b1:
  • soil_heat_flow_1_mv


Back To Table of Contents

DQRID : D000307.8
Start DateStart TimeEnd DateEnd Time
08/03/1999180008/03/19991800
Subject:
SGP/EBBR - EBBR E25 Soil Heat Flow #1 Incorrect
DataStreams:sgp15ebbrE25.b1, sgp30ebbrE25.b1
Description:
Soil heat flux #1 was large negative or offscale numerous times.
Measurements:sgp30ebbrE25.b1:
  • latent_heat_flux
  • soil_heat_flow_3
  • surface_soil_heat_flux_1
  • corr_soil_heat_flow_1
  • surface_soil_heat_flux_avg
  • sensible_heat_flux

sgp15ebbrE25.b1:
  • soil_heat_flow_1_mv


Back To Table of Contents

DQRID : D000307.9
Start DateStart TimeEnd DateEnd Time
08/04/1999010008/04/19990200
Subject:
SGP/EBBR - EBBR E25 Soil Heat Flow #1 Incorrect
DataStreams:sgp15ebbrE25.b1, sgp30ebbrE25.b1
Description:
Soil heat flux #1 was large negative or offscale numerous times.
Measurements:sgp30ebbrE25.b1:
  • latent_heat_flux
  • soil_heat_flow_3
  • surface_soil_heat_flux_1
  • corr_soil_heat_flow_1
  • surface_soil_heat_flux_avg
  • sensible_heat_flux

sgp15ebbrE25.b1:
  • soil_heat_flow_1_mv


Back To Table of Contents

DQRID : D000622.1
Start DateStart TimeEnd DateEnd Time
07/17/1996000004/01/19991410
Subject:
SGP/EBBR/E26 - Reprocess Soil Moisture Off-Scale
DataStreams:sgp15ebbrE26.b1, sgp30ebbrE26.b1
Description:
During numerous periods within the days listed above, individual soil
moisture probes indicate small positive or else negative values when
soil moisture is high (greater than 35%).  This situation has occured
since the present EBBR unit was installed on 17 July 1996.  The cause
of the problem is inadequate range in the calibration curve equation.
Cement soil is somewhat unique amongst the EBBR sites, as the soil is
very sandy and porous; it can hold a larger amount of water per volume
than the other soils.  This high a soil moisture cannot be obtained with
the calibration soil used by REBS.  Therefore, the soil moisture equations
need to be manipulated to allow larger soil moistures to be calculated.
Much of the data from January 1998 is corrupted by this problem,
making changes in the equations prudent.

The soil moisture data must be inspected by the data user to see when
soil moisture values for one or more probes is inconsistent with the
others.

Recalculation of ave_shf, e, and h must be made using only the soil
moisture sets with correct soil moisture values.
Affected data values are (# for probe number):

15 minute: rr_sm#

30 minute: sm#, c_shf#, cs#, ces#, g#, ave_shf, e, h

Sensible, latent, and soil heat fluxes can be recalculated using the soil
probe sets that provide correct data.  For example, if soil moisture 2 is
incorrect,

ave_shf = (g1 + g3 + g4 + g5)/4

e = -(q + ave_shf)/(1 +bowen)

h = -(e + ave_shf +q),


If soil moisture 2 and 4 are incorrect,

ave_shf = (g1 + g3 + g5)/3

e = -(q + ave_shf)/(1 +bowen)

h = -(e + ave_shf +q),


If soil moisture 2, 4, and 5 are incorrect,

ave_shf = (g1 + g3)/2

e = -(q + ave_shf)/(1 +bowen)

h = -(e + ave_shf +q),

etc.

On 5 May 1998 at 1815 GMT a calibration coefficient was changed in the CR10
program as a result of a BCR by the mentor.  This coefficient has helped
reduce the least severe problems but has not eliminated problems from
large negative soil moistures measured even once during the integration
period.  However, now the incorrect average soil heat flow, latent heat
flux, and sensible heat flux are so large, negative or positive, that they
cannot be mistaken as being correct. 

The EBBR unit was replaced with a recalibrated system on 1 April 1999.
The previous unit experienced soil moisture problems the entire time
(almost 3 years) that the system was installed because of the inadequacy
of the soil moisture sensor calibrations.
Measurements:sgp30ebbrE26.b1:
  • surface_soil_heat_flux_avg
  • energy_storage_change_1
  • energy_storage_change_2
  • energy_storage_change_3
  • energy_storage_change_4
  • energy_storage_change_5
  • surface_soil_heat_flux_5
  • soil_moisture_5
  • surface_soil_heat_flux_3
  • surface_soil_heat_flux_4
  • soil_moisture_1
  • soil_heat_capacity_5
  • soil_moisture_2
  • soil_heat_capacity_4
  • soil_moisture_3
  • soil_moisture_4
  • soil_heat_capacity_2
  • soil_heat_capacity_3
  • soil_heat_capacity_1
  • latent_heat_flux
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_1
  • sensible_heat_flux
  • corr_soil_heat_flow_4
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_1
  • corr_soil_heat_flow_5

sgp15ebbrE26.b1:
  • soil_moisture_1_r
  • soil_moisture_5_r
  • soil_moisture_3_r
  • soil_moisture_2_r
  • soil_moisture_4_r


Back To Table of Contents

DQRID : D000623.1
Start DateStart TimeEnd DateEnd Time
04/28/2000204505/04/20001500
Subject:
SGP/EBBR/E26 - EBBR E26 Left Aspirator Not Working
DataStreams:sgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
Description:
The data is suspect because of inadequate aspiration for the sensors
in the left aspirated radiation shield.
Measurements:sgp30ebbrE26.b1:
  • temp_air_bottom
  • temp_trh_top
  • bowen_ratio
  • rh_top_fraction
  • rh_bottom_fraction
  • latent_heat_flux
  • temp_air_top
  • temp_trh_bottom
  • vapor_pressure_top
  • sensible_heat_flux
  • vapor_pressure_bottom

sgp15ebbrE26.b1:
  • rh_left_mv
  • temp_trh_left_rr
  • temp_air_left

sgp5ebbrE26.b1:
  • temp_trh_top
  • temp_trh_bottom
  • temp_air_top
  • rh_bottom_fraction
  • rh_top_fraction
  • vapor_pressure_top
  • vapor_pressure_bottom
  • temp_air_bottom


Back To Table of Contents

DQRID : D000623.10
Start DateStart TimeEnd DateEnd Time
02/22/2000133002/22/20001500
Subject:
SGP/EBBR/E26 - EBBR E26 All Data Incorrect
DataStreams:sgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
Description:
All data was incorrect for an unknown reason.
Measurements:sgp30ebbrE26.b1:
  • wspd_vec_mean
  • rh_top_fraction
  • wspd_arith_mean
  • latent_heat_flux
  • vapor_pressure_top
  • vapor_pressure_bottom
  • corr_soil_heat_flow_4
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_1
  • temp_reference
  • corr_soil_heat_flow_5
  • wdir_vec_std
  • temp_air_top
  • surface_soil_heat_flux_5
  • soil_moisture_5
  • surface_soil_heat_flux_3
  • surface_soil_heat_flux_4
  • soil_moisture_1
  • soil_moisture_2
  • soil_moisture_3
  • soil_moisture_4
  • temp_trh_top
  • rh_bottom_fraction
  • home_signal_15
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_1
  • sensible_heat_flux
  • surface_soil_heat_flux_avg
  • net_radiation
  • soil_heat_capacity_5
  • soil_heat_capacity_4
  • soil_heat_capacity_2
  • soil_heat_capacity_3
  • bowen_ratio
  • home_signal_30
  • soil_heat_capacity_1
  • soil_temp_5
  • soil_temp_4
  • soil_heat_flow_3
  • soil_temp_3
  • soil_heat_flow_2
  • soil_temp_2
  • soil_heat_flow_1
  • soil_temp_1
  • soil_heat_flow_5
  • soil_heat_flow_4
  • temp_air_bottom
  • wdir_vec_mean
  • energy_storage_change_1
  • energy_storage_change_2
  • energy_storage_change_3
  • energy_storage_change_4
  • energy_storage_change_5
  • temp_trh_bottom
  • Barometric Pressure(atmos_pressure)

sgp15ebbrE26.b1:
  • wdir_vec_mean_mv
  • soil_heat_flow_4_mv
  • soil_moisture_2_r
  • soil_heat_flow_3_mv
  • soil_temp_1_rr
  • temp_trh_right_rr
  • soil_heat_flow_2_mv
  • battery_voltage
  • soil_temp_3_rr
  • soil_moisture_4_r
  • soil_heat_flow_1_mv
  • soil_moisture_1_r
  • soil_temp_4_rr
  • temp_trh_left_rr
  • temp_air_left
  • rh_right_mv
  • soil_moisture_3_r
  • home_signal
  • temp_air_right
  • rh_left_mv
  • soil_temp_5_rr
  • soil_heat_flow_5_mv
  • temp_reference_rr
  • soil_moisture_5_r
  • soil_temp_2_rr
  • wspd_arith_mean
  • atmos_pressure_mv
  • net_radiation_mv

sgp5ebbrE26.b1:
  • temp_trh_bottom
  • wspd_arith_mean
  • wdir_vec_std
  • rh_top_fraction
  • home_signal
  • Barometric Pressure(atmos_pressure)
  • rh_bottom_fraction
  • temp_reference
  • wdir_vec_mean
  • temp_trh_top
  • temp_air_top
  • wspd_vec_mean
  • temp_air_bottom
  • vapor_pressure_bottom
  • vapor_pressure_top
  • net_radiation


Back To Table of Contents

DQRID : D000623.11
Start DateStart TimeEnd DateEnd Time
02/22/2000230002/23/20000030
Subject:
SGP/EBBR/E26 - All Data Incorrect
DataStreams:sgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
Description:
All data wqas incorrect for an unknown reason.
Measurements:sgp30ebbrE26.b1:
  • wspd_vec_mean
  • rh_top_fraction
  • wspd_arith_mean
  • latent_heat_flux
  • vapor_pressure_top
  • vapor_pressure_bottom
  • corr_soil_heat_flow_4
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_1
  • temp_reference
  • corr_soil_heat_flow_5
  • wdir_vec_std
  • temp_air_top
  • surface_soil_heat_flux_5
  • soil_moisture_5
  • surface_soil_heat_flux_3
  • surface_soil_heat_flux_4
  • soil_moisture_1
  • soil_moisture_2
  • soil_moisture_3
  • soil_moisture_4
  • temp_trh_top
  • rh_bottom_fraction
  • home_signal_15
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_1
  • sensible_heat_flux
  • surface_soil_heat_flux_avg
  • net_radiation
  • soil_heat_capacity_5
  • soil_heat_capacity_4
  • soil_heat_capacity_2
  • soil_heat_capacity_3
  • bowen_ratio
  • home_signal_30
  • soil_heat_capacity_1
  • soil_temp_5
  • soil_temp_4
  • soil_heat_flow_3
  • soil_temp_3
  • soil_heat_flow_2
  • soil_temp_2
  • soil_heat_flow_1
  • soil_temp_1
  • soil_heat_flow_5
  • soil_heat_flow_4
  • temp_air_bottom
  • wdir_vec_mean
  • energy_storage_change_1
  • energy_storage_change_2
  • energy_storage_change_3
  • energy_storage_change_4
  • energy_storage_change_5
  • temp_trh_bottom
  • Barometric Pressure(atmos_pressure)

sgp15ebbrE26.b1:
  • wdir_vec_mean_mv
  • soil_heat_flow_4_mv
  • soil_moisture_2_r
  • soil_heat_flow_3_mv
  • soil_temp_1_rr
  • temp_trh_right_rr
  • soil_heat_flow_2_mv
  • battery_voltage
  • soil_temp_3_rr
  • soil_moisture_4_r
  • soil_heat_flow_1_mv
  • soil_moisture_1_r
  • soil_temp_4_rr
  • temp_trh_left_rr
  • temp_air_left
  • rh_right_mv
  • soil_moisture_3_r
  • home_signal
  • temp_air_right
  • rh_left_mv
  • soil_temp_5_rr
  • soil_heat_flow_5_mv
  • temp_reference_rr
  • soil_moisture_5_r
  • soil_temp_2_rr
  • wspd_arith_mean
  • atmos_pressure_mv
  • net_radiation_mv

sgp5ebbrE26.b1:
  • temp_trh_bottom
  • wspd_arith_mean
  • wdir_vec_std
  • rh_top_fraction
  • home_signal
  • Barometric Pressure(atmos_pressure)
  • rh_bottom_fraction
  • temp_reference
  • wdir_vec_mean
  • temp_trh_top
  • temp_air_top
  • wspd_vec_mean
  • temp_air_bottom
  • vapor_pressure_bottom
  • vapor_pressure_top
  • net_radiation


Back To Table of Contents

DQRID : D000623.2
Start DateStart TimeEnd DateEnd Time
04/06/2000163004/06/20001700
Subject:
SGP/EBBR/E26 - All Data Incorrect
DataStreams:sgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
Description:
Data was incorrect because of Preventative Maintenance activities.
Measurements:sgp30ebbrE26.b1:
  • wspd_vec_mean
  • rh_top_fraction
  • wspd_arith_mean
  • latent_heat_flux
  • vapor_pressure_top
  • vapor_pressure_bottom
  • corr_soil_heat_flow_4
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_1
  • temp_reference
  • corr_soil_heat_flow_5
  • wdir_vec_std
  • temp_air_top
  • surface_soil_heat_flux_5
  • soil_moisture_5
  • surface_soil_heat_flux_3
  • surface_soil_heat_flux_4
  • soil_moisture_1
  • soil_moisture_2
  • soil_moisture_3
  • soil_moisture_4
  • temp_trh_top
  • rh_bottom_fraction
  • home_signal_15
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_1
  • sensible_heat_flux
  • surface_soil_heat_flux_avg
  • net_radiation
  • soil_heat_capacity_5
  • soil_heat_capacity_4
  • soil_heat_capacity_2
  • soil_heat_capacity_3
  • bowen_ratio
  • home_signal_30
  • soil_heat_capacity_1
  • soil_temp_5
  • soil_temp_4
  • soil_heat_flow_3
  • soil_temp_3
  • soil_heat_flow_2
  • soil_temp_2
  • soil_heat_flow_1
  • soil_temp_1
  • soil_heat_flow_5
  • soil_heat_flow_4
  • temp_air_bottom
  • wdir_vec_mean
  • energy_storage_change_1
  • energy_storage_change_2
  • energy_storage_change_3
  • energy_storage_change_4
  • energy_storage_change_5
  • temp_trh_bottom
  • Barometric Pressure(atmos_pressure)

sgp15ebbrE26.b1:
  • wdir_vec_mean_mv
  • soil_heat_flow_4_mv
  • soil_moisture_2_r
  • soil_heat_flow_3_mv
  • soil_temp_1_rr
  • temp_trh_right_rr
  • soil_heat_flow_2_mv
  • battery_voltage
  • soil_temp_3_rr
  • soil_moisture_4_r
  • soil_heat_flow_1_mv
  • soil_moisture_1_r
  • soil_temp_4_rr
  • temp_trh_left_rr
  • temp_air_left
  • rh_right_mv
  • soil_moisture_3_r
  • home_signal
  • temp_air_right
  • rh_left_mv
  • soil_temp_5_rr
  • soil_heat_flow_5_mv
  • temp_reference_rr
  • soil_moisture_5_r
  • soil_temp_2_rr
  • wspd_arith_mean
  • atmos_pressure_mv
  • net_radiation_mv

sgp5ebbrE26.b1:
  • temp_trh_bottom
  • wspd_arith_mean
  • wdir_vec_std
  • rh_top_fraction
  • home_signal
  • Barometric Pressure(atmos_pressure)
  • rh_bottom_fraction
  • temp_reference
  • wdir_vec_mean
  • temp_trh_top
  • temp_air_top
  • wspd_vec_mean
  • temp_air_bottom
  • vapor_pressure_bottom
  • vapor_pressure_top
  • net_radiation


Back To Table of Contents

DQRID : D000623.3
Start DateStart TimeEnd DateEnd Time
04/13/2000121504/13/20001415
Subject:
SGP/EBBR/E26 - Low Battery Voltage Causes Incorrect Data
DataStreams:sgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
Description:
Battery voltage below about 10.5 volts DC caused a number of the
EBBR sensors to not measure correctly.
Measurements:sgp30ebbrE26.b1:
  • surface_soil_heat_flux_avg
  • energy_storage_change_1
  • energy_storage_change_2
  • energy_storage_change_3
  • energy_storage_change_4
  • energy_storage_change_5
  • surface_soil_heat_flux_5
  • surface_soil_heat_flux_3
  • surface_soil_heat_flux_4
  • soil_heat_capacity_5
  • soil_heat_capacity_4
  • soil_heat_capacity_2
  • soil_heat_capacity_3
  • soil_heat_capacity_1
  • home_signal_30
  • home_signal_15
  • latent_heat_flux
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_1
  • soil_temp_5
  • soil_temp_4
  • soil_heat_flow_3
  • soil_temp_3
  • soil_heat_flow_2
  • soil_temp_2
  • soil_heat_flow_1
  • soil_temp_1
  • soil_heat_flow_5
  • soil_heat_flow_4
  • sensible_heat_flux
  • corr_soil_heat_flow_4
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_1
  • corr_soil_heat_flow_5

sgp15ebbrE26.b1:
  • soil_heat_flow_4_mv
  • soil_temp_4_rr
  • soil_temp_5_rr
  • soil_heat_flow_5_mv
  • soil_heat_flow_2_mv
  • soil_temp_3_rr
  • home_signal
  • soil_temp_2_rr
  • soil_heat_flow_3_mv
  • soil_temp_1_rr
  • soil_heat_flow_1_mv

sgp5ebbrE26.b1:
  • home_signal


Back To Table of Contents

DQRID : D000623.5
Start DateStart TimeEnd DateEnd Time
04/13/2000174504/13/20001800
Subject:
SGP/EBBR/E26 - Low Battery Voltage Causes Incorrect Data
DataStreams:sgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
Description:
Battery voltage less than 10.5 volts DC causes some
sensors to measure incorrectly.
Measurements:sgp30ebbrE26.b1:
  • surface_soil_heat_flux_avg
  • energy_storage_change_1
  • energy_storage_change_2
  • energy_storage_change_3
  • energy_storage_change_4
  • energy_storage_change_5
  • surface_soil_heat_flux_5
  • surface_soil_heat_flux_3
  • surface_soil_heat_flux_4
  • soil_heat_capacity_5
  • soil_heat_capacity_4
  • soil_heat_capacity_2
  • soil_heat_capacity_3
  • soil_heat_capacity_1
  • home_signal_30
  • home_signal_15
  • latent_heat_flux
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_1
  • soil_temp_5
  • soil_temp_4
  • soil_heat_flow_3
  • soil_temp_3
  • soil_heat_flow_2
  • soil_temp_2
  • soil_heat_flow_1
  • soil_temp_1
  • soil_heat_flow_5
  • soil_heat_flow_4
  • sensible_heat_flux
  • corr_soil_heat_flow_4
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_1
  • corr_soil_heat_flow_5

sgp15ebbrE26.b1:
  • soil_heat_flow_4_mv
  • soil_temp_4_rr
  • soil_temp_5_rr
  • soil_heat_flow_5_mv
  • soil_heat_flow_2_mv
  • soil_temp_3_rr
  • home_signal
  • soil_temp_2_rr
  • soil_heat_flow_3_mv
  • soil_temp_1_rr
  • soil_heat_flow_1_mv

sgp5ebbrE26.b1:
  • home_signal


Back To Table of Contents

DQRID : D000623.6
Start DateStart TimeEnd DateEnd Time
04/14/2000061504/14/20001530
Subject:
SGP/EBBR/E26 - Low Battery Voltage Causes Incorrect Data
DataStreams:sgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
Description:
Battery voltage less than 10.5 volts DC causes
some sensors to measure incorrectly.
Measurements:sgp30ebbrE26.b1:
  • surface_soil_heat_flux_avg
  • energy_storage_change_1
  • energy_storage_change_2
  • energy_storage_change_3
  • energy_storage_change_4
  • energy_storage_change_5
  • surface_soil_heat_flux_5
  • surface_soil_heat_flux_3
  • surface_soil_heat_flux_4
  • soil_heat_capacity_5
  • soil_heat_capacity_4
  • soil_heat_capacity_2
  • soil_heat_capacity_3
  • soil_heat_capacity_1
  • home_signal_30
  • home_signal_15
  • latent_heat_flux
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_1
  • soil_temp_5
  • soil_temp_4
  • soil_heat_flow_3
  • soil_temp_3
  • soil_heat_flow_2
  • soil_temp_2
  • soil_heat_flow_1
  • soil_temp_1
  • soil_heat_flow_5
  • soil_heat_flow_4
  • sensible_heat_flux
  • corr_soil_heat_flow_4
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_1
  • corr_soil_heat_flow_5

sgp15ebbrE26.b1:
  • soil_heat_flow_4_mv
  • soil_temp_4_rr
  • soil_temp_5_rr
  • soil_heat_flow_5_mv
  • soil_heat_flow_2_mv
  • soil_temp_3_rr
  • home_signal
  • soil_temp_2_rr
  • soil_heat_flow_3_mv
  • soil_temp_1_rr
  • soil_heat_flow_1_mv

sgp5ebbrE26.b1:
  • home_signal


Back To Table of Contents

DQRID : D000623.7
Start DateStart TimeEnd DateEnd Time
04/16/2000084504/16/20001500
Subject:
SGP/EBBR/E26 - Low Battery Voltage Causes Incorrect Data
DataStreams:sgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
Description:
Battery voltage less than 10.5 volts DC causes
some sensors to make incorrect measurements.
Measurements:sgp30ebbrE26.b1:
  • surface_soil_heat_flux_avg
  • energy_storage_change_1
  • energy_storage_change_2
  • energy_storage_change_3
  • energy_storage_change_4
  • energy_storage_change_5
  • surface_soil_heat_flux_5
  • surface_soil_heat_flux_3
  • surface_soil_heat_flux_4
  • soil_heat_capacity_5
  • soil_heat_capacity_4
  • soil_heat_capacity_2
  • soil_heat_capacity_3
  • soil_heat_capacity_1
  • home_signal_30
  • home_signal_15
  • latent_heat_flux
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_1
  • soil_temp_5
  • soil_temp_4
  • soil_heat_flow_3
  • soil_temp_3
  • soil_heat_flow_2
  • soil_temp_2
  • soil_heat_flow_1
  • soil_temp_1
  • soil_heat_flow_5
  • soil_heat_flow_4
  • sensible_heat_flux
  • corr_soil_heat_flow_4
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_1
  • corr_soil_heat_flow_5

sgp15ebbrE26.b1:
  • soil_heat_flow_4_mv
  • soil_temp_4_rr
  • soil_temp_5_rr
  • soil_heat_flow_5_mv
  • soil_heat_flow_2_mv
  • soil_temp_3_rr
  • home_signal
  • soil_temp_2_rr
  • soil_heat_flow_3_mv
  • soil_temp_1_rr
  • soil_heat_flow_1_mv

sgp5ebbrE26.b1:
  • home_signal


Back To Table of Contents

DQRID : D000623.8
Start DateStart TimeEnd DateEnd Time
03/24/2000000003/24/20000030
Subject:
SGP/EBBR/E26 - All Data Incorrect
DataStreams:sgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
Description:
All data was incorrect for an unknown reason.
Measurements:sgp30ebbrE26.b1:
  • wspd_vec_mean
  • rh_top_fraction
  • wspd_arith_mean
  • latent_heat_flux
  • vapor_pressure_top
  • vapor_pressure_bottom
  • corr_soil_heat_flow_4
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_1
  • temp_reference
  • corr_soil_heat_flow_5
  • wdir_vec_std
  • temp_air_top
  • surface_soil_heat_flux_5
  • soil_moisture_5
  • surface_soil_heat_flux_3
  • surface_soil_heat_flux_4
  • soil_moisture_1
  • soil_moisture_2
  • soil_moisture_3
  • soil_moisture_4
  • temp_trh_top
  • rh_bottom_fraction
  • home_signal_15
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_1
  • sensible_heat_flux
  • surface_soil_heat_flux_avg
  • net_radiation
  • soil_heat_capacity_5
  • soil_heat_capacity_4
  • soil_heat_capacity_2
  • soil_heat_capacity_3
  • bowen_ratio
  • home_signal_30
  • soil_heat_capacity_1
  • soil_temp_5
  • soil_temp_4
  • soil_heat_flow_3
  • soil_temp_3
  • soil_heat_flow_2
  • soil_temp_2
  • soil_heat_flow_1
  • soil_temp_1
  • soil_heat_flow_5
  • soil_heat_flow_4
  • temp_air_bottom
  • wdir_vec_mean
  • energy_storage_change_1
  • energy_storage_change_2
  • energy_storage_change_3
  • energy_storage_change_4
  • energy_storage_change_5
  • temp_trh_bottom
  • Barometric Pressure(atmos_pressure)

sgp15ebbrE26.b1:
  • wdir_vec_mean_mv
  • soil_heat_flow_4_mv
  • soil_moisture_2_r
  • soil_heat_flow_3_mv
  • soil_temp_1_rr
  • temp_trh_right_rr
  • soil_heat_flow_2_mv
  • battery_voltage
  • soil_temp_3_rr
  • soil_moisture_4_r
  • soil_heat_flow_1_mv
  • soil_moisture_1_r
  • soil_temp_4_rr
  • temp_trh_left_rr
  • temp_air_left
  • rh_right_mv
  • soil_moisture_3_r
  • home_signal
  • temp_air_right
  • rh_left_mv
  • soil_temp_5_rr
  • soil_heat_flow_5_mv
  • temp_reference_rr
  • soil_moisture_5_r
  • soil_temp_2_rr
  • wspd_arith_mean
  • atmos_pressure_mv
  • net_radiation_mv

sgp5ebbrE26.b1:
  • temp_trh_bottom
  • wspd_arith_mean
  • wdir_vec_std
  • rh_top_fraction
  • home_signal
  • Barometric Pressure(atmos_pressure)
  • rh_bottom_fraction
  • temp_reference
  • wdir_vec_mean
  • temp_trh_top
  • temp_air_top
  • wspd_vec_mean
  • temp_air_bottom
  • vapor_pressure_bottom
  • vapor_pressure_top
  • net_radiation


Back To Table of Contents

DQRID : D000623.9
Start DateStart TimeEnd DateEnd Time
03/15/2000103003/15/20001430
Subject:
SGP/EBBR/E26 - All Data Incorrect
DataStreams:sgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
Description:
All data was incorrect for an unknown reason.
Measurements:sgp30ebbrE26.b1:
  • wspd_vec_mean
  • rh_top_fraction
  • wspd_arith_mean
  • latent_heat_flux
  • vapor_pressure_top
  • vapor_pressure_bottom
  • corr_soil_heat_flow_4
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_1
  • temp_reference
  • corr_soil_heat_flow_5
  • wdir_vec_std
  • temp_air_top
  • surface_soil_heat_flux_5
  • soil_moisture_5
  • surface_soil_heat_flux_3
  • surface_soil_heat_flux_4
  • soil_moisture_1
  • soil_moisture_2
  • soil_moisture_3
  • soil_moisture_4
  • temp_trh_top
  • rh_bottom_fraction
  • home_signal_15
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_1
  • sensible_heat_flux
  • surface_soil_heat_flux_avg
  • net_radiation
  • soil_heat_capacity_5
  • soil_heat_capacity_4
  • soil_heat_capacity_2
  • soil_heat_capacity_3
  • bowen_ratio
  • home_signal_30
  • soil_heat_capacity_1
  • soil_temp_5
  • soil_temp_4
  • soil_heat_flow_3
  • soil_temp_3
  • soil_heat_flow_2
  • soil_temp_2
  • soil_heat_flow_1
  • soil_temp_1
  • soil_heat_flow_5
  • soil_heat_flow_4
  • temp_air_bottom
  • wdir_vec_mean
  • energy_storage_change_1
  • energy_storage_change_2
  • energy_storage_change_3
  • energy_storage_change_4
  • energy_storage_change_5
  • temp_trh_bottom
  • Barometric Pressure(atmos_pressure)

sgp15ebbrE26.b1:
  • wdir_vec_mean_mv
  • soil_heat_flow_4_mv
  • soil_moisture_2_r
  • soil_heat_flow_3_mv
  • soil_temp_1_rr
  • temp_trh_right_rr
  • soil_heat_flow_2_mv
  • battery_voltage
  • soil_temp_3_rr
  • soil_moisture_4_r
  • soil_heat_flow_1_mv
  • soil_moisture_1_r
  • soil_temp_4_rr
  • temp_trh_left_rr
  • temp_air_left
  • rh_right_mv
  • soil_moisture_3_r
  • home_signal
  • temp_air_right
  • rh_left_mv
  • soil_temp_5_rr
  • soil_heat_flow_5_mv
  • temp_reference_rr
  • soil_moisture_5_r
  • soil_temp_2_rr
  • wspd_arith_mean
  • atmos_pressure_mv
  • net_radiation_mv

sgp5ebbrE26.b1:
  • temp_trh_bottom
  • wspd_arith_mean
  • wdir_vec_std
  • rh_top_fraction
  • home_signal
  • Barometric Pressure(atmos_pressure)
  • rh_bottom_fraction
  • temp_reference
  • wdir_vec_mean
  • temp_trh_top
  • temp_air_top
  • wspd_vec_mean
  • temp_air_bottom
  • vapor_pressure_bottom
  • vapor_pressure_top
  • net_radiation


Back To Table of Contents

DQRID : D000627.10
Start DateStart TimeEnd DateEnd Time
02/26/2000153004/20/20001450
Subject:
SGP/EBBR/E26 - Left Air Temperature Periodically Incorrect
DataStreams:sgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
Description:
Left air temperature periodically was incorrect, causing the indicated measurements
to be incorrect.  The user will need to inspect the data to see when the left air
temperature was incorrect (compare left with right air temperature or with the
humidity probe temperature).
Measurements:sgp30ebbrE26.b1:
  • temp_air_bottom
  • bowen_ratio
  • latent_heat_flux
  • temp_air_top
  • sensible_heat_flux

sgp15ebbrE26.b1:
  • temp_air_left

sgp5ebbrE26.b1:
  • temp_air_top
  • temp_air_bottom


Back To Table of Contents

DQRID : D000627.11
Start DateStart TimeEnd DateEnd Time
03/07/2000090004/20/20001450
Subject:
SGP/EBBR/E26 - Reference Temperature Incorrect
DataStreams:sgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
Description:
The reference temperature sensor did not work during the indicated period,
causing the indicated measurements to be incorrect.
Measurements:sgp30ebbrE26.b1:
  • temp_air_bottom
  • bowen_ratio
  • latent_heat_flux
  • temp_air_top
  • temp_reference
  • sensible_heat_flux

sgp15ebbrE26.b1:
  • temp_air_right
  • temp_reference_rr
  • temp_air_left

sgp5ebbrE26.b1:
  • temp_air_top
  • temp_air_bottom
  • temp_reference


Back To Table of Contents

DQRID : D000627.4
Start DateStart TimeEnd DateEnd Time
03/24/2000010004/06/20001730
Subject:
SGP/EBBR/E26 - Electronics Problem
DataStreams:sgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
Description:
Incorrect home signal indicates an electronic problem that affected the indicated
measurements; this may have been a multiplexer #2 problem as all sensors affected 
are connected to that multiplexer and no sensors on multiplexer #1 were affected.
Measurements:sgp30ebbrE26.b1:
  • temp_air_bottom
  • surface_soil_heat_flux_avg
  • net_radiation
  • temp_air_top
  • surface_soil_heat_flux_5
  • surface_soil_heat_flux_3
  • surface_soil_heat_flux_4
  • bowen_ratio
  • home_signal_30
  • home_signal_15
  • latent_heat_flux
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_1
  • soil_heat_flow_3
  • soil_heat_flow_2
  • soil_heat_flow_1
  • soil_heat_flow_5
  • soil_heat_flow_4
  • sensible_heat_flux
  • corr_soil_heat_flow_4
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_1
  • temp_reference
  • corr_soil_heat_flow_5

sgp15ebbrE26.b1:
  • soil_heat_flow_4_mv
  • soil_heat_flow_5_mv
  • temp_air_left
  • temp_reference_rr
  • soil_heat_flow_2_mv
  • home_signal
  • temp_air_right
  • soil_heat_flow_3_mv
  • soil_heat_flow_1_mv
  • net_radiation_mv

sgp5ebbrE26.b1:
  • home_signal
  • temp_air_top
  • temp_air_bottom
  • temp_reference
  • net_radiation


Back To Table of Contents

DQRID : D000627.6
Start DateStart TimeEnd DateEnd Time
04/06/2000180006/15/20001600
Subject:
SGP/EBBR/E26 - Soil Heat Flow #5 Incorrect
DataStreams:sgp15ebbrE26.b1, sgp30ebbrE26.b1
Description:
Soil Heat Flow #5 was incorrect, causing the indicated measurements to be incorrect.
Measurements:sgp30ebbrE26.b1:
  • surface_soil_heat_flux_avg
  • latent_heat_flux
  • surface_soil_heat_flux_5
  • soil_heat_flow_5
  • corr_soil_heat_flow_5
  • sensible_heat_flux

sgp15ebbrE26.b1:
  • soil_heat_flow_5_mv


Back To Table of Contents

DQRID : D000627.7
Start DateStart TimeEnd DateEnd Time
12/16/1999003003/07/20001455
Subject:
SGP/EBBR/E26 - Soil Heat Flow #1 Incorrect
DataStreams:sgp15ebbrE26.b1, sgp30ebbrE26.b1
Description:
Soil Heat Flow #1 was incorrect, causing the indicated measurements to be incorrect.
A broken sensor wire was at fault.
Measurements:sgp30ebbrE26.b1:
  • surface_soil_heat_flux_avg
  • latent_heat_flux
  • surface_soil_heat_flux_1
  • soil_heat_flow_1
  • corr_soil_heat_flow_1
  • sensible_heat_flux

sgp15ebbrE26.b1:
  • soil_heat_flow_1_mv


Back To Table of Contents

DQRID : D000627.8
Start DateStart TimeEnd DateEnd Time
03/03/2000060003/07/20001455
Subject:
SGP/EBBR/E26 - Soil Heat Flow #2 Large Negative
DataStreams:sgp15ebbrE26.b1, sgp30ebbrE26.b1
Description:
Soil Heat Flow #2 was large negative and incorrect for an unknown reason.
Measurements:sgp30ebbrE26.b1:
  • surface_soil_heat_flux_avg
  • latent_heat_flux
  • surface_soil_heat_flux_2
  • soil_heat_flow_2
  • corr_soil_heat_flow_2
  • sensible_heat_flux

sgp15ebbrE26.b1:
  • soil_heat_flow_2_mv


Back To Table of Contents

DQRID : D000627.9
Start DateStart TimeEnd DateEnd Time
02/25/2000214502/26/20001130
Subject:
SGP/EBBR/E26 - Left Air Temperature Incorrect
DataStreams:sgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
Description:
Incorrect left air temperature caused the indicated measurements to be incorrect.
Measurements:sgp30ebbrE26.b1:
  • temp_air_bottom
  • bowen_ratio
  • latent_heat_flux
  • temp_air_top
  • sensible_heat_flux

sgp15ebbrE26.b1:
  • temp_air_left

sgp5ebbrE26.b1:
  • temp_air_top
  • temp_air_bottom


Back To Table of Contents

DQRID : D010213.10
Start DateStart TimeEnd DateEnd Time
12/13/2000091512/14/20001715
Subject:
SGP/EBBR/E25 - EBBR E25 Wind Speed Iced
DataStreams:sgp15ebbrE25.b1, sgp30ebbrE25.b1, sgp5ebbrE25.b1
Description:
The anemometer was frozen stopped by freezing rain.  Indicated data was incorrect.
Measurements:sgp30ebbrE25.b1:
  • wspd_vec_mean
  • wspd_arith_mean

sgp5ebbrE25.b1:
  • wspd_arith_mean
  • wspd_vec_mean

sgp15ebbrE25.b1:
  • wspd_arith_mean


Back To Table of Contents

DQRID : D010213.11
Start DateStart TimeEnd DateEnd Time
12/25/2000164512/28/20002345
Subject:
SGP/EBBR/E25 - EBBR E25 Wind Speed Iced
DataStreams:sgp15ebbrE25.b1, sgp30ebbrE25.b1, sgp5ebbrE25.b1
Description:
The anemometer was frozen stopped by freezing rain.  Indicated data was incorrect.  The 
end date and time is a guess, based on conditions at surrounding sites (data was missing 
for a few days starting Dec. 27).
Measurements:sgp30ebbrE25.b1:
  • wspd_vec_mean
  • wspd_arith_mean

sgp5ebbrE25.b1:
  • wspd_arith_mean
  • wspd_vec_mean

sgp15ebbrE25.b1:
  • wspd_arith_mean


Back To Table of Contents

DQRID : D010213.12
Start DateStart TimeEnd DateEnd Time
12/25/2000060012/28/20001145
Subject:
SGP/EBBR/E26 - Wind Speed Iced
DataStreams:sgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
Description:
The anemometer was frozen stopped by freezing rain.  Indicated data are incorrect.
Measurements:sgp30ebbrE26.b1:
  • wspd_arith_mean
  • wspd_vec_mean

sgp15ebbrE26.b1:
  • wspd_arith_mean

sgp5ebbrE26.b1:
  • wspd_arith_mean
  • wspd_vec_mean


Back To Table of Contents

DQRID : D010213.8
Start DateStart TimeEnd DateEnd Time
12/25/2000131512/27/20002015
Subject:
SGP/EBBR/E22 - EBBR E22 Wind Speed Iced
DataStreams:sgp15ebbrE22.b1, sgp30ebbrE22.b1, sgp5ebbrE22.b1
Description:
The anemometer was frozen stopped by freezing rain.  Indicated data is incorrect.
Measurements:sgp30ebbrE22.b1:
  • wspd_vec_mean
  • wspd_arith_mean

sgp5ebbrE22.b1:
  • wspd_vec_mean
  • wspd_arith_mean

sgp15ebbrE22.b1:
  • wspd_arith_mean


Back To Table of Contents

DQRID : D010213.9
Start DateStart TimeEnd DateEnd Time
12/11/2000094512/12/20001414
Subject:
SGP/EBBR/E25 - EBBR E25 Wind Speed Iced
DataStreams:sgp15ebbrE25.b1, sgp30ebbrE25.b1, sgp5ebbrE25.b1
Description:
The anemometer was frozen stopped by freezing rain.  Indicated data was incorrect.
Measurements:sgp30ebbrE25.b1:
  • wspd_vec_mean
  • wspd_arith_mean

sgp5ebbrE25.b1:
  • wspd_arith_mean
  • wspd_vec_mean

sgp15ebbrE25.b1:
  • wspd_arith_mean


Back To Table of Contents

DQRID : D010427.11
Start DateStart TimeEnd DateEnd Time
04/05/2000190004/05/20001901
04/05/2000200004/05/20002001
Subject:
SGP EBBR E22 - E22 EBBR Data Incorrect During Logger Replacement
DataStreams:sgp15ebbrE22.b1, sgp30ebbrE22.b1, sgp5ebbrE22.00, sgp5ebbrE22.b1
Description:
The data was incorrect during replacement of the logger.
Measurements:sgp5ebbrE22.00:
  • null(Raw data stream - documentation not supported)

sgp30ebbrE22.b1:
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_1
  • corr_soil_heat_flow_4
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_5
  • vapor_pressure_top
  • sensible_heat_flux
  • temp_reference
  • wspd_arith_mean
  • temp_air_bottom
  • surface_soil_heat_flux_avg
  • temp_trh_top
  • wspd_vec_mean
  • energy_storage_change_1
  • vapor_pressure_bottom
  • home_signal_30
  • latent_heat_flux
  • temp_trh_bottom
  • rh_bottom_fraction
  • bowen_ratio
  • soil_moisture_5
  • net_radiation
  • soil_moisture_1
  • soil_moisture_2
  • soil_moisture_3
  • soil_moisture_4
  • soil_heat_capacity_5
  • soil_heat_capacity_4
  • soil_heat_flow_2
  • soil_heat_capacity_3
  • soil_heat_flow_3
  • soil_heat_capacity_2
  • soil_heat_capacity_1
  • soil_heat_flow_1
  • energy_storage_change_3
  • energy_storage_change_2
  • energy_storage_change_5
  • energy_storage_change_4
  • home_signal_15
  • wdir_vec_std
  • soil_heat_flow_5
  • soil_heat_flow_4
  • soil_temp_5
  • soil_temp_2
  • soil_temp_1
  • soil_temp_4
  • soil_temp_3
  • wdir_vec_mean
  • temp_air_top
  • Barometric Pressure(atmos_pressure)
  • rh_top_fraction
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_1
  • surface_soil_heat_flux_4
  • surface_soil_heat_flux_3
  • surface_soil_heat_flux_5

sgp5ebbrE22.b1:
  • vapor_pressure_bottom
  • temp_trh_top
  • net_radiation
  • rh_bottom_fraction
  • temp_trh_bottom
  • home_signal
  • wspd_arith_mean
  • temp_reference
  • wdir_vec_std
  • wspd_vec_mean
  • vapor_pressure_top
  • wdir_vec_mean
  • temp_air_top
  • rh_top_fraction
  • Barometric Pressure(atmos_pressure)
  • temp_air_bottom

sgp15ebbrE22.b1:
  • temp_trh_right_rr
  • rh_right_mv
  • atmos_pressure_mv
  • soil_moisture_3_rr
  • temp_air_left
  • soil_heat_flow_3_mv
  • home_signal
  • net_radiation_mv
  • temp_reference_rr
  • soil_temp_2_rr
  • soil_temp_1_rr
  • soil_temp_4_rr
  • soil_moisture_2_r
  • temp_air_right
  • soil_moisture_2_rr
  • soil_moisture_4_r
  • soil_moisture_3_r
  • soil_moisture_1_rr
  • soil_moisture_5_r
  • wdir_vec_mean_mv
  • rh_left_mv
  • soil_heat_flow_2_mv
  • wspd_arith_mean
  • soil_heat_flow_5_mv
  • soil_temp_3_rr
  • soil_moisture_1_r
  • soil_heat_flow_4_mv
  • soil_heat_flow_1_mv
  • temp_trh_left_rr
  • soil_moisture_4_rr
  • soil_moisture_5_rr
  • soil_temp_5_rr


Back To Table of Contents

DQRID : D010427.13
Start DateStart TimeEnd DateEnd Time
04/21/2000190004/27/20001031
05/10/2000200006/11/20000531
07/08/2000180010/16/20000231
Subject:
SGP EBBR E22 - E22 EBBR Soil Moisture Lower Than Measurement Capability
DataStreams:sgp15ebbrE22.b1, sgp30ebbrE22.b1
Description:
The indicated measurements were incorrect because soil moisture dropped below (sometimes 
even negative) the ability of the probes to measure it.
Measurements:sgp30ebbrE22.b1:
  • surface_soil_heat_flux_avg
  • soil_moisture_5
  • energy_storage_change_1
  • soil_moisture_1
  • soil_moisture_2
  • soil_moisture_3
  • soil_moisture_4
  • soil_heat_capacity_5
  • soil_heat_capacity_4
  • sensible_heat_flux
  • soil_heat_capacity_3
  • soil_heat_capacity_2
  • soil_heat_capacity_1
  • energy_storage_change_3
  • energy_storage_change_2
  • energy_storage_change_5
  • energy_storage_change_4
  • latent_heat_flux
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_1
  • surface_soil_heat_flux_4
  • surface_soil_heat_flux_3
  • surface_soil_heat_flux_5

sgp15ebbrE22.b1:
  • soil_moisture_4_r
  • soil_moisture_3_r
  • soil_moisture_1_rr
  • soil_moisture_1_r
  • soil_moisture_5_r
  • soil_moisture_3_rr
  • soil_moisture_4_rr
  • soil_moisture_2_r
  • soil_moisture_5_rr
  • soil_moisture_2_rr


Back To Table of Contents

DQRID : D010427.14
Start DateStart TimeEnd DateEnd Time
10/16/2000023510/22/20000316
Subject:
SGP EBBR E22 - E22 EBBR Soil Moisture #3 Lower Than Can Be Measured
DataStreams:sgp15ebbrE22.b1, sgp30ebbrE22.b1
Description:
The soil moisture was too low to be measured correctly by probe #3.
Measurements:sgp30ebbrE22.b1:
  • latent_heat_flux
  • soil_heat_capacity_3
  • sensible_heat_flux
  • energy_storage_change_3
  • surface_soil_heat_flux_avg
  • surface_soil_heat_flux_3
  • soil_moisture_3

sgp15ebbrE22.b1:
  • soil_moisture_3_rr
  • soil_moisture_3_r


Back To Table of Contents

DQRID : D010427.15
Start DateStart TimeEnd DateEnd Time
10/16/2000013010/18/20001841
Subject:
SGP EBBR E22 - E22 EBBR Net Radiation Incorrect
DataStreams:sgp15ebbrE22.b1, sgp30ebbrE22.b1, sgp5ebbrE22.b1
Description:
Water inside the domes of the net radiometer caused measurements from it to be incorrect.  
Calculated latent and sensible heat fluxes were therefore incorrect also.
Measurements:sgp30ebbrE22.b1:
  • latent_heat_flux
  • sensible_heat_flux
  • net_radiation

sgp5ebbrE22.b1:
  • net_radiation

sgp15ebbrE22.b1:
  • net_radiation_mv


Back To Table of Contents

DQRID : D010605.16
Start DateStart TimeEnd DateEnd Time
02/07/2000183002/07/20001831
02/08/2000183002/08/20001831
02/12/2000200002/12/20002001
02/14/2000190002/14/20002001
02/14/2000210002/14/20002101
02/15/2000183002/15/20001901
02/19/2000183002/20/20001831
02/20/2000193002/20/20002201
02/27/2000193002/27/20001931
02/27/2000220002/27/20002201
03/04/2000193003/04/20002131
03/05/2000193003/05/20002101
03/06/2000173003/06/20001731
Subject:
SGP EBBR E25 - E25 EBBR Soil Heat Flow #5 Incorrect
DataStreams:sgp15ebbrE25.b1, sgp30ebbrE25.b1
Description:
Soil Heat Flow probe #5 gave incorrect measurements; the measurements were
either too low or low offscale.  Average soil heat flow, sensible heat flux, and latent 
heat flux were therefore also incorrect, but can be calculated from the
remaining correct soil heat flows.
Measurements:sgp30ebbrE25.b1:
  • latent_heat_flux
  • corr_soil_heat_flow_5
  • soil_heat_flow_5
  • surface_soil_heat_flux_5
  • surface_soil_heat_flux_avg
  • sensible_heat_flux

sgp15ebbrE25.b1:
  • soil_heat_flow_5_mv


Back To Table of Contents

DQRID : D010605.17
Start DateStart TimeEnd DateEnd Time
11/03/2000020011/08/20001301
11/08/2000133011/08/20002301
11/09/2000160011/10/20000201
11/10/2000153011/11/20000301
11/11/2000150011/13/20000301
11/13/2000163011/14/20000331
11/14/2000153011/15/20000201
11/15/2000143011/16/20001331
11/16/2000143011/17/20000430
11/17/2000153011/18/20000101
11/18/2000140011/19/20000430
11/19/2000150011/20/20000301
11/20/2000150011/21/20000001
11/21/2000150002/07/20011731
Subject:
SGP EBBR E25 - E25 EBBR Soil Heat Flow #3 Incorrect
DataStreams:sgp15ebbrE25.b1, sgp30ebbrE25.b1
Description:
Soil Heat Flow #3 was frequently too small or large negative.
Average soil heat flow, sensible heat flux, and latent heat flux were
also incorrect during these times; these can be re-calculated from the 
remaining correct soil heat flows.
Measurements:sgp30ebbrE25.b1:
  • latent_heat_flux
  • soil_heat_flow_3
  • corr_soil_heat_flow_3
  • surface_soil_heat_flux_3
  • surface_soil_heat_flux_avg
  • sensible_heat_flux

sgp15ebbrE25.b1:
  • soil_heat_flow_3_mv


Back To Table of Contents

DQRID : D010605.18
Start DateStart TimeEnd DateEnd Time
11/23/2000024511/29/20001631
12/03/2000193012/13/20001746
Subject:
SGP EBBR E25 - E25 EBBR Left Aspirator Not Working
DataStreams:sgp15ebbrE25.b1, sgp30ebbrE25.b1, sgp5ebbrE25.b1
Description:
The left aspirator unit of the AEM was not working.  Therefore the 
indicated measurements are incorrect.
Measurements:sgp30ebbrE25.b1:
  • rh_top_fraction
  • temp_air_bottom
  • temp_air_top
  • sensible_heat_flux
  • latent_heat_flux
  • vapor_pressure_bottom
  • rh_bottom_fraction
  • bowen_ratio
  • temp_trh_top
  • temp_trh_bottom
  • vapor_pressure_top

sgp5ebbrE25.b1:
  • vapor_pressure_top
  • rh_top_fraction
  • temp_air_bottom
  • temp_air_top
  • temp_trh_bottom
  • vapor_pressure_bottom
  • rh_bottom_fraction
  • temp_trh_top

sgp15ebbrE25.b1:
  • rh_left_mv
  • temp_air_left
  • temp_trh_left_rr


Back To Table of Contents

DQRID : D010605.19
Start DateStart TimeEnd DateEnd Time
10/01/2000000012/21/20001701
Subject:
SGP EBBR E25 - E25 EBBR Soil Heat Flow #1 Incorrect
DataStreams:sgp15ebbrE25.b1, sgp30ebbrE25.b1
Description:
Soil Heat Flow #1 was always positive and therefore incorrect.
Average soil heat flow, sensible heat flux, and latent heat flux 
were therefore incorrect also.
Measurements:sgp30ebbrE25.b1:
  • soil_heat_flow_1
  • latent_heat_flux
  • surface_soil_heat_flux_1
  • corr_soil_heat_flow_1
  • surface_soil_heat_flux_avg
  • sensible_heat_flux

sgp15ebbrE25.b1:
  • soil_heat_flow_1_mv


Back To Table of Contents

DQRID : D010605.20
Start DateStart TimeEnd DateEnd Time
03/03/2000060003/07/20000901
03/24/2000010004/06/20001701
06/19/2000083006/19/20001431
06/19/2000163006/19/20001731
06/19/2000190006/19/20001901
06/20/2000143006/20/20002201
06/30/2000094506/30/20001346
07/02/2000093007/02/20001601
07/03/2000123007/03/20001316
Subject:
SGP EBBR E26 - Data Suspect, Low Battery Voltage
DataStreams:sgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.00, sgp5ebbrE26.b1
Description:
The data measurements are suspect because of low battery voltage.
Some measurements may be correct, but most are probably incorrect.
Large home signals indicate very low battery voltage is present.
Measurements:sgp30ebbrE26.b1:
  • wspd_vec_mean
  • rh_top_fraction
  • wspd_arith_mean
  • latent_heat_flux
  • vapor_pressure_top
  • vapor_pressure_bottom
  • corr_soil_heat_flow_4
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_1
  • temp_reference
  • corr_soil_heat_flow_5
  • wdir_vec_std
  • temp_air_top
  • surface_soil_heat_flux_5
  • soil_moisture_5
  • surface_soil_heat_flux_3
  • surface_soil_heat_flux_4
  • soil_moisture_1
  • soil_moisture_2
  • soil_moisture_3
  • soil_moisture_4
  • temp_trh_top
  • rh_bottom_fraction
  • home_signal_15
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_1
  • sensible_heat_flux
  • surface_soil_heat_flux_avg
  • net_radiation
  • soil_heat_capacity_5
  • soil_heat_capacity_4
  • soil_heat_capacity_2
  • soil_heat_capacity_3
  • bowen_ratio
  • home_signal_30
  • soil_heat_capacity_1
  • soil_temp_5
  • soil_temp_4
  • soil_heat_flow_3
  • soil_temp_3
  • soil_heat_flow_2
  • soil_temp_2
  • soil_heat_flow_1
  • soil_temp_1
  • soil_heat_flow_5
  • soil_heat_flow_4
  • temp_air_bottom
  • wdir_vec_mean
  • energy_storage_change_1
  • energy_storage_change_2
  • energy_storage_change_3
  • energy_storage_change_4
  • energy_storage_change_5
  • temp_trh_bottom
  • Barometric Pressure(atmos_pressure)

sgp15ebbrE26.b1:
  • wdir_vec_mean_mv
  • soil_heat_flow_4_mv
  • soil_moisture_2_r
  • soil_moisture_4_rr
  • soil_heat_flow_3_mv
  • soil_temp_1_rr
  • soil_moisture_5_rr
  • temp_trh_right_rr
  • soil_heat_flow_2_mv
  • battery_voltage
  • soil_temp_3_rr
  • soil_moisture_4_r
  • soil_moisture_2_rr
  • soil_heat_flow_1_mv
  • soil_moisture_1_r
  • soil_temp_4_rr
  • temp_trh_left_rr
  • temp_air_left
  • rh_right_mv
  • soil_moisture_3_r
  • soil_moisture_3_rr
  • home_signal
  • soil_moisture_1_rr
  • temp_air_right
  • rh_left_mv
  • soil_temp_5_rr
  • soil_heat_flow_5_mv
  • temp_reference_rr
  • soil_moisture_5_r
  • soil_temp_2_rr
  • wspd_arith_mean
  • atmos_pressure_mv
  • net_radiation_mv

sgp5ebbrE26.b1:
  • temp_trh_bottom
  • wspd_arith_mean
  • wdir_vec_std
  • rh_top_fraction
  • home_signal
  • Barometric Pressure(atmos_pressure)
  • rh_bottom_fraction
  • temp_reference
  • wdir_vec_mean
  • temp_trh_top
  • temp_air_top
  • wspd_vec_mean
  • temp_air_bottom
  • vapor_pressure_bottom
  • vapor_pressure_top
  • net_radiation

sgp5ebbrE26.00:
  • null(Raw data stream - documentation not supported)


Back To Table of Contents

DQRID : D010605.22
Start DateStart TimeEnd DateEnd Time
09/06/2000223009/06/20002231
09/10/2000143009/10/20001431
10/16/2000150010/16/20001501
10/23/2000190010/23/20001901
10/26/2000153010/26/20001601
10/27/2000143010/27/20001501
01/02/2001160001/02/20012201
01/03/2001153001/03/20011631
Subject:
SGP EBBR E26 - All Data Incorrect
DataStreams:sgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.00, sgp5ebbrE26.b1
Description:
All data was incorrect during these periods for unknown reasons.
However, this tends to happen during preventative maintenance
visits if sensors have to be changed out or tested and the 
datalogger program is reloaded, or if the battery voltage is low.
Measurements:sgp30ebbrE26.b1:
  • wspd_vec_mean
  • rh_top_fraction
  • wspd_arith_mean
  • latent_heat_flux
  • vapor_pressure_top
  • vapor_pressure_bottom
  • corr_soil_heat_flow_4
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_1
  • temp_reference
  • corr_soil_heat_flow_5
  • wdir_vec_std
  • temp_air_top
  • surface_soil_heat_flux_5
  • soil_moisture_5
  • surface_soil_heat_flux_3
  • surface_soil_heat_flux_4
  • soil_moisture_1
  • soil_moisture_2
  • soil_moisture_3
  • soil_moisture_4
  • temp_trh_top
  • rh_bottom_fraction
  • home_signal_15
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_1
  • sensible_heat_flux
  • surface_soil_heat_flux_avg
  • net_radiation
  • soil_heat_capacity_5
  • soil_heat_capacity_4
  • soil_heat_capacity_2
  • soil_heat_capacity_3
  • bowen_ratio
  • home_signal_30
  • soil_heat_capacity_1
  • soil_temp_5
  • soil_temp_4
  • soil_heat_flow_3
  • soil_temp_3
  • soil_heat_flow_2
  • soil_temp_2
  • soil_heat_flow_1
  • soil_temp_1
  • soil_heat_flow_5
  • soil_heat_flow_4
  • temp_air_bottom
  • wdir_vec_mean
  • energy_storage_change_1
  • energy_storage_change_2
  • energy_storage_change_3
  • energy_storage_change_4
  • energy_storage_change_5
  • temp_trh_bottom
  • Barometric Pressure(atmos_pressure)

sgp15ebbrE26.b1:
  • wdir_vec_mean_mv
  • soil_heat_flow_4_mv
  • soil_moisture_2_r
  • soil_moisture_4_rr
  • soil_heat_flow_3_mv
  • soil_temp_1_rr
  • soil_moisture_5_rr
  • temp_trh_right_rr
  • soil_heat_flow_2_mv
  • battery_voltage
  • soil_temp_3_rr
  • soil_moisture_4_r
  • soil_moisture_2_rr
  • soil_heat_flow_1_mv
  • soil_moisture_1_r
  • soil_temp_4_rr
  • temp_trh_left_rr
  • temp_air_left
  • rh_right_mv
  • soil_moisture_3_r
  • soil_moisture_3_rr
  • home_signal
  • soil_moisture_1_rr
  • temp_air_right
  • rh_left_mv
  • soil_temp_5_rr
  • soil_heat_flow_5_mv
  • temp_reference_rr
  • soil_moisture_5_r
  • soil_temp_2_rr
  • wspd_arith_mean
  • atmos_pressure_mv
  • net_radiation_mv

sgp5ebbrE26.b1:
  • temp_trh_bottom
  • wspd_arith_mean
  • wdir_vec_std
  • rh_top_fraction
  • home_signal
  • Barometric Pressure(atmos_pressure)
  • rh_bottom_fraction
  • temp_reference
  • wdir_vec_mean
  • temp_trh_top
  • temp_air_top
  • wspd_vec_mean
  • temp_air_bottom
  • vapor_pressure_bottom
  • vapor_pressure_top
  • net_radiation

sgp5ebbrE26.00:
  • null(Raw data stream - documentation not supported)


Back To Table of Contents

DQRID : D010605.23
Start DateStart TimeEnd DateEnd Time
12/16/1999170003/03/20000931
Subject:
SGP EBBR E26 - Soil Heat Flow #1 Incorrect
DataStreams:sgp15ebbrE26.b1, sgp30ebbrE26.b1
Description:
Soil Heat Flow #1 was incorrect because of a bad electronic
connection.  Average surface heat flow, sensible heat flux, and
latent heat flux are incorrect as a result; these can be re-calculated 
by using the remaining correct soil heat flows.
Measurements:sgp30ebbrE26.b1:
  • surface_soil_heat_flux_avg
  • latent_heat_flux
  • surface_soil_heat_flux_1
  • soil_heat_flow_1
  • corr_soil_heat_flow_1
  • sensible_heat_flux

sgp15ebbrE26.b1:
  • soil_heat_flow_1_mv


Back To Table of Contents

DQRID : D010605.24
Start DateStart TimeEnd DateEnd Time
02/18/2000033002/19/20001131
03/04/2000150003/07/20000901
Subject:
SGP EBBR E26 - Soil Heat Flow #2 Incorrect
DataStreams:sgp15ebbrE26.b1, sgp30ebbrE26.b1
Description:
Soil Heat Flow #2 was incorrect.  Average soil heat flow, 
sensible heat flux, and latent heat flux were therefore also
incorrect; these can be re-calculated from the remaining 
correct soil heat flows.
Measurements:sgp30ebbrE26.b1:
  • surface_soil_heat_flux_avg
  • latent_heat_flux
  • surface_soil_heat_flux_2
  • soil_heat_flow_2
  • corr_soil_heat_flow_2
  • sensible_heat_flux

sgp15ebbrE26.b1:
  • soil_heat_flow_2_mv


Back To Table of Contents

DQRID : D010605.25
Start DateStart TimeEnd DateEnd Time
06/15/2000150006/19/20002201
11/05/2000190011/16/20001601
11/30/2000160012/03/20000731
12/14/2000160012/16/20000301
Subject:
SGP EBBR E26 - Soil Heat Flow #3 Incorrect
DataStreams:sgp15ebbrE26.b1, sgp30ebbrE26.b1
Description:
Soil heat Flow #3 was incorrect (large negative).  Therefore
average soil heat flow, sensible heat flux, and latent heat flux were
also incorrect; these can be re-calculated using the remaining
correct soil heat flows.
Measurements:sgp30ebbrE26.b1:
  • surface_soil_heat_flux_avg
  • latent_heat_flux
  • soil_heat_flow_3
  • corr_soil_heat_flow_3
  • surface_soil_heat_flux_3
  • sensible_heat_flux

sgp15ebbrE26.b1:
  • soil_heat_flow_3_mv


Back To Table of Contents

DQRID : D010723.3
Start DateStart TimeEnd DateEnd Time
04/06/2000173002/08/20011546
Subject:
SGP EBBR E26 - Soil Moisture #1 Incorrect
DataStreams:sgp15ebbrE26.b1, sgp30ebbrE26.b1
Description:
Soil Moisture #1 was a constant 33.7 and was incorrect.

Latent and Sensible Heat fluxes were normally minimally affected.
Measurements:sgp30ebbrE26.b1:
  • surface_soil_heat_flux_avg
  • soil_heat_capacity_1
  • latent_heat_flux
  • surface_soil_heat_flux_1
  • soil_heat_flow_1
  • corr_soil_heat_flow_1
  • soil_moisture_1
  • sensible_heat_flux

sgp15ebbrE26.b1:
  • soil_moisture_1_r
  • soil_moisture_1_rr


Back To Table of Contents

DQRID : D010723.4
Start DateStart TimeEnd DateEnd Time
08/23/2000034508/23/20000401
Subject:
SGP EBBR E26 - AEM Inbetween, Data Incorrect
DataStreams:sgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
Description:
While the AEM was inbetween the correct measurement positions the measurements from the 
two levels were incorrect.

The sensible and latent heat fluxes and Bowen ratio were therefore incorrect also.
Measurements:sgp30ebbrE26.b1:
  • temp_air_bottom
  • temp_air_top
  • temp_trh_bottom
  • temp_trh_top
  • rh_top_fraction
  • bowen_ratio
  • rh_bottom_fraction
  • latent_heat_flux
  • sensible_heat_flux
  • vapor_pressure_top
  • vapor_pressure_bottom

sgp15ebbrE26.b1:
  • rh_left_mv
  • temp_trh_left_rr
  • temp_air_left
  • temp_trh_right_rr
  • rh_right_mv
  • temp_air_right

sgp5ebbrE26.b1:
  • temp_trh_top
  • temp_trh_bottom
  • temp_air_top
  • temp_air_bottom
  • rh_top_fraction
  • rh_bottom_fraction
  • vapor_pressure_top
  • vapor_pressure_bottom


Back To Table of Contents

DQRID : D010723.5
Start DateStart TimeEnd DateEnd Time
04/15/2000153002/22/20011535
Subject:
SGP EBBR E26 - Soil Heat Flow #5 Incorrect
DataStreams:sgp15ebbrE26.b1, sgp30ebbrE26.b1
Description:
Soil Heat Flow #5 was large negative during this period.

Therefore, calculated average soil heat flow, latent heat flux, and sensible heat flux 
were incorrect.  These measurements can be recalculated from the use of measurements from 
only soil heat flow sensors #1-4.
Measurements:sgp30ebbrE26.b1:
  • surface_soil_heat_flux_avg
  • latent_heat_flux
  • surface_soil_heat_flux_5
  • soil_heat_flow_5
  • corr_soil_heat_flow_5
  • sensible_heat_flux

sgp15ebbrE26.b1:
  • soil_heat_flow_5_mv


Back To Table of Contents

DQRID : D010723.7
Start DateStart TimeEnd DateEnd Time
10/21/2000213010/21/20002131
Subject:
SGP EBBR E26 - Some Data Incorrect
DataStreams:sgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
Description:
The reference temperature sensor malfunctioned, causing all associated measurements to be 
incorrect.
Measurements:sgp30ebbrE26.b1:
  • temp_air_bottom
  • surface_soil_heat_flux_avg
  • energy_storage_change_1
  • energy_storage_change_2
  • energy_storage_change_3
  • energy_storage_change_4
  • temp_air_top
  • energy_storage_change_5
  • temp_trh_bottom
  • surface_soil_heat_flux_5
  • surface_soil_heat_flux_3
  • surface_soil_heat_flux_4
  • temp_trh_top
  • bowen_ratio
  • latent_heat_flux
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_1
  • soil_temp_5
  • soil_temp_4
  • soil_temp_3
  • soil_temp_2
  • soil_temp_1
  • vapor_pressure_top
  • sensible_heat_flux
  • vapor_pressure_bottom
  • temp_reference

sgp15ebbrE26.b1:
  • soil_temp_4_rr
  • soil_temp_5_rr
  • temp_air_left
  • temp_reference_rr
  • soil_temp_3_rr
  • soil_temp_2_rr
  • temp_air_right
  • soil_temp_1_rr

sgp5ebbrE26.b1:
  • temp_trh_top
  • temp_trh_bottom
  • temp_air_top
  • temp_air_bottom
  • vapor_pressure_top
  • temp_reference
  • vapor_pressure_bottom


Back To Table of Contents

DQRID : D010723.8
Start DateStart TimeEnd DateEnd Time
09/10/2000150009/10/20001501
11/02/2000160011/02/20001601
01/03/2001170001/03/20011701
Subject:
SGP EBBR E26 - Some Data Incorrect
DataStreams:sgp30ebbrE26.b1
Description:
Since soil temperature was not available for the previous half hour, soil energy storage 
could not be calculated properly for the indicated period.  The individual soil heat 
storage from the five soil sets, average soil heat flow, sensible heat flux, and latent heat 
flux are therefore incorrect.
Measurements:sgp30ebbrE26.b1:
  • surface_soil_heat_flux_avg
  • energy_storage_change_1
  • energy_storage_change_2
  • latent_heat_flux
  • energy_storage_change_3
  • energy_storage_change_4
  • surface_soil_heat_flux_2
  • energy_storage_change_5
  • surface_soil_heat_flux_1
  • sensible_heat_flux
  • surface_soil_heat_flux_5
  • surface_soil_heat_flux_3
  • surface_soil_heat_flux_4


Back To Table of Contents

DQRID : D011127.32
Start DateStart TimeEnd DateEnd Time
04/18/2001171504/18/20011821
10/10/2001180010/10/20011857
Subject:
SGP EBBR E22 - E22 EBBR Data Incorrect During 6 Month Checks
DataStreams:sgp15ebbrE22.b1, sgp30ebbrE22.b1, sgp5ebbrE22.b1
Description:
The data was incorrect during the 6 month checks.
Measurements:sgp30ebbrE22.b1:
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_1
  • corr_soil_heat_flow_4
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_5
  • vapor_pressure_top
  • sensible_heat_flux
  • temp_reference
  • wspd_arith_mean
  • temp_air_bottom
  • surface_soil_heat_flux_avg
  • temp_trh_top
  • wspd_vec_mean
  • energy_storage_change_1
  • vapor_pressure_bottom
  • latent_heat_flux
  • temp_trh_bottom
  • rh_bottom_fraction
  • bowen_ratio
  • soil_moisture_5
  • net_radiation
  • soil_moisture_1
  • soil_moisture_2
  • soil_moisture_3
  • soil_moisture_4
  • soil_heat_capacity_5
  • soil_heat_capacity_4
  • soil_heat_flow_2
  • soil_heat_capacity_3
  • soil_heat_flow_3
  • soil_heat_capacity_2
  • soil_heat_capacity_1
  • soil_heat_flow_1
  • energy_storage_change_3
  • energy_storage_change_2
  • energy_storage_change_5
  • energy_storage_change_4
  • wdir_vec_std
  • soil_heat_flow_5
  • soil_heat_flow_4
  • soil_temp_5
  • soil_temp_2
  • soil_temp_1
  • soil_temp_4
  • soil_temp_3
  • wdir_vec_mean
  • temp_air_top
  • Barometric Pressure(atmos_pressure)
  • rh_top_fraction
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_1
  • surface_soil_heat_flux_4
  • surface_soil_heat_flux_3
  • surface_soil_heat_flux_5

sgp5ebbrE22.b1:
  • vapor_pressure_bottom
  • temp_trh_top
  • net_radiation
  • rh_bottom_fraction
  • temp_trh_bottom
  • wspd_arith_mean
  • temp_reference
  • wdir_vec_std
  • wspd_vec_mean
  • vapor_pressure_top
  • wdir_vec_mean
  • temp_air_top
  • rh_top_fraction
  • Barometric Pressure(atmos_pressure)
  • temp_air_bottom

sgp15ebbrE22.b1:
  • temp_trh_right_rr
  • rh_right_mv
  • atmos_pressure_mv
  • soil_moisture_3_rr
  • temp_air_left
  • soil_heat_flow_3_mv
  • net_radiation_mv
  • temp_reference_rr
  • soil_temp_2_rr
  • soil_temp_1_rr
  • soil_temp_4_rr
  • soil_moisture_2_r
  • temp_air_right
  • soil_moisture_2_rr
  • soil_moisture_4_r
  • soil_moisture_3_r
  • soil_moisture_1_rr
  • soil_moisture_5_r
  • wdir_vec_mean_mv
  • rh_left_mv
  • soil_heat_flow_2_mv
  • wspd_arith_mean
  • soil_heat_flow_5_mv
  • soil_temp_3_rr
  • soil_moisture_1_r
  • soil_heat_flow_4_mv
  • soil_heat_flow_1_mv
  • temp_trh_left_rr
  • soil_moisture_4_rr
  • soil_moisture_5_rr
  • soil_temp_5_rr


Back To Table of Contents

DQRID : D011127.33
Start DateStart TimeEnd DateEnd Time
04/04/2001153004/04/20011631
10/17/2001170510/17/20011811
Subject:
SGP EBBR E25 - E25 EBBR Data Incorrect During 6 Month Checks
DataStreams:sgp15ebbrE25.b1, sgp30ebbrE25.b1, sgp5ebbrE25.b1
Description:
The data was incorrect during the 6 month checks.
Measurements:sgp30ebbrE25.b1:
  • soil_heat_capacity_4
  • soil_heat_capacity_3
  • soil_heat_capacity_2
  • soil_heat_capacity_1
  • wspd_vec_mean
  • temp_air_top
  • sensible_heat_flux
  • net_radiation
  • rh_bottom_fraction
  • temp_trh_bottom
  • surface_soil_heat_flux_4
  • surface_soil_heat_flux_5
  • corr_soil_heat_flow_5
  • corr_soil_heat_flow_4
  • surface_soil_heat_flux_1
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_2
  • surface_soil_heat_flux_3
  • corr_soil_heat_flow_1
  • surface_soil_heat_flux_2
  • temp_reference
  • wspd_arith_mean
  • soil_moisture_1
  • soil_moisture_2
  • soil_moisture_3
  • soil_moisture_4
  • wdir_vec_std
  • soil_moisture_5
  • soil_heat_capacity_5
  • rh_top_fraction
  • soil_temp_1
  • wdir_vec_mean
  • soil_temp_2
  • soil_temp_3
  • soil_temp_4
  • soil_temp_5
  • Barometric Pressure(atmos_pressure)
  • energy_storage_change_5
  • latent_heat_flux
  • soil_heat_flow_1
  • soil_heat_flow_2
  • soil_heat_flow_3
  • soil_heat_flow_4
  • soil_heat_flow_5
  • temp_trh_top
  • vapor_pressure_top
  • temp_air_bottom
  • energy_storage_change_4
  • energy_storage_change_3
  • energy_storage_change_2
  • energy_storage_change_1
  • vapor_pressure_bottom
  • bowen_ratio
  • surface_soil_heat_flux_avg

sgp5ebbrE25.b1:
  • wdir_vec_mean
  • rh_top_fraction
  • wspd_vec_mean
  • temp_trh_bottom
  • temp_reference
  • vapor_pressure_bottom
  • vapor_pressure_top
  • Barometric Pressure(atmos_pressure)
  • wspd_arith_mean
  • wdir_vec_std
  • rh_bottom_fraction
  • temp_trh_top
  • net_radiation
  • temp_air_bottom
  • temp_air_top

sgp15ebbrE25.b1:
  • temp_air_right
  • soil_temp_4_rr
  • rh_left_mv
  • net_radiation_mv
  • temp_trh_left_rr
  • soil_moisture_2_r
  • rh_right_mv
  • soil_heat_flow_2_mv
  • soil_heat_flow_4_mv
  • soil_temp_1_rr
  • wspd_arith_mean
  • soil_heat_flow_5_mv
  • atmos_pressure_mv
  • temp_air_left
  • soil_heat_flow_1_mv
  • soil_temp_2_rr
  • wdir_vec_mean_mv
  • temp_trh_right_rr
  • temp_reference_rr
  • soil_temp_5_rr
  • soil_temp_3_rr
  • soil_moisture_3_r
  • soil_moisture_1_r
  • soil_moisture_4_r
  • soil_moisture_5_r
  • soil_heat_flow_3_mv


Back To Table of Contents

DQRID : D011127.34
Start DateStart TimeEnd DateEnd Time
04/05/2001141504/05/20011546
10/16/2001175010/16/20011921
Subject:
SGP EBBR E26 - Data Incorrect During 6 Month Checks
DataStreams:sgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
Description:
The data was incorrect during the 6 month checks.
Measurements:sgp30ebbrE26.b1:
  • wspd_vec_mean
  • rh_top_fraction
  • wspd_arith_mean
  • latent_heat_flux
  • vapor_pressure_top
  • vapor_pressure_bottom
  • corr_soil_heat_flow_4
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_1
  • temp_reference
  • corr_soil_heat_flow_5
  • wdir_vec_std
  • temp_air_top
  • surface_soil_heat_flux_5
  • soil_moisture_5
  • surface_soil_heat_flux_3
  • surface_soil_heat_flux_4
  • soil_moisture_1
  • soil_moisture_2
  • soil_moisture_3
  • soil_moisture_4
  • temp_trh_top
  • rh_bottom_fraction
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_1
  • sensible_heat_flux
  • surface_soil_heat_flux_avg
  • net_radiation
  • soil_heat_capacity_5
  • soil_heat_capacity_4
  • soil_heat_capacity_2
  • soil_heat_capacity_3
  • bowen_ratio
  • soil_heat_capacity_1
  • soil_temp_5
  • soil_temp_4
  • soil_heat_flow_3
  • soil_heat_flow_2
  • soil_temp_3
  • soil_heat_flow_1
  • soil_temp_2
  • soil_temp_1
  • soil_heat_flow_5
  • soil_heat_flow_4
  • temp_air_bottom
  • wdir_vec_mean
  • energy_storage_change_1
  • energy_storage_change_2
  • energy_storage_change_3
  • energy_storage_change_4
  • energy_storage_change_5
  • temp_trh_bottom
  • Barometric Pressure(atmos_pressure)

sgp15ebbrE26.b1:
  • wdir_vec_mean_mv
  • soil_heat_flow_4_mv
  • soil_moisture_2_r
  • soil_moisture_4_rr
  • soil_heat_flow_3_mv
  • soil_temp_1_rr
  • soil_moisture_5_rr
  • temp_trh_right_rr
  • soil_heat_flow_2_mv
  • soil_temp_3_rr
  • soil_moisture_4_r
  • soil_moisture_2_rr
  • soil_heat_flow_1_mv
  • soil_moisture_1_r
  • soil_temp_4_rr
  • temp_trh_left_rr
  • temp_air_left
  • rh_right_mv
  • soil_moisture_3_r
  • soil_moisture_3_rr
  • soil_moisture_1_rr
  • temp_air_right
  • rh_left_mv
  • soil_temp_5_rr
  • soil_heat_flow_5_mv
  • temp_reference_rr
  • soil_moisture_5_r
  • soil_temp_2_rr
  • wspd_arith_mean
  • atmos_pressure_mv
  • net_radiation_mv

sgp5ebbrE26.b1:
  • temp_trh_bottom
  • wspd_arith_mean
  • wdir_vec_std
  • rh_top_fraction
  • Barometric Pressure(atmos_pressure)
  • rh_bottom_fraction
  • temp_reference
  • wdir_vec_mean
  • temp_trh_top
  • temp_air_top
  • wspd_vec_mean
  • temp_air_bottom
  • vapor_pressure_bottom
  • vapor_pressure_top
  • net_radiation


Back To Table of Contents

DQRID : D011206.1
Start DateStart TimeEnd DateEnd Time
09/14/2000113003/31/20012356
Subject:
SGP EBBR E26 - Low Battery Voltage
DataStreams:sgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
Description:
During the indicated the period the battery voltage often dropped 
to 10.4 volts or below.  At voltages less than 10.5 volts none of
the selected measurements can be considered to be correct.  The battery
charging capacity was insufficient to maintain voltage at night.

If the battery voltage is less than 10.5 volts (see battery voltage in the
15 minute data files), do not use the data.
Measurements:sgp30ebbrE26.b1:
  • wspd_vec_mean
  • rh_top_fraction
  • wspd_arith_mean
  • latent_heat_flux
  • vapor_pressure_top
  • vapor_pressure_bottom
  • corr_soil_heat_flow_4
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_1
  • temp_reference
  • corr_soil_heat_flow_5
  • wdir_vec_std
  • temp_air_top
  • surface_soil_heat_flux_5
  • soil_moisture_5
  • surface_soil_heat_flux_3
  • surface_soil_heat_flux_4
  • soil_moisture_1
  • soil_moisture_2
  • soil_moisture_3
  • soil_moisture_4
  • temp_trh_top
  • rh_bottom_fraction
  • home_signal_15
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_1
  • sensible_heat_flux
  • surface_soil_heat_flux_avg
  • net_radiation
  • soil_heat_capacity_5
  • soil_heat_capacity_4
  • soil_heat_capacity_2
  • soil_heat_capacity_3
  • bowen_ratio
  • home_signal_30
  • soil_heat_capacity_1
  • soil_temp_5
  • soil_temp_4
  • soil_heat_flow_3
  • soil_temp_3
  • soil_heat_flow_2
  • soil_temp_2
  • soil_heat_flow_1
  • soil_temp_1
  • soil_heat_flow_5
  • soil_heat_flow_4
  • temp_air_bottom
  • wdir_vec_mean
  • energy_storage_change_1
  • energy_storage_change_2
  • energy_storage_change_3
  • energy_storage_change_4
  • energy_storage_change_5
  • temp_trh_bottom
  • Barometric Pressure(atmos_pressure)

sgp15ebbrE26.b1:
  • wdir_vec_mean_mv
  • soil_heat_flow_4_mv
  • soil_moisture_2_r
  • soil_moisture_4_rr
  • soil_heat_flow_3_mv
  • soil_temp_1_rr
  • soil_moisture_5_rr
  • temp_trh_right_rr
  • soil_heat_flow_2_mv
  • soil_temp_3_rr
  • soil_moisture_4_r
  • soil_moisture_2_rr
  • soil_heat_flow_1_mv
  • soil_moisture_1_r
  • soil_temp_4_rr
  • temp_trh_left_rr
  • temp_air_left
  • rh_right_mv
  • soil_moisture_3_r
  • soil_moisture_3_rr
  • home_signal
  • soil_moisture_1_rr
  • temp_air_right
  • rh_left_mv
  • soil_temp_5_rr
  • soil_heat_flow_5_mv
  • temp_reference_rr
  • soil_moisture_5_r
  • soil_temp_2_rr
  • wspd_arith_mean
  • atmos_pressure_mv
  • net_radiation_mv

sgp5ebbrE26.b1:
  • temp_trh_bottom
  • wspd_arith_mean
  • wdir_vec_std
  • rh_top_fraction
  • home_signal
  • Barometric Pressure(atmos_pressure)
  • rh_bottom_fraction
  • temp_reference
  • wdir_vec_mean
  • temp_trh_top
  • temp_air_top
  • wspd_vec_mean
  • temp_air_bottom
  • vapor_pressure_bottom
  • vapor_pressure_top
  • net_radiation


Back To Table of Contents

DQRID : D011206.11
Start DateStart TimeEnd DateEnd Time
05/30/2001084505/30/20011801
Subject:
SGP EBBR E25 - E25 EBBR Wind Direction Incorrect
DataStreams:sgp30ebbrE25.b1, sgp5ebbrE25.b1
Description:
The wind direction was incorrect at a constant 135 degrees during the indicated period.
Measurements:sgp30ebbrE25.b1:
  • wdir_vec_std
  • wdir_vec_mean
  • wspd_vec_mean

sgp5ebbrE25.b1:
  • wdir_vec_mean
  • wspd_vec_mean
  • wdir_vec_std


Back To Table of Contents

DQRID : D011206.12
Start DateStart TimeEnd DateEnd Time
06/30/2001060507/11/20011631
Subject:
SGP EBBR E25 - E25 EBBR Wind Direction Incorrect
DataStreams:sgp30ebbrE25.b1, sgp5ebbrE25.b1
Description:
The wind direction was incorrect at close to 0 degrees during the indicated period.
The sensor was replaced to resolve the problem.
Measurements:sgp30ebbrE25.b1:
  • wdir_vec_std
  • wdir_vec_mean
  • wspd_vec_mean

sgp5ebbrE25.b1:
  • wdir_vec_mean
  • wspd_vec_mean
  • wdir_vec_std


Back To Table of Contents

DQRID : D011206.2
Start DateStart TimeEnd DateEnd Time
04/01/2001000008/23/20011530
Subject:
SGP EBBR E26 - Battery Voltage Low
DataStreams:sgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
Description:
The battery voltage often dropped below 10.5 volts. 

All data for voltages below 10.5 volts should be considered to be incorrect.

See the 15 minute data files, which contain the battery voltage, to 
determine when the data was incorrect.
Measurements:sgp30ebbrE26.b1:
  • wspd_vec_mean
  • rh_top_fraction
  • wspd_arith_mean
  • latent_heat_flux
  • vapor_pressure_top
  • vapor_pressure_bottom
  • corr_soil_heat_flow_4
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_1
  • temp_reference
  • corr_soil_heat_flow_5
  • wdir_vec_std
  • temp_air_top
  • surface_soil_heat_flux_5
  • soil_moisture_5
  • surface_soil_heat_flux_3
  • surface_soil_heat_flux_4
  • soil_moisture_1
  • soil_moisture_2
  • soil_moisture_3
  • soil_moisture_4
  • temp_trh_top
  • rh_bottom_fraction
  • home_signal_15
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_1
  • sensible_heat_flux
  • surface_soil_heat_flux_avg
  • net_radiation
  • soil_heat_capacity_5
  • soil_heat_capacity_4
  • soil_heat_capacity_2
  • soil_heat_capacity_3
  • bowen_ratio
  • home_signal_30
  • soil_heat_capacity_1
  • soil_temp_5
  • soil_temp_4
  • soil_heat_flow_3
  • soil_temp_3
  • soil_heat_flow_2
  • soil_temp_2
  • soil_heat_flow_1
  • soil_temp_1
  • soil_heat_flow_5
  • soil_heat_flow_4
  • temp_air_bottom
  • wdir_vec_mean
  • energy_storage_change_1
  • energy_storage_change_2
  • energy_storage_change_3
  • energy_storage_change_4
  • energy_storage_change_5
  • temp_trh_bottom
  • Barometric Pressure(atmos_pressure)

sgp15ebbrE26.b1:
  • wdir_vec_mean_mv
  • soil_heat_flow_4_mv
  • soil_moisture_2_r
  • soil_moisture_4_rr
  • soil_heat_flow_3_mv
  • soil_temp_1_rr
  • soil_moisture_5_rr
  • temp_trh_right_rr
  • soil_heat_flow_2_mv
  • soil_temp_3_rr
  • soil_moisture_4_r
  • soil_moisture_2_rr
  • soil_heat_flow_1_mv
  • soil_moisture_1_r
  • soil_temp_4_rr
  • temp_trh_left_rr
  • temp_air_left
  • rh_right_mv
  • soil_moisture_3_r
  • soil_moisture_3_rr
  • home_signal
  • soil_moisture_1_rr
  • temp_air_right
  • rh_left_mv
  • soil_temp_5_rr
  • soil_heat_flow_5_mv
  • temp_reference_rr
  • soil_moisture_5_r
  • soil_temp_2_rr
  • wspd_arith_mean
  • atmos_pressure_mv
  • net_radiation_mv

sgp5ebbrE26.b1:
  • temp_trh_bottom
  • wspd_arith_mean
  • wdir_vec_std
  • rh_top_fraction
  • home_signal
  • Barometric Pressure(atmos_pressure)
  • rh_bottom_fraction
  • temp_reference
  • wdir_vec_mean
  • temp_trh_top
  • temp_air_top
  • wspd_vec_mean
  • temp_air_bottom
  • vapor_pressure_bottom
  • vapor_pressure_top
  • net_radiation


Back To Table of Contents

DQRID : D011206.4
Start DateStart TimeEnd DateEnd Time
03/07/2001200003/07/20012001
Subject:
SGP EBBR E22 - E22 EBBR 30 Minute Data Incorrect After Missing Data
DataStreams:sgp30ebbrE22.b1
Description:
Complete soil temperature information is not available
when the data is missing for the previous half hour.
Since soil temperature difference with time cannot be 
computed properly, the selected calculated quantities are incorrect.
Measurements:sgp30ebbrE22.b1:
  • sensible_heat_flux
  • energy_storage_change_3
  • energy_storage_change_2
  • energy_storage_change_5
  • energy_storage_change_4
  • surface_soil_heat_flux_avg
  • latent_heat_flux
  • energy_storage_change_1
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_1
  • surface_soil_heat_flux_4
  • surface_soil_heat_flux_3
  • surface_soil_heat_flux_5


Back To Table of Contents

DQRID : D011206.6
Start DateStart TimeEnd DateEnd Time
11/15/2000163002/07/20011731
Subject:
SGP EBBR E25 - E25 EBBR Soil Heat Flow #3 Incorrect
DataStreams:sgp15ebbrE25.b1, sgp30ebbrE25.b1
Description:
The selected measurements and calculated quantities were
incorrect because soil heat flow sensor #3 indicated large
negative soil heat flow.
Measurements:sgp30ebbrE25.b1:
  • latent_heat_flux
  • soil_heat_flow_3
  • corr_soil_heat_flow_3
  • surface_soil_heat_flux_3
  • surface_soil_heat_flux_avg
  • sensible_heat_flux

sgp15ebbrE25.b1:
  • soil_heat_flow_3_mv


Back To Table of Contents

DQRID : D011206.7
Start DateStart TimeEnd DateEnd Time
06/01/2000000002/21/20011701
Subject:
SGP EBBR E25 - E25 EBBR Soil Heat Flow #1 Incorrect
DataStreams:sgp15ebbrE25.b1, sgp30ebbrE25.b1
Description:
The #1 soil heat flow sensor developed a +60 W m-2 bias
and thus indicated higher soil heat flows than the other
sensors.  This results in slightly higher sensible and latent heat
fluxes than is correct. The sensor was replaced on 2/21/01.
Measurements:sgp30ebbrE25.b1:
  • soil_heat_flow_1
  • latent_heat_flux
  • surface_soil_heat_flux_1
  • corr_soil_heat_flow_1
  • surface_soil_heat_flux_avg
  • sensible_heat_flux

sgp15ebbrE25.b1:
  • soil_heat_flow_1_mv


Back To Table of Contents

DQRID : D011206.8
Start DateStart TimeEnd DateEnd Time
04/18/2001164504/18/20011701
Subject:
SGP EBBR E25 - E25 EBBR Soil Heat Flow #3 Incorrect
DataStreams:sgp15ebbrE25.b1, sgp30ebbrE25.b1
Description:
Soil heat flow #3 was large negative during the indicated period.
Measurements:sgp30ebbrE25.b1:
  • latent_heat_flux
  • soil_heat_flow_3
  • corr_soil_heat_flow_3
  • surface_soil_heat_flux_3
  • surface_soil_heat_flux_avg
  • sensible_heat_flux

sgp15ebbrE25.b1:
  • soil_heat_flow_3_mv


Back To Table of Contents

DQRID : D011206.9
Start DateStart TimeEnd DateEnd Time
05/13/2001003005/16/20011931
Subject:
SGP EBBR E25 - E25 EBBR Soil Heat Flow #1 Incorrect
DataStreams:sgp15ebbrE25.b1, sgp30ebbrE25.b1
Description:
Soil heat flow #1 was large negative or large positive during the
indicated period.
Measurements:sgp30ebbrE25.b1:
  • soil_heat_flow_1
  • latent_heat_flux
  • surface_soil_heat_flux_1
  • corr_soil_heat_flow_1
  • surface_soil_heat_flux_avg
  • sensible_heat_flux

sgp15ebbrE25.b1:
  • soil_heat_flow_1_mv


Back To Table of Contents

DQRID : D020628.19
Start DateStart TimeEnd DateEnd Time
11/08/1994165011/08/19941800
Subject:
SGP/EBBR/E22 - T/RH Check
DataStreams:sgp15ebbrE22.b1, sgp30ebbrE22.b1, sgp5ebbrE22.b1
Description:
During the month of November 1994, site operations personnel conducted
field comparisons of the temperature and relative humidity sensors in the
EBBRs and the HMI31 portable T/RH meter (with the removable probe).  As is
reflected in the home signal output, the automatic exchange mechanism was
disabled in order to conduct the checks.

Measurements were taken every 5 minutes, for a half hour each in the
aspirated radiation shields (the HMI31 was inserted into the EBBR aspirated
radiation shield to provide the same aspiration as the EBBR sensors
received).  Measurements of aspirator flow were also recorded.  This
information was provided to the mentor.  The mentor then compared the field
checks with the data recorded by the EBBRs.

The periods of data and data fields that are incorrect because of the checks
are listed below.  Times are those at which the data are reported.


Data Fields
5 minute:  tair_top, tair_bot, thum_top, thum_bot, hum_top, hum_bot,
           vp_top, vp_bot
15 minute: rr_thum_r, rr_thum_l, mv_hum_r, mv_hum_l, tair_r, tair_l
30 minute: tair_top, tair_bot, thum_top, thum_bot, hum_top, hum_bot,
           vp_top, vp_bot, bowen, e, h

5 minute:  1650, 1655, 1700, 1705, 1710, 1715, 1720, 1725, 1730, 1735
15 minute: 1700, 1715, 1730, 1745
30 minute: 1700, 1730, 1800

(EDITOR'S NOTE:  The following analysis refers to all EBBRs installed in Nov 1994)

Results of the T/RH comparisons:
The combined accuracy of the HMI31 and EBBR temperature sensors
(thermocouples or PRTDs) is +/- 0.4 degrees C.  The combined accuracy of the
HMI31 and EBBR RH sensors is +/- 4% for RH less than 80%, and +/- 6% for RH
greater than 80%.  The combined accuracy for each pair of EBBR sensors of
the same type is essentially the same as the quantities stated above.

All of the pairs of EBBR sensors show differences that fall within the
stated combined accuracies.  Although this sounds wonderful, a few of the
differences are close to the combined accuracy, which, because of the small
differences in temperature being measured (normally smaller than the
magnitude of the combined accuracy) could lead to some incorrect estimation
of sensible and latent heat flux.  However, unless there would be substantial
differences of calibration slope of two sensors in a pair, the switching of
height of the sensors every 15 minutes by the automatic exchange mechanism
will remove the offset between the sensors.

The comparisons between the EBBR sensors and the HMI31 T/RH meter showed
much larger differences.  The range of differences were: -2.4 to 0.0 degrees
for the thermocouples, -2.1 to 0.1 degrees for the RH probe PRTDs, and -6.6 to
6.7 percent for the RH sensors.  Six Thermocouples indicated differences from
the HMI31 greater than the combined accuracy.  Seven PRTDs indicated
differences from the HMI31 greater than the combined accuracy.  Four RH
sensors indicated differences from the HMI31 greater than the combined
accuracy.  The temperature differences (for both thermocouples and PRTDs)
were nearly all of one sign; the HMI31 indicated the greater temperature,
which may suggest a bias in the HMI31 temperature measurement, even though
a dozen differences of +/- 0.2 degrees were measured.  Four differences of
zero and only one positive difference (out of 40) were measured.  Thirteen of
the 20 RH differences were positive (HMI31 indicating the lower
RH), with the differences near the level of the combined accuracies being
approximately 50% positive and 50% negative.  It does not appear that the
HMI31 has a RH bias.

Plots of EBBR sensor/HMI31 differences as a function of time from the
installation of the individual sensors (a range of 10 to 30 months in the
field) shows no obvious pattern of sensor drift with time.  This is encouraging.
Measurements:sgp30ebbrE22.b1:
  • bowen_ratio
  • temp_trh_top
  • vapor_pressure_bottom
  • vapor_pressure_top
  • sensible_heat_flux
  • temp_air_top
  • temp_air_bottom
  • latent_heat_flux
  • temp_trh_bottom
  • rh_bottom_fraction
  • rh_top_fraction

sgp5ebbrE22.b1:
  • vapor_pressure_bottom
  • vapor_pressure_top
  • rh_bottom_fraction
  • temp_trh_top
  • temp_air_top
  • rh_top_fraction
  • temp_trh_bottom
  • temp_air_bottom

sgp15ebbrE22.b1:
  • temp_trh_right_rr
  • rh_left_mv
  • temp_trh_left_rr
  • rh_right_mv
  • temp_air_left
  • temp_air_right


Back To Table of Contents

DQRID : D020628.5
Start DateStart TimeEnd DateEnd Time
10/11/1995163010/11/19951930
Subject:
SGP/EBBR/E22 - 3-month Check
DataStreams:sgp15ebbrE22.b1, sgp30ebbrE22.b1, sgp5ebbrE22.b1
Description:
During EBBR 3 month checks the Automatic Exchange Mechanism is disabled
(reflected by home signals near zero) so that the two aspirator units can be
placed at the same height.  The measurements during this period, at least,
do not produce correct outputs of bowen ratio (bowen), sensible heat flux (h),
or latent heat flux (e), nor do the air temperature and relative humidity
measurements indicate gradients.  Checks performed before or after the AEM
is disabled also lead to some incorrect data.
Measurements:sgp30ebbrE22.b1:
  • bowen_ratio
  • temp_trh_top
  • vapor_pressure_bottom
  • vapor_pressure_top
  • sensible_heat_flux
  • temp_air_top
  • temp_air_bottom
  • latent_heat_flux
  • temp_trh_bottom
  • rh_bottom_fraction
  • rh_top_fraction

sgp5ebbrE22.b1:
  • vapor_pressure_bottom
  • vapor_pressure_top
  • rh_bottom_fraction
  • temp_trh_top
  • temp_air_top
  • rh_top_fraction
  • temp_trh_bottom
  • temp_air_bottom

sgp15ebbrE22.b1:
  • temp_trh_right_rr
  • rh_left_mv
  • temp_trh_left_rr
  • rh_right_mv
  • temp_air_left
  • temp_air_right


Back To Table of Contents

DQRID : D020628.6
Start DateStart TimeEnd DateEnd Time
10/13/1995140010/13/19951700
Subject:
SGP/EBBR/E26 - 3-month Check
DataStreams:sgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
Description:
During EBBR 3 month checks the Automatic Exchange Mechanism is disabled
(reflected by home signals near zero) so that the two aspirator units can be
placed at the same height.  The measurements during this period, at least,
do not produce correct outputs of bowen ratio (bowen), sensible heat flux (h),
or latent heat flux (e), nor do the air temperature and relative humidity
measurements indicate gradients.  Checks performed before or after the AEM
is disabled also lead to some incorrect data.
Measurements:sgp30ebbrE26.b1:
  • temp_air_bottom
  • temp_air_top
  • temp_trh_bottom
  • temp_trh_top
  • rh_top_fraction
  • bowen_ratio
  • rh_bottom_fraction
  • latent_heat_flux
  • sensible_heat_flux
  • vapor_pressure_top
  • vapor_pressure_bottom

sgp15ebbrE26.b1:
  • rh_left_mv
  • temp_trh_left_rr
  • temp_air_left
  • temp_trh_right_rr
  • rh_right_mv
  • temp_air_right

sgp5ebbrE26.b1:
  • temp_trh_top
  • temp_trh_bottom
  • temp_air_top
  • temp_air_bottom
  • rh_top_fraction
  • rh_bottom_fraction
  • vapor_pressure_top
  • vapor_pressure_bottom


Back To Table of Contents

DQRID : D020716.17
Start DateStart TimeEnd DateEnd Time
05/15/2002181005/15/20021846
Subject:
SGP/EBBR/E22 - 6 Month Checks
DataStreams:sgp15ebbrE22.b1, sgp30ebbrE22.b1, sgp5ebbrE22.b1
Description:
The indicated measurements were incorrect during the 6 month checks.
Measurements:sgp30ebbrE22.b1:
  • vapor_pressure_top
  • bowen_ratio
  • sensible_heat_flux
  • temp_air_top
  • temp_trh_top
  • temp_air_bottom
  • latent_heat_flux
  • rh_bottom_fraction
  • temp_trh_bottom
  • rh_top_fraction
  • vapor_pressure_bottom

sgp5ebbrE22.b1:
  • vapor_pressure_top
  • rh_bottom_fraction
  • temp_trh_top
  • vapor_pressure_bottom
  • temp_air_top
  • rh_top_fraction
  • temp_trh_bottom
  • temp_air_bottom

sgp15ebbrE22.b1:
  • temp_air_left
  • temp_air_right


Back To Table of Contents

DQRID : D020716.18
Start DateStart TimeEnd DateEnd Time
05/02/2002150005/02/20021531
Subject:
SGP/EBBR/E26 - 6 Month Checks
DataStreams:sgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
Description:
The indicated measurements were incorrect during the 6 month checks.
Measurements:sgp30ebbrE26.b1:
  • temp_air_bottom
  • temp_trh_top
  • bowen_ratio
  • rh_top_fraction
  • rh_bottom_fraction
  • latent_heat_flux
  • temp_air_top
  • temp_trh_bottom
  • vapor_pressure_top
  • sensible_heat_flux
  • vapor_pressure_bottom

sgp15ebbrE26.b1:
  • temp_air_right
  • temp_air_left

sgp5ebbrE26.b1:
  • temp_trh_top
  • temp_trh_bottom
  • temp_air_top
  • rh_bottom_fraction
  • rh_top_fraction
  • vapor_pressure_top
  • vapor_pressure_bottom
  • temp_air_bottom


Back To Table of Contents

DQRID : D020716.3
Start DateStart TimeEnd DateEnd Time
11/06/1996130011/06/19962300
11/07/1996190111/07/19961930
Subject:
SGP/EBBR/E22 - Annual Calibration Changeout
DataStreams:sgp15ebbrE22.b1, sgp30ebbrE22.b1, sgp5ebbrE22.b1
Description:
On 6 November 1996 the EBBR changeout for annual calibration occurred at 
E22, Cordell, OK.  SEBS unit 7 was removed and unit 3 was installed.  Between 
1300 and 2300 GMT no data or incorrect data was collected; most of the data 
is missing.  Data for half hour 1930 GMT on 7 November is incorrect; 3 month 
calibration checks were being performed.
Measurements:sgp30ebbrE22.b1:
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_1
  • corr_soil_heat_flow_4
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_5
  • base time(base_time)
  • vapor_pressure_top
  • sensible_heat_flux
  • temp_reference
  • wspd_arith_mean
  • temp_air_bottom
  • surface_soil_heat_flux_avg
  • lat(lat)
  • temp_trh_top
  • Dummy altitude for Zeb(alt)
  • wspd_vec_mean
  • lon(lon)
  • energy_storage_change_1
  • vapor_pressure_bottom
  • home_signal_30
  • latent_heat_flux
  • temp_trh_bottom
  • rh_bottom_fraction
  • bowen_ratio
  • soil_moisture_5
  • net_radiation
  • soil_moisture_1
  • soil_moisture_2
  • soil_moisture_3
  • soil_moisture_4
  • soil_heat_capacity_5
  • soil_heat_capacity_4
  • soil_heat_flow_2
  • soil_heat_capacity_3
  • soil_heat_flow_3
  • soil_heat_capacity_2
  • soil_heat_capacity_1
  • soil_heat_flow_1
  • energy_storage_change_3
  • energy_storage_change_2
  • energy_storage_change_5
  • energy_storage_change_4
  • home_signal_15
  • Time offset of tweaks from base_time(time_offset)
  • wdir_vec_std
  • soil_heat_flow_5
  • soil_heat_flow_4
  • soil_temp_5
  • soil_temp_2
  • soil_temp_1
  • soil_temp_4
  • soil_temp_3
  • wdir_vec_mean
  • temp_air_top
  • Barometric Pressure(atmos_pressure)
  • rh_top_fraction
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_1
  • surface_soil_heat_flux_4
  • surface_soil_heat_flux_3
  • surface_soil_heat_flux_5

sgp5ebbrE22.b1:
  • vapor_pressure_bottom
  • temp_trh_top
  • lat(lat)
  • net_radiation
  • rh_bottom_fraction
  • temp_trh_bottom
  • base time(base_time)
  • home_signal
  • wspd_arith_mean
  • temp_reference
  • wdir_vec_std
  • Time offset of tweaks from base_time(time_offset)
  • wspd_vec_mean
  • lon(lon)
  • vapor_pressure_top
  • wdir_vec_mean
  • Dummy altitude for Zeb(alt)
  • temp_air_top
  • rh_top_fraction
  • Barometric Pressure(atmos_pressure)
  • temp_air_bottom

sgp15ebbrE22.b1:
  • battery_voltage
  • temp_trh_right_rr
  • Dummy altitude for Zeb(alt)
  • rh_right_mv
  • atmos_pressure_mv
  • temp_air_left
  • soil_heat_flow_3_mv
  • home_signal
  • base time(base_time)
  • lon(lon)
  • net_radiation_mv
  • temp_reference_rr
  • soil_temp_2_rr
  • soil_temp_1_rr
  • Time offset of tweaks from base_time(time_offset)
  • soil_temp_4_rr
  • soil_moisture_2_r
  • temp_air_right
  • soil_moisture_4_r
  • soil_moisture_3_r
  • soil_moisture_5_r
  • wdir_vec_mean_mv
  • rh_left_mv
  • soil_heat_flow_2_mv
  • wspd_arith_mean
  • soil_heat_flow_5_mv
  • soil_temp_3_rr
  • soil_moisture_1_r
  • soil_heat_flow_4_mv
  • lat(lat)
  • soil_heat_flow_1_mv
  • temp_trh_left_rr
  • soil_temp_5_rr


Back To Table of Contents

DQRID : D020717.34
Start DateStart TimeEnd DateEnd Time
02/07/2002184502/07/20021901
Subject:
SGP/EBBR/E22 - All Measurements Zero
DataStreams:sgp15ebbrE22.b1, sgp30ebbrE22.b1, sgp5ebbrE22.00, sgp5ebbrE22.b1
Description:
The measurements are often all zero the first period after a CR10 restart, as occurred 
here.
Measurements:sgp5ebbrE22.00:
  • null(Raw data stream - documentation not supported)

sgp30ebbrE22.b1:
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_1
  • corr_soil_heat_flow_4
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_5
  • vapor_pressure_top
  • sensible_heat_flux
  • temp_reference
  • wspd_arith_mean
  • temp_air_bottom
  • surface_soil_heat_flux_avg
  • temp_trh_top
  • wspd_vec_mean
  • energy_storage_change_1
  • vapor_pressure_bottom
  • home_signal_30
  • latent_heat_flux
  • temp_trh_bottom
  • rh_bottom_fraction
  • bowen_ratio
  • soil_moisture_5
  • net_radiation
  • soil_moisture_1
  • soil_moisture_2
  • soil_moisture_3
  • soil_moisture_4
  • soil_heat_capacity_5
  • soil_heat_capacity_4
  • soil_heat_flow_2
  • soil_heat_capacity_3
  • soil_heat_flow_3
  • soil_heat_capacity_2
  • soil_heat_capacity_1
  • soil_heat_flow_1
  • energy_storage_change_3
  • energy_storage_change_2
  • energy_storage_change_5
  • energy_storage_change_4
  • home_signal_15
  • wdir_vec_std
  • soil_heat_flow_5
  • soil_heat_flow_4
  • soil_temp_5
  • soil_temp_2
  • soil_temp_1
  • soil_temp_4
  • soil_temp_3
  • wdir_vec_mean
  • temp_air_top
  • Barometric Pressure(atmos_pressure)
  • rh_top_fraction
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_1
  • surface_soil_heat_flux_4
  • surface_soil_heat_flux_3
  • surface_soil_heat_flux_5

sgp5ebbrE22.b1:
  • vapor_pressure_bottom
  • temp_trh_top
  • net_radiation
  • rh_bottom_fraction
  • temp_trh_bottom
  • home_signal
  • wspd_arith_mean
  • temp_reference
  • wdir_vec_std
  • wspd_vec_mean
  • vapor_pressure_top
  • wdir_vec_mean
  • temp_air_top
  • rh_top_fraction
  • Barometric Pressure(atmos_pressure)
  • temp_air_bottom

sgp15ebbrE22.b1:
  • battery_voltage
  • temp_trh_right_rr
  • rh_right_mv
  • atmos_pressure_mv
  • soil_moisture_3_rr
  • temp_air_left
  • soil_heat_flow_3_mv
  • home_signal
  • net_radiation_mv
  • temp_reference_rr
  • soil_temp_2_rr
  • soil_temp_1_rr
  • soil_temp_4_rr
  • temp_air_right
  • soil_moisture_2_rr
  • soil_moisture_1_rr
  • wdir_vec_mean_mv
  • rh_left_mv
  • soil_heat_flow_2_mv
  • wspd_arith_mean
  • soil_heat_flow_5_mv
  • soil_temp_3_rr
  • soil_heat_flow_4_mv
  • soil_heat_flow_1_mv
  • temp_trh_left_rr
  • soil_moisture_4_rr
  • soil_moisture_5_rr
  • soil_temp_5_rr


Back To Table of Contents

DQRID : D020717.35
Start DateStart TimeEnd DateEnd Time
12/17/2001123001/09/20021531
01/09/2002154501/12/20020001
01/12/2002051501/15/20020031
02/08/2002084502/08/20022031
02/08/2002214502/14/20022001
02/14/2002201502/16/20021531
02/16/2002194502/17/20020001
02/17/2002041502/20/20020531
02/20/2002081502/20/20021831
02/28/2002103003/06/20021901
04/21/2002200005/29/20021831
Subject:
SGP/EBBR/E22 - AEM Hung or High Home Signals
DataStreams:sgp15ebbrE22.b1, sgp30ebbrE22.b1, sgp5ebbrE22.b1
Description:
The automatic exchange mechanism hung some times and continued to switch at other times, 
although with high home signal values.  If home signal values are not in the proper 
ranges, the gradient calculation is not performed properly by the CR10 program.  Affected flux 
measurements cannot be recalculated.
Measurements:sgp30ebbrE22.b1:
  • vapor_pressure_top
  • bowen_ratio
  • sensible_heat_flux
  • temp_air_top
  • temp_trh_top
  • temp_air_bottom
  • latent_heat_flux
  • rh_bottom_fraction
  • temp_trh_bottom
  • rh_top_fraction
  • vapor_pressure_bottom

sgp5ebbrE22.b1:
  • vapor_pressure_top
  • rh_bottom_fraction
  • temp_trh_top
  • vapor_pressure_bottom
  • temp_air_top
  • rh_top_fraction
  • temp_trh_bottom
  • temp_air_bottom

sgp15ebbrE22.b1:
  • temp_air_left
  • temp_air_right


Back To Table of Contents

DQRID : D020717.36
Start DateStart TimeEnd DateEnd Time
02/15/2002221504/08/20021431
Subject:
SGP/EBBR/E25 - Reprocess: Soil Heat Flow #5 Negative Offset
DataStreams:sgp30ebbrE25.b1
Description:
Soil heat flow 5 was either too large negative or negative when it should have been 
positive; the cause of the negative offset is unknown, but is often the result of a failed 
J-panel over-voltage protection device.

Average soil heat flow, sensible heat flux, and latent heat flux were affected; these can 
be recalculated using the remaining good sets of soil sensors as follows:

ave_shf = (g1 + g2 + g3 + g4)/4

e = -(q + ave_shf)/(1 + bowen)

h = -(q + e + ave_shf)
Measurements:sgp30ebbrE25.b1:
  • latent_heat_flux
  • corr_soil_heat_flow_5
  • soil_heat_flow_5
  • surface_soil_heat_flux_5
  • surface_soil_heat_flux_avg
  • sensible_heat_flux


Back To Table of Contents

DQRID : D020717.37
Start DateStart TimeEnd DateEnd Time
05/30/2002150005/30/20021501
Subject:
SGP/EBBR/E26 - Measurements Zero
DataStreams:sgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.00, sgp5ebbrE26.b1
Description:
The measurements are often zero after a CR10 datalogger restart, as occurred here.
Measurements:sgp30ebbrE26.b1:
  • wspd_vec_mean
  • rh_top_fraction
  • wspd_arith_mean
  • latent_heat_flux
  • vapor_pressure_top
  • vapor_pressure_bottom
  • corr_soil_heat_flow_4
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_1
  • temp_reference
  • corr_soil_heat_flow_5
  • wdir_vec_std
  • temp_air_top
  • surface_soil_heat_flux_5
  • soil_moisture_5
  • surface_soil_heat_flux_3
  • surface_soil_heat_flux_4
  • soil_moisture_1
  • soil_moisture_2
  • soil_moisture_3
  • soil_moisture_4
  • temp_trh_top
  • rh_bottom_fraction
  • home_signal_15
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_1
  • sensible_heat_flux
  • surface_soil_heat_flux_avg
  • net_radiation
  • soil_heat_capacity_5
  • soil_heat_capacity_4
  • soil_heat_capacity_2
  • soil_heat_capacity_3
  • bowen_ratio
  • home_signal_30
  • soil_heat_capacity_1
  • soil_temp_5
  • soil_temp_4
  • soil_heat_flow_3
  • soil_temp_3
  • soil_heat_flow_2
  • soil_temp_2
  • soil_heat_flow_1
  • soil_temp_1
  • soil_heat_flow_5
  • soil_heat_flow_4
  • temp_air_bottom
  • wdir_vec_mean
  • energy_storage_change_1
  • energy_storage_change_2
  • energy_storage_change_3
  • energy_storage_change_4
  • energy_storage_change_5
  • temp_trh_bottom
  • Barometric Pressure(atmos_pressure)

sgp15ebbrE26.b1:
  • wdir_vec_mean_mv
  • soil_heat_flow_4_mv
  • soil_moisture_4_rr
  • soil_heat_flow_3_mv
  • soil_temp_1_rr
  • soil_moisture_5_rr
  • temp_trh_right_rr
  • soil_heat_flow_2_mv
  • battery_voltage
  • soil_temp_3_rr
  • soil_moisture_2_rr
  • soil_heat_flow_1_mv
  • soil_temp_4_rr
  • temp_trh_left_rr
  • temp_air_left
  • rh_right_mv
  • soil_moisture_3_rr
  • home_signal
  • soil_moisture_1_rr
  • temp_air_right
  • rh_left_mv
  • soil_temp_5_rr
  • soil_heat_flow_5_mv
  • temp_reference_rr
  • soil_temp_2_rr
  • wspd_arith_mean
  • atmos_pressure_mv
  • net_radiation_mv

sgp5ebbrE26.b1:
  • temp_trh_bottom
  • wspd_arith_mean
  • wdir_vec_std
  • rh_top_fraction
  • home_signal
  • Barometric Pressure(atmos_pressure)
  • rh_bottom_fraction
  • temp_reference
  • wdir_vec_mean
  • temp_trh_top
  • temp_air_top
  • wspd_vec_mean
  • temp_air_bottom
  • vapor_pressure_bottom
  • vapor_pressure_top
  • net_radiation

sgp5ebbrE26.00:
  • null(Raw data stream - documentation not supported)


Back To Table of Contents

DQRID : D020717.38
Start DateStart TimeEnd DateEnd Time
05/30/2002153005/30/20021531
Subject:
SGP/EBBR/E26 - Measurements Incorrect
DataStreams:sgp30ebbrE26.b1
Description:
Change of energy storage (CES) measurements (calculated from the change of soil 
temperature with time) are sometimes incorrect after a CR10 program restart because the beginning 
measurement of the averaging period is zero.  

Average soil heat flow, sensible heat flux, and latent heat flux were affected and cannot 
be recalculated.
Measurements:sgp30ebbrE26.b1:
  • surface_soil_heat_flux_avg
  • energy_storage_change_1
  • energy_storage_change_2
  • latent_heat_flux
  • energy_storage_change_3
  • energy_storage_change_4
  • surface_soil_heat_flux_2
  • energy_storage_change_5
  • surface_soil_heat_flux_1
  • sensible_heat_flux
  • surface_soil_heat_flux_5
  • surface_soil_heat_flux_3
  • surface_soil_heat_flux_4


Back To Table of Contents

DQRID : D020717.39
Start DateStart TimeEnd DateEnd Time
06/01/2002211506/30/20022356
Subject:
SGP/EBBR/E26 - Multiplexer 2 Failure From High Temperature
DataStreams:sgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
Description:
Multiplexer 2 is failing during times of control box temperatures above 29 degrees C.  The 
failure begins in the last channel and progresses to lower channels as the temperature 
increases.  It has not yet been determined whether the failure is in the relays or a solid 
state component of the multiplexer.  This condition is probably due to the aging of the 
device and the millions of cycles that this 10 year old device has made.  More failures 
of this sort may occur in the future.  A cure is being sought aside from replacement of 
the multiplexers to prevent the problem.

The indicated measurements need to be inspected to determine which ones are usable.
Measurements:sgp30ebbrE26.b1:
  • temp_air_bottom
  • surface_soil_heat_flux_avg
  • bowen_ratio
  • latent_heat_flux
  • temp_air_top
  • soil_heat_flow_3
  • soil_heat_flow_5
  • vapor_pressure_top
  • soil_heat_flow_4
  • sensible_heat_flux
  • vapor_pressure_bottom
  • surface_soil_heat_flux_5
  • corr_soil_heat_flow_4
  • corr_soil_heat_flow_3
  • surface_soil_heat_flux_3
  • surface_soil_heat_flux_4
  • corr_soil_heat_flow_5

sgp15ebbrE26.b1:
  • temp_air_right
  • temp_air_left

sgp5ebbrE26.b1:
  • temp_air_top
  • vapor_pressure_top
  • vapor_pressure_bottom
  • temp_air_bottom


Back To Table of Contents

DQRID : D020724.48
Start DateStart TimeEnd DateEnd Time
07/17/1996140007/17/19961430
Subject:
SGP/EBBR/E26 - Annual Calibration Changeout
DataStreams:sgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
Description:
On 16 November 1996 the EBBR changeout for annual calibration occurred at 
E26, Cement, OK.  SEBS unit 2 was removed and unit 8 was installed.  
Data for half hours 1400 and 1430 GMT on 17 November is 
incorrect; 3 month calibration checks were being performed.
Measurements:sgp30ebbrE26.b1:
  • wspd_vec_mean
  • rh_top_fraction
  • wspd_arith_mean
  • latent_heat_flux
  • vapor_pressure_top
  • vapor_pressure_bottom
  • corr_soil_heat_flow_4
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_1
  • temp_reference
  • corr_soil_heat_flow_5
  • wdir_vec_std
  • temp_air_top
  • surface_soil_heat_flux_5
  • soil_moisture_5
  • surface_soil_heat_flux_3
  • surface_soil_heat_flux_4
  • soil_moisture_1
  • soil_moisture_2
  • soil_moisture_3
  • soil_moisture_4
  • temp_trh_top
  • rh_bottom_fraction
  • home_signal_15
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_1
  • lon(lon)
  • sensible_heat_flux
  • surface_soil_heat_flux_avg
  • net_radiation
  • soil_heat_capacity_5
  • soil_heat_capacity_4
  • soil_heat_capacity_2
  • soil_heat_capacity_3
  • bowen_ratio
  • home_signal_30
  • soil_heat_capacity_1
  • lat(lat)
  • soil_temp_5
  • soil_temp_4
  • soil_heat_flow_3
  • soil_temp_3
  • soil_heat_flow_2
  • soil_temp_2
  • soil_heat_flow_1
  • soil_temp_1
  • soil_heat_flow_5
  • soil_heat_flow_4
  • temp_air_bottom
  • wdir_vec_mean
  • energy_storage_change_1
  • energy_storage_change_2
  • energy_storage_change_3
  • Time offset of tweaks from base_time(time_offset)
  • energy_storage_change_4
  • energy_storage_change_5
  • temp_trh_bottom
  • Dummy altitude for Zeb(alt)
  • Barometric Pressure(atmos_pressure)
  • base time(base_time)

sgp15ebbrE26.b1:
  • wdir_vec_mean_mv
  • soil_heat_flow_4_mv
  • soil_moisture_2_r
  • soil_heat_flow_3_mv
  • soil_temp_1_rr
  • temp_trh_right_rr
  • soil_heat_flow_2_mv
  • battery_voltage
  • lon(lon)
  • soil_temp_3_rr
  • soil_moisture_4_r
  • soil_heat_flow_1_mv
  • soil_moisture_1_r
  • soil_temp_4_rr
  • temp_trh_left_rr
  • lat(lat)
  • temp_air_left
  • Dummy altitude for Zeb(alt)
  • rh_right_mv
  • soil_moisture_3_r
  • home_signal
  • temp_air_right
  • rh_left_mv
  • soil_temp_5_rr
  • soil_heat_flow_5_mv
  • temp_reference_rr
  • Time offset of tweaks from base_time(time_offset)
  • soil_moisture_5_r
  • base time(base_time)
  • soil_temp_2_rr
  • wspd_arith_mean
  • atmos_pressure_mv
  • net_radiation_mv

sgp5ebbrE26.b1:
  • temp_trh_bottom
  • lon(lon)
  • wspd_arith_mean
  • wdir_vec_std
  • rh_top_fraction
  • home_signal
  • Barometric Pressure(atmos_pressure)
  • Time offset of tweaks from base_time(time_offset)
  • rh_bottom_fraction
  • temp_reference
  • wdir_vec_mean
  • temp_trh_top
  • temp_air_top
  • wspd_vec_mean
  • temp_air_bottom
  • vapor_pressure_bottom
  • Dummy altitude for Zeb(alt)
  • vapor_pressure_top
  • net_radiation
  • lat(lat)
  • base time(base_time)


Back To Table of Contents

DQRID : D021113.1
Start DateStart TimeEnd DateEnd Time
04/01/2001000006/18/20032359
Subject:
SGP/EBBR - Incorrect Units for Soil Heat Capacity (cs1, cs2, cs3, cs4, cs5) in 30EBBR 
Header
DataStreams:sgp30ebbrE12.b1, sgp30ebbrE13.b1, sgp30ebbrE15.b1, sgp30ebbrE18.b1, sgp30ebbrE19.b1,
sgp30ebbrE2.b1, sgp30ebbrE20.b1, sgp30ebbrE22.b1, sgp30ebbrE26.b1, sgp30ebbrE4.b1,
sgp30ebbrE7.b1, sgp30ebbrE8.b1, sgp30ebbrE9.b1
Description:
The units for Soil Heat Capacity (cs1, cs2, cs3, cs4, cs5) in the 
EBBR 30 minute netcdf header have been incorrect from the beginning 
of processing the data into netcdf files.  The correct units are 
MJ/m^3/C.

This does not affect the data quality.
Measurements:sgp30ebbrE2.b1:
  • soil_heat_capacity_1
  • soil_heat_capacity_2
  • soil_heat_capacity_3
  • soil_heat_capacity_5
  • soil_heat_capacity_4

sgp30ebbrE26.b1:
  • soil_heat_capacity_5
  • soil_heat_capacity_4
  • soil_heat_capacity_2
  • soil_heat_capacity_3
  • soil_heat_capacity_1

sgp30ebbrE9.b1:
  • soil_heat_capacity_1
  • soil_heat_capacity_2
  • soil_heat_capacity_3
  • soil_heat_capacity_4
  • soil_heat_capacity_5

sgp30ebbrE22.b1:
  • soil_heat_capacity_5
  • soil_heat_capacity_4
  • soil_heat_capacity_3
  • soil_heat_capacity_2
  • soil_heat_capacity_1

sgp30ebbrE13.b1:
  • soil_heat_capacity_1
  • soil_heat_capacity_5
  • soil_heat_capacity_4
  • soil_heat_capacity_3
  • soil_heat_capacity_2

sgp30ebbrE7.b1:
  • soil_heat_capacity_1
  • soil_heat_capacity_2
  • soil_heat_capacity_5
  • soil_heat_capacity_3
  • soil_heat_capacity_4

sgp30ebbrE18.b1:
  • soil_heat_capacity_5
  • soil_heat_capacity_2
  • soil_heat_capacity_1
  • soil_heat_capacity_4
  • soil_heat_capacity_3

sgp30ebbrE12.b1:
  • soil_heat_capacity_2
  • soil_heat_capacity_1
  • soil_heat_capacity_5
  • soil_heat_capacity_4
  • soil_heat_capacity_3

sgp30ebbrE4.b1:
  • soil_heat_capacity_1
  • soil_heat_capacity_2
  • soil_heat_capacity_3
  • soil_heat_capacity_4
  • soil_heat_capacity_5

sgp30ebbrE15.b1:
  • soil_heat_capacity_1
  • soil_heat_capacity_2
  • soil_heat_capacity_3
  • soil_heat_capacity_4
  • soil_heat_capacity_5

sgp30ebbrE19.b1:
  • soil_heat_capacity_4
  • soil_heat_capacity_5
  • soil_heat_capacity_2
  • soil_heat_capacity_3
  • soil_heat_capacity_1

sgp30ebbrE20.b1:
  • soil_heat_capacity_2
  • soil_heat_capacity_3
  • soil_heat_capacity_4
  • soil_heat_capacity_5
  • soil_heat_capacity_1

sgp30ebbrE8.b1:
  • soil_heat_capacity_3
  • soil_heat_capacity_2
  • soil_heat_capacity_5
  • soil_heat_capacity_4
  • soil_heat_capacity_1


Back To Table of Contents

DQRID : D021113.4
Start DateStart TimeEnd DateEnd Time
12/01/1993120006/18/20031159
Subject:
SGP/EBBR - Incorrect Units for Soil Heat Capacity (cs1, cs2, cs3, cs4, cs5) in 30EBBR 
Header
DataStreams:sgp30ebbrE12.b1, sgp30ebbrE13.b1, sgp30ebbrE15.b1, sgp30ebbrE20.b1, sgp30ebbrE22.b1,
sgp30ebbrE26.b1, sgp30ebbrE4.b1, sgp30ebbrE7.b1, sgp30ebbrE8.b1, sgp30ebbrE9.b1
Description:
The units for Soil Heat Capacity (cs1, cs2, cs3, cs4,
cs5) in the EBBR 30 minute netcdf header have been 
incorrect from the beginning of processing the data
into netcdf files.  The correct units are MJ/m^3/C.
   
This does not affect the data quality.

(NOTE: The actual begin date of some of these data streams
 is as early as 7/4/93.  This DQR applies to all 30m EBBR
 data.)
Measurements:sgp30ebbrE26.b1:
  • soil_heat_capacity_5
  • soil_heat_capacity_4
  • soil_heat_capacity_2
  • soil_heat_capacity_3
  • soil_heat_capacity_1

sgp30ebbrE9.b1:
  • soil_heat_capacity_1
  • soil_heat_capacity_2
  • soil_heat_capacity_3
  • soil_heat_capacity_4
  • soil_heat_capacity_5

sgp30ebbrE7.b1:
  • soil_heat_capacity_1
  • soil_heat_capacity_2
  • soil_heat_capacity_5
  • soil_heat_capacity_3
  • soil_heat_capacity_4

sgp30ebbrE4.b1:
  • soil_heat_capacity_1
  • soil_heat_capacity_2
  • soil_heat_capacity_3
  • soil_heat_capacity_4
  • soil_heat_capacity_5

sgp30ebbrE12.b1:
  • soil_heat_capacity_2
  • soil_heat_capacity_1
  • soil_heat_capacity_5
  • soil_heat_capacity_4
  • soil_heat_capacity_3

sgp30ebbrE15.b1:
  • soil_heat_capacity_1
  • soil_heat_capacity_2
  • soil_heat_capacity_3
  • soil_heat_capacity_4
  • soil_heat_capacity_5

sgp30ebbrE22.b1:
  • soil_heat_capacity_5
  • soil_heat_capacity_4
  • soil_heat_capacity_3
  • soil_heat_capacity_2
  • soil_heat_capacity_1

sgp30ebbrE13.b1:
  • soil_heat_capacity_1
  • soil_heat_capacity_5
  • soil_heat_capacity_4
  • soil_heat_capacity_3
  • soil_heat_capacity_2

sgp30ebbrE8.b1:
  • soil_heat_capacity_3
  • soil_heat_capacity_2
  • soil_heat_capacity_5
  • soil_heat_capacity_4
  • soil_heat_capacity_1

sgp30ebbrE20.b1:
  • soil_heat_capacity_2
  • soil_heat_capacity_3
  • soil_heat_capacity_4
  • soil_heat_capacity_5
  • soil_heat_capacity_1


Back To Table of Contents

DQRID : D030110.26
Start DateStart TimeEnd DateEnd Time
11/13/2002190011/13/20021930
Subject:
SGP/EBBR/E22 - Data Incorrect during 6 month checks
DataStreams:sgp15ebbrE22.b1, sgp30ebbrE22.b1, sgp5ebbrE22.b1
Description:
Some of the measurements are incorrect during the 6 month checks.
Measurements:sgp30ebbrE22.b1:
  • vapor_pressure_top
  • bowen_ratio
  • sensible_heat_flux
  • temp_air_top
  • temp_trh_top
  • temp_air_bottom
  • latent_heat_flux
  • rh_bottom_fraction
  • temp_trh_bottom
  • rh_top_fraction
  • vapor_pressure_bottom

sgp5ebbrE22.b1:
  • vapor_pressure_top
  • rh_bottom_fraction
  • temp_trh_top
  • vapor_pressure_bottom
  • temp_air_top
  • rh_top_fraction
  • temp_trh_bottom
  • temp_air_bottom

sgp15ebbrE22.b1:
  • temp_air_left
  • temp_air_right


Back To Table of Contents

DQRID : D030110.27
Start DateStart TimeEnd DateEnd Time
11/27/2002160511/27/20021635
Subject:
SGP/EBBR/E26 - Data Incorrect during 6 month checks
DataStreams:sgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
Description:
Some of the measurements are incorrect during the 6 month checks.
Measurements:sgp30ebbrE26.b1:
  • temp_air_bottom
  • temp_trh_top
  • bowen_ratio
  • rh_top_fraction
  • rh_bottom_fraction
  • latent_heat_flux
  • temp_air_top
  • temp_trh_bottom
  • vapor_pressure_top
  • sensible_heat_flux
  • vapor_pressure_bottom

sgp15ebbrE26.b1:
  • temp_air_right
  • temp_air_left

sgp5ebbrE26.b1:
  • temp_trh_top
  • temp_trh_bottom
  • temp_air_top
  • rh_bottom_fraction
  • rh_top_fraction
  • vapor_pressure_top
  • vapor_pressure_bottom
  • temp_air_bottom


Back To Table of Contents

DQRID : D030117.16
Start DateStart TimeEnd DateEnd Time
09/04/2002171509/04/20021730
10/13/2002123010/13/20021234
10/13/2002130010/15/20021930
10/15/2002214510/15/20021630
Subject:
SGP/EBBR/E22 - AEM Hung between home positions
DataStreams:sgp15ebbrE22.b1, sgp30ebbrE22.b1, sgp5ebbrE22.b1
Description:
When the AEM (Automatic Exchange Mechanism) is hung 
inbetween home positions, the gradients of temperature and 
relative humidity, and thus sensible and latent heat fluxes, 
are incorrect.

There is no work-around to this problem.
Measurements:sgp30ebbrE22.b1:
  • vapor_pressure_top
  • bowen_ratio
  • sensible_heat_flux
  • temp_air_top
  • temp_trh_top
  • temp_air_bottom
  • latent_heat_flux
  • rh_bottom_fraction
  • temp_trh_bottom
  • rh_top_fraction
  • vapor_pressure_bottom

sgp5ebbrE22.b1:
  • vapor_pressure_top
  • rh_bottom_fraction
  • temp_trh_top
  • vapor_pressure_bottom
  • temp_air_top
  • rh_top_fraction
  • temp_trh_bottom
  • temp_air_bottom

sgp15ebbrE22.b1:
  • temp_air_left
  • temp_air_right


Back To Table of Contents

DQRID : D030117.17
Start DateStart TimeEnd DateEnd Time
07/29/2002083008/07/20021800
Subject:
SGP/EBBR/E22 - Water inside Broken Net Rad Dome
DataStreams:sgp30ebbrE22.b1, sgp5ebbrE22.b1
Description:
The net radiation measurement is incorrect. Measurements 
calculated using net radiation are also incorrect.  

No work-around is possible for this situation.
Measurements:sgp30ebbrE22.b1:
  • latent_heat_flux
  • sensible_heat_flux
  • net_radiation

sgp5ebbrE22.b1:
  • net_radiation


Back To Table of Contents

DQRID : D030117.26
Start DateStart TimeEnd DateEnd Time
07/11/2002160007/11/20021629
Subject:
SGP/EBBR/E26 - Measurements zero following logger restart
DataStreams:sgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
Description:
Most of the measurements were zero, which normally happens after a 
datalogger restart.
Measurements:sgp30ebbrE26.b1:
  • wspd_vec_mean
  • rh_top_fraction
  • wspd_arith_mean
  • latent_heat_flux
  • vapor_pressure_top
  • vapor_pressure_bottom
  • corr_soil_heat_flow_4
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_1
  • temp_reference
  • corr_soil_heat_flow_5
  • wdir_vec_std
  • temp_air_top
  • surface_soil_heat_flux_5
  • soil_moisture_5
  • surface_soil_heat_flux_3
  • surface_soil_heat_flux_4
  • soil_moisture_1
  • soil_moisture_2
  • soil_moisture_3
  • soil_moisture_4
  • temp_trh_top
  • rh_bottom_fraction
  • home_signal_15
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_1
  • sensible_heat_flux
  • surface_soil_heat_flux_avg
  • net_radiation
  • soil_heat_capacity_5
  • soil_heat_capacity_4
  • soil_heat_capacity_2
  • soil_heat_capacity_3
  • bowen_ratio
  • home_signal_30
  • soil_heat_capacity_1
  • soil_temp_5
  • soil_temp_4
  • soil_heat_flow_3
  • soil_temp_3
  • soil_heat_flow_2
  • soil_temp_2
  • soil_heat_flow_1
  • soil_temp_1
  • soil_heat_flow_5
  • soil_heat_flow_4
  • temp_air_bottom
  • wdir_vec_mean
  • energy_storage_change_1
  • energy_storage_change_2
  • energy_storage_change_3
  • energy_storage_change_4
  • energy_storage_change_5
  • temp_trh_bottom
  • Barometric Pressure(atmos_pressure)

sgp15ebbrE26.b1:
  • wdir_vec_mean_mv
  • soil_heat_flow_4_mv
  • soil_moisture_4_rr
  • soil_heat_flow_3_mv
  • soil_temp_1_rr
  • soil_moisture_5_rr
  • temp_trh_right_rr
  • soil_heat_flow_2_mv
  • battery_voltage
  • soil_temp_3_rr
  • soil_moisture_2_rr
  • soil_heat_flow_1_mv
  • soil_temp_4_rr
  • temp_trh_left_rr
  • temp_air_left
  • rh_right_mv
  • soil_moisture_3_rr
  • home_signal
  • soil_moisture_1_rr
  • temp_air_right
  • rh_left_mv
  • soil_temp_5_rr
  • soil_heat_flow_5_mv
  • temp_reference_rr
  • soil_temp_2_rr
  • wspd_arith_mean
  • atmos_pressure_mv
  • net_radiation_mv

sgp5ebbrE26.b1:
  • temp_trh_bottom
  • wspd_arith_mean
  • wdir_vec_std
  • rh_top_fraction
  • home_signal
  • Barometric Pressure(atmos_pressure)
  • rh_bottom_fraction
  • temp_reference
  • wdir_vec_mean
  • temp_trh_top
  • temp_air_top
  • wspd_vec_mean
  • temp_air_bottom
  • vapor_pressure_bottom
  • vapor_pressure_top
  • net_radiation


Back To Table of Contents

DQRID : D030117.27
Start DateStart TimeEnd DateEnd Time
07/01/2002000007/11/20021300
Subject:
SGP/EBBR/E26 - Multiplexer Problem
DataStreams:sgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
Description:
One of the multiplexers exhibited dropouts of the channels, beginning
with the last channel at temperatures above about 30 C and moving backward
through the channels as the temperature rose. High temperatures affected the
switching speed of the multiplexer.  This is the first time that this behavior has been 
documented in a Campbell Scientific multiplexer. The multiplexer had
been in continuous field use for 10 years and had experienced probably more
switching cycles than what is normally expected of the device in that period.

The multiplexer was replaced to solve the problem.
Measurements:sgp30ebbrE26.b1:
  • temp_air_bottom
  • surface_soil_heat_flux_avg
  • latent_heat_flux
  • surface_soil_heat_flux_2
  • temp_air_top
  • surface_soil_heat_flux_1
  • sensible_heat_flux
  • surface_soil_heat_flux_5
  • corr_soil_heat_flow_4
  • corr_soil_heat_flow_3
  • surface_soil_heat_flux_3
  • corr_soil_heat_flow_2
  • surface_soil_heat_flux_4
  • corr_soil_heat_flow_1
  • corr_soil_heat_flow_5

sgp15ebbrE26.b1:
  • temp_air_right
  • temp_air_left

sgp5ebbrE26.b1:
  • temp_air_top
  • temp_air_bottom


Back To Table of Contents

DQRID : D030117.28
Start DateStart TimeEnd DateEnd Time
08/27/2002083009/05/20021700
Subject:
SGP/EBBR/E26 - Water in broken Net Radiometer Dome
DataStreams:sgp30ebbrE26.b1, sgp5ebbrE26.b1
Description:
The net radiation measurement is incorrect. Measurements 
calculated using net radiation are also incorrect.  

No work-around is possible for this situation.
Measurements:sgp30ebbrE26.b1:
  • latent_heat_flux
  • net_radiation
  • sensible_heat_flux

sgp5ebbrE26.b1:
  • net_radiation


Back To Table of Contents

DQRID : D030117.29
Start DateStart TimeEnd DateEnd Time
11/01/2002084511/06/20020130
Subject:
SGP/EBBR/E26 - Battery Voltage Low
DataStreams:sgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
Description:
When Battery Voltage drops below 10.5 volts, most 
measurements are suspect and some are often incorrect.

The user will need to inspect the data carefully to 
determine the useability of the data.
Measurements:sgp30ebbrE26.b1:
  • wspd_vec_mean
  • rh_top_fraction
  • wspd_arith_mean
  • latent_heat_flux
  • vapor_pressure_top
  • vapor_pressure_bottom
  • corr_soil_heat_flow_4
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_1
  • temp_reference
  • corr_soil_heat_flow_5
  • wdir_vec_std
  • temp_air_top
  • soil_moisture_5
  • surface_soil_heat_flux_5
  • surface_soil_heat_flux_3
  • surface_soil_heat_flux_4
  • soil_moisture_1
  • soil_moisture_2
  • soil_moisture_3
  • soil_moisture_4
  • temp_trh_top
  • rh_bottom_fraction
  • home_signal_15
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_1
  • sensible_heat_flux
  • surface_soil_heat_flux_avg
  • net_radiation
  • soil_heat_capacity_5
  • soil_heat_capacity_4
  • soil_heat_capacity_2
  • soil_heat_capacity_3
  • bowen_ratio
  • home_signal_30
  • soil_heat_capacity_1
  • soil_temp_5
  • soil_temp_4
  • soil_heat_flow_3
  • soil_temp_3
  • soil_heat_flow_2
  • soil_temp_2
  • soil_heat_flow_1
  • soil_temp_1
  • soil_heat_flow_5
  • soil_heat_flow_4
  • temp_air_bottom
  • wdir_vec_mean
  • energy_storage_change_1
  • energy_storage_change_2
  • energy_storage_change_3
  • energy_storage_change_4
  • energy_storage_change_5
  • temp_trh_bottom
  • Barometric Pressure(atmos_pressure)

sgp15ebbrE26.b1:
  • wdir_vec_mean_mv
  • soil_heat_flow_4_mv
  • soil_moisture_4_rr
  • soil_heat_flow_3_mv
  • soil_temp_1_rr
  • soil_moisture_5_rr
  • temp_trh_right_rr
  • soil_heat_flow_2_mv
  • soil_temp_3_rr
  • soil_moisture_2_rr
  • soil_heat_flow_1_mv
  • soil_temp_4_rr
  • temp_trh_left_rr
  • temp_air_left
  • rh_right_mv
  • soil_moisture_3_rr
  • home_signal
  • soil_moisture_1_rr
  • temp_air_right
  • rh_left_mv
  • soil_temp_5_rr
  • soil_heat_flow_5_mv
  • temp_reference_rr
  • soil_temp_2_rr
  • wspd_arith_mean
  • atmos_pressure_mv
  • net_radiation_mv

sgp5ebbrE26.b1:
  • temp_trh_bottom
  • wdir_vec_std
  • rh_top_fraction
  • home_signal
  • Barometric Pressure(atmos_pressure)
  • rh_bottom_fraction
  • temp_reference
  • wdir_vec_mean
  • temp_trh_top
  • temp_air_top
  • wspd_vec_mean
  • temp_air_bottom
  • vapor_pressure_bottom
  • vapor_pressure_top
  • net_radiation


Back To Table of Contents

DQRID : D030128.2
Start DateStart TimeEnd DateEnd Time
12/04/2002101501/10/20031600
Subject:
SGP/EBBR/E26 - AEM Hung
DataStreams:sgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
Description:
The AEM hung inbetween home positions during the period.  The Bowen ratio, gradient 
measurements, sensible heat flux, and latent heat flux are incorrect.
Measurements:sgp30ebbrE26.b1:
  • temp_air_bottom
  • temp_trh_top
  • bowen_ratio
  • rh_top_fraction
  • rh_bottom_fraction
  • latent_heat_flux
  • temp_air_top
  • temp_trh_bottom
  • vapor_pressure_top
  • sensible_heat_flux
  • vapor_pressure_bottom

sgp15ebbrE26.b1:
  • temp_air_right
  • temp_air_left

sgp5ebbrE26.b1:
  • temp_trh_top
  • temp_trh_bottom
  • temp_air_top
  • rh_bottom_fraction
  • rh_top_fraction
  • vapor_pressure_top
  • vapor_pressure_bottom
  • temp_air_bottom


Back To Table of Contents

DQRID : D030128.3
Start DateStart TimeEnd DateEnd Time
01/10/2003190001/10/20031904
Subject:
SGP/EBBR/E26 - Data zeros following logger restart
DataStreams:sgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
Description:
Most measurements were zero after restart of the CR10 datalogger,
after a calibration changeout of the EBBR unit.
Measurements:sgp30ebbrE26.b1:
  • wspd_vec_mean
  • rh_top_fraction
  • wspd_arith_mean
  • latent_heat_flux
  • vapor_pressure_top
  • vapor_pressure_bottom
  • corr_soil_heat_flow_4
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_1
  • temp_reference
  • corr_soil_heat_flow_5
  • wdir_vec_std
  • temp_air_top
  • surface_soil_heat_flux_5
  • soil_moisture_5
  • surface_soil_heat_flux_3
  • surface_soil_heat_flux_4
  • soil_moisture_1
  • soil_moisture_2
  • soil_moisture_3
  • soil_moisture_4
  • temp_trh_top
  • rh_bottom_fraction
  • home_signal_15
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_1
  • sensible_heat_flux
  • surface_soil_heat_flux_avg
  • net_radiation
  • soil_heat_capacity_5
  • soil_heat_capacity_4
  • soil_heat_capacity_2
  • soil_heat_capacity_3
  • bowen_ratio
  • home_signal_30
  • soil_heat_capacity_1
  • soil_temp_5
  • soil_temp_4
  • soil_heat_flow_3
  • soil_temp_3
  • soil_heat_flow_2
  • soil_temp_2
  • soil_heat_flow_1
  • soil_temp_1
  • soil_heat_flow_5
  • soil_heat_flow_4
  • temp_air_bottom
  • wdir_vec_mean
  • energy_storage_change_1
  • energy_storage_change_2
  • energy_storage_change_3
  • energy_storage_change_4
  • energy_storage_change_5
  • temp_trh_bottom
  • Barometric Pressure(atmos_pressure)

sgp15ebbrE26.b1:
  • wdir_vec_mean_mv
  • soil_heat_flow_4_mv
  • soil_moisture_4_rr
  • soil_heat_flow_3_mv
  • soil_temp_1_rr
  • soil_moisture_5_rr
  • temp_trh_right_rr
  • soil_heat_flow_2_mv
  • battery_voltage
  • soil_temp_3_rr
  • soil_moisture_2_rr
  • soil_heat_flow_1_mv
  • soil_temp_4_rr
  • temp_trh_left_rr
  • temp_air_left
  • rh_right_mv
  • soil_moisture_3_rr
  • home_signal
  • soil_moisture_1_rr
  • temp_air_right
  • rh_left_mv
  • soil_temp_5_rr
  • soil_heat_flow_5_mv
  • temp_reference_rr
  • soil_temp_2_rr
  • wspd_arith_mean
  • atmos_pressure_mv
  • net_radiation_mv

sgp5ebbrE26.b1:
  • temp_trh_bottom
  • wdir_vec_std
  • rh_top_fraction
  • home_signal
  • Barometric Pressure(atmos_pressure)
  • rh_bottom_fraction
  • temp_reference
  • wdir_vec_mean
  • temp_trh_top
  • temp_air_top
  • wspd_vec_mean
  • temp_air_bottom
  • vapor_pressure_bottom
  • vapor_pressure_top
  • net_radiation


Back To Table of Contents

DQRID : D030128.4
Start DateStart TimeEnd DateEnd Time
01/14/2003172501/23/20031715
Subject:
SGP/EBBR/E26 - Left Air Temperature Incorrect
DataStreams:sgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
Description:
The left air temperature was incorrect during the period.  Poor electronic
connections may have caused this.
Measurements:sgp30ebbrE26.b1:
  • temp_air_bottom
  • vapor_pressure_bottom
  • bowen_ratio
  • latent_heat_flux
  • temp_air_top
  • vapor_pressure_top
  • sensible_heat_flux

sgp15ebbrE26.b1:
  • temp_air_left

sgp5ebbrE26.b1:
  • vapor_pressure_bottom
  • temp_air_top
  • temp_air_bottom
  • vapor_pressure_top


Back To Table of Contents

DQRID : D030514.8
Start DateStart TimeEnd DateEnd Time
04/19/2003190005/16/20031500
Subject:
SGP/EBBR/E26 - E26 EBBR Soil Heat Flow #1 Incorrect
DataStreams:sgp15ebbrE26.b1, sgp30ebbrE26.b1
Description:
Soil Heat Flow #1 was incorrect much of the time.

The sensor was replaced.
Measurements:sgp30ebbrE26.b1:
  • surface_soil_heat_flux_avg
  • latent_heat_flux
  • surface_soil_heat_flux_1
  • soil_heat_flow_1
  • corr_soil_heat_flow_1
  • sensible_heat_flux

sgp15ebbrE26.b1:
  • soil_heat_flow_1_mv


Back To Table of Contents

DQRID : D030530.3
Start DateStart TimeEnd DateEnd Time
05/07/2003103006/18/20032359
Subject:
SGP/EBBR/E27  -  E27 EBBR Incorrect Units for Soil Heat Capacity (cs1, cs2, cs3, cs4, cs5) 
in 30EBBR
DataStreams:sgp30ebbrE27.b1
Description:
The units for Soil Heat Capacity (cs1, cs2, cs3, cs4,
   cs5) in the EBBR 30 minute netcdf header have been 
   incorrect from the beginning of processing the data
   into netcdf files.  The correct units are MJ/m^3/C.
   
   This does not affect the data quality.
Measurements:sgp30ebbrE27.b1:
  • soil_heat_capacity_5
  • soil_heat_capacity_3
  • soil_heat_capacity_4
  • soil_heat_capacity_2
  • soil_heat_capacity_1


Back To Table of Contents

DQRID : D030709.1
Start DateStart TimeEnd DateEnd Time
04/01/2001000004/08/20022359
Subject:
SGP/EBBR/E25 - Incorrect Units for Soil Heat Capacity (cs1, cs2, cs3, cs4, cs5) in 30EBBR 
Header
DataStreams:sgp30ebbrE25.b1
Description:
The units for Soil Heat Capacity (cs1, cs2, cs3, cs4, cs5) in the 
EBBR 30 minute netcdf header have been incorrect from the beginning 
of processing the data into netcdf files.  The correct units are 
MJ/m^3/C.

This does not affect the data quality.
Measurements:sgp30ebbrE25.b1:
  • soil_heat_capacity_4
  • soil_heat_capacity_3
  • soil_heat_capacity_2
  • soil_heat_capacity_1
  • soil_heat_capacity_5


Back To Table of Contents

DQRID : D030709.4
Start DateStart TimeEnd DateEnd Time
10/22/1997000004/08/20022359
Subject:
SGP/EBBR/E25  - Incorrect Units for Soil Heat Capacity (cs1, cs2, cs3, cs4, cs5) in 30EBBR 
Header
DataStreams:sgp30baebbrE25.c1, sgp30ebbrE25.b1
Description:
The units for Soil Heat Capacity (cs1, cs2, cs3, cs4,
   cs5) in the EBBR 30 minute netcdf header have been 
   incorrect from the beginning of processing the data
   into netcdf files.  The correct units are MJ/m^3/C.
   
   This does not affect the data quality.

(NOTE: The actual begin date of some of these data
streams is as early as 5/22/97.  This DQR applies to
all 30m EBBR data.)
Measurements:sgp30baebbrE25.c1:
  • Soil heat capacity 1(cs1)
  • Soil heat capacity 2(cs2)
  • Soil heat capacity 5(cs5)
  • Soil heat capacity 4(cs4)
  • Soil heat capacity 3(cs3)

sgp30ebbrE25.b1:
  • soil_heat_capacity_4
  • soil_heat_capacity_3
  • soil_heat_capacity_2
  • soil_heat_capacity_1
  • soil_heat_capacity_5


Back To Table of Contents

DQRID : D030711.2
Start DateStart TimeEnd DateEnd Time
05/07/2003103007/09/20031700
Subject:
SGP/EBBR/E27 - Soil Heat Flow #2 Incorrect
DataStreams:sgp15ebbrE27.b1, sgp30ebbrE27.b1
Description:
Soil Heat Flow sensor #2 was intermittently incorrect at first and then
constantly so later in the period.
Measurements:sgp15ebbrE27.b1:
  • soil_heat_flow_2_mv

sgp30ebbrE27.b1:
  • latent_heat_flux
  • surface_soil_heat_flux_2
  • soil_heat_flow_2
  • sensible_heat_flux
  • corr_soil_heat_flow_2
  • surface_soil_heat_flux_avg


Back To Table of Contents

DQRID : D030711.3
Start DateStart TimeEnd DateEnd Time
06/15/2003010006/23/20031900
06/27/2003103006/27/20031300
06/30/2003003006/30/20030730
06/30/2003100006/30/20032000
07/05/2003040007/10/20030500
07/10/2003143007/20/20030300
07/20/2003173007/21/20030230
07/21/2003193007/22/20030230
07/22/2003173007/23/20030600
07/23/2003163007/23/20031900
Subject:
SGP/EBBR/E27 - Soil Heat Flow #4 Incorrect
DataStreams:sgp15ebbrE27.b1, sgp30ebbrE27.b1
Description:
Soil Heat flow sensor #4 outputs were often very small negative numbers.

See below for a work-around.
Measurements:sgp15ebbrE27.b1:
  • soil_heat_flow_4_mv

sgp30ebbrE27.b1:
  • latent_heat_flux
  • surface_soil_heat_flux_4
  • sensible_heat_flux
  • surface_soil_heat_flux_avg
  • corr_soil_heat_flow_4
  • soil_heat_flow_4


Back To Table of Contents

DQRID : D030711.4
Start DateStart TimeEnd DateEnd Time
05/07/2003103005/15/20031600
05/18/2003180005/28/20031700
Subject:
SGP/EBBR/E27 - Reference T Sensor Failure
DataStreams:sgp15ebbrE27.b1, sgp30ebbrE27.b1, sgp5ebbrE27.b1
Description:
The reference T sensor was not working much of the time, affecting 
all other temperature sensors.  Sensible and latent heat fluxes
were incorrect when this occurred.
Measurements:sgp5ebbrE27.b1:
  • temp_air_top
  • temp_reference
  • temp_air_bottom

sgp15ebbrE27.b1:
  • temp_air_right
  • temp_air_left
  • temp_reference_rr

sgp30ebbrE27.b1:
  • latent_heat_flux
  • temp_reference
  • temp_air_top
  • sensible_heat_flux
  • bowen_ratio
  • temp_air_bottom


Back To Table of Contents

DQRID : D030711.5
Start DateStart TimeEnd DateEnd Time
05/07/2003103006/12/20031800
Subject:
SGP/EBBR/E27 - Wind Direction Hung
DataStreams:sgp15ebbrE27.b1, sgp30ebbrE27.b1, sgp5ebbrE27.b1
Description:
The Wind Direction frequently hung at values in the 70s or 80s.

No other data was affected. Fluxes were not affected.
Measurements:sgp5ebbrE27.b1:
  • wdir_vec_mean
  • wdir_vec_std
  • wspd_vec_mean

sgp15ebbrE27.b1:
  • wdir_vec_mean_mv

sgp30ebbrE27.b1:
  • wdir_vec_mean
  • wdir_vec_std
  • wspd_vec_mean


Back To Table of Contents

DQRID : D030711.6
Start DateStart TimeEnd DateEnd Time
01/24/2003163503/06/20031520
Subject:
SGP/EBBR/E26 -Right Air Temperature Incorrect
DataStreams:sgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
Description:
One of the Right Air Temperature connections was loose, producing incorrect data.
Measurements:sgp30ebbrE26.b1:
  • temp_air_bottom
  • bowen_ratio
  • latent_heat_flux
  • temp_air_top
  • sensible_heat_flux

sgp15ebbrE26.b1:
  • temp_air_right
  • temp_air_left

sgp5ebbrE26.b1:
  • temp_air_top
  • temp_air_bottom


Back To Table of Contents

DQRID : D030711.7
Start DateStart TimeEnd DateEnd Time
01/01/2003000006/25/20031700
Subject:
SGP/EBBR/E22 - home30 too large
DataStreams:sgp15ebbrE22.b1, sgp30ebbrE22.b1, sgp5ebbrE22.b1
Description:
The home30 measurements sometimes exceeded 34.9999, resulting in the
qc flag being set.

However, this does not create any data quality issues.  The qc flag is
set just to provide an alert that the automatic exchange mechanism may have a problem; in 
this case data was not affected.

An electronics repair solved the problem.
Measurements:sgp30ebbrE22.b1:
  • home_signal_30

sgp5ebbrE22.b1:
  • home_signal

sgp15ebbrE22.b1:
  • home_signal


Back To Table of Contents

DQRID : D030712.22
Start DateStart TimeEnd DateEnd Time
04/30/2003172004/30/20031800
Subject:
SGP/EBBR/E22 -  6 Month Checks
DataStreams:sgp15ebbrE22.b1, sgp30ebbrE22.b1, sgp5ebbrE22.b1
Description:
Many measurements were incorrect while the AEM was positioned with both aspirators at the 
same height for comparison checks.
Measurements:sgp30ebbrE22.b1:
  • bowen_ratio
  • temp_trh_top
  • vapor_pressure_bottom
  • vapor_pressure_top
  • sensible_heat_flux
  • temp_air_top
  • temp_air_bottom
  • latent_heat_flux
  • temp_trh_bottom
  • rh_bottom_fraction
  • rh_top_fraction

sgp5ebbrE22.b1:
  • vapor_pressure_bottom
  • vapor_pressure_top
  • rh_bottom_fraction
  • temp_trh_top
  • temp_air_top
  • rh_top_fraction
  • temp_trh_bottom
  • temp_air_bottom

sgp15ebbrE22.b1:
  • temp_trh_right_rr
  • rh_left_mv
  • temp_trh_left_rr
  • rh_right_mv
  • temp_air_left
  • temp_air_right


Back To Table of Contents

DQRID : D030712.23
Start DateStart TimeEnd DateEnd Time
04/17/2003144504/17/20031535
Subject:
SGP/EBBR/E26 -  6 Month Checks
DataStreams:sgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
Description:
Many measurements were incorrect while the AEM was positioned with both aspirators at the 
same height for comparison checks.
Measurements:sgp30ebbrE26.b1:
  • temp_air_bottom
  • temp_air_top
  • temp_trh_bottom
  • temp_trh_top
  • rh_top_fraction
  • bowen_ratio
  • rh_bottom_fraction
  • latent_heat_flux
  • sensible_heat_flux
  • vapor_pressure_top
  • vapor_pressure_bottom

sgp15ebbrE26.b1:
  • rh_left_mv
  • temp_trh_left_rr
  • temp_air_left
  • temp_trh_right_rr
  • rh_right_mv
  • temp_air_right

sgp5ebbrE26.b1:
  • temp_trh_top
  • temp_trh_bottom
  • temp_air_top
  • temp_air_bottom
  • rh_top_fraction
  • rh_bottom_fraction
  • vapor_pressure_top
  • vapor_pressure_bottom


Back To Table of Contents

DQRID : D030712.24
Start DateStart TimeEnd DateEnd Time
05/15/2003160005/15/20031645
Subject:
SGP/EBBR/E27 -  6 Month Checks
DataStreams:sgp15ebbrE27.b1, sgp30ebbrE27.b1, sgp5ebbrE27.b1
Description:
Many measurements were incorrect while the AEM was positioned with both aspirators at the 
same height for comparison checks.
Measurements:sgp5ebbrE27.b1:
  • temp_trh_bottom
  • temp_air_bottom
  • rh_top_fraction
  • temp_air_top
  • rh_bottom_fraction
  • vapor_pressure_top
  • temp_trh_top
  • vapor_pressure_bottom

sgp15ebbrE27.b1:
  • temp_trh_right_rr
  • rh_right_mv
  • temp_air_right
  • temp_air_left
  • rh_left_mv
  • temp_trh_left_rr

sgp30ebbrE27.b1:
  • latent_heat_flux
  • temp_air_top
  • sensible_heat_flux
  • rh_bottom_fraction
  • rh_top_fraction
  • temp_air_bottom
  • temp_trh_bottom
  • temp_trh_top
  • vapor_pressure_top
  • bowen_ratio
  • vapor_pressure_bottom


Back To Table of Contents

DQRID : D030728.4
Start DateStart TimeEnd DateEnd Time
06/12/2003023006/12/20030300
06/13/2003120006/13/20031230
Subject:
SGP/EBBR/E26 - Soil Heat Flow #5 Large Positive
DataStreams:sgp15ebbrE26.b1, sgp30ebbrE26.b1
Description:
Soil Heat Flow #5 was large positive for these two periods, for
an unknown reason.
Measurements:sgp30ebbrE26.b1:
  • surface_soil_heat_flux_avg
  • latent_heat_flux
  • surface_soil_heat_flux_5
  • soil_heat_flow_5
  • corr_soil_heat_flow_5
  • sensible_heat_flux

sgp15ebbrE26.b1:
  • soil_heat_flow_5_mv


Back To Table of Contents

DQRID : D030728.5
Start DateStart TimeEnd DateEnd Time
06/25/2003163006/25/20031630
Subject:
SGP/EBBR/E27  - Soil Heat Flow #1 Large
DataStreams:sgp15ebbrE27.b1, sgp30ebbrE27.b1
Description:
Soil Heat Flow #1 was large for this period, for
an unknown reason.
Measurements:sgp15ebbrE27.b1:
  • soil_heat_flow_1_mv

sgp30ebbrE27.b1:
  • corr_soil_heat_flow_1
  • latent_heat_flux
  • surface_soil_heat_flux_1
  • soil_heat_flow_1
  • sensible_heat_flux
  • surface_soil_heat_flux_avg


Back To Table of Contents

DQRID : D030728.6
Start DateStart TimeEnd DateEnd Time
07/09/2003170007/09/20031700
Subject:
SGP/EBBR/E27  - Incorrect Data From Logger Restart
DataStreams:sgp30ebbrE27.b1
Description:
Some 30 minute was zero or incorrect after restart of the CR10.

This is a common occurrence when sensor replacements are made or power
outages occur.
Measurements:sgp30ebbrE27.b1:
  • latent_heat_flux
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_3
  • surface_soil_heat_flux_4
  • surface_soil_heat_flux_5
  • home_signal_15
  • surface_soil_heat_flux_avg
  • surface_soil_heat_flux_1
  • energy_storage_change_3
  • energy_storage_change_4
  • energy_storage_change_5
  • sensible_heat_flux
  • energy_storage_change_1
  • energy_storage_change_2


Back To Table of Contents

DQRID : D030729.4
Start DateStart TimeEnd DateEnd Time
07/16/2003033007/23/20031830
07/24/2003150008/06/20031730
Subject:
SGP/EBBR/E22 - AEM Hung Inbetween Home Positions
DataStreams:sgp15ebbrE22.b1, sgp30ebbrE22.b1, sgp5ebbrE22.b1
Description:
The AEM was hung inbetween home positions.
Measurements:sgp30ebbrE22.b1:
  • bowen_ratio
  • temp_trh_top
  • vapor_pressure_bottom
  • vapor_pressure_top
  • sensible_heat_flux
  • temp_air_top
  • temp_air_bottom
  • latent_heat_flux
  • temp_trh_bottom
  • rh_bottom_fraction
  • rh_top_fraction

sgp5ebbrE22.b1:
  • vapor_pressure_bottom
  • vapor_pressure_top
  • rh_bottom_fraction
  • temp_trh_top
  • temp_air_top
  • rh_top_fraction
  • temp_trh_bottom
  • temp_air_bottom

sgp15ebbrE22.b1:
  • temp_trh_right_rr
  • rh_left_mv
  • temp_trh_left_rr
  • rh_right_mv
  • temp_air_left
  • temp_air_right


Back To Table of Contents

DQRID : D030916.2
Start DateStart TimeEnd DateEnd Time
08/16/2003174509/17/20031900
Subject:
SGP/EBBR/E22 - AEM Home Signals Too High
DataStreams:sgp30ebbrE22.b1, sgp5ebbrE22.b1
Description:
The AEM home signals were too large at times during the indicated period;
it has been determined by the vendor that this is usually caused by electrical noise in 
the vicinity. When the 30 minute data shows a home 30 signal of 35 or more, the bowen 
ratio, and sensible and latent heat flux 
measurements are incorrect 

Removing the jumper between 4L and AG on the CR10 and adding a jumper to Multiplexer 2, 
Set 6, between L1 and L2 fixed the problem.  The
vendor intends to make this modification to all EBBR systems as they return
for re-calibration.
Measurements:sgp30ebbrE22.b1:
  • vapor_pressure_top
  • bowen_ratio
  • sensible_heat_flux
  • temp_air_top
  • temp_trh_top
  • temp_air_bottom
  • latent_heat_flux
  • rh_bottom_fraction
  • temp_trh_bottom
  • rh_top_fraction
  • vapor_pressure_bottom

sgp5ebbrE22.b1:
  • vapor_pressure_top
  • rh_bottom_fraction
  • temp_trh_top
  • vapor_pressure_bottom
  • temp_air_top
  • rh_top_fraction
  • temp_trh_bottom
  • temp_air_bottom


Back To Table of Contents

DQRID : D030919.11
Start DateStart TimeEnd DateEnd Time
08/21/2003160008/21/20031600
Subject:
SGP/EBBR/E26  - Soil Storage Incorrect; Surface Fluxes Incorrect
DataStreams:sgp30ebbrE26.b1
Description:
The half hour after restart of the CR10 datalogger, the soil temperatures for the 
beginning of the period are missing.  Therefore the soil energy storage and surface flux values 
are also incorrect.
Measurements:sgp30ebbrE26.b1:
  • surface_soil_heat_flux_avg
  • energy_storage_change_1
  • energy_storage_change_2
  • latent_heat_flux
  • energy_storage_change_3
  • energy_storage_change_4
  • surface_soil_heat_flux_2
  • energy_storage_change_5
  • surface_soil_heat_flux_1
  • sensible_heat_flux
  • surface_soil_heat_flux_5
  • surface_soil_heat_flux_3
  • surface_soil_heat_flux_4


Back To Table of Contents

DQRID : D030919.12
Start DateStart TimeEnd DateEnd Time
08/30/2003063009/03/20031700
Subject:
SGP/EBBR/E27  - Water in Net Radiometer; Surface Fluxes are Incorrect
DataStreams:sgp15ebbrE27.b1, sgp30ebbrE27.b1, sgp5ebbrE27.b1
Description:
The net radiometer top dome was punctured by migrating birds.  This alone does not cause 
incorrect net radiation measurements.  However, when it subsequently rains, water collects 
in the bottom dome, causing the net radiation measurements to be too large during the 
day and too small at night.
Measurements:sgp5ebbrE27.b1:
  • net_radiation

sgp15ebbrE27.b1:
  • net_radiation_mv

sgp30ebbrE27.b1:
  • latent_heat_flux
  • net_radiation
  • sensible_heat_flux


Back To Table of Contents

DQRID : D030919.13
Start DateStart TimeEnd DateEnd Time
08/20/2003160008/20/20031600
Subject:
SGP/EBBR/E27  - 15 and 30 Minute Data All Zeros
DataStreams:sgp15ebbrE27.b1, sgp30ebbrE27.b1
Description:
15 and 30 minute measurements were all zero after restarting the CR10 datalogger.
Measurements:sgp15ebbrE27.b1:
  • wdir_vec_mean_mv
  • soil_heat_flow_2_mv
  • soil_heat_flow_4_mv
  • atmos_pressure_mv
  • soil_moisture_3_rr
  • soil_moisture_1_rr
  • battery_voltage
  • soil_temp_5_rr
  • soil_heat_flow_1_mv
  • wspd_arith_mean
  • temp_air_left
  • soil_temp_3_rr
  • home_signal
  • soil_moisture_5_rr
  • soil_moisture_4_rr
  • temp_reference_rr
  • soil_heat_flow_3_mv
  • soil_moisture_2_rr
  • soil_heat_flow_5_mv
  • temp_trh_right_rr
  • rh_right_mv
  • soil_temp_4_rr
  • soil_temp_1_rr
  • net_radiation_mv
  • soil_temp_2_rr
  • temp_air_right
  • rh_left_mv
  • temp_trh_left_rr

sgp30ebbrE27.b1:
  • latent_heat_flux
  • surface_soil_heat_flux_2
  • soil_heat_flow_1
  • surface_soil_heat_flux_3
  • soil_heat_flow_2
  • surface_soil_heat_flux_4
  • surface_soil_heat_flux_5
  • soil_heat_flow_5
  • soil_heat_flow_3
  • soil_heat_flow_4
  • net_radiation
  • energy_storage_change_3
  • energy_storage_change_4
  • energy_storage_change_5
  • energy_storage_change_1
  • energy_storage_change_2
  • home_signal_30
  • rh_bottom_fraction
  • soil_moisture_1
  • rh_top_fraction
  • soil_temp_1
  • surface_soil_heat_flux_1
  • soil_temp_4
  • soil_moisture_2
  • soil_temp_5
  • soil_moisture_3
  • soil_temp_2
  • soil_moisture_4
  • soil_temp_3
  • soil_moisture_5
  • vapor_pressure_top
  • corr_soil_heat_flow_1
  • soil_heat_capacity_5
  • soil_heat_capacity_3
  • soil_heat_capacity_4
  • temp_air_top
  • sensible_heat_flux
  • Barometric Pressure(atmos_pressure)
  • wdir_vec_mean
  • wdir_vec_std
  • wspd_arith_mean
  • home_signal_15
  • surface_soil_heat_flux_avg
  • temp_air_bottom
  • temp_trh_bottom
  • temp_reference
  • temp_trh_top
  • soil_heat_capacity_2
  • soil_heat_capacity_1
  • wspd_vec_mean
  • vapor_pressure_bottom
  • corr_soil_heat_flow_2
  • bowen_ratio
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_4
  • corr_soil_heat_flow_5


Back To Table of Contents

DQRID : D030922.7
Start DateStart TimeEnd DateEnd Time
10/15/2003103011/17/20030630
Subject:
SGP/EBBR/E27 - Right Air Temperature Spiked Offscale
DataStreams:sgp15ebbrE27.b1, sgp30ebbrE27.b1, sgp5ebbrE27.b1
Description:
The right air temperature was going offscale at times.
This problem seemed to end without Site Ops. intervention.
Measurements:sgp5ebbrE27.b1:
  • temp_air_top
  • temp_air_bottom

sgp15ebbrE27.b1:
  • temp_air_right

sgp30ebbrE27.b1:
  • latent_heat_flux
  • temp_air_top
  • sensible_heat_flux
  • bowen_ratio
  • temp_air_bottom


Back To Table of Contents

DQRID : D031021.3
Start DateStart TimeEnd DateEnd Time
10/29/2003170010/29/20031930
Subject:
SGP/EBBR/E27 - Missing data during system update
DataStreams:sgp15ebbrE27.b1, sgp30ebbrE27.b1, sgp5ebbrE27.b1
Description:
Some soil parameters were slightly incorrect since EBBR.E27 was 
                 installed in May 2003.  While the coefficients were being updated,
                 data collection was suspended resulting in missing data for the 
                 specified period.
                    No significant effects (1% or less) on the surface heat flux data 
                 would have occurred from using the slightly incorrect coefficients. 
                 Therefore, flagging of the surface flux data from the time of 
                 installation of E27 is unwarranted.
Measurements:sgp5ebbrE27.b1:
  • rh_top_fraction
  • base time(base_time)
  • temp_reference
  • vapor_pressure_bottom
  • lon(lon)
  • temp_trh_bottom
  • temp_air_bottom
  • home_signal
  • time(time)
  • wspd_vec_mean
  • lat(lat)
  • wdir_vec_std
  • wspd_arith_mean
  • rh_bottom_fraction
  • temp_air_top
  • wdir_vec_mean
  • net_radiation
  • Barometric Pressure(atmos_pressure)
  • Dummy altitude for Zeb(alt)
  • Time offset of tweaks from base_time(time_offset)
  • vapor_pressure_top
  • temp_trh_top

sgp15ebbrE27.b1:
  • wdir_vec_mean_mv
  • soil_heat_flow_4_mv
  • lon(lon)
  • soil_moisture_1_rr
  • soil_moisture_3_rr
  • battery_voltage
  • Time offset of tweaks from base_time(time_offset)
  • soil_temp_5_rr
  • wspd_arith_mean
  • Dummy altitude for Zeb(alt)
  • temp_air_left
  • soil_moisture_5_rr
  • soil_moisture_4_rr
  • temp_reference_rr
  • soil_moisture_2_rr
  • soil_temp_1_rr
  • net_radiation_mv
  • lat(lat)
  • temp_air_right
  • temp_trh_left_rr
  • soil_heat_flow_2_mv
  • atmos_pressure_mv
  • soil_heat_flow_1_mv
  • soil_temp_3_rr
  • home_signal
  • soil_heat_flow_3_mv
  • temp_trh_right_rr
  • soil_heat_flow_5_mv
  • rh_right_mv
  • base time(base_time)
  • soil_temp_4_rr
  • soil_temp_2_rr
  • rh_left_mv

sgp30ebbrE27.b1:
  • surface_soil_heat_flux_2
  • soil_heat_flow_1
  • surface_soil_heat_flux_3
  • soil_heat_flow_2
  • surface_soil_heat_flux_4
  • surface_soil_heat_flux_5
  • soil_heat_flow_5
  • soil_heat_flow_3
  • soil_heat_flow_4
  • energy_storage_change_3
  • energy_storage_change_4
  • energy_storage_change_5
  • energy_storage_change_1
  • energy_storage_change_2
  • rh_bottom_fraction
  • rh_top_fraction
  • surface_soil_heat_flux_1
  • corr_soil_heat_flow_1
  • Time offset of tweaks from base_time(time_offset)
  • temp_air_top
  • sensible_heat_flux
  • lon(lon)
  • Barometric Pressure(atmos_pressure)
  • wdir_vec_mean
  • wspd_arith_mean
  • temp_air_bottom
  • temp_trh_bottom
  • temp_trh_top
  • wspd_vec_mean
  • vapor_pressure_bottom
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_4
  • corr_soil_heat_flow_5
  • latent_heat_flux
  • net_radiation
  • home_signal_30
  • soil_moisture_1
  • soil_temp_1
  • soil_temp_4
  • soil_moisture_2
  • soil_temp_5
  • soil_moisture_3
  • soil_temp_2
  • soil_moisture_4
  • soil_temp_3
  • soil_moisture_5
  • base time(base_time)
  • vapor_pressure_top
  • soil_heat_capacity_5
  • soil_heat_capacity_3
  • soil_heat_capacity_4
  • lat(lat)
  • Dummy altitude for Zeb(alt)
  • wdir_vec_std
  • home_signal_15
  • surface_soil_heat_flux_avg
  • temp_reference
  • soil_heat_capacity_2
  • soil_heat_capacity_1
  • bowen_ratio


Back To Table of Contents

DQRID : D031031.8
Start DateStart TimeEnd DateEnd Time
09/29/2003180010/01/20031630
Subject:
SGP/EBBR/E22  - Water in Net Radiometer, Surface Fluxes Incorrect
DataStreams:sgp15ebbrE22.b1, sgp30ebbrE22.b1, sgp5ebbrE22.b1
Description:
The net radiometer top dome was punctured by migrating birds.  This alone does not cause 
incorrect net radiation measurements.  However, when it subsequently rains, water collects 
in the bottom dome, causing the net radiation measurements to be too large during the 
day and too small at night.
Measurements:sgp30ebbrE22.b1:
  • latent_heat_flux
  • sensible_heat_flux
  • net_radiation

sgp5ebbrE22.b1:
  • net_radiation

sgp15ebbrE22.b1:
  • net_radiation_mv


Back To Table of Contents

DQRID : D031103.1
Start DateStart TimeEnd DateEnd Time
10/30/2003154511/13/20031545
Subject:
SGP/EBBR/E26 - AEM Home Signals Incorrect, Surface Fluxes Incorrect
DataStreams:sgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
Description:
During a preventative maintenance visit to perform the 6-month
calibrations, the home15 and home30 outputs began reading the
same as one another.  A fuse replacement and lubrication of the 
AEM sprockets on 11/13 corrected the problem.

During the interval specified, the home15, home30, and sensible
and latent heat fluxes are incorrect.
Measurements:sgp30ebbrE26.b1:
  • temp_air_bottom
  • temp_air_top
  • temp_trh_bottom
  • temp_trh_top
  • bowen_ratio
  • rh_top_fraction
  • home_signal_30
  • rh_bottom_fraction
  • home_signal_15
  • latent_heat_flux
  • vapor_pressure_top
  • sensible_heat_flux
  • vapor_pressure_bottom

sgp15ebbrE26.b1:
  • rh_left_mv
  • temp_trh_left_rr
  • temp_air_left
  • temp_trh_right_rr
  • rh_right_mv
  • temp_air_right

sgp5ebbrE26.b1:
  • home_signal
  • temp_trh_top
  • temp_trh_bottom
  • temp_air_top
  • temp_air_bottom
  • rh_top_fraction
  • rh_bottom_fraction
  • vapor_pressure_top
  • vapor_pressure_bottom


Back To Table of Contents

DQRID : D031117.3
Start DateStart TimeEnd DateEnd Time
09/06/2003120010/11/20030730
Subject:
SGP/EBBR/E27 - Right Air Temperature Spiked Offscale
DataStreams:sgp15ebbrE27.b1, sgp30ebbrE27.b1, sgp5ebbrE27.b1
Description:
The right air temperature was going offscale at times.
Measurements:sgp5ebbrE27.b1:
  • temp_air_top
  • temp_air_bottom

sgp15ebbrE27.b1:
  • temp_air_right

sgp30ebbrE27.b1:
  • latent_heat_flux
  • temp_air_top
  • sensible_heat_flux
  • bowen_ratio
  • temp_air_bottom


Back To Table of Contents

DQRID : D031204.20
Start DateStart TimeEnd DateEnd Time
10/15/2003190010/15/20031930
Subject:
SGP/EBBR/E22 - 6 Month Checks
DataStreams:sgp15ebbrE22.b1, sgp30ebbrE22.b1, sgp5ebbrE22.b1
Description:
Many measurements were incorrect while the AEM was positioned with both aspirators at the 
same height for comparison checks.
Measurements:sgp30ebbrE22.b1:
  • bowen_ratio
  • temp_trh_top
  • vapor_pressure_bottom
  • vapor_pressure_top
  • sensible_heat_flux
  • temp_air_top
  • temp_air_bottom
  • latent_heat_flux
  • temp_trh_bottom
  • rh_bottom_fraction
  • rh_top_fraction

sgp5ebbrE22.b1:
  • vapor_pressure_bottom
  • vapor_pressure_top
  • rh_bottom_fraction
  • temp_trh_top
  • temp_air_top
  • rh_top_fraction
  • temp_trh_bottom
  • temp_air_bottom

sgp15ebbrE22.b1:
  • temp_trh_right_rr
  • rh_left_mv
  • temp_trh_left_rr
  • rh_right_mv
  • temp_air_left
  • temp_air_right


Back To Table of Contents

DQRID : D031204.21
Start DateStart TimeEnd DateEnd Time
10/30/2003153510/30/20031615
Subject:
SGP/EBBR/E26 - 6 Month Checks
DataStreams:sgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
Description:
Many measurements were incorrect while the AEM was positioned with both aspirators at the 
same height for comparison checks.
Measurements:sgp30ebbrE26.b1:
  • temp_air_bottom
  • temp_air_top
  • temp_trh_bottom
  • temp_trh_top
  • rh_top_fraction
  • bowen_ratio
  • rh_bottom_fraction
  • latent_heat_flux
  • sensible_heat_flux
  • vapor_pressure_top
  • vapor_pressure_bottom

sgp15ebbrE26.b1:
  • rh_left_mv
  • temp_trh_left_rr
  • temp_air_left
  • temp_trh_right_rr
  • rh_right_mv
  • temp_air_right

sgp5ebbrE26.b1:
  • temp_trh_top
  • temp_trh_bottom
  • temp_air_top
  • temp_air_bottom
  • rh_top_fraction
  • rh_bottom_fraction
  • vapor_pressure_top
  • vapor_pressure_bottom


Back To Table of Contents

DQRID : D031204.22
Start DateStart TimeEnd DateEnd Time
10/29/2003183010/29/20031945
Subject:
SGP/EBBR/E27 - 6 Month Checks
DataStreams:sgp15ebbrE27.b1, sgp30ebbrE27.b1, sgp5ebbrE27.b1
Description:
Many measurements were incorrect while the AEM was positioned with both aspirators at the 
same height for comparison checks.
Measurements:sgp5ebbrE27.b1:
  • temp_trh_bottom
  • temp_air_bottom
  • rh_top_fraction
  • temp_air_top
  • rh_bottom_fraction
  • vapor_pressure_top
  • temp_trh_top
  • vapor_pressure_bottom

sgp15ebbrE27.b1:
  • temp_trh_right_rr
  • rh_right_mv
  • temp_air_right
  • temp_air_left
  • rh_left_mv
  • temp_trh_left_rr

sgp30ebbrE27.b1:
  • latent_heat_flux
  • temp_air_top
  • sensible_heat_flux
  • rh_bottom_fraction
  • rh_top_fraction
  • temp_air_bottom
  • temp_trh_bottom
  • temp_trh_top
  • vapor_pressure_top
  • bowen_ratio
  • vapor_pressure_bottom


Back To Table of Contents

DQRID : D031210.1
Start DateStart TimeEnd DateEnd Time
09/12/2003170010/12/20032359
Subject:
SGP/EBBR/E27 - Reprocess: Soil Heat Flow #5 Offscale, Surface Fluxes Incorrect
DataStreams:sgp15ebbrE27.b1, sgp30ebbrE27.b1
Description:
Soil Heat Flow #5 went offscale at times.

Latent and Sensible Heat Fluxes were incorrect when this occurred.
Measurements:sgp15ebbrE27.b1:
  • soil_heat_flow_5_mv

sgp30ebbrE27.b1:
  • latent_heat_flux
  • surface_soil_heat_flux_5
  • sensible_heat_flux
  • soil_heat_flow_5
  • surface_soil_heat_flux_avg
  • corr_soil_heat_flow_5


Back To Table of Contents

DQRID : D031211.3
Start DateStart TimeEnd DateEnd Time
10/13/2003000009/29/20041845
Subject:
SGP/EBBR/E26 - Spark Gap Bad, Pressure Incorrect
DataStreams:sgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
Description:
In a trip to E26, I found that a bad spark gap through which the barometer was powered was 
causing pressure measurements to be incorrect.  The pressure readings oscillated with 
the voltage of the EBBR battery.  During daytime the voltage and thus the pressure would 
increase and vice versa during dark hours.

Apparently only the positive side of the power supply was properly connected through the 
spark gap and thus the voltage received by the pressure sensor was lower than required to 
power it properly.  Under this condition the perssure measurement varies with voltage 
level.  The pressure measurements therefore had a diurnal signature and usually were 
incorrect.  

The decreased pressure during most times would cause latent heat flux to be slightly 
overestimated and sensible heat flux to be slightly underestimated.
Measurements:sgp30ebbrE26.b1:
  • bowen_ratio
  • latent_heat_flux
  • Barometric Pressure(atmos_pressure)
  • sensible_heat_flux

sgp15ebbrE26.b1:
  • atmos_pressure_mv

sgp5ebbrE26.b1:
  • Barometric Pressure(atmos_pressure)


Back To Table of Contents

DQRID : D031222.21
Start DateStart TimeEnd DateEnd Time
12/12/2003181012/13/20032100
Subject:
SGP/EBBR/E22  - Wind Speed Sensor Frozen By Ice Storm
DataStreams:sgp15ebbrE22.b1, sgp30ebbrE22.b1, sgp5ebbrE22.b1
Description:
The wind speed sensor was frozen stopped by ice from a storm.  The wind speed 
and residual wind speed measurements are incorrect.
Measurements:sgp30ebbrE22.b1:
  • wspd_vec_mean
  • wspd_arith_mean

sgp5ebbrE22.b1:
  • wspd_vec_mean
  • wspd_arith_mean

sgp15ebbrE22.b1:
  • wspd_arith_mean


Back To Table of Contents

DQRID : D031222.22
Start DateStart TimeEnd DateEnd Time
12/13/2003234512/14/20031520
Subject:
SGP/EBBR/E22 - Wind Direction Sensor Frozen By Ice Storm
DataStreams:sgp15ebbrE22.b1, sgp30ebbrE22.b1, sgp5ebbrE22.b1
Description:
The wind direction sensor was frozen stopped by ice from a storm.  
The wind direction, sigma_wd, and residual wind speed measurements 
are incorrect.
Measurements:sgp30ebbrE22.b1:
  • wspd_vec_mean
  • wdir_vec_mean
  • wdir_vec_std

sgp5ebbrE22.b1:
  • wdir_vec_std
  • wdir_vec_mean
  • wspd_vec_mean

sgp15ebbrE22.b1:
  • wdir_vec_mean_mv


Back To Table of Contents

DQRID : D031222.24
Start DateStart TimeEnd DateEnd Time
12/12/2003193512/14/20031615
Subject:
SGP/EBBR/E26  - Wind Speed Sensor Frozen By Ice Storm
DataStreams:sgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
Description:
The wind speed sensor was frozen stopped by ice from a storm.  The wind speed 
and residual wind speed measurements are incorrect.
Measurements:sgp30ebbrE26.b1:
  • wspd_arith_mean
  • wspd_vec_mean

sgp15ebbrE26.b1:
  • wspd_arith_mean

sgp5ebbrE26.b1:
  • wspd_arith_mean
  • wspd_vec_mean


Back To Table of Contents

DQRID : D031222.25
Start DateStart TimeEnd DateEnd Time
12/12/2003214012/14/20031530
Subject:
SGP/EBBR/E26  - Wind Direction Sensor Frozen By Ice Storm
DataStreams:sgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
Description:
The wind direction sensor was frozen stopped by ice from a storm.  
The wind direction, sigma_wd, and residual wind speed measurements 
are incorrect.
Measurements:sgp30ebbrE26.b1:
  • wdir_vec_mean
  • wdir_vec_std
  • wspd_vec_mean

sgp15ebbrE26.b1:
  • wdir_vec_mean_mv

sgp5ebbrE26.b1:
  • wdir_vec_mean
  • wdir_vec_std
  • wspd_vec_mean


Back To Table of Contents

DQRID : D031222.26
Start DateStart TimeEnd DateEnd Time
12/06/2003090012/06/20030900
Subject:
SGP/EBBR/E27 - Soil Temperature #3 Spike in Data
DataStreams:sgp15ebbrE27.b1, sgp30ebbrE27.b1
Description:
The soil temperature #3 spiked to zero and was therefore incorrect.
Measurements:sgp15ebbrE27.b1:
  • soil_temp_3_rr

sgp30ebbrE27.b1:
  • latent_heat_flux
  • soil_temp_3
  • energy_storage_change_3
  • surface_soil_heat_flux_3
  • sensible_heat_flux
  • surface_soil_heat_flux_avg


Back To Table of Contents

DQRID : D040303.2
Start DateStart TimeEnd DateEnd Time
12/13/2003000003/17/20041835
Subject:
SGP/EBBR/E22 - Wind Speed Sensor Bearings Worn
DataStreams:sgp15ebbrE22.b1, sgp30ebbrE22.b1, sgp5ebbrE22.b1
Description:
Wind speed was too low and/or often at or near zero due to
               worn bearings in the wind speed sensor.  Sensor was replaced
               3/17/04.
Measurements:sgp30ebbrE22.b1:
  • wspd_vec_mean
  • wspd_arith_mean

sgp5ebbrE22.b1:
  • wspd_vec_mean
  • wspd_arith_mean

sgp15ebbrE22.b1:
  • wspd_arith_mean


Back To Table of Contents

DQRID : D040304.21
Start DateStart TimeEnd DateEnd Time
01/24/2004234501/25/20040135
02/01/2004192002/02/20041740
02/03/2004035002/03/20041440
02/05/2004092502/05/20041615
Subject:
SGP/EBBR/E22  - Wind Speed Frozen Stopped By Ice
DataStreams:sgp15ebbrE22.b1, sgp30ebbrE22.b1, sgp5ebbrE22.b1
Description:
An ice storm froze the wind speed sensor to a stopped condition.

The wind speed and residual wind speed measurements are incorrect.

This sensor failure does not affect the sensible and latent heat fluxes.
Measurements:sgp30ebbrE22.b1:
  • wspd_vec_mean
  • wspd_arith_mean

sgp5ebbrE22.b1:
  • wspd_vec_mean
  • wspd_arith_mean

sgp15ebbrE22.b1:
  • wspd_arith_mean


Back To Table of Contents

DQRID : D040304.22
Start DateStart TimeEnd DateEnd Time
02/05/2004112002/05/20041500
Subject:
SGP/EBBR/E22  - Wind Direction Frozen Stopped By Ice
DataStreams:sgp30ebbrE22.b1, sgp5ebbrE22.b1
Description:
The wind direction sensor was frozen stopped by ice from a storm.  
The wind direction, sigma_wd, and residual wind speed measurements 
are incorrect.
Measurements:sgp30ebbrE22.b1:
  • wspd_vec_mean
  • wdir_vec_mean
  • wdir_vec_std

sgp5ebbrE22.b1:
  • wdir_vec_std
  • wdir_vec_mean
  • wspd_vec_mean


Back To Table of Contents

DQRID : D040304.25
Start DateStart TimeEnd DateEnd Time
02/02/2004070502/02/20041800
02/05/2004020502/05/20040600
Subject:
SGP/EBBR/E27  - Wind Speed Frozen Stopped By Ice
DataStreams:sgp15ebbrE27.b1, sgp30ebbrE27.b1, sgp5ebbrE27.b1
Description:
An ice storm froze the wind speed sensor to a stopped condition.

The wind speed and residual wind speed measurements are incorrect.

This sensor failure does not affect the sensible and latent heat fluxes.
Measurements:sgp5ebbrE27.b1:
  • wspd_arith_mean
  • wspd_vec_mean

sgp15ebbrE27.b1:
  • wspd_arith_mean

sgp30ebbrE27.b1:
  • wspd_arith_mean
  • wspd_vec_mean


Back To Table of Contents

DQRID : D040304.28
Start DateStart TimeEnd DateEnd Time
02/02/2004020002/02/20041620
Subject:
SGP/EBBR/E26  - Wind Speed Frozen Stopped By Ice
DataStreams:sgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
Description:
An ice storm froze the wind speed sensor to a stopped condition.

The wind speed and residual wind speed measurements are incorrect.

This sensor failure does not affect the sensible and latent heat fluxes.
Measurements:sgp30ebbrE26.b1:
  • wspd_arith_mean
  • wspd_vec_mean

sgp15ebbrE26.b1:
  • wspd_arith_mean

sgp5ebbrE26.b1:
  • wspd_arith_mean
  • wspd_vec_mean


Back To Table of Contents

DQRID : D040304.29
Start DateStart TimeEnd DateEnd Time
02/02/2004041002/02/20041530
Subject:
SGP/EBBR/E26  - Wind Direction Frozen Stopped By Ice
DataStreams:sgp30ebbrE26.b1, sgp5ebbrE26.b1
Description:
The wind direction sensor was frozen stopped by ice from a storm.  
The wind direction, sigma_wd, and residual wind speed measurements 
are incorrect.
Measurements:sgp30ebbrE26.b1:
  • wdir_vec_mean
  • wdir_vec_std
  • wspd_vec_mean

sgp5ebbrE26.b1:
  • wdir_vec_mean
  • wdir_vec_std
  • wspd_vec_mean


Back To Table of Contents

DQRID : D040318.13
Start DateStart TimeEnd DateEnd Time
01/25/2004060005/12/20041930
Subject:
SGP/EBBR/E27 - Soil Moisture #5 Insensitive
DataStreams:sgp30ebbrE27.b1
Description:
Soil moisture sensor #5 was insensitive and put out a value of around 30%.

Sensible and latent heat fluxes were not significantly affected by this
small error.
Measurements:sgp30ebbrE27.b1:
  • soil_heat_capacity_5
  • soil_moisture_5
  • energy_storage_change_5
  • surface_soil_heat_flux_5
  • corr_soil_heat_flow_5


Back To Table of Contents

DQRID : D040507.3
Start DateStart TimeEnd DateEnd Time
03/01/2004000003/31/20042355
Subject:
SGP/EBBR/E27  - Right Air Temperature Incorrect
DataStreams:sgp15ebbrE27.b1, sgp30ebbrE27.b1, sgp5ebbrE27.b1
Description:
The right air temperature, and therefore top and bottom air temperatures
were offscale or incorrect on occasion.  Bowen ratio, sensible heat flux, and latent heat 
flux were also incorrect during those times.

Inspection of the data is required to detect the incorrect periods.
Measurements:sgp5ebbrE27.b1:
  • temp_air_top
  • temp_air_bottom

sgp15ebbrE27.b1:
  • temp_air_right

sgp30ebbrE27.b1:
  • latent_heat_flux
  • temp_air_top
  • sensible_heat_flux
  • bowen_ratio
  • temp_air_bottom


Back To Table of Contents

DQRID : D040706.2
Start DateStart TimeEnd DateEnd Time
06/22/2004040006/23/20041650
Subject:
SGP/EBBR/E22 - Net Radiation Incorrect
DataStreams:sgp30ebbrE22.b1, sgp5ebbrE22.b1
Description:
Rain filled the bottom of the net radiometer with water, resulting
in very high net radiations.  Net radiation is incorrect during this period,
also causing sensible and latent heat fluxes to be incorrect.
Measurements:sgp30ebbrE22.b1:
  • latent_heat_flux
  • sensible_heat_flux
  • net_radiation

sgp5ebbrE22.b1:
  • net_radiation


Back To Table of Contents

DQRID : D040706.3
Start DateStart TimeEnd DateEnd Time
06/10/2004060007/21/20041725
Subject:
SGP/EBBR/E27 - Loose Tair Left Connections
DataStreams:sgp15ebbrE27.b1, sgp30ebbrE27.b1, sgp5ebbrE27.b1
Description:
Tair left dropped out at times. When this occurred, the sensible and latent heat fluxes 
are incorrect.

Tightening of the electronic connections to the datalogging equipment
appears to have solved the problem.
Measurements:sgp5ebbrE27.b1:
  • temp_air_top
  • temp_air_bottom

sgp15ebbrE27.b1:
  • temp_air_left

sgp30ebbrE27.b1:
  • latent_heat_flux
  • temp_air_top
  • sensible_heat_flux
  • bowen_ratio
  • temp_air_bottom


Back To Table of Contents

DQRID : D040723.3
Start DateStart TimeEnd DateEnd Time
07/01/2004133007/07/20041900
Subject:
SGP/EBBR/E22 - Water In Net Radiometer
DataStreams:sgp30ebbrE22.b1, sgp5ebbrE22.b1
Description:
Water entered the Net Radiometer through a cracked upper dome, causing the
net radiation values to be too large.  As a result, latent and sensible heat flux values 
are also incorrect.
Measurements:sgp30ebbrE22.b1:
  • latent_heat_flux
  • sensible_heat_flux
  • net_radiation

sgp5ebbrE22.b1:
  • net_radiation


Back To Table of Contents

DQRID : D040813.2
Start DateStart TimeEnd DateEnd Time
08/03/2004030009/15/20042000
09/24/2004070009/29/20041800
Subject:
SGP/EBBR/E20 - AEM Failure
DataStreams:sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1
Description:
The AEM hung inbetween positions; home signals were zero.

The AEM fuse kept blowing, most likely because of worn
rails or sleeves.  This condition may reoccur.
Measurements:sgp5ebbrE20.b1:
  • temp_air_top
  • rh_bottom_fraction
  • temp_trh_top
  • temp_air_bottom
  • temp_trh_bottom
  • rh_top_fraction
  • vapor_pressure_bottom
  • vapor_pressure_top

sgp15ebbrE20.b1:
  • temp_air_left
  • temp_air_right

sgp30ebbrE20.b1:
  • temp_air_bottom
  • temp_trh_top
  • sensible_heat_flux
  • temp_air_top
  • latent_heat_flux
  • vapor_pressure_bottom
  • vapor_pressure_top
  • bowen_ratio
  • rh_bottom_fraction
  • rh_top_fraction
  • temp_trh_bottom


Back To Table of Contents

DQRID : D040813.5
Start DateStart TimeEnd DateEnd Time
07/30/2004160008/05/20041530
Subject:
SGP/EBBR/E26 - Soil Temperature #4 and Soil Heat Flow #4 Incorrect
DataStreams:sgp30ebbrE26.b1
Description:
The soil temperature and soil heat flow probes for set #4 was pulled 
partially out of the ground.  This caused soil temperature #4 to be too high and soil heat 
flow #4 to be too low.  The error is not so great as to cause a large error in the 
sensible and latent heat fluxes.
Measurements:sgp30ebbrE26.b1:
  • latent_heat_flux
  • energy_storage_change_4
  • corr_soil_heat_flow_4
  • soil_temp_4
  • surface_soil_heat_flux_4
  • soil_heat_capacity_4
  • sensible_heat_flux
  • soil_heat_flow_4


Back To Table of Contents

DQRID : D040915.7
Start DateStart TimeEnd DateEnd Time
09/08/2004213009/15/20041930
Subject:
SGP/EBBR/E20 - Soil Heat Flow #3 and Soil Temperature #3 Incorrect
DataStreams:sgp15ebbrE20.b1, sgp30ebbrE20.b1
Description:
Measurements:sgp15ebbrE20.b1:
  • soil_temp_3_rr
  • soil_heat_flow_3_mv

sgp30ebbrE20.b1:
  • energy_storage_change_3
  • corr_soil_heat_flow_3
  • soil_heat_flow_3
  • surface_soil_heat_flux_3
  • sensible_heat_flux
  • surface_soil_heat_flux_avg
  • soil_temp_3
  • latent_heat_flux


Back To Table of Contents

DQRID : D041006.3
Start DateStart TimeEnd DateEnd Time
09/15/2004193009/15/20042030
Subject:
SGP/EBBR/E20  - All Soil Measurements Incorrect
DataStreams:sgp15ebbrE20.b1, sgp30ebbrE20.b1
Description:
All soil measurements were incorrect during the replacement of soil heat flow #3 and soil 
temperature #3.
Measurements:sgp15ebbrE20.b1:
  • soil_temp_2_rr
  • soil_temp_3_rr
  • soil_heat_flow_3_mv
  • soil_moisture_1_rr
  • soil_heat_flow_4_mv
  • soil_moisture_4_rr
  • soil_heat_flow_5_mv
  • soil_temp_4_rr
  • soil_heat_flow_2_mv
  • soil_moisture_3_rr
  • soil_heat_flow_1_mv
  • soil_moisture_2_rr
  • soil_temp_1_rr
  • soil_temp_5_rr
  • soil_moisture_5_rr

sgp30ebbrE20.b1:
  • corr_soil_heat_flow_5
  • corr_soil_heat_flow_4
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_1
  • soil_moisture_4
  • soil_heat_capacity_2
  • soil_moisture_3
  • soil_heat_capacity_3
  • soil_heat_capacity_4
  • soil_moisture_5
  • soil_heat_capacity_5
  • soil_moisture_2
  • soil_moisture_1
  • soil_heat_capacity_1
  • surface_soil_heat_flux_5
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_1
  • surface_soil_heat_flux_4
  • surface_soil_heat_flux_3
  • sensible_heat_flux
  • latent_heat_flux
  • energy_storage_change_1
  • energy_storage_change_3
  • energy_storage_change_2
  • energy_storage_change_5
  • energy_storage_change_4
  • soil_temp_3
  • soil_temp_4
  • soil_temp_5
  • soil_temp_1
  • soil_temp_2
  • soil_heat_flow_1
  • soil_heat_flow_3
  • soil_heat_flow_2
  • soil_heat_flow_5
  • soil_heat_flow_4
  • surface_soil_heat_flux_avg


Back To Table of Contents

DQRID : D041222.1
Start DateStart TimeEnd DateEnd Time
03/21/2003153010/12/20032355
Subject:
SGP/EBBR/E26 - Spark Gap Bad, Pressure Incorrect
DataStreams:sgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
Description:
In a trip to E26, I found that a bad spark gap through which the barometer was powered was 
causing pressure measurements to be incorrect.  The pressure readings oscillated with 
the voltage of the EBBR battery.  During daytime the voltage and thus the pressure would 
increase and vice versa during dark hours.

Apparently only the positive side of the power supply was properly connected through the 
spark gap and thus the voltage received by the pressure sensor was lower than required to 
power it properly.  Under this condition the perssure measurement varies with voltage 
level.  The pressure measurements therefore had a diurnal signature and usually were 
incorrect.  

The decreased pressure during most times would cause latent heat flux to be slightly 
overestimated and sensible heat flux to be slightly underestimated.
Measurements:sgp30ebbrE26.b1:
  • bowen_ratio
  • latent_heat_flux
  • Barometric Pressure(atmos_pressure)
  • sensible_heat_flux

sgp15ebbrE26.b1:
  • atmos_pressure_mv

sgp5ebbrE26.b1:
  • Barometric Pressure(atmos_pressure)


Back To Table of Contents

DQRID : D041222.16
Start DateStart TimeEnd DateEnd Time
09/29/2004173009/29/20041800
Subject:
SGP/EBBR/E20 - 6 Month Checks
DataStreams:sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1
Description:
Many measurements were incorrect while the AEM was positioned with both aspirators at the 
same height for comparison checks.
Measurements:sgp5ebbrE20.b1:
  • temp_air_top
  • temp_trh_top
  • temp_trh_bottom
  • temp_air_bottom
  • rh_bottom_fraction
  • rh_top_fraction
  • vapor_pressure_bottom
  • vapor_pressure_top

sgp15ebbrE20.b1:
  • rh_left_mv
  • temp_air_left
  • rh_right_mv
  • temp_air_right
  • temp_trh_left_rr
  • temp_trh_right_rr

sgp30ebbrE20.b1:
  • sensible_heat_flux
  • temp_air_top
  • latent_heat_flux
  • vapor_pressure_bottom
  • rh_bottom_fraction
  • temp_air_bottom
  • temp_trh_top
  • vapor_pressure_top
  • bowen_ratio
  • rh_top_fraction
  • temp_trh_bottom


Back To Table of Contents

DQRID : D041222.17
Start DateStart TimeEnd DateEnd Time
10/27/2004170010/27/20041730
Subject:
SGP/EBBR/E22 - 6 Month Checks
DataStreams:sgp15ebbrE22.b1, sgp30ebbrE22.b1, sgp5ebbrE22.b1
Description:
Many measurements were incorrect while the AEM was positioned with both aspirators at the 
same height for comparison checks.
Measurements:sgp30ebbrE22.b1:
  • bowen_ratio
  • temp_trh_top
  • vapor_pressure_bottom
  • vapor_pressure_top
  • sensible_heat_flux
  • temp_air_top
  • temp_air_bottom
  • latent_heat_flux
  • temp_trh_bottom
  • rh_bottom_fraction
  • rh_top_fraction

sgp5ebbrE22.b1:
  • vapor_pressure_bottom
  • vapor_pressure_top
  • rh_bottom_fraction
  • temp_trh_top
  • temp_air_top
  • rh_top_fraction
  • temp_trh_bottom
  • temp_air_bottom

sgp15ebbrE22.b1:
  • temp_trh_right_rr
  • rh_left_mv
  • temp_trh_left_rr
  • rh_right_mv
  • temp_air_left
  • temp_air_right


Back To Table of Contents

DQRID : D041222.18
Start DateStart TimeEnd DateEnd Time
09/30/2004153009/30/20041600
Subject:
SGP/EBBR/E26 - 6 Month Checks
DataStreams:sgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
Description:
Many measurements were incorrect while the AEM was positioned with both aspirators at the 
same height for comparison checks.
Measurements:sgp30ebbrE26.b1:
  • temp_air_bottom
  • temp_air_top
  • temp_trh_bottom
  • temp_trh_top
  • rh_top_fraction
  • bowen_ratio
  • rh_bottom_fraction
  • latent_heat_flux
  • sensible_heat_flux
  • vapor_pressure_top
  • vapor_pressure_bottom

sgp15ebbrE26.b1:
  • rh_left_mv
  • temp_trh_left_rr
  • temp_air_left
  • temp_trh_right_rr
  • rh_right_mv
  • temp_air_right

sgp5ebbrE26.b1:
  • temp_trh_top
  • temp_trh_bottom
  • temp_air_top
  • temp_air_bottom
  • rh_top_fraction
  • rh_bottom_fraction
  • vapor_pressure_top
  • vapor_pressure_bottom


Back To Table of Contents

DQRID : D041222.19
Start DateStart TimeEnd DateEnd Time
09/29/2004200009/29/20042030
Subject:
SGP/EBBR/E27 - 6 Month Checks
DataStreams:sgp15ebbrE27.b1, sgp30ebbrE27.b1, sgp5ebbrE27.b1
Description:
Many measurements were incorrect while the AEM was positioned with both aspirators at the 
same height for comparison checks.
Measurements:sgp5ebbrE27.b1:
  • temp_trh_bottom
  • temp_air_bottom
  • rh_top_fraction
  • temp_air_top
  • rh_bottom_fraction
  • vapor_pressure_top
  • temp_trh_top
  • vapor_pressure_bottom

sgp15ebbrE27.b1:
  • temp_trh_right_rr
  • rh_right_mv
  • temp_air_right
  • temp_air_left
  • rh_left_mv
  • temp_trh_left_rr

sgp30ebbrE27.b1:
  • latent_heat_flux
  • temp_air_top
  • sensible_heat_flux
  • rh_bottom_fraction
  • rh_top_fraction
  • temp_air_bottom
  • temp_trh_bottom
  • temp_trh_top
  • vapor_pressure_top
  • bowen_ratio
  • vapor_pressure_bottom


Back To Table of Contents

DQRID : D041222.3
Start DateStart TimeEnd DateEnd Time
11/02/2004133003/02/20051930
Subject:
SGP/EBBR/E20 - Soil Moisture #4 and Soil Temperature #4 Incorrect
DataStreams:sgp15ebbrE20.b1, sgp30ebbrE20.b1
Description:
Failures of a multiplexer channel and a J-panel channel caused soil temperature #4 and 
soil moisture #4 to spike and drift at times.  Replacement of the failed equipment solved 
the problem.
Measurements:sgp15ebbrE20.b1:
  • soil_moisture_4_rr
  • soil_temp_4_rr

sgp30ebbrE20.b1:
  • soil_moisture_4
  • corr_soil_heat_flow_4
  • soil_heat_capacity_4
  • energy_storage_change_4
  • surface_soil_heat_flux_4
  • sensible_heat_flux
  • surface_soil_heat_flux_avg
  • soil_temp_4
  • latent_heat_flux


Back To Table of Contents

DQRID : D041222.4
Start DateStart TimeEnd DateEnd Time
10/27/2004193011/05/20040100
11/10/2004060011/24/20041500
Subject:
SGP/EBBR/E26 - Low Battery Voltage - Many Measurements Incorrect
DataStreams:sgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
Description:
During low battery voltage conditions (< 10.5 V especially) many measurements are 
incorrect.
Measurements:sgp30ebbrE26.b1:
  • wspd_vec_mean
  • rh_top_fraction
  • wspd_arith_mean
  • latent_heat_flux
  • vapor_pressure_top
  • vapor_pressure_bottom
  • corr_soil_heat_flow_4
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_1
  • temp_reference
  • corr_soil_heat_flow_5
  • wdir_vec_std
  • temp_air_top
  • surface_soil_heat_flux_5
  • soil_moisture_5
  • surface_soil_heat_flux_3
  • surface_soil_heat_flux_4
  • soil_moisture_1
  • soil_moisture_2
  • soil_moisture_3
  • soil_moisture_4
  • temp_trh_top
  • rh_bottom_fraction
  • home_signal_15
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_1
  • sensible_heat_flux
  • surface_soil_heat_flux_avg
  • net_radiation
  • soil_heat_capacity_5
  • soil_heat_capacity_4
  • soil_heat_capacity_2
  • soil_heat_capacity_3
  • bowen_ratio
  • home_signal_30
  • soil_heat_capacity_1
  • soil_temp_5
  • soil_temp_4
  • soil_heat_flow_3
  • soil_temp_3
  • soil_heat_flow_2
  • soil_temp_2
  • soil_heat_flow_1
  • soil_temp_1
  • soil_heat_flow_5
  • soil_heat_flow_4
  • temp_air_bottom
  • wdir_vec_mean
  • energy_storage_change_1
  • energy_storage_change_2
  • energy_storage_change_3
  • energy_storage_change_4
  • energy_storage_change_5
  • temp_trh_bottom
  • Barometric Pressure(atmos_pressure)

sgp15ebbrE26.b1:
  • wdir_vec_mean_mv
  • soil_heat_flow_4_mv
  • soil_moisture_4_rr
  • soil_heat_flow_3_mv
  • soil_temp_1_rr
  • soil_moisture_5_rr
  • temp_trh_right_rr
  • soil_heat_flow_2_mv
  • soil_temp_3_rr
  • soil_moisture_2_rr
  • soil_heat_flow_1_mv
  • soil_temp_4_rr
  • temp_trh_left_rr
  • temp_air_left
  • rh_right_mv
  • soil_moisture_3_rr
  • home_signal
  • soil_moisture_1_rr
  • temp_air_right
  • rh_left_mv
  • soil_temp_5_rr
  • soil_heat_flow_5_mv
  • temp_reference_rr
  • soil_temp_2_rr
  • wspd_arith_mean
  • atmos_pressure_mv
  • net_radiation_mv

sgp5ebbrE26.b1:
  • temp_trh_bottom
  • wspd_arith_mean
  • wdir_vec_std
  • rh_top_fraction
  • home_signal
  • Barometric Pressure(atmos_pressure)
  • rh_bottom_fraction
  • temp_reference
  • wdir_vec_mean
  • temp_trh_top
  • temp_air_top
  • wspd_vec_mean
  • temp_air_bottom
  • vapor_pressure_bottom
  • vapor_pressure_top
  • net_radiation


Back To Table of Contents

DQRID : D041222.5
Start DateStart TimeEnd DateEnd Time
10/29/2004110010/29/20041600
Subject:
SGP/EBBR/E26 - Most Measurements Incorrect
DataStreams:sgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
Description:
Most of the measurements became either too large or too small.
The cause is not known.
Measurements:sgp30ebbrE26.b1:
  • wspd_vec_mean
  • rh_top_fraction
  • wspd_arith_mean
  • latent_heat_flux
  • vapor_pressure_top
  • vapor_pressure_bottom
  • corr_soil_heat_flow_4
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_1
  • temp_reference
  • corr_soil_heat_flow_5
  • wdir_vec_std
  • temp_air_top
  • surface_soil_heat_flux_5
  • soil_moisture_5
  • surface_soil_heat_flux_3
  • surface_soil_heat_flux_4
  • soil_moisture_1
  • soil_moisture_2
  • soil_moisture_3
  • soil_moisture_4
  • temp_trh_top
  • rh_bottom_fraction
  • home_signal_15
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_1
  • sensible_heat_flux
  • surface_soil_heat_flux_avg
  • net_radiation
  • soil_heat_capacity_5
  • soil_heat_capacity_4
  • soil_heat_capacity_2
  • soil_heat_capacity_3
  • bowen_ratio
  • home_signal_30
  • soil_heat_capacity_1
  • soil_temp_5
  • soil_temp_4
  • soil_heat_flow_3
  • soil_temp_3
  • soil_heat_flow_2
  • soil_temp_2
  • soil_heat_flow_1
  • soil_temp_1
  • soil_heat_flow_5
  • soil_heat_flow_4
  • temp_air_bottom
  • wdir_vec_mean
  • energy_storage_change_1
  • energy_storage_change_2
  • energy_storage_change_3
  • energy_storage_change_4
  • energy_storage_change_5
  • temp_trh_bottom
  • Barometric Pressure(atmos_pressure)

sgp15ebbrE26.b1:
  • wdir_vec_mean_mv
  • soil_heat_flow_4_mv
  • soil_moisture_4_rr
  • soil_heat_flow_3_mv
  • soil_temp_1_rr
  • soil_moisture_5_rr
  • temp_trh_right_rr
  • soil_heat_flow_2_mv
  • soil_temp_3_rr
  • soil_moisture_2_rr
  • soil_heat_flow_1_mv
  • soil_temp_4_rr
  • temp_trh_left_rr
  • temp_air_left
  • rh_right_mv
  • soil_moisture_3_rr
  • home_signal
  • soil_moisture_1_rr
  • temp_air_right
  • rh_left_mv
  • soil_temp_5_rr
  • soil_heat_flow_5_mv
  • temp_reference_rr
  • soil_temp_2_rr
  • wspd_arith_mean
  • atmos_pressure_mv
  • net_radiation_mv

sgp5ebbrE26.b1:
  • temp_trh_bottom
  • wspd_arith_mean
  • wdir_vec_std
  • rh_top_fraction
  • home_signal
  • Barometric Pressure(atmos_pressure)
  • rh_bottom_fraction
  • temp_reference
  • wdir_vec_mean
  • temp_trh_top
  • temp_air_top
  • wspd_vec_mean
  • temp_air_bottom
  • vapor_pressure_bottom
  • vapor_pressure_top
  • net_radiation


Back To Table of Contents

DQRID : D041223.1
Start DateStart TimeEnd DateEnd Time
11/26/2004210012/08/20042100
Subject:
SGP/EBBR/E20 - Soil Heat Flow #4 Incorrect
DataStreams:sgp15ebbrE20.b1, sgp30ebbrE20.b1
Description:
Soil Heat Flow #4 was missing or offscale and therefore incorrect during the stated 
period.
Measurements:sgp15ebbrE20.b1:
  • soil_heat_flow_4_mv

sgp30ebbrE20.b1:
  • corr_soil_heat_flow_4
  • surface_soil_heat_flux_4
  • sensible_heat_flux
  • soil_heat_flow_4
  • surface_soil_heat_flux_avg
  • latent_heat_flux


Back To Table of Contents

DQRID : D050206.14
Start DateStart TimeEnd DateEnd Time
01/05/2005142001/07/20051650
Subject:
SGP/EBBR/E20  - Wind Speed Frozen Stopped By Ice Storm
DataStreams:sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1
Description:
An ice storm froze the wind speed sensor to a stopped condition.

The wind speed and residual wind speed measurements are incorrect.

This sensor failure does not affect the sensible and latent heat fluxes.
Measurements:sgp5ebbrE20.b1:
  • wspd_vec_mean
  • wspd_arith_mean

sgp15ebbrE20.b1:
  • wspd_arith_mean

sgp30ebbrE20.b1:
  • wspd_arith_mean
  • wspd_vec_mean


Back To Table of Contents

DQRID : D050206.15
Start DateStart TimeEnd DateEnd Time
01/05/2005084501/07/20051555
Subject:
SGP/EBBR/E22  - Wind Speed Frozen Stopped By Ice Storm
DataStreams:sgp15ebbrE22.b1, sgp30ebbrE22.b1, sgp5ebbrE22.b1
Description:
An ice storm froze the wind speed sensor to a stopped condition.

The wind speed and residual wind speed measurements are incorrect.

This sensor failure does not affect the sensible and latent heat fluxes.
Measurements:sgp30ebbrE22.b1:
  • wspd_vec_mean
  • wspd_arith_mean

sgp5ebbrE22.b1:
  • wspd_vec_mean
  • wspd_arith_mean

sgp15ebbrE22.b1:
  • wspd_arith_mean


Back To Table of Contents

DQRID : D050206.16
Start DateStart TimeEnd DateEnd Time
01/05/2005074501/07/20051530
Subject:
SGP/EBBR/E26  - Wind Speed Frozen Stopped By Ice Storm
DataStreams:sgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
Description:
An ice storm froze the wind speed sensor to a stopped condition.

The wind speed and residual wind speed measurements are incorrect.

This sensor failure does not affect the sensible and latent heat fluxes.
Measurements:sgp30ebbrE26.b1:
  • wspd_arith_mean
  • wspd_vec_mean

sgp15ebbrE26.b1:
  • wspd_arith_mean

sgp5ebbrE26.b1:
  • wspd_arith_mean
  • wspd_vec_mean


Back To Table of Contents

DQRID : D050206.17
Start DateStart TimeEnd DateEnd Time
01/05/2005155501/07/20051605
Subject:
SGP/EBBR/E27  - Wind Speed Frozen Stopped By Ice Storm
DataStreams:sgp15ebbrE27.b1, sgp30ebbrE27.b1, sgp5ebbrE27.b1
Description:
An ice storm froze the wind speed sensor to a stopped condition.

The wind speed and residual wind speed measurements are incorrect.

This sensor failure does not affect the sensible and latent heat fluxes.
Measurements:sgp5ebbrE27.b1:
  • wspd_arith_mean

sgp15ebbrE27.b1:
  • wspd_arith_mean

sgp30ebbrE27.b1:
  • wspd_arith_mean
  • wspd_vec_mean


Back To Table of Contents

DQRID : D050207.10
Start DateStart TimeEnd DateEnd Time
01/07/2005015001/07/20051425
Subject:
SGP/EBBR/E20  - Wind Direction Frozen Stopped By Ice Storm
DataStreams:sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1
Description:
The wind direction sensor was frozen stopped by ice from a storm.  
The wind direction, sigma_wd, and residual wind speed measurements 
are incorrect.
Measurements:sgp5ebbrE20.b1:
  • wspd_vec_mean
  • wdir_vec_mean
  • wdir_vec_std

sgp15ebbrE20.b1:
  • wdir_vec_mean_mv

sgp30ebbrE20.b1:
  • wdir_vec_mean
  • wdir_vec_std
  • wspd_vec_mean


Back To Table of Contents

DQRID : D050207.11
Start DateStart TimeEnd DateEnd Time
01/05/2005085501/06/20051940
Subject:
SGP/EBBR/E22  - Wind Direction Frozen Stopped By Ice Storm
DataStreams:sgp15ebbrE22.b1, sgp30ebbrE22.b1, sgp5ebbrE22.b1
Description:
The wind direction sensor was frozen stopped by ice from a storm.  
The wind direction, sigma_wd, and residual wind speed measurements 
are incorrect.
Measurements:sgp30ebbrE22.b1:
  • wspd_vec_mean
  • wdir_vec_mean
  • wdir_vec_std

sgp5ebbrE22.b1:
  • wdir_vec_std
  • wdir_vec_mean
  • wspd_vec_mean

sgp15ebbrE22.b1:
  • wdir_vec_mean_mv


Back To Table of Contents

DQRID : D050207.12
Start DateStart TimeEnd DateEnd Time
01/05/2005102001/06/20051730
Subject:
SGP/EBBR/E26  - Wind Direction Frozen Stopped By Ice Storm
DataStreams:sgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
Description:
The wind direction sensor was frozen stopped by ice from a storm.  
The wind direction, sigma_wd, and residual wind speed measurements 
are incorrect.
Measurements:sgp30ebbrE26.b1:
  • wdir_vec_mean
  • wdir_vec_std
  • wspd_vec_mean

sgp15ebbrE26.b1:
  • wdir_vec_mean_mv

sgp5ebbrE26.b1:
  • wdir_vec_mean
  • wdir_vec_std
  • wspd_vec_mean


Back To Table of Contents

DQRID : D050207.13
Start DateStart TimeEnd DateEnd Time
01/06/2005100501/07/20051430
Subject:
SGP/EBBR/E27  - Wind Direction Frozen Stopped By Ice Storm
DataStreams:sgp15ebbrE27.b1, sgp30ebbrE27.b1, sgp5ebbrE27.b1
Description:
The wind direction sensor was frozen stopped by ice from a storm.  
The wind direction, sigma_wd, and residual wind speed measurements 
are incorrect.
Measurements:sgp5ebbrE27.b1:
  • wdir_vec_mean
  • wdir_vec_std
  • wspd_vec_mean

sgp15ebbrE27.b1:
  • wdir_vec_mean_mv

sgp30ebbrE27.b1:
  • wdir_vec_mean
  • wdir_vec_std
  • wspd_vec_mean


Back To Table of Contents

DQRID : D050211.1
Start DateStart TimeEnd DateEnd Time
10/10/2004140002/17/20051630
Subject:
SGP/EBBR/E26 - Aging Pressure Sensor Output Changes
With Supply Voltage
DataStreams:sgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
Description:
The E26 EBBR pressure sensor experienced the poor internal voltage regulation problem 
experienced at other sites last year.  Aging of the internal voltage regulator caused the 
pressure output to drop by 1-2 kPa (0.1-0.5 kPa is normal) when the Sun rose and the solar 
panel goosed the battery voltage up.  

The sensible and latent heat fluxes were not significantly affected.
Measurements:sgp30ebbrE26.b1:
  • Barometric Pressure(atmos_pressure)

sgp15ebbrE26.b1:
  • atmos_pressure_mv

sgp5ebbrE26.b1:
  • Barometric Pressure(atmos_pressure)


Back To Table of Contents

DQRID : D050211.2
Start DateStart TimeEnd DateEnd Time
09/15/2004160003/07/20052100
Subject:
SGP/EBBR/E27 - Soil Moisture #5 Incorrect
DataStreams:sgp30ebbrE27.b1
Description:
The wrong CR10 program loaded from the storage module on 9/15/04.  During the previous 
change of program, an attempt was made to store the new program in the storage module; site 
ops techs did not notice that this attempt failed, leaving the old program in the storage 
module.  When power was cyled on 9/15/04, the old program with flat sm5 coefficients 
loaded into the CR10.  The "flat" coefficients resulted in the sm5 soil moisture hovering 
around 30%.

15 minute raw sm5 resistances were correct.

Average soil heat flow, sensible heat flux, and latent heat flux were not
significantly affected and so are not included in the list of incorrect measurements.
Measurements:sgp30ebbrE27.b1:
  • soil_moisture_5


Back To Table of Contents

DQRID : D050215.21
Start DateStart TimeEnd DateEnd Time
01/11/2005091501/11/20052100
Subject:
SGP/EBBR/E22  - Wind Speed Frozen Stopped By Ice
DataStreams:sgp15ebbrE22.b1, sgp30ebbrE22.b1, sgp5ebbrE22.b1
Description:
An ice storm froze the wind speed sensor to a stopped condition.

The wind speed and residual wind speed measurements are incorrect.

This sensor failure does not affect the sensible and latent heat fluxes.
Measurements:sgp30ebbrE22.b1:
  • wspd_vec_mean
  • wspd_arith_mean

sgp5ebbrE22.b1:
  • wspd_vec_mean
  • wspd_arith_mean

sgp15ebbrE22.b1:
  • wspd_arith_mean


Back To Table of Contents

DQRID : D050215.22
Start DateStart TimeEnd DateEnd Time
01/11/2005173001/11/20051825
Subject:
SGP/EBBR/E22  - Wind Direction Frozen Stopped By Ice
DataStreams:sgp15ebbrE22.b1, sgp30ebbrE22.b1, sgp5ebbrE22.b1
Description:
The wind direction sensor was frozen stopped by ice from a storm.  
The wind direction, sigma_wd, and residual wind speed measurements 
are incorrect.
Measurements:sgp30ebbrE22.b1:
  • wspd_vec_mean
  • wdir_vec_mean
  • wdir_vec_std

sgp5ebbrE22.b1:
  • wdir_vec_std
  • wdir_vec_mean
  • wspd_vec_mean

sgp15ebbrE22.b1:
  • wdir_vec_mean_mv


Back To Table of Contents

DQRID : D050323.2
Start DateStart TimeEnd DateEnd Time
03/06/2005140003/16/20051900
Subject:
SGP/EBBR/E22 - Net Radiation Too Low - Top Dome Broken
DataStreams:sgp15ebbrE22.b1, sgp30ebbrE22.b1, sgp5ebbrE22.b1
Description:
Net radiation values were too low because of a broken top dome.
Measurements:sgp30ebbrE22.b1:
  • latent_heat_flux
  • sensible_heat_flux
  • net_radiation

sgp5ebbrE22.b1:
  • net_radiation

sgp15ebbrE22.b1:
  • net_radiation_mv


Back To Table of Contents

DQRID : D050324.3
Start DateStart TimeEnd DateEnd Time
01/10/2003170003/03/20051600
Subject:
SGP/EBBR/E26 - Incorrect soil type coefficients used
DataStreams:sgp30ebbrE26.b1
Description:
The soil type coefficents for soil moisture were incorrect from the day
of the system installation on, making soil moisture values too large.

As a result, soil heat flows were overmeasured, and sensible and latent heat fluxes were 
underestimated.
Measurements:sgp30ebbrE26.b1:
  • surface_soil_heat_flux_avg
  • energy_storage_change_1
  • energy_storage_change_2
  • energy_storage_change_3
  • energy_storage_change_4
  • energy_storage_change_5
  • surface_soil_heat_flux_5
  • soil_moisture_5
  • surface_soil_heat_flux_3
  • surface_soil_heat_flux_4
  • soil_heat_capacity_5
  • soil_moisture_1
  • soil_heat_capacity_4
  • soil_moisture_2
  • soil_moisture_3
  • soil_moisture_4
  • soil_heat_capacity_2
  • soil_heat_capacity_3
  • soil_heat_capacity_1
  • latent_heat_flux
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_1
  • sensible_heat_flux
  • corr_soil_heat_flow_4
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_1
  • corr_soil_heat_flow_5


Back To Table of Contents

DQRID : D050404.1
Start DateStart TimeEnd DateEnd Time
03/30/2005200004/13/20051700
Subject:
SGP/EBBR/E20 - Wrong Datalogger Program Installed
DataStreams:sgp30ebbrE20.b1
Description:
ts4 went offscale and sm4 dropped to a constant 16% when a "new" program
was installed on 3/30/05.  The wrong program was installed.

Because ts4 did not change with time, it did not mess up the calculation
of e and h.  e and h are slightly overestimated, but only by about 1%,
far less than the system error. This is a rare type of instrument problem where the 
concequences are minimal.

Therefore, e and h are not listed as incorrect in this DQR and are still usable during the 
stated period.
Measurements:sgp30ebbrE20.b1:
  • soil_moisture_4
  • corr_soil_heat_flow_4
  • soil_heat_capacity_4
  • energy_storage_change_4
  • surface_soil_heat_flux_4
  • soil_temp_4


Back To Table of Contents

DQRID : D050404.4
Start DateStart TimeEnd DateEnd Time
03/20/2005123004/27/20052000
Subject:
SGP/EBBR/E20 - Temp. of thum_left Incorrect At Times
DataStreams:sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1
Description:
The temperature portion of the left T/RH probe temperature spiked at times.  This was 
caused by a faulty surge protector in the J-Panel.
Measurements:sgp5ebbrE20.b1:
  • vapor_pressure_top
  • temp_trh_top
  • temp_trh_bottom
  • vapor_pressure_bottom

sgp15ebbrE20.b1:
  • temp_trh_left_rr

sgp30ebbrE20.b1:
  • vapor_pressure_bottom
  • temp_trh_top
  • sensible_heat_flux
  • vapor_pressure_top
  • bowen_ratio
  • temp_trh_bottom
  • latent_heat_flux


Back To Table of Contents

DQRID : D050413.6
Start DateStart TimeEnd DateEnd Time
03/04/2004164503/02/20051600
Subject:
SGP/EBBR/E27 - SM2 Coefficients Incorect
DataStreams:sgp15ebbrE27.b1, sgp30ebbrE27.b1
Description:
Soil Moisture #2 coefficients in the CR10 datalogger program were incorrect during the 
time
that an old program version was installed.
Measurements:sgp15ebbrE27.b1:
  • soil_moisture_2_rr

sgp30ebbrE27.b1:
  • soil_moisture_2
  • surface_soil_heat_flux_2
  • soil_heat_capacity_2
  • corr_soil_heat_flow_2
  • energy_storage_change_2


Back To Table of Contents

DQRID : D050719.13
Start DateStart TimeEnd DateEnd Time
04/01/2001000003/30/20051900
Subject:
SGP/EBBR/E20 - Improved EBBR CR10 Program
DataStreams:sgp30ebbrE20.b1
Description:
Effective 20050330.1900, the EBBR.E20 CR10 program was revised to improve 
the quality of the primary measurements as follows:
   
1) An RMS procedure is used to determine max and min limits of acceptable
soil heat flow.  This is applied to the individual soil sets.  Measurements
outside the limits are rejected and the measurements within the limits are
used to calculate the average soil heat flow.
   
2) Max and min limits are used to determine incorrect values of net
radiation, sensible heat flux (h), latent heat flux (e), and automatic
exchange mechanism (AEM) signal.  If AEM signal is outside the limits, h 
and e are set to 999s.  If net radiation is outside the limits, h and e are 
set to 999s. If h or e are outside the limits, h and e are set to 999s.
   
Virtually no incorrect soil measurement will affect the primary 
measurements of h and e.
   
By setting h and e to 999s, it can be easily seen that the primary 
variables are incorrect; no other interpretation is possible.
   
Prior to 20050330, the improved CR10 program was NOT in effect.  DQRs have
been submitted for known instances of incorrect soil measurements which
affected the quality of the primary measurements of h and e.
   
Note: the DQR begin date is the begin date of the sgp30ebbrE20.b1 data
stream.  The earlier version of the CR10 program was also used on previous
EBBR datastream names (e.g. sgp30ebbrE20.a1).
Measurements:sgp30ebbrE20.b1:
  • sensible_heat_flux
  • surface_soil_heat_flux_avg
  • latent_heat_flux


Back To Table of Contents

DQRID : D050719.14
Start DateStart TimeEnd DateEnd Time
04/01/2001000003/30/20051930
Subject:
SGP/EBBR/E22 - Improved EBBR CR10 Program
DataStreams:sgp30ebbrE22.b1
Description:
Effective 20050330.1930, the EBBR.E20 CR10 program was revised to improve 
the quality of the primary measurements as follows:
   
1) An RMS procedure is used to determine max and min limits of acceptable
soil heat flow.  This is applied to the individual soil sets.  Measurements
outside the limits are rejected and the measurements within the limits are
used to calculate the average soil heat flow.
   
2) Max and min limits are used to determine incorrect values of net
radiation, sensible heat flux (h), latent heat flux (e), and automatic
exchange mechanism (AEM) signal.  If AEM signal is outside the limits, h 
and e are set to 999s.  If net radiation is outside the limits, h and e are 
set to 999s. If h or e are outside the limits, h and e are set to 999s.
   
Virtually no incorrect soil measurement will affect the primary 
measurements of h and e.
   
By setting h and e to 999s, it can be easily seen that the primary 
variables are incorrect; no other interpretation is possible.
   
Prior to 20050330, the improved CR10 program was NOT in effect.  DQRs have
been submitted for known instances of incorrect soil measurements which
affected the quality of the primary measurements of h and e.
   
Note: the DQR begin date is the begin date of the sgp30ebbrE20.b1 data
stream.  The earlier version of the CR10 program was also used on previous
EBBR datastream names (e.g. sgp30ebbrE20.a1).
Measurements:sgp30ebbrE22.b1:
  • latent_heat_flux
  • sensible_heat_flux
  • surface_soil_heat_flux_avg


Back To Table of Contents

DQRID : D050719.15
Start DateStart TimeEnd DateEnd Time
04/01/2001000003/31/20051700
Subject:
SGP/EBBR/E26 - Improved EBBR CR10 Program
DataStreams:sgp30ebbrE26.b1
Description:
Effective 20050331.1700, the EBBR.E26 CR10 program was revised to improve 
the quality of the primary measurements as follows:
   
1) An RMS procedure is used to determine max and min limits of acceptable
soil heat flow.  This is applied to the individual soil sets.  Measurements
outside the limits are rejected and the measurements within the limits are
used to calculate the average soil heat flow.
   
2) Max and min limits are used to determine incorrect values of net
radiation, sensible heat flux (h), latent heat flux (e), and automatic
exchange mechanism (AEM) signal.  If AEM signal is outside the limits, h 
and e are set to 999s.  If net radiation is outside the limits, h and e are 
set to 999s. If h or e are outside the limits, h and e are set to 999s.
   
Virtually no incorrect soil measurement will affect the primary 
measurements of h and e.
   
By setting h and e to 999s, it can be easily seen that the primary 
variables are incorrect; no other interpretation is possible.
   
Prior to 20050331, the improved CR10 program was NOT in effect.  DQRs have
been submitted for known instances of incorrect soil measurements which
affected the quality of the primary measurements of h and e.
   
Note: the DQR begin date is the begin date of the sgp30ebbrE26.b1 data
stream.  The earlier version of the CR10 program was also used on previous
EBBR datastream names (e.g. sgp30ebbrE26.a1).
~
Measurements:sgp30ebbrE26.b1:
  • surface_soil_heat_flux_avg
  • latent_heat_flux
  • sensible_heat_flux


Back To Table of Contents

DQRID : D050719.16
Start DateStart TimeEnd DateEnd Time
05/07/2003000003/30/20051730
Subject:
SGP/EBBR/E27 - Improved EBBR CR10 Program
DataStreams:sgp30ebbrE27.b1
Description:
Effective 20050330.1730, the EBBR.E27 CR10 program was revised to improve 
the quality of the primary measurements as follows:
   
1) An RMS procedure is used to determine max and min limits of acceptable
soil heat flow.  This is applied to the individual soil sets.  Measurements
outside the limits are rejected and the measurements within the limits are
used to calculate the average soil heat flow.
   
2) Max and min limits are used to determine incorrect values of net
radiation, sensible heat flux (h), latent heat flux (e), and automatic
exchange mechanism (AEM) signal.  If AEM signal is outside the limits, h 
and e are set to 999s.  If net radiation is outside the limits, h and e are 
set to 999s. If h or e are outside the limits, h and e are set to 999s.
   
Virtually no incorrect soil measurement will affect the primary 
measurements of h and e.
   
By setting h and e to 999s, it can be easily seen that the primary 
variables are incorrect; no other interpretation is possible.
   
Prior to 20050330, the improved CR10 program was NOT in effect.  DQRs have
been submitted for known instances of incorrect soil measurements which
affected the quality of the primary measurements of h and e.
   
Note: the DQR begin date is the begin date of the sgp30ebbrE27.b1 data
stream.  The earlier version of the CR10 program was also used on previous
EBBR datastream names (e.g. sgp30ebbrE27.a1).
Measurements:sgp30ebbrE27.b1:
  • latent_heat_flux
  • sensible_heat_flux
  • surface_soil_heat_flux_avg


Back To Table of Contents

DQRID : D050922.2
Start DateStart TimeEnd DateEnd Time
07/05/2005173007/06/20051930
08/23/2005190008/31/20051700
09/01/2005173009/02/20050300
09/02/2005110009/15/20052230
09/16/2005010009/28/20051830
Subject:
SGP/EBBR/E20 - Soil Temperature and Soil Moisture  #4 Measurements Incorrect
DataStreams:sgp15ebbrE20.b1, sgp30ebbrE20.b1
Description:
The ts4 sensor reported 99999 values because the sensor leads were loose.  Soil moisture 
#4 reported low values (steady 16%) during this time period.

The sensible and latent heat fluxes were not affected by this problem, only
soil temperature and soil moisture #4.  See soil temperatures and soil moistures from sets 
#2, #3, and #5 for correct values (note: soil temperature #1 was having problems during 
the same time).
Measurements:sgp15ebbrE20.b1:
  • soil_moisture_4_rr
  • soil_temp_4_rr

sgp30ebbrE20.b1:
  • soil_moisture_4
  • soil_heat_capacity_4
  • energy_storage_change_4
  • surface_soil_heat_flux_4
  • soil_temp_4


Back To Table of Contents

DQRID : D051106.13
Start DateStart TimeEnd DateEnd Time
08/27/2005200008/31/20051730
Subject:
SGP/EBBR/E22 - Net Radiation Incorrect; Sensible and Latent Heat Fluxes Incorrect
DataStreams:sgp15ebbrE22.b1, sgp30ebbrE22.b1, sgp5ebbrE22.b1
Description:
The net radiometer top dome was broken and water got inside, making the net radiation, and 
sensible and latent heat flux measurements incorrect.
Measurements:sgp30ebbrE22.b1:
  • latent_heat_flux
  • sensible_heat_flux
  • net_radiation

sgp5ebbrE22.b1:
  • net_radiation

sgp15ebbrE22.b1:
  • net_radiation_mv


Back To Table of Contents

DQRID : D051106.15
Start DateStart TimeEnd DateEnd Time
08/05/2005220008/17/20051600
Subject:
SGP/EBBR/E27 - Net Radiation Incorrect; Sensible and Latent Heat Fluxes Incorrect
DataStreams:sgp15ebbrE27.b1, sgp30ebbrE27.b1, sgp5ebbrE27.b1
Description:
The net radiometer top dome was broken and water got inside, making the net radiation, and 
sensible and latent heat flux measurements incorrect.
Measurements:sgp5ebbrE27.b1:
  • net_radiation

sgp15ebbrE27.b1:
  • net_radiation_mv

sgp30ebbrE27.b1:
  • latent_heat_flux
  • net_radiation
  • sensible_heat_flux


Back To Table of Contents

DQRID : D051106.16
Start DateStart TimeEnd DateEnd Time
08/17/2005163008/27/20051930
Subject:
SGP/EBBR/E27 - Net Radiation Incorrect; Sensible and Latent Heat Fluxes Incorredt
DataStreams:sgp15ebbrE27.b1, sgp30ebbrE27.b1, sgp5ebbrE27.b1
Description:
Residual Moisture left in the top dome of the net radiometer after the 8/17/05 servicing 
caused the net radiation measurements to be biased low, and resulting in sensible and 
latent heat flux being low also.
Measurements:sgp5ebbrE27.b1:
  • net_radiation

sgp15ebbrE27.b1:
  • net_radiation_mv

sgp30ebbrE27.b1:
  • latent_heat_flux
  • net_radiation
  • sensible_heat_flux


Back To Table of Contents

DQRID : D051106.28
Start DateStart TimeEnd DateEnd Time
03/02/2005190003/30/20051900
Subject:
SGP/EBBR/E20 - Average Soil Heat Flux Incorrect
DataStreams:sgp30ebbrE20.b1
Description:
A typo in the version 9 EBBR program caused average soil heat flow to be zero, resulting 
in both sensible and latent heat fluxes being approximately 20 watts per meter squared too 
large during the middle of the day.
Measurements:sgp30ebbrE20.b1:
  • sensible_heat_flux
  • surface_soil_heat_flux_avg
  • latent_heat_flux


Back To Table of Contents

DQRID : D051106.29
Start DateStart TimeEnd DateEnd Time
03/16/2005183003/30/20051930
Subject:
SGP/EBBR/E22 - Average Soil Heat Flux Incorrect
DataStreams:sgp30ebbrE22.b1
Description:
A typo in the version 9 EBBR program caused average soil heat flow to be zero, resulting 
in both sensible and latent heat fluxes being approximately 20 watts per meter squared too 
large during the middle of the day.
Measurements:sgp30ebbrE22.b1:
  • latent_heat_flux
  • sensible_heat_flux
  • surface_soil_heat_flux_avg


Back To Table of Contents

DQRID : D051106.30
Start DateStart TimeEnd DateEnd Time
03/03/2005180003/31/20051700
Subject:
SGP/EBBR/E26 - Average Soil Heat Flux Incorrect
DataStreams:sgp30ebbrE26.b1
Description:
A typo in the version 9 EBBR program caused average soil heat flow to be zero, resulting 
in both sensible and latent heat fluxes being approximately 20 watts per meter squared too 
large during the middle of the day.
Measurements:sgp30ebbrE26.b1:
  • surface_soil_heat_flux_avg
  • latent_heat_flux
  • sensible_heat_flux


Back To Table of Contents

DQRID : D051106.31
Start DateStart TimeEnd DateEnd Time
03/02/2005160003/30/20051730
Subject:
SGP/EBBR/E27 - Average Soil Heat Flux Incorrect
DataStreams:sgp30ebbrE27.b1
Description:
A typo in the version 9 EBBR program caused average soil heat flow to be zero, resulting 
in both sensible and latent heat fluxes being approximately 20 watts per meter squared too 
large during the middle of the day.
Measurements:sgp30ebbrE27.b1:
  • latent_heat_flux
  • sensible_heat_flux
  • surface_soil_heat_flux_avg


Back To Table of Contents

DQRID : D051112.10
Start DateStart TimeEnd DateEnd Time
10/13/2003000008/16/20052359
Subject:
SGP/EBBR/E27 - metadata corrections
DataStreams:sgp15ebbrE27.b1, sgp30ebbrE27.b1, sgp5ebbrE27.b1
Description:
On 20050816, a series of metadata corrections and additions were completed.  These 
metadata changes apply to all EBBR.E27 data collected by ARM back to the installation of the 
instrument in May 2003. Please see the current metadata for correct information.  These 
changes do not affect data values or quality.	

The changes are summarized below:
1) Update of "sensor location" information
2) Addition of installation dates for the systems
3) Correction of soil moisture units (from "by volume" to "gravimetric")
Measurements:sgp5ebbrE27.b1:
  • base time(base_time)

sgp15ebbrE27.b1:
  • base time(base_time)

sgp30ebbrE27.b1:
  • base time(base_time)


Back To Table of Contents

DQRID : D051112.7
Start DateStart TimeEnd DateEnd Time
10/15/2003000007/22/20052359
Subject:
SGP/EBBR/E20 - metadata corrections
DataStreams:sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1
Description:
On 20050723, a series of metadata corrections and additions were completed.  These 
metadata changes apply to all EBBR.E20 data collected by ARM back to the installation of the 
instrument in April 1993. Please see the current metadata for correct information.  These 
changes do not
affect data values or quality.	

The changes are summarized below:
1) Update of "sensor location" information
2) Addition of installation dates for the systems
3) Correction of soil moisture units (from "by volume" to "gravimetric")
Measurements:sgp5ebbrE20.b1:
  • base time(base_time)

sgp15ebbrE20.b1:
  • base time(base_time)

sgp30ebbrE20.b1:
  • base time(base_time)


Back To Table of Contents

DQRID : D051112.8
Start DateStart TimeEnd DateEnd Time
10/13/2003000007/22/20052359
Subject:
SGP/EBBR/E22 - metadata corrections
DataStreams:sgp15ebbrE22.b1, sgp30ebbrE22.b1, sgp5ebbrE22.b1
Description:
On 20050723, a series of metadata corrections and additions were completed.  These 
metadata changes apply to all EBBR.E22 data collected by ARM back to the installation of the 
instrument in April 1993. Please see the current metadata for correct information.  These 
changes do not affect data values or quality.	

The changes are summarized below:
1) Update of "sensor location" information
2) Addition of installation dates for the systems
3) Correction of soil type
4) Correction of soil moisture units (from "by volume" to "gravimetric")
Measurements:sgp30ebbrE22.b1:
  • base time(base_time)

sgp5ebbrE22.b1:
  • base time(base_time)

sgp15ebbrE22.b1:
  • base time(base_time)


Back To Table of Contents

DQRID : D051112.9
Start DateStart TimeEnd DateEnd Time
10/13/2003000007/22/20052359
Subject:
SGP/EBBR/E26 - metadata corrections
DataStreams:sgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
Description:
On 20050723, a series of metadata corrections and additions were completed.  These 
metadata changes apply to all EBBR.E26 data collected by ARM back to the installation of the 
instrument in June 1992. Please see the current metadata for correct information.  These 
changes do not affect data values or quality.	

The changes are summarized below:
1) Update of "sensor location" information
2) Addition of installation dates for the systems
3) Correction of soil moisture units (from "by volume" to "gravimetric")
Measurements:sgp30ebbrE26.b1:
  • base time(base_time)

sgp15ebbrE26.b1:
  • base time(base_time)

sgp5ebbrE26.b1:
  • base time(base_time)


Back To Table of Contents

DQRID : D051115.10
Start DateStart TimeEnd DateEnd Time
04/01/2001000004/08/20022359
Subject:
SGP/EBBR/E25 - metadata errors
DataStreams:sgp15ebbrE25.b1, sgp30ebbrE25.b1
Description:
During the entire span of EBBR.E25 data, the cdf data files contained a few minor global 
metadata errors. These errors do not affect the data values or quality.

The errors include:
* incomplete sensor location information
* incomplete installation date information
* soil moisture documented as "by volume" should have read "gravimetric"
Measurements:sgp30ebbrE25.b1:
  • base time(base_time)

sgp15ebbrE25.b1:
  • base time(base_time)


Back To Table of Contents

DQRID : D051222.1
Start DateStart TimeEnd DateEnd Time
12/20/2005080012/22/20051500
Subject:
SGP/EBBR/E26 - Data Suspect During Low Supply Voltage
DataStreams:sgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
Description:
Low battery supply voltage resulted in high home signals and questionable data at times.
Data for battery voltage <10.5 volts should be considered to be incorrect.
Measurements:sgp30ebbrE26.b1:
  • wspd_vec_mean
  • rh_top_fraction
  • wspd_arith_mean
  • latent_heat_flux
  • vapor_pressure_top
  • vapor_pressure_bottom
  • corr_soil_heat_flow_4
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_1
  • temp_reference
  • corr_soil_heat_flow_5
  • wdir_vec_std
  • temp_air_top
  • surface_soil_heat_flux_5
  • soil_moisture_5
  • surface_soil_heat_flux_3
  • surface_soil_heat_flux_4
  • soil_moisture_1
  • soil_moisture_2
  • soil_moisture_3
  • soil_moisture_4
  • temp_trh_top
  • rh_bottom_fraction
  • home_signal_15
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_1
  • lon(lon)
  • sensible_heat_flux
  • surface_soil_heat_flux_avg
  • net_radiation
  • soil_heat_capacity_5
  • soil_heat_capacity_4
  • soil_heat_capacity_2
  • soil_heat_capacity_3
  • bowen_ratio
  • home_signal_30
  • soil_heat_capacity_1
  • lat(lat)
  • soil_temp_5
  • soil_temp_4
  • soil_heat_flow_3
  • soil_temp_3
  • soil_heat_flow_2
  • soil_temp_2
  • soil_heat_flow_1
  • soil_temp_1
  • soil_heat_flow_5
  • soil_heat_flow_4
  • temp_air_bottom
  • wdir_vec_mean
  • energy_storage_change_1
  • energy_storage_change_2
  • energy_storage_change_3
  • Time offset of tweaks from base_time(time_offset)
  • energy_storage_change_4
  • energy_storage_change_5
  • temp_trh_bottom
  • Dummy altitude for Zeb(alt)
  • Barometric Pressure(atmos_pressure)
  • base time(base_time)

sgp15ebbrE26.b1:
  • wdir_vec_mean_mv
  • soil_heat_flow_4_mv
  • soil_moisture_4_rr
  • soil_heat_flow_3_mv
  • soil_temp_1_rr
  • soil_moisture_5_rr
  • temp_trh_right_rr
  • soil_heat_flow_2_mv
  • battery_voltage
  • lon(lon)
  • soil_temp_3_rr
  • soil_moisture_2_rr
  • soil_heat_flow_1_mv
  • soil_temp_4_rr
  • temp_trh_left_rr
  • lat(lat)
  • temp_air_left
  • Dummy altitude for Zeb(alt)
  • rh_right_mv
  • soil_moisture_3_rr
  • home_signal
  • soil_moisture_1_rr
  • temp_air_right
  • rh_left_mv
  • soil_temp_5_rr
  • soil_heat_flow_5_mv
  • temp_reference_rr
  • Time offset of tweaks from base_time(time_offset)
  • base time(base_time)
  • soil_temp_2_rr
  • wspd_arith_mean
  • atmos_pressure_mv
  • net_radiation_mv

sgp5ebbrE26.b1:
  • temp_trh_bottom
  • lon(lon)
  • wspd_arith_mean
  • wdir_vec_std
  • time(time)
  • rh_top_fraction
  • home_signal
  • Barometric Pressure(atmos_pressure)
  • Time offset of tweaks from base_time(time_offset)
  • rh_bottom_fraction
  • temp_reference
  • wdir_vec_mean
  • temp_trh_top
  • temp_air_top
  • wspd_vec_mean
  • temp_air_bottom
  • vapor_pressure_bottom
  • Dummy altitude for Zeb(alt)
  • vapor_pressure_top
  • net_radiation
  • lat(lat)
  • base time(base_time)


Back To Table of Contents

DQRID : D060111.13
Start DateStart TimeEnd DateEnd Time
12/21/2005093012/21/20051730
Subject:
SGP/EBBR/E20 - Data Incorrect During J-Panel Replacement
DataStreams:sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1
Description:
Much of the data was incorrect during replacement of J-Panel #1.
Measurements:sgp5ebbrE20.b1:
  • Barometric Pressure(atmos_pressure)
  • lon(lon)
  • temp_reference
  • temp_air_top
  • temp_trh_top
  • home_signal
  • time(time)
  • wspd_arith_mean
  • base time(base_time)
  • wspd_vec_mean
  • temp_trh_bottom
  • lat(lat)
  • rh_top_fraction
  • net_radiation
  • wdir_vec_mean
  • temp_air_bottom
  • Dummy altitude for Zeb(alt)
  • rh_bottom_fraction
  • vapor_pressure_bottom
  • vapor_pressure_top
  • Time offset of tweaks from base_time(time_offset)
  • wdir_vec_std

sgp15ebbrE20.b1:
  • atmos_pressure_mv
  • wspd_arith_mean
  • wdir_vec_mean_mv
  • soil_heat_flow_3_mv
  • net_radiation_mv
  • soil_moisture_1_rr
  • rh_left_mv
  • soil_heat_flow_4_mv
  • soil_heat_flow_2_mv
  • base time(base_time)
  • battery_voltage
  • temp_air_left
  • rh_right_mv
  • temp_air_right
  • soil_moisture_2_rr
  • Time offset of tweaks from base_time(time_offset)
  • soil_temp_2_rr
  • home_signal
  • soil_temp_3_rr
  • lat(lat)
  • temp_trh_right_rr
  • Dummy altitude for Zeb(alt)
  • soil_moisture_4_rr
  • soil_heat_flow_5_mv
  • soil_temp_4_rr
  • lon(lon)
  • soil_moisture_3_rr
  • soil_heat_flow_1_mv
  • temp_trh_left_rr
  • temp_reference_rr
  • soil_temp_1_rr
  • soil_temp_5_rr
  • soil_moisture_5_rr

sgp30ebbrE20.b1:
  • temp_air_top
  • home_signal_15
  • temp_air_bottom
  • soil_heat_capacity_2
  • soil_heat_capacity_3
  • soil_heat_capacity_4
  • soil_heat_capacity_5
  • soil_heat_capacity_1
  • sensible_heat_flux
  • wspd_arith_mean
  • Dummy altitude for Zeb(alt)
  • wdir_vec_mean
  • soil_temp_3
  • soil_temp_4
  • soil_temp_5
  • soil_temp_1
  • Barometric Pressure(atmos_pressure)
  • soil_temp_2
  • soil_heat_flow_1
  • soil_heat_flow_3
  • soil_heat_flow_2
  • soil_heat_flow_5
  • soil_heat_flow_4
  • surface_soil_heat_flux_avg
  • base time(base_time)
  • temp_trh_bottom
  • wdir_vec_std
  • Time offset of tweaks from base_time(time_offset)
  • lat(lat)
  • corr_soil_heat_flow_5
  • corr_soil_heat_flow_4
  • corr_soil_heat_flow_3
  • net_radiation
  • rh_bottom_fraction
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_1
  • temp_trh_top
  • soil_moisture_4
  • soil_moisture_3
  • soil_moisture_5
  • temp_reference
  • bowen_ratio
  • rh_top_fraction
  • wspd_vec_mean
  • soil_moisture_2
  • soil_moisture_1
  • surface_soil_heat_flux_5
  • lon(lon)
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_1
  • surface_soil_heat_flux_4
  • surface_soil_heat_flux_3
  • latent_heat_flux
  • vapor_pressure_bottom
  • home_signal_30
  • energy_storage_change_1
  • energy_storage_change_3
  • energy_storage_change_2
  • energy_storage_change_5
  • energy_storage_change_4
  • vapor_pressure_top


Back To Table of Contents

DQRID : D060112.1
Start DateStart TimeEnd DateEnd Time
01/10/2006073001/18/20062000
Subject:
SGP/EBBR/E22 - Sensible and Latent Heat Fluxes Incorrect
DataStreams:sgp15ebbrE22.b1, sgp30ebbrE22.b1, sgp5ebbrE22.b1
Description:
Measurements:sgp30ebbrE22.b1:
  • vapor_pressure_top
  • bowen_ratio
  • sensible_heat_flux
  • temp_air_top
  • temp_trh_top
  • temp_air_bottom
  • latent_heat_flux
  • rh_bottom_fraction
  • temp_trh_bottom
  • rh_top_fraction
  • vapor_pressure_bottom

sgp5ebbrE22.b1:
  • vapor_pressure_top
  • rh_bottom_fraction
  • temp_trh_top
  • vapor_pressure_bottom
  • temp_air_top
  • rh_top_fraction
  • temp_trh_bottom
  • temp_air_bottom

sgp15ebbrE22.b1:
  • temp_air_left
  • temp_air_right


Back To Table of Contents

DQRID : D060425.1
Start DateStart TimeEnd DateEnd Time
03/03/2006000005/10/20061130
05/25/2006210006/20/20061730
Subject:
SGP/EBBR/E27 - Sensible and Latent Heat Fluxes Incorrect
DataStreams:sgp15ebbrE27.b1, sgp30ebbrE27.b1, sgp5ebbrE27.b1
Description:
The left T/RH probe temperature sensor was spiking some of the time during these periods. 
Therefore, sensible and latent heat fluxes were incorrect during parts of the periods as 
well.
Measurements:sgp5ebbrE27.b1:
  • vapor_pressure_top
  • temp_trh_bottom
  • temp_trh_top
  • vapor_pressure_bottom

sgp15ebbrE27.b1:
  • temp_trh_left_rr

sgp30ebbrE27.b1:
  • latent_heat_flux
  • temp_trh_bottom
  • temp_trh_top
  • vapor_pressure_top
  • sensible_heat_flux
  • vapor_pressure_bottom
  • bowen_ratio


Back To Table of Contents

DQRID : D060428.4
Start DateStart TimeEnd DateEnd Time
04/12/2006190005/24/20061700
Subject:
SGP/EBBR/E22 - Fluxes Incorrect When Soil Heat Flow #3 Out of Range
DataStreams:sgp30ebbrE22.b1
Description:
When soil heat flow #3 exceeded the range limit in the EBBR program, it was replaced with 
9999es.  This caused the ave_shf and the sensible and latent heat fluxes to be incorrect.
Measurements:sgp30ebbrE22.b1:
  • latent_heat_flux
  • sensible_heat_flux
  • corr_soil_heat_flow_1
  • soil_heat_flow_1
  • surface_soil_heat_flux_1
  • surface_soil_heat_flux_avg


Back To Table of Contents

DQRID : D060501.22
Start DateStart TimeEnd DateEnd Time
02/22/2006030002/25/20061630
Subject:
SGP/EBBR/E20 - Suspect Measurements
DataStreams:sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1
Description:
Some measurements may be incorrect because of low supply voltage.
Measurements:sgp5ebbrE20.b1:
  • Barometric Pressure(atmos_pressure)
  • lon(lon)
  • temp_reference
  • temp_air_top
  • temp_trh_top
  • home_signal
  • time(time)
  • wspd_arith_mean
  • base time(base_time)
  • wspd_vec_mean
  • temp_trh_bottom
  • lat(lat)
  • rh_top_fraction
  • net_radiation
  • wdir_vec_mean
  • temp_air_bottom
  • Dummy altitude for Zeb(alt)
  • rh_bottom_fraction
  • vapor_pressure_bottom
  • vapor_pressure_top
  • Time offset of tweaks from base_time(time_offset)
  • wdir_vec_std

sgp15ebbrE20.b1:
  • atmos_pressure_mv
  • wspd_arith_mean
  • wdir_vec_mean_mv
  • soil_heat_flow_3_mv
  • net_radiation_mv
  • soil_moisture_1_rr
  • rh_left_mv
  • soil_heat_flow_4_mv
  • soil_heat_flow_2_mv
  • base time(base_time)
  • battery_voltage
  • temp_air_left
  • rh_right_mv
  • temp_air_right
  • soil_moisture_2_rr
  • Time offset of tweaks from base_time(time_offset)
  • soil_temp_2_rr
  • home_signal
  • soil_temp_3_rr
  • lat(lat)
  • temp_trh_right_rr
  • Dummy altitude for Zeb(alt)
  • soil_moisture_4_rr
  • soil_heat_flow_5_mv
  • soil_temp_4_rr
  • lon(lon)
  • soil_moisture_3_rr
  • soil_heat_flow_1_mv
  • temp_trh_left_rr
  • temp_reference_rr
  • soil_temp_1_rr
  • soil_temp_5_rr
  • soil_moisture_5_rr

sgp30ebbrE20.b1:
  • temp_air_top
  • home_signal_15
  • temp_air_bottom
  • soil_heat_capacity_2
  • soil_heat_capacity_3
  • soil_heat_capacity_4
  • soil_heat_capacity_5
  • soil_heat_capacity_1
  • sensible_heat_flux
  • wspd_arith_mean
  • Dummy altitude for Zeb(alt)
  • wdir_vec_mean
  • soil_temp_3
  • soil_temp_4
  • soil_temp_5
  • soil_temp_1
  • Barometric Pressure(atmos_pressure)
  • soil_temp_2
  • soil_heat_flow_1
  • soil_heat_flow_3
  • soil_heat_flow_2
  • soil_heat_flow_5
  • soil_heat_flow_4
  • surface_soil_heat_flux_avg
  • base time(base_time)
  • temp_trh_bottom
  • wdir_vec_std
  • Time offset of tweaks from base_time(time_offset)
  • lat(lat)
  • corr_soil_heat_flow_5
  • corr_soil_heat_flow_4
  • corr_soil_heat_flow_3
  • net_radiation
  • rh_bottom_fraction
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_1
  • temp_trh_top
  • soil_moisture_4
  • soil_moisture_3
  • soil_moisture_5
  • temp_reference
  • bowen_ratio
  • rh_top_fraction
  • wspd_vec_mean
  • soil_moisture_2
  • soil_moisture_1
  • surface_soil_heat_flux_5
  • lon(lon)
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_1
  • surface_soil_heat_flux_4
  • surface_soil_heat_flux_3
  • latent_heat_flux
  • vapor_pressure_bottom
  • home_signal_30
  • energy_storage_change_1
  • energy_storage_change_3
  • energy_storage_change_2
  • energy_storage_change_5
  • energy_storage_change_4
  • vapor_pressure_top


Back To Table of Contents

DQRID : D060501.25
Start DateStart TimeEnd DateEnd Time
01/21/2006113001/21/20061700
01/22/2006010001/22/20060730
Subject:
SGP/EBBR/E22 - Wind Speed Sensor Frozen Stopped
DataStreams:sgp15ebbrE22.b1, sgp30ebbrE22.b1, sgp5ebbrE22.b1
Description:
The wind speed sensor was frozen to a stopped condition.
Measurements:sgp30ebbrE22.b1:
  • wspd_vec_mean
  • wspd_arith_mean

sgp5ebbrE22.b1:
  • wspd_vec_mean
  • wspd_arith_mean

sgp15ebbrE22.b1:
  • wspd_arith_mean


Back To Table of Contents

DQRID : D060501.26
Start DateStart TimeEnd DateEnd Time
02/21/2006040002/25/20061700
Subject:
SGP/EBBR/E26 - Measurements Incorrect
DataStreams:sgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
Description:
Most measurements were incorrect during low battery voltage conditions.
Measurements:sgp30ebbrE26.b1:
  • wspd_vec_mean
  • rh_top_fraction
  • wspd_arith_mean
  • latent_heat_flux
  • vapor_pressure_top
  • vapor_pressure_bottom
  • corr_soil_heat_flow_4
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_1
  • temp_reference
  • corr_soil_heat_flow_5
  • wdir_vec_std
  • temp_air_top
  • surface_soil_heat_flux_5
  • soil_moisture_5
  • surface_soil_heat_flux_3
  • surface_soil_heat_flux_4
  • soil_moisture_1
  • soil_moisture_2
  • soil_moisture_3
  • soil_moisture_4
  • temp_trh_top
  • rh_bottom_fraction
  • home_signal_15
  • surface_soil_heat_flux_2
  • surface_soil_heat_flux_1
  • lon(lon)
  • sensible_heat_flux
  • surface_soil_heat_flux_avg
  • net_radiation
  • soil_heat_capacity_5
  • soil_heat_capacity_4
  • soil_heat_capacity_2
  • soil_heat_capacity_3
  • bowen_ratio
  • home_signal_30
  • soil_heat_capacity_1
  • lat(lat)
  • soil_temp_5
  • soil_temp_4
  • soil_heat_flow_3
  • soil_temp_3
  • soil_heat_flow_2
  • soil_temp_2
  • soil_heat_flow_1
  • soil_temp_1
  • soil_heat_flow_5
  • soil_heat_flow_4
  • temp_air_bottom
  • wdir_vec_mean
  • energy_storage_change_1
  • energy_storage_change_2
  • energy_storage_change_3
  • Time offset of tweaks from base_time(time_offset)
  • energy_storage_change_4
  • energy_storage_change_5
  • temp_trh_bottom
  • Dummy altitude for Zeb(alt)
  • Barometric Pressure(atmos_pressure)
  • base time(base_time)

sgp15ebbrE26.b1:
  • wdir_vec_mean_mv
  • soil_heat_flow_4_mv
  • soil_moisture_4_rr
  • soil_heat_flow_3_mv
  • soil_temp_1_rr
  • soil_moisture_5_rr
  • temp_trh_right_rr
  • soil_heat_flow_2_mv
  • battery_voltage
  • lon(lon)
  • soil_temp_3_rr
  • soil_moisture_2_rr
  • soil_heat_flow_1_mv
  • soil_temp_4_rr
  • temp_trh_left_rr
  • lat(lat)
  • temp_air_left
  • Dummy altitude for Zeb(alt)
  • rh_right_mv
  • soil_moisture_3_rr
  • home_signal
  • soil_moisture_1_rr
  • temp_air_right
  • rh_left_mv
  • soil_temp_5_rr
  • soil_heat_flow_5_mv
  • temp_reference_rr
  • Time offset of tweaks from base_time(time_offset)
  • base time(base_time)
  • soil_temp_2_rr
  • wspd_arith_mean
  • atmos_pressure_mv
  • net_radiation_mv

sgp5ebbrE26.b1:
  • temp_trh_bottom
  • lon(lon)
  • wspd_arith_mean
  • wdir_vec_std
  • time(time)
  • rh_top_fraction
  • home_signal
  • Barometric Pressure(atmos_pressure)
  • Time offset of tweaks from base_time(time_offset)
  • rh_bottom_fraction
  • temp_reference
  • wdir_vec_mean
  • temp_trh_top
  • temp_air_top
  • wspd_vec_mean
  • temp_air_bottom
  • vapor_pressure_bottom
  • Dummy altitude for Zeb(alt)
  • vapor_pressure_top
  • net_radiation
  • lat(lat)
  • base time(base_time)


Back To Table of Contents

DQRID : D060501.27
Start DateStart TimeEnd DateEnd Time
02/18/2006033003/01/20061615
Subject:
SGP/EBBR/E27 - Flux and Gradient Measurements Incorrect
DataStreams:sgp15ebbrE27.b1, sgp30ebbrE27.b1, sgp5ebbrE27.b1
Description:
The sensible and latent heat flux and gradient measurements were incorrect
while the AEM was hung in one position.
Measurements:sgp5ebbrE27.b1:
  • temp_trh_bottom
  • temp_air_bottom
  • rh_top_fraction
  • temp_air_top
  • rh_bottom_fraction
  • vapor_pressure_top
  • temp_trh_top
  • vapor_pressure_bottom

sgp15ebbrE27.b1:
  • temp_trh_right_rr
  • rh_right_mv
  • temp_air_right
  • temp_air_left
  • rh_left_mv
  • temp_trh_left_rr

sgp30ebbrE27.b1:
  • latent_heat_flux
  • temp_air_top
  • sensible_heat_flux
  • rh_bottom_fraction
  • rh_top_fraction
  • temp_air_bottom
  • temp_trh_bottom
  • temp_trh_top
  • vapor_pressure_top
  • bowen_ratio
  • vapor_pressure_bottom


Back To Table of Contents

DQRID : D060508.3
Start DateStart TimeEnd DateEnd Time
03/09/2006190004/16/20061600
Subject:
SGP/EBBR/E27 - Instrument problem, Loose connections
DataStreams:sgp15ebbrE27.b1, sgp30ebbrE27.b1
Description:
The soil heat flow #1 sensor went offscale low on occasion.  This sometimes caused 
sensible and latent heat fluxes to be 9999ed out by the EBBR programming, but not always.
Measurements:sgp15ebbrE27.b1:
  • soil_heat_flow_1_mv

sgp30ebbrE27.b1:
  • corr_soil_heat_flow_1
  • latent_heat_flux
  • surface_soil_heat_flux_1
  • soil_heat_flow_1
  • sensible_heat_flux


Back To Table of Contents

DQRID : D060622.6
Start DateStart TimeEnd DateEnd Time
06/17/2006090006/20/20061915
Subject:
SGP/EBBR/E20 - Net Radiation, Fluxes Too Large
DataStreams:sgp30ebbrE20.b1, sgp5ebbrE20.b1
Description:
Net Radiation was way too large because of water in the bottom dome.
This resulted in the sensible and latent heat fluxes being too large also.
Measurements:sgp5ebbrE20.b1:
  • net_radiation

sgp30ebbrE20.b1:
  • net_radiation
  • sensible_heat_flux
  • latent_heat_flux


Back To Table of Contents

DQRID : D060712.1
Start DateStart TimeEnd DateEnd Time
07/11/2006013007/21/20061730
Subject:
SGP/EBBR/E27 - Field fire burned AEM
DataStreams:sgp15ebbrE27.b1, sgp30ebbrE27.b1, sgp5ebbrE27.b1
Description:
A fire in the E27 field burned the AEM, making it non-functional.
Sensible and latent heat fluxes and gradients were incorrect during this period.
Measurements:sgp5ebbrE27.b1:
  • temp_trh_bottom
  • temp_air_bottom
  • rh_top_fraction
  • temp_air_top
  • home_signal
  • rh_bottom_fraction
  • vapor_pressure_top
  • temp_trh_top
  • vapor_pressure_bottom

sgp15ebbrE27.b1:
  • home_signal
  • temp_trh_right_rr
  • rh_right_mv
  • temp_air_right
  • temp_air_left
  • rh_left_mv
  • temp_trh_left_rr

sgp30ebbrE27.b1:
  • latent_heat_flux
  • temp_air_top
  • sensible_heat_flux
  • home_signal_30
  • rh_bottom_fraction
  • home_signal_15
  • rh_top_fraction
  • temp_air_bottom
  • temp_trh_bottom
  • temp_trh_top
  • vapor_pressure_top
  • vapor_pressure_bottom
  • bowen_ratio


Back To Table of Contents

DQRID : D060809.1
Start DateStart TimeEnd DateEnd Time
05/04/2006193005/04/20062200
05/05/2006023005/05/20060800
05/06/2006043006/20/20061730
Subject:
SGP/EBBR/E27 - Sensible, Latent, and Average Soil Heat Fluxes Sometimes Incorrect
DataStreams:sgp15ebbrE27.b1, sgp30ebbrE27.b1
Description:
The Soil Heat Flow #1 sensor kept going offscale.

Sensible and Latent heat fluxes and the ave_shf were affected and sometimes
incorrect.
Measurements:sgp15ebbrE27.b1:
  • soil_heat_flow_1_mv

sgp30ebbrE27.b1:
  • corr_soil_heat_flow_1
  • latent_heat_flux
  • surface_soil_heat_flux_1
  • soil_heat_flow_1
  • sensible_heat_flux
  • surface_soil_heat_flux_avg


Back To Table of Contents

DQRID : D060809.2
Start DateStart TimeEnd DateEnd Time
05/31/2006060006/07/20061730
06/14/2006050006/20/20061730
Subject:
SGP/EBBR/E27 - Low Battery Condition
DataStreams:sgp15ebbrE27.b1, sgp30ebbrE27.b1, sgp5ebbrE27.b1
Description:
A low battery condition caused most of the measurements to be incorrect.
Measurements:sgp5ebbrE27.b1:
  • rh_top_fraction
  • temp_reference
  • vapor_pressure_bottom
  • temp_trh_bottom
  • temp_air_bottom
  • home_signal
  • time(time)
  • wspd_vec_mean
  • wdir_vec_std
  • wspd_arith_mean
  • rh_bottom_fraction
  • temp_air_top
  • wdir_vec_mean
  • net_radiation
  • Barometric Pressure(atmos_pressure)
  • vapor_pressure_top
  • temp_trh_top

sgp15ebbrE27.b1:
  • wdir_vec_mean_mv
  • soil_heat_flow_4_mv
  • soil_moisture_1_rr
  • soil_moisture_3_rr
  • soil_temp_5_rr
  • wspd_arith_mean
  • temp_air_left
  • soil_moisture_5_rr
  • soil_moisture_4_rr
  • temp_reference_rr
  • soil_moisture_2_rr
  • soil_temp_1_rr
  • net_radiation_mv
  • temp_air_right
  • temp_trh_left_rr
  • soil_heat_flow_2_mv
  • atmos_pressure_mv
  • soil_heat_flow_1_mv
  • soil_temp_3_rr
  • home_signal
  • soil_heat_flow_3_mv
  • temp_trh_right_rr
  • soil_heat_flow_5_mv
  • rh_right_mv
  • soil_temp_4_rr
  • soil_temp_2_rr
  • rh_left_mv

sgp30ebbrE27.b1:
  • soil_heat_flow_1
  • surface_soil_heat_flux_2
  • soil_heat_flow_2
  • surface_soil_heat_flux_3
  • surface_soil_heat_flux_4
  • surface_soil_heat_flux_5
  • soil_heat_flow_5
  • soil_heat_flow_3
  • soil_heat_flow_4
  • energy_storage_change_3
  • energy_storage_change_4
  • energy_storage_change_5
  • energy_storage_change_1
  • energy_storage_change_2
  • rh_bottom_fraction
  • rh_top_fraction
  • surface_soil_heat_flux_1
  • corr_soil_heat_flow_1
  • temp_air_top
  • sensible_heat_flux
  • Barometric Pressure(atmos_pressure)
  • wdir_vec_mean
  • wspd_arith_mean
  • temp_air_bottom
  • temp_trh_bottom
  • temp_trh_top
  • wspd_vec_mean
  • corr_soil_heat_flow_2
  • vapor_pressure_bottom
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_4
  • corr_soil_heat_flow_5
  • latent_heat_flux
  • net_radiation
  • home_signal_30
  • soil_moisture_1
  • soil_temp_1
  • soil_moisture_2
  • soil_temp_4
  • soil_moisture_3
  • soil_temp_5
  • soil_moisture_4
  • soil_temp_2
  • soil_moisture_5
  • soil_temp_3
  • vapor_pressure_top
  • soil_heat_capacity_5
  • soil_heat_capacity_3
  • soil_heat_capacity_4
  • wdir_vec_std
  • home_signal_15
  • surface_soil_heat_flux_avg
  • temp_reference
  • soil_heat_capacity_2
  • soil_heat_capacity_1
  • bowen_ratio


Back To Table of Contents

DQRID : D060818.11
Start DateStart TimeEnd DateEnd Time
04/26/2006183008/17/20061730
Subject:
SGP/EBBR/E27 - Most Measurements Suspect
DataStreams:sgp15ebbrE27.b1, sgp30ebbrE27.b1, sgp5ebbrE27.b1
Description:
The wrong EBBR program was used at this site.  Therefore, most of the measurements are 
suspect.

Note: Mentor reports reprocessing will not correct this problem.
Measurements:sgp5ebbrE27.b1:
  • rh_top_fraction
  • base time(base_time)
  • temp_reference
  • vapor_pressure_bottom
  • lon(lon)
  • temp_trh_bottom
  • temp_air_bottom
  • home_signal
  • time(time)
  • wspd_vec_mean
  • lat(lat)
  • wdir_vec_std
  • wspd_arith_mean
  • rh_bottom_fraction
  • temp_air_top
  • wdir_vec_mean
  • net_radiation
  • Barometric Pressure(atmos_pressure)
  • Dummy altitude for Zeb(alt)
  • Time offset of tweaks from base_time(time_offset)
  • vapor_pressure_top
  • temp_trh_top

sgp15ebbrE27.b1:
  • wdir_vec_mean_mv
  • soil_heat_flow_4_mv
  • lon(lon)
  • soil_moisture_1_rr
  • soil_moisture_3_rr
  • battery_voltage
  • Time offset of tweaks from base_time(time_offset)
  • soil_temp_5_rr
  • wspd_arith_mean
  • Dummy altitude for Zeb(alt)
  • temp_air_left
  • soil_moisture_5_rr
  • soil_moisture_4_rr
  • temp_reference_rr
  • soil_moisture_2_rr
  • soil_temp_1_rr
  • net_radiation_mv
  • lat(lat)
  • temp_air_right
  • temp_trh_left_rr
  • soil_heat_flow_2_mv
  • atmos_pressure_mv
  • soil_heat_flow_1_mv
  • soil_temp_3_rr
  • home_signal
  • soil_heat_flow_3_mv
  • temp_trh_right_rr
  • soil_heat_flow_5_mv
  • rh_right_mv
  • base time(base_time)
  • soil_temp_4_rr
  • soil_temp_2_rr
  • rh_left_mv

sgp30ebbrE27.b1:
  • surface_soil_heat_flux_2
  • soil_heat_flow_1
  • surface_soil_heat_flux_3
  • soil_heat_flow_2
  • surface_soil_heat_flux_4
  • surface_soil_heat_flux_5
  • soil_heat_flow_5
  • soil_heat_flow_3
  • soil_heat_flow_4
  • energy_storage_change_3
  • energy_storage_change_4
  • energy_storage_change_5
  • energy_storage_change_1
  • energy_storage_change_2
  • rh_bottom_fraction
  • rh_top_fraction
  • surface_soil_heat_flux_1
  • corr_soil_heat_flow_1
  • Time offset of tweaks from base_time(time_offset)
  • temp_air_top
  • sensible_heat_flux
  • lon(lon)
  • Barometric Pressure(atmos_pressure)
  • wdir_vec_mean
  • wspd_arith_mean
  • temp_air_bottom
  • temp_trh_bottom
  • temp_trh_top
  • wspd_vec_mean
  • vapor_pressure_bottom
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_4
  • corr_soil_heat_flow_5
  • latent_heat_flux
  • net_radiation
  • home_signal_30
  • soil_moisture_1
  • soil_temp_1
  • soil_temp_4
  • soil_moisture_2
  • soil_temp_5
  • soil_moisture_3
  • soil_temp_2
  • soil_moisture_4
  • soil_temp_3
  • soil_moisture_5
  • base time(base_time)
  • vapor_pressure_top
  • soil_heat_capacity_5
  • soil_heat_capacity_3
  • soil_heat_capacity_4
  • lat(lat)
  • Dummy altitude for Zeb(alt)
  • wdir_vec_std
  • home_signal_15
  • surface_soil_heat_flux_avg
  • temp_reference
  • soil_heat_capacity_2
  • soil_heat_capacity_1
  • bowen_ratio


Back To Table of Contents

DQRID : D060818.13
Start DateStart TimeEnd DateEnd Time
08/11/2006130008/21/20062330
Subject:
SGP/EBBR/E27 - Battery Voltage Problem - Measurements Incorrect
DataStreams:sgp15ebbrE27.b1, sgp30ebbrE27.b1, sgp5ebbrE27.b1
Description:
Battery voltage was too low much of the time during the period, thus most measurements 
were incorrect during much of the time period.
Measurements:sgp5ebbrE27.b1:
  • rh_top_fraction
  • temp_reference
  • vapor_pressure_bottom
  • temp_trh_bottom
  • temp_air_bottom
  • home_signal
  • wspd_vec_mean
  • wdir_vec_std
  • wspd_arith_mean
  • rh_bottom_fraction
  • temp_air_top
  • wdir_vec_mean
  • net_radiation
  • Barometric Pressure(atmos_pressure)
  • vapor_pressure_top
  • temp_trh_top

sgp15ebbrE27.b1:
  • wdir_vec_mean_mv
  • soil_heat_flow_4_mv
  • soil_moisture_1_rr
  • soil_moisture_3_rr
  • soil_temp_5_rr
  • wspd_arith_mean
  • temp_air_left
  • soil_moisture_5_rr
  • soil_moisture_4_rr
  • temp_reference_rr
  • soil_moisture_2_rr
  • soil_temp_1_rr
  • net_radiation_mv
  • temp_air_right
  • temp_trh_left_rr
  • soil_heat_flow_2_mv
  • atmos_pressure_mv
  • soil_heat_flow_1_mv
  • soil_temp_3_rr
  • home_signal
  • soil_heat_flow_3_mv
  • temp_trh_right_rr
  • soil_heat_flow_5_mv
  • rh_right_mv
  • soil_temp_4_rr
  • soil_temp_2_rr
  • rh_left_mv

sgp30ebbrE27.b1:
  • soil_heat_flow_1
  • surface_soil_heat_flux_2
  • soil_heat_flow_2
  • surface_soil_heat_flux_3
  • surface_soil_heat_flux_4
  • surface_soil_heat_flux_5
  • soil_heat_flow_5
  • soil_heat_flow_3
  • soil_heat_flow_4
  • energy_storage_change_3
  • energy_storage_change_4
  • energy_storage_change_5
  • energy_storage_change_1
  • energy_storage_change_2
  • rh_bottom_fraction
  • rh_top_fraction
  • surface_soil_heat_flux_1
  • corr_soil_heat_flow_1
  • temp_air_top
  • sensible_heat_flux
  • Barometric Pressure(atmos_pressure)
  • wdir_vec_mean
  • wspd_arith_mean
  • temp_air_bottom
  • temp_trh_bottom
  • temp_trh_top
  • wspd_vec_mean
  • corr_soil_heat_flow_2
  • vapor_pressure_bottom
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_4
  • corr_soil_heat_flow_5
  • latent_heat_flux
  • net_radiation
  • home_signal_30
  • soil_moisture_1
  • soil_temp_1
  • soil_moisture_2
  • soil_temp_4
  • soil_moisture_3
  • soil_temp_5
  • soil_moisture_4
  • soil_temp_2
  • soil_moisture_5
  • soil_temp_3
  • vapor_pressure_top
  • soil_heat_capacity_5
  • soil_heat_capacity_3
  • soil_heat_capacity_4
  • wdir_vec_std
  • home_signal_15
  • surface_soil_heat_flux_avg
  • temp_reference
  • soil_heat_capacity_2
  • soil_heat_capacity_1
  • bowen_ratio


Back To Table of Contents

DQRID : D060921.8
Start DateStart TimeEnd DateEnd Time
08/21/2006063008/30/20061800
Subject:
SGP/EBBR/E22 - Net Radiation and Sensible and Latent Heat Fluxes Incorrect
DataStreams:sgp15ebbrE22.b1, sgp30ebbrE22.b1, sgp5ebbrE22.b1
Description:
Rain entered the net radiometer, causing net radiation, and thus sensible and latent heat 
fluxes, to be too large.
Measurements:sgp30ebbrE22.b1:
  • latent_heat_flux
  • sensible_heat_flux
  • net_radiation

sgp5ebbrE22.b1:
  • net_radiation

sgp15ebbrE22.b1:
  • net_radiation_mv


Back To Table of Contents

DQRID : D061106.5
Start DateStart TimeEnd DateEnd Time
09/16/2006000011/08/20061940
Subject:
SGP/EBBR/E22 - Soil Heat Flow #4 Incorrect - Sensible and Latent Heat Fluxes Sometimes 
Affected
DataStreams:sgp15ebbrE22.b1, sgp30ebbrE22.b1
Description:
Soil heat flow sensor #4 dropped to low values or offscale.

Sensible and latent heat fluxes were sometimes affected.
Measurements:sgp30ebbrE22.b1:
  • latent_heat_flux
  • sensible_heat_flux
  • corr_soil_heat_flow_4
  • soil_heat_flow_4
  • surface_soil_heat_flux_avg
  • surface_soil_heat_flux_4

sgp15ebbrE22.b1:
  • soil_heat_flow_4_mv


Back To Table of Contents

DQRID : D070426.1
Start DateStart TimeEnd DateEnd Time
04/16/2007040004/26/20071630
Subject:
SGP/EBBR/E22 - Wind Direction Incorrect
DataStreams:sgp15ebbrE22.b1, sgp30ebbrE22.b1, sgp5ebbrE22.b1
Description:
Wind direction was flat-lining at 135 degrees and occasionally changed to 0.4 degrees.
Measurements:sgp30ebbrE22.b1:
  • wspd_vec_mean
  • wdir_vec_mean
  • wdir_vec_std

sgp5ebbrE22.b1:
  • wdir_vec_std
  • wdir_vec_mean
  • wspd_vec_mean

sgp15ebbrE22.b1:
  • wdir_vec_mean_mv


Back To Table of Contents

DQRID : D070716.2
Start DateStart TimeEnd DateEnd Time
07/10/2007150009/12/20072045
Subject:
SGP/EBBR/E20 - Reprocess: Wind Direction 20 Degrees Low
DataStreams:sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1
Description:
The EBBR wind direction was found to be misaligned 20 degrees low. 

This bias should have had no effect on the res_ws or sigma_wd measurements.
Measurements:sgp5ebbrE20.b1:
  • wdir_vec_mean

sgp15ebbrE20.b1:
  • wdir_vec_mean_mv

sgp30ebbrE20.b1:
  • wdir_vec_mean


Back To Table of Contents

DQRID : D070809.1
Start DateStart TimeEnd DateEnd Time
08/07/2007213008/13/20071600
08/19/2007130008/29/20072130
Subject:
SGP/EBBR/E27 - Multiplexer #2 failure
DataStreams:sgp15ebbrE27.b1, sgp30ebbrE27.b1, sgp5ebbrE27.b1
Description:
A problem with the #2 Multiplexer caused a large number of measurements to be incorrect.  
Sensible and latent heat fluxes were often affected.
Measurements:sgp5ebbrE27.b1:
  • rh_top_fraction
  • rh_bottom_fraction
  • vapor_pressure_bottom
  • temp_air_bottom
  • temp_air_top
  • net_radiation
  • home_signal
  • Barometric Pressure(atmos_pressure)
  • vapor_pressure_top

sgp15ebbrE27.b1:
  • soil_heat_flow_2_mv
  • atmos_pressure_mv
  • soil_heat_flow_4_mv
  • soil_heat_flow_1_mv
  • temp_air_left
  • home_signal
  • soil_heat_flow_3_mv
  • soil_heat_flow_5_mv
  • rh_right_mv
  • net_radiation_mv
  • temp_air_right
  • rh_left_mv

sgp30ebbrE27.b1:
  • latent_heat_flux
  • soil_heat_flow_1
  • surface_soil_heat_flux_2
  • soil_heat_flow_2
  • surface_soil_heat_flux_3
  • surface_soil_heat_flux_4
  • surface_soil_heat_flux_5
  • soil_heat_flow_5
  • soil_heat_flow_3
  • soil_heat_flow_4
  • net_radiation
  • home_signal_30
  • rh_bottom_fraction
  • rh_top_fraction
  • surface_soil_heat_flux_1
  • vapor_pressure_top
  • corr_soil_heat_flow_1
  • temp_air_top
  • sensible_heat_flux
  • home_signal_15
  • temp_air_bottom
  • surface_soil_heat_flux_avg
  • bowen_ratio
  • corr_soil_heat_flow_2
  • vapor_pressure_bottom
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_4
  • corr_soil_heat_flow_5


Back To Table of Contents

DQRID : D070815.6
Start DateStart TimeEnd DateEnd Time
07/20/2007063008/01/20072200
Subject:
SGP/EBBR/E22 - H and LE Incorrect
DataStreams:sgp15ebbrE22.b1, sgp30ebbrE22.b1
Description:
Soil Heat Flow 1 bounced around and went offscale at times, resulting in the EBBR program 
setting sensible and latent heat fluxes to 9999es.

The problem ended during a PM visit, possibly because of routine checks and tightening of 
leads in terminal strips.
Measurements:sgp30ebbrE22.b1:
  • latent_heat_flux
  • sensible_heat_flux
  • corr_soil_heat_flow_1
  • soil_heat_flow_1
  • surface_soil_heat_flux_1
  • surface_soil_heat_flux_avg

sgp15ebbrE22.b1:
  • soil_heat_flow_1_mv


Back To Table of Contents

DQRID : D071001.1
Start DateStart TimeEnd DateEnd Time
09/28/2007014010/11/20071730
Subject:
SGP/EBBR/E26 - Sensible and Latent Heat Fluxes Affected by bad temp sensor
DataStreams:sgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
Description:
The left Thum (temperature of the humidity sensor chamber) measurement was incorrect at 
times, affecting several measurements, including the sensible and latent heat fluxes.
Measurements:sgp30ebbrE26.b1:
  • vapor_pressure_bottom
  • temp_trh_top
  • bowen_ratio
  • latent_heat_flux
  • temp_trh_bottom
  • vapor_pressure_top
  • sensible_heat_flux

sgp15ebbrE26.b1:
  • temp_trh_left_rr

sgp5ebbrE26.b1:
  • temp_trh_top
  • temp_trh_bottom
  • vapor_pressure_bottom
  • vapor_pressure_top


Back To Table of Contents

DQRID : D071115.1
Start DateStart TimeEnd DateEnd Time
10/15/2007000010/24/20071900
Subject:
SGP/EBBR/E20 - Reprocess: Wind Direction 65 Degrees Low
DataStreams:sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1
Description:
The wind direction sensor reported wind directions that were 65 degrees too low because of 
a mis-alignment.

This bias should have no effect on the res_ws or sigma_wd measurements.

The wind direction data could be re-processed by adding 65 degrees.
Measurements:sgp5ebbrE20.b1:
  • wdir_vec_mean

sgp15ebbrE20.b1:
  • wdir_vec_mean_mv

sgp30ebbrE20.b1:
  • wdir_vec_mean


Back To Table of Contents

DQRID : D080114.3
Start DateStart TimeEnd DateEnd Time
12/22/2007180003/26/20081730
Subject:
SGP/EBBR/E27 - Measurements offscale
DataStreams:sgp15ebbrE27.b1, sgp30ebbrE27.b1, sgp5ebbrE27.b1
Description:
All J-panel 4 measurements (soil heat flows, net radiation, air temperatures, home 
signals, pressure, vapor pressure) were sometimes offscale or otherwise incorrect.  J-Panel was 
replaced 20080326 correcting the problem.
Measurements:sgp5ebbrE27.b1:
  • temp_air_bottom
  • temp_air_top
  • net_radiation
  • home_signal
  • Barometric Pressure(atmos_pressure)
  • vapor_pressure_top
  • vapor_pressure_bottom

sgp15ebbrE27.b1:
  • soil_heat_flow_2_mv
  • home_signal
  • soil_heat_flow_3_mv
  • soil_heat_flow_5_mv
  • soil_heat_flow_4_mv
  • atmos_pressure_mv
  • net_radiation_mv
  • temp_air_right
  • soil_heat_flow_1_mv
  • temp_air_left

sgp30ebbrE27.b1:
  • corr_soil_heat_flow_1
  • latent_heat_flux
  • surface_soil_heat_flux_2
  • soil_heat_flow_1
  • surface_soil_heat_flux_3
  • soil_heat_flow_2
  • surface_soil_heat_flux_4
  • surface_soil_heat_flux_5
  • soil_heat_flow_5
  • soil_heat_flow_3
  • soil_heat_flow_4
  • net_radiation
  • temp_air_top
  • sensible_heat_flux
  • home_signal_30
  • Barometric Pressure(atmos_pressure)
  • home_signal_15
  • temp_air_bottom
  • surface_soil_heat_flux_1
  • vapor_pressure_top
  • vapor_pressure_bottom
  • corr_soil_heat_flow_2
  • corr_soil_heat_flow_3
  • corr_soil_heat_flow_4
  • corr_soil_heat_flow_5


Back To Table of Contents

DQRID : D080410.2
Start DateStart TimeEnd DateEnd Time
04/08/2008060005/07/20082000
Subject:
SGP/EBBR/E20 - Wind Direction 50 Degrees High
DataStreams:sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1
Description:
The wind direction was offset high about 50 degrees.
Measurements:sgp5ebbrE20.b1:
  • wdir_vec_mean

sgp15ebbrE20.b1:
  • wdir_vec_mean_mv

sgp30ebbrE20.b1:
  • wdir_vec_mean


Back To Table of Contents

DQRID : D080902.1
Start DateStart TimeEnd DateEnd Time
08/15/2008023009/10/20082230
Subject:
SGP/EBBR/E20 - Wind Direction Incorrect
DataStreams:sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1
Description:
The wind direction differed from the co-located SMOS by 50 deg during part of the stated 
period and the electronics had failed completely resulting in a constant 135 degrees for 
the following dates and times:
08/15 0230-0430, 0830-1530 and 09/03 0200-0300, 0500 - 09/10 2230.

Sensible and latent heat fluxes were not affected by this problem.
Measurements:sgp5ebbrE20.b1:
  • wspd_vec_mean
  • wdir_vec_mean
  • wdir_vec_std

sgp15ebbrE20.b1:
  • wdir_vec_mean_mv

sgp30ebbrE20.b1:
  • wdir_vec_mean
  • wdir_vec_std
  • wspd_vec_mean


Back To Table of Contents

DQRID : D090313.16
Start DateStart TimeEnd DateEnd Time
01/26/2009191001/27/20090800
Subject:
SGP/EBBR/E20 - Wind Speed Incorrect
DataStreams:sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1
Description:
The wind speed sensor was frozen stopped by freezing rain.
Measurements:sgp5ebbrE20.b1:
  • wspd_vec_mean
  • wspd_arith_mean

sgp15ebbrE20.b1:
  • wspd_arith_mean

sgp30ebbrE20.b1:
  • wspd_arith_mean
  • wspd_vec_mean


Back To Table of Contents

DQRID : D090313.6
Start DateStart TimeEnd DateEnd Time
01/26/2009184501/28/20091810
Subject:
SGP/EBBR/E22 - Wind Speed Incorrect
DataStreams:sgp15ebbrE22.b1, sgp30ebbrE22.b1, sgp5ebbrE22.b1
Description:
The wind speed sensor was frozen stopped by freezing rain.
Measurements:sgp30ebbrE22.b1:
  • wspd_vec_mean
  • wspd_arith_mean

sgp5ebbrE22.b1:
  • wspd_vec_mean
  • wspd_arith_mean

sgp15ebbrE22.b1:
  • wspd_arith_mean


Back To Table of Contents

DQRID : D090313.8
Start DateStart TimeEnd DateEnd Time
01/26/2009180501/28/20091955
Subject:
SGP/EBBR/E26 - Wind Speed Incorrect
DataStreams:sgp15ebbrE26.b1, sgp30ebbrE26.b1, sgp5ebbrE26.b1
Description:
The wind speed sensor was frozen stopped by freezing rain.
Measurements:sgp30ebbrE26.b1:
  • wspd_arith_mean
  • wspd_vec_mean

sgp15ebbrE26.b1:
  • wspd_arith_mean

sgp5ebbrE26.b1:
  • wspd_arith_mean
  • wspd_vec_mean


Back To Table of Contents

DQRID : D090313.9
Start DateStart TimeEnd DateEnd Time
01/26/2009180001/28/20092145
Subject:
SGP/EBBR/E27 - Wind Speed Incorrect
DataStreams:sgp15ebbrE27.b1, sgp30ebbrE27.b1, sgp5ebbrE27.b1
Description:
The wind speed sensor was frozen stopped by freezing rain.
Measurements:sgp5ebbrE27.b1:
  • wspd_arith_mean
  • wspd_vec_mean

sgp15ebbrE27.b1:
  • wspd_arith_mean

sgp30ebbrE27.b1:
  • wspd_arith_mean
  • wspd_vec_mean


Back To Table of Contents

DQRID : D090414.1
Start DateStart TimeEnd DateEnd Time
04/12/2009030504/22/20091400
Subject:
SGP/EBBR/E20 - Wind Direction Incorrect
DataStreams:sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1
Description:
The wind direction measurement was stuck at 40 degrees.
Measurements:sgp5ebbrE20.b1:
  • wdir_vec_mean
  • wdir_vec_std

sgp15ebbrE20.b1:
  • wdir_vec_mean_mv

sgp30ebbrE20.b1:
  • wdir_vec_mean
  • wdir_vec_std


Back To Table of Contents