DQR ID | Subject | Data Streams Affected |
---|---|---|
D121004.1 | SGP/SIRS/E33 - Instrument noise problem | sgpsirs20sE33.a0, sgpsirsE33.b1 |
D121010.1 | SGP/SIRS/E33 - Instrument noise problem | sgpsirs20sE33.a0, sgpsirsE33.b1 |
Start Date | Start Time | End Date | End Time |
---|---|---|---|
02/01/2012 | 0000 | 08/14/2012 | 1559 |
08/14/2012 | 1600 | 09/26/2012 | 1839 |
Subject: | SGP/SIRS/E33 - Instrument noise problem |
DataStreams: | sgpsirs20sE33.a0, sgpsirsE33.b1 |
Description: | The UIR instrument (up_long_hemisp) had significant noise starting from the commission date. On 8/14/2012 15:59 site ops replaced the UIR which corrected the noise problem. However, the UIR calibration coefficient was incorrect until the datalogger program was updated on 9/26/2012 1839GMT. Data before 8/14 is not recoverable. Data after 8/14 will need to be reprocessed. Longwave UIR requires reprocessing from 8/14 to 9/26 using the 20second datastream and applying the following k1 coefficient: serial numbers are correct during this time. up_long_hemisp (old cal) = 0.2376 up_long_hemisp (corr cal) = 0.2451 |
Measurements: | sgpsirs20sE33.a0:
sgpsirsE33.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
08/14/2012 | 1615 | 08/17/2012 | 1816 |
08/17/2012 | 1817 | 09/26/2012 | 1839 |
Subject: | SGP/SIRS/E33 - Instrument noise problem |
DataStreams: | sgpsirs20sE33.a0, sgpsirsE33.b1 |
Description: | This DQR is an extension of D121004.1, the UIR instrument noise problem. It deals exclusively with the DIR (down_long_hemsip) datastream. It is filed separately due to the difficulty describing the problem in the space provided. During troublshooting of the UIR (up_long_hemisp) this instrument was swapped with the DIR (down_long_hemsip) to help isolate an instrument noise issue. After this swap it was determined that the noise was associated with a defective UIR instrument. For the first time range specified from 8/14 to 8/17 the DIR data is not recoverable since the instrument was faulty (it was the old bad UIR). the instrument was replaced on 8/17. For the second time range specified from 8/17 to 9/26 the DIR data had an incorrect calibration coefficienct applied until the logger program was updated on 9/26/2012 1839GMT. This data will require reprocessing. Longwave DIR (down_long_hemisp) requires reprocessing from 8/17 to 9/26 using the 20second datastream and applying the following k1 coefficient: serial number is correct during this time. up_long_hemisp (old cal) = 0.2967 up_long_hemisp (corr cal) = 0.3085 |
Measurements: | sgpsirs20sE33.a0:
sgpsirsE33.b1:
|