DQR ID | Subject | Data Streams Affected |
---|---|---|
D110811.2 | PGH/MWRHF/M1 - Missing data | pghmwrhfM1.b1 |
D110927.1 | PGH/MWRHF/M1 - Reprocess: Incorrect calibration | pghmwrhfM1.b1 |
D110927.2 | PGH/MWRHF/M1 - Incorrect relative humidity readings | pghmwrhfM1.b1 |
D120724.1 | PGH/MWRHF/M1 - Rain flag intermittently working | pghmwrhfM1.b1 |
Start Date | Start Time | End Date | End Time |
---|---|---|---|
07/18/2011 | 0000 | 08/08/2011 | 0925 |
11/15/2011 | 0000 | 11/19/2011 | 0600 |
Subject: | PGH/MWRHF/M1 - Missing data |
DataStreams: | pghmwrhfM1.b1 |
Description: | Data are missing and unrecoverable. |
Measurements: | pghmwrhfM1.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
06/21/2011 | 0000 | 03/15/2012 | 2300 |
Subject: | PGH/MWRHF/M1 - Reprocess: Incorrect calibration |
DataStreams: | pghmwrhfM1.b1 |
Description: | The MWRHF is not tipping correctly. The views on the two sides of the radiometer are significantly different at all scanning angles. This could be an indication of obstructions in the field of view or a mirror misalignment. An LN2 calibration was unsuccessful as well. |
Measurements: | pghmwrhfM1.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
06/21/2011 | 0000 | 09/19/2011 | 0416 |
Subject: | PGH/MWRHF/M1 - Incorrect relative humidity readings |
DataStreams: | pghmwrhfM1.b1 |
Description: | The relative humidity readings are incorrect. |
Measurements: | pghmwrhfM1.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
06/20/2011 | 0000 | 03/31/2012 | 2300 |
Subject: | PGH/MWRHF/M1 - Rain flag intermittently working |
DataStreams: | pghmwrhfM1.b1 |
Description: | The rain flag didn't work consistently during the deployment. Users should check the rain flag from other instruments such as the MWR to screen for rain events/contamination. |
Measurements: | pghmwrhfM1.b1:
|