Data Quality Reports for Session: 138105 User: cw101 Completed: 10/18/2011


TABLE OF CONTENTS

DQR IDSubjectData Streams Affected
D060502.2PYE/GNDRAD/M1 - Reprocessed: IRT configuration and calibrationpyegndrad20sM1.a0, pyegndrad60sM1.b1
D060630.44PYE/GNDRAD/M1 - Reprocessed: Longwave calibration errorpyegndrad60sM1.b1


DQRID : D060502.2
Start DateStart TimeEnd DateEnd Time
02/17/2005182103/11/20052032
Subject:
PYE/GNDRAD/M1 - Reprocessed: IRT configuration and calibration
DataStreams:pyegndrad20sM1.a0, pyegndrad60sM1.b1
Description:
The configuration of the IRT was inadvertently set to default and the program of the data 
loggers were changed to that used at TWP.C3.  This caused the calibration of the data to 
be wrong. It was corrected by reconfiguring the IRT and changing the conversion factors 
in the data logger program.

These data have been reprocessed to apply correct calibrations and the reprocessed data 
were archived 20070212.
Measurements:pyegndrad20sM1.a0:
  • inst_sfc_ir_signal

pyegndrad60sM1.b1:
  • Surface Infra-Red Temperature Maxima(sfc_ir_temp_max)
  • Surface Infra-Red Temperature Minima(sfc_ir_temp_min)
  • sfc_ir_temp_std
  • Effective Surface (Skin) Temperature(sfc_ir_temp)


Back To Table of Contents

DQRID : D060630.44
Start DateStart TimeEnd DateEnd Time
02/01/2005000009/14/20050000
Subject:
PYE/GNDRAD/M1 - Reprocessed: Longwave calibration error
DataStreams:pyegndrad60sM1.b1
Description:
Modified pyrgeometer calibration procedures were implemented beginning in December 2003. 
These modified procedures introduced a calibration bias in the longwave data.  The 
previous procedures were re-implemented at all sites between December 2005 and February 2006 to 
restore proper calibrations.

The data collected while the incorrect procedures were in place have been reprocessed to 
remove the calibration bias.  The reprocessed 60 second averaged data are based on 3 
instantaneous 20 second data records rather than on 60 1 second instantaneous data records. 
Still, these data are considered far superior to the originally processed data. The 
reprocessed data were archived in February 2007.
Measurements:pyegndrad60sM1.b1:
  • Radiation, longwave, at 10-m height, upwelling hemispheric irrad., 1-min avg(up_long_hemisp)


Back To Table of Contents



END OF DATA