DQR ID | Subject | Data Streams Affected |
---|---|---|
D040127.2 | SGP/SONDE/C1 - Bad RH Data | sgpsondewnpnC1.b1 |
D040219.1 | SGP/SONDE/C1 - Bad RH Data | sgpsondewnpnC1.b1 |
D040219.2 | SGP/SONDE/C1 - Surface pressure incorrect | sgpsondewnpnC1.b1 |
D040223.1 | SGP/SONDE/C1 - Broken temperature sensor | sgpsondewnpnC1.b1 |
D040301.1 | SGP/SONDE/C1 - Broken temperature sensor | sgpsondewnpnC1.b1 |
D040415.2 | SGP/SONDE/C1 - Temperature sensor broke high into the sounding | sgpsondewnpnC1.b1 |
D041005.1 | SGP/SONDE/C1 - Incorrect surface temperature | sgpsondewnpnC1.b1 |
D041013.4 | SGP/SONDE/C1 - Scheduled Soundings Missed | sgpsondeC1.00, sgpsondewnpnC1.b1 |
D060303.1 | SGP/SONDE/C1 - DigiCORAIII failed, replaced with S01/S02 launches | sgpsondeC1.00, sgpsondewnpnC1.b1 |
D060928.3 | SGP/SONDE/C1 - Increased precision for alt, dp, pres, rh, tdry | sgpsondewnpnC1.b1 |
Start Date | Start Time | End Date | End Time |
---|---|---|---|
01/16/2004 | 2015 | 01/16/2004 | 2151 |
Subject: | SGP/SONDE/C1 - Bad RH Data |
DataStreams: | sgpsondewnpnC1.b1 |
Description: | The RH values during the first half of this sounding oscillate between reasonable values and near-zero values. The oscillation is irregular and seems to be related to failure of the RH sensor heating process. |
Measurements: | sgpsondewnpnC1.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
02/09/2004 | 0530 | 02/09/2004 | 0601 |
Subject: | SGP/SONDE/C1 - Bad RH Data |
DataStreams: | sgpsondewnpnC1.b1 |
Description: | The RH values during the first part of this sounding oscillate between reasonable values and near-zero values. The oscillation seems to be related to failure of the RH sensor heating process. |
Measurements: | sgpsondewnpnC1.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
02/02/2004 | 0530 | 02/02/2004 | 0826 |
Subject: | SGP/SONDE/C1 - Surface pressure incorrect |
DataStreams: | sgpsondewnpnC1.b1 |
Description: | I think the operator inadvdertently transposed to digits when entering the surface pressure value. The value entered is 987.0 hPa but the value shown in the raw data file at launch is 978.0. As a result, the absolute altitudes in this sounding will be slightly incorrect as will be the ascent rate during the first 30 seconds of flight. |
Measurements: | sgpsondewnpnC1.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
02/19/2004 | 1746 | 02/19/2004 | 1946 |
Subject: | SGP/SONDE/C1 - Broken temperature sensor |
DataStreams: | sgpsondewnpnC1.b1 |
Description: | The temperature sensor broke at launch on this sounding. All of the temperature-related data (tdry, rh, dp) are incorrect. |
Measurements: | sgpsondewnpnC1.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
02/27/2004 | 0531 | 02/27/2004 | 0721 |
Subject: | SGP/SONDE/C1 - Broken temperature sensor |
DataStreams: | sgpsondewnpnC1.b1 |
Description: | The temperature sensor broke shortly after launch on this sounding. All of the temperature-related data (tdry, rh, dp) are incorrect. |
Measurements: | sgpsondewnpnC1.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
04/13/2004 | 1229 | 04/13/2004 | 1301 |
Subject: | SGP/SONDE/C1 - Temperature sensor broke high into the sounding |
DataStreams: | sgpsondewnpnC1.b1 |
Description: | The temperature sensor on this radiosonde appeared to break 56 minutes and 22 seconds into the sounding at an altitude of 16570 m. All the data below this point are good; only the data above this point to the end of the sounding (88 minutes and 14 seconds) are bad. |
Measurements: | sgpsondewnpnC1.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/02/2004 | 1130 | 10/02/2004 | 1131 |
Subject: | SGP/SONDE/C1 - Incorrect surface temperature |
DataStreams: | sgpsondewnpnC1.b1 |
Description: | The operator entered a the surface temperature incorrectly on this sounding. The sonde data file shows the temperature as 33.5 degC but the operations log shows it as 3.5 degC. The first temperature recorded by the sonde after launch is 3.7 degC, consistent with the typical early morning inversion. |
Measurements: | sgpsondewnpnC1.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
01/16/2004 | 2330 | 01/17/2004 | 1830 |
01/18/2004 | 0530 | 01/18/2004 | 0630 |
01/21/2004 | 0530 | 01/21/2004 | 0630 |
Subject: | SGP/SONDE/C1 - Scheduled Soundings Missed |
DataStreams: | sgpsondeC1.00, sgpsondewnpnC1.b1 |
Description: | The following scheduled sonde launches were missed due to computer system failures: 20040116.2330 20040117.0530 20040117.1130 20040117.1730 20040118.0530 20040121.0530 |
Measurements: | sgpsondeC1.00:
sgpsondewnpnC1.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
01/17/2004 | 2331 | 01/18/2004 | 0108 |
01/18/2004 | 1138 | 01/18/2004 | 1252 |
01/18/2004 | 1729 | 01/18/2004 | 1852 |
01/18/2004 | 2339 | 01/19/2004 | 0111 |
01/19/2004 | 0531 | 01/19/2004 | 0711 |
01/19/2004 | 1136 | 01/19/2004 | 1316 |
01/19/2004 | 2331 | 01/20/2004 | 0101 |
01/19/2004 | 1723 | 01/19/2004 | 1752 |
01/20/2004 | 0531 | 01/20/2004 | 0703 |
01/20/2004 | 1132 | 01/20/2004 | 1332 |
01/20/2004 | 1728 | 01/20/2004 | 1928 |
01/20/2004 | 2330 | 01/21/2004 | 0130 |
01/21/2004 | 1731 | 01/21/2004 | 1931 |
Subject: | SGP/SONDE/C1 - DigiCORAIII failed, replaced with S01/S02 launches |
DataStreams: | sgpsondeC1.00, sgpsondewnpnC1.b1 |
Description: | The digiCORA-III failed on Saturday 2004-01-17. The operators reported that they were unable to load the software and conduct normal soundings. Following procedure, they conducted the regular soundings by using the S01/S02 systems as allowed by the AIRS IOP schedule. The netCDF header fields "input_source" and "facility_id" will mention which of the S01/S02 systems was used in these launches. |
Measurements: | sgpsondeC1.00:
sgpsondewnpnC1.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
09/28/2006 | 1728 | 12/31/9999 | 2359 |
Subject: | SGP/SONDE/C1 - Increased precision for alt, dp, pres, rh, tdry |
DataStreams: | sgpsondewnpnC1.b1 |
Description: | The output precision of the following variables was increased 20060928 alt changed from 1m to 0.1m dp changed from 0.1degC to 0.01degC pres changed from 0.1 hPa to 0.01 hPa RH changed from 1%RH to 0.01%RH tdry changed from .1degC to 0.01degC Note that the increase in precision does not necessarily imply an increase in accuracy. Users are cautioned to continue to use their best scientific judgement when using these or any other data. |
Measurements: | sgpsondewnpnC1.b1:
|