DQR ID | Subject | Data Streams Affected |
---|---|---|
D050412.1 | PYE/MET/M1 - Data questionable | pyesmet60sM1.b1 |
D050811.6 | PYE/SONDE/M1 - Broken RH sensor | pyesondewnpnM1.b1 |
D050823.1 | PYE/SONDE/M1 - Bad temperature and RH | pyesondewnpnM1.b1 |
D050912.3 | PYE/SONDE/M1 - Bad RH sensor | pyesondewnpnM1.b1 |
D050912.4 | PYE/SONDE/M1 - Bad RH sensor | pyesondewnpnM1.b1 |
D080428.8 | PYE/SMET/M1 - Reprocess: ORG Data has very small rainrate values | pyesmet60sM1.b1 |
D081022.10 | PYE/SMET/M1 - Wind Speed data contain offset due to induced voltage | pyesmet60sM1.b1 |
D100216.2 | PYE/VCEIL/M1 - Reprocess: Incorrect serial_number and sum_backscatter fields | pyevceil25kM1.b1 |
Start Date | Start Time | End Date | End Time |
---|---|---|---|
02/11/2005 | 0000 | 03/14/2005 | 2359 |
Subject: | PYE/MET/M1 - Data questionable |
DataStreams: | pyesmet60sM1.b1 |
Description: | During the listed time period, the AMF was in the beginning phase of deployment. Data during this time may not be representative and should be used with caution. |
Measurements: | pyesmet60sM1.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
08/02/2005 | 1129 | 08/02/2005 | 1225 |
Subject: | PYE/SONDE/M1 - Broken RH sensor |
DataStreams: | pyesondewnpnM1.b1 |
Description: | One of the RH sensors on this radiosonde was bad. The RH oscillates rapidly between near 0 and ambient up to approximately 11 km. The near-zero values are incorrect. |
Measurements: | pyesondewnpnM1.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
06/30/2005 | 0528 | 06/30/2005 | 0711 |
Subject: | PYE/SONDE/M1 - Bad temperature and RH |
DataStreams: | pyesondewnpnM1.b1 |
Description: | The temperature appears to be approximately 10 degC too high during the entire sounding. This also causes the RH to be too low. Most likely the problem was a bad temperature sensor. |
Measurements: | pyesondewnpnM1.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
08/31/2005 | 1130 | 08/31/2005 | 1140 |
Subject: | PYE/SONDE/M1 - Bad RH sensor |
DataStreams: | pyesondewnpnM1.b1 |
Description: | The RH sensor heating circuit failed on this sounding. RH values during the first part of the sounding oscillate between a reasonable value and a very low value. It appears that (a) the heating was out of phase, and (b) incorrect values were being reported during the first 10 minutes or so of flight. |
Measurements: | pyesondewnpnM1.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
08/29/2005 | 1128 | 08/29/2005 | 1340 |
Subject: | PYE/SONDE/M1 - Bad RH sensor |
DataStreams: | pyesondewnpnM1.b1 |
Description: | Two problems here - failure of the RH sensor heating circuit and a bad RH sensor. |
Measurements: | pyesondewnpnM1.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
02/01/2005 | 0000 | 09/15/2005 | 2359 |
Subject: | PYE/SMET/M1 - Reprocess: ORG Data has very small rainrate values |
DataStreams: | pyesmet60sM1.b1 |
Description: | The ORG data is collected via analog signal and not digital. Therefore, we continuously collect data even when no rain is occurring. We also capture small events such as leaves, large bugs, dust, etc blowing through the measurement path. Because this discrete event occurs quickly the value is usually captured for 1 or 2 seconds. This value is then averaged to the minute producing rainrate on the order of .009 mm/hr or less. These values are not indicative of rain and should be removed from the record or summing over long periods can bias the climate record. We are reprocessing the data to remove these small values and are adjusting the collection program to remove them before ingest. |
Measurements: | pyesmet60sM1.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
02/01/2005 | 0000 | 09/01/2005 | 2359 |
Subject: | PYE/SMET/M1 - Wind Speed data contain offset due to induced voltage |
DataStreams: | pyesmet60sM1.b1 |
Description: | The marine model of the RM Young wind sensor needs twisted pair shielded cable. The manufacturer did not originally supply the pigtail with twisted pair shielded cable. Use of twisted pair shielded cable for the rest of the cable run to the logger was also not specified. This caused an induced voltage in the wind speed line from the wind direction excitation. The induced voltage varied from sensor to sensor and probably changed anytime the cable was replaced or parts of the wind sensor were repaired or replaced. The induced voltage has been seen to vary from 0.15 m/s to as much as 1.08 m/s. |
Measurements: | pyesmet60sM1.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
02/01/2005 | 0000 | 09/15/2005 | 2359 |
Subject: | PYE/VCEIL/M1 - Reprocess: Incorrect serial_number and sum_backscatter fields |
DataStreams: | pyevceil25kM1.b1 |
Description: | Attribute serial_number: In most cases, this field is not representative of the actual serial number of the instrument because the value did not change when an instrument changed locations or was replaced with a spare. Variable sum_backscatter: An out-of-range condition for the "sum of detected and normalized backscatter" was reported as 0 instead of missing (-9999). The valid range is 0 - 0.0999 /srad. |
Measurements: | pyevceil25kM1.b1:
|