Data Quality Reports for Session: 146308 User: vmanoharan Completed: 11/30/2012


TABLE OF CONTENTS

DQR IDSubjectData Streams Affected
D111006.3PGH/TSI/M1 - Ingest ProblempghtsiskycoverM1.b1
D121029.1PGH/SKYRAD/M1 - Reprocess: Incorrect calibrationspghskyrad20sM1.a0, pghskyrad60sM1.b1
D121029.2PGH/GNDRAD/M1 - Reprocess: Incorrect calibrationspghgndrad20sM1.a0, pghgndrad60sM1.b1


DQRID : D111006.3
Start DateStart TimeEnd DateEnd Time
11/11/2010165010/20/20111204
Subject:
PGH/TSI/M1 - Ingest Problem
DataStreams:pghtsiskycoverM1.b1
Description:
A minor error was made with diagnostic metadata attribute sunny_thresh when the TSI ingest 
was updated.
Measurements:pghtsiskycoverM1.b1:
  • base_time


Back To Table of Contents

DQRID : D121029.1
Start DateStart TimeEnd DateEnd Time
06/04/2011050903/31/20122359
Subject:
PGH/SKYRAD/M1 - Reprocess: Incorrect calibrations
DataStreams:pghskyrad20sM1.a0, pghskyrad60sM1.b1
Description:
During the entire India deployment the Skyrad system was configured with incorrect 
calibration coefficients for the shortwave instruments. The program hadn't been updated since 
the previous deployment in the Azores.

The instrument mentor, site personal and OSS support have attempted to best determine the 
serial numbers of instruments installed at PGH during the deployment period.  The 
following instrument data will need to be reprocessed with the following correction multipliers:

PIR1-DIR(down_long_hemisp1): OK, no correction required
PIR2-DIR(down_long_hemisp2): OK, no correction required
Diffuse 8-48 (down_short_diffuse): 116.95(correct)/120.91(incorrect) = .96725
NIP (short_direct_normal): 127.03(correct)/124.97(incorrect) = 1.01648
PSP-DS (down_short_hemsip): 111.29(correct)/108.48(incorrect) = 1.02590
IRT: calibration should be validated by instrument mentor (Vic Morris): mult=26, 
offset=173.2

Correct serial numbers:   
Diffuse 8-48 (down_short_diffuse): 34066
NIP (short_direct_normal): 34135E6
PSP-DS (down_short_hemsip): 33942F3
Measurements:pghskyrad20sM1.a0:
  • inst_global
  • inst_diffuse
  • inst_sky_ir_signal
  • inst_direct_normal

pghskyrad60sM1.b1:
  • Downwelling Shortwave Diffuse Hemisp. Irrad., Ventilated Pyranometer, Minima(down_short_diffuse_hemisp_min)
  • Radiation, shortwave, downwelling total hemispheric irradiance, 1-min avg(down_short_hemisp)
  • Downwelling Shortwave Hemispheric Irradiance, Ventilated Pyranometer, Minima(down_short_hemisp_min)
  • down_short_hemisp_std
  • IR Brightness Temperature(sky_ir_temp)
  • Downwelling Shortwave Hemispheric Irradiance, Ventilated Pyranometer, Maxima(down_short_hemisp_max)
  • sky_ir_temp_min
  • Radiation, shortwave, downwelling diffuse hemispheric irradiance, 1-min avg(down_short_diffuse_hemisp)
  • Shortwave Direct Normal Irradiance, Pyrheliometer, Maxima(short_direct_normal_max)
  • sky_ir_temp_max
  • Downwelling Shortwave Diffuse Hemisp. Irrad., Ventilated Pyranometer, Maxima(down_short_diffuse_hemisp_max)
  • sky_ir_temp_std
  • Radiation, shortwave, direct normal irradiance, 1-min avg(short_direct_normal)
  • down_short_diffuse_hemisp_std
  • Shortwave Direct Normal Irradiance, Pyrheliometer, Minima(short_direct_normal_min)
  • short_direct_normal_std


Back To Table of Contents

DQRID : D121029.2
Start DateStart TimeEnd DateEnd Time
06/09/2011103303/31/20122359
Subject:
PGH/GNDRAD/M1 - Reprocess: Incorrect calibrations
DataStreams:pghgndrad20sM1.a0, pghgndrad60sM1.b1
Description:
During the entire India deployment the Gndrad system was configured with incorrect 
calibration coefficients for the shortwave instruments. The program hadn't been updated since 
the previous deployment in the Azores.

The instrument mentor, site personal and OSS support have attempted to best determine the 
serial numbers of instruments installed at PGH during the deployment period.  The 
following instrument data will need to be reprocessed with the following correction multipliers:
PIR-UIR(up_long_hemisp): OK, no correction required
PSP-US (up_short_hemsip): 117.97(correct)/129.42(incorrect) = 0.91153
IRT: calibration should be validated by instrument mentor (Vic Morris): mult=25, 
offset=223.2

Correct serial numbers:
PSP-US (up_short_hemsip): 33941F3
Measurements:pghgndrad20sM1.a0:
  • inst_up_short_hemisp
  • inst_sfc_ir_signal

pghgndrad60sM1.b1:
  • Effective Surface (Skin) Temperature(sfc_ir_temp)
  • sfc_ir_temp_std
  • Surface Infra-Red Temperature Minima(sfc_ir_temp_min)
  • Radiation, shortwave, at 10-m height, upwelling hemispheric irrad., 1-min avg(up_short_hemisp)
  • Upwelling Shortwave Hemispheric Irradiance, Unventilated Pyranometer, Maxima(up_short_hemisp_max)
  • Upwelling Shortwave Hemispheric Irradiance, Unventilated Pyranometer, Minima(up_short_hemisp_min)
  • up_short_hemisp_std
  • Surface Infra-Red Temperature Maxima(sfc_ir_temp_max)


Back To Table of Contents



END OF DATA