DQR ID | Subject | Data Streams Affected |
---|---|---|
D000211.10 | SGP/EBBR - EBBR E20 Data Incorrect from SHF #5 | sgp30ebbrE20.b1, sgp15ebbrE20.b1 |
D000211.12 | SGP/EBBR - EBBR E20 Thermocouple Data Incorrect | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
D000225.4 | SGP/EBBR - EBBR E18 Right Humidity Incorrect | sgp15ebbrE18.b1, sgp30ebbrE18.b1, sgp5ebbrE18.b1 |
D000225.5 | SGP/EBBR - EBBR E18 Data Incorrect After Lightning Strike | sgp15ebbrE18.b1, sgp30ebbrE18.b1, sgp5ebbrE18.b1 |
D000225.6 | SGP/EBBR - EBBR E18 Much Data Missing After Lightning Strike | sgp15ebbrE18.b1, sgp30ebbrE18.b1, sgp5ebbrE18.b1 |
D000228.1 | SGP/EBBR - EBBR E20 Right Air Temperature Incorrect | sgp30ebbrE20.b1, sgp5ebbrE20.b1, sgp15ebbrE20.b1 |
D000301.4 | SGP/EBBR - EBBR E18 Net Radiation Incorrect | sgp15ebbrE18.b1, sgp30ebbrE18.b1, sgp5ebbrE18.b1 |
D000303.1 | SGP/EBBR - EBBR E20 Left Air Temperature Incorrect | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
D010213.4 | SGP/EBBR/E18 - EBBR E18 Wind Speed Iced | sgp15ebbrE18.b1, sgp5ebbrE18.b1, sgp30ebbrE18.b1 |
D010213.5 | SGP/EBBR/E18 - EBBR E18 Wind Speed Iced | sgp5ebbrE18.b1, sgp30ebbrE18.b1, sgp15ebbrE18.b1 |
D010213.7 | SGP/EBBR/E20 - EBBR E20 Wind Speed Iced | sgp30ebbrE20.b1, sgp15ebbrE20.b1, sgp5ebbrE20.b1 |
D010416.10 | SGP/EBBR/E18 - E18 EBBR Data Incorrect | sgp30ebbrE18.b1, sgp15ebbrE18.b1, sgp5ebbrE18.b1 |
D010416.11 | SGP/EBBR/E18 - E18 EBBR Right RH Incorrect | sgp30ebbrE18.b1, sgp5ebbrE18.b1, sgp15ebbrE18.b1 |
D010416.12 | SGP/EBBR/E18 - E18 EBBR Thum Right Incorrect | sgp30ebbrE18.b1, sgp15ebbrE18.b1, sgp5ebbrE18.b1 |
D010416.8 | SGP/EBBR/E18 - E18 EBBR Data Incorrect | sgp30ebbrE18.b1, sgp15ebbrE18.b1, sgp5ebbrE18.b1 |
D010416.9 | SGP/EBBR/E18 - E18 EBBR Data Incorrect | sgp30ebbrE18.b1, sgp15ebbrE18.b1, sgp5ebbrE18.b1 |
D010427.1 | SGP EBBR E18 - E18 EBBR Wind Direction Frozen | sgp30ebbrE18.b1, sgp15ebbrE18.b1, sgp5ebbrE18.b1 |
D010427.2 | SGP EBBR E18 - E18 EBBR Wind Direction Frozen | sgp30ebbrE18.b1, sgp15ebbrE18.b1, sgp5ebbrE18.b1 |
D010427.3 | SGP EBBR E18 - E18 EBBR Left Ventilator Fan Not Working | sgp30ebbrE18.b1, sgp5ebbrE18.b1, sgp15ebbrE18.b1 |
D010517.1 | SGP EBBR E20 - E20 EBBR Soil Heat Flow #3 Incorrect | sgp15ebbrE20.b1, sgp30ebbrE20.b1 |
D010517.2 | SGP EBBR E20 - E20 EBBR Right Air T Incorrect | sgp5ebbrE20.b1, sgp30ebbrE20.b1, sgp15ebbrE20.b1 |
D010517.3 | SGP EBBR E20 - E20 EBBR Right Air T Incorrect | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
D010605.11 | SGP EBBR E20 - E20 EBBR Soil Temperatures Incorrect | sgp30ebbrE20.b1, sgp15ebbrE20.b1 |
D010605.12 | SGP EBBR E20 - E20 EBBR Data Incorrect During STP #3 Replacement | sgp30ebbrE20.b1, sgp15ebbrE20.b1, sgp5ebbrE20.b1, sgp5ebbrE20.00 |
D010605.13 | SGP EBBR E20 - E20 EBBR Data Incorrect After Program Restart | sgp30ebbrE20.b1, sgp15ebbrE20.b1, sgp5ebbrE20.b1, sgp5ebbrE20.00 |
D010605.14 | SGP EBBR E20 - E20 EBBR Some Data Incorrect | sgp30ebbrE20.b1 |
D010605.7 | SGP EBBR E20 - E20 EBBR Data Incorrect | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1, sgp5ebbrE20.00 |
D010605.8 | SGP EBBR E20 - E20 EBBR Data Incorrect | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1, sgp5ebbrE20.00 |
D010605.9 | SGP EBBR E20 - E20 EBBR Net Radiation Data Incorrect | sgp30ebbrE20.b1, sgp5ebbrE20.b1, sgp15ebbrE20.b1 |
D011127.29 | SGP EBBR E18 - E18 EBBR Data Incorrect During 6 Month Checks | sgp5ebbrE18.b1, sgp30ebbrE18.b1, sgp15ebbrE18.b1 |
D011127.31 | SGP EBBR E20 - E20 EBBR Data Incorrect During 6 Month Checks | sgp30ebbrE20.b1, sgp15ebbrE20.b1, sgp5ebbrE20.b1 |
D011127.4 | SGP EBBR E20 - E20 EBBR Soil Temperature #3 Incorrect | sgp30ebbrE20.b1, sgp15ebbrE20.b1 |
D011218.10 | SGP EBBR E20 - E20 EBBR Soil Heat Flow #2 Incorrect | sgp30ebbrE20.b1, sgp15ebbrE20.b1 |
D011218.11 | SGP EBBR E20 - E20 EBBR Battery Voltage Low, Incorrect Data | sgp15ebbrE20.b1, sgp30ebbrE20.b1 |
D011218.13 | SGP EBBR E20 - E20 EBBR Battery Voltage Low, Data Incorrect | sgp15ebbrE20.b1, sgp30ebbrE20.b1 |
D011218.14 | SGP/EBBR/E20 - Reprocess: Soil Temperature #3 Incorrect | sgp15ebbrE20.b1, sgp30ebbrE20.b1 |
D011218.5 | SGP EBBR E18 - E18 EBBR AEM Frozen, Data Incorrect | sgp30ebbrE18.b1, sgp5ebbrE18.b1, sgp15ebbrE18.b1 |
D011218.6 | SGP EBBR E18 - E18 EBBR Wind Direction Frozen, Data Incorrect | sgp5ebbrE18.b1, sgp15ebbrE18.b1, sgp30ebbrE18.b1 |
D011218.7 | SGP EBBR E18 - E18 EBBR Wind Speed Frozen, Data Incorrect | sgp15ebbrE18.b1, sgp5ebbrE18.b1, sgp30ebbrE18.b1 |
D011218.8 | SGP EBBR E18 - E18 EBBR Right RH Incorrect | sgp30ebbrE18.b1, sgp5ebbrE18.b1, sgp15ebbrE18.b1 |
D011218.9 | SGP EBBR E20 - E20 EBBR Soil Heat Flow #4 Incorrect | sgp30ebbrE20.b1, sgp15ebbrE20.b1 |
D020628.18 | SGP/EBBR/E20 - T/RH Check | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
D020628.4 | SGP/EBBR/E20 - 3-month Check | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
D020716.14 | SGP/EBBR/E18 - 6 Month Checks | sgp15ebbrE18.b1, sgp30ebbrE18.b1, sgp5ebbrE18.b1 |
D020716.16 | SGP/EBBR/E20 - 6 Month Checks | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
D020717.20 | SGP/EBBR/E18 - Version 6 Produced Noisy Fluxes | sgp30ebbrE18.b1 |
D020717.21 | SGP/EBBR/E18 - AEM Hung | sgp15ebbrE18.b1, sgp30ebbrE18.b1, sgp5ebbrE18.b1 |
D020717.22 | SGP/EBBR/E18 - Soil Heat Flows Incorrect After Calibration Changeout | sgp30ebbrE18.b1 |
D020717.23 | SGP/EBBR/E18 - Reprocess: Soil Heat Flow #1 Incorrect | sgp30ebbrE18.b1 |
D020717.24 | SGP/EBBR/E18 - Left Air Temperature Incorrect | sgp15ebbrE18.b1, sgp30ebbrE18.b1, sgp5ebbrE18.b1 |
D020717.25 | SGP/EBBR/E18 - Reference Temperature Incorrect | sgp15ebbrE18.b1, sgp30ebbrE18.b1, sgp5ebbrE18.b1 |
D020717.40 | SGP/EBBR/E20 - AEM Hung | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
D020717.42 | SGP/EBBR/E20 - Battery Voltage Low | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.00, sgp5ebbrE20.b1 |
D020717.43 | SGP/EBBR/E20 - Pressure Almost Constant | sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
D020717.45 | SGP/EBBR/E20 - Reprocess: Soil Heat Flow #3 Incorrect During Sensor Changeout | sgp30ebbrE20.b1 |
D020717.46 | SGP/EBBR/E20 - Reprocess: Soil Heat Flow #2 Has a Negative Offset | sgp30ebbrE20.b1 |
D020717.47 | SGP/EBBR/E20 - Reprocess: Soil Heat Flow #4 Incorrect | sgp30ebbrE20.b1 |
D020717.48 | SGP/EBBR/E20 - Measurements Zero | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.00, sgp5ebbrE20.b1 |
D020717.49 | SGP/EBBR/E20 - Reprocess: Soil Temperature #3 Incorrect | sgp30ebbrE20.b1 |
D020717.50 | SGP/EBBR/E20 - Measurements Incorrect During Sensor Changeout | sgp30ebbrE20.b1 |
D020717.51 | SGP/EBBR/E20 - Measurements Incorrect | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.00, sgp5ebbrE20.b1 |
D020726.1 | SGP/EBBR/E20 - Reprocess: Soil Heat Flow #2 and #4 incorrect | sgp30ebbrE20.b1 |
D021113.1 | SGP/EBBR - Incorrect Units for Soil Heat Capacity (cs1, cs2, cs3, cs4, cs5) in 30EBBR Header | sgp30ebbrE12.b1, sgp30ebbrE13.b1, sgp30ebbrE15.b1, sgp30ebbrE18.b1, sgp30ebbrE19.b1, sgp30ebbrE2.b1, sgp30ebbrE20.b1, sgp30ebbrE22.b1, sgp30ebbrE26.b1, sgp30ebbrE4.b1, sgp30ebbrE7.b1, sgp30ebbrE8.b1, sgp30ebbrE9.b1 |
D021113.4 | SGP/EBBR - Incorrect Units for Soil Heat Capacity (cs1, cs2, cs3, cs4, cs5) in 30EBBR Header | sgp30ebbrE12.b1, sgp30ebbrE13.b1, sgp30ebbrE15.b1, sgp30ebbrE20.b1, sgp30ebbrE22.b1, sgp30ebbrE26.b1, sgp30ebbrE4.b1, sgp30ebbrE7.b1, sgp30ebbrE8.b1, sgp30ebbrE9.b1 |
D030110.23 | SGP/EBBR/E18 - Data Incorrect during 6 month checks | sgp15ebbrE18.b1, sgp30ebbrE18.b1, sgp5ebbrE18.b1 |
D030110.25 | SGP/EBBR/E20 - Data Incorrect during 6 month checks | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
D030115.10 | SGP/EBBR/E18 - Reprocess: Soil Heat Flow #1 High | sgp30ebbrE18.b1 |
D030115.11 | SGP/EBBR/E18 - Reprocess: Soil Heat Flow #4 High | sgp30ebbrE18.b1 |
D030115.12 | SGP/EBBR/E18 - Data Mostly Zero Following Logger Restart | sgp15ebbrE18.b1, sgp30ebbrE18.b1, sgp5ebbrE18.b1 |
D030115.13 | SGP/EBBR/E18 - Data Incorrect After Logger Restart | sgp30ebbrE18.b1 |
D030115.14 | SGP/EBBR/E18 - Water in Net Radiometer Dome | sgp30ebbrE18.b1 |
D030117.10 | SGP/EBBR/E20 - Data Zero following logger restarts | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
D030117.11 | SGP/EBBR/E20 - REPROCESS: Soil Temperature #2 Incorrect | sgp30ebbrE20.b1 |
D030117.12 | SGP/EBBR/E20 - Change of Energy Storage Incorrect | sgp30ebbrE20.b1 |
D030117.13 | SGP/EBBR/E20 - Battery voltage low | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
D030117.14 | SGP/EBBR/E20 - Wind speed and direction frozen | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE2.b1 |
D030117.18 | SGP/EBBR/E20 - AEM Hung between Home Positions | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
D030117.19 | SGP/EBBR/E20 - REPROCESS: Heat Flow #3 and #5 Incorrect | sgp30ebbrE20.b1 |
D030117.2 | SGP/EBBR/E20 - Data incorrect during instrument maintenance | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
D030117.20 | SGP/EBBR/E20 - REPROCESS: Soil Heat Flow #5 Incorrect | sgp30ebbrE20.b1 |
D030117.22 | SGP/EBBR/E20 - REPROCESS: Soil Temperature #1 Incorrect | sgp30ebbrE20.b1 |
D030117.24 | SGP/EBBR/E18 - REPROCESS: Soil Heat Flow #1 and #4 High | sgp30ebbrE18.b1 |
D030117.25 | SGP/EBBR/E20 - REPROCESS: Soil Temperature #3 Incorrect | sgp30ebbrE20.b1 |
D030117.3 | SGP/EBBR/E20 - Resistance-based Measurements Incorrect | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
D030117.8 | SGP/EBBR/E20 - REPROCESS: Net Rad Coefficients Incorrect | sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
D030121.1 | SGP/EBBR/E20 - REPROCESS: Soil Temperature #1 and Soil Heat Flow #5 Incorrect | sgp30ebbrE20.b1 |
D030711.10 | SGP/EBBR/E20 - RHtop Zero | sgp30ebbrE20.b1 |
D030711.22 | SGP/EBBR/E18 - AEM Hung | sgp15ebbrE18.b1, sgp30ebbrE18.b1, sgp5ebbrE18.b1 |
D030711.8 | SGP/EBBR/E20 - Soil Heat Flow#5 Incorrect | sgp15ebbrE20.b1, sgp30ebbrE20.b1 |
D030711.9 | SGP/EBBR/E20 - Soil Storage Incorrect After Startup | sgp30ebbrE20.b1 |
D030712.19 | SGP/EBBR/E18 - 6 Month Checks | sgp15ebbrE18.b1, sgp30ebbrE18.b1, sgp5ebbrE18.b1 |
D030712.21 | SGP/EBBR/E20 - 6 Month Checks | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
D030919.9 | SGP/EBBR/E18 - Water in Net Radiometer; Surface Fluxes are Incorrect | sgp30ebbrE18.b1, sgp5ebbrE18.b1, sgp15ebbrE18.b1 |
D031029.1 | SGP/EBBR/E20 - Fuse Blown in AEM | sgp30ebbrE20.b1, sgp15ebbrE20.b1, sgp5ebbrE20.b1 |
D031029.2 | SGP/EBBR/E20 - Reprocess: Soil Temperature Probe #1 Measurements Spiked | sgp15ebbrE20.b1, sgp30ebbrE20.b1 |
D031031.7 | SGP/EBBR/E20 - Water in Net Radiometer, Surface Fluxes Incorrect | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
D031204.16 | SGP/EBBR/E18 - 6 Month Checks | sgp15ebbrE18.b1, sgp30ebbrE18.b1, sgp5ebbrE18.b1 |
D031204.19 | SGP/EBBR/E20 - 6 Month Checks | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
D031208.5 | SGP/EBBR/E20 - Wind Direction Incorrect | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
D031211.5 | SGP/EBBR/E20 - Pressure Sensor Data Incorrect | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
D031222.20 | SGP/EBBR/E20 - Wind Speed Sensor Frozen By Ice Storm | sgp30ebbrE20.b1, sgp5ebbrE20.b1, sgp15ebbrE20.b1 |
D040206.1 | SGP/EBBR/E18 - AEM Sitting At Home 15 Position | sgp30baebbrE18.c1, sgp30ebbrE18.b1, sgp5ebbrE18.b1, sgp15ebbrE18.b1 |
D040304.17 | SGP/EBBR/E18 - Wind Speed Frozen Stopped By Ice | sgp15ebbrE18.b1, sgp30ebbrE18.b1, sgp5ebbrE18.b1 |
D040304.18 | SGP/EBBR/E18 - Wind Direction Frozen Stopped By Ice | sgp30ebbrE18.b1, sgp5ebbrE18.b1 |
D040304.19 | SGP/EBBR/E20 - Wind Speed Frozen Stopped By Ice | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
D040304.20 | SGP/EBBR/E20 - Wind Direction Frozen Stopped By Ice | sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
D040505.3 | SGP/EBBR/E18 - Pressure Low | sgp30ebbrE18.b1, sgp5ebbrE18.b1 |
D040507.2 | SGP/EBBR/E20 - Left Air Temperature Incorrect | sgp15ebbrE20.b1, sgp30baebbrE20.c1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
D040722.1 | SGP/EBBR/E20 - Wind Direction Stuck at 100 Degrees | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
D040723.4 | SGP/EBBR/E18 - Soil Temperature and Moisture Probes in Set #1 Spiked Outputs | sgp30ebbrE18.b1 |
D040813.2 | SGP/EBBR/E20 - AEM Failure | sgp5ebbrE20.b1, sgp15ebbrE20.b1, sgp30ebbrE20.b1 |
D040813.6 | SGP/EBBR/E18 - Soil Temperature #2 Incorrect | sgp30ebbrE18.b1 |
D040915.7 | SGP/EBBR/E20 - Soil Heat Flow #3 and Soil Temperature #3 Incorrect | sgp15ebbrE20.b1, sgp30ebbrE20.b1 |
D041006.3 | SGP/EBBR/E20 - All Soil Measurements Incorrect | sgp15ebbrE20.b1, sgp30ebbrE20.b1 |
D041222.14 | SGP/EBBR/E18 - 6 Month Checks | sgp15ebbrE18.b1, sgp30ebbrE18.b1, sgp5ebbrE18.b1 |
D041222.16 | SGP/EBBR/E20 - 6 Month Checks | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
D041222.3 | SGP/EBBR/E20 - Soil Moisture #4 and Soil Temperature #4 Incorrect | sgp15ebbrE20.b1, sgp30ebbrE20.b1 |
D041223.1 | SGP/EBBR/E20 - Soil Heat Flow #4 Incorrect | sgp15ebbrE20.b1, sgp30ebbrE20.b1 |
D050206.12 | SGP/EBBR/E18 - Wind Speed Frozen Stopped By Ice Storm | sgp15ebbrE18.b1, sgp30ebbrE18.b1, sgp5ebbrE18.b1 |
D050206.14 | SGP/EBBR/E20 - Wind Speed Frozen Stopped By Ice Storm | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
D050207.10 | SGP/EBBR/E20 - Wind Direction Frozen Stopped By Ice Storm | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
D050207.8 | SGP/EBBR/E18 - Wind Direction Frozen Stopped By Ice Storm | sgp30ebbrE18.b1, sgp5ebbrE18.b1, sgp15ebbrE18.b1 |
D050404.1 | SGP/EBBR/E20 - Wrong Datalogger Program Installed | sgp30ebbrE20.b1 |
D050404.4 | SGP/EBBR/E20 - Temp. of thum_left Incorrect At Times | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
D050719.11 | SGP/EBBR/E18 - Improved EBBR CR10 Program | sgp30ebbrE18.b1 |
D050719.13 | SGP/EBBR/E20 - Improved EBBR CR10 Program | sgp30ebbrE20.b1 |
D050922.2 | SGP/EBBR/E20 - Soil Temperature and Soil Moisture #4 Measurements Incorrect | sgp15ebbrE20.b1, sgp30ebbrE20.b1 |
D051106.10 | SGP/EBBR/E18 - Net Radiation Incorrect; Sensible and Latent Heat Fluxes Incorrect | sgp15ebbrE18.b1, sgp30ebbrE18.b1, sgp5ebbrE18.b1 |
D051106.26 | SGP/EBBR/E18 - Average Soil Heat Flux Incorrect | sgp30ebbrE18.b1 |
D051106.28 | SGP/EBBR/E20 - Average Soil Heat Flux Incorrect | sgp30ebbrE20.b1 |
D051111.13 | SGP/EBBR/E18 - metadata corrections | sgp15ebbrE18.b1, sgp30ebbrE18.b1, sgp5ebbrE18.b1 |
D051112.7 | SGP/EBBR/E20 - metadata corrections | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
D060111.13 | SGP/EBBR/E20 - Data Incorrect During J-Panel Replacement | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
D060501.17 | SGP/EBBR/E18 - Wind Speed Zero | sgp15ebbrE18.b1, sgp30ebbrE18.b1, sgp5ebbrE18.b1 |
D060501.22 | SGP/EBBR/E20 - Suspect Measurements | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
D060622.6 | SGP/EBBR/E20 - Net Radiation, Fluxes Too Large | sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
D060818.6 | SGP/EBBR/E18 - Sensible and Latent Heat Fluxes and Net Radiation Incorrect | sgp15ebbrE18.b1, sgp30ebbrE18.b1, sgp5ebbrE18.b1 |
D061103.3 | SGP/EBBR/E18 - Sensible and Latent Heat Fluxes Incorrect | sgp30ebbrE18.b1 |
D061220.10 | SGP/EBBR/E18 - Wind Direction Dependency of Surface Fluxes and General Data Quality Information | sgp30ebbrE18.b1 |
D061220.12 | SGP/EBBR/E20 - Wind Direction Dependency of Surface Fluxes and General Data Quality Information | sgp30ebbrE20.b1 |
D070716.2 | SGP/EBBR/E20 - Reprocess: Wind Direction 20 Degrees Low | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
D071115.1 | SGP/EBBR/E20 - Reprocess: Wind Direction 65 Degrees Low | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
D080410.2 | SGP/EBBR/E20 - Wind Direction 50 Degrees High | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
D080424.1 | SGP/EBBR/E18 - Soil Heat Flow #4 Offscale Low; Sensible and Latent Heat Flux Sometimes Incorrect | sgp15ebbrE18.b1, sgp30ebbrE18.b1 |
D080702.2 | SGP/EBBR/E18 - SHF #4 Measurements Too Low; Sensible and Latent Heat Fluxes Suspect | sgp15ebbrE18.b1, sgp30ebbrE18.b1 |
D080902.1 | SGP/EBBR/E20 - Wind Direction Incorrect | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
D090313.16 | SGP/EBBR/E20 - Wind Speed Incorrect | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
D090313.3 | SGP/EBBR/E18 - Wind Speed Incorrect | sgp15ebbrE18.b1, sgp30ebbrE18.b1, sgp5ebbrE18.b1 |
D090414.1 | SGP/EBBR/E20 - Wind Direction Incorrect | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
D100202.4 | SGP/EBBR/E20 - Wind speed sensor frozen stopped | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
D100803.1 | SGP/EBBR/E20 - Incorrect Sensible and Latent Heat Fluxes | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
D100816.1 | SGP/EBBR/E20 - Incorrect Sensible and Latent Heat Fluxes - a result of low battery voltage. | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
D111026.2 | SGP/EBBR/E20 - Sensible and latent heat fluxes overestimated | sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
D120229.1 | SGP/EBBR/E36 - Missing Data | sgp15ebbrE36.b1, sgp30ebbrE36.b1, sgp5ebbrE36.b1 |
D120319.1 | SGP/EBBR/E36 - Sensible and Latent Heat Fluxes Incorrect | sgp15ebbrE36.b1, sgp30ebbrE36.b1 |
D120411.3 | SGP/EBBR/E32 - Sensible and latent heat fluxes incorrect | sgp30ebbrE32.b1 |
D930503.1 | EBBR - soil heat flux plate giving opposite sign | sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
D940105.2 | SGP/EBBR/E20 - Blown fuse in AEM at E20 | sgp30ebbrE20.b1, sgp5ebbrE20.b1, sgp15ebbrE20.b1 |
D940105.8 | SGP/EBBR/E20 - Reprocess: Questionable data in soil heat fluxes at E20 | sgp30ebbrE20.b1, sgp15ebbrE20.b1 |
D940329.2 | SGP/EBBR/E20 - Pressure Sensor Malfunction | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
D940616.4 | SGP/EBBR/E20 - Soil Moisture Probe | sgp15ebbrE20.b1, sgp30ebbrE20.b1 |
D940921.1 | SGP/EBBR/E20 - Fan Stopped, T and RH Biases | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
D941021.1 | SGP/EBBR/E20 - Soil Moisture Probe Failure | sgp15ebbrE20.b1, sgp30ebbrE20.b1 |
D941021.2 | SGP/EBBR/E20 - Aspirator Fan Stoppage | sgp15ebbrE20.b1, sgp30ebbrE20.b1 |
D941021.7 | SGP/EBBR/E20 - Net Radiometer Hemisphere Changes | sgp30ebbrE20.b1, sgp15ebbrE20.b1, sgp5ebbrE20.b1 |
D941021.9 | SGP/EBBR/E20 - Net Radiometer Hemisphere Changes | sgp30ebbrE20.b1, sgp15ebbrE20.b1, sgp5ebbrE20.b1 |
D950626.4 | SGP/EBBR/E20 - Frozen Wind Speed Sensor | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
D950803.2 | SGP/EBBR/E20 - Reprocess: Soil Temperature Malfunction | sgp15ebbrE20.b1, sgp30ebbrE20.b1 |
D950815.3 | SGP/EBBR/E20 - Annual Calibration Changeout | sgp30ebbrE20.b1 |
D950816.4 | SGP/EBBR/E20 - AEM Home 30 Values Low | sgp5ebbrE20.b1, sgp30ebbrE20.b1 |
D951116.2 | SGP/EBBR/E20 - Soil Heat Flow Zero Under Unchanging Conditions | sgp30ebbrE20.b1 |
D951116.6 | SGP/EBBR/E20 - AEM Exchange Stopped in Snow and Freezing Rain | sgp30ebbrE20.b1 |
D960502.1 | SGP/EBBR/E20 - Temperature/RH Probes Malfunction and Replacement | sgp30ebbrE20.b1, sgp5ebbrE20.b1, sgp15ebbrE20.b1, sgp5ebbrE20.00 |
D960508.8 | SGP/EBBR/E20 - 3-month check | sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
D961122.17 | SGP/EBBR/E20 - Incorrect Data from Left Humidity Probe | sgp30ebbrE20.b1, sgp15ebbrE20.b1 |
D961122.26 | SGP/EBBR/E20 - EBBR 3 Month Checks - 10 EFs | sgp30ebbrE20.b1, sgp15ebbrE20.b1, sgp5ebbrE20.b1 |
D970330.5 | SGP/EBBR/E20 - Wind Speed Cups Frozen | sgp30ebbrE20.b1, sgp5ebbrE20.b1, sgp15ebbrE20.b1 |
D970729.1 | SGP/EBBR/E20 - Reprocess: E20 Soil Probes #3 Cables Cut | sgp15ebbrE20.b1, sgp30ebbrE20.b1 |
D971021.7 | SGP/EBBR/E20 - EBBR Biannual Checks | sgp30ebbrE20.b1, sgp15ebbrE20.b1, sgp5ebbrE20.b1 |
D971027.6 | SGP/EBBR/E18 - Left RH Probe Temperature Incorrect | sgp15ebbrE18.b1, sgp30ebbrE18.b1 |
D980117.20 | SGP/EBBR/E20- EBBR Frozen Wind Speed | sgp5ebbrE20.b1, sgp30ebbrE20.b1, sgp15ebbrE20.b1 |
D980117.28 | SGP/EBBR/E20 - EBBR AEMs Not Exchanging (Iced Or Fuse Blown) | sgp30ebbrE20.b1, sgp5ebbrE20.b1, sgp15ebbrE20.b1 |
D980410.10 | SGP/EBBR/E20 - Wind Speed Sensor Frozen | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1, sgp5ebbrE20.00 |
D980416.14 | SGP/EBBR/E18 - 3 Month Check | sgp15ebbrE18.b1, sgp30ebbrE18.b1, sgp5ebbrE18.b1 |
D980416.16 | SGP/EBBR/E20 - 3 Month Check | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
D980529.12 | SGP/EBBR/E18 - Six Month Checks | sgp15ebbrE18.b1, sgp30ebbrE18.b1, sgp5ebbrE18.b1 |
D980529.14 | SGP/EBBR/E20 - Six Month Checks | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
D980623.2 | SGP/EBBR/E18 - Reprocess: E18 EBBR Net Radiometer Calibration | sgp30ebbrE18.b1, sgp5ebbrE18.b1 |
D980731.2 | SGP/EBBR/E20 - Wind Speed Incorrect | sgp5ebbrE20.b1, sgp15ebbrE20.b1, sgp30ebbrE20.b1 |
D981113.1 | SGP/EBBR/E20 - Incorrect Data - Cattle Vandalism | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
D990127.10 | SGP/EBBR/E18 - Water In Net Radiometer, Flux Data Incorrect | sgp15ebbrE18.b1, sgp30ebbrE18.b1, sgp5ebbrE18.b1 |
D990127.23 | SGP/EBBR/E18 - Wind Direction Data Incorrect (revised) | sgp15ebbrE18.b1, sgp30ebbrE18.b1, sgp5ebbrE18.b1, sgp5ebbrE18.00 |
D990127.25 | SGP/EBBR/E20 - Wind Direction Data Incorrect (revised) | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
D990127.29 | SGP/EBBR/E20 - Wind Direction Data Incorrect | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
D990127.37 | SGP/EBBR - EBBR E18 Wind Speed Data Incorrect | sgp15ebbrE18.b1, sgp30ebbrE18.b1, sgp5ebbrE18.b1, sgp5ebbrE18.00 |
D990127.38 | SGP/EBBR/E18 - Wind Speed Data Incorrect | sgp15ebbrE18.b1, sgp30ebbrE18.b1, sgp5ebbrE18.b1, sgp5ebbrE18.00 |
D990127.39 | SGP/EBBR/E18 - Wind Speed Data Incorrect | sgp15ebbrE18.b1, sgp30ebbrE18.b1, sgp5ebbrE18.b1, sgp5ebbrE18.00 |
D990127.40 | SGP/EBBR/E20 - Wind Speed Data Incorrect | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
D990127.41 | SGP/EBBR/E20 - Wind Speed Data Incorrect | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
D990129.8 | SGP/EBBR/E20 - Data Incorrect | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1, sgp5ebbrE20.00 |
D990218.2 | SGP/EBBR/E20 - Pressure Low | sgp5ebbrE20.b1, sgp15ebbrE20.b1, sgp30ebbrE20.b1 |
D990415.3 | SGP/EBBR/E20 - Air Temperature Incorrect | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
D990622.2 | SGP/EBBR/E18 - Pressure Incorrect | sgp30ebbrE18.b1, sgp5ebbrE18.b1, sgp5ebbrE18.00 |
Start Date | Start Time | End Date | End Time |
---|---|---|---|
04/07/1999 | 1800 | 04/21/1999 | 1730 |
Subject: | SGP/EBBR - EBBR E20 Data Incorrect from SHF #5 |
DataStreams: | sgp30ebbrE20.b1, sgp15ebbrE20.b1 |
Description: | something, since the problem began during J-panel changeout the 4/7/99 PM. At the 7/21/99 PM, the reference temperature was repaired and reseated. At that time the SHF #5 data became correct again; the two events are probably related only in that other connections, including that of the SHF #5, were probably reseated at the same time. The report of the PM activity is not detailed enough to determine the exact causes and fixes. The incorrect SHF #5 data can be identified by it being an order of magnitude larger than the values from the other soil heat flow sensors. Affected data are: 5 minute: none 15 minute: mv_hft5 30 minute: shf5, c_shf5, g5, ave_shf, e, h |
Measurements: | sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
06/18/1999 | 1715 | 06/18/1999 | 1745 |
Subject: | SGP/EBBR - EBBR E20 Thermocouple Data Incorrect |
DataStreams: | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
Description: | Left and right thermocouple air temperature data are incorrect during the replacement of the right thermocouple. Affected data are: 5 minute: tair_bot, tair_top 15 minute: tai_r, tair_l 30 minute: tair_bot, tair_top, e, h, bowen |
Measurements: | sgp5ebbrE20.b1:
sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
12/03/1999 | 0545 | 01/11/2000 | 2135 |
Subject: | SGP/EBBR - EBBR E18 Right Humidity Incorrect |
DataStreams: | sgp15ebbrE18.b1, sgp30ebbrE18.b1, sgp5ebbrE18.b1 |
Description: | After the 3 December 99 lightning strike, the humidity portion of the right T/RH probe drifted downwards at times, causing vapor pressure gradients to be incorrectly measured. Therefore, sensible and latent heat fluxes were also incorrect. Since much of the data from the period is missing (because of latent effects of the lightning strike), little data is actually affected. The affected data values were: 5 minute: hum_top, hum_bot, vp_top, vp_bot 15 minute: mv_hum_r 30 minute: hum_top, hum_bot, vp_top, vp_bot, bowen, h, e |
Measurements: | sgp15ebbrE18.b1:
sgp30ebbrE18.b1:
sgp5ebbrE18.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
12/03/1999 | 0535 | 12/03/1999 | 0600 |
Subject: | SGP/EBBR - EBBR E18 Data Incorrect After Lightning Strike |
DataStreams: | sgp15ebbrE18.b1, sgp30ebbrE18.b1, sgp5ebbrE18.b1 |
Description: | Immediately after the 3 December 99 lightning strike, all data from this EBBR system was incorrect. The system crashed at the end of this period. |
Measurements: | sgp15ebbrE18.b1:
sgp30ebbrE18.b1:
sgp5ebbrE18.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
12/03/1999 | 0535 | 02/14/2000 | 0915 |
Subject: | SGP/EBBR - EBBR E18 Much Data Missing After Lightning Strike |
DataStreams: | sgp15ebbrE18.b1, sgp30ebbrE18.b1, sgp5ebbrE18.b1 |
Description: | On 3 December 99 this EBBR system was struck by lightning. Much of the data from this EBBR system for the stated period is missing. |
Measurements: | sgp15ebbrE18.b1:
sgp30ebbrE18.b1:
sgp5ebbrE18.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
09/30/1999 | 0700 | 02/09/2000 | 1715 |
Subject: | SGP/EBBR - EBBR E20 Right Air Temperature Incorrect |
DataStreams: | sgp30ebbrE20.b1, sgp5ebbrE20.b1, sgp15ebbrE20.b1 |
Description: | The right air temperature (thermocouple) output was frequently offscale. Examination of the 15 minute data will clearly show which times are affected during the period. The affected data are: 5 minute: tair_top, tair_bot 15 minute: tair_r 30 minute: tair_top, tair_bot, bowen, h, e |
Measurements: | sgp5ebbrE20.b1:
sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
09/21/1999 | 1330 | 09/22/1999 | 0300 |
Subject: | SGP/EBBR - EBBR E18 Net Radiation Incorrect |
DataStreams: | sgp15ebbrE18.b1, sgp30ebbrE18.b1, sgp5ebbrE18.b1 |
Description: | The net radiometer top dome was broken and water had entered. Net radiation values are therefore incorrect during the period. The affected data are: 5 minute: q 15 minute: mv_q 30 minute: q, h, e |
Measurements: | sgp15ebbrE18.b1:
sgp30ebbrE18.b1:
sgp5ebbrE18.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
02/23/2000 | 1935 | 02/23/2000 | 2000 |
Subject: | SGP/EBBR - EBBR E20 Left Air Temperature Incorrect |
DataStreams: | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
Description: | Left air temperature (thermocouple) was incorrect during part of the period, thereby affecting top and bottom air temperature. The affected data and times are: 5 minute: tair_top (1935 GMT) 15 minute: tair_l (1945 GMT) 30 minute: tair_top, bowen, e, h (2000 GMT) |
Measurements: | sgp5ebbrE20.b1:
sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
12/11/2000 | 0930 | 12/15/2000 | 0245 |
Subject: | SGP/EBBR/E18 - EBBR E18 Wind Speed Iced |
DataStreams: | sgp15ebbrE18.b1, sgp5ebbrE18.b1, sgp30ebbrE18.b1 |
Description: | The anemometer was frozen stopped by freezing rain. Indicated data is incorrect. |
Measurements: | sgp15ebbrE18.b1:
sgp30ebbrE18.b1:
sgp5ebbrE18.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
12/25/2000 | 2015 | 01/03/2001 | 1915 |
Subject: | SGP/EBBR/E18 - EBBR E18 Wind Speed Iced |
DataStreams: | sgp5ebbrE18.b1, sgp30ebbrE18.b1, sgp15ebbrE18.b1 |
Description: | The anemometer was frozen stopped by freezing rain. Indicated data is incorrect. |
Measurements: | sgp15ebbrE18.b1:
sgp30ebbrE18.b1:
sgp5ebbrE18.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
12/25/2000 | 1545 | 12/28/2000 | 2145 |
Subject: | SGP/EBBR/E20 - EBBR E20 Wind Speed Iced |
DataStreams: | sgp30ebbrE20.b1, sgp15ebbrE20.b1, sgp5ebbrE20.b1 |
Description: | The anemometer was frozen stopped by freezing rain. Indicated data is incorrect. |
Measurements: | sgp5ebbrE20.b1:
sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
09/19/2000 | 2115 | 09/19/2000 | 2131 |
Subject: | SGP/EBBR/E18 - E18 EBBR Data Incorrect |
DataStreams: | sgp30ebbrE18.b1, sgp15ebbrE18.b1, sgp5ebbrE18.b1 |
Description: | The EBBR data was incorrect during maintenance. |
Measurements: | sgp15ebbrE18.b1:
sgp30ebbrE18.b1:
sgp5ebbrE18.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
02/01/2000 | 0000 | 04/04/2000 | 2131 |
Subject: | SGP/EBBR/E18 - E18 EBBR Right RH Incorrect |
DataStreams: | sgp30ebbrE18.b1, sgp5ebbrE18.b1, sgp15ebbrE18.b1 |
Description: | Right RH being incorrect caused a number of calculated measurements to be incorrect also, including Bowen ratio, and latent and sensible heat fluxes. |
Measurements: | sgp15ebbrE18.b1:
sgp30ebbrE18.b1:
sgp5ebbrE18.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
03/21/2000 | 2300 | 04/04/2000 | 2131 |
Subject: | SGP/EBBR/E18 - E18 EBBR Thum Right Incorrect |
DataStreams: | sgp30ebbrE18.b1, sgp15ebbrE18.b1, sgp5ebbrE18.b1 |
Description: | The temperature portion of the right T/RH probe was not working. Calculated vapor pressure, Bowen ratio, and sensible and latent heat fluxes were also incorrect. |
Measurements: | sgp15ebbrE18.b1:
sgp30ebbrE18.b1:
sgp5ebbrE18.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
04/18/2000 | 2100 | 04/18/2000 | 2101 |
Subject: | SGP/EBBR/E18 - E18 EBBR Data Incorrect |
DataStreams: | sgp30ebbrE18.b1, sgp15ebbrE18.b1, sgp5ebbrE18.b1 |
Description: | The EBBR data was incorrect while the datalogger was being upgraded/replaced. |
Measurements: | sgp15ebbrE18.b1:
sgp30ebbrE18.b1:
sgp5ebbrE18.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
07/28/2000 | 1730 | 07/28/2000 | 1731 |
Subject: | SGP/EBBR/E18 - E18 EBBR Data Incorrect |
DataStreams: | sgp30ebbrE18.b1, sgp15ebbrE18.b1, sgp5ebbrE18.b1 |
Description: | The EBBR data was incorrect just after power was restored. |
Measurements: | sgp15ebbrE18.b1:
sgp30ebbrE18.b1:
sgp5ebbrE18.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
12/11/2000 | 1000 | 12/13/2000 | 1701 |
Subject: | SGP EBBR E18 - E18 EBBR Wind Direction Frozen |
DataStreams: | sgp30ebbrE18.b1, sgp15ebbrE18.b1, sgp5ebbrE18.b1 |
Description: | The wind direction sensor was frozen stopped. The indicated measurements are incorrect as a result. |
Measurements: | sgp15ebbrE18.b1:
sgp30ebbrE18.b1:
sgp5ebbrE18.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
12/26/2000 | 1330 | 12/29/2000 | 1901 |
Subject: | SGP EBBR E18 - E18 EBBR Wind Direction Frozen |
DataStreams: | sgp30ebbrE18.b1, sgp15ebbrE18.b1, sgp5ebbrE18.b1 |
Description: | The wind direction sensor was frozen stopped. The indicated measurements are incorrect as a result. |
Measurements: | sgp15ebbrE18.b1:
sgp30ebbrE18.b1:
sgp5ebbrE18.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
09/12/2000 | 0015 | 09/19/2000 | 2101 |
Subject: | SGP EBBR E18 - E18 EBBR Left Ventilator Fan Not Working |
DataStreams: | sgp30ebbrE18.b1, sgp5ebbrE18.b1, sgp15ebbrE18.b1 |
Description: | The left ventilator fan was not working. Some of the indicated measurements may be incorrect (under some wind speed and direction conditions, cloud cover, and time of day, some of the data may be correct). The data is therefore described as suspect for the indicated period. |
Measurements: | sgp15ebbrE18.b1:
sgp30ebbrE18.b1:
sgp5ebbrE18.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
01/06/2000 | 2000 | 03/06/2000 | 1901 |
03/06/2000 | 1930 | 03/06/2000 | 2031 |
Subject: | SGP EBBR E20 - E20 EBBR Soil Heat Flow #3 Incorrect |
DataStreams: | sgp15ebbrE20.b1, sgp30ebbrE20.b1 |
Description: | Soil Heat Flow #3 was incorrect during the indicated periods. Average soil heat flux, latent heat flux, and sensible heat flux were therefore also incorrect. |
Measurements: | sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
03/22/2000 | 0000 | 05/22/2000 | 0000 |
Subject: | SGP EBBR E20 - E20 EBBR Right Air T Incorrect |
DataStreams: | sgp5ebbrE20.b1, sgp30ebbrE20.b1, sgp15ebbrE20.b1 |
Description: | The right air temperature probe was incorrect while connections for it were checked. Bowen ratio, sensible heat flux, and latent heat flux were incorrect as a result. |
Measurements: | sgp5ebbrE20.b1:
sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
11/02/2000 | 2345 | 02/21/2001 | 1946 |
Subject: | SGP EBBR E20 - E20 EBBR Right Air T Incorrect |
DataStreams: | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
Description: | The right air temperature probe was incorrect frequently. Inspection of the right air temperature data will quickly show where it went offscale. Bowen ratio, sensible heat flux, and latent heat flux were incorrect as a result. |
Measurements: | sgp5ebbrE20.b1:
sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
11/01/2000 | 1930 | 11/01/2000 | 1931 |
Subject: | SGP EBBR E20 - E20 EBBR Soil Temperatures Incorrect |
DataStreams: | sgp30ebbrE20.b1, sgp15ebbrE20.b1 |
Description: | All soil temperatures were incorrect for the indicated period. Latent and sensible heat fluxes were therefore incorrect also. |
Measurements: | sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
11/15/2000 | 2031 | 11/15/2000 | 2101 |
Subject: | SGP EBBR E20 - E20 EBBR Data Incorrect During STP #3 Replacement |
DataStreams: | sgp30ebbrE20.b1, sgp15ebbrE20.b1, sgp5ebbrE20.b1, sgp5ebbrE20.00 |
Description: | All data was incorrect during replacement of soil temperature probe #3. |
Measurements: | sgp5ebbrE20.b1:
sgp5ebbrE20.00:
sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
11/29/2000 | 1831 | 11/29/2000 | 1901 |
Subject: | SGP EBBR E20 - E20 EBBR Data Incorrect After Program Restart |
DataStreams: | sgp30ebbrE20.b1, sgp15ebbrE20.b1, sgp5ebbrE20.b1, sgp5ebbrE20.00 |
Description: | All data was incorrect after a datalogger program restart. |
Measurements: | sgp5ebbrE20.b1:
sgp5ebbrE20.00:
sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
11/29/2000 | 1930 | 11/29/2000 | 1931 |
Subject: | SGP EBBR E20 - E20 EBBR Some Data Incorrect |
DataStreams: | sgp30ebbrE20.b1 |
Description: | Quantities requiring a starting value were incorrect; sensible and latent heat fluxes were therefore incorrect also. |
Measurements: | sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
05/17/2000 | 2001 | 05/17/2000 | 2031 |
Subject: | SGP EBBR E20 - E20 EBBR Data Incorrect |
DataStreams: | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1, sgp5ebbrE20.00 |
Description: | Data was incorrect right after a datalogger upgrade. |
Measurements: | sgp5ebbrE20.b1:
sgp5ebbrE20.00:
sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
07/20/2000 | 1930 | 08/02/2000 | 0331 |
Subject: | SGP EBBR E20 - E20 EBBR Data Incorrect |
DataStreams: | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1, sgp5ebbrE20.00 |
Description: | The data was incorrect because battery voltage was low. |
Measurements: | sgp5ebbrE20.b1:
sgp5ebbrE20.00:
sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/04/2000 | 1930 | 10/04/2000 | 1931 |
Subject: | SGP EBBR E20 - E20 EBBR Net Radiation Data Incorrect |
DataStreams: | sgp30ebbrE20.b1, sgp5ebbrE20.b1, sgp15ebbrE20.b1 |
Description: | The net radiation data was incorrect while the top dome was being replaced. Sensible and latent heat fluxes are therefore also incorrect. |
Measurements: | sgp5ebbrE20.b1:
sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
04/03/2001 | 2255 | 04/03/2001 | 2341 |
10/18/2001 | 1421 | 10/18/2001 | 1601 |
Subject: | SGP EBBR E18 - E18 EBBR Data Incorrect During 6 Month Checks |
DataStreams: | sgp5ebbrE18.b1, sgp30ebbrE18.b1, sgp15ebbrE18.b1 |
Description: | The data was incorrect during the 6 month checks. |
Measurements: | sgp15ebbrE18.b1:
sgp30ebbrE18.b1:
sgp5ebbrE18.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/17/2001 | 1500 | 10/17/2001 | 1601 |
04/04/2001 | 1700 | 04/04/2001 | 1736 |
Subject: | SGP EBBR E20 - E20 EBBR Data Incorrect During 6 Month Checks |
DataStreams: | sgp30ebbrE20.b1, sgp15ebbrE20.b1, sgp5ebbrE20.b1 |
Description: | The data was incorrect during the 6 month checks. |
Measurements: | sgp5ebbrE20.b1:
sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
11/01/2000 | 2300 | 11/15/2000 | 2031 |
Subject: | SGP EBBR E20 - E20 EBBR Soil Temperature #3 Incorrect |
DataStreams: | sgp30ebbrE20.b1, sgp15ebbrE20.b1 |
Description: | The indicated measurements were incorrect while soil temperature probe #3 was not working. |
Measurements: | sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
02/21/2001 | 2000 | 03/07/2001 | 1901 |
Subject: | SGP EBBR E20 - E20 EBBR Soil Heat Flow #2 Incorrect |
DataStreams: | sgp30ebbrE20.b1, sgp15ebbrE20.b1 |
Description: | Broken leads for SHF #2 caused measurements from it to be incorrect during the indicated period. |
Measurements: | sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
03/30/2001 | 0615 | 03/30/2001 | 1431 |
03/31/2001 | 1115 | 03/31/2001 | 1401 |
Subject: | SGP EBBR E20 - E20 EBBR Battery Voltage Low, Incorrect Data |
DataStreams: | sgp15ebbrE20.b1, sgp30ebbrE20.b1 |
Description: | Some measurements were incorrect because the battery voltage was low. |
Measurements: | sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
04/02/2001 | 1245 | 04/02/2001 | 1701 |
04/03/2001 | 0215 | 04/03/2001 | 1501 |
04/06/2001 | 1115 | 04/06/2001 | 1501 |
04/07/2001 | 0345 | 04/07/2001 | 1401 |
04/23/2001 | 1045 | 04/23/2001 | 1331 |
Subject: | SGP EBBR E20 - E20 EBBR Battery Voltage Low, Data Incorrect |
DataStreams: | sgp15ebbrE20.b1, sgp30ebbrE20.b1 |
Description: | The indicated data was incorrect because the battery voltage was low. |
Measurements: | sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
04/15/2001 | 1500 | 10/17/2001 | 0201 |
Subject: | SGP/EBBR/E20 - Reprocess: Soil Temperature #3 Incorrect |
DataStreams: | sgp15ebbrE20.b1, sgp30ebbrE20.b1 |
Description: | During the indicated period, TS #3 was large negative or positive or offscale. Average soil heat flow, sensible heat flux, and latent heat flux were incorrect when TS #3 was incorrect. Inspect the 15 and 30 minute TS #3 data to determine the times of incorrect data. |
Measurements: | sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
02/15/2001 | 0800 | 02/16/2001 | 2031 |
Subject: | SGP EBBR E18 - E18 EBBR AEM Frozen, Data Incorrect |
DataStreams: | sgp30ebbrE18.b1, sgp5ebbrE18.b1, sgp15ebbrE18.b1 |
Description: | The AEM was frozen in one position. The indicated data is incorrect. |
Measurements: | sgp15ebbrE18.b1:
sgp30ebbrE18.b1:
sgp5ebbrE18.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
02/15/2001 | 0625 | 02/16/2001 | 2031 |
02/16/2001 | 2355 | 02/17/2001 | 1650 |
Subject: | SGP EBBR E18 - E18 EBBR Wind Direction Frozen, Data Incorrect |
DataStreams: | sgp5ebbrE18.b1, sgp15ebbrE18.b1, sgp30ebbrE18.b1 |
Description: | The wind direction sensor was frozen stopped. The indicated data is incorrect. |
Measurements: | sgp15ebbrE18.b1:
sgp30ebbrE18.b1:
sgp5ebbrE18.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
02/15/2001 | 0620 | 02/17/2001 | 2006 |
Subject: | SGP EBBR E18 - E18 EBBR Wind Speed Frozen, Data Incorrect |
DataStreams: | sgp15ebbrE18.b1, sgp5ebbrE18.b1, sgp30ebbrE18.b1 |
Description: | The wind speed sensor was frozen stopped. The indicated data are incorrect. |
Measurements: | sgp15ebbrE18.b1:
sgp30ebbrE18.b1:
sgp5ebbrE18.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
05/10/2001 | 1810 | 06/12/2001 | 2240 |
Subject: | SGP EBBR E18 - E18 EBBR Right RH Incorrect |
DataStreams: | sgp30ebbrE18.b1, sgp5ebbrE18.b1, sgp15ebbrE18.b1 |
Description: | The RH portion of the T/RH probe produced incorrect data. Sensible and latent heat fluxes and the Bowen ratio were also incorrect. |
Measurements: | sgp15ebbrE18.b1:
sgp30ebbrE18.b1:
sgp5ebbrE18.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
02/01/2001 | 0000 | 02/22/2001 | 0531 |
03/01/2001 | 1230 | 03/01/2001 | 1231 |
03/07/2001 | 1805 | 03/07/2001 | 1901 |
Subject: | SGP EBBR E20 - E20 EBBR Soil Heat Flow #4 Incorrect |
DataStreams: | sgp30ebbrE20.b1, sgp15ebbrE20.b1 |
Description: | The SHF #4 produced large negative values during much of the period because of a broken lead wire. Inspect the data to determine the times of incorrect SHF #4 values. |
Measurements: | sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
11/10/1994 | 1520 | 11/10/1994 | 1630 |
Subject: | SGP/EBBR/E20 - T/RH Check |
DataStreams: | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
Description: | During the month of November 1994, site operations personnel conducted field comparisons of the temperature and relative humidity sensors in the EBBRs and the HMI31 portable T/RH meter (with the removable probe). As is reflected in the home signal output, the automatic exchange mechanism was disabled in order to conduct the checks. Measurements were taken every 5 minutes, for a half hour each in the aspirated radiation shields (the HMI31 was inserted into the EBBR aspirated radiation shield to provide the same aspiration as the EBBR sensors received). Measurements of aspirator flow were also recorded. This information was provided to the mentor. The mentor then compared the field checks with the data recorded by the EBBRs. The periods of data and data fields that are incorrect because of the checks are listed below. Times are those at which the data are reported. Data Fields 5 minute: tair_top, tair_bot, thum_top, thum_bot, hum_top, hum_bot, vp_top, vp_bot 15 minute: rr_thum_r, rr_thum_l, mv_hum_r, mv_hum_l, tair_r, tair_l 30 minute: tair_top, tair_bot, thum_top, thum_bot, hum_top, hum_bot, vp_top, vp_bot, bowen, e, h 5 minute: 1520, 1525, 1530, 1535, 1540, 1545, 1550, 1555, 1600, 1605 15 minute: 1530, 1545, 1600, 1615 30 minute: 1530, 1600, 1630 (EDITOR'S NOTE: The following analysis refers to all EBBRs installed in Nov 1994) Results of the T/RH comparisons: The combined accuracy of the HMI31 and EBBR temperature sensors (thermocouples or PRTDs) is +/- 0.4 degrees C. The combined accuracy of the HMI31 and EBBR RH sensors is +/- 4% for RH less than 80%, and +/- 6% for RH greater than 80%. The combined accuracy for each pair of EBBR sensors of the same type is essentially the same as the quantities stated above. All of the pairs of EBBR sensors show differences that fall within the stated combined accuracies. Although this sounds wonderful, a few of the differences are close to the combined accuracy, which, because of the small differences in temperature being measured (normally smaller than the magnitude of the combined accuracy) could lead to some incorrect estimation of sensible and latent heat flux. However, unless there would be substantial differences of calibration slope of two sensors in a pair, the switching of height of the sensors every 15 minutes by the automatic exchange mechanism will remove the offset between the sensors. The comparisons between the EBBR sensors and the HMI31 T/RH meter showed much larger differences. The range of differences were: -2.4 to 0.0 degrees for the thermocouples, -2.1 to 0.1 degrees for the RH probe PRTDs, and -6.6 to 6.7 percent for the RH sensors. Six Thermocouples indicated differences from the HMI31 greater than the combined accuracy. Seven PRTDs indicated differences from the HMI31 greater than the combined accuracy. Four RH sensors indicated differences from the HMI31 greater than the combined accuracy. The temperature differences (for both thermocouples and PRTDs) were nearly all of one sign; the HMI31 indicated the greater temperature, which may suggest a bias in the HMI31 temperature measurement, even though a dozen differences of +/- 0.2 degrees were measured. Four differences of zero and only one positive difference (out of 40) were measured. Thirteen of the 20 RH differences were positive (HMI31 indicating the lower RH), with the differences near the level of the combined accuracies being approximately 50% positive and 50% negative. It does not appear that the HMI31 has a RH bias. Plots of EBBR sensor/HMI31 differences as a function of time from the installation of the individual sensors (a range of 10 to 30 months in the field) shows no obvious pattern of sensor drift with time. This is encouraging. |
Measurements: | sgp5ebbrE20.b1:
sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/13/1995 | 1300 | 10/13/1995 | 1600 |
Subject: | SGP/EBBR/E20 - 3-month Check |
DataStreams: | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
Description: | During EBBR 3 month checks the Automatic Exchange Mechanism is disabled (reflected by home signals near zero) so that the two aspirator units can be placed at the same height. The measurements during this period, at least, do not produce correct outputs of bowen ratio (bowen), sensible heat flux (h), or latent heat flux (e), nor do the air temperature and relative humidity measurements indicate gradients. Checks performed before or after the AEM is disabled also lead to some incorrect data. |
Measurements: | sgp5ebbrE20.b1:
sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
04/30/2002 | 2000 | 04/30/2002 | 2031 |
Subject: | SGP/EBBR/E18 - 6 Month Checks |
DataStreams: | sgp15ebbrE18.b1, sgp30ebbrE18.b1, sgp5ebbrE18.b1 |
Description: | The indicated measurements were incorrect during the 6 month checks. |
Measurements: | sgp15ebbrE18.b1:
sgp30ebbrE18.b1:
sgp5ebbrE18.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
05/01/2002 | 1910 | 05/01/2002 | 1946 |
Subject: | SGP/EBBR/E20 - 6 Month Checks |
DataStreams: | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
Description: | The indicated measurements were incorrect during the 6 month checks. |
Measurements: | sgp5ebbrE20.b1:
sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
11/01/2001 | 0000 | 03/29/2002 | 1631 |
Subject: | SGP/EBBR/E18 - Version 6 Produced Noisy Fluxes |
DataStreams: | sgp30ebbrE18.b1 |
Description: | Version 6 of the CR10 program produced noisy latent and sensible heat fluxes. That ended on March 29 after a recalibration unit was installed with version 8. |
Measurements: | sgp30ebbrE18.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
04/06/2002 | 0030 | 04/17/2002 | 1401 |
05/01/2002 | 0300 | 05/28/2002 | 2031 |
11/14/2001 | 1945 | 11/14/2001 | 2001 |
11/25/2001 | 0215 | 11/25/2001 | 1901 |
11/28/2001 | 1145 | 11/28/2001 | 1501 |
11/29/2001 | 0745 | 11/29/2001 | 0931 |
11/29/2001 | 1415 | 11/30/2001 | 0431 |
12/02/2001 | 0145 | 12/02/2001 | 0201 |
12/03/2001 | 0045 | 12/03/2001 | 0101 |
12/24/2001 | 2015 | 12/24/2001 | 2031 |
12/25/2001 | 1915 | 12/25/2001 | 2031 |
01/18/2002 | 0115 | 01/18/2002 | 0201 |
01/24/2002 | 2115 | 01/24/2002 | 2131 |
01/28/2002 | 1345 | 01/28/2002 | 1401 |
02/13/2002 | 2215 | 02/14/2002 | 0801 |
02/25/2002 | 2345 | 02/26/2002 | 0001 |
03/14/2002 | 1515 | 03/29/2002 | 1831 |
04/18/2002 | 2230 | 04/30/2002 | 2031 |
01/22/2002 | 1615 | 01/22/2002 | 1631 |
Subject: | SGP/EBBR/E18 - AEM Hung |
DataStreams: | sgp15ebbrE18.b1, sgp30ebbrE18.b1, sgp5ebbrE18.b1 |
Description: | The automatic exchange mechanism did not work properly for a number of time periods. The Bowen ratio, latent heat flux, and sensible heat flux were incorrect also during this condition. |
Measurements: | sgp15ebbrE18.b1:
sgp30ebbrE18.b1:
sgp5ebbrE18.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
03/29/2002 | 1815 | 03/29/2002 | 2131 |
Subject: | SGP/EBBR/E18 - Soil Heat Flows Incorrect After Calibration Changeout |
DataStreams: | sgp30ebbrE18.b1 |
Description: | The soil heat flows were incorrect while the EBBR changeout was being done. |
Measurements: | sgp30ebbrE18.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
05/20/2002 | 0600 | 05/20/2002 | 2001 |
05/21/2002 | 0430 | 05/21/2002 | 1731 |
05/22/2002 | 1130 | 05/22/2002 | 1631 |
Subject: | SGP/EBBR/E18 - Reprocess: Soil Heat Flow #1 Incorrect |
DataStreams: | sgp30ebbrE18.b1 |
Description: | Soil Heat Flow 1 was incorrect during the indicated periods. Average soil heat flow, sensible heat flux, and latent heat flux were affected; these can be recalculated using the remaining good sets of soil sensors as follows: ave_shf = (g2 + g3 + g4 + g5)/4 e = -(q + ave_shf)/(1 + bowen) h = -(q + e + ave_shf) |
Measurements: | sgp30ebbrE18.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
04/09/2002 | 1900 | 05/14/2002 | 1846 |
Subject: | SGP/EBBR/E18 - Left Air Temperature Incorrect |
DataStreams: | sgp15ebbrE18.b1, sgp30ebbrE18.b1, sgp5ebbrE18.b1 |
Description: | The left air temperature was incorrect much of the time, causing the Bowen ratio, sensible heat flux, and latent heat flux to be incorrect also. |
Measurements: | sgp15ebbrE18.b1:
sgp30ebbrE18.b1:
sgp5ebbrE18.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
04/17/2002 | 1430 | 04/17/2002 | 1431 |
Subject: | SGP/EBBR/E18 - Reference Temperature Incorrect |
DataStreams: | sgp15ebbrE18.b1, sgp30ebbrE18.b1, sgp5ebbrE18.b1 |
Description: | The reference temperature was incorrect during the checks of the left air temperature sensor, leading to all gradient measurements, Bowen ratio, sensible heat flux, latent heat flux, soil temperature, and soil moisture measurements being incorrect. |
Measurements: | sgp15ebbrE18.b1:
sgp30ebbrE18.b1:
sgp5ebbrE18.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
11/28/2001 | 2045 | 01/23/2002 | 1801 |
Subject: | SGP/EBBR/E20 - AEM Hung |
DataStreams: | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
Description: | The automatic exchange mechanism frequently hung in one position. The home signals and automated qc in the netcdf data files indicate when this occurred. Bowen ratio, sensible heat flux, and latent heat flux are incorrect for this condition. |
Measurements: | sgp5ebbrE20.b1:
sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
11/28/2001 | 0045 | 11/28/2001 | 2031 |
02/06/2002 | 2130 | 02/07/2002 | 0331 |
Subject: | SGP/EBBR/E20 - Battery Voltage Low |
DataStreams: | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.00, sgp5ebbrE20.b1 |
Description: | When the battery voltage is below 10.5 volts, most of the measurements are suspect. |
Measurements: | sgp5ebbrE20.b1:
sgp5ebbrE20.00:
sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
11/14/2001 | 1605 | 11/28/2001 | 2031 |
Subject: | SGP/EBBR/E20 - Pressure Almost Constant |
DataStreams: | sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
Description: | During the indicated period the pressure went to an almost constant 102 to 105 kPa. This occurred after the replacement of another sensor. The incorrect pressure values affect the sensible and latent heat flux calculations. |
Measurements: | sgp5ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
12/12/2001 | 1915 | 12/12/2001 | 2031 |
Subject: | SGP/EBBR/E20 - Reprocess: Soil Heat Flow #3 Incorrect During Sensor Changeout |
DataStreams: | sgp30ebbrE20.b1 |
Description: | Soil heat flow #3 measurements were incorrect during it's replacement. Average soil heat flow, sensible heat flux, and latent heat flux were affected; these can be recalculated using the remaining good sets of soil sensors as follows: ave_shf = (g1 + g5)/2 e = -(q + ave_shf)/(1 + bowen) h = -(q + e + ave_shf) Note: during the time period referenced here, soil heat flow #4 and #2 were also incorrect. This quality information is documented in D020717.46, D020717.47 and D020726.1. |
Measurements: | sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
01/12/2002 | 0315 | 01/13/2002 | 2131 |
01/17/2002 | 0915 | 01/21/2002 | 0901 |
02/20/2002 | 1645 | 02/20/2002 | 1831 |
12/04/2001 | 0000 | 12/12/2001 | 1914 |
02/09/2002 | 0115 | 02/12/2002 | 0731 |
Subject: | SGP/EBBR/E20 - Reprocess: Soil Heat Flow #2 Has a Negative Offset |
DataStreams: | sgp30ebbrE20.b1 |
Description: | Soil heat flow #2 measurements had a negative offset. Negative values were too small and negative values occurred when positive values should have. This can occur when there is a poor wire connection or a J-panel over-voltage protection device has failed. Average soil heat flow, sensible heat flux, and latent heat flux were affected; these can be recalculated using the remaining good sets of soil sensors as follows: ave_shf = (g1 + g3 + g4 + g5)/4 e = -(q + ave_shf)/(1 + bowen) h = -(q + e + ave_shf) |
Measurements: | sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
12/24/2001 | 0532 | 12/27/2001 | 1901 |
Subject: | SGP/EBBR/E20 - Reprocess: Soil Heat Flow #4 Incorrect |
DataStreams: | sgp30ebbrE20.b1 |
Description: | Soil heat flow #4 was incorrect because it's wires were loose from the connection terminals. Average soil heat flow, sensible heat flux, and latent heat flux were affected; these can be recalculated using the remaining good sets of soil sensors as follows: ave_shf = (g1 + g2 + g3 + g5)/4 e = -(q + ave_shf)/(1 + bowen) h = -(q + e + ave_shf) |
Measurements: | sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
05/15/2002 | 1700 | 05/15/2002 | 1701 |
11/14/2001 | 1600 | 11/14/2001 | 1601 |
05/29/2002 | 1830 | 05/29/2002 | 1901 |
11/27/2001 | 1800 | 11/27/2001 | 1801 |
Subject: | SGP/EBBR/E20 - Measurements Zero |
DataStreams: | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.00, sgp5ebbrE20.b1 |
Description: | Most measurements were zero during the indicated periods. This often happens for the first reported data time after a CR10 datalogger restart. |
Measurements: | sgp5ebbrE20.b1:
sgp5ebbrE20.00:
sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
02/22/2002 | 2015 | 02/22/2002 | 2101 |
02/23/2002 | 1745 | 02/23/2002 | 1801 |
02/24/2002 | 0045 | 02/25/2002 | 0201 |
03/05/2002 | 2015 | 03/06/2002 | 0201 |
03/06/2002 | 1915 | 03/07/2002 | 1901 |
Subject: | SGP/EBBR/E20 - Reprocess: Soil Temperature #3 Incorrect |
DataStreams: | sgp30ebbrE20.b1 |
Description: | Soil temperature 3 was incorrect during the indicated periods. Average soil heat flow, sensible heat flux, and latent heat flux were affected; these can be recalculated using the remaining good sets of soil sensors as follows: ave_shf = (g1 + g2 + g4 + g5)/4 e = -(q + ave_shf)/(1 + bowen) h = -(q + e + ave_shf) |
Measurements: | sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
02/20/2002 | 1745 | 02/20/2002 | 1901 |
Subject: | SGP/EBBR/E20 - Measurements Incorrect During Sensor Changeout |
DataStreams: | sgp30ebbrE20.b1 |
Description: | The replacement of soil heat flow 2 caused the loss of initial soil temperature values used in the calculation of CES, G, C, ave_shf, bowen, e, and h. |
Measurements: | sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
12/27/2001 | 1845 | 12/27/2001 | 1901 |
05/15/2002 | 1715 | 05/15/2002 | 1731 |
Subject: | SGP/EBBR/E20 - Measurements Incorrect |
DataStreams: | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.00, sgp5ebbrE20.b1 |
Description: | Many measurements were incorrect because of the lack of an initial 15 minute value to use for gradient or soil change of energy storage calculations. |
Measurements: | sgp5ebbrE20.b1:
sgp5ebbrE20.00:
sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
12/12/2001 | 2032 | 12/24/2001 | 0531 |
Subject: | SGP/EBBR/E20 - Reprocess: Soil Heat Flow #2 and #4 incorrect |
DataStreams: | sgp30ebbrE20.b1 |
Description: | Soil heat flow #2 measurements had a negative offset. Negative values were too small and negative values occurred when positive values should have. This can occur when there is a poor wire connection or a J-panel over-voltage protection device has failed. Soil heat flow #4 was incorrect because it's wires were loose from the connection terminals. Average soil heat flow, sensible heat flux, and latent heat flux were affected; these can be recalculated using the remaining good sets of soil sensors as follows: ave_shf = (g1 + g3 + g5)/3 e = -(q + ave_shf)/(1 + bowen) h = -(q + e + ave_shf) |
Measurements: | sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
04/01/2001 | 0000 | 06/18/2003 | 2359 |
Subject: | SGP/EBBR - Incorrect Units for Soil Heat Capacity (cs1, cs2, cs3, cs4, cs5) in 30EBBR |
DataStreams: | sgp30ebbrE12.b1, sgp30ebbrE13.b1, sgp30ebbrE15.b1, sgp30ebbrE18.b1, sgp30ebbrE19.b1, sgp30ebbrE2.b1, sgp30ebbrE20.b1, sgp30ebbrE22.b1, sgp30ebbrE26.b1, sgp30ebbrE4.b1, sgp30ebbrE7.b1, sgp30ebbrE8.b1, sgp30ebbrE9.b1 |
Description: | The units for Soil Heat Capacity (cs1, cs2, cs3, cs4, cs5) in the EBBR 30 minute netcdf header have been incorrect from the beginning of processing the data into netcdf files. The correct units are MJ/m^3/C. This does not affect the data quality. |
Measurements: | sgp30ebbrE2.b1:
sgp30ebbrE26.b1:
sgp30ebbrE9.b1:
sgp30ebbrE22.b1:
sgp30ebbrE13.b1:
sgp30ebbrE7.b1:
sgp30ebbrE18.b1:
sgp30ebbrE12.b1:
sgp30ebbrE4.b1:
sgp30ebbrE15.b1:
sgp30ebbrE19.b1:
sgp30ebbrE20.b1:
sgp30ebbrE8.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
12/01/1993 | 1200 | 06/18/2003 | 1159 |
Subject: | SGP/EBBR - Incorrect Units for Soil Heat Capacity (cs1, cs2, cs3, cs4, cs5) in 30EBBR |
DataStreams: | sgp30ebbrE12.b1, sgp30ebbrE13.b1, sgp30ebbrE15.b1, sgp30ebbrE20.b1, sgp30ebbrE22.b1, sgp30ebbrE26.b1, sgp30ebbrE4.b1, sgp30ebbrE7.b1, sgp30ebbrE8.b1, sgp30ebbrE9.b1 |
Description: | The units for Soil Heat Capacity (cs1, cs2, cs3, cs4, cs5) in the EBBR 30 minute netcdf header have been incorrect from the beginning of processing the data into netcdf files. The correct units are MJ/m^3/C. This does not affect the data quality. (NOTE: The actual begin date of some of these data streams is as early as 7/4/93. This DQR applies to all 30m EBBR data.) |
Measurements: | sgp30ebbrE26.b1:
sgp30ebbrE9.b1:
sgp30ebbrE7.b1:
sgp30ebbrE4.b1:
sgp30ebbrE12.b1:
sgp30ebbrE15.b1:
sgp30ebbrE22.b1:
sgp30ebbrE13.b1:
sgp30ebbrE8.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
11/25/2002 | 2215 | 11/25/2002 | 2245 |
Subject: | SGP/EBBR/E18 - Data Incorrect during 6 month checks |
DataStreams: | sgp15ebbrE18.b1, sgp30ebbrE18.b1, sgp5ebbrE18.b1 |
Description: | Some of the measurements are incorrect during the 6 month checks. |
Measurements: | sgp15ebbrE18.b1:
sgp30ebbrE18.b1:
sgp5ebbrE18.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
11/26/2002 | 1900 | 11/26/2002 | 1930 |
Subject: | SGP/EBBR/E20 - Data Incorrect during 6 month checks |
DataStreams: | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
Description: | Some of the measurements are incorrect during the 6 month checks. |
Measurements: | sgp5ebbrE20.b1:
sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
09/01/2002 | 2100 | 11/12/2002 | 2130 |
07/08/2002 | 1800 | 07/19/2002 | 1430 |
08/20/2002 | 2100 | 08/26/2002 | 0300 |
Subject: | SGP/EBBR/E18 - Reprocess: Soil Heat Flow #1 High |
DataStreams: | sgp30ebbrE18.b1 |
Description: | Soil Heat Flow #1 measurements were 2X to offscale high during these periods. See below for a work-around. |
Measurements: | sgp30ebbrE18.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
07/20/2002 | 2000 | 07/26/2002 | 2030 |
07/27/2002 | 0300 | 07/30/2002 | 2000 |
08/03/2002 | 0130 | 08/06/2002 | 2030 |
08/07/2002 | 0200 | 08/09/2002 | 1900 |
08/12/2002 | 0130 | 08/17/2002 | 2030 |
08/17/2002 | 2130 | 08/19/2002 | 1830 |
Subject: | SGP/EBBR/E18 - Reprocess: Soil Heat Flow #4 High |
DataStreams: | sgp30ebbrE18.b1 |
Description: | Soil Heat Flow #4 measurements were 2X or offscale high during this period when compared with the other soil heat flow measurements. See below for a work-around. |
Measurements: | sgp30ebbrE18.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
11/12/2002 | 2200 | 11/12/2002 | 2229 |
Subject: | SGP/EBBR/E18 - Data Mostly Zero Following Logger Restart |
DataStreams: | sgp15ebbrE18.b1, sgp30ebbrE18.b1, sgp5ebbrE18.b1 |
Description: | Most of the measurements were zero, which normally happens after a datalogger restart. The restart on 11/12/02 occurred after replacement of soil heat flow #1. |
Measurements: | sgp15ebbrE18.b1:
sgp30ebbrE18.b1:
sgp5ebbrE18.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
11/12/2002 | 2230 | 11/12/2002 | 2259 |
Subject: | SGP/EBBR/E18 - Data Incorrect After Logger Restart |
DataStreams: | sgp30ebbrE18.b1 |
Description: | Because soil temperature measurements were not available from the beginning of the half hour, the change in soil energy storage could not be calculated and thus is incorrect. There is no fix to this problem. Average Soil Heat Flow, Sensible Heat Flux (h), and Latent Heat Flux (e) can not be calculated using the available, remaining measurements. |
Measurements: | sgp30ebbrE18.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/09/2002 | 1400 | 10/15/2002 | 2030 |
Subject: | SGP/EBBR/E18 - Water in Net Radiometer Dome |
DataStreams: | sgp30ebbrE18.b1 |
Description: | The net radiation measurement is incorrect. Measurements calculated using net radiation are also incorrect. No work-around is possible for this situation. |
Measurements: | sgp30ebbrE18.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
11/13/2002 | 1830 | 11/13/2002 | 1859 |
12/11/2002 | 1900 | 12/11/2002 | 1929 |
Subject: | SGP/EBBR/E20 - Data Zero following logger restarts |
DataStreams: | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
Description: | Most of the measurements were zero, which normally happens after a datalogger restart. |
Measurements: | sgp5ebbrE20.b1:
sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
08/09/2002 | 1705 | 09/18/2002 | 1700 |
Subject: | SGP/EBBR/E20 - REPROCESS: Soil Temperature #2 Incorrect |
DataStreams: | sgp30ebbrE20.b1 |
Description: | Soil Temperature #2 was incorrect, apparently from am loose wire after replacement of the EBBR unit. The indicated measurements that are calculated using soil temperature are also incorrect. See the work-around below. |
Measurements: | sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
11/13/2002 | 1900 | 11/13/2002 | 1929 |
12/11/2002 | 2000 | 12/11/2002 | 2029 |
Subject: | SGP/EBBR/E20 - Change of Energy Storage Incorrect |
DataStreams: | sgp30ebbrE20.b1 |
Description: | Because soil temperature measurements were not available from the beginning of the half hour, the change in soil energy storage could not be calculated and thus is incorrect. There is no fix to this problem. Average Soil Heat Flow, Sensible Heat Flux (h), and Latent Heat Flux (e) can not be calculated using the available, remaining measurements. |
Measurements: | sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/23/2002 | 0215 | 10/30/2002 | 2000 |
Subject: | SGP/EBBR/E20 - Battery voltage low |
DataStreams: | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
Description: | When Battery Voltage drops below 10.5 volts, most measurements are suspect and some are often incorrect. The user will need to inspect the data carefully to determine the useability of the data. |
Measurements: | sgp5ebbrE20.b1:
sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
12/04/2002 | 1200 | 12/05/2002 | 1630 |
Subject: | SGP/EBBR/E20 - Wind speed and direction frozen |
DataStreams: | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE2.b1 |
Description: | Wind Speed and Dierction were frozen in place by an ice storm. |
Measurements: | sgp15ebbrE20.b1:
sgp5ebbrE2.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
08/07/2002 | 1630 | 08/07/2002 | 1730 |
Subject: | SGP/EBBR/E20 - AEM Hung between Home Positions |
DataStreams: | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
Description: | When the AEM (Automatic Exchange Mechanism) is hung inbetween home positions, the gradients of temperature and relative humidity, and thus sensible and latent heat fluxes, are incorrect. There is no work-around to this problem. |
Measurements: | sgp5ebbrE20.b1:
sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
12/30/2002 | 2030 | 01/08/2003 | 1730 |
Subject: | SGP/EBBR/E20 - REPROCESS: Heat Flow #3 and #5 Incorrect |
DataStreams: | sgp30ebbrE20.b1 |
Description: | Soil Heat Flow #3 was incorrect because part of the lead wire was cut; apparent vandalism. Soil Heat Flow #5 had been incorrect because of other causes, but was replaced at the same time as #3. |
Measurements: | sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
08/09/2002 | 1705 | 08/09/2002 | 1730 |
Subject: | SGP/EBBR/E20 - Data incorrect during instrument maintenance |
DataStreams: | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
Description: | Most of the data was incorrect just after the EBBR unit was replaced. |
Measurements: | sgp5ebbrE20.b1:
sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
12/03/2002 | 1200 | 12/04/2002 | 0400 |
12/06/2002 | 2000 | 12/07/2002 | 0230 |
12/08/2002 | 0230 | 12/09/2002 | 0500 |
12/09/2002 | 0930 | 12/20/2002 | 1830 |
12/20/2002 | 2100 | 12/21/2002 | 1630 |
12/21/2002 | 1730 | 12/22/2002 | 0100 |
12/22/2002 | 0130 | 12/30/2002 | 2000 |
Subject: | SGP/EBBR/E20 - REPROCESS: Soil Heat Flow #5 Incorrect |
DataStreams: | sgp30ebbrE20.b1 |
Description: | Soil Heat Flow #5 was incorrect during these periods. See below for a work-around. |
Measurements: | sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
11/19/2002 | 1700 | 11/19/2002 | 2200 |
11/18/2002 | 1900 | 11/18/2002 | 2200 |
11/20/2002 | 1430 | 11/20/2002 | 2200 |
11/21/2002 | 2000 | 11/21/2002 | 2030 |
11/22/2002 | 1630 | 11/22/2002 | 2000 |
11/23/2002 | 1430 | 11/23/2002 | 2230 |
11/24/2002 | 1700 | 11/24/2002 | 2200 |
11/27/2002 | 2030 | 11/27/2002 | 2300 |
11/28/2002 | 1700 | 11/28/2002 | 2300 |
11/29/2002 | 1330 | 11/29/2002 | 2130 |
12/01/2002 | 1930 | 12/01/2002 | 2030 |
12/02/2002 | 1430 | 12/02/2002 | 2230 |
Subject: | SGP/EBBR/E20 - REPROCESS: Soil Temperature #1 Incorrect |
DataStreams: | sgp30ebbrE20.b1 |
Description: | Soil Temperature #1 was intermittently incorrect. The cause is unknown. The indicated measurements that are calculated using soil temperature are also incorrect. |
Measurements: | sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
07/19/2002 | 1430 | 07/20/2002 | 2000 |
07/26/2002 | 2030 | 07/27/2002 | 0300 |
07/30/2002 | 2000 | 08/03/2002 | 0130 |
08/06/2002 | 2030 | 08/07/2002 | 0200 |
08/09/2002 | 1900 | 08/12/2002 | 0130 |
08/17/2002 | 2030 | 08/17/2002 | 2130 |
08/19/2002 | 1830 | 08/20/2002 | 2100 |
Subject: | SGP/EBBR/E18 - REPROCESS: Soil Heat Flow #1 and #4 High |
DataStreams: | sgp30ebbrE18.b1 |
Description: | Soil Heat Flow #1 and #4 measurements were 2X to offscale high during these periods. See suggestions for a work-around. |
Measurements: | sgp30ebbrE18.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
12/30/2002 | 2030 | 01/08/2003 | 1730 |
Subject: | SGP/EBBR/E20 - REPROCESS: Soil Temperature #3 Incorrect |
DataStreams: | sgp30ebbrE20.b1 |
Description: | Soil Temperature #3 was incorrect. The cause is apparently vandalism; the probe leads were cut. The indicated measurements that are calculated using soil temperature are also incorrect. DQR D030117.19 already provides the work-around for calculating correct sensible (h) and latent heat (e) fluxes, as soil heat flow #3 and soil heat flow #5 were also incorrect during this period. That work-around is repeated below. |
Measurements: | sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/20/2002 | 1300 | 10/20/2002 | 1500 |
Subject: | SGP/EBBR/E20 - Resistance-based Measurements Incorrect |
DataStreams: | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
Description: | When the Reference Temperature in the EBBR enclosure is not reported correctly, it affects all resistance-based measurements that are adjusted with the temperature of the reference junction. No work-around is possible for this situation. |
Measurements: | sgp5ebbrE20.b1:
sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
08/09/2002 | 1730 | 12/11/2002 | 1930 |
Subject: | SGP/EBBR/E20 - REPROCESS: Net Rad Coefficients Incorrect |
DataStreams: | sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
Description: | The Net Radiometer coefficients were incorrect in the CR10 program when the replacement EBBR unit was installed on 08/09/02. The data can be easily corrected; see the Suggestion area below. |
Measurements: | sgp5ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
12/20/2002 | 1830 | 12/20/2002 | 2100 |
12/21/2002 | 1630 | 12/21/2002 | 1730 |
12/22/2002 | 0100 | 12/22/2002 | 0130 |
Subject: | SGP/EBBR/E20 - REPROCESS: Soil Temperature #1 and Soil Heat Flow #5 Incorrect |
DataStreams: | sgp30ebbrE20.b1 |
Description: | Soil Temperature #1 and Soil Heat Flow #5 were incorrect during these periods. The indicated calculated measurements are also incorrect. |
Measurements: | sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
02/01/2003 | 1000 | 02/01/2003 | 1000 |
Subject: | SGP/EBBR/E20 - RHtop Zero |
DataStreams: | sgp30ebbrE20.b1 |
Description: | The RHtop value in the 30 minute file is zero. 5 and 15 minute files show RHtop correctly. This behavior has been seen infrequently and can probably be attributed to a CR10 communication error. No other data, including the fluxes, are affected. |
Measurements: | sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
04/01/2003 | 2145 | 04/01/2003 | 2200 |
Subject: | SGP/EBBR/E18 - AEM Hung |
DataStreams: | sgp15ebbrE18.b1, sgp30ebbrE18.b1, sgp5ebbrE18.b1 |
Description: | The AEM was hung inbetween home positions, causing many measurements to be incorrect. |
Measurements: | sgp15ebbrE18.b1:
sgp30ebbrE18.b1:
sgp5ebbrE18.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
01/01/2003 | 0000 | 01/08/2003 | 1730 |
Subject: | SGP/EBBR/E20 - Soil Heat Flow#5 Incorrect |
DataStreams: | sgp15ebbrE20.b1, sgp30ebbrE20.b1 |
Description: | Soil Heat Flow #5 was producing incorrect values. Average soil heat flow, sensible heat flux, and latent heat flux were affected. |
Measurements: | sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
01/08/2003 | 2100 | 01/08/2003 | 2100 |
Subject: | SGP/EBBR/E20 - Soil Storage Incorrect After Startup |
DataStreams: | sgp30ebbrE20.b1 |
Description: | For the half hour data after CR10 datalogger startup, stored soil temperature values do not exist from the beginning of the half hour. Therefore soil heat storage can not be calculated correctly. This affects numerous measurements that are calculated using soil heat storage. |
Measurements: | sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
04/15/2003 | 2120 | 04/15/2003 | 2215 |
Subject: | SGP/EBBR/E18 - 6 Month Checks |
DataStreams: | sgp15ebbrE18.b1, sgp30ebbrE18.b1, sgp5ebbrE18.b1 |
Description: | Many measurements were incorrect while the AEM was positioned with both aspirators at the same height for comparison checks. |
Measurements: | sgp15ebbrE18.b1:
sgp30ebbrE18.b1:
sgp5ebbrE18.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
04/16/2003 | 1950 | 04/16/2003 | 2045 |
Subject: | SGP/EBBR/E20 - 6 Month Checks |
DataStreams: | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
Description: | Many measurements were incorrect while the AEM was positioned with both aspirators at the same height for comparison checks. |
Measurements: | sgp5ebbrE20.b1:
sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
08/30/2003 | 1500 | 09/02/2003 | 2100 |
Subject: | SGP/EBBR/E18 - Water in Net Radiometer; Surface Fluxes are Incorrect |
DataStreams: | sgp30ebbrE18.b1, sgp5ebbrE18.b1, sgp15ebbrE18.b1 |
Description: | The net radiometer top dome was punctured by migrating birds. This alone does not cause incorrect net radiation measurements. However, when it subsequently rains, water collects in the bottom dome, causing the net radiation measurements to be too large during the day and too small at night. |
Measurements: | sgp15ebbrE18.b1:
sgp30ebbrE18.b1:
sgp5ebbrE18.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/15/2003 | 2100 | 10/29/2003 | 2300 |
Subject: | SGP/EBBR/E20 - Fuse Blown in AEM |
DataStreams: | sgp30ebbrE20.b1, sgp15ebbrE20.b1, sgp5ebbrE20.b1 |
Description: | When the EBBR system restarted on 15 Oct. 2003, the AEM malfunctioned. Surface fluxes data during this period are incorrect. |
Measurements: | sgp5ebbrE20.b1:
sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
09/27/2003 | 1800 | 12/10/2003 | 2230 |
Subject: | SGP/EBBR/E20 - Reprocess: Soil Temperature Probe #1 Measurements Spiked |
DataStreams: | sgp15ebbrE20.b1, sgp30ebbrE20.b1 |
Description: | The soil temperature #1 measurement spiked quite high at times. This affected a number of measurements that are dependent on the soil temperature measurements. |
Measurements: | sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
09/30/2003 | 0000 | 10/01/2003 | 2100 |
Subject: | SGP/EBBR/E20 - Water in Net Radiometer, Surface Fluxes Incorrect |
DataStreams: | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
Description: | The net radiometer top dome was punctured by migrating birds. This alone does not cause incorrect net radiation measurements. However, when it subsequently rains, water collects in the bottom dome, causing the net radiation measurements to be too large during the day and too small at night. |
Measurements: | sgp5ebbrE20.b1:
sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/28/2003 | 2225 | 10/28/2003 | 2315 |
Subject: | SGP/EBBR/E18 - 6 Month Checks |
DataStreams: | sgp15ebbrE18.b1, sgp30ebbrE18.b1, sgp5ebbrE18.b1 |
Description: | Many measurements were incorrect while the AEM was positioned with both aspirators at the same height for comparison checks. |
Measurements: | sgp15ebbrE18.b1:
sgp30ebbrE18.b1:
sgp5ebbrE18.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/29/2003 | 2200 | 10/29/2003 | 2245 |
Subject: | SGP/EBBR/E20 - 6 Month Checks |
DataStreams: | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
Description: | Many measurements were incorrect while the AEM was positioned with both aspirators at the same height for comparison checks. |
Measurements: | sgp5ebbrE20.b1:
sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
12/03/2003 | 0530 | 12/23/2003 | 2140 |
Subject: | SGP/EBBR/E20 - Wind Direction Incorrect |
DataStreams: | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
Description: | Wind direction is incorrect, reading at or about 0 or 15 to 25 degrees. |
Measurements: | sgp5ebbrE20.b1:
sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
11/28/2003 | 1430 | 01/21/2004 | 2130 |
Subject: | SGP/EBBR/E20 - Pressure Sensor Data Incorrect |
DataStreams: | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
Description: | The E20 pressure sensor suffered from spikes in pressure, which were related to increases in voltage during the day as the solar panels charged the battery. These spikes were not of a magnitude that would affect the 30 minute surface fluxes. Replacement of the pressure sensor solved the problem. |
Measurements: | sgp5ebbrE20.b1:
sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
12/13/2003 | 1100 | 12/13/2003 | 1230 |
Subject: | SGP/EBBR/E20 - Wind Speed Sensor Frozen By Ice Storm |
DataStreams: | sgp30ebbrE20.b1, sgp5ebbrE20.b1, sgp15ebbrE20.b1 |
Description: | The wind speed sensor was frozen stopped by ice from a storm. The wind speed and residual wind speed measurements are incorrect. |
Measurements: | sgp5ebbrE20.b1:
sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
01/26/2004 | 1915 | 04/13/2004 | 2045 |
Subject: | SGP/EBBR/E18 - AEM Sitting At Home 15 Position |
DataStreams: | sgp30baebbrE18.c1, sgp30ebbrE18.b1, sgp5ebbrE18.b1, sgp15ebbrE18.b1 |
Description: | After replacement of the AEM on 1/26/04, it exchanged briefly, then sat at the home 15 position until another replacement was available. |
Measurements: | sgp15ebbrE18.b1:
sgp30baebbrE18.c1:
sgp30ebbrE18.b1:
sgp5ebbrE18.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
01/28/2004 | 0140 | 01/28/2004 | 0305 |
02/05/2004 | 0145 | 02/05/2004 | 0520 |
Subject: | SGP/EBBR/E18 - Wind Speed Frozen Stopped By Ice |
DataStreams: | sgp15ebbrE18.b1, sgp30ebbrE18.b1, sgp5ebbrE18.b1 |
Description: | An ice storm froze the wind speed sensor to a stopped condition. The wind speed and residual wind speed measurements are incorrect. This sensor failure does not affect the sensible and latent heat fluxes. |
Measurements: | sgp15ebbrE18.b1:
sgp30ebbrE18.b1:
sgp5ebbrE18.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
01/28/2004 | 0140 | 01/28/2004 | 0305 |
Subject: | SGP/EBBR/E18 - Wind Direction Frozen Stopped By Ice |
DataStreams: | sgp30ebbrE18.b1, sgp5ebbrE18.b1 |
Description: | The wind direction sensor was frozen stopped by ice from a storm. The wind direction, sigma_wd, and residual wind speed measurements are incorrect. |
Measurements: | sgp30ebbrE18.b1:
sgp5ebbrE18.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
02/02/2004 | 0505 | 02/02/2004 | 1845 |
Subject: | SGP/EBBR/E20 - Wind Speed Frozen Stopped By Ice |
DataStreams: | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
Description: | An ice storm froze the wind speed sensor to a stopped condition. The wind speed and residual wind speed measurements are incorrect. This sensor failure does not affect the sensible and latent heat fluxes. |
Measurements: | sgp5ebbrE20.b1:
sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
02/02/2004 | 0535 | 02/02/2004 | 1755 |
Subject: | SGP/EBBR/E20 - Wind Direction Frozen Stopped By Ice |
DataStreams: | sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
Description: | The wind direction sensor was frozen stopped by ice from a storm. The wind direction, sigma_wd, and residual wind speed measurements are incorrect. |
Measurements: | sgp5ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
04/19/2004 | 0500 | 06/13/2004 | 1700 |
Subject: | SGP/EBBR/E18 - Pressure Low |
DataStreams: | sgp30ebbrE18.b1, sgp5ebbrE18.b1 |
Description: | Pressure readings suddenly dropped to unrealistic levels. Sensible Heat Flux was underestimated and Latent Heat Flux was overestimated because of this problem. |
Measurements: | sgp30ebbrE18.b1:
sgp5ebbrE18.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
03/01/2004 | 0000 | 03/31/2004 | 2355 |
Subject: | SGP/EBBR/E20 - Left Air Temperature Incorrect |
DataStreams: | sgp15ebbrE20.b1, sgp30baebbrE20.c1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
Description: | The left air temperature, and therefore top and bottom air temperatures were offscale or incorrect on occasion. Bowen ratio, sensible heat flux, and latent heat flux were also incorrect during those times. Inspection of the data is required to detect the incorrect periods. |
Measurements: | sgp5ebbrE20.b1:
sgp15ebbrE20.b1:
sgp30baebbrE20.c1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
07/09/2004 | 1745 | 08/04/2004 | 1915 |
Subject: | SGP/EBBR/E20 - Wind Direction Stuck at 100 Degrees |
DataStreams: | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
Description: | The wind direction sensor was stuck at about 100 degrees. This did not affect the primary measurements (net radiation, soil heat flow, sensible heat flux, latent heat flux). |
Measurements: | sgp5ebbrE20.b1:
sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
06/28/2004 | 1300 | 07/28/2004 | 1500 |
Subject: | SGP/EBBR/E18 - Soil Temperature and Moisture Probes in Set #1 Spiked Outputs |
DataStreams: | sgp30ebbrE18.b1 |
Description: | Soil moisture #1 and soil temperature #1 occasionally spiked at the same time. Little sensible and latent heat flux data were affected. |
Measurements: | sgp30ebbrE18.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
08/03/2004 | 0300 | 09/15/2004 | 2000 |
09/24/2004 | 0700 | 09/29/2004 | 1800 |
Subject: | SGP/EBBR/E20 - AEM Failure |
DataStreams: | sgp5ebbrE20.b1, sgp15ebbrE20.b1, sgp30ebbrE20.b1 |
Description: | The AEM hung inbetween positions; home signals were zero. The AEM fuse kept blowing, most likely because of worn rails or sleeves. This condition may reoccur. |
Measurements: | sgp5ebbrE20.b1:
sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
07/06/2004 | 1830 | 07/06/2004 | 2100 |
Subject: | SGP/EBBR/E18 - Soil Temperature #2 Incorrect |
DataStreams: | sgp30ebbrE18.b1 |
Description: | Soil Temperature #2 was incorrect during the indicated period. Average soil heat flow, sensible heat flux, and latent heat flux are incorrect, as a result. |
Measurements: | sgp30ebbrE18.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
09/08/2004 | 2130 | 09/15/2004 | 1930 |
Subject: | SGP/EBBR/E20 - Soil Heat Flow #3 and Soil Temperature #3 Incorrect |
DataStreams: | sgp15ebbrE20.b1, sgp30ebbrE20.b1 |
Description: | |
Measurements: | sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
09/15/2004 | 1930 | 09/15/2004 | 2030 |
Subject: | SGP/EBBR/E20 - All Soil Measurements Incorrect |
DataStreams: | sgp15ebbrE20.b1, sgp30ebbrE20.b1 |
Description: | All soil measurements were incorrect during the replacement of soil heat flow #3 and soil temperature #3. |
Measurements: | sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
09/28/2004 | 2230 | 09/28/2004 | 2300 |
Subject: | SGP/EBBR/E18 - 6 Month Checks |
DataStreams: | sgp15ebbrE18.b1, sgp30ebbrE18.b1, sgp5ebbrE18.b1 |
Description: | Many measurements were incorrect while the AEM was positioned with both aspirators at the same height for comparison checks. |
Measurements: | sgp15ebbrE18.b1:
sgp30ebbrE18.b1:
sgp5ebbrE18.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
09/29/2004 | 1730 | 09/29/2004 | 1800 |
Subject: | SGP/EBBR/E20 - 6 Month Checks |
DataStreams: | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
Description: | Many measurements were incorrect while the AEM was positioned with both aspirators at the same height for comparison checks. |
Measurements: | sgp5ebbrE20.b1:
sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
11/02/2004 | 1330 | 03/02/2005 | 1930 |
Subject: | SGP/EBBR/E20 - Soil Moisture #4 and Soil Temperature #4 Incorrect |
DataStreams: | sgp15ebbrE20.b1, sgp30ebbrE20.b1 |
Description: | Failures of a multiplexer channel and a J-panel channel caused soil temperature #4 and soil moisture #4 to spike and drift at times. Replacement of the failed equipment solved the problem. |
Measurements: | sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
11/26/2004 | 2100 | 12/08/2004 | 2100 |
Subject: | SGP/EBBR/E20 - Soil Heat Flow #4 Incorrect |
DataStreams: | sgp15ebbrE20.b1, sgp30ebbrE20.b1 |
Description: | Soil Heat Flow #4 was missing or offscale and therefore incorrect during the stated period. |
Measurements: | sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
01/05/2005 | 1810 | 01/06/2005 | 2045 |
Subject: | SGP/EBBR/E18 - Wind Speed Frozen Stopped By Ice Storm |
DataStreams: | sgp15ebbrE18.b1, sgp30ebbrE18.b1, sgp5ebbrE18.b1 |
Description: | An ice storm froze the wind speed sensor to a stopped condition. The wind speed and residual wind speed measurements are incorrect. This sensor failure does not affect the sensible and latent heat fluxes. |
Measurements: | sgp15ebbrE18.b1:
sgp30ebbrE18.b1:
sgp5ebbrE18.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
01/05/2005 | 1420 | 01/07/2005 | 1650 |
Subject: | SGP/EBBR/E20 - Wind Speed Frozen Stopped By Ice Storm |
DataStreams: | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
Description: | An ice storm froze the wind speed sensor to a stopped condition. The wind speed and residual wind speed measurements are incorrect. This sensor failure does not affect the sensible and latent heat fluxes. |
Measurements: | sgp5ebbrE20.b1:
sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
01/07/2005 | 0150 | 01/07/2005 | 1425 |
Subject: | SGP/EBBR/E20 - Wind Direction Frozen Stopped By Ice Storm |
DataStreams: | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
Description: | The wind direction sensor was frozen stopped by ice from a storm. The wind direction, sigma_wd, and residual wind speed measurements are incorrect. |
Measurements: | sgp5ebbrE20.b1:
sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
01/07/2005 | 0010 | 01/07/2005 | 1550 |
Subject: | SGP/EBBR/E18 - Wind Direction Frozen Stopped By Ice Storm |
DataStreams: | sgp30ebbrE18.b1, sgp5ebbrE18.b1, sgp15ebbrE18.b1 |
Description: | The wind direction sensor was frozen stopped by ice from a storm. The wind direction, sigma_wd, and residual wind speed measurements are incorrect. |
Measurements: | sgp15ebbrE18.b1:
sgp30ebbrE18.b1:
sgp5ebbrE18.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
03/30/2005 | 2000 | 04/13/2005 | 1700 |
Subject: | SGP/EBBR/E20 - Wrong Datalogger Program Installed |
DataStreams: | sgp30ebbrE20.b1 |
Description: | ts4 went offscale and sm4 dropped to a constant 16% when a "new" program was installed on 3/30/05. The wrong program was installed. Because ts4 did not change with time, it did not mess up the calculation of e and h. e and h are slightly overestimated, but only by about 1%, far less than the system error. This is a rare type of instrument problem where the concequences are minimal. Therefore, e and h are not listed as incorrect in this DQR and are still usable during the stated period. |
Measurements: | sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
03/20/2005 | 1230 | 04/27/2005 | 2000 |
Subject: | SGP/EBBR/E20 - Temp. of thum_left Incorrect At Times |
DataStreams: | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
Description: | The temperature portion of the left T/RH probe temperature spiked at times. This was caused by a faulty surge protector in the J-Panel. |
Measurements: | sgp5ebbrE20.b1:
sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
04/01/2001 | 0000 | 03/30/2005 | 0000 |
Subject: | SGP/EBBR/E18 - Improved EBBR CR10 Program |
DataStreams: | sgp30ebbrE18.b1 |
Description: | Effective 20050330.0000, the EBBR.E18 CR10 program was revised to improve the quality of the primary measurements as follows: 1) An RMS procedure is used to determine max and min limits of acceptable soil heat flow. This is applied to the individual soil sets. Measurements outside the limits are rejected and the measurements within the limits are used to calculate the average soil heat flow. 2) Max and min limits are used to determine incorrect values of net radiation, sensible heat flux (h), latent heat flux (e), and automatic exchange mechanism (AEM) signal. If AEM signal is outside the limits, h and e are set to 999s. If net radiation is outside the limits, h and e are set to 999s. If h or e are outside the limits, h and e are set to 999s. Virtually no incorrect soil measurement will affect the primary measurements of h and e. By setting h and e to 999s, it can be easily seen that the primary variables are incorrect; no other interpretation is possible. Prior to 20050330, the improved CR10 program was NOT in effect. DQRs have been submitted for known instances of incorrect soil measurements which affected the quality of the primary measurements of h and e. Note: the DQR begin date is the begin date of the sgp30ebbrE18.b1 data stream. The earlier version of the CR10 program was also used on previous EBBR datastream names (e.g. sgp30ebbrE18.a1). |
Measurements: | sgp30ebbrE18.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
04/01/2001 | 0000 | 03/30/2005 | 1900 |
Subject: | SGP/EBBR/E20 - Improved EBBR CR10 Program |
DataStreams: | sgp30ebbrE20.b1 |
Description: | Effective 20050330.1900, the EBBR.E20 CR10 program was revised to improve the quality of the primary measurements as follows: 1) An RMS procedure is used to determine max and min limits of acceptable soil heat flow. This is applied to the individual soil sets. Measurements outside the limits are rejected and the measurements within the limits are used to calculate the average soil heat flow. 2) Max and min limits are used to determine incorrect values of net radiation, sensible heat flux (h), latent heat flux (e), and automatic exchange mechanism (AEM) signal. If AEM signal is outside the limits, h and e are set to 999s. If net radiation is outside the limits, h and e are set to 999s. If h or e are outside the limits, h and e are set to 999s. Virtually no incorrect soil measurement will affect the primary measurements of h and e. By setting h and e to 999s, it can be easily seen that the primary variables are incorrect; no other interpretation is possible. Prior to 20050330, the improved CR10 program was NOT in effect. DQRs have been submitted for known instances of incorrect soil measurements which affected the quality of the primary measurements of h and e. Note: the DQR begin date is the begin date of the sgp30ebbrE20.b1 data stream. The earlier version of the CR10 program was also used on previous EBBR datastream names (e.g. sgp30ebbrE20.a1). |
Measurements: | sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
07/05/2005 | 1730 | 07/06/2005 | 1930 |
08/23/2005 | 1900 | 08/31/2005 | 1700 |
09/01/2005 | 1730 | 09/02/2005 | 0300 |
09/02/2005 | 1100 | 09/15/2005 | 2230 |
09/16/2005 | 0100 | 09/28/2005 | 1830 |
Subject: | SGP/EBBR/E20 - Soil Temperature and Soil Moisture #4 Measurements Incorrect |
DataStreams: | sgp15ebbrE20.b1, sgp30ebbrE20.b1 |
Description: | The ts4 sensor reported 99999 values because the sensor leads were loose. Soil moisture #4 reported low values (steady 16%) during this time period. The sensible and latent heat fluxes were not affected by this problem, only soil temperature and soil moisture #4. See soil temperatures and soil moistures from sets #2, #3, and #5 for correct values (note: soil temperature #1 was having problems during the same time). |
Measurements: | sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
07/27/2005 | 0730 | 08/03/2005 | 2100 |
Subject: | SGP/EBBR/E18 - Net Radiation Incorrect; Sensible and Latent Heat Fluxes Incorrect |
DataStreams: | sgp15ebbrE18.b1, sgp30ebbrE18.b1, sgp5ebbrE18.b1 |
Description: | The net radiometer top dome was broken and water got inside, making the net radiation, and sensible and latent heat flux measurements incorrect. |
Measurements: | sgp15ebbrE18.b1:
sgp30ebbrE18.b1:
sgp5ebbrE18.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
03/01/2005 | 2330 | 03/30/2005 | 0000 |
Subject: | SGP/EBBR/E18 - Average Soil Heat Flux Incorrect |
DataStreams: | sgp30ebbrE18.b1 |
Description: | A typo in the version 9 EBBR program caused average soil heat flow to be zero, resulting in both sensible and latent heat fluxes being approximately 20 watts per meter squared too large during the middle of the day. |
Measurements: | sgp30ebbrE18.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
03/02/2005 | 1900 | 03/30/2005 | 1900 |
Subject: | SGP/EBBR/E20 - Average Soil Heat Flux Incorrect |
DataStreams: | sgp30ebbrE20.b1 |
Description: | A typo in the version 9 EBBR program caused average soil heat flow to be zero, resulting in both sensible and latent heat fluxes being approximately 20 watts per meter squared too large during the middle of the day. |
Measurements: | sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/13/2003 | 0000 | 07/22/2005 | 2359 |
Subject: | SGP/EBBR/E18 - metadata corrections |
DataStreams: | sgp15ebbrE18.b1, sgp30ebbrE18.b1, sgp5ebbrE18.b1 |
Description: | On 20050723, a series of metadata corrections and additions were completed. These metadata changes apply to all EBBR.E18 data collected by ARM back to the installation of the instrument in July 1997. Please see the current metadata for correct information. These changes do not affect data values or quality. The changes are summarized below: 1) Update of "sensor location" information 2) Addition of installation dates for the systems 3) Correction of soil type 4) Correction of soil moisture units (from "by volume" to "gravimetric") |
Measurements: | sgp15ebbrE18.b1:
sgp30ebbrE18.b1:
sgp5ebbrE18.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/15/2003 | 0000 | 07/22/2005 | 2359 |
Subject: | SGP/EBBR/E20 - metadata corrections |
DataStreams: | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
Description: | On 20050723, a series of metadata corrections and additions were completed. These metadata changes apply to all EBBR.E20 data collected by ARM back to the installation of the instrument in April 1993. Please see the current metadata for correct information. These changes do not affect data values or quality. The changes are summarized below: 1) Update of "sensor location" information 2) Addition of installation dates for the systems 3) Correction of soil moisture units (from "by volume" to "gravimetric") |
Measurements: | sgp5ebbrE20.b1:
sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
12/21/2005 | 0930 | 12/21/2005 | 1730 |
Subject: | SGP/EBBR/E20 - Data Incorrect During J-Panel Replacement |
DataStreams: | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
Description: | Much of the data was incorrect during replacement of J-Panel #1. |
Measurements: | sgp5ebbrE20.b1:
sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
01/22/2006 | 0000 | 01/26/2006 | 0530 |
02/18/2006 | 0400 | 02/18/2006 | 2030 |
02/20/2006 | 0200 | 02/24/2006 | 1630 |
03/31/2006 | 0530 | 03/31/2006 | 0900 |
Subject: | SGP/EBBR/E18 - Wind Speed Zero |
DataStreams: | sgp15ebbrE18.b1, sgp30ebbrE18.b1, sgp5ebbrE18.b1 |
Description: | Wind Speed was zero, presumably because the sensor was frozen stopped during freezing rain. |
Measurements: | sgp15ebbrE18.b1:
sgp30ebbrE18.b1:
sgp5ebbrE18.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
02/22/2006 | 0300 | 02/25/2006 | 1630 |
Subject: | SGP/EBBR/E20 - Suspect Measurements |
DataStreams: | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
Description: | Some measurements may be incorrect because of low supply voltage. |
Measurements: | sgp5ebbrE20.b1:
sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
06/17/2006 | 0900 | 06/20/2006 | 1915 |
Subject: | SGP/EBBR/E20 - Net Radiation, Fluxes Too Large |
DataStreams: | sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
Description: | Net Radiation was way too large because of water in the bottom dome. This resulted in the sensible and latent heat fluxes being too large also. |
Measurements: | sgp5ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
05/31/2006 | 0430 | 06/02/2006 | 2130 |
Subject: | SGP/EBBR/E18 - Sensible and Latent Heat Fluxes and Net Radiation Incorrect |
DataStreams: | sgp15ebbrE18.b1, sgp30ebbrE18.b1, sgp5ebbrE18.b1 |
Description: | The net radiometer dome was cracked and water had gotten in, resulting in incorrect net radiation measurements and therefore incorrect sensible and latent heat flux measurements. |
Measurements: | sgp15ebbrE18.b1:
sgp30ebbrE18.b1:
sgp5ebbrE18.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/30/2006 | 2200 | 11/07/2006 | 2130 |
Subject: | SGP/EBBR/E18 - Sensible and Latent Heat Fluxes Incorrect |
DataStreams: | sgp30ebbrE18.b1 |
Description: | Sensible and latent heat fluxes were incorrect during this period because the AEM was not exchanging. |
Measurements: | sgp30ebbrE18.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
09/10/1997 | 2000 | 10/12/2003 | 2330 |
Subject: | SGP/EBBR/E18 - Wind Direction Dependency of Surface Fluxes and General Data Quality |
DataStreams: | sgp30ebbrE18.b1 |
Description: | Beginning in FY2006, Data Quality Reports are not written for missing data or for situations when qc flags clearly show that the data is incorrect (this is true for most of the conditions listed below). DQRs are written for periods when data is incorrect, when the situation is not represented by qc flags in the data, and it's not obvious that the data should have been flagged as incorrect. The EBBR data is only useful for particular wind directions at each Extended Facility. Please use the following resources to help in interpreting the EBBR data. 1) qc flags in the EBBR data. 2) Instrument Mentor Monthly Summaries (IMMS) at http://www.db.arm.gov/IMMS/ 3) SGP EF Surface Conditions Observations (EFSCO) at http://198.124.96.210:591/sfc_cond1/default.htm 4) Surface fluxes are valid only for the following wind directions (in degrees): 138-325 Note that there are wind directions at most sites for which the fetch is insufficient and therefore EBBR data is invalid. Appropriate fetch was determined from a 1/40 measurement height to fetch ratio, resulting in a required minimum fetch of 120 m. Particular attention should be paid to the limited valid wind directions for the Central Facility EBBR. The surface vegetation type for the EBBRs is grazed or ungrazed grassland (refer to the EFSCO for state). 5) Some conditions that commonly cause the EBBR primary measurements to be incorrect or missing follow: a) Sensible and latent heat fluxes are not accurate during times when the Automatic Exchange Mechanism (AEM) is not functioning properly. The AEM switches the gradient measuring instrumentation between the top and bottom positions every 15 minutes; this reduces the effects of instrument offsets. Sometimes the AEM does not reach it's full extent of travel, resulting in the home signal being zero. b) Sensible and latent heat fluxes are sometimes incorrect when surface soil heat flow is out of range, as seen in the average soil heat flux (ave_shf). c) Very light winds may be seen at nights for brief periods. Wind direction flops around a lot during low wind conditions (< 1.5 m/s) and is often unreliable during those periods. d) Missing data periods occur at times; this is usually a site data system collection/communication problem; it can also occur during replacement of the system with a newly calibrated unit. Missing data is sometimes filled in later from manual or automatic re-collection of the data. |
Measurements: | sgp30ebbrE18.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
07/06/1993 | 0630 | 10/04/2003 | 2330 |
Subject: | SGP/EBBR/E20 - Wind Direction Dependency of Surface Fluxes and General Data Quality |
DataStreams: | sgp30ebbrE20.b1 |
Description: | Beginning in FY2006, Data Quality Reports are not written for missing data or for situations when qc flags clearly show that the data is incorrect (this is true for most of the conditions listed below). DQRs are written for periods when data is incorrect, when the situation is not represented by qc flags in the data, and it's not obvious that the data should have been flagged as incorrect. The EBBR data is only useful for particular wind directions at each Extended Facility. Please use the following resources to help in interpreting the EBBR data. 1) qc flags in the EBBR data. 2) Instrument Mentor Monthly Summaries (IMMS) at http://www.db.arm.gov/IMMS/ 3) SGP EF Surface Conditions Observations (EFSCO) at http://198.124.96.210:591/sfc_cond1/default.htm 4) Surface fluxes are valid only for the following wind directions (in degrees): 0-230, 310-360 Note that there are wind directions at most sites for which the fetch is insufficient and therefore EBBR data is invalid. Appropriate fetch was determined from a 1/40 measurement height to fetch ratio, resulting in a required minimum fetch of 120 m. Particular attention should be paid to the limited valid wind directions for the Central Facility EBBR. The surface vegetation type for the EBBRs is grazed or ungrazed grassland (refer to the EFSCO for state). 5) Some conditions that commonly cause the EBBR primary measurements to be incorrect or missing follow: a) Sensible and latent heat fluxes are not accurate during times when the Automatic Exchange Mechanism (AEM) is not functioning properly. The AEM switches the gradient measuring instrumentation between the top and bottom positions every 15 minutes; this reduces the effects of instrument offsets. Sometimes the AEM does not reach it's full extent of travel, resulting in the home signal being zero. b) Sensible and latent heat fluxes are sometimes incorrect when surface soil heat flow is out of range, as seen in the average soil heat flux (ave_shf). c) Very light winds may be seen at nights for brief periods. Wind direction flops around a lot during low wind conditions (< 1.5 m/s) and is often unreliable during those periods. d) Missing data periods occur at times; this is usually a site data system collection/communication problem; it can also occur during replacement of the system with a newly calibrated unit. Missing data is sometimes filled in later from manual or automatic re-collection of the data. |
Measurements: | sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
07/10/2007 | 1500 | 09/12/2007 | 2045 |
Subject: | SGP/EBBR/E20 - Reprocess: Wind Direction 20 Degrees Low |
DataStreams: | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
Description: | The EBBR wind direction was found to be misaligned 20 degrees low. This bias should have had no effect on the res_ws or sigma_wd measurements. |
Measurements: | sgp5ebbrE20.b1:
sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/15/2007 | 0000 | 10/24/2007 | 1900 |
Subject: | SGP/EBBR/E20 - Reprocess: Wind Direction 65 Degrees Low |
DataStreams: | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
Description: | The wind direction sensor reported wind directions that were 65 degrees too low because of a mis-alignment. This bias should have no effect on the res_ws or sigma_wd measurements. The wind direction data could be re-processed by adding 65 degrees. |
Measurements: | sgp5ebbrE20.b1:
sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
04/08/2008 | 0600 | 05/07/2008 | 2000 |
Subject: | SGP/EBBR/E20 - Wind Direction 50 Degrees High |
DataStreams: | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
Description: | The wind direction was offset high about 50 degrees. |
Measurements: | sgp5ebbrE20.b1:
sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
04/15/2008 | 0030 | 05/06/2008 | 2110 |
Subject: | SGP/EBBR/E18 - Soil Heat Flow #4 Offscale Low; Sensible and Latent Heat Flux Sometimes |
DataStreams: | sgp15ebbrE18.b1, sgp30ebbrE18.b1 |
Description: | Soil heat flow #4 was sometimes lower than the lower limit imposed in the EBBR programming; sensible and latent heat flux were therefore deemed to be suspect during those times. The cause of the low values is not clear, but the values are not reasonable for the vegetation type at EF18. |
Measurements: | sgp15ebbrE18.b1:
sgp30ebbrE18.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
05/06/2008 | 1215 | 06/17/2008 | 2120 |
Subject: | SGP/EBBR/E18 - SHF #4 Measurements Too Low; Sensible and Latent Heat Fluxes Suspect |
DataStreams: | sgp15ebbrE18.b1, sgp30ebbrE18.b1 |
Description: | Soil heat flow #4 was replaced at the beginning of this period. However, the soil heat flow measurements from that sensor were sometimes still lower than the lower limit imposed in the EBBR programming; sensible and latent heat flux were therefore deemed to be suspect during those times. The cause of the low values could not be determined, but the values are not reasonable for the vegetation type at EF18. To remedy the situation, the soil heat flow sensor calibration was changed so that the sensor provided measurements that resembled the other four soil heat flow sensor measurements. Soil heat flow measurements have been reasonable since the calibration change. |
Measurements: | sgp15ebbrE18.b1:
sgp30ebbrE18.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
08/15/2008 | 0230 | 09/10/2008 | 2230 |
Subject: | SGP/EBBR/E20 - Wind Direction Incorrect |
DataStreams: | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
Description: | The wind direction differed from the co-located SMOS by 50 deg during part of the stated period and the electronics had failed completely resulting in a constant 135 degrees for the following dates and times: 08/15 0230-0430, 0830-1530 and 09/03 0200-0300, 0500 - 09/10 2230. Sensible and latent heat fluxes were not affected by this problem. |
Measurements: | sgp5ebbrE20.b1:
sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
01/26/2009 | 1910 | 01/27/2009 | 0800 |
Subject: | SGP/EBBR/E20 - Wind Speed Incorrect |
DataStreams: | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
Description: | The wind speed sensor was frozen stopped by freezing rain. |
Measurements: | sgp5ebbrE20.b1:
sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
01/26/2009 | 2150 | 01/29/2009 | 1550 |
Subject: | SGP/EBBR/E18 - Wind Speed Incorrect |
DataStreams: | sgp15ebbrE18.b1, sgp30ebbrE18.b1, sgp5ebbrE18.b1 |
Description: | The wind speed sensor was frozen stopped and thus wind speed was incorrect during this period. |
Measurements: | sgp15ebbrE18.b1:
sgp30ebbrE18.b1:
sgp5ebbrE18.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
04/12/2009 | 0305 | 04/22/2009 | 1400 |
Subject: | SGP/EBBR/E20 - Wind Direction Incorrect |
DataStreams: | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
Description: | The wind direction measurement was stuck at 40 degrees. |
Measurements: | sgp5ebbrE20.b1:
sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
01/28/2010 | 2030 | 02/01/2010 | 1930 |
Subject: | SGP/EBBR/E20 - Wind speed sensor frozen stopped |
DataStreams: | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
Description: | The wind speed sensor was frozen stopped by freezing rain. |
Measurements: | sgp5ebbrE20.b1:
sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
07/08/2010 | 0730 | 07/29/2010 | 1100 |
Subject: | SGP/EBBR/E20 - Incorrect Sensible and Latent Heat Fluxes |
DataStreams: | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
Description: | Because of a periodic AEM failure, home signal 30 was often stuck at the home signal 15 position. These occurrences resulted in incorrect latent and sensible heat flux values at times. Some missing data occurred because of low battery voltage (the CR10 program stops running when battery voltage is insufficient. The data outage events were preceded and followed by several hours of bad/suspicious data. |
Measurements: | sgp5ebbrE20.b1:
sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
07/09/2010 | 1030 | 08/04/2010 | 0200 |
Subject: | SGP/EBBR/E20 - Incorrect Sensible and Latent Heat Fluxes - a result of low battery |
DataStreams: | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
Description: | Supply voltage sometimes dropped too low at night, causing incorrect measurements of sensible and latent heat fluxes, pressure, AEM home signal, and soil heat flow. |
Measurements: | sgp5ebbrE20.b1:
sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
05/25/2011 | 1200 | 08/24/2011 | 1930 |
Subject: | SGP/EBBR/E20 - Sensible and latent heat fluxes overestimated |
DataStreams: | sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
Description: | Net Radiation was too large resulting in overestimated sensible heat and latent heat fluxes. |
Measurements: | sgp5ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
12/09/2011 | 1400 | 12/13/2011 | 1730 |
02/13/2012 | 0600 | 02/17/2012 | 1730 |
04/09/2012 | 2230 | 04/11/2012 | 0500 |
Subject: | SGP/EBBR/E36 - Missing Data |
DataStreams: | sgp15ebbrE36.b1, sgp30ebbrE36.b1, sgp5ebbrE36.b1 |
Description: | Data are missing and unrecoverable. |
Measurements: | sgp30ebbrE36.b1:
sgp5ebbrE36.b1:
sgp15ebbrE36.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
02/21/2012 | 1530 | 02/22/2012 | 2030 |
Subject: | SGP/EBBR/E36 - Sensible and Latent Heat Fluxes Incorrect |
DataStreams: | sgp15ebbrE36.b1, sgp30ebbrE36.b1 |
Description: | Sensible and latent heat fluxes were incorrect when soil heat flow #4 was incorrect. |
Measurements: | sgp30ebbrE36.b1:
sgp15ebbrE36.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
09/28/2011 | 0600 | 11/21/2011 | 1600 |
Subject: | SGP/EBBR/E32 - Sensible and latent heat fluxes incorrect |
DataStreams: | sgp30ebbrE32.b1 |
Description: | The AEM did not operate. Therefore sensible and latent heat fluxes were incorrect. |
Measurements: | sgp30ebbrE32.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
07/06/1993 | 0631 | 07/06/1993 | 0632 |
Subject: | EBBR - soil heat flux plate giving opposite sign |
DataStreams: | sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
Description: | EDITOR'S NOTE: This DQR refers to data collected by the EBBR at E20 prior to the begin date of regular ARM data. At that time, the data streams which contain the EBBR.E20 data were named Dsgp15ebbr6.a0 Dsgp30ebbr6.a1 Dsgp5ebbr6.a0 These data are not readily available from the ARM archive, but can be made available by special request. The actual time range of the problem described here is 930405.0000-930429.2359. Soil heat flux sensor #3 of EBBR6, at Meeker, Ok extended site was determined by me to have one heat flux plate whose output was out of phase with the other four. The absolute value of the soil heat flux value produced by the plate was good. Normally, this condition is caused either by improper wiring of the sensor into the data acquisition system (this was checked by site operations personnel on 29 April; wiring convention was correct) or by the plate being installed upside down. The latter seems fairly obvious, although the plate was not dug up to check it's orientation; that is not neccesary and would be detrimental since it takes time for such sensors to acclimate themselves to their soil environment. The consequence of this problem is that 5 soil heat flux plate outputs were being averaged, with one of the outputs being of opposite sign from the other four. Since the outputs are similar, in absolute terms, this essentially resulted in an average soil heat flux plate value that is 40% too low. In terms of output, this a reduction of around 10 W per meters squared, or 1-2% of the RN+G term during maximum solar insolation. This is clearly a small error. Site operations personnel switched the soil heat flux plate leads to give the proper sign of output, on 29 April 1993, time unknown (this can be determined from looking at the ingested data later; it hasn't been ingested yet). The instrument operated properly at that point. Thus, the problem has been corrected. |
Measurements: | sgp5ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/30/1993 | 1300 | 11/12/1993 | 1600 |
Subject: | SGP/EBBR/E20 - Blown fuse in AEM at E20 |
DataStreams: | sgp30ebbrE20.b1, sgp5ebbrE20.b1, sgp15ebbrE20.b1 |
Description: | On October 30, 1993, before 1300 GMT, the fuse in the AEM (Automatic Exchange Mechanism) of Meeker, Ok (E20) EBBR blew out. The AEM remained nonfunctional until the fuse was replaced just before 1600 GMT on November 12, 1993. This situation resulted in the following invalid data: 5 minute: tair_top, tair_bot, thum_top, thum_bot, hum_top, hum_bot, vp_top, vp_bot, home 15 minute: rr_thum_r, rr_thum_l, mv_hum_r, mv_hum_l, mv_home, tair_r, tair_l 30 minute: tair_top, tair_bot, thum_top, thum_bot, hum_top, hum_bot, vp_top, vp_bot, bowen, e, h, home_15, home_30 If the biases of the sensors were know, bowen, h, and e could be recalculated from the 15 minute and/or 5 minute data. Since we will not have any idea of what those biases are until an annual calibration of the sensors can take place (which may be months away), the recalculations cannot be performed at this time. Furthermore, it may be invalid to use sensor biases, if determined too far removed in time, due to the gradual calibration drift of some of the sensors. |
Measurements: | sgp5ebbrE20.b1:
sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
11/24/1993 | 1215 | 11/24/1993 | 1515 |
Subject: | SGP/EBBR/E20 - Reprocess: Questionable data in soil heat fluxes at E20 |
DataStreams: | sgp30ebbrE20.b1, sgp15ebbrE20.b1 |
Description: | Soil heat flux probes #4 had been indicating soil heat fluxes that were higher than the other four probes. It was decided to replace it. On November 24, 1993 Soil Heat Flux probe #4 was replaced, resulting in outputs more similar to the other four probes. This PIF does not invalidate previous measurements by the old probe #4, but only indicates data that is bad as a result of the replacement procedure. This procedure resulted in some bad data for the adjoining soil heat flux probes #3 and #5 also. Bad data for #3 includes the 1600 GMT half hour, and 5 and 15 minute periods between 1530 and 1600 GMT. Bad data for #4 includes half hour times of 1600 through 1900 GMT, with 5 and 15 minute data inbetween those times being invalid as well. Bad data for #5 includes half hour times of 1630 and 1700 GMT, with 5 and 15 minute periods inbetween those times being invalid as well. Corrupted 30 minute values of shf4, c_shf4, g4, ave_shf, h, and e, and corrupted 15 minute values of mv_hft4 resulted. The quantities shf4, c_shf4, g4, and mv_hft4 are bad data values and are not recoverable. The other quantities can be recalculated using the remaining functioning set(s) of soil sensors. Use the following equations: ave_shf = (gs summed)/n, where n is the number of probes functioning e = -(q + ave_shf)/(1 + bowen) where q is net radiation, and bowen is Bowen Ratio h = e * bowen |
Measurements: | sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
03/17/1994 | 1600 | 03/17/1994 | 1630 |
Subject: | SGP/EBBR/E20 - Pressure Sensor Malfunction |
DataStreams: | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
Description: | Pressure sensor malfunction during attempt to monitor it during Preventative Maintenance visit. 30 minute values of pressure for 1600 GMT and 1630 GMT, 15 minute values for 1600, 1615, and 1630, and 5 minute values for 1600, 1605, 1610, 1615, 1620, 1625, and 1630 GMT are incorrect. However, the range of the incorrect values was such as to not adversely affect flux measurements. Some noise was apparently induced in the pressure output voltage as a result of the monitoring, although it is not known how. |
Measurements: | sgp5ebbrE20.b1:
sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
05/06/1994 | 1600 | 06/09/1994 | 1545 |
Subject: | SGP/EBBR/E20 - Soil Moisture Probe |
DataStreams: | sgp15ebbrE20.b1, sgp30ebbrE20.b1 |
Description: | Beginning on May 6, 1994, soil moisture probe #3 began a long decline in output and sensitivity until it stabilized at a low value of around 7, with virtually no sensitivity at midday (GMT) on May 22, 1994. The output remained around this low value until the probe was replaced on June 9, 1994 at 1545 GMT. Old Probe S/N 92038, New Probe S/N 93003. |
Measurements: | sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
09/12/1994 | 1300 | 09/14/1994 | 1847 |
Subject: | SGP/EBBR/E20 - Fan Stopped, T and RH Biases |
DataStreams: | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
Description: | Another fan stoppage situation occurred. This is the fourth one in the last few months and may indicate a weakening of the fans that aspirate the temperature, relative humidity housings. The 15 minute data reveals that the stoppage occurred at approximately 1300 GMT on September 12. The left fan was cleaned out by site operations personnel and began running again at 1847 GMT on September 14. The 15 minute data during this period shows that during daytime, the left temperature was greater than the right temperature and that the left relative humidity was lower than the right relative humidity (a consequence of greater temperature), irregardless of the positions of the housings. The bowen ratio, sensible heat flux and latent heat flux for this period, as well as all left housing temperatures and relative humidities are incorrect. The data values that are incorrect are: 5 minute: tair_top, tair_bot, thum_top, thum_bot, hum_top, hum_bot, vp_top, vp_bot 15 minute: rr_thum_l, mv_hum_l, tair_l, 30 minute: tair_top, tair_bot, thum_top, thum_bot, hum_top, thum_bot, vp_top, vp_bot, bowen, e, h Because of the increased frequency of fan stoppage occurrences, I have submitted a work request to site operations to use the portable vane anemometer to check the flow of the housing fans on each EBBR and visually check (and clean if needed) the fans for debris that would restrict the flow. Included in this work request are instructions for checking the performance of the temperature and relative humidity sensors by manually putting the aspirator housings at the same height for a half hour period (so that two 15 minute and one half hour comparison result). The latter part of the work request is prompted by my close inspection of the Meeker data for the last few weeks. It is clear that significant biases have developed in the pairs of temperature and relative humidity sensors; left thermocouple ~0.5 deg. C greater than right thermocouple, left relative humidity ~5% lower than right relative humidity. Biases were expected in operating the systems over long time periods, and these appear to be the result of simple offsets, not changes in calibrations. At this point, I just want to determine how large the offsets are. Comparison of these offsets between EBBR units, in light of the different lengths of time that EBBR units and individual sensors have been deployed, may provide some interesting information on likely offset changes with time. |
Measurements: | sgp5ebbrE20.b1:
sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
09/29/1994 | 1530 | 09/29/1994 | 1600 |
Subject: | SGP/EBBR/E20 - Soil Moisture Probe Failure |
DataStreams: | sgp15ebbrE20.b1, sgp30ebbrE20.b1 |
Description: | Soil moisture probe #4 went offscale for a short period, for unknown reasons. However, it may have resulted from Site Operations Preventative Maintenance activities that were taking place at the time. The times of incorrect values are listed below. 30 minute: 1600 GMT; sm4, c_shf4, cs4, ces4, g4, ave_shf, e, h 15 minute: 1600 GMT; r_sm4 |
Measurements: | sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
09/29/1994 | 1530 | 09/29/1994 | 1730 |
Subject: | SGP/EBBR/E20 - Aspirator Fan Stoppage |
DataStreams: | sgp15ebbrE20.b1, sgp30ebbrE20.b1 |
Description: | During Site Operations Preventative Maintenance activities the left AEM fan stopped operating. This affected some of the data being collected. The times of incorrect values are listed below. 15 minute: 1530-1715 GMT; tair_l, mv_hum_l, rr_thum_l 30 minute: 1530-1730 GMT; thum_top, thum_bot, tair_top, tair_bot, hum_top, hum_bot, e, h, bowen |
Measurements: | sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
09/29/1994 | 1715 | 09/29/1994 | 1800 |
Subject: | SGP/EBBR/E20 - Net Radiometer Hemisphere Changes |
DataStreams: | sgp30ebbrE20.b1, sgp15ebbrE20.b1, sgp5ebbrE20.b1 |
Description: | Incorrect data during hemisphere change. |
Measurements: | sgp5ebbrE20.b1:
sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
09/14/1994 | 1600 | 09/29/1994 | 1735 |
Subject: | SGP/EBBR/E20 - Net Radiometer Hemisphere Changes |
DataStreams: | sgp30ebbrE20.b1, sgp15ebbrE20.b1, sgp5ebbrE20.b1 |
Description: | The upper hemisphere of the net radiometer at the site was punctured allowing water to collect in the lower (and sometimes upper) section of the sensor. The punctures are most likely the result of migratory birds (a problem that we have experienced almost every year here at ANL also). The punctures (and water in some net radiometers) did not result in obvious invalidation of the data. Whether there is water in the lower hemisphere or not, a small puncture of the upper hemisphere would not have a major effect on the net radiation measurement. Significant amounts of water in the lower hemisphere should have a major effect on nighttime measurements particularly, although that effect is hard to detect in the data. The date when the puncture occurred is approximate - but is certainly no more than two weeks before the hemisphere was replaced. |
Measurements: | sgp5ebbrE20.b1:
sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
03/07/1995 | 0555 | 03/07/1995 | 2145 |
Subject: | SGP/EBBR/E20 - Frozen Wind Speed Sensor |
DataStreams: | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
Description: | On March 7, 1995 freezing rain stopped the cups of the EBBR wind speed instrument at Meeker, OK (E20). All 5, 15, and 30 minute data values indicated below are incorrect for the period listed above. 5 minute: wind_s, res_ws 15 minute: wind_s 30 minute: wind_s, res_ws |
Measurements: | sgp5ebbrE20.b1:
sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
07/18/1995 | 0400 | 07/18/1995 | 1400 |
07/19/1995 | 0430 | 07/19/1995 | 0500 |
07/19/1995 | 0730 | 07/19/1995 | 1500 |
07/29/1995 | 0700 | 07/29/1995 | 1630 |
Subject: | SGP/EBBR/E20 - Reprocess: Soil Temperature Malfunction |
DataStreams: | sgp15ebbrE20.b1, sgp30ebbrE20.b1 |
Description: | During parts of three days, soil temperature probe #4 indicated values that were either too high or too low, for unknown reasons. Site Operations personnel checked connections and repacked the soil around the probe on 21 July at about 1535 GMT, although ts4 had recovered to proper values the previous day. The times of incorrect data and the affected quantities are shown below. Some of the ts4 values during the listed periods appear to be correct, although the change in energy storage values appear to indicate otherwise. 18 July: 0400-1400 GMT 19 July: 0430-0500, 0730-1500 GMT 29 July: 0700-1630 GMT 15 minute: rr_ts4 30 minute: ts4, ces4, g4, ave_shf, e, h Sensible, latent, and soil heat fluxes need to be recalculated using the change in energy storage of probes 1-3 and 5, as follows. ave_shf = (g1 + g2 + g3 + g5)/4 e = -(q + ave_shf)/(1 +bowen) h = -(e + ave_shf +q) |
Measurements: | sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
08/09/1995 | 0930 | 08/09/1995 | 2030 |
Subject: | SGP/EBBR/E20 - Annual Calibration Changeout |
DataStreams: | sgp30ebbrE20.b1 |
Description: | On August 9, 1995 between 0930-2030 GMT, the changeout for annual calibration occurred at E20, Meeker, OK. Soil measurements data should be used with caution for the following week at least, as the sensors require time to "settle" into the soil. |
Measurements: | sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
08/09/1995 | 2030 | 08/16/1995 | 2359 |
Subject: | SGP/EBBR/E20 - AEM Home 30 Values Low |
DataStreams: | sgp5ebbrE20.b1, sgp30ebbrE20.b1 |
Description: | The first EBBR to achieve annual calibration changeout was Meeker, Ok, E20. However, soon after changeout on August 9, 1995, the home 30 value dropped below 15, intermittently, to typically 0.3 to 0.5; this causes a data quality message to be output in the site operations log as the stated acceptable range for home 30 is 15 to 34.999999. However, no data is incorrect as a result of this condition. No replacement AEM is available, as the changeout kit AEMs are somewhat different from the initial units. Site operations hopes to have time to diagnose the problem on the next PM visit and correct the problem. At present, data quality is not jeopardized. I will submit another DQR or addendum when successful replacement of the AEM is accomplished. |
Measurements: | sgp5ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
11/10/1995 | 0030 | 11/10/1995 | 1530 |
Subject: | SGP/EBBR/E20 - Soil Heat Flow Zero Under Unchanging Conditions |
DataStreams: | sgp30ebbrE20.b1 |
Description: | This DQR is written to inform users of the data that the EBBR soil heat flow measurements of zero during much of 11 November 1995 at E20, Meeker, OK are correct values. Nearly unchanging conditions of net radiation, air temperature, and soil moisture, plus high wind speeds and near neutral atmospheric stability, resulted in almost unchanging conditions of soil temperature and ten and a half hours of zero soil heat flow output from all soil heat flow plates (some plates outputted zero for longer than this). The change in energy storage (determined from the change in temperature with time of the soil above the plates) was very nearly zero also during the period of interest. Such an extended period of zero soil heat flow and the accompanying unchanging soil and atmospheric conditions is quite rare and therefore worth noting here in case someone using the data might mistakenly think that the data is incorrect. |
Measurements: | sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
11/11/1995 | 0300 | 11/11/1995 | 1600 |
Subject: | SGP/EBBR/E20 - AEM Exchange Stopped in Snow and Freezing Rain |
DataStreams: | sgp30ebbrE20.b1 |
Description: | On the night of November 10-11, a north-south line from south central Kansas through south central Oklahoma received snow and freezing rain and experienced below freezing temperatures. This caused the EBBR automatic exchange mechanism (AEM) to stop exchanging temporarily. Note that temperatures, relative humidities, and vapor pressures are not affected; these are correct as measured, but the height at which the measurements occurred must be determined from the home signal value. |
Measurements: | sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/01/1995 | 0000 | 05/08/1996 | 1755 |
Subject: | SGP/EBBR/E20 - Temperature/RH Probes Malfunction and Replacement |
DataStreams: | sgp30ebbrE20.b1, sgp5ebbrE20.b1, sgp15ebbrE20.b1, sgp5ebbrE20.00 |
Description: | Beginning on approximately October 1, 1996 the calibration of the temperature sensor in one or both T/RH probes began to drift; temperatures started to drift higher than the thermocouple probes. This drift caused the upper and lower temperatures measured by the T/RH probe to be 2 to 10 degrees C greater than the thermocouple probes. Comparison with adjacent EBBR sites shows that the thermocouples were measuring properly. The problem affected the vapor pressure outputs primarily, making them as much as 1 kPa greater than they should be (vapor pressure is calculated from probe temperature and relative humidity). The effect on sensible and latent heat fluxes was negligible, although latent heat flux may be overestimated by about 5% presently and sensible heat flux underestimated by approximately the same percentage. Site operations replaced the T/RH probes on 8 May 1996; the new probes are performing well. The serial numbers of replaced probes are: Left 632415, Right 632356. New probe serial numbers are: Left 460428, Right 460412. |
Measurements: | sgp5ebbrE20.b1:
sgp5ebbrE20.00:
sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
04/10/1996 | 1500 | 04/10/1996 | 1830 |
Subject: | SGP/EBBR/E20 - 3-month check |
DataStreams: | sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
Description: | During EBBR 3-month checks the Automatic Exchange Mechanism is disabled (reflected by home signals near zero) so that the two aspirator units can be placed at the same height. The measurements during this period, at least, do not produce correct outputs of bowen ratio (bowen), sensible heat flux (h), or latent heat flux (e), nor do the air temperature and relative humidity measurements indicate gradients. Checks performed before or after the AEM is disabled also lead to some incorrect data. The period of incorrect data for the EBBR is listed above; data times affected do not include the beginning time and do include the ending time (data files are denoted by the end time). |
Measurements: | sgp5ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
05/08/1996 | 2145 | 06/19/1996 | 1700 |
Subject: | SGP/EBBR/E20 - Incorrect Data from Left Humidity Probe |
DataStreams: | sgp30ebbrE20.b1, sgp15ebbrE20.b1 |
Description: | The left humidity probe output started drifting upward at 2145 GMT on May 8, 1996 and went offscale (over 105%) at 0200 GMT on May 9, 1996. The output settled at approximately 113% and remained there until the probe was replaced on June 19, 1996. The first correct 15 minute values were at 1630 GMT on June 19 and the first correct 30 minute values were at 1700 GMT. During the period of incorrect left probe RH data, the following values were incorrect: 15 minute: mv_hum_l 30 minute: hum_top, hum_bot, vp_top, vp_bot, h, e, bowen. |
Measurements: | sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/23/1996 | 1730 | 10/23/1996 | 1755 |
Subject: | SGP/EBBR/E20 - EBBR 3 Month Checks - 10 EFs |
DataStreams: | sgp30ebbrE20.b1, sgp15ebbrE20.b1, sgp5ebbrE20.b1 |
Description: | During EBBR 3 month checks the Automatic Exchange Mechanism is disabled (reflected by home signals near zero) so that the two aspirator units can be placed at the same height. The measurements during these periods do not produce correct outputs of bowen ratio (bowen), sensible heat flux (h), or latent heat flux (e), nor do the air temperature and relative humidity measurements indicate correct gradients. Checks performed before or after the AEM is disabled also lead to some incorrect data. Incorrect 5, 15 minute and half hour data occurs for periods indicated. |
Measurements: | sgp5ebbrE20.b1:
sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
11/24/1996 | 1010 | 11/25/1996 | 1805 |
Subject: | SGP/EBBR/E20 - Wind Speed Cups Frozen |
DataStreams: | sgp30ebbrE20.b1, sgp5ebbrE20.b1, sgp15ebbrE20.b1 |
Description: | Freezing rain, snow, and below freezing conditions during 24 November 1996 caused the wind speed sensor cups to freeze in a stopped state at E20, Meeker, OK. On 25 November, the cups broke free of the ice and turned freely again. Measurements affected by the stalled wind speed sensor include: 5 minute: wind_s, res_ws 15 minute: wind_s 30 minute: wind_s, res_ws |
Measurements: | sgp5ebbrE20.b1:
sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
06/11/1997 | 0000 | 07/16/1997 | 2359 |
Subject: | SGP/EBBR/E20 - Reprocess: E20 Soil Probes #3 Cables Cut |
DataStreams: | sgp15ebbrE20.b1, sgp30ebbrE20.b1 |
Description: | The cables going to #3 soil temperature, moisture, and heat flow probes were cut by a mower on 11 June 1997 and were repaired on 16 July 1997. Data for the temperature probe was offscale, for the soil moisture probe was a constant 10.1 (close to the actual), and for the soil heat flow was large negative during the period. The following are the data quantities that were affected: 15 minute: rr_ts3, mv_hft3, r_sm3 30 minute: ts3, ces3, shf3, c_shf3, cs3, g3, ave_shf, e, h Sensible, latent, and soil heat fluxes can be recalculated using the values from probes 1, 2, 4, and 5, as follows. ave_shf = (g1 + g2 + g4 + g5)/4 e = -(q + ave_shf)/(1 +bowen) h = -(e + ave_shf +q) |
Measurements: | sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
04/09/1997 | 2120 | 04/09/1997 | 2144 |
Subject: | SGP/EBBR/E20 - EBBR Biannual Checks |
DataStreams: | sgp30ebbrE20.b1, sgp15ebbrE20.b1, sgp5ebbrE20.b1 |
Description: | During EBBR 3 month checks the Automatic Exchange Mechanism is disabled (reflected by home signals near zero) so that the two aspirator units can be placed at the same height. The measurements during these periods do not produce correct outputs of bowen ratio (bowen), sensible heat flux (h), or latent heat flux (e), nor do the air temperature and relative humidity measurements indicate correct gradients. Checks performed before or after the AEM is disabled also lead to some incorrect data. Incorrect 5, 15 minute and half hour data occurs for periods indicated. |
Measurements: | sgp5ebbrE20.b1:
sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
09/10/1997 | 2000 | 10/23/1997 | 1700 |
Subject: | SGP/EBBR/E18 - Left RH Probe Temperature Incorrect |
DataStreams: | sgp15ebbrE18.b1, sgp30ebbrE18.b1 |
Description: | The left humidity probe temperature produced incorrect values from the time of installation of the E18 EBBR until 23 October at 1700 GMT because of a poor connection. |
Measurements: | sgp15ebbrE18.b1:
sgp30ebbrE18.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
01/08/1998 | 0330 | 01/08/1998 | 1940 |
Subject: | SGP/EBBR/E20- EBBR Frozen Wind Speed |
DataStreams: | sgp5ebbrE20.b1, sgp30ebbrE20.b1, sgp15ebbrE20.b1 |
Description: | Wind speed cups were frozen during the indicated time periods. All 5, 15, and 30 minute data values indicated are incorrect for the periods listed. |
Measurements: | sgp5ebbrE20.b1:
sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
01/08/1998 | 1100 | 01/14/1998 | 1545 |
Subject: | SGP/EBBR/E20 - EBBR AEMs Not Exchanging (Iced Or Fuse Blown) |
DataStreams: | sgp30ebbrE20.b1, sgp5ebbrE20.b1, sgp15ebbrE20.b1 |
Description: | The EBBR AEM stopped exchanging because of icing at during this time period. The calculations of Bowen ratio, latent heat flux, and sensible heat flux are incorrect for the time period indicated. The other measurements listed are also incorrect for those times: Note: Mentor supplied the end date/time to this DQR after submission. |
Measurements: | sgp5ebbrE20.b1:
sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
01/13/1998 | 0330 | 01/15/1998 | 1630 |
Subject: | SGP/EBBR/E20 - Wind Speed Sensor Frozen |
DataStreams: | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1, sgp5ebbrE20.00 |
Description: | The wind speed sensor was frozen during the period. Data values that were incorrect are: 5 minute: wind_s, res_ws 15 minute: wind_s 30 minute: wind_s, res_ws |
Measurements: | sgp5ebbrE20.b1:
sgp5ebbrE20.00:
sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/23/1997 | 1355 | 10/23/1997 | 1420 |
Subject: | SGP/EBBR/E18 - 3 Month Check |
DataStreams: | sgp15ebbrE18.b1, sgp30ebbrE18.b1, sgp5ebbrE18.b1 |
Description: | During EBBR 3 month checks the Automatic Exchange Mechanism is disabled (reflected by home signals near zero) so that the two aspirator units can be placed at the same height. The measurements during these periods do not produce correct outputs of bowen ratio (bowen), sensible heat flux (h), or latent heat flux (e), nor do the air temperature and relative humidity measurements indicate correct gradients. Checks performed before or after the AEM is disabled also lead to some incorrect data. Incorrect 5, 15 minute and half hour data occurs for the period above. |
Measurements: | sgp15ebbrE18.b1:
sgp30ebbrE18.b1:
sgp5ebbrE18.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/22/1997 | 1645 | 10/22/1997 | 1705 |
Subject: | SGP/EBBR/E20 - 3 Month Check |
DataStreams: | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
Description: | During EBBR 3 month checks the Automatic Exchange Mechanism is disabled (reflected by home signals near zero) so that the two aspirator units can be placed at the same height. The measurements during these periods do not produce correct outputs of bowen ratio (bowen), sensible heat flux (h), or latent heat flux (e), nor do the air temperature and relative humidity measurements indicate correct gradients. Checks performed before or after the AEM is disabled also lead to some incorrect data. Incorrect 5, 15 minute and half hour data occurs for the period above. |
Measurements: | sgp5ebbrE20.b1:
sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
05/21/1998 | 1402 | 05/21/1998 | 1430 |
Subject: | SGP/EBBR/E18 - Six Month Checks |
DataStreams: | sgp15ebbrE18.b1, sgp30ebbrE18.b1, sgp5ebbrE18.b1 |
Description: | During EBBR 6 month checks (formally called 3 month checks) the Automatic Exchange Mechanism is disabled (reflected by home signals near zero) so that the two aspirator units can be placed at the same height. The measurements during these periods do not produce correct outputs of bowen ratio (bowen), sensible heat flux (h), or latent heat flux (e), nor do the air temperature and relative humidity measurements indicate correct gradients. Checks performed just before or after the AEM is disabled also lead to some incorrect data. Incorrect 5, 15 minute and half hour data occurs for the period above. |
Measurements: | sgp15ebbrE18.b1:
sgp30ebbrE18.b1:
sgp5ebbrE18.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
05/20/1998 | 1450 | 05/20/1998 | 1530 |
Subject: | SGP/EBBR/E20 - Six Month Checks |
DataStreams: | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
Description: | During EBBR 6 month checks (formally called 3 month checks) the Automatic Exchange Mechanism is disabled (reflected by home signals near zero) so that the two aspirator units can be placed at the same height. The measurements during these periods do not produce correct outputs of bowen ratio (bowen), sensible heat flux (h), or latent heat flux (e), nor do the air temperature and relative humidity measurements indicate correct gradients. Checks performed just before or after the AEM is disabled also lead to some incorrect data. Incorrect 5, 15 minute and half hour data occurs for the period above. |
Measurements: | sgp5ebbrE20.b1:
sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
09/10/1997 | 2000 | 06/18/1998 | 1420 |
Subject: | SGP/EBBR/E18 - Reprocess: E18 EBBR Net Radiometer Calibration |
DataStreams: | sgp30ebbrE18.b1, sgp5ebbrE18.b1 |
Description: | When the CR10 program was loaded in the storage module of the newly installed EBBR unit at E18 on 10 September 1997, an incorrect calibration for the net radiometer was present. The incorrect calibration had apparently been entered into the storage module by the vendor before the unit was shipped. The .DOC file showed the correct calibration; therefore, we did not suspect a problem until comparisons with radiometers at other sites nearby were performed. The program with the correct calibration was entered on 18 June 1998. The 15 minute mv_q values were not affected. The 5 and 30 minute q values during the period above need to be corrected; multiply positive q values by 0.684, multiply negative values by 0.811; Sensible (h) and Latent Heat (e) fluxes for the period need to be recalculated with the equations below. e = -(q + ave_shf)/(1 + bowen) h = -(e + ave_shf + q) |
Measurements: | sgp30ebbrE18.b1:
sgp5ebbrE18.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
07/03/1998 | 1115 | 07/15/1998 | 1930 |
Subject: | SGP/EBBR/E20 - Wind Speed Incorrect |
DataStreams: | sgp5ebbrE20.b1, sgp15ebbrE20.b1, sgp30ebbrE20.b1 |
Description: | On 3 July 1998 the cup anemometer lost a cup. Until the cup assembly was replaced by site ops personnel on 15 July 1998, wind speed and vector averaged wind speed data were incorrect. The values affected are listed below. 5 minute: wind_s, res_ws 15 minute: wind_s 30 minute: wind_s, res_ws |
Measurements: | sgp5ebbrE20.b1:
sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/19/1998 | 2215 | 10/21/1998 | 1600 |
Subject: | SGP/EBBR/E20 - Incorrect Data - Cattle Vandalism |
DataStreams: | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
Description: | Cattle penetrated the electric fence and pulled the aspirator housings from the AEM. Thus T/RH/VP and sensible and latent heat fluxes are incorrect for the period (until 1540 GMT; LE and H through the 30 minute period ending at 1600 GMT) |
Measurements: | sgp5ebbrE20.b1:
sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
11/15/1998 | 0100 | 11/17/1998 | 2100 |
Subject: | SGP/EBBR/E18 - Water In Net Radiometer, Flux Data Incorrect |
DataStreams: | sgp15ebbrE18.b1, sgp30ebbrE18.b1, sgp5ebbrE18.b1 |
Description: | Incorrect Net Radiation values resulted from water in the bottom dome. Thus incorrect sensible and latent heat fluxes resulted. Affected values are: 5 minute: q 15 minute: mv_q 30 minute: q, e, h |
Measurements: | sgp15ebbrE18.b1:
sgp30ebbrE18.b1:
sgp5ebbrE18.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
12/21/1998 | 1635 | 12/23/1998 | 2000 |
Subject: | SGP/EBBR/E18 - Wind Direction Data Incorrect (revised) |
DataStreams: | sgp15ebbrE18.b1, sgp30ebbrE18.b1, sgp5ebbrE18.b1, sgp5ebbrE18.00 |
Description: | The wind direction sensor was iced stopped by freezing rain, resulting in the following values being incorrect: 5 minute: res_ws, wind_d, sigma_wd 15 minute: mv_wind_d 30 minute: res_ws, wind_d, sigma_wd |
Measurements: | sgp15ebbrE18.b1:
sgp30ebbrE18.b1:
sgp5ebbrE18.b1:
sgp5ebbrE18.00:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
12/21/1998 | 1435 | 12/23/1998 | 0200 |
Subject: | SGP/EBBR/E20 - Wind Direction Data Incorrect (revised) |
DataStreams: | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
Description: | The wind direction sensor was iced stopped by freezing rain, resulting in the following values being incorrect: 5 minute: res_ws, wind_d, sigma_wd 15 minute: mv_wind_d 30 minute: res_ws, wind_d, sigma_wd |
Measurements: | sgp5ebbrE20.b1:
sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
01/08/1999 | 1005 | 01/08/1999 | 1730 |
Subject: | SGP/EBBR/E20 - Wind Direction Data Incorrect |
DataStreams: | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
Description: | The wind direction sensor was iced stopped by freezing rain, resulting in the following values being incorrect: 5 minute: res_ws, wind_d, sigma_wd 15 minute: mv_wind_d 30 minute: res_ws, wind_d, sigma_wd |
Measurements: | sgp5ebbrE20.b1:
sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
12/21/1998 | 1005 | 12/22/1998 | 2000 |
Subject: | SGP/EBBR - EBBR E18 Wind Speed Data Incorrect |
DataStreams: | sgp15ebbrE18.b1, sgp30ebbrE18.b1, sgp5ebbrE18.b1, sgp5ebbrE18.00 |
Description: | The wind speed sensor was iced stopped by freezing rain, resulting in the following values being incorrect: 5 minute: wind_s, res_ws 15 minute: wind_s 30 minute: wind_s, res_ws, |
Measurements: | sgp15ebbrE18.b1:
sgp30ebbrE18.b1:
sgp5ebbrE18.b1:
sgp5ebbrE18.00:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
01/02/1999 | 0805 | 01/02/1999 | 1800 |
Subject: | SGP/EBBR/E18 - Wind Speed Data Incorrect |
DataStreams: | sgp15ebbrE18.b1, sgp30ebbrE18.b1, sgp5ebbrE18.b1, sgp5ebbrE18.00 |
Description: | The wind speed sensor was iced stopped by freezing rain, resulting in the following values being incorrect: 5 minute: wind_s, res_ws 15 minute: wind_s 30 minute: wind_s, res_ws, |
Measurements: | sgp15ebbrE18.b1:
sgp30ebbrE18.b1:
sgp5ebbrE18.b1:
sgp5ebbrE18.00:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
01/08/1999 | 1015 | 01/10/1999 | 1300 |
Subject: | SGP/EBBR/E18 - Wind Speed Data Incorrect |
DataStreams: | sgp15ebbrE18.b1, sgp30ebbrE18.b1, sgp5ebbrE18.b1, sgp5ebbrE18.00 |
Description: | The wind speed sensor was iced stopped by freezing rain, resulting in the following values being incorrect: 5 minute: wind_s, res_ws 15 minute: wind_s 30 minute: wind_s, res_ws, |
Measurements: | sgp15ebbrE18.b1:
sgp30ebbrE18.b1:
sgp5ebbrE18.b1:
sgp5ebbrE18.00:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
01/08/1999 | 0545 | 01/09/1999 | 2200 |
Subject: | SGP/EBBR/E20 - Wind Speed Data Incorrect |
DataStreams: | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
Description: | The wind speed sensor was iced stopped by freezing rain, resulting in the following values being incorrect: 5 minute: wind_s, res_ws 15 minute: wind_s 30 minute: wind_s, res_ws, |
Measurements: | sgp5ebbrE20.b1:
sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
12/21/1998 | 0735 | 12/21/1998 | 2000 |
Subject: | SGP/EBBR/E20 - Wind Speed Data Incorrect |
DataStreams: | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
Description: | The wind speed sensor was iced stopped by freezing rain, resulting in the following values being incorrect: 5 minute: wind_s, res_ws 15 minute: wind_s 30 minute: wind_s, res_ws, |
Measurements: | sgp5ebbrE20.b1:
sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
11/25/1998 | 1735 | 12/29/1998 | 1630 |
Subject: | SGP/EBBR/E20 - Data Incorrect |
DataStreams: | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1, sgp5ebbrE20.00 |
Description: | Version 6 of the CR10 program was installed during this period instead of version 7 (the initial version 7 program did not work). The calibrations and coefficients in version 6 were incorrect; therefore all data during this period is of questionable quality and e and h are clearly incorrect. The correct version 7 program was installed on 29 Dec 1998. |
Measurements: | sgp5ebbrE20.b1:
sgp5ebbrE20.00:
sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
01/13/1999 | 2150 | 02/10/1999 | 1640 |
Subject: | SGP/EBBR/E20 - Pressure Low |
DataStreams: | sgp5ebbrE20.b1, sgp15ebbrE20.b1, sgp30ebbrE20.b1 |
Description: | The pressure sensor values dropped several kPa on 13 January 1999 because of a sensor malfunction and remained that way until the sensor was replaced on 10 February 1999. Comparison of the pressure before and after the problem period shows that Bowen ratio was underestimated by approximately 6% during the period, resulting in a 6% overestimation of latent heat flux and a 6% underestimation of sensible heat flux. Adjustment of the flux data during the period by these amounts should be made by the data user. |
Measurements: | sgp5ebbrE20.b1:
sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
03/25/1999 | 0040 | 04/07/1999 | 1745 |
Subject: | SGP/EBBR/E20 - Air Temperature Incorrect |
DataStreams: | sgp15ebbrE20.b1, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
Description: | Right air temperature (15 minute) and top and bottom air temperatures (5 and 30 minute) during this period are incorrect because the right air temperature sensor was not working. |
Measurements: | sgp5ebbrE20.b1:
sgp15ebbrE20.b1:
sgp30ebbrE20.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/08/1997 | 2030 | 06/17/1999 | 1600 |
Subject: | SGP/EBBR/E18 - Pressure Incorrect |
DataStreams: | sgp30ebbrE18.b1, sgp5ebbrE18.b1, sgp5ebbrE18.00 |
Description: | The pressure sensor was replaced at E18 EBBR without the replacement being noted by Site Ops and therefore without an indication of serial number and thus correct calibration. The serial number of the sensor was observed during a PM (after months of confusion concerning the thing) and a several month search for the calibration sheet at ANL, the CF, and the manufacturer ensued. The sheet was finally found and I confirmed that an incorrect offset was being used (the same as used for the previous sensor). This is an easy error to make as there are two models of pressure sensors (with different calibration ranges) being used in the EBBR systems. On June 17, 1999 the correct offset was entered into the CR10 and storage module programming. The pressure for the period should be increased by 6.757 kPa. The result of the error is that Bowen ratio was underestimated by 6.8% on average, Latent Heat Flux was overestimated by 3.6% on average, and Sensible Heat Flux was underestimated by 3.6% on average. The errors in the fluxes are smaller than the estimated 10% error in the Bowen ratio flux measurement technique and therefore the data does not need to be reprocessed. Anyone performing area averages of pressure or looking at the variation in pressure over the CART Site should adjust the E18 EBBR pressure values for this period using the offset error indicated above. |
Measurements: | sgp30ebbrE18.b1:
sgp5ebbrE18.b1:
sgp5ebbrE18.00:
|