DQR ID | Subject | Data Streams Affected |
---|
D070208.3 | SGP/EBBR/E2 - Missing data | sgp5ebbrE2.b1, sgp15ebbrE2.b1, sgp30ebbrE2.b1 |
D070215.2 | SGP/EBBR/E2 - Windspeed sensor failure | sgp5ebbrE2.b1, sgp15ebbrE2.b1, sgp30ebbrE2.b1 |
D070215.3 | SGP/EBBR/E7 - Windspeed threshhold too high | sgp5ebbrE7.b1, sgp15ebbrE7.b1, sgp30ebbrE7.b1 |
D070223.2 | SGP/EBBR/E8 - Failed Temp/RH sensor | sgp5ebbrE8.b1, sgp15ebbrE8.b1, sgp30ebbrE8.b1 |
D070328.1 | SGP/EBBR/E4 - Wind Direction Stuck at Zero | sgp5ebbrE4.b1, sgp15ebbrE4.b1, sgp30ebbrE4.b1 |
D070426.1 | SGP/EBBR/E22 - Wind Direction Incorrect | sgp5ebbrE22.b1, sgp15ebbrE22.b1, sgp30ebbrE22.b1 |
D070508.1 | SGP/EBBR/E4 - Instrument problem | sgp5ebbrE4.b1, sgp15ebbrE4.b1, sgp30ebbrE4.b1 |
D070716.2 | SGP/EBBR/E20 - Reprocess: Wind Direction 20 Degrees Low | sgp5ebbrE20.b1, sgp15ebbrE20.b1, sgp30ebbrE20.b1 |
D070809.1 | SGP/EBBR/E27 - Multiplexer #2 failure | sgp5ebbrE27.b1, sgp15ebbrE27.b1, sgp30ebbrE27.b1 |
D070810.1 | SGP/EBBR/E4 - Wind Direction Incorrect | sgp5ebbrE4.b1, sgp15ebbrE4.b1, sgp30ebbrE4.b1 |
D070815.6 | SGP/EBBR/E22 - H and LE Incorrect | sgp15ebbrE22.b1, sgp30ebbrE22.b1 |
D071001.1 | SGP/EBBR/E26 - Sensible and Latent Heat Fluxes Affected by bad temp sensor | sgp5ebbrE26.b1, sgp15ebbrE26.b1, sgp30ebbrE26.b1 |
D071115.1 | SGP/EBBR/E20 - Reprocess: Wind Direction 65 Degrees Low | sgp5ebbrE20.b1, sgp15ebbrE20.b1, sgp30ebbrE20.b1 |
D080102.2 | SGP/EBBR/E9 - Net Radiation Incorrect | sgp5ebbrE9.b1, sgp15ebbrE9.b1, sgp30ebbrE9.b1 |
D080114.3 | SGP/EBBR/E27 - Measurements offscale | sgp5ebbrE27.b1, sgp15ebbrE27.b1, sgp30ebbrE27.b1 |
D080509.2 | SGP/EBBR/E4 - Reprocess: Wind Direction Incorrect | sgp5ebbrE4.b1, sgp15ebbrE4.b1, sgp30ebbrE4.b1 |
D110105.3 | SGP/EBBR/E8 - RH Maximum too high | sgp5ebbrE8.b1, sgp15ebbrE8.b1, sgp30ebbrE8.b1 |
Subject: | SGP/EBBR/E2 - Missing data |
DataStreams: | sgp5ebbrE2.b1, sgp15ebbrE2.b1, sgp30ebbrE2.b1
|
Description: | Data are missing and unrecoverable |
Measurements: | sgp15ebbrE2.b1: - rh_right_mv
- Wind speed arithmetic mean(wspd_arith_mean)
- soil_temp_1_rr
- lat
- soil_heat_flow_5_mv
- soil_moisture_4_rr
- rh_left_mv
- time_offset
- soil_heat_flow_4_mv
- lon
- soil_heat_flow_3_mv
- temp_reference_rr
- soil_moisture_5_rr
- soil_moisture_1_rr
- soil_temp_5_rr
- base_time
- soil_temp_2_rr
- temp_trh_left_rr
- home_signal
- atmos_pressure_mv
- soil_moisture_2_rr
- temp_air_left
- net_radiation_mv
- soil_heat_flow_1_mv
- soil_temp_3_rr
- wdir_vec_mean_mv
- soil_heat_flow_2_mv
- temp_air_right
- soil_moisture_3_rr
- alt
- soil_temp_4_rr
- temp_trh_right_rr
- battery_voltage
sgp30ebbrE2.b1: - energy_storage_change_1
- energy_storage_change_4
- energy_storage_change_5
- energy_storage_change_2
- soil_temp_5
- Wind speed arithmetic mean(wspd_arith_mean)
- energy_storage_change_3
- soil_temp_3
- soil_temp_4
- soil_temp_1
- soil_temp_2
- temp_air_top
- soil_heat_flow_4
- soil_heat_flow_5
- soil_heat_flow_1
- soil_heat_flow_2
- soil_heat_flow_3
- soil_moisture_4
- soil_moisture_3
- vapor_pressure_top
- soil_moisture_2
- soil_moisture_1
- temp_air_bottom
- soil_moisture_5
- rh_top_fraction
- Wind speed vector mean(wspd_vec_mean)
- alt
- corr_soil_heat_flow_5
- corr_soil_heat_flow_1
- corr_soil_heat_flow_2
- corr_soil_heat_flow_3
- corr_soil_heat_flow_4
- Atmospheric pressure(atmos_pressure)
- temp_reference
- rh_bottom_fraction
- time_offset
- base_time
- vapor_pressure_bottom
- lat
- home_signal_30
- temp_trh_bottom
- soil_heat_capacity_1
- soil_heat_capacity_2
- soil_heat_capacity_3
- soil_heat_capacity_5
- soil_heat_capacity_4
- Wind direction vector mean(wdir_vec_mean)
- Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
- Average soil heat flow at the surface(surface_soil_heat_flux_avg)
- home_signal_15
- Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
- Radiation, net(net_radiation)
- lon
- temp_trh_top
- surface_soil_heat_flux_1
- surface_soil_heat_flux_2
- bowen_ratio
- wdir_vec_std
- surface_soil_heat_flux_5
- surface_soil_heat_flux_4
- surface_soil_heat_flux_3
sgp5ebbrE2.b1: - home_signal
- Radiation, net(net_radiation)
- time
- Wind speed arithmetic mean(wspd_arith_mean)
- time_offset
- vapor_pressure_top
- rh_top_fraction
- Wind direction vector mean(wdir_vec_mean)
- alt
- temp_reference
- lon
- lat
- temp_air_bottom
- Wind speed vector mean(wspd_vec_mean)
- Atmospheric pressure(atmos_pressure)
- base_time
- rh_bottom_fraction
- temp_trh_bottom
- wdir_vec_std
- temp_trh_top
- vapor_pressure_bottom
- temp_air_top
|
Subject: | SGP/EBBR/E8 - Failed Temp/RH sensor |
DataStreams: | sgp5ebbrE8.b1, sgp15ebbrE8.b1, sgp30ebbrE8.b1
|
Description: | The right Temperature-Humidity sensor failed. The measured temperature gradients were
incorrect and thus the sensible and latent heat fluxes were incorrect for this extended
period.
The sensor was replaced March 6. |
Measurements: | sgp15ebbrE8.b1:
sgp5ebbrE8.b1: - vapor_pressure_bottom
- temp_trh_top
- vapor_pressure_top
- temp_trh_bottom
sgp30ebbrE8.b1: - vapor_pressure_bottom
- temp_trh_bottom
- vapor_pressure_top
- Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
- bowen_ratio
- temp_trh_top
- Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
|
Subject: | SGP/EBBR/E27 - Multiplexer #2 failure |
DataStreams: | sgp5ebbrE27.b1, sgp15ebbrE27.b1, sgp30ebbrE27.b1
|
Description: | A problem with the #2 Multiplexer caused a large number of measurements to be incorrect.
Sensible and latent heat fluxes were often affected. |
Measurements: | sgp5ebbrE27.b1: - rh_top_fraction
- rh_bottom_fraction
- vapor_pressure_bottom
- temp_air_bottom
- temp_air_top
- Radiation, net(net_radiation)
- home_signal
- Atmospheric pressure(atmos_pressure)
- vapor_pressure_top
sgp15ebbrE27.b1: - soil_heat_flow_2_mv
- atmos_pressure_mv
- soil_heat_flow_4_mv
- soil_heat_flow_1_mv
- temp_air_left
- home_signal
- soil_heat_flow_3_mv
- soil_heat_flow_5_mv
- rh_right_mv
- net_radiation_mv
- temp_air_right
- rh_left_mv
sgp30ebbrE27.b1: - Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
- soil_heat_flow_1
- surface_soil_heat_flux_2
- soil_heat_flow_2
- surface_soil_heat_flux_3
- surface_soil_heat_flux_4
- surface_soil_heat_flux_5
- soil_heat_flow_5
- soil_heat_flow_3
- soil_heat_flow_4
- Radiation, net(net_radiation)
- home_signal_30
- rh_bottom_fraction
- rh_top_fraction
- surface_soil_heat_flux_1
- vapor_pressure_top
- corr_soil_heat_flow_1
- temp_air_top
- Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
- home_signal_15
- temp_air_bottom
- Average soil heat flow at the surface(surface_soil_heat_flux_avg)
- bowen_ratio
- corr_soil_heat_flow_2
- vapor_pressure_bottom
- corr_soil_heat_flow_3
- corr_soil_heat_flow_4
- corr_soil_heat_flow_5
|
Subject: | SGP/EBBR/E22 - H and LE Incorrect |
DataStreams: | sgp15ebbrE22.b1, sgp30ebbrE22.b1
|
Description: | Soil Heat Flow 1 bounced around and went offscale at times, resulting in the EBBR program
setting sensible and latent heat fluxes to 9999es.
The problem ended during a PM visit, possibly because of routine checks and tightening of
leads in terminal strips. |
Measurements: | sgp30ebbrE22.b1: - Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
- Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
- corr_soil_heat_flow_1
- soil_heat_flow_1
- surface_soil_heat_flux_1
- Average soil heat flow at the surface(surface_soil_heat_flux_avg)
sgp15ebbrE22.b1:
|
Subject: | SGP/EBBR/E26 - Sensible and Latent Heat Fluxes Affected by bad temp sensor |
DataStreams: | sgp5ebbrE26.b1, sgp15ebbrE26.b1, sgp30ebbrE26.b1
|
Description: | The left Thum (temperature of the humidity sensor chamber) measurement was incorrect at
times, affecting several measurements, including the sensible and latent heat fluxes. |
Measurements: | sgp30ebbrE26.b1: - vapor_pressure_bottom
- temp_trh_top
- bowen_ratio
- Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
- temp_trh_bottom
- vapor_pressure_top
- Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
sgp15ebbrE26.b1:
sgp5ebbrE26.b1: - temp_trh_top
- temp_trh_bottom
- vapor_pressure_bottom
- vapor_pressure_top
|
Subject: | SGP/EBBR/E9 - Net Radiation Incorrect |
DataStreams: | sgp5ebbrE9.b1, sgp15ebbrE9.b1, sgp30ebbrE9.b1
|
Description: | There was water in the net radiometer.
The net radiation data was incorrect. |
Measurements: | sgp30ebbrE9.b1: - Radiation, net(net_radiation)
- Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
- Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
sgp15ebbrE9.b1:
sgp5ebbrE9.b1: - Radiation, net(net_radiation)
|
Subject: | SGP/EBBR/E27 - Measurements offscale |
DataStreams: | sgp5ebbrE27.b1, sgp15ebbrE27.b1, sgp30ebbrE27.b1
|
Description: | All J-panel 4 measurements (soil heat flows, net radiation, air temperatures, home
signals, pressure, vapor pressure) were sometimes offscale or otherwise incorrect. J-Panel was
replaced 20080326 correcting the problem. |
Measurements: | sgp5ebbrE27.b1: - temp_air_bottom
- temp_air_top
- Radiation, net(net_radiation)
- home_signal
- Atmospheric pressure(atmos_pressure)
- vapor_pressure_top
- vapor_pressure_bottom
sgp15ebbrE27.b1: - soil_heat_flow_2_mv
- home_signal
- soil_heat_flow_3_mv
- soil_heat_flow_5_mv
- soil_heat_flow_4_mv
- atmos_pressure_mv
- net_radiation_mv
- temp_air_right
- soil_heat_flow_1_mv
- temp_air_left
sgp30ebbrE27.b1: - corr_soil_heat_flow_1
- Heat flux, latent, at 1.5-m height, 30-min intervals(latent_heat_flux)
- surface_soil_heat_flux_2
- soil_heat_flow_1
- surface_soil_heat_flux_3
- soil_heat_flow_2
- surface_soil_heat_flux_4
- surface_soil_heat_flux_5
- soil_heat_flow_5
- soil_heat_flow_3
- soil_heat_flow_4
- Radiation, net(net_radiation)
- temp_air_top
- Heat flux, sensible, at 1.5-m height, 30-min intervals(sensible_heat_flux)
- home_signal_30
- Atmospheric pressure(atmos_pressure)
- home_signal_15
- temp_air_bottom
- surface_soil_heat_flux_1
- vapor_pressure_top
- vapor_pressure_bottom
- corr_soil_heat_flow_2
- corr_soil_heat_flow_3
- corr_soil_heat_flow_4
- corr_soil_heat_flow_5
|