DQR ID | Subject | Data Streams Affected |
---|
D040127.5 | SGP/ECOR/E10 - Timestamp problems and intermittent data gaps | sgpecorE10.00, sgp30ecorE10.b1 |
D040408.1 | SGP/ECOR/E16 - Data suspect due to inability to run QC | sgpecorE16.00, sgp30ecorE16.b1 |
D040707.1 | SGP/ECOR/E6 - Sonic Sensor failure | sgpecorE6.00, sgp30ecorE6.b1 |
D040720.1 | SGP/ECOR/E10 - Sensor failure | sgpecorE10.00, sgp30ecorE10.b1 |
D041025.3 | SGP/ECOR/E10 - Sensor failure | sgpecorE10.00, sgp30ecorE10.b1 |
D041103.2 | SGP/ECOR/E16 - Failed IRGA | sgp30ecorE16.b1 |
D041202.1 | SGP/ECOR/E6 - Reprocess: Incorrect wind direction | sgp30ecorE6.b1 |
D041223.2 | SGP/ECOR/E16 - Missing data | sgp30ecorE16.b1 |
D050222.1 | SGP/ECOR/E6 - Reprocess: Incorrectly flagged (marked as "bad") H2O/CO2 data | sgp30ecorE6.b1 |
D050413.5 | SGP/ECOR/E10 - Reprocess: Incorrect H2O, CO2 | sgpecorE10.00, sgp30ecorE10.b1 |
D050421.1 | SGP/ECOR/E10 - Reprocess: Incorrectly flagged (marked as "bad") H2O/CO2 data | sgp30ecorE10.b1 |
D050421.2 | SGP/ECOR/E16 - Reprocess: Incorrectly flagged (marked as "bad") H2O/CO2 data | sgp30ecorE16.b1 |
D050524.1 | SGP/ECOR/E6 - Missing data | sgp30ecorE6.b1 |
D050524.3 | SGP/ECOR/E6 - Sonic Sensor failure | sgp30ecorE6.b1 |
D050912.5 | SGP/ECOR/E6 - Reprocess: Time Was 7 Hours Slow | sgp30ecorE6.b1 |
D051024.3 | SGP/ECOR/E10 - Missing data | sgp30ecorE10.b1 |
D051101.10 | SGP/ECOR/E6 - CO2 and H2O Fluxes and Means Incorrect | sgp30ecorE6.b1 |
D060104.1 | SGP/ECOR/E16 - Flux Measurements Incorrect | sgp30ecorE16.b1 |
D060531.3 | SGP/ECOR/E10 - Reprocess: Wind Direction Incorrect | sgp30ecorE10.b1 |
D060619.2 | SGP/ECOR/E10 - LI-7500 Pressure and Temperature missing | sgp30ecorE10.b1 |
D060619.4 | SGP/ECOR/E16 - LI-7500 Pressure and Temperature missing | sgp30ecorE16.b1 |
D060707.4 | SGP/ECOR/E16 - Latent Heat and CO2 Fluxes Incorrect | sgp30ecorE16.b1 |
D070509.1 | SGP/ECOR/E10 - CO2 and Latent Heat Fluxes Incorrect | sgp30ecorE10.b1 |
D080526.1 | SGP/ECOR/E10 - Incorrect CO2 fluxes | sgp30ecorE10.b1 |
Subject: | SGP/ECOR/E6 - Sonic Sensor failure |
DataStreams: | sgpecorE6.00, sgp30ecorE6.b1
|
Description: | Due to sonic sensor failure, humidity, CO2 concentration, latent heat flux, and CO2 flux
data are incorrect. |
Measurements: | sgpecorE6.00: - AVHRR satellite images for Darwin from BOM (RAW)(raw)
sgp30ecorE6.b1: - covariance uq(cvar_uq)
- kurt_c
- rotated covariance vq(cvar_rot_vq)
- lv
- time_offset
- n_good_q
- real_rho
- covaraince vc(cvar_vc)
- Momentum flux (dynamic)(k)
- time
- Mean H2O density(mean_q)
- n_spk_q
- rotated covariance vc(cvar_rot_vc)
- covariance qc(cvar_qc)
- variance of variable q(var_q)
- variance of variable c(var_c)
- Latent heat flux(lv_e)
- n_bad_c
- covariance tq(cvar_tq)
- Mean CO2 density(mean_c)
- n_spk_c
- rotated covariance uq(cvar_rot_uq)
- covariance tc(cvar_tc)
- temp_irga
- covariance uc(cvar_uc)
- n_bad_q
- Pressure, condensation, at altitude, RUC model output(cp)
- rotated covariance uc(cvar_rot_uc)
- n_bad_irga
- covaraince wq(cvar_wq)
- covariance wt(cvar_wt)
- CO2 flux(fc)
- atm_pres
- skew_c
- rho
- covariance vq(cvar_vq)
- real_cp
- rotated covariance wq(cvar_rot_wq)
- Corrected sensible heat flux(h)
- real_mr
- mean_spk_q
- skew_q
- kurt_q
- rotated covariance wc(cvar_rot_wc)
- mr
- covariance wc(cvar_wc)
- real_lv
- n_bad_irga_light
- mean_cooler
- n_good_c
- mean_spk_c
|
Subject: | SGP/ECOR/E10 - Sensor failure |
DataStreams: | sgpecorE10.00, sgp30ecorE10.b1
|
Description: | Due to sensor failure all the parameters measured by the Infrared Gas Analyzer (water
vapor density, CO2 concentration, fluxes of latent heat and CO2, etc.) are incorrect for the
period of 18:30 Oct. 22, 2004 to 22:00 Dec. 14, 2004. The data is irrevocably lost. |
Measurements: | sgpecorE10.00: - AVHRR satellite images for Darwin from BOM (RAW)(raw)
sgp30ecorE10.b1: - covariance wc(cvar_wc)
- n_good_c
- atm_pres
- real_cp
- n_bad_irga
- skew_c
- rotated covariance wq(cvar_rot_wq)
- kurt_q
- variance of variable q(var_q)
- Mean H2O density(mean_q)
- rho
- covariance uc(cvar_uc)
- covariance uq(cvar_uq)
- n_bad_son_ic
- rotated covariance uq(cvar_rot_uq)
- covariance qc(cvar_qc)
- Pressure, condensation, at altitude, RUC model output(cp)
- covariance vq(cvar_vq)
- n_bad_irga_light
- rotated covariance uc(cvar_rot_uc)
- mean_spk_c
- n_spk_c
- rotated covariance wc(cvar_rot_wc)
- variance of variable c(var_c)
- mean_spk_q
- covaraince vc(cvar_vc)
- Latent heat flux(lv_e)
- mr
- temp_irga
- covariance tc(cvar_tc)
- n_bad_c
- real_rho
- rotated covariance vq(cvar_rot_vq)
- n_spk_q
- covariance tq(cvar_tq)
- real_lv
- n_good_q
- covaraince wq(cvar_wq)
- real_mr
- mean_cooler
- n_bad_q
- CO2 flux(fc)
- rotated covariance vc(cvar_rot_vc)
- Mean CO2 density(mean_c)
- kurt_c
- skew_q
|
Subject: | SGP/ECOR/E16 - Failed IRGA |
DataStreams: | sgp30ecorE16.b1
|
Description: | The infrared gas analyzer (IRGA) failed on Nov. 2, 2004, 02:00; the system continued to
operate without H2O and CO2 data until Nov. 9, 2004, 15:30; then it stopped due to another
hardware failure. The system was returned to service on Nov. 12, 2004, 18:00.
The latent heat flux and CO2 flux data are irrevocably lost for the period from Nov. 2,
2004, 02:00 to Nov. 12, 2004, 18:00. |
Measurements: | sgp30ecorE16.b1: - real_mr
- n_bad_irga_light
- covaraince vc(cvar_vc)
- mean_spk_c
- kurt_q
- Latent heat flux(lv_e)
- skew_q
- rotated covariance vc(cvar_rot_vc)
- covariance uq(cvar_uq)
- variance of variable c(var_c)
- n_spk_c
- real_cp
- rotated covariance vq(cvar_rot_vq)
- Mean CO2 density(mean_c)
- mean_spk_q
- CO2 flux(fc)
- atm_pres
- lv
- covariance qc(cvar_qc)
- covaraince wq(cvar_wq)
- kurt_c
- variance of variable q(var_q)
- covariance wc(cvar_wc)
- covariance uc(cvar_uc)
- rotated covariance uq(cvar_rot_uq)
- n_good_q
- Pressure, condensation, at altitude, RUC model output(cp)
- n_good_c
- real_lv
- n_spk_q
- n_bad_irga
- temp_irga
- real_rho
- n_bad_q
- mr
- n_bad_c
- rotated covariance wc(cvar_rot_wc)
- rotated covariance uc(cvar_rot_uc)
- covariance tq(cvar_tq)
- rotated covariance wq(cvar_rot_wq)
- rho
- covariance tc(cvar_tc)
- covariance vq(cvar_vq)
- mean_cooler
- skew_c
- Mean H2O density(mean_q)
|
Subject: | SGP/ECOR/E10 - Reprocess: Incorrect H2O, CO2 |
DataStreams: | sgpecorE10.00, sgp30ecorE10.b1
|
Description: | Due to failure of analog output circuitry in the Infrared Gas Analyzer (IRGA), CO2 and
water vapor parameters measured by the IRGA (water vapor density, CO2 concentration, fluxes
of latent heat and CO2) were incorrectly recorded in sonic raw data files for the period
of 22:30 Dec. 14, 2004 to 22:00 Jan. 11, 2005. The data could be recovered from IRGA raw
serial files (00 level). |
Measurements: | sgpecorE10.00: - AVHRR satellite images for Darwin from BOM (RAW)(raw)
sgp30ecorE10.b1: - covariance wc(cvar_wc)
- n_good_c
- real_cp
- n_bad_irga
- skew_c
- rotated covariance wq(cvar_rot_wq)
- kurt_q
- variance of variable q(var_q)
- Mean H2O density(mean_q)
- rho
- covariance uc(cvar_uc)
- covariance uq(cvar_uq)
- rotated covariance uq(cvar_rot_uq)
- covariance qc(cvar_qc)
- Pressure, condensation, at altitude, RUC model output(cp)
- covariance vq(cvar_vq)
- rotated covariance uc(cvar_rot_uc)
- mean_spk_c
- n_spk_c
- rotated covariance wc(cvar_rot_wc)
- variance of variable c(var_c)
- mean_spk_q
- covaraince vc(cvar_vc)
- Latent heat flux(lv_e)
- lv
- mr
- covariance tc(cvar_tc)
- n_bad_c
- real_rho
- rotated covariance vq(cvar_rot_vq)
- n_spk_q
- covariance tq(cvar_tq)
- real_lv
- n_good_q
- covaraince wq(cvar_wq)
- real_mr
- n_bad_q
- CO2 flux(fc)
- rotated covariance vc(cvar_rot_vc)
- Mean CO2 density(mean_c)
- kurt_c
- skew_q
|