Data Quality Reports for Session: 133868 User: gp8 Completed: 03/16/2011


TABLE OF CONTENTS

DQR IDSubjectData Streams Affected
D100727.5SGP/EBBR/E13 - Incorrect Sensible and Latent Heat Fluxessgp5ebbrE13.b1, sgp15ebbrE13.b1, sgp30ebbrE13.b1


DQRID : D100727.5
Start DateStart TimeEnd DateEnd Time
07/06/2010193007/21/20101400
Subject:
SGP/EBBR/E13 - Incorrect Sensible and Latent Heat Fluxes
DataStreams:sgp5ebbrE13.b1, sgp15ebbrE13.b1, sgp30ebbrE13.b1
Description:
The multiplexer to which the air temperatures were connected experienced a problem, 
resulting in incorrect sensible and latent heat fluxes at times.
Measurements:sgp15ebbrE13.b1:
  • temp_air_right
  • temp_air_left

sgp5ebbrE13.b1:
  • temp_air_top
  • temp_air_bottom

sgp30ebbrE13.b1:
  • Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
  • temp_air_bottom
  • bowen_ratio
  • temp_air_top
  • Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)


Back To Table of Contents



END OF DATA