DQR ID | Subject | Data Streams Affected |
---|---|---|
D010713.17 | SGP/SMOS/E7 - E7 SMOS Wind speed values incorrect | sgp1smosE7.a0, sgp30smosE7.a1 |
D010713.21 | SGP/SMOS/E8 - E8 SMOS Wind speed sensor data incorrect | sgp1smosE8.a0, sgp30smosE8.a1 |
D010713.32 | SGP/SMOS/E8 - E8 SMOS RH values beyond tolerance | sgp1smosE8.a0, sgp30smosE8.a1, sgp1440smosE8.a0 |
D010725.22 | SGP/SMOS/E8 - E8 SMOS RH VALUES OUTSIDE OF TOLERANCE | sgp1smosE8.a0, sgp30smosE8.a1 |
D010725.3 | SGP/SMOS/E8 - E8 WS DATA INCORRECT | sgp1smosE8.a0, sgp30smosE8.a1 |
D010727.1 | SGP/SMOS/E8 - E8 SMOS RH DATA VALUES ARTIFICIALLY HIGH | sgp1smosE8.a0, sgp30smosE8.a1, sgp1440smosE8.a0 |
D020614.3 | SGP/SMOS/E8 - Reprocess: Wind speed calibration | sgp1smosE8.a0, sgp30smosE8.a1 |
D020619.1 | SGP/SMOS/E7 - E7 SMOS lowered to surface to install counterweights | sgpsmosE7.01, sgp1smosE7.00, sgp1smosE7.a0, sgp30smosE7.a1, sgp1440smosE7.a0 |
D020619.3 | SGP/SMOS/E8 - Incorrect E8 SMOS rain data | sgp1smosE8.00, sgp1smosE8.a0, sgp30smosE8.a1 |
D020619.4 | SGP/SMOS/E8 - E8 SMOS lowered to surface to install counterweights | sgpsmosE8.01, sgp1smosE8.00, sgp1smosE8.a0, sgp30smosE8.a1, sgp1440smosE8.a0 |
D040317.2 | SGP/SMOS/E6 - 6-month Calibration Checks | sgp1smosE6.a0, sgp30smosE6.a1, sgp1440smosE6.a0 |
D040317.5 | SGP/SMOS/E7 - 6-month Calibration Checks | sgp1smosE7.a0, sgp30smosE7.a1, sgp1440smosE7.a0 |
D040317.8 | SGP/SMOS/E8 - 6-month Calibration Checks | sgp1smosE8.a0, sgp30smosE8.a1, sgp1440smosE8.a0 |
D050422.6 | SGP/SMOS/E7 - Reprocess: Wind direction offset | sgp1smosE7.a0, sgp30smosE7.a1 |
D081010.6 | SGP/SMOS/E7 - RH values incorrect | sgp1smosE7.a0, sgp30smosE7.a1, sgp1440smosE7.a0 |
D950428.2 | SGP/SMOS/E7 - Reprocess: Incorrect Wind Speed data from SMOS E7 | sgp1smosE7.a0, sgp30smosE7.a1, sgp1440smosE7.a0 |
D950814.1 | SGP/SMOS/E7 - Questionable Humidity data | sgp1smosE7.a0, sgp30smosE7.a1, sgp1440smosE7.a0 |
D951009.3 | SGP/SMOS/E8 - Reprocess: Incorrect wind speed calibration | sgp1smosE8.a0, sgp30smosE8.a1, sgp1440smosE8.a0 |
D970328.2 | SGP/SMOS/E7 - Reprocess: Wind direction incorrect | sgp1smosE7.a0, sgp30smosE7.a1 |
D970507.1 | SGP/SMOS/E7 - Humidity data drifted out of tolerance | sgp1smosE7.a0, sgp30smosE7.a1 |
D971006.1 | SGP/SMOS/E8 - Reprocess: Incorrect wind directions from E8 SMOS | sgp1smosE8.a0, sgp30smosE8.a1 |
D971112.10 | SGP/SMOS/E8 - Questionable E8 SMOS rain data | sgp1smosE8.00, sgp1smosE8.a0, sgp30smosE8.a1 |
D980401.3 | SGP/SMOS/E8 - Icing affected E8 SMOS wind speed | sgp1smosE8.00, sgp1smosE8.a0, sgp30smosE8.a1, sgp1440smosE8.a0 |
D991109.23 | SGP/SMOS/E8 - E8 SMOS lowered to surface to install couterweights | sgpsmosE8.01, sgp1smosE8.00, sgp1smosE8.a0, sgp30smosE8.a1, sgp1440smosE8.a0 |
D991109.24 | SGP/SMOS/E7 - E7 SMOS lowered to surface to install counterweights | sgpsmosE7.01, sgp1smosE7.00, sgp1smosE7.a0, sgp30smosE7.a1, sgp1440smosE7.a0 |
D991109.5 | SGP/SMOS/E6 - E6 SMOS down for tower replacement | sgpsmosE6.01, sgp1smosE6.00, sgp1smosE6.a0, sgp30smosE6.a1, sgp1440smosE6.a0 |
D991109.6 | SGP/SMOS/E7 - E7 SMOS down for tower replacement | sgpsmosE7.01, sgp1smosE7.00, sgp1smosE7.a0, sgp30smosE7.a1, sgp1440smosE7.a0 |
Start Date | Start Time | End Date | End Time |
---|---|---|---|
01/28/2001 | 0607 | 01/29/2001 | 0932 |
Subject: | SGP/SMOS/E7 - E7 SMOS Wind speed values incorrect |
DataStreams: | sgp1smosE7.a0, sgp30smosE7.a1 |
Description: | Wind speed sensor had ice accumulation causing wind speed data to be incorrect. |
Measurements: | sgp30smosE7.a1:
sgp1smosE7.a0:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
01/28/2001 | 2354 | 01/29/2001 | 0501 |
Subject: | SGP/SMOS/E8 - E8 SMOS Wind speed sensor data incorrect |
DataStreams: | sgp1smosE8.a0, sgp30smosE8.a1 |
Description: | Wind speed sensor had ice accumulation causing data to be incorrect. |
Measurements: | sgp30smosE8.a1:
sgp1smosE8.a0:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
01/11/2001 | 0148 | 01/13/2001 | 0631 |
Subject: | SGP/SMOS/E8 - E8 SMOS RH values beyond tolerance |
DataStreams: | sgp1smosE8.a0, sgp30smosE8.a1, sgp1440smosE8.a0 |
Description: | RH% values reading above 103%, which is beyond tolerance. |
Measurements: | sgp30smosE8.a1:
sgp1440smosE8.a0:
sgp1smosE8.a0:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
02/13/2001 | 1835 | 02/14/2001 | 1436 |
Subject: | SGP/SMOS/E8 - E8 SMOS RH VALUES OUTSIDE OF TOLERANCE |
DataStreams: | sgp1smosE8.a0, sgp30smosE8.a1 |
Description: | Rh% values readings falling outside of tolerance on high side |
Measurements: | sgp30smosE8.a1:
sgp1smosE8.a0:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
02/08/2001 | 1016 | 02/11/2001 | 1009 |
Subject: | SGP/SMOS/E8 - E8 WS DATA INCORRECT |
DataStreams: | sgp1smosE8.a0, sgp30smosE8.a1 |
Description: | WS data artificially low due to ice accumulation on sensor. |
Measurements: | sgp30smosE8.a1:
sgp1smosE8.a0:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
03/21/2001 | 0000 | 03/31/2001 | 2359 |
Subject: | SGP/SMOS/E8 - E8 SMOS RH DATA VALUES ARTIFICIALLY HIGH |
DataStreams: | sgp1smosE8.a0, sgp30smosE8.a1, sgp1440smosE8.a0 |
Description: | Rh% values approximately 10% at 70% and above. Sensor drifted out of tolerance. |
Measurements: | sgp30smosE8.a1:
sgp1440smosE8.a0:
sgp1smosE8.a0:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
07/28/1993 | 0001 | 08/11/1993 | 1530 |
Subject: | SGP/SMOS/E8 - Reprocess: Wind speed calibration |
DataStreams: | sgp1smosE8.a0, sgp30smosE8.a1 |
Description: | EDITOR'S NOTE: The earliest portion of the period of time covered by this DQR occurred prior to the begin date of regular ARM data. Those data are not readily available from the ARM archive, but are available upon request. The actual period of time covered by this DQR is 930403.0000-930811.1530. Practically all of the information in this DQR is derived from P930723.1 and C930830.1, both of which were submitted by Dick Hart. The calibrations initially used for wind speeds on SMOS systems at Coldwater (E8), Ashton (E9), the central faciality (E13), Ringwood (E15), and Meeker (E20) were originally "generic"values, but analysis of the N.I.S.T traceable calibration data reveals that use of these "generic" calibrations produces data with insufficient accuracy. The calibrations for the wind speed sensor associated with the instrument must be used in the datalogger program in order to obtain data with a 1% uncertainty. For the worst case, one wind speed sensor underestimates the wind speed by 1.1 m/s at 30 m/s when the "generic" calibration is used. This is on top of the 1% calibration uncertainty. No unreported data loss occurred as a result of this calibration question, but users of the data should adjust the wind speed values before analysis involving these wind speed values. |
Measurements: | sgp30smosE8.a1:
sgp1smosE8.a0:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/08/1999 | 0740 | 10/08/1999 | 0755 |
Subject: | SGP/SMOS/E7 - E7 SMOS lowered to surface to install counterweights |
DataStreams: | sgpsmosE7.01, sgp1smosE7.00, sgp1smosE7.a0, sgp30smosE7.a1, sgp1440smosE7.a0 |
Description: | The E7 SMOS was lowered to the surface on 8 OCT 1999 between 0740 and 0755 GMT while counterweights were installed. All wind speed and direction data are incorrect during this period. |
Measurements: | sgpsmosE7.01:
sgp30smosE7.a1:
sgp1smosE7.a0:
sgp1440smosE7.a0:
sgp1smosE7.00:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
09/16/1997 | 0000 | 10/29/1997 | 1815 |
Subject: | SGP/SMOS/E8 - Incorrect E8 SMOS rain data |
DataStreams: | sgp1smosE8.00, sgp1smosE8.a0, sgp30smosE8.a1 |
Description: | The E8 SMOS rain gauge pulse counter was found to be non-operational during the 16 SEP 97 PM. It was repaired by replacing the CR10 wiring harness on 29 OCT 97 at 1815 GMT. |
Measurements: | sgp30smosE8.a1:
sgp1smosE8.00:
sgp1smosE8.a0:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/05/1999 | 1325 | 10/05/1999 | 1350 |
Subject: | SGP/SMOS/E8 - E8 SMOS lowered to surface to install counterweights |
DataStreams: | sgpsmosE8.01, sgp1smosE8.00, sgp1smosE8.a0, sgp30smosE8.a1, sgp1440smosE8.a0 |
Description: | The E8 SMOS was lowered to the surface on 5 OCT 1999 between 1325 and 1350 GMT while counterweights were installed. All wind speed and direction data are incorrect during this period. |
Measurements: | sgp30smosE8.a1:
sgpsmosE8.01:
sgp1440smosE8.a0:
sgp1smosE8.00:
sgp1smosE8.a0:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
05/01/1996 | 1614 | 05/01/1996 | 1710 |
11/14/1996 | 2010 | 11/14/1996 | 2120 |
04/29/1997 | 1745 | 04/29/1997 | 1945 |
10/14/1997 | 1850 | 10/14/1997 | 1910 |
05/13/1998 | 1500 | 05/13/1998 | 1530 |
11/12/1998 | 1500 | 11/12/1998 | 1730 |
04/01/1999 | 1510 | 04/01/1999 | 1520 |
05/12/1999 | 2052 | 05/12/1999 | 2120 |
12/08/1999 | 1939 | 12/08/1999 | 2015 |
05/10/2000 | 1820 | 05/10/2000 | 2020 |
09/28/2000 | 1420 | 09/28/2000 | 1530 |
Subject: | SGP/SMOS/E6 - 6-month Calibration Checks |
DataStreams: | sgp1smosE6.a0, sgp30smosE6.a1, sgp1440smosE6.a0 |
Description: | During the time periods specified, the SMOS.E6 tower was lowered for 6-month Calibration Checks. During these times wind data are incorrect and temperature and humidity data may be incorrect. Note, exact times when tower was down or maintenance was being performed is sometimes unknown. Users should use the remaining data from these days with caution. |
Measurements: | sgp30smosE6.a1:
sgp1440smosE6.a0:
sgp1smosE6.a0:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/04/1995 | 1553 | 10/04/1995 | 1654 |
05/02/1996 | 1521 | 05/02/1996 | 1605 |
11/13/1996 | 1645 | 11/13/1996 | 1810 |
04/16/1997 | 1415 | 04/16/1997 | 1523 |
10/16/1997 | 1530 | 10/16/1997 | 1600 |
05/12/1998 | 2100 | 05/12/1998 | 2130 |
11/11/1998 | 1400 | 11/11/1998 | 1800 |
03/30/1999 | 1845 | 03/30/1999 | 1940 |
12/07/1999 | 2009 | 12/07/1999 | 2100 |
05/09/2000 | 1800 | 05/09/2000 | 1845 |
09/26/2000 | 2000 | 09/26/2000 | 2100 |
Subject: | SGP/SMOS/E7 - 6-month Calibration Checks |
DataStreams: | sgp1smosE7.a0, sgp30smosE7.a1, sgp1440smosE7.a0 |
Description: | During the time periods specified, the SMOS.E7 tower was lowered for 6-month Calibration Checks. During these times wind data are incorrect and temperature and humidity data may be incorrect. Note, exact times when tower was down or maintenance was being performed is sometimes unknown. Users should use the remaining data from these days with caution. |
Measurements: | sgp30smosE7.a1:
sgp1smosE7.a0:
sgp1440smosE7.a0:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
06/15/1994 | 1525 | 06/15/1994 | 1725 |
11/16/1994 | 1458 | 11/16/1994 | 1658 |
04/19/1995 | 1717 | 04/19/1995 | 1818 |
10/02/1995 | 1940 | 10/02/1995 | 2215 |
04/17/1996 | 1400 | 04/17/1996 | 1730 |
10/30/1996 | 1550 | 10/30/1996 | 1730 |
04/29/1997 | 1930 | 04/29/1997 | 2000 |
10/28/1997 | 2000 | 10/28/1997 | 2300 |
10/29/1997 | 1815 | 10/29/1997 | 1910 |
04/28/1998 | 2035 | 04/28/1998 | 2110 |
11/23/1998 | 1900 | 11/23/1998 | 1940 |
04/27/1999 | 1735 | 04/27/1999 | 2300 |
09/28/1999 | 1910 | 09/28/1999 | 1930 |
04/25/2000 | 1636 | 04/25/2000 | 1707 |
10/24/2000 | 1648 | 10/24/2000 | 1800 |
Subject: | SGP/SMOS/E8 - 6-month Calibration Checks |
DataStreams: | sgp1smosE8.a0, sgp30smosE8.a1, sgp1440smosE8.a0 |
Description: | During the time periods specified, the SMOS.E8 tower was lowered for 6-month Calibration Checks. During these times wind data are incorrect and temperature and humidity data may be incorrect. Note, exact times when tower was down or maintenance was being performed is sometimes unknown. Users should use the remaining data from these days with caution. |
Measurements: | sgp30smosE8.a1:
sgp1440smosE8.a0:
sgp1smosE8.a0:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
02/24/1995 | 0000 | 03/31/2001 | 2359 |
Subject: | SGP/SMOS/E7 - Reprocess: Wind direction offset |
DataStreams: | sgp1smosE7.a0, sgp30smosE7.a1 |
Description: | When the SGP.E7 SMOS tower was installed it was not aligned properly resulting in a 6 degree offset. On 3/08/05, the datalogger program was modified to correct for this offset. |
Measurements: | sgp30smosE7.a1:
sgp1smosE7.a0:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
06/23/1999 | 2351 | 07/06/1999 | 1809 |
Subject: | SGP/SMOS/E7 - RH values incorrect |
DataStreams: | sgp1smosE7.a0, sgp30smosE7.a1, sgp1440smosE7.a0 |
Description: | RH values were reported at near 0%. All derived values also affected. |
Measurements: | sgp30smosE7.a1:
sgp1smosE7.a0:
sgp1440smosE7.a0:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
02/25/1995 | 0000 | 04/20/1995 | 2014 |
Subject: | SGP/SMOS/E7 - Reprocess: Incorrect Wind Speed data from SMOS E7 |
DataStreams: | sgp1smosE7.a0, sgp30smosE7.a1, sgp1440smosE7.a0 |
Description: | Editor's Note: A portion of the period of time to which this DQR applies is prior to the begin date of regular ARM data collection. The actual begin date of the problem described in this DQR is 950224.0400. Incorrect Wind Speed calibration factor used at installation. The correct calibration factor was loaded into the data logger on 20 APR 95 at 2014 GMT. |
Measurements: | sgp30smosE7.a1:
sgp1smosE7.a0:
sgp1440smosE7.a0:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
02/25/1995 | 0000 | 05/17/1995 | 1732 |
Subject: | SGP/SMOS/E7 - Questionable Humidity data |
DataStreams: | sgp1smosE7.a0, sgp30smosE7.a1, sgp1440smosE7.a0 |
Description: | Editor's note: A portion of the period of time to which this DQR applies is prior to the begin date of regular ARM data collection. The actual begin date of the problem described in this DQR is 950224.0400. All SMOS E7 humidity data taken during this period are questionable. The sensor was replaced several times. A "good" sensor was finally installed on 17 MAY 95 at 1732 GMT. |
Measurements: | sgp30smosE7.a1:
sgp1smosE7.a0:
sgp1440smosE7.a0:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
05/10/1995 | 0000 | 10/02/1995 | 2215 |
Subject: | SGP/SMOS/E8 - Reprocess: Incorrect wind speed calibration |
DataStreams: | sgp1smosE8.a0, sgp30smosE8.a1, sgp1440smosE8.a0 |
Description: | The wrong data logger program file was loaded into the data logger. The best guess is that this was done when the system was relocated on 10 MAY 95. It was discovered and corrected during the 6 month sensor verification. |
Measurements: | sgp30smosE8.a1:
sgp1440smosE8.a0:
sgp1smosE8.a0:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
02/20/1997 | 2130 | 03/20/1997 | 1600 |
Subject: | SGP/SMOS/E7 - Reprocess: Wind direction incorrect |
DataStreams: | sgp1smosE7.a0, sgp30smosE7.a1 |
Description: | The 10m tower at E7 fell on 20 FEB 97 some time after 2130 GMT. It was returned to service on 13 MAR 97 at 0600 GMT, but the wind monitor was incorrectly installed resulting in wind directions being 180 deg out until it was re-oriented on 20 MAR 97 at 1600 GMT. |
Measurements: | sgp30smosE7.a1:
sgp1smosE7.a0:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/04/1996 | 0000 | 04/16/1997 | 1430 |
Subject: | SGP/SMOS/E7 - Humidity data drifted out of tolerance |
DataStreams: | sgp1smosE7.a0, sgp30smosE7.a1 |
Description: | The humidity data reported by the Elk Falls (E7) SMOS drifted out of tolerance starting on approximately 4 OCT 96. The RH probe started reporting values exceeding 104% RH. The SMOS underwent a 6-month verification check on 13 NOV 96, but the reference RH sensor was not operating properly at the time. At the mentor's request, the T/RH probe was replaced on 4 FEB 97, but the replacement probe was not operating within specifications. Due to lack of calibrated spare probes, the bad replacement T/RH probe was not replaced until 16 APR 97. |
Measurements: | sgp30smosE7.a1:
sgp1smosE7.a0:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
08/05/1997 | 2000 | 09/30/1997 | 2100 |
Subject: | SGP/SMOS/E8 - Reprocess: Incorrect wind directions from E8 SMOS |
DataStreams: | sgp1smosE8.a0, sgp30smosE8.a1 |
Description: | When the Wind Monitor was changed at E8 for scheduled PM, the replacement sensor was incorrectly wired to the data logger. It did not effect the wind speed readings, but wind directions had E and W reversed. Thus winds from 15 deg were reported as being from 345 deg, and vice-versa, and winds from 165 deg were reported as being from 195 degrees, and vice-versa. |
Measurements: | sgp30smosE8.a1:
sgp1smosE8.a0:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
09/02/1997 | 0000 | 09/16/1997 | 0000 |
Subject: | SGP/SMOS/E8 - Questionable E8 SMOS rain data |
DataStreams: | sgp1smosE8.00, sgp1smosE8.a0, sgp30smosE8.a1 |
Description: | The E8 SMOS rain gauge pulse counter was found to be non-operational during the 16 SEP 97 PM. It was repaired by replacing the CR10 wiring harness on 29 OCT 97 at 1815 GMT. |
Measurements: | sgp30smosE8.a1:
sgp1smosE8.00:
sgp1smosE8.a0:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
03/16/1998 | 1400 | 03/17/1998 | 1630 |
Subject: | SGP/SMOS/E8 - Icing affected E8 SMOS wind speed |
DataStreams: | sgp1smosE8.00, sgp1smosE8.a0, sgp30smosE8.a1, sgp1440smosE8.a0 |
Description: | Icing conditions at E8 caused the SMOS wind speed data to be questionable between 1400 and 2130 GMT on 16 MAR 98 and again between 0430 and 1630 GMT on 17 MAR 98. The data appear to be unaffected between those two periods, but may also be questionable. |
Measurements: | sgp30smosE8.a1:
sgp1440smosE8.a0:
sgp1smosE8.00:
sgp1smosE8.a0:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/05/1999 | 1325 | 10/05/1999 | 1350 |
Subject: | SGP/SMOS/E8 - E8 SMOS lowered to surface to install couterweights |
DataStreams: | sgpsmosE8.01, sgp1smosE8.00, sgp1smosE8.a0, sgp30smosE8.a1, sgp1440smosE8.a0 |
Description: | The E8 SMOS was lowered to the surface on 5 OCT 1999 between 1325 and 1350 GMT while counterweights were installed. All temperature and humidity data are questionable during this period. |
Measurements: | sgp30smosE8.a1:
sgpsmosE8.01:
sgp1440smosE8.a0:
sgp1smosE8.00:
sgp1smosE8.a0:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/08/1999 | 0740 | 10/08/1999 | 0755 |
Subject: | SGP/SMOS/E7 - E7 SMOS lowered to surface to install counterweights |
DataStreams: | sgpsmosE7.01, sgp1smosE7.00, sgp1smosE7.a0, sgp30smosE7.a1, sgp1440smosE7.a0 |
Description: | The E7 SMOS was lowered to the surface on 8 OCT 1999 between 0740 and 0755 GMT while counterweights were installed. All temperature and humidity data are questionable during this period. |
Measurements: | sgpsmosE7.01:
sgp30smosE7.a1:
sgp1smosE7.a0:
sgp1440smosE7.a0:
sgp1smosE7.00:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
05/19/1999 | 2125 | 05/27/1999 | 2000 |
Subject: | SGP/SMOS/E6 - E6 SMOS down for tower replacement |
DataStreams: | sgpsmosE6.01, sgp1smosE6.00, sgp1smosE6.a0, sgp30smosE6.a1, sgp1440smosE6.a0 |
Description: | The E6 SMOS was shut down from 19 MAY 1999 at 2125 GMT until 27 MAY 1999 at 2000 GMT while the tower was replaced. |
Measurements: | sgp30smosE6.a1:
sgp1440smosE6.a0:
sgpsmosE6.01:
sgp1smosE6.00:
sgp1smosE6.a0:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
05/19/1999 | 1400 | 06/09/1999 | 1940 |
Subject: | SGP/SMOS/E7 - E7 SMOS down for tower replacement |
DataStreams: | sgpsmosE7.01, sgp1smosE7.00, sgp1smosE7.a0, sgp30smosE7.a1, sgp1440smosE7.a0 |
Description: | The E7 SMOS was shut down from 19 MAY 1999 at 1400 GMT until 9 JUN 1999 at 1940 GMT while the tower was replaced. |
Measurements: | sgpsmosE7.01:
sgp30smosE7.a1:
sgp1smosE7.a0:
sgp1440smosE7.a0:
sgp1smosE7.00:
|