Data Quality Reports for Session: 133205 User: roj Completed: 02/12/2011


TABLE OF CONTENTS

DQR IDSubjectData Streams Affected
D050310.3TWP/MWR/C2 - Heater problemtwpmwrlosC2.b1, twpmwrtipC2.a1, twp5mwravgC2.c1
D050524.2TWP/MWR/C2 - mixer temperaturetwpmwrlosC2.b1, twpmwrtipC2.a1
D050725.10TWP/MWR/C2 - Reprocessed: Revised Retrieval CoefficientstwpmwrlosC2.b1, twp5mwravgC2.c1, twpqmemwrcolC2.c1
D050928.2TWP/MWR/C2 - New software version (4.15) installedtwpmwrlosC2.b1, twpmwrtipC2.a1
D061002.1TWP/MWR/C2 - Missing datatwpmwrC2.00, twpmwrlosC2.b1, twpmwrtipC2.a1, twp5mwravgC2.c1
D061121.1TWP/MWR/C2 - Missing DatatwpmwrlosC2.b1
D061213.3TWP/MWR/C2 - Reprocessed: New Calibration coefficientstwpmwrlosC2.b1, twpmwrtipC2.a1
D070412.3TWP/MWR/C1/C2 - Sun in the field of viewtwpmwrlosC1.b1, twpmwrlosC2.b1, twpmwrtipC1.a1, twpmwrtipC2.a1
D081216.1TWP/MWR/C2 - Incorrect ambient temperature during raintwpmwrlosC2.b1, twpmwrtipC2.a1
D090417.3TWP/MWR/C2 - Intermittent datatwpmwrlosC2.b1, twpmwrtipC2.a1


DQRID : D050310.3
Start DateStart TimeEnd DateEnd Time
02/04/2005234003/14/20051650
Subject:
TWP/MWR/C2 - Heater problem
DataStreams:twpmwrlosC2.b1, twpmwrtipC2.a1, twp5mwravgC2.c1
Description:
When the wiring of the air temperature sensor was checked the heater apparently began 
activating too often.
Measurements:twpmwrtipC2.a1:
  • wet_window

twp5mwravgC2.c1:
  • water_flag_fraction

twpmwrlosC2.b1:
  • wet_window


Back To Table of Contents

DQRID : D050524.2
Start DateStart TimeEnd DateEnd Time
02/04/2005234004/19/20050242
Subject:
TWP/MWR/C2 - mixer temperature
DataStreams:twpmwrlosC2.b1, twpmwrtipC2.a1
Description:
When the wiring of the air temperature sensor was checked the mixer temperature 
unexpectedly decreased 4 degrees. It increased to its normal value when the dielectric window was 
replaced. The problem was probably caused by a loose and/or corroded connection.
Measurements:twpmwrtipC2.a1:
  • tkxc

twpmwrlosC2.b1:
  • tkxc


Back To Table of Contents

DQRID : D050725.10
Start DateStart TimeEnd DateEnd Time
04/27/2002060006/30/20052100
Subject:
TWP/MWR/C2 - Reprocessed: Revised Retrieval Coefficients
DataStreams:twpmwrlosC2.b1, twp5mwravgC2.c1, twpqmemwrcolC2.c1
Description:
IN THE BEGINNING (June 1992), the retrieval coefficients used to derive the precipitable 
water vapor (PWV) and liquid water path (LWP) from the MWR brightness temperatures were 
based on the Liebe and Layton (1987) water vapor and oxygen absorption model and the Grant 
(1957) liquid water absorption model.

Following the SHEBA experience, revised retrievals based on the more recent Rosenkranz 
(1998) water vapor and oxygen absorption models and the Liebe (1991) liquid waer absorption 
model were developed.  The Rosenkranz water vapor absorption model resulted a 2 percent 
increase in PWV relative to the earlier Liebe and Layton model.  The Liebe liquid water 
absorption model decreased the LWP by 10% relative to the Grant model.  However, the 
increased oxygen absorption caused a 0.02-0.03 mm (20-30 g/m2) reduction in LWP, which was 
particularly significant for low LWP conditions (i.e. thin clouds encountered at SHEBA).

Recently, it has been shown (Liljegren, Boukabara, Cady-Pereira, and Clough, TGARS v. 43, 
pp 1102-1108, 2005) that the half-width of the 22 GHz water vapor line from the HITRAN 
compilation, which is 5 percent smaller than the Liebe and Dillon (1969) half-width used in 
Rosenkranz (1998), provided a better fit to the microwave brightness temperature 
measurements at 5 frequencies in the range 22-30 GHz, and yielded more accurate retrievals. 
Accordingly, revised MWR retrieval coefficients have been developed using MONORTM, which 
utilizes the HITRAN compilation for its spectroscopic parameters.  These new retrievals 
provide 3 percent less PWV and 2.6 percent greater LWP than the previous 
retrievals based on Rosenkranz (1998).

The Rosenkranz-based retrieval coefficients became active at TWP.C2 20020427.0600.  The 
MONORTM-based retrieval coefficients became active at TWP.C2 20050630.2100.

Note: The TWP.C2 data for 19981028-20050630 have been reprocessed to apply the 
MONORTM-based retrievals for all time.  The reprocessed data were archived 20061003.
Measurements:twpqmemwrcolC2.c1:
  • mean_vap_mwr
  • mean_liq_mwr

twp5mwravgC2.c1:
  • Total liquid water along LOS path(liq)
  • Total water vapor along LOS path(vap)

twpmwrlosC2.b1:
  • Total liquid water along LOS path(liq)
  • Total water vapor along LOS path(vap)


Back To Table of Contents

DQRID : D050928.2
Start DateStart TimeEnd DateEnd Time
11/01/2002210109/15/20051424
Subject:
TWP/MWR/C2 - New software version (4.15) installed
DataStreams:twpmwrlosC2.b1, twpmwrtipC2.a1
Description:
A problem began with the installation of MWR.EXE version 4.12 in November 2002. The 
software had been upgraded from a "DOS" to a "Windows"-compiled program to address an earlier 
problem.  The software upgrade corrected the earlier problem but introduced a new one that 
caused line-of-sight observing cycles to be skipped, a 15% reduction in the number of 
tip curves, and saturation of CPU usage.  Software versions 4.13 and 4.14 also produced 
these problems.

The new MWR software version (4.15) was installed on 9/15/2005. As a consequence of this 
upgrade, the tip curve frequency increased. The tip cycle time decreased from ~60s to ~50s.
Measurements:twpmwrtipC2.a1:
  • tipsky23
  • bbn31
  • tkair
  • tkbb
  • tnd_nom31
  • tkxc
  • tnd31
  • bbn23
  • tc31
  • r23
  • tknd
  • tnd23I
  • bb31
  • tc23
  • tnd_nom23
  • tnd23
  • tnd31I
  • r31
  • tipsky31

twpmwrlosC2.b1:
  • tnd_nom23
  • Temperature, Sky Infra-Red(sky_ir_temp)
  • tnd23
  • sky23
  • Total liquid water along LOS path(liq)
  • bbn23
  • bb31
  • Temperature, brightness, longwave(ir_temp)
  • tkbb
  • tc23
  • Radiation, longwave, brightness temperature, 23.8 GHz(tbsky23)
  • 31.4 GHz sky brightness temperature(tbsky31)
  • sky31
  • tnd_nom31
  • tkxc
  • tkair
  • Total water vapor along LOS path(vap)
  • tknd
  • tnd31
  • bb23
  • bbn31
  • tc31


Back To Table of Contents

DQRID : D061002.1
Start DateStart TimeEnd DateEnd Time
09/14/2006150011/27/20061900
Subject:
TWP/MWR/C2 - Missing data
DataStreams:twpmwrC2.00, twpmwrlosC2.b1, twpmwrtipC2.a1, twp5mwravgC2.c1
Description:
The heater blower assembly was causing the fuse to blow.  The instrument was taken offline 
until a replacement arrives.
Measurements:twpmwrtipC2.a1:
  • tipsky23
  • tkair
  • base_time
  • tnd_nom31
  • tkxc
  • actaz
  • wet_window
  • r23
  • tnd23I
  • tc23
  • time_offset
  • tnd_nom23
  • tnd23
  • lat
  • r31
  • bb23
  • bbn31
  • tkbb
  • bbn23
  • tnd31
  • tc31
  • tknd
  • alt
  • bb31
  • actel
  • tnd31I
  • lon
  • tipsky31

twp5mwravgC2.c1:
  • tbsky31_sdev
  • Total liquid water along LOS path(liq)
  • time_offset
  • lat
  • vap_sdev
  • ir_temp_sdev
  • Temperature, brightness, longwave(ir_temp)
  • base_time
  • Radiation, longwave, brightness temperature, 23.8 GHz(tbsky23)
  • tbsky23_sdev
  • alt
  • water_flag_fraction
  • lon
  • 31.4 GHz sky brightness temperature(tbsky31)
  • liq_sdev
  • num_obs
  • num_obs_irt
  • Total water vapor along LOS path(vap)

twpmwrC2.00:
  • Raw data stream - documentation not supported

twpmwrlosC2.b1:
  • tnd23
  • sky23
  • Total liquid water along LOS path(liq)
  • bbn23
  • tkbb
  • tc23
  • tkxc
  • tnd31
  • bbn31
  • base_time
  • tnd_nom23
  • Temperature, Sky Infra-Red(sky_ir_temp)
  • lat
  • lon
  • time_offset
  • bb31
  • Temperature, brightness, longwave(ir_temp)
  • actel
  • wet_window
  • Radiation, longwave, brightness temperature, 23.8 GHz(tbsky23)
  • 31.4 GHz sky brightness temperature(tbsky31)
  • sky31
  • tnd_nom31
  • tkair
  • tknd
  • Total water vapor along LOS path(vap)
  • bb23
  • alt
  • tc31
  • actaz


Back To Table of Contents

DQRID : D061121.1
Start DateStart TimeEnd DateEnd Time
11/02/1998211211/06/19982140
07/02/2000200007/04/20000047
02/09/2002230002/11/20022300
01/23/2004110001/27/20041957
05/27/2005114305/29/20052132
Subject:
TWP/MWR/C2 - Missing Data
DataStreams:twpmwrlosC2.b1
Description:
Data are missing and unrecoverable.
Measurements:twpmwrlosC2.b1:
  • tnd_nom23
  • Temperature, Sky Infra-Red(sky_ir_temp)
  • tnd23
  • lat
  • sky23
  • Total liquid water along LOS path(liq)
  • lon
  • bbn23
  • time_offset
  • bb31
  • Temperature, brightness, longwave(ir_temp)
  • actel
  • wet_window
  • tkbb
  • tc23
  • Radiation, longwave, brightness temperature, 23.8 GHz(tbsky23)
  • sky31
  • 31.4 GHz sky brightness temperature(tbsky31)
  • tnd_nom31
  • tkxc
  • tkair
  • tknd
  • Total water vapor along LOS path(vap)
  • bb23
  • tnd31
  • bbn31
  • alt
  • tc31
  • actaz
  • base_time


Back To Table of Contents

DQRID : D061213.3
Start DateStart TimeEnd DateEnd Time
11/27/2006190011/30/20060700
Subject:
TWP/MWR/C2 - Reprocessed: New Calibration coefficients
DataStreams:twpmwrlosC2.b1, twpmwrtipC2.a1
Description:
On 11/27 a spare radiometer was installed to replace a faulty radiometer. Once the 
radiometer started to collect data it used the default calibration coefficients until it 
collected enough tip data to determine its own coefficients.

The data were reprocessed to apply corrected calibrations and the reprocessed data were 
archived 20061222.
Measurements:twpmwrtipC2.a1:
  • tc23
  • tnd_nom23
  • tnd_nom31
  • tnd23
  • tnd31
  • tc31

twpmwrlosC2.b1:
  • tnd_nom23
  • tnd23
  • 31.4 GHz sky brightness temperature(tbsky31)
  • tnd_nom31
  • Total liquid water along LOS path(liq)
  • Total water vapor along LOS path(vap)
  • tnd31
  • tc31
  • tc23
  • Radiation, longwave, brightness temperature, 23.8 GHz(tbsky23)


Back To Table of Contents

DQRID : D070412.3
Start DateStart TimeEnd DateEnd Time
03/07/2007000004/02/20072359
03/01/2008000004/02/20082359
09/10/2008000010/12/20080000
03/01/2009000004/02/20092359
09/11/2009000010/10/20092359
03/01/2010000004/02/20102359
Subject:
TWP/MWR/C1/C2 - Sun in the field of view
DataStreams:twpmwrlosC1.b1, twpmwrlosC2.b1, twpmwrtipC1.a1, twpmwrtipC2.a1
Description:
Every day between around noon local time (usually between 1 and 2 AM UTC time) there is an 
increase in the brightness temperatures due to the sun in the field of view of the 
radiometer.

The effect lasts less than an hour around local noon (usually between 1 and 2 AM UTC 
time).  The effect appears as a smooth increase and decrease in brightness temperature.
Measurements:twpmwrtipC2.a1:
  • tipsky23
  • tipsky31

twpmwrtipC1.a1:
  • vaptip
  • liqtip
  • tbskytip23
  • tbskytip31

twpmwrlosC1.b1:
  • Total liquid water along LOS path(liq)
  • sky23
  • 31.4 GHz sky brightness temperature(tbsky31)
  • sky31
  • Total water vapor along LOS path(vap)
  • Radiation, longwave, brightness temperature, 23.8 GHz(tbsky23)

twpmwrlosC2.b1:
  • 31.4 GHz sky brightness temperature(tbsky31)
  • sky31
  • sky23
  • Total liquid water along LOS path(liq)
  • Total water vapor along LOS path(vap)
  • Radiation, longwave, brightness temperature, 23.8 GHz(tbsky23)


Back To Table of Contents

DQRID : D081216.1
Start DateStart TimeEnd DateEnd Time
10/09/2008010001/09/20090300
Subject:
TWP/MWR/C2 - Incorrect ambient temperature during rain
DataStreams:twpmwrlosC2.b1, twpmwrtipC2.a1
Description:
The ambient temperature was approximately 15 degree higher than what it should be when it 
was raining and the heater came. On Jan 9 2009 the dewblower was replaced which solved 
the problem.

The increased ambient temperature (tkair) was happening during times of rain and users 
should always disregard MWR data during rain events.  Therefore this DQR is colored 
transparent.
Measurements:twpmwrtipC2.a1:
  • tkair

twpmwrlosC2.b1:
  • tkair


Back To Table of Contents

DQRID : D090417.3
Start DateStart TimeEnd DateEnd Time
03/06/2009160003/14/20092200
Subject:
TWP/MWR/C2 - Intermittent data
DataStreams:twpmwrlosC2.b1, twpmwrtipC2.a1
Description:
There are several short data gaps (usually 2 to 7 hours) in the data due to computer 
malfunction. The problem was solved by replacing the computer.
Measurements:twpmwrtipC2.a1:
  • tipsky23
  • tkair
  • base_time
  • tnd_nom31
  • tkxc
  • actaz
  • wet_window
  • r23
  • tnd23I
  • tc23
  • time_offset
  • tnd_nom23
  • tnd23
  • lat
  • r31
  • bb23
  • bbn31
  • tkbb
  • bbn23
  • tnd31
  • tc31
  • tknd
  • alt
  • bb31
  • actel
  • tnd31I
  • lon
  • tipsky31

twpmwrlosC2.b1:
  • tnd23
  • sky23
  • Total liquid water along LOS path(liq)
  • bbn23
  • tkbb
  • tc23
  • tkxc
  • tnd31
  • bbn31
  • base_time
  • tnd_nom23
  • Temperature, Sky Infra-Red(sky_ir_temp)
  • lat
  • lon
  • time_offset
  • bb31
  • Temperature, brightness, longwave(ir_temp)
  • actel
  • wet_window
  • Radiation, longwave, brightness temperature, 23.8 GHz(tbsky23)
  • sky31
  • 31.4 GHz sky brightness temperature(tbsky31)
  • tnd_nom31
  • tkair
  • tknd
  • Total water vapor along LOS path(vap)
  • bb23
  • alt
  • tc31
  • actaz


Back To Table of Contents