DQR ID | Subject | Data Streams Affected |
---|---|---|
D021211.1 | TWP/SMET/C3 - Lower wind direction sensor misaligned | twpsmet60sC3.a1, twpsmet60sC3.b1 |
D030212.1 | TWP/SMET/C3 - Intermittent Pressure Sensor Failure | twpsmet60sC3.a1, twpsmet60sC3.b1 |
D031103.2 | TWP/SMET/C3 - Data reported at 15sec rather than 60s intervals | twpsmet60sC3.a1, twpsmet60sC3.b1 |
D040722.4 | TWP/SMET/C3 - Rain blocked pressure port | twpsmet60sC3.b1 |
D040726.3 | TWP/SMET/C3 - Negative rainfall rates | twpsmet60sC3.b1 |
D050210.1 | TWP/SMET/C3 - Data non-representative | twpsmet60sC3.b1 |
D050418.2 | TWP/SMET/C3 - Lower wind direction sensor failure | twpsmet60sC3.b1 |
D050808.3 | TWP/SMET/C3 - Data not representative | twpsmet60sC3.b1 |
D051115.1 | TWP/SMET/C3 - Upper wind sensor failure | twpsmet60sC3.b1 |
D051117.2 | TWP/SMET/C3 - RH Values Artificially High | twpsmet60sC3.b1 |
D051117.3 | TWP/SMET/C3 - Instrument failure | twpsmet60sC3.b1 |
D060426.8 | TWP/SMET/C3 - ORG data noisy due to degraded ground | twpsmet60sC3.b1 |
D060502.3 | TWP/SMET/C3 - Reprocessed: Lower windspeed sensor calibration error | twpsmet60sC3.b1 |
D060627.1 | TWP/SMET/C3 - Data not representative | twpsmet60sC3.b1 |
D061011.4 | TWP/SMET/C3 - Reprocess: Tipping bucket rain gauge added | twpsmet60sC3.b1 |
D070306.2 | TWP/SMET/C3 - Barometer Data Incorrect | twpsmet60sC3.b1 |
D070306.3 | TWP/SMET/C3 - Water in enclosure | twpsmet60sC3.b1 |
D070803.1 | TWP/SMET/C3 - Upper wind speed artificially slow | twpsmet60sC3.b1 |
D071105.1 | TWP/SMET/C3 - ORG overestimated rainfall | twpsmet60sC3.b1 |
D080225.1 | TWP/SMET/C3 - Upper Wind Sensor Data Questionable | twpsmet60sC3.b1 |
D080428.3 | TWP/SMET/C3 - Reprocess: ORG Data has very small rainrate values | twpsmet60sC3.b1 |
D080611.2 | TWP/SMET/C3 - Lower Wind Direction Intermittently Wrong | twpsmet60sC3.b1 |
D080715.1 | TWP/SMET/C3 - Upper wind speed data incorrect | twpsmet60sC3.b1 |
D080922.5 | TWP/SMET/C3 - Missing data | twpsmet60sC3.b1 |
D081022.8 | TWP/SMET/C3 - Wind Speed data contain offset due to induced voltage | twpsmet60sC3.b1 |
D090129.4 | TWP/SMET/C3 - Reprocess: Station Pressure values reported in hPa instead of kPa. | twpsmet60sC3.b1 |
D090225.3 | TWP/SMET/C3 - Reprocess: Temperature data biased low | twpsmet60sC3.b1 |
D090515.1 | TWP/SMET/C3 - Reprocess: Temperature Biased low by 1.06 Degrees | twpsmet60sC3.b1 |
D091023.1 | TWP/SMET/C3 - Tower Lowered for Maintenance | twpsmet60sC3.b1 |
Start Date | Start Time | End Date | End Time |
---|---|---|---|
08/21/2002 | 0000 | 12/09/2002 | 0000 |
Subject: | TWP/SMET/C3 - Lower wind direction sensor misaligned |
DataStreams: | twpsmet60sC3.a1, twpsmet60sC3.b1 |
Description: | The lower wind direction sensor (sensor #2) was misaligned and off by 15 degrees. |
Measurements: | twpsmet60sC3.a1:
twpsmet60sC3.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
10/23/2002 | 0000 | 02/06/2003 | 2203 |
Subject: | TWP/SMET/C3 - Intermittent Pressure Sensor Failure |
DataStreams: | twpsmet60sC3.a1, twpsmet60sC3.b1 |
Description: | The Barometric Pressure sensor was intermittently failing at TWP site C3 Darwin. At times there were large pressure fluctuations occurring on the order of 24 mb in a few minutes. Times of large pressure fluctuations are readily apparent in the data. At these times the data should be carefully analyzed before determining it's usefulness. In between the periods of large fluctuations the readings appear to be stable. It is still suggested that independent pressure data be obtained for comparison before use. |
Measurements: | twpsmet60sC3.a1:
twpsmet60sC3.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
03/12/2002 | 0628 | 06/03/2002 | 2359 |
Subject: | TWP/SMET/C3 - Data reported at 15sec rather than 60s intervals |
DataStreams: | twpsmet60sC3.a1, twpsmet60sC3.b1 |
Description: | Data in these data streams should be reported at 60sec intervals, but the logger program running during this time had the interval set to 15s. Users will have to average the 15sec data to get 60sec data. |
Measurements: | twpsmet60sC3.a1:
twpsmet60sC3.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
01/01/2004 | 0000 | 05/17/2004 | 2259 |
Subject: | TWP/SMET/C3 - Rain blocked pressure port |
DataStreams: | twpsmet60sC3.b1 |
Description: | Atmospheric pressure values were suspect due to anomolous readings during heavy rain events. Suspect blockage of port due to rainfall. New logger and enclosure corrected problem. |
Measurements: | twpsmet60sC3.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
03/12/2002 | 0628 | 05/17/2004 | 2300 |
Subject: | TWP/SMET/C3 - Negative rainfall rates |
DataStreams: | twpsmet60sC3.b1 |
Description: | Due to limitations of the Zeno dataloggers all voltage measurements from the optical rain gauge (ORG) were converted to rainfall rates. This resulted in negative values for rain rates. Any value below 0.10 mm/hr should be considered to be 0 mm/hr. New dataloggers alleviated this problem. |
Measurements: | twpsmet60sC3.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
02/09/2005 | 2310 | 02/09/2005 | 2320 |
Subject: | TWP/SMET/C3 - Data non-representative |
DataStreams: | twpsmet60sC3.b1 |
Description: | Tower mast was lowered for inspection. Data during this time is non-representative. |
Measurements: | twpsmet60sC3.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
04/14/2005 | 0230 | 04/19/2005 | 0050 |
Subject: | TWP/SMET/C3 - Lower wind direction sensor failure |
DataStreams: | twpsmet60sC3.b1 |
Description: | The lower wind direction sensor failed on 4/14 and disagrees significantly with the upper wind direction sensor. The lower wind sensor reports a constant value around 0-15 degrees since it failed. Testing showed that excitation channel two on the logger was the problem. Logger was replaced by spare. |
Measurements: | twpsmet60sC3.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
08/05/2005 | 0030 | 08/05/2005 | 0330 |
Subject: | TWP/SMET/C3 - Data not representative |
DataStreams: | twpsmet60sC3.b1 |
Description: | Tower was lowered for radiometer change and characterization. Data are not representative of local conditions. |
Measurements: | twpsmet60sC3.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
11/14/2005 | 0453 | 11/15/2005 | 2215 |
Subject: | TWP/SMET/C3 - Upper wind sensor failure |
DataStreams: | twpsmet60sC3.b1 |
Description: | A lightning strike destroyed the upper wind sensor. |
Measurements: | twpsmet60sC3.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
11/14/2005 | 0453 | 11/15/2005 | 0050 |
Subject: | TWP/SMET/C3 - RH Values Artificially High |
DataStreams: | twpsmet60sC3.b1 |
Description: | Lightning strike caused RH readings to be higher than reasonable (130%). |
Measurements: | twpsmet60sC3.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
11/14/2005 | 0453 | 11/23/2005 | 0000 |
Subject: | TWP/SMET/C3 - Instrument failure |
DataStreams: | twpsmet60sC3.b1 |
Description: | A lightning strike caused a failure in the ORG. Rainfall was being continually recorded. |
Measurements: | twpsmet60sC3.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
12/01/2005 | 0000 | 08/24/2006 | 2359 |
Subject: | TWP/SMET/C3 - ORG data noisy due to degraded ground |
DataStreams: | twpsmet60sC3.b1 |
Description: | SMET Rain Data began to be noisy during December 2005 and the problem slowly became worse over time so that in February 2006 the ORG was reporting with a constant background value of around 0.10 mm/hr rain rate. ORG voltage showed a near constant value above the 85mV threshold. The ground for the ORG had become degraded and was lost due to corrosion. |
Measurements: | twpsmet60sC3.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
04/27/2006 | 2330 | 05/02/2006 | 0201 |
Subject: | TWP/SMET/C3 - Reprocessed: Lower windspeed sensor calibration error |
DataStreams: | twpsmet60sC3.b1 |
Description: | The lower anemometer was replaced but the calibration coefficients were not changed during this period. The data were reprocessed to apply the correct calibrations and the reprocessed data were archived in August 2008. |
Measurements: | twpsmet60sC3.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
06/27/2006 | 0115 | 06/27/2006 | 0344 |
Subject: | TWP/SMET/C3 - Data not representative |
DataStreams: | twpsmet60sC3.b1 |
Description: | The Anemometer readings were incorrect due to the tower being lowered for maintenance. |
Measurements: | twpsmet60sC3.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
03/12/2002 | 0000 | 09/26/2006 | 1435 |
Subject: | TWP/SMET/C3 - Reprocess: Tipping bucket rain gauge added |
DataStreams: | twpsmet60sC3.b1 |
Description: | A tipping bucket rain gauge was added to the SMET suite of instruments effective 20060926. Two new variables (count and rain amount) were added at the end of the twpsmet60sC1.b1 datastream. When reprocessing of this datastream occurs these variables will be added with -9999 (missing) as the value for dates prior to gauge installation. |
Measurements: | twpsmet60sC3.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
03/02/2007 | 1723 | 03/03/2007 | 1228 |
Subject: | TWP/SMET/C3 - Barometer Data Incorrect |
DataStreams: | twpsmet60sC3.b1 |
Description: | The barometer data was incorrect or missing due to water intrusion. |
Measurements: | twpsmet60sC3.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
03/03/2007 | 0056 | 03/03/2007 | 0123 |
Subject: | TWP/SMET/C3 - Water in enclosure |
DataStreams: | twpsmet60sC3.b1 |
Description: | Data became erratic and unreasonable after water intrusion into the enclosure. |
Measurements: | twpsmet60sC3.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
07/01/2007 | 0000 | 09/18/2007 | 2315 |
Subject: | TWP/SMET/C3 - Upper wind speed artificially slow |
DataStreams: | twpsmet60sC3.b1 |
Description: | The upper wind measurement was consistently slower by around 0.5 - 1 m/s than the lower wind measurement. The bearings on the upper wind measurement were binding. |
Measurements: | twpsmet60sC3.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
11/02/2007 | 1855 | 11/02/2007 | 2010 |
Subject: | TWP/SMET/C3 - ORG overestimated rainfall |
DataStreams: | twpsmet60sC3.b1 |
Description: | Optical rain gauge (ORG) measured approximately 10mm higher than two co-located tipping bucket rain gauges and a co-located disdrometer. The ORG is typically higher but usually not by an order of magnitude. |
Measurements: | twpsmet60sC3.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
01/05/2008 | 0000 | 02/27/2008 | 0315 |
Subject: | TWP/SMET/C3 - Upper Wind Sensor Data Questionable |
DataStreams: | twpsmet60sC3.b1 |
Description: | The wind_up vs. wind_low wind directions diverged, with the differences between the two eventually reached 45 degrees. The Upper sensor was found to be mis-aligned and loose. |
Measurements: | twpsmet60sC3.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
05/01/2004 | 0000 | 06/30/2010 | 2359 |
Subject: | TWP/SMET/C3 - Reprocess: ORG Data has very small rainrate values |
DataStreams: | twpsmet60sC3.b1 |
Description: | The ORG data is collected via analog signal and not digital. Therefore, we continuously collect data even when no rain is occurring. We also capture small events such as leaves, large bugs, dust, etc blowing through the measurement path. Because this discrete event occurs quickly the value is usually captured for 1 or 2 seconds. This value is then averaged to the minute producing rainrate on the order of .009 mm/hr or less. These values are not indicative of rain and should be removed from the record or summing over long periods can bias the climate record. We will reprocess the data to remove these small values. |
Measurements: | twpsmet60sC3.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
05/27/2008 | 1945 | 06/24/2008 | 0113 |
Subject: | TWP/SMET/C3 - Lower Wind Direction Intermittently Wrong |
DataStreams: | twpsmet60sC3.b1 |
Description: | The lower wind sensor cabling had a problem causing an intermittent connection for the wind direction data. |
Measurements: | twpsmet60sC3.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
07/08/2008 | 2045 | 07/17/2008 | 0144 |
Subject: | TWP/SMET/C3 - Upper wind speed data incorrect |
DataStreams: | twpsmet60sC3.b1 |
Description: | Beginning on 07/08, the upper wind sensor started reporting significantly lower wind speeds than the lower wind sensor. The cable connections weather proofing failed allowing corrosion to occur and increasing he resistance of the cables. This in turn lowered the wind speeds artificially. |
Measurements: | twpsmet60sC3.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
05/17/2004 | 2202 | 05/19/2004 | 0559 |
04/23/2006 | 2357 | 04/27/2006 | 0348 |
Subject: | TWP/SMET/C3 - Missing data |
DataStreams: | twpsmet60sC3.b1 |
Description: | Data are missing and unrecoverable. |
Measurements: | twpsmet60sC3.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
03/12/2002 | 0000 | 10/17/2008 | 0627 |
Subject: | TWP/SMET/C3 - Wind Speed data contain offset due to induced voltage |
DataStreams: | twpsmet60sC3.b1 |
Description: | The marine model of the RM Young wind sensor needs twisted pair shielded cable. The manufacturer did not originally supply the pigtail with twisted pair shielded cable. Use of twisted pair shielded cable for the rest of the cable run to the logger was also not specified. This caused an induced voltage in the wind speed line from the wind direction excitation. The induced voltage varied from sensor to sensor and probably changed anytime the cable was replaced or parts of the wind sensor were repaired or replaced. The induced voltage has been seen to vary from 0.15 m/s to as much as 1.08 m/s. |
Measurements: | twpsmet60sC3.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
01/27/2009 | 1850 | 01/30/2009 | 1535 |
Subject: | TWP/SMET/C3 - Reprocess: Station Pressure values reported in hPa instead of kPa. |
DataStreams: | twpsmet60sC3.b1 |
Description: | An incorrect program was entered into the datalogger. This program did not convert the station pressure from hPa to kPa. This made the values larger by a factor of 10 and caused the QC bit to be tripped. |
Measurements: | twpsmet60sC3.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
05/19/2004 | 0519 | 04/19/2005 | 0419 |
Subject: | TWP/SMET/C3 - Reprocess: Temperature data biased low |
DataStreams: | twpsmet60sC3.b1 |
Description: | Due to a datalogger problem, the temperature data were biased low by 2.13 degrees C. The data will be reprocessed. |
Measurements: | twpsmet60sC3.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
04/19/2005 | 0420 | 04/04/2009 | 0115 |
Subject: | TWP/SMET/C3 - Reprocess: Temperature Biased low by 1.06 Degrees |
DataStreams: | twpsmet60sC3.b1 |
Description: | The temperature of the SMET system was biased low by 1.06 Deg C due to a non-precision resistor being used int he measurement circuit. The data will be reprocessed. Saturation Vapor pressure and Vapor pressure will have to be reprocessed also. Add 1.06 degrees to the temperature data. Correct Sat Vap Press using the Buck approximation: Es = 6.1121exp((17.502*T)/(240.97 + T) where T is the temperature in C. Correct Vapor pressure using: E = (RH*Es)/100 |
Measurements: | twpsmet60sC3.b1:
|
Start Date | Start Time | End Date | End Time |
---|---|---|---|
09/30/2009 | 0045 | 09/30/2009 | 0500 |
Subject: | TWP/SMET/C3 - Tower Lowered for Maintenance |
DataStreams: | twpsmet60sC3.b1 |
Description: | The tower was lowered for annual anemometer changes. The wind data is suspect. |
Measurements: | twpsmet60sC3.b1:
|