DQR ID | Subject | Data Streams Affected |
---|---|---|
D080428.4 | TWP/SMET/C2 - Reprocess: ORG Data has very small rainrate values | twpsmet60sC2.b1 |
D080617.1 | TWP/SMET/C2 - ORG rainfall measurements too large | twpsmet60sC2.b1 |
D081022.5 | TWP/SMET/C2 - Wind Speed data contain offset due to induced voltage | twpsmet60sC2.b1 |
D100215.5 | TWP/VCEIL/C2 - Reprocess: Incorrect serial_number and sum_backscatter fields | twpvceil25kC2.b1 |
Start Date | Start Time | End Date | End Time |
---|---|---|---|
07/01/2004 | 0000 | 06/30/2010 | 2359 |
Subject: | TWP/SMET/C2 - Reprocess: ORG Data has very small rainrate values |
DataStreams: | twpsmet60sC2.b1 |
Description: | The ORG data is collected via analog signal and not digital. Therefore, we continuously collect data even when no rain is occurring. We also capture small events such as leaves, large bugs, dust, etc blowing through the measurement path. Because this discrete event occurs quickly the value is usually captured for 1 or 2 seconds. This value is then averaged to the minute producing rainrate on the order of .009 mm/hr or less. These values are not indicative of rain and should be removed from the record or summing over long periods can bias the climate record. We will reprocess the data to remove these small values. |
Measurements: | twpsmet60sC2.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
05/08/2008 | 0000 | 08/07/2008 | 2300 |
Subject: | TWP/SMET/C2 - ORG rainfall measurements too large |
DataStreams: | twpsmet60sC2.b1 |
Description: | The ORG was collecting large amounts of rainfall compared to the co-located tipping bucket raingauge. The cable was chewed by mice causing the wires to make contact intermittently mimicking rainfall. |
Measurements: | twpsmet60sC2.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
11/01/1998 | 0000 | 02/23/2009 | 0410 |
Subject: | TWP/SMET/C2 - Wind Speed data contain offset due to induced voltage |
DataStreams: | twpsmet60sC2.b1 |
Description: | The marine model of the RM Young wind sensor needs twisted pair shielded cable. The manufacturer did not originally supply the pigtail with twisted pair shielded cable. Use of twisted pair shielded cable for the rest of the cable run to the logger was also not specified. This caused an induced voltage in the wind speed line from the wind direction excitation. The induced voltage varied from sensor to sensor and probably changed anytime the cable was replaced or parts of the wind sensor were repaired or replaced. The induced voltage has been seen to vary from 0.15 m/s to as much as 1.08 m/s. |
Measurements: | twpsmet60sC2.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/28/1998 | 0000 | 10/31/2009 | 2359 |
Subject: | TWP/VCEIL/C2 - Reprocess: Incorrect serial_number and sum_backscatter fields |
DataStreams: | twpvceil25kC2.b1 |
Description: | Attribute serial_number: In most cases, this field is not representative of the actual serial number of the instrument because the value did not change when an instrument changed locations or was replaced with a spare. Variable sum_backscatter: An out-of-range condition for the "sum of detected and normalized backscatter" was reported as 0 instead of missing (-9999). The valid range is 0 - 0.0999 /srad. This DQR also applies to a1 level data. |
Measurements: | twpvceil25kC2.b1:
|