Data Quality Reports for Session: 143394 User: spowell Completed: 06/28/2012


TABLE OF CONTENTS

DQR IDSubjectData Streams Affected
D111102.1GAN/RAIN/M1 - Incorrect precipitation dataganrainM1.b1
D120106.1GAN/RAIN/M1 - Precipitation not measuredganrainM1.b1
D120302.1GAN/RAIN/M1 - Noise in sensor 3ganrainM1.b1


DQRID : D111102.1
Start DateStart TimeEnd DateEnd Time
10/01/2011000010/14/20112359
10/21/2011000010/23/20112359
Subject:
GAN/RAIN/M1 - Incorrect precipitation data
DataStreams:ganrainM1.b1
Description:
The weighing bucket rain gauge was not reporting rainfall when other sensors were 
reporting rainfall, possibly due to configuration or connection problems.
Measurements:ganrainM1.b1:
  • error_latch
  • Precipitation rate(precip_rate)
  • weight3
  • total_mm
  • frequency3
  • frequency2
  • frequency1
  • stat_latch
  • total_weight
  • Precipitation, total(precip)
  • weight1
  • scans_per_min
  • temp3
  • weight2
  • ptemp
  • Model derived 2-meter temperature(temp2)
  • temp1


Back To Table of Contents

DQRID : D120106.1
Start DateStart TimeEnd DateEnd Time
11/27/2011092912/09/20112359
Subject:
GAN/RAIN/M1 - Precipitation not measured
DataStreams:ganrainM1.b1
Description:
After maintenance and emptying of the bucket, the data flat-lined at zero due to 
communications problems.
Measurements:ganrainM1.b1:
  • base_time
  • time_offset
  • volt_min
  • lon
  • Precipitation rate(precip_rate)
  • time
  • weight3
  • alt
  • frequency3
  • frequency2
  • frequency1
  • weight1
  • weight2
  • error_latch
  • lat
  • total_mm
  • stat_latch
  • total_weight
  • Precipitation, total(precip)
  • scans_per_min
  • ptemp
  • temp3
  • Model derived 2-meter temperature(temp2)
  • maintenance_cnt
  • temp1


Back To Table of Contents

DQRID : D120302.1
Start DateStart TimeEnd DateEnd Time
12/11/2011190012/12/20111230
Subject:
GAN/RAIN/M1 - Noise in sensor 3
DataStreams:ganrainM1.b1
Description:
Sensor 3 was noisy after data collection resumed.  This noise cleared up on its own by 
20111212 123000 and the noise will only effect the raw data.  The ingest which produces the 
b1 version of the data removes the noise.
Measurements:ganrainM1.b1:
  • frequency3
  • total_weight
  • Precipitation rate(precip_rate)
  • Precipitation, total(precip)
  • weight3


Back To Table of Contents



END OF DATA