DQR ID | Subject | Data Streams Affected |
---|---|---|
D000608.7 | TWP/C2/SMET Wind Speeds | twpsmet60sC2.a1, twpsmet60sC2.b1, twpsmetC2.00 |
D000608.8 | TWP/C2/SMET Wind Speeds | twpsmet60sC2.a1, twpsmet60sC2.b1, twpsmetC2.00 |
D000608.9 | TWP/C2/SMET Winds Speeds | twpsmet60sC2.a1, twpsmet60sC2.b1, twpsmetC2.00 |
D000613.2 | TWP/C2/SMET Temperature spike | twpsmet60sC2.a1, twpsmet60sC2.b1 |
D000613.3 | TWP/C2/SMET - Pressure sensitivity to rain | twpsmet60sC2.a1, twpsmet60sC2.b1 |
D020109.2 | TWP/SMET/C2 - RH Sensor bad at Nauru | twpsmet60sC2.a1, twpsmet60sC2.b1 |
D020329.8 | TWP/SMET/C1/C2 - Switch to new Data Header Formats not timely | twpsmet60sC1.a1, twpsmet60sC1.b1, twpsmet60sC2.a1, twpsmet60sC2.b1 |
D020613.9 | TWP/C2 Installation | twpsmet60sC2.a1, twpsmet60sC2.b1, twpsmetC2.00 |
D030131.1 | TWP/SMET/C2 - Temperature Sensor Failed, Data Missing | twpsmet60sC2.a1, twpsmet60sC2.b1 |
D030501.5 | TWP/SMET/C2 - Upper wind sensor failed | twpsmet60sC2.b1 |
D040421.1 | TWP/SMET/C2 - Lower wind sensor failure | twpsmet60sC2.b1 |
D040722.7 | TWP/SMET/C2 - connection and timing issues with new logger | twpsmet60sC2.b1 |
D040726.1 | TWP/SMET/C2 - Negative rainfall rates | twpsmet60sC2.b1 |
D040824.2 | TWP/SMET/C2 - Incorrect rainrate equation used. | twpsmet60sC2.b1 |
D050301.1 | TWP/SMET/C2 - Upper wind direction sensor failure | twpsmet60sC2.b1 |
D050322.2 | TWP/SMET/C2 - Upper wind direction sensor failure | twpsmet60sC2.b1 |
D050714.1 | TWP/SMET/C2 - RH sensor failure | twpsmet60sC2.b1 |
D050920.4 | TWP/SMET/C2 - Instrument maintenance | twpsmet60sC2.b1 |
D050921.2 | TWP/SMET/C2 - ORG data incorrect | twpsmet60sC2.b1 |
D051005.6 | TWP/SMET/C2 - Tower down for calibration activities | twpsmet60sC2.b1 |
D060614.2 | TWP/SMET/C2 - Temp/RH probe failure | twpsmet60sC2.b1 |
D060818.2 | TWP/SMET/C2 - Reprocess: Barometric pressure units change | twpsmet60sC2.b1 |
D061011.3 | TWP/SMET/C2 - Reprocess: Tipping bucket rain gauge added | twpsmet60sC2.b1 |
D061214.2 | TWP/SMET/C2 - Barometer failure | twpsmet60sC2.b1 |
D070510.5 | TWP/SMET/C2 - Lower windspeed sensor questionable | twpsmet60sC2.b1 |
D070520.1 | TWP/SMET/C2 - Lower Wind Sensor Direction Incorrect | twpsmet60sC2.b1 |
D071219.1 | TWP/SMET/C2 - Lower Wind Speed Data Suspect | twpsmet60sC2.b1 |
D080428.4 | TWP/SMET/C2 - Reprocess: ORG Data has very small rainrate values | twpsmet60sC2.b1 |
D080617.1 | TWP/SMET/C2 - ORG rainfall measurements too large | twpsmet60sC2.b1 |
D080922.4 | TWP/SMET/C2 - Missing data | twpsmet60sC2.b1 |
D081022.5 | TWP/SMET/C2 - Wind Speed data contain offset due to induced voltage | twpsmet60sC2.b1 |
D081027.2 | TWP/SMET/C2 - ORG rainrate high due to calibration. | twpsmet60sC2.b1 |
D090604.2 | TWP/SMET/C2 - Barometer data incorrect | twpsmet60sC2.b1 |
D090918.1 | TWP/SMET/C2 - Induced wind speed when calm | twpsmet60sC2.b1 |
D091030.2 | TWP/SMET/C2 - Tower Lowered for Maintenance | twpsmet60sC2.b1 |
D100303.3 | TWP/SMET/C2 - Barometer failure | twpsmet60sC2.b1 |
Start Date | Start Time | End Date | End Time |
---|---|---|---|
12/24/1998 | 0000 | 01/08/1999 | 2100 |
Subject: | TWP/C2/SMET Wind Speeds |
DataStreams: | twpsmet60sC2.a1, twpsmet60sC2.b1, twpsmetC2.00 |
Description: | Beginning on December 24, Anemometer #1 (there are two anemometers on the SMET stand) occasionally reported wind speed values that were low relative to the other sensor. It is clear from the data that the low reading here is the anomalous one. |
Measurements: | twpsmet60sC2.b1:
twpsmetC2.00:
twpsmet60sC2.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
01/09/1999 | 2300 | 01/10/1999 | 0600 |
Subject: | TWP/C2/SMET Wind Speeds |
DataStreams: | twpsmet60sC2.a1, twpsmet60sC2.b1, twpsmetC2.00 |
Description: | Beginning on December 24, Anemometer #1 (there are two anemometers on the SMET stand) occasionally reported wind speed values that were low relative to the other sensor. It is clear from the data that the low reading here is the anomalous one. |
Measurements: | twpsmet60sC2.b1:
twpsmetC2.00:
twpsmet60sC2.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
01/14/1999 | 1430 | 01/14/1999 | 2100 |
Subject: | TWP/C2/SMET Winds Speeds |
DataStreams: | twpsmet60sC2.a1, twpsmet60sC2.b1, twpsmetC2.00 |
Description: | Beginning on December 24, Anemometer #1 (there are two anemometers on the SMET stand) occasionally reported wind speed values that were low relative to the other sensor. It is clear from the data that the low reading here is the anomalous one. |
Measurements: | twpsmet60sC2.b1:
twpsmetC2.00:
twpsmet60sC2.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
12/03/1998 | 2105 | 12/03/1999 | 2105 |
Subject: | TWP/C2/SMET Temperature spike |
DataStreams: | twpsmet60sC2.a1, twpsmet60sC2.b1 |
Description: | There was a brief -4 C spike in the temperature at approximately 21.5 Z on December 3. This spike also showed up in the vapor pressure which is calculated from the temperature and relative humidity. |
Measurements: | twpsmet60sC2.b1:
twpsmet60sC2.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
11/20/1998 | 0000 | 12/31/1998 | 2359 |
Subject: | TWP/C2/SMET - Pressure sensitivity to rain |
DataStreams: | twpsmet60sC2.a1, twpsmet60sC2.b1 |
Description: | The pressure behaves anomalously during rain events - even very mild ones. Normally, the pressure undergoes a smooth semi-diurnal oscillation with little higher frequency variability. However, during and shortly after rain events, the pressure signal exhibits abrupt changes - this sort of behavior has occasionally been observed at Manus but not with the regularity seen here. Examples of this behaviour occur on (date in the form YYYYMMDD): 19981212 19981215 19981216 19981217 19981223 19981224 19981225 19981230 19981231 |
Measurements: | twpsmet60sC2.b1:
twpsmet60sC2.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
12/16/2001 | 0300 | 01/03/2002 | 0841 |
Subject: | TWP/SMET/C2 - RH Sensor bad at Nauru |
DataStreams: | twpsmet60sC2.a1, twpsmet60sC2.b1 |
Description: | RH sensor bad from 16 Dec 2001 03 GMT to 3 Jan 2002 |
Measurements: | twpsmet60sC2.b1:
twpsmet60sC2.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
03/31/2001 | 2359 | 04/01/2001 | 0020 |
Subject: | TWP/SMET/C1/C2 - Switch to new Data Header Formats not timely |
DataStreams: | twpsmet60sC1.a1, twpsmet60sC1.b1, twpsmet60sC2.a1, twpsmet60sC2.b1 |
Description: | On April 1, 2001 at 00:00:00 new data header with consistent variable naming conventions, etc were to be used for all sites, all data streams. At the TWP sites the time of the movement to the new convention did not occur precisely at 00:00:00. The following data files contain between 40 seconds and 20 minutes of data from 4/1/02 in the old format. The delayed format change did not affect data quality in any way. twpsmet60sC1.a1.20010401.000001.cdf twpsmet60sC1.b1.20010401.000001.cdf twpsmet60sC2.a1.20010401.000000.cdf twpsmet60sC2.b1.20010401.000000.cdf |
Measurements: | twpsmet60sC2.b1:
twpsmet60sC1.b1:
twpsmet60sC1.a1:
twpsmet60sC2.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/21/1998 | 0312 | 11/19/1998 | 2359 |
Subject: | TWP/C2 Installation |
DataStreams: | twpsmet60sC2.a1, twpsmet60sC2.b1, twpsmetC2.00 |
Description: | The Nauru ARCS was installed during the period September-November 1998. Data were being collected by the end of October, but for the first several weeks of November, the site was undergoing considerable change, so data from that period should be used with caution. The official site dedication occured on November 20. Most on-site activity ended following the dedication so we will consider November 20 to be the beginning of the Nauru operations. The last members of the installation team left Nauru on November 24. |
Measurements: | twpsmet60sC2.b1:
twpsmetC2.00:
twpsmet60sC2.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
01/24/2003 | 0100 | 01/30/2003 | 0500 |
Subject: | TWP/SMET/C2 - Temperature Sensor Failed, Data Missing |
DataStreams: | twpsmet60sC2.a1, twpsmet60sC2.b1 |
Description: | The T/RH sensor on Nauru failed and was replaced (only the temperature sensor failed). |
Measurements: | twpsmet60sC2.b1:
twpsmet60sC2.a1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
04/12/2003 | 1000 | 04/24/2003 | 0020 |
Subject: | TWP/SMET/C2 - Upper wind sensor failed |
DataStreams: | twpsmet60sC2.b1 |
Description: | The upper wind speed sensor failed. Wind speeds were reported as 0 m/s and wind direction data was not in agreement with the lower wind sensor. Anemometer was replaced. |
Measurements: | twpsmet60sC2.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
04/10/2004 | 0000 | 04/24/2004 | 2303 |
Subject: | TWP/SMET/C2 - Lower wind sensor failure |
DataStreams: | twpsmet60sC2.b1 |
Description: | The lower wind sensor failed. Wind direction showed little or no variation, unlike the co-located/upper sensor. This caused depressed wind speed values as the sensor was not rotating properly to orient itself parallel to the wind stream. The sensor was replaced. |
Measurements: | twpsmet60sC2.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
07/07/2004 | 0138 | 07/07/2004 | 2018 |
Subject: | TWP/SMET/C2 - connection and timing issues with new logger |
DataStreams: | twpsmet60sC2.b1 |
Description: | Atmospheric pressure data are intermittent during this time period due to connection problems and program timing issues with new logger installation. Data resumed normal operations after this time period. |
Measurements: | twpsmet60sC2.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/21/1998 | 0311 | 07/06/2004 | 0138 |
Subject: | TWP/SMET/C2 - Negative rainfall rates |
DataStreams: | twpsmet60sC2.b1 |
Description: | Due to limitations of the Zeno dataloggers all voltage measurements from the optical rain gauge (ORG) were converted to rainfall rates. This resulted in negative values for rain rates. Any value below 0.10 mm/hr should be considered to be 0 mm/hr. New dataloggers alleviated this problem. |
Measurements: | twpsmet60sC2.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
07/07/2004 | 0137 | 08/17/2004 | 2157 |
Subject: | TWP/SMET/C2 - Incorrect rainrate equation used. |
DataStreams: | twpsmet60sC2.b1 |
Description: | There are two different Optical Raingages in use at the TWP sites. The incorrect equation was used at this site. The incorrect equation is (25*(V^1.87)) - 0.15. The correct equation is (20*(V^2)) - 0.05. The correct equation was installed. |
Measurements: | twpsmet60sC2.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
02/12/2005 | 1955 | 03/03/2005 | 0430 |
Subject: | TWP/SMET/C2 - Upper wind direction sensor failure |
DataStreams: | twpsmet60sC2.b1 |
Description: | The upper wind direction sensor failed. Wind direction was reported at a near constant value of 69 degrees and was significantly different than the lower wind sensor's direction values. Sensor replaced. |
Measurements: | twpsmet60sC2.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
03/09/2005 | 2300 | 04/17/2005 | 0332 |
Subject: | TWP/SMET/C2 - Upper wind direction sensor failure |
DataStreams: | twpsmet60sC2.b1 |
Description: | After replacement on 03/03/2005 the upper wind direction sensor began reporting erroneous values again on 03/09/2005 becoming very apparent after 03/17/2005. Wind speed data appears reasonable but the wind direction data do not agree well with the lower wind sensor. |
Measurements: | twpsmet60sC2.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
07/10/2005 | 1900 | 07/14/2005 | 2226 |
Subject: | TWP/SMET/C2 - RH sensor failure |
DataStreams: | twpsmet60sC2.b1 |
Description: | Relative humidity values were frequently over MAX value of 104% starting on 7/10/2005 through end of period. Sensor was replaced. |
Measurements: | twpsmet60sC2.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
09/21/2005 | 1625 | 09/21/2005 | 1815 |
Subject: | TWP/SMET/C2 - Instrument maintenance |
DataStreams: | twpsmet60sC2.b1 |
Description: | Instrument calibration and testing were taking place for brief periods. |
Measurements: | twpsmet60sC2.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
09/19/2005 | 0809 | 09/19/2005 | 1902 |
Subject: | TWP/SMET/C2 - ORG data incorrect |
DataStreams: | twpsmet60sC2.b1 |
Description: | Data from the ORG was incorrect due to heavy condensation on the lens. |
Measurements: | twpsmet60sC2.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
09/19/2005 | 0200 | 09/19/2005 | 0330 |
Subject: | TWP/SMET/C2 - Tower down for calibration activities |
DataStreams: | twpsmet60sC2.b1 |
Description: | Tower lowered, wind vanes spun at different frequencies, and ORG tested with electronic rain. |
Measurements: | twpsmet60sC2.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
06/05/2006 | 2144 | 06/15/2006 | 0427 |
Subject: | TWP/SMET/C2 - Temp/RH probe failure |
DataStreams: | twpsmet60sC2.b1 |
Description: | Temperature/RH probe failed and was replaced. |
Measurements: | twpsmet60sC2.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/21/1998 | 0000 | 07/06/2004 | 2359 |
Subject: | TWP/SMET/C2 - Reprocess: Barometric pressure units change |
DataStreams: | twpsmet60sC2.b1 |
Description: | Barometric pressure data during this time period is reported in hPa. After this time, the data have been converted to kPa to standardize the measurement units among ARM sites and to conform to accepted standard units determined by the scientific community. |
Measurements: | twpsmet60sC2.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/21/1998 | 0000 | 11/29/2006 | 2014 |
Subject: | TWP/SMET/C2 - Reprocess: Tipping bucket rain gauge added |
DataStreams: | twpsmet60sC2.b1 |
Description: | A tipping bucket rain gauge was added to the TWP.C2 SMET suite of instruments on 20061129. Effective 20060926, two new variables (count and rain amount) were added to the end of the twpsmet60sC2.b1 datastream. Between 9/26 and 11/29, the data for these two variables are filled with zeros. Users should not use the data during this period as the zeros are not representative of the rain fall at the site. When reprocessing of this datastream occurs these variables will be added for the 19981021-20060926 and data from 19981021-20061129 will be filled with -9999 (missing). |
Measurements: | twpsmet60sC2.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
12/07/2006 | 1941 | 01/23/2007 | 0023 |
Subject: | TWP/SMET/C2 - Barometer failure |
DataStreams: | twpsmet60sC2.b1 |
Description: | The barometer began experiencing problems with noise resulting in incorrect data. The problem becames worse over time; after 12/19/2006 @0151 GMT the barometer data is completely missing. The barometer was replaced. |
Measurements: | twpsmet60sC2.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
04/05/2007 | 0000 | 08/19/2007 | 2135 |
Subject: | TWP/SMET/C2 - Lower windspeed sensor questionable |
DataStreams: | twpsmet60sC2.b1 |
Description: | Lower wind speed sensor had degraded bearings. This sensor was reporting as much as 0.4 m/s lower values than the upper sensors when the winds were 2 m/s or below. The sensor was replaced. |
Measurements: | twpsmet60sC2.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
05/11/2007 | 0000 | 05/22/2007 | 0047 |
Subject: | TWP/SMET/C2 - Lower Wind Sensor Direction Incorrect |
DataStreams: | twpsmet60sC2.b1 |
Description: | Wind directions between lower and upper anemometers were displaced by approximately 45 degrees when a new sensor was installed to replace the failing lower winde sensor. The new sensor direction data incorrect. |
Measurements: | twpsmet60sC2.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
05/22/2007 | 0048 | 08/19/2007 | 2150 |
Subject: | TWP/SMET/C2 - Lower Wind Speed Data Suspect |
DataStreams: | twpsmet60sC2.b1 |
Description: | The lower wind speed bearings appeared to be binding at speeds below 2 m/s as it did not compare well with the upper wind sensor. |
Measurements: | twpsmet60sC2.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
07/01/2004 | 0000 | 06/30/2010 | 2359 |
Subject: | TWP/SMET/C2 - Reprocess: ORG Data has very small rainrate values |
DataStreams: | twpsmet60sC2.b1 |
Description: | The ORG data is collected via analog signal and not digital. Therefore, we continuously collect data even when no rain is occurring. We also capture small events such as leaves, large bugs, dust, etc blowing through the measurement path. Because this discrete event occurs quickly the value is usually captured for 1 or 2 seconds. This value is then averaged to the minute producing rainrate on the order of .009 mm/hr or less. These values are not indicative of rain and should be removed from the record or summing over long periods can bias the climate record. We will reprocess the data to remove these small values. |
Measurements: | twpsmet60sC2.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
05/08/2008 | 0000 | 08/07/2008 | 2300 |
Subject: | TWP/SMET/C2 - ORG rainfall measurements too large |
DataStreams: | twpsmet60sC2.b1 |
Description: | The ORG was collecting large amounts of rainfall compared to the co-located tipping bucket raingauge. The cable was chewed by mice causing the wires to make contact intermittently mimicking rainfall. |
Measurements: | twpsmet60sC2.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
06/28/2000 | 1103 | 07/06/2000 | 0432 |
Subject: | TWP/SMET/C2 - Missing data |
DataStreams: | twpsmet60sC2.b1 |
Description: | Data are missing and unrecoverable. |
Measurements: | twpsmet60sC2.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
11/01/1998 | 0000 | 02/23/2009 | 0410 |
Subject: | TWP/SMET/C2 - Wind Speed data contain offset due to induced voltage |
DataStreams: | twpsmet60sC2.b1 |
Description: | The marine model of the RM Young wind sensor needs twisted pair shielded cable. The manufacturer did not originally supply the pigtail with twisted pair shielded cable. Use of twisted pair shielded cable for the rest of the cable run to the logger was also not specified. This caused an induced voltage in the wind speed line from the wind direction excitation. The induced voltage varied from sensor to sensor and probably changed anytime the cable was replaced or parts of the wind sensor were repaired or replaced. The induced voltage has been seen to vary from 0.15 m/s to as much as 1.08 m/s. |
Measurements: | twpsmet60sC2.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/05/2008 | 2311 | 10/05/2008 | 2344 |
Subject: | TWP/SMET/C2 - ORG rainrate high due to calibration. |
DataStreams: | twpsmet60sC2.b1 |
Description: | The rainrate from the ORG was high due to calibration. This data is not real. |
Measurements: | twpsmet60sC2.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
05/20/2009 | 0004 | 06/05/2009 | 2359 |
Subject: | TWP/SMET/C2 - Barometer data incorrect |
DataStreams: | twpsmet60sC2.b1 |
Description: | Beginning 05/20, atmos_pressure exceeded MAX between ~21:00 and 01:00 UTC on most days. The inlet tube was accidentally pinched in the door of the logger enclosure artificially increasing the atmospheric pressure during the listed times. Only a few hours exceeded max limits. |
Measurements: | twpsmet60sC2.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
07/01/2009 | 0100 | 10/15/2009 | 0300 |
Subject: | TWP/SMET/C2 - Induced wind speed when calm |
DataStreams: | twpsmet60sC2.b1 |
Description: | The upper and lower wind sensors were not trending well at wind speed below 1 m/s. Both sensors were showing values above 0m/s when calm. The lightning protector was at fault resulting in an induced wind voltage during calm conditions. Users should subtract any offset found (for example 0.19 m/s for upper wind speed) when the wind speeds are flat-lined. The offset value was not consistent. |
Measurements: | twpsmet60sC2.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/14/2009 | 2150 | 10/15/2009 | 0315 |
Subject: | TWP/SMET/C2 - Tower Lowered for Maintenance |
DataStreams: | twpsmet60sC2.b1 |
Description: | Data is suspect due to the tower being lowered. |
Measurements: | twpsmet60sC2.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
02/04/2010 | 0600 | 02/23/2010 | 2315 |
Subject: | TWP/SMET/C2 - Barometer failure |
DataStreams: | twpsmet60sC2.b1 |
Description: | The atmos_pressure values were spiking high (up to 110 kPa) from 06:00 UTC on 02/04 until the data went missing at 10:44 UTC on 02/06 when the barometer failed completely. Barometer replaced 2/23. |
Measurements: | twpsmet60sC2.b1:
|