DQR ID | Subject | Data Streams Affected |
---|---|---|
D051101.9 | SGP/ECOR/E5 - Missing data | sgp30ecorE5.b1 |
D060616.3 | SGP/ECOR/E5 - CO2 and Water Vapor Fluxes and Means Incorrect | sgp30ecorE5.b1 |
D070227.1 | SGP/ECOR/E5 - Reprocess: Time shifted -7 hours | sgpecorE5.00, sgp30ecorE5.b1 |
D070510.1 | SGP/ECOR/E5 - Flux Measurements Incorrect | sgp30ecorE5.b1 |
D070619.1 | SGP/ECOR/E5 - Flux Data Incorrect | sgp30ecorE5.b1 |
D090217.2 | SGP/ECOR/E5 - Incorrect Sensible and Latent Heat Fluxes | sgp30ecorE5.b1 |
Start Date | Start Time | End Date | End Time |
---|---|---|---|
01/04/2005 | 2230 | 01/12/2005 | 1830 |
Subject: | SGP/ECOR/E5 - Missing data |
DataStreams: | sgp30ecorE5.b1 |
Description: | Data are missing and unrecoverable. |
Measurements: | sgp30ecorE5.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
06/14/2006 | 2130 | 06/17/2006 | 1030 |
Subject: | SGP/ECOR/E5 - CO2 and Water Vapor Fluxes and Means Incorrect |
DataStreams: | sgp30ecorE5.b1 |
Description: | The LI-7500 at E5 ECOR did not putting out data during this period. Therefore, CO2 and H2O fluxes and means were incorrect during the period. |
Measurements: | sgp30ecorE5.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
02/21/2007 | 1900 | 02/23/2007 | 2330 |
Subject: | SGP/ECOR/E5 - Reprocess: Time shifted -7 hours |
DataStreams: | sgpecorE5.00, sgp30ecorE5.b1 |
Description: | An inadvertant power outage caused the ECOR program to shut down abnormally. When power was restored, the timestamps on the ECOR files were 7 hours behind the correct time and the site ID was not accessed from the ECOR configuration file resulting in site ID (05) being replaced with "AN". These conditions caused the ECOR files to be unrecognizable and therefore are presently missing in the Archive. Correction of the timestamp and ID in the files should allow them to be processed and added to the Archive. |
Measurements: | sgpecorE5.00:
sgp30ecorE5.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
11/20/2005 | 1930 | 12/14/2005 | 1930 |
04/18/2007 | 1930 | 05/17/2007 | 1815 |
Subject: | SGP/ECOR/E5 - Flux Measurements Incorrect |
DataStreams: | sgp30ecorE5.b1 |
Description: | The ECOR datastream was corrupted; this happens when the ECOR program produces a datastream of the wrong length (i.e., leaves one or more measurements out). Fluxes and some other measurements are incorrect. Note: Mentor reports reprocessing will not correct this problem. |
Measurements: | sgp30ecorE5.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
06/16/2007 | 0300 | 12/12/2007 | 2030 |
Subject: | SGP/ECOR/E5 - Flux Data Incorrect |
DataStreams: | sgp30ecorE5.b1 |
Description: | CO2 flux (lv_e) and latent heat flux (fc) were incorrect because the sonic anemometer was not working. |
Measurements: | sgp30ecorE5.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
02/16/2009 | 0400 | 04/01/2009 | 1730 |
04/06/2009 | 0400 | 04/06/2009 | 1730 |
04/24/2009 | 1400 | 04/29/2009 | 2230 |
Subject: | SGP/ECOR/E5 - Incorrect Sensible and Latent Heat Fluxes |
DataStreams: | sgp30ecorE5.b1 |
Description: | Starting at approximately 4:00 GMT on 02/16, the ECOR suffered from the "garbled" data condition, a result of a serial communication failure. All sensible and latent heat flux measurements are incorrect during this condition. |
Measurements: | sgp30ecorE5.b1:
|